| 1 | L1₹60,480Accepted-AOC B 235 MULLA COLONY B SECTOR KAROND BERASIA ROAD BHOPAL | BHOPAL | MADHYA PRADESH | 462001 | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹55,100+₹1,100 (2.04%)Rejected-AOC | L2 | Rejected-AOC Not lowest bidder | |
| 3 | L3₹56,000+₹2,000 (3.70%)Rejected-AOC | L3 | Rejected-AOC Not lowest bidder |
Tender Value
Refer Docs
Closing Date
11 Jun 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Dronachal
GE Dronachal, MES, Neori Hills D Top, Bhopal, M.P, 462038
Supply and fixing of Air condition
2022_MES_528142_1
3008/E-Qtn/22-23/JO/04/E3
Limited
Job Works
Works
30 days
GE Dronachal
Please refer Tender documents.
3 documents required · 3 mandatory
₹0
Exempted
14 Jun 2022
2 Jun 2022
13 Jun 2022
3 Jun 2022
11 Jun 2022
3 Jun 2022
Amount
Supply, install, testing and commissioning of 5 star rated air cooled hi wall split unit indoor/ outdoor inverter type airconditioners electric driven ( 250 volts, single phase, 50 Hz Supply) with energy efficient Rotary compressor, working on R-32 or superior enviornment - friendly refigerant, cordless remote operated, comprising of indoor unit, wall mounted, material of construction of indoor unit ABS, Nominal cooling capacity4500 Kcal/Hr, Minimum power consumption, Minimum room discharge airflow 700 Cum/ Hr guranteed cooling capacity (Min) 4275 Kcal/Hr outdoor unit, materialof Cabinet GI sheet 1.0 mm thickpowder coated, copper tubing, electric connection (Between indoor and outdoor unit located upto a maximum distance of 10 meters) and condensate water drainage arrangement etc complete of capacity 2 Ton complete all as specified and directed at site. Note:- (i) The outdoor unit shall be fixed on wall with standard bracket or fixed on roof / floor with proper MS stand. The cost is deemed to be included in the quoted rated. (ii) Additional length for copper tubing if required at site shall be supply & fix in respective items. (iii) GI Tubing for condensate water shall be measured and paid separately under respective item. Make: Voltas, Carrier, Bluestar
M/L for submain wiring with 2 Runs of 4.0 Sqmm single core PVC insulated staranded copper conductor FRLS cable drawn through rigid non metallin PVC conduit with one run of 4.0 Sqmm PVC insulated copper conductor FRLS cable as earth continuity conductor and necessary connections all as directed. Note: 2 run of 4 sqmm PVC insulated unsheathed copper and 1 run of 4 sqmm PVC insulated unsheathed copper conductor and 1 run 4 sqmm PVC insulated unsheathed copper conductor FRLS and 1 run of PVC conduit of 25 mm will be measured as single run.
Neelam Traders
AKASH ELECTRICAL
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_590268.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .