Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.9 LAccepted-AOC NEAR OLD CCS JUNGLIGHAT SRI VIJAYA PURAM 744 103 | SRI VIJAYA PURAM | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744103 | L1 | Accepted-AOC Lowest | |
| 2 | L2₹25.6 L+₹1.7 L (7.26%)Rejected-Finance 956 2 CHANDERSEKER ENTERPRISE OPP MARICAR HOSPITAL OLD CCS JUNGLIGHAT SOUTH ANDAMAN ANDAMAN NICOBAR 744103 | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744103 | L2 | Rejected-Finance Not Lowest | |
| 3 | L3₹26.3 L+₹2.4 L (10.2%)Rejected-Finance OPP MARUTI SERVICE CENTRE SARACHARMA POST SRI VIJAYA PURAM 744 105 | SRI VIJAYA PURAM | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744105 | L3 | Rejected-Finance Not Lowest | |
| 4 | L4₹26.9 L+₹3.0 L (12.4%)Rejected-Finance | L4 | Rejected-Finance Not Lowest | |
| 5 | L5₹28.0 L+₹4.1 L (17.3%)Rejected-Finance | L5 | Rejected-Finance Not Lowest |
Tender Value
Refer Docs
EMD Value
₹48,500
Closing Date
15 Dec 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE HADDO PORT BLAIR
GARRISON ENGINEER HADDO Military Engineer Services Haddo Post Port Blair Andaman and Nicobar 744102
PROVISION OF 01 X FLAG STAFF PLATFORM AND CONNECTING PATH AND CERTAIN MISC E/M SERVICES AT NSCB UNDER GE HADDO, PORT BLAIR
2022_MES_565521_1
8697/E8
Open Tender
Civil Works
Item Rate
180 days
HADDO PORT BLAIR
As per Tender documents
9 documents required · 9 mandatory
₹500
GE Haddo
₹48,500
Yes
19 Jan 2023
26 Nov 2022
22 Dec 2022
26 Nov 2022
15 Dec 2022
10 Dec 2022
28 Nov 2022 - 5 Dec 2022
Amount
M&L for surface excavation not exceeding 30 cm deep and averaging 15cm deep and getting out in hard/dense soil complete all as specified and as directed.
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 m in depth, for foundation etc., or for shafts, wells, cess pits, manholes, pier holes etc not exc. 10 Sqm on plan and n.exc. 1.5m in depth and getting out in hard/dense soil complete all as specified and as directed.
M&L for PCC (1:4:8) type D2 (using 40mm graded stone aggregate) as in foundation filling and mass concrete complete all as specified and as directed.
M&L for pre-cast cement concrete block masonry with solid blocks made up of (1:3:6) type C1 (using 20mm graded stone aggregate), masonry exceeding 10cm in width and setting in cement mortar (1:6) complete all as specified and directed.
M&L for rendering 15mm thick in CM (1:4) on fair faces of brick work or concrete, surfaces finished even and smooth without using extra cement complete all as specified and as directed.
M & L for Spreading and levelling of soil in layers n exc. 25 cm thick under floors or in foundations and well ramming and consolidation including watering complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm each as in soils complete all as specified and as directed.
Removal of surplus soil to a distance exc. 50m but n.exc 250m and deposited where directed at a level n. exc. 1.5 m above the starting point complete all as specified and directed.
M&L for reinforced cement concrete (1:1½:3) type A1 (using 20mm graded stone aggregate) as in foundations, including rafts, footings, foundation beams, plinth beams, bases for columns etc., basement slabs, under-reamed piles and mass concrete complete all as specified and as directed.
M&L for reinforced cement concrete (1:1½:3) type A1 (using 20mm graded stone aggregate) as in columns, pillars, piers, posts and struts complete all as specified and as directed.
M&L for use and waste of formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams and similar work vertical or to batter for rough finished surfaces of concrete flat complete all as specified and as directed.
M&L for use and waste of formwork to sides of sides of pillars, posts, struts, piers, columns and stanchions for rough finished surfaces of concrete flat complete all as specified and as directed.
M&L for Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
M&L for Mild steel TMT bars 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
M&L for 18 to 20mm thick granite slab (of any type), work (table rubbed and ploished) in cooking platform, window cill/jambs etc laid bedded over 15 mm thick CM (1:4) bedding & pointed in white / coloured cement to match coloured tiles including grinding and mirror polishing complete. (Note : Colour of granite shall be as approved by Engr-in-Charge)
M&L for preparation of newly plastered surfaces and applying two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm complete all as specified and as directed
S&F mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, length of bolt not exceeding 5 cm and dia of neck 12 to 20 mm complete all as specified and as directed.
M&L for hardcore of gauge n exc 63 mm , deposited, spread and levelled in layers not exceeding 15cm thick, watered and rammed to a true surface complete all as specified and directed.
M&L for 100mm thick PCC (1:4:8) type D2 (using 40mm graded stone aggregate) as in sub base of floors complete all as specified and as directed.
M&L for 25mm thick cement concrete 1:2:4 type B1 (using 20mm graded stone aggregate) as in sub base complete all as specified.
M&L for chequered cement concrete tiles 30cm x 30cm x 25mm thick, made of grey cement and pigments, machine pressed as in flooring, set, jointed and pointed in neat cement slurry laid over and including 20 mm thick screed bed in CM (1:4) complete all as specified and as directed.
Excavating in post holes (or similar holes) each not exceeding 0.5 Cum and getting out, returning, filling in and ramming earth or broken rubble mixed with earth around in layers not exc 25cm thick in hard/dense soil complete all as specified and as directed.
M&L for cement concrete (1:2:4) type B1 (using 20mm graded stone aggregate) as in foundations, filling and mass concrete complete all as specified and as directed.
S & F GI tubes, 80mm dia 'medium grade' galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors complete all as specified and directed.
S & F GI tubes, 50mm dia 'medium grade' galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors complete all as specified and directed.
M&L for non-skid ceramic coloured tiles 7 to 8 mm thick (square/ rectangular), area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, as in floors etc, laid over and including 15mm thick screed bed in CM (1:4), set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and as directed.
M&L for mild steel plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment Fe-410-W (Gde-E-250) Quality 'A' complete all as specified and as directed.
M&L for mild steel framed work such as grills, gratings, etc., with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars and similar work conforming to Fe-290 Gde E-165 complete all as specified and as directed.
M&L for preparation of new steel and iron surfaces of any description, not otherwise described, over 10cm in width or girth and applying two coats of synthetic enamel paint of first quality over a coat of red oxide zinc chrome primer complete all as specified and as directed.
M&L for LT XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 1100 volts grade, cross sectional area 3.5 core, 95 Sqmm laid in trenches/floors/ducts or fixed on poles/walls with suitable clamps/saddles or drawn through pipes etc., complete all as specified and as directed.
M&L for LT XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 1100 volts grade, cross sectional area 4 core, 25 Sqmm laid in trenches/floors/ducts or fixed on poles/walls with suitable clamps/saddles or drawn through pipes etc., complete all as specified and as directed.
M&L for LT XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 1100 volts grade, cross sectional area 4 core, 16 Sqmm laid in trenches/floors/ducts or fixed on poles/walls with suitable clamps/saddles or drawn through pipes etc.,complete all as specified and as directed.
M&L for LT XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 1100 volts grade, cross sectional area 2 core, 10 Sqmm laid in trenches/floors/ducts or fixed on poles/walls with suitable clamps/saddles or drawn through pipes etc., complete all as specified and as directed.
M&L for steel tubular swaged poles 410 SP-31 (9.00 metres long) conforming to IS:2713 (Part-I) 1980, welded with mild steel base plate of size 300x300x6mm thick, finial taper plug, bolts, nuts and washers including two coats of aluminium paint over a coat of red oxide primer complete all as specified and directed. Make: Kalinga tubes/The National Tubes Co./India tube & Co.
M&L for HDPE DWC (Double wall corrugated) pipe of size 120mm (Outer diameter) x 103mm (Inner diameter) along with connected accessories like couplers, bends, end caps etc., laid in trenches/floors/ducts or fixed on poles/walls for as in protection of LT/ HT cable complete all as specified and as directed. Make: Rex Poly Extrusion Ltd / Tirupati Plastomatics Pvt Ltd.
M&L for HDPE DWC (Double wall corrugated) pipe of size 50mm (Outer diameter) x 38mm (Inner diameter) along with connected accessories like couplers, bends, end caps etc., laid in trenches/floors/ducts or fixed on poles/walls for as in protection of LT/ HT cable complete all as specified and as directed. Make: Rex Poly Extrusion Ltd / Tirupati Plastomatics Pvt Ltd.
M&L for HDPE DWC (Double wall corrugated) pipe of size 40mm (Outer diameter) x 32mm (Inner diameter) along with connected accessories like couplers, bends, end caps etc., laid in trenches/floors/ducts or fixed on poles/walls for as in protection of LT/ HT cable complete all as specified and as directed. Make: Rex Poly Extrusion Ltd / Tirupati Plastomatics Pvt Ltd.
M&L for PCC (1:3:6) type C2 (using 40mm graded stone aggregate) as in foundation filling for poles/ stay assembly and mass concrete complete all as specified and as directed.
M&L for plain cement concrete (1:3:6) type C1 (using 20mm graded stone aggregate) as in copings, kneelers, apex stones, bed plates, kerbs, water troughs including weathering, slightly rounded or chamfered angles and throating including necessary form work, exposed surfaces of concrete finished even and smooth without using extra cement complete all as specified and as directed.
S&F LED street light fittings of high power LED, IP 66 protection and unique peanut lens to ensure uniform light distribution with LED of 70 Watts capacity, 220 V, 50 Hz and connected by 3 core 2.5 Sqmm multistranded copper conductor of suitable length complete all as specified and as directed. MAKE: C&S Cat NO: LTESSI70WLED / PHILIPS Cart part No.BRP409 LED 074 CW HE MR FG S1 PSU GR or equivalent in CROMPTON GREAVES/ HAVELLS/ LUKER
M&L for street light mounting bracket made up of 32mm dia galvanised steel tubing, medium grade, 1.20 metres long, bent to shape with inner angle not less than 120°, with and including necessary fixing clamps fabricated out of angle iron/flat iron of suitable size, bolts, nuts and washers as required and applying two coats of aluminium paint over a coat of red oxide primer complete all as specified and directed.
S&F of integral LED aviation light fittings comprising of aluminium housing with poly carbonate enclosure with red colour including all accessories and fixing the light fitting complete all as specified and directed. Make: Philips / Havells / CG
S&F Out door LT panel / LT pillar box of dimensions 1.3m x 1.2m x 0.6m size with following specifications. Fabrication Details : CPRI approved Main frame 3.15mm thick CRCA sheet, partition sheets / covers / doors of 3.15 mm thick CRCA sheet, gland plates 3.15 mm thick MS sheet (undrilled), all over body front and back cover with hinges and aldrops for locking arrangements duly 1 mm thick FRP coated all over external surfaces and 2 mm thick MS sheet for bus bar cover panel partitions and bottom cable entry covers duly painted with one coat of red oxide and two coats of synthetic enamel paint with control wiring to complete LT panel with 2.5 Sqmm FRLS copper cable and 6 A MCB's, meters, breaker control supply and indication lamps, base frame on ICMS channel with provision of incoming and outgoing cable entry at the bottom for outdoor installation, free standing floor mounted with degree of protection IP-65 and locking arrangements including taking down old unserviceable LT panel complete all as specified and as directed.
Bus bar details: Material shall be aluminum bus bar, sleeving heat shrinkable type, with bus bar sizes for phase 80x16mm aluminium flat, neutral 50x16mm aluminium flat and bus bar support of epoxy type. Painting Details : Pillar box shall be powder coated and painted with two coats of synthetic enamel spray paint over a coat of redoxide primer and marking of details of capacity/ rating/ incoming/ outgoing/ danger notice board in capital English alphabets with red colour radium sticker of required size. Accessories for Pillar Box: (i) 0-500V Digital voltmeter - 01 No (Flush type) (ii) 0-500A Digital Ammeter - 01 No (Flush type) and (iii) Indication Lamps (LED) RYB - Set of 03 Nos. MAKE: L&T / BINAY/ ELMEASURE (iv) Incomer:- 250A, 4 pole, Changeover switch of Make:L&T, Cat No. CM98060OOO -1 No. (v) Outgoing:- (i) 100A, 3 pole, MCCB, 36kA of Make: L&T, Cat No. CM90678OOLO -3 Nos. (ii) 63A,3 pole,MCCB, 30kA of Make: L&T, Cat No. CM97894OOJ2 -3 No. NOTES: (i) The unit rate quoted is deemed to include the cost of MCCBs, Volt meter, Ammeter, Indication lamps and connected wiring with necessary spreader links, lugs, glands and connecting of cables as per site conditions and complete all as specified and as directed. (ii) The unit rate quoted deemed to include for cost of breaking the existing Jetty surface, if any and making good the disturbed surfaces to match with existing surfaces. (iii) Drawings must be approved by Engineer-in-Charge before fabrication of LT Panel.
M&L for earthing complete with GI earth plate electrode of size 600mmx600mmx6mm thick, 40mm bore medium grade (Steel pipe) buried directly in ground (earth pit not less than 2.25m deep below the normal ground level) with top edge of the earth plate not less than 1.5m below normal ground level connected to 32x6mm GI earth strip as earth lead connected by means of bolts, nuts, washers and check nuts made out of galvanised iron or steel all as shown on electrical plate No. 3 of SSR Part-I connected to common earth dolly including testing on completion complete all as specified and directed. NOTES: 1) The unit rate shall also include for earth work in any type of soil, PCC (1:3:6) type C1 chamber, pre-cast RCC (1:2:4) type B-1 using 20mm graded stone aggregate cover 50mm thick reinforced with TMT bars 8mm dia @ 100mm c/c both ways, funnel with watering pipe 20mm dia medium grade, GI protection pipe light grade 40mm dia and wire mesh complete in addition to item No. 1(a) to (e) of preamble (notes) under sub-heading earthing, specified in SSR Part-II. 2) Earthing lead and GI protection pipe beyond 7.5m will be measured and paid separately.
M&L for dismantling of cable termination attatched to the alternator to the 125KVA DG set and removal and earth connection and body of DG set including supporting pipe / exhaust pipe so as to facilitate the shifting and shifting of 125KVA DG set to the distance of bout 150RM complete all as specified and directed.
S & F GI tubes, 80mm dia 'medium grade' galvanised, with all fitting laid in trenches complete all as specified and directed.
S & F GI tubes, 40mm dia 'medium grade' galvanised, with all fitting laid in trenches complete all as specified and directed.
S & F GI tubes, 50mm dia 'medium grade' galvanised, with all fitting laid in trenches complete all as specified and directed.
S & F GI tubes, 25mm dia 'medium grade' galvanised, with all fitting laid in trenches complete all as specified and directed.
S&F 25mm dia gun metal, globe or gate valves, ISI marked high pressure with iron wheel head, screwed both ends for iron or CPVC pipe complete all as specified and as directed. Make: Zoloto / Kartar / Venus / Laxmi / Qinn
S&F 50mm dia gun metal, globe or gate valves, ISI marked high pressure with iron wheel head, screwed both ends for iron or CPVC pipe complete all as specified and as directed. Make: Zoloto / Kartar / Venus / Laxmi / Qinn
S&F cast iron sluice valve, 80mm size or bore, class PN 1.6, ISI marked, heavy duty with brass spindle, operating wheel, flanged on both ends along with suitable new rubber packing (gasket), stainless steel bolts, nuts & washers and necessary modifications if required for fixing in location complete all as specified and as directed. MAKE: KIRLOSKAR/UPADHYAY/ZOLOTO/LEADER/KARTAR
S&F foot valve, brass, 40 mm bore, screwed and threaded, with strainer and jointing with the existing suction pipe line complete all as specified and as directed. MAKE: KIRLOSKAR/KARTAR/LEADER/ZOLOTO
S&F foot valve, brass, 25 mm bore, screwed and threaded, with strainer and jointing with the existing suction pipe line complete all as specified and as directed. MAKE: KIRLOSKAR/KARTAR/LEADER/ZOLOTO
S&F rotational moulded polyethylene (HDPE) water storage tanks, triple layered, ISI marked (cylindrical vertical with closed top), 1000 litres capacity, hoisted and fixed in position including 40mm/ 25mm dia spouts for connecting inlet,outlet,over flow and wash out pipes complete all as specified and as directed.
Supply, install and commissioning of cast iron centrifugal monoblock pumpset of 5 HP capacity having discharge of minimum of 11 LPS and head of 22 meter operating voltage of 415V and 50 Hz AC supply complete all as specified and directed. Make : Kirloskar Brothers Ltd / CG / KSB
M&L for disconnecting PVC water tank of capacity 10000 Ltrs and shifting to a location at a distance for 300RM and reshifting the same complete all as specified and as directed.
CHANDER SEKER ENTERPRISE
M/s Ramesh Lal
V KARTHICK
CARTWHEEL CONSTRUCTION
A PALANI
M/s K Moorthi
SHUBHAM SHANKAR GAIKWAD
LOOK UP ENTERPRISES
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .