Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.8 LAccepted-Finance | L1 | Accepted-Finance as per board proceeding | |
| 2 | L2₹20.0 L+₹1.2 L (6.54%)Rejected-Finance | L2 | Rejected-Finance as per board proceeding | |
| 3 | Rejected-Technical | - | Rejected-Technical all documents are not submitted |
Tender Value
Refer Docs
EMD Value
₹44,357
Closing Date
20 Feb 2021, 4:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Assistant Commandant 5th Bn ITBP
5th Bn ITBP Leh Ladakh
Supply and Erection of 03 Nos FRP Shelter for SOs accommodation at Murgo post of 5th Bn. ITB Police Leh- Ladakh (U.T)
2021_ITBP_616443_1
No. ITBP/5 Bn/ENGR/ TENDER/W-21/2021- 169-73
Open Tender
Civil Works
Item Rate
180 days
Murgo Post AOR of 05th Bn ITBP Leh Ladakh
Please refer Tender documents
8 documents required · 8 mandatory
₹0
₹44,357
4 Mar 2021
13 Feb 2021
22 Feb 2021
13 Feb 2021
20 Feb 2021
13 Feb 2021
13 Feb 2021 - 20 Feb 2021
90 days
Amount
(A) FOR CONSTRUCTION OF PLINTH
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 Sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m: All kinds of soil.
Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering - All work upto plinth level 1 :1.5:3 (1 Cement : 1.5Coarse sand : 3 graded stone aggregate 20 mm nominal size)
Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering - All work upto plinth level 1:5:10 (1 Cement : 5Coarse sand : 10 graded stone aggregate 40 mm nominal size)
Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 Cement : 6 coarse sand : 12 graded stone aggregate 20mm nominal size) at plinth level with :Cement mortar 1:6 (1 Cement : 6 coarse sand)Cement should be used of ACC/Ambuja/ L&T/ Birla make.
20 mm cement plaster of mix : 1:6 (1 cement: 6 fine sand)
Reinforced cement concrete work in walls ( any thickness), including attacked pilasters, butresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. up to floor five level excluding cost of centering, shuttering, finishing and reinforcement : 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) For Septic Tank Cover/Slab.
centering and shuttering including strutting, propping etc. and removal of form for :Lintels, beams, plinth beams, girders, breassumers and cantilevers. For Septic Tank Cover/Slab.
Reinforcement for RCC work including straightening, cutting, bending, placing in position and binding all complete.Thermo-Mechanically treated bars. For Septic Tank Cover/Slab.
SUPPLY OF FRP HUTS
FRP shelter (08men) curved panel type FRP shelters of size-4.80x4.80m with entry and toilet chamber of size 2.40x1.20m with phenomic foam insulation and a height of 2.44m and its peak,each shelter has a chamber of 3.60 m length and entry chamber of 3.60m length and entry chamber 1.2m width, two doors, five fixed windows & 3 sliding windows.
Erection of FRP shelter(08nos) curved panel type FRP shelter of size 4.80x4.80m with entry and toilet chamber of size 2.40x1.20m with phenomic foam insulation and a height of 2.44m and its peak, each shelter has a chamber of 3.60 m length and entry chamber of 3.60m length and entry chamber of 1.20m width. Two doors five fixed windows and 3 sliding windows.
Transporation of FRP shelter(08 men) curved panel type FRP shelters of size 1.80x1.80mtr( F.O.R at Murgo Post)
ELECTRICAL WORK
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc as required.
Wiring for light/ power plug with 2X4 sq. mm FR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No 4 sq. mm FR PVC insulated copper conductor single core cable for loop earthing as required.
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
5/6 amps switch
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
15/16 amp switch
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
3 pin 5/6 amp socket outlet
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
6 pin 15/16 amp socket outlet
Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.
3 Module
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Single pole
Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.
18 watt Tube light
CHITRA CABINET WORKS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .