Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.1 LAccepted-AOC E 82 HQ CE A N Z PB POST BOX NO 687 LILLYPUR NEAR MES GURUDWARA HADDO POST SRI VIJAYA PURAM 744 102 | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744102 | L1 | Accepted-AOC Lowest | |
| 2 | L2₹27.9 L+₹30,813.50 (1.12%)Rejected-Finance | L2 | Rejected-Finance Not Lowest | |
| 3 | L3₹28.4 L+₹79,162.50 (2.87%)Rejected-Finance | L3 | Rejected-Finance Not Lowest | |
| 4 | L4₹29.3 L+₹1.7 L (6.10%)Rejected-Finance DAIRY FARM JUNCTION VIJAY BAUGH ROAD SRI VIJAYA PURAM 744 103 | SRI VIJAYA PURAM | SOUTH ANDAMAN | ANDAMAN AND NICOBAR ISLANDS | 744103 | L4 | Rejected-Finance Not Lowest | |
| 5 | L5₹29.3 L+₹1.7 L (6.29%)Rejected-Finance | L5 | Rejected-Finance Not Lowest |
Tender Value
₹36.4 L
EMD Value
₹72,780
Closing Date
21 Aug 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer Haddo Port Blair
GARRISON ENGINEER HADDO Military Engineer Services Haddo Post Port Blair Andaman and Nicobar 744102
ADDITION / ALTERATION TO P-73 NAVIK INSTITUTE AT COAST GUARD AND CERTAIN SANCTIONED WORKS AT NSRY UNDER GE HADDO
2020_MES_364850_1
8486/GE/H/PB
Open Tender
Civil Works
Item Rate
180 days
GE Haddo Port Blair
D a(i) and b(i)
9 documents required · 9 mandatory
₹500
Yes
GE Haddo
₹72,780
Yes
18 Sept 2020
28 Jul 2020
24 Aug 2020
28 Jul 2020
21 Aug 2020
8 Aug 2020
29 Jul 2020 - 6 Aug 2020
60 days
Amount
Demolition of cement concrete (unreinforced) in ground floors and pavings not exceeding 15 cm thickness (below or above ground level) complete all as specified and as directed.
Demolition of PCC block masonry, built in cement mortar including all quoins, arches, pillars etc., but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and as directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed.
Dismantling stone slabs and tiles of any description or thickness in floors, aprons, risers of steps, skirting, dado etc., laid bedded and pointed in any mortar mortarcomplete all as specified and as directed.
Dismantling structural steel work as in frame work of any description complete all as specified and as directed.
Dismantling plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings etc., complete all as specified and as directed.
Dismantling ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets complete all as specified and as directed.
Taking down chowkhats or frames with shutters (without taking off shutters from the frames), area exceeding 1.5 Sqm but not exceeding 4.0 Sqm each complete all as specified and as directed.
Taking down chowkhats or frames with shutters (without taking off shutters from the frames), area not exceeding 1.5 Sqm each complete all as specified and as directed.
Taking up or down 15mm dia steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and as directed.
Taking up or down 20mm dia steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and as directed.
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 m in depth, for foundation etc., or for shafts, wells, cess pits, manholes, pier holes etc not exc. 10 Sqm on plan and n.exc. 1.5m in depth and getting out in soft/loose soil complete all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm each as in soils complete all as specified and as directed.
Removing excavated material (soils) to a distance not exceeding 50 metres and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and as directed.
M&L for pre-cast cement concrete block masonry with solid blocks made up of (1:3:6) type C1 (using 20mm graded stone aggregate), masonry exceeding 10cm in width and setting in cement mortar (1:6) complete all as specified and directed.
M&L for PCC (1:4:8) type D2 (using 40mm graded stone aggregate) as in filling in sunken floors complete all as specified and as directed.
Material and labour for providing PCC 1:2:4, type B0, using 12.5 mm graded stone aggregate as in sunken floor / roof padding and similar work including water proofing compound all as specified and directed. Note :- WPC shall be measured and paid seperately as suppy only.
M&L for plain cement concrete (1:2:4) type B1 (using 20mm graded stone aggregate) as in lintels upto 1.5m clear span, cills and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs including weathering, slightly rounded or chamfered angles and throating including necessary form work, exposed surfaces of concrete finished even and smooth without using extra cement complete all as specified and as directed.
M&L for reinforced cement concrete (1:2:4) type B1 (using 20mm graded stone aggregate) as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs, cooking platforms and in shelves and the like including necessary formwork complete all as specified and as directed.
Supply only integral water proofing compound.
M&L for cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring etc., and making good to match with existing surfaces, cutting not exc 10 cm girth in PCC block masonry/RCC complete all as specified and directed.
S&F solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. square tube as per specification & drawing, fixed in opening complete all as specified and as directed.
S&F factory made solid PVC moulded door shutter with particle board core, 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick moulded prelaminated PVC sheet on the front face & 2mm plain colour PVC sheet on back face as per specification & drawing fixed to door frame complete all as specified and as directed.
S&F 150mm long aluminium anodised, barrel tower bolts of extruded section complete all as specified and as directed.
S&F 100mm size butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin, anodised, type B-21 complete all as specified and as directed.
S&F 150mm size extruded aluminium alloy handles, fabricated type, anodised complete all as specified and as directed.
S&F Harrison rails (curtain rails), anodised aluminium alloy with fixing brackets, stops, rollers etc., in repairs complete all as specified and as directed.
S&F door closer, aluminium (extruded section body), hydraulically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed with screws complete all as specified and as directed.
Supply only aluminium expanded metal fly proof mesh, cut to required size and shape, with 0.45mm nominal dia of wire and average width of aperture 1.40mm complete all as specified and as directed.
M&L for Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
M&L for Mild steel TMT bars 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
M&L for mild steel rolled sections as in main and cross beams, hip and jack rafters, purlins where connected to common rafters and running rails and guides for sliding doors, fixed with angle cleats or other connecting plates etc., conforming to Fe-290 (Gde E-165) complete all as specified and as directed.
M&L for mild steel rolled sections as in post built up of one beam / channel or angle section with flange plates, caps, bases, splices, angle brackets, cleats and other connections conforming to Fe-410-W (Gde E-250) complete all as specified and as directed.
M&L for mild steel plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment conforming to Fe-410-W (Gde-E-250) Quality 'A' complete all as specified and as directed.
M&L for mild steel roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (beam, tee, angle, channel or flat sections) including distance pieces, cleats etc., conforming to Fe-410-W (Gde E-250) Quality 'A' complete all as specified and as directed.
S&F aluminum flat iron wind ties of any size and thickness fixed with self tapping screws for fixing roofing sheets complete all as specified and as directed. NOTES: The self tapping screw shall be of adequate length to drive into complete thickness of purlin/rafter etc., and shall be fixed using neoprene and EPDM washers.
M&L for stainless steel hollow sections circular/ square/rectangular in shape and any size and thickness, grade AISI-316 type (Austenitic anti-corrosive in nature) as in railings/grills/designer work including post top cap, bottom plate, cutting, bending, seamless welding and fixed in any location complete all as specified and as directed.
M&L for powder coated anodised aluminium partition, window and door/ventilator with frame and shutters and grill fully or partly glazed, sliding/openable/fixed fully glazed and panels fixed with panels inserts 12 mm thick pre-laminated particle board/sheet glass including necessary jointing cleats, glazing clips, rubber beading, neoprene packing, anodised aluminium snap beading, screws, anodized aluminium fittings such as handles, aluminium butt hinges, aluminium tower bolts etc. The size of aluminium section shall be all as specified in relevant IS Code and SSR Part-I complete all as specified and as directed. NOTES: (i) Supply only floor spring, glass, Imax hinges, SS friction hinges, particle board, aluminium fly proof mesh, solar control film will be measured and paid separately under relevant items of this BOQ. (ii) Weight of aluminium section only shall be accounted for the purpose of payment. However unit rate quoted shall be deemed to include for cost of rubber beading, neoprene packing, fittings such as handles, butt hinges, tower bolts, rollers for sliding windows, locking arrangement and fixing only of panel inserts of glass/ particle board/aluminium fly proof mesh etc. (iii) Weight of aluminium handle, butt hinges, tower bolts shall not be accounted for payment purpose.
M&L for anodised aluminium snap grid frame work for false ceiling with size of grid 605mm x 605mm all as specified in SSR Part-I 2009, hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat iron 40x3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long including cutting, drilling, jointing etc., 6mm thick non-asbestos fibre cement building design boards fixed or laid/ inserted to aluminium frame work with screws and applying two coats of distemper oil emulsion over a coat of primer complete all as specified and as directed.
M&L for false ceiling made out of 6 mm thick non asbestos fibre cement building boards including for any sunk or raised moulding with 25mm long self drilling/tapping screws having Philips head with jointing compound and 48 mm wide fibre tape to provide seam less finish and including GI frame work comprising of GI perimeter channel 0.55 mm thick with two unequal flanges of 20 mm and 30 mm, and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm c/c / intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm c/c with GI cleats and steel expansion fasteners with and including ceiling section (not exceeding 1.2 m length) of 0.55 mm thick having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm c/c including hangers 6 mm dia GI adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40x3 mm size, 60 mm long & expansion hold fasteners 12.5 mm dia, 40 mm long and finally applying two coats of oil bound distemper with roller finish over a coat of primer complete all as specified and as directed.
S&F pre-painted zinc coated aluminum sheet (Galvalume) GI based trapezoidal profile steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed. NOTES: The self tapping screw shall be of adequate length to drive into complete thickness of purlin/rafter etc., and shall be fixed using neoprene and EPDM washers. Penetration and laps in sheet shall be sealed by using proper sealant profile. HDPE fillers shall be provided wherever required to close voids between sheets, sheet & fasteners etc., as per SSR Part-I 2009 complete.
S&F pre-painted zinc coated aluminum sheet (Galvalume) GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall/valley gutters, fixed with self tapping screws including scoffolding for a height upto 12.0 metres complete all as specified and as directed. NOTES: The self tapping screw shall be of adequate length to drive into complete thickness of purlin/rafter etc., and shall be fixed using neoprene and EPDM washers. Penetration and laps in sheet shall be sealed by using proper sealant profile. HDPE fillers shall be provided wherever required to close voids between sheets, sheet & fasteners etc., as per SSR Part-I 2009 complete.
Material and labour for preparing plastered surfaces and applying primer @ 0.30/litre per Sqm, tack coat of 1.2Kg per sqm bitumen 85/25 and, laying 3.0mm thick polyster reinforced APP modified water proofing membrane weighing not less than 3.6 Kg per Sqm by torch application, one coat of bitumen based aluminium heat resistant paint @0.30 ltr/Sqm over APP membrane including removal of existing water proofing treamant on roof, sunken slabs, edges and vertical surfaces complete all as specified and directed.
Supply only 9mm thick prelaminated particle board, interior grade, prelaminated both sides with decorative choice lamination complete all as specified and as directed.
M&L for 25mm thick PCC (1:2:4) type B0 (using 12.5mm graded stone aggregate) as in levelling course, sub base of floors and pavings complete all as specified and as directed.
Material and labour for Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust etc., complete all as specified and directed.
M&L for 20mm thick granite work (of any type and shade as approved) table rubbed and polished as in steps, jambs, pillars, window cills, cooking platforms, wash basin counters and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite laid over and including 15mm thick cement mortar (1:4) bedding and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing, rounding (chamfering) the edges complete all as specified and directed.
M&L for non-skid ceramic coloured tiles 7 to 8 mm thick (square/ rectangular), area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, as in floors etc, laid over and including 15mm thick screed bed in CM (1:6), set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and as directed.
M&L for non-skid ceramic coloured tiles 7 to 8 mm thick (square/ rectangular), area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, for work on vertical surfaces such as skirting, dados and risers to steps etc., including 10mm thick backing coat in CM (1:4), set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and as directed.
M&L for non-skid ceramic coloured tiles 7 to 8 mm thick (square/ rectangular), area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, as in floors etc, laid over and including 15mm thick screed bed in CM (1:6), set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and as directed.
M&L for glazed ceramic designed coloured tiles in vertical surfaces using size of tiles 450x350x7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match with colour of tile with and including 10mm thick backing coat in CM (1:4), set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and as directed.
M&L for vitrified ceramic coloured tiles 10 mm thick (square/ rectangular) of approved shade, area of each tile not exceeding 0.36 Sqm as in floors etc., laid over and including 15mm thick screed bed in CM (1:4), set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and as directed.
M&L for vitrified ceramic coloured tiles 10 mm thick (square/ rectangular) of approved shade, area of each tile not exceeding 0.36 Sqm, for work on vertical surfaces such as skirting, dados and risers to steps etc., including 10mm thick backing coat in CM (1:3), set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and as directed.
Taking down cement plaster of any description on brick or stone walls etc., including raking out joints, hacking for key, scrubbing down with water etc., and removing the debris outside MD land complete all as specified and as directed.
M&L for rendering 15mm thick in two coats 5mm thick in CM (1:4) mixed with integral water proofing compound @ 3% by weight of cement over 10mm thick in CM (1:6) on fair faces of brick work or concrete, surfaces finished fair and even complete all as specified and as directed. NOTE: Water proofing compound will be measured and paid separately under relevant item of this schedule.
M&L for rendering 10mm thick in CM (1:6) on fair faces of brick work or concrete, surfaces finished even and smooth without using extra cement complete all as specified and as directed.
M&L for 12mm thick plaster on RCC roof slab in CM (1:4) mixed with integral water proofing compound @ 3% by weight of cement complete all as specified and as directed. NOTE: Water proofing compound will be measured and paid separately under relevant item of this schedule.
M&L for preparation of newly plastered surfaces of walls of any description and applying two coats of distemper oil emulsion over a coat of primer including levelling the undulations with cement putty complete all as specified and as directed.
M&L for preparation of newly plastered surfaces of external walls of any description and applying two coats of weather proof antifungal (exterior grade) acrylic emulsion over a coat of primer from the same manufacturer complete all as specified and as directed.
M&L for preparation of old plastered surfaces of walls by complete removal of existing treatment by scraping, washing, cleaning etc., and applying two coats of distemper oil emulsion over a coat of primer including 3mm thick wall care putty and levelling the undulations with cement putty complete all as specified and as directed.
Supply only 4.0 mm thick sheet glass, ordinary quality in squares exceeding 0.5 Sqm in each pane complete all as specified and as directed.
Supply only 5.5 mm thick sheet glass, ordinary quality in squares exceeding 0.5 Sqm in each pane complete all as specified and as directed.
Supply only 4.0 mm thick figured glass pin headed type, ordinary quality in squares not exceeding 0.5 Sqm in each pane complete all as specified and as directed.
Supply only Solar control film 25 micron reflective type complete all as specified and as directed.
S&F aluminium grill of approved pattern, anodised powder coated, cut to required size and shape, fixed in postion with aluminium beading & frame made of aluminium F-section fixed to aluminium windows/ventilators complete all as specified and as directed.
M&L for preparation of new steel and iron surfaces of any description, not otherwise described, over 10cm in width or girth and applying two coats of synthetic enamel paint of first quality over a coat of red oxide zinc chrome primer complete all as specified and as directed.
S&F 15mm bore unplasticised PVC pipes of pressure rating 10 Kgf/cm² including fittings, fixed complete to walls, ceilings or in floors etc., (including concealing, if required) and to any type of pipe complete all as specified and as directed.
S&F 25mm bore unplasticised PVC pipes of pressure rating 10 Kgf/cm² including fittings, fixed complete to walls, ceilings or in floors etc., (including concealing, if required) and to any type of pipe complete all as specified and as directed.
Dismantling PVC (SWR)/ cast iron pipes of 110mm dia in any position alongwith all fittings and fixtures by removing at joints complete all as specified and as directed.
Dismantling PVC (SWR)/ cast iron pipes of 75mm dia in any position alongwith all fittings and fixtures by removing at joints complete all as specified and as directed.
S&F 110mm bore PVC (SWR) pipes single socketed, in any length pipes single socketed, in any length with rubber ring joints fixed to walls using synthetic rubber adhesive cement solvent complete all as specified and as directed.
S&F 75mm bore PVC (SWR) pipes single socketed, in any length pipes single socketed, in any length with rubber ring joints fixed to walls using synthetic rubber adhesive cement solvent complete all as specified and as directed.
Fixing only 110mm bore PVC (SWR) pipes single socketed, in any length pipes single socketed, in any length with rubber ring joints fixed to walls using synthetic rubber adhesive cement solvent complete all as specified and as directed.
Fixing only 75mm bore PVC (SWR) pipes single socketed, in any length pipes single socketed, in any length with rubber ring joints fixed to walls using synthetic rubber adhesive cement solvent complete all as specified and as directed.
S&F PVC (SWR) bends any radius, diameter of outlet 110 mm complete all as specified and as directed.
S&F PVC (SWR) bends any radius, diameter of outlet 75 mm complete all as specified and as directed.
S&F PVC (SWR) vent cowl of diameter 110 mm complete all as specified and as directed.
S&F PVC (SWR) vent cowl of diameter 75 mm complete all as specified and as directed.
S&F PVC (SWR) branch piece singl Y of radius equal or unequal, diameter of outlet 75 mm complete all as specified and as directed.
S&F PVC (SWR) multi floor trap with grating including jointing with solvent cement, diameter of outlet 75mm, complete all as specified and as directed.
S&F rotational moulded polyethylene water storage tanks, triple layered, ISI marked (cylindrical vertical with closed top), 1000 litres capacity, hoisted and fixed in position all as specified in SSR Part I, 2009 including 25mm dia or bore PTMT ball valve high pressure with epoxy coated aluminium rod & high density plastic ball (minimum weight 455 gms) screwed for iron pipe, provision of 40mm/25mm dia spouts for connecting inlet, outlet, over flow and washout pipes including taking down the existing tank complete all as specified and as directed.
S&F bib taps, brass, 15mm dia, chromium plated, fancy type, with crutch or butterfly handle, screwed down, screwed for iron pipe or brass ferrule fixed in repairs complete all as specified and as directed. MAKE: JAQUAR Cat part No. FLR-5047N)
S&F angular stop cock, 15mm dia, cast copper alloy, chromium plated, fancy type, with crutch or butterfly handle, with long shank and cup (concealed type) screwed down, screwed both ends for iron pipe or for unions, fixed in repairs complete all as specified and as directed. MAKE: JAQUAR Cat part No. FLR-5053N
M&L for vitreous China squatting pan, ‘Orissa’ pattern, size 580 x 440 mm white, with integral foot rests, P or S trap including provision of lime concrete bedding including connecting to flushing cistern / pipe and making good disturbed portion to match existing surface fixed in repairs complete all as specified and as directed.
M&L vitreous china ware wash basin white, counter top oval shape and size of 550m x 400mm, including 32 mm CP waste coupling, chain and plug, waste fittings, union and waste pipe 32mm dia of required length and all necessary inlet, out let connections in repairs complete all as specified and as directed.
M&L for vitreous China bowl urinal flat back, of size 465x355x265 mm white (minimum) with grating and union for discharge pipe including providing and fixing plugs, buttiing urinal against wall in cement mortar (1:2), securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in white cement with and including 32mm dia waste pipe in low density polyethylene (LDPE) of pressure rating 6 kgf/sqcm of 1.0 metre length, PVC connections 15mm size with PTMT nuts of length 450mm, concussive push button taps 15mm dia or bore, cast copper alloy, screwed for iron pipe, urinal spreader of PTMT any colour for fixing with 15 mm dia pipe (minimum weight 60gms), fixed in repairs complete all as specified and as directed.
S&F pillar tap, brass, 15mm dia, chromium plated, fancy type with capstan heads, screwed down, high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe, fixed in repairs complete all as specified and as directed.
M&L for PVC valveless, syphonic action type, flushing cistern, 10 litre capacity, low level, white, with inlet, ball valve, float and handle including brackets, fixed in repairs complete all as specified and as directed.
S&F tubular towel rail, brass, chromium plated, 20mm dia, 60 cm long between flanges, fixed in repairs complete all as specified and as directed. MAKE: JAQUAR Cat part No. ACN-1111NM)
S&F toilet paper holder, brass, chromium plated, fixed in repairs complete all as specified and as directed. MAKE: JAQUAR Cat part No. ACN-1153N)
S&F health faucet, brass, chromium plated with 8mm dia, 1.0 m long flexible tube, screwed for iron pipe or for brass ferrule 15mm dia of bore fixed in repairs complete all as specified and as directed. MAKE: JAQUAR Cat part No. ALD-573)
M&L for PVC connections 15mm size with PTMT nuts of length 600mm, fixed in repairs complete all as specified and as directed.
M&L for Point wiring complete with 1.5 Sqmm (nominal area) single core, PVC insulated unsheathed, FRLS cable, 1100 volts grade, multistranded copper conductor (with colour coding of Red/Blue/Yellow for phase and Black for neutral), drawn through and including rigid non metallic PVC conduit of suitable size (not less than 20mm dia) medium grade and conduit accessories concealed in walls/ceilings etc., including provision of PVC insulated 1.5 Sqmm FRLS cable with copper conductor green in colour for earth continuity and connected to common earth dolly and sunk in modular type pressed steel terminal boxes of suitable modules made out of 1.6mm thick MS sheet duly painted with two coats of anti-corrosive paint all over and modular cover plates with frames on top for suitable modules on top for housing switches, sockets etc., all as specified and as directed for ONE FAN point controlled by one, one way 6 Amps modular switch.
M&L for Point wiring complete with 1.5 Sqmm (nominal area) single core, PVC insulated unsheathed, FRLS cable, 1100 volts grade, multistranded copper conductor (with colour coding of Red/Blue/Yellow for phase and Black for neutral), drawn through and including rigid non metallic PVC conduit of suitable size (not less than 20mm dia) medium grade and conduit accessories concealed in walls/ceilings etc., including provision of PVC insulated 1.5 Sqmm FRLS cable with copper conductor green in colour for earth continuity and connected to common earth dolly and sunk in modular type pressed steel terminal boxes of suitable modules made out of 1.6mm thick MS sheet duly painted with two coats of anti-corrosive paint all over and modular cover plates with frames on top for suitable modules on top for housing switches, sockets etc., all as specified and as directed for TWO LIGHT point controlled by one, one way 6 Amps modular switch.
M&L for Point wiring complete with 1.5 Sqmm (nominal area) single core, PVC insulated unsheathed, FRLS cable, 1100 volts grade, multistranded copper conductor (with colour coding of Red/Blue/Yellow for phase and Black for neutral), drawn through and including rigid non metallic PVC conduit of suitable size (not less than 20mm dia) medium grade and conduit accessories concealed in walls/ceilings etc., including provision of PVC insulated 1.5 Sqmm FRLS cable with copper conductor green in colour for earth continuity and connected to common earth dolly and sunk in modular type pressed steel terminal boxes of suitable modules made out of 1.6mm thick MS sheet duly painted with two coats of anti-corrosive paint all over and modular cover plates with frames on top for suitable modules on top for housing switches, sockets etc., all as specified and as directed for ONE 3 PIN 6A SOCKET OUTLET point controlled by one, one way 6 Amps modular switch on independent board.
M&L for Point wiring complete with 4.0 Sqmm (nominal area) single core, PVC insulated unsheathed, FRLS cable, 1100 volts grade, multistranded copper conductor (with colour coding of Red/Blue/Yellow for phase and Black for neutral), drawn through and including rigid non metallic PVC conduit of suitable size (not less than 20mm dia) medium grade and conduit accessories concealed in walls/ceilings etc., including provision of PVC insulated 4.0 Sqmm FRLS cable with copper conductor green in colour for earth continuity and connected to common earth dolly and sunk in modular type pressed steel terminal boxes of suitable modules made out of 1.6mm thick MS sheet duly painted with two coats of anti-corrosive paint all over and modular cover plates with frames on top for suitable modules on top for housing switches, sockets etc., all as specified and as directed for ONE 16A SOCKET OUTLET point controlled by one, one way 16 Amps modular switch on independent board.
S&F Modular socket 6A/16A - 2/3 pin combined 2 module complete all as specified and as directed.
S&F modular switch, one way, one module, single pole, 16 / 20 Amps complete all as specified and as directed.
S&F modular switch, one way, one module, single pole, 6 / 10 Amps complete all as specified and as directed.
S&F Modular socket, 6/10 Amp, 2/3 pin combined 2 module complete all as specified and as directed.
M&L for ceiling rose, three terminal, 65x20mm size, PVC/Polycarbonate, insulated body, 6A, 240 volts complete all as specified and as directed.
S&F MCB DB, SPN, 8-way, vertical type, double door, 240 Volts with 200 Amps rated bus bar, IP-43 protection, shrouded neutral bus bar, cement spill protector, concealed in wall and making good disturbed surfaces to match with surrounding surface complete all as specified and as directed.
S&F MCB, DP, "C" series, 230 volts, 40 Amps, 10 KA rupturing capacity complete all as specified and as directed.
S&F MCB, SP, "C" series, 240 volts, 6 to 32 Amps, 10 KA rupturing capacity complete all as specified and as directed.
S&F starter switch of capacity 25 Amps working on 240 Volts, AC supply suitable for split type airconditioner complete all as specified and as directed. MAKE: CRAB TREE Cat part No. ACTO252504 or equivalent in ANCHOR/HAVELLS/L&T
M&L for Sub main wiring complete with two runs (1P+1N) of 6.0 Sqmm single core, PVC insulated unsheathed, FRLS cable, 1100 volts grade, multistranded copper conductor (with colour coding of Red/Blue/Yellow for phase and Black for neutral) and one run of 6.0 Sqmm single core, PVC insulated unsheathed, FRLS cable, 1100 volts grade, multistranded copper conductor as earth wire green in colour including lugs, drawn through and including 25mm dia PVC conduit and conduit accessories fixed on surface of wall/ceiling/roof/ floor complete all as specified and as directed. NOTE: Two runs of 6.0 Sqm copper conductor, One run of 6.0 Sqmm copper conductor as earth wire and one run of PVC conduit shall be measured as one unit length.
M&L for Sub main wiring complete with two runs (1P+1N) of 4.0 Sqmm single core, PVC insulated unsheathed, FRLS cable, 1100 volts grade, multistranded copper conductor (with colour coding of Red/Blue/Yellow for phase and Black for neutral) and one run of 4.0 Sqmm single core, PVC insulated unsheathed, FRLS cable, 1100 volts grade, multistranded copper conductor as earth wire green in colour including lugs, drawn through and including 25mm dia PVC conduit and conduit accessories fixed on surface of wall/ceiling/roof/ floor complete all as specified and as directed. NOTE: Two runs of 4.0 Sqm copper conductor, One run of 4.0 Sqmm copper conductor as earth wire and one run of PVC conduit shall be measured as one unit length.
S&F indoor lighting fixture recess mounting, 30 watts, 2x2 LED panel light fitting with ultra bright luminaire comprises of thermaly conductive material, pre wired with high efficiency electronic driver with high transluscent frosted diffuser gets glare free, smooth light distribution complete all as specified and as directed. MAKE: CROMPTON GREAVES Cat part No. LCPL-36-CDL or equivalent in PHILIPS / C&S
S&F decorative cute lines LED light fixture of 24 Watts capacity, 6000K, 220 Volts, 50 Hz AC supply with extruded aluminium heat sink, environmental friendly energy efficient light fitting, surface mounted including 24 Watts LED lamp and testing complete all as specified and as directed. MAKE: CROMPTON GREAVES Cat part No. LCCLB24-CDL or equivalent in HAVELLS/ PHILIPS / C&S
S&F Ceiling fan 5 star rated, 1200mm sweep of model No. ES-50(white colour) working on single phase 230 volts, 50Hz AC supply complete with down rod and canopy including electric connection from ceiling rose to fan connector with PVC insulated 3 core copper cable of size 0.75 sqmm complete all as specified and as directed. MAKE: HAVELLS (Model No. ES-50 5) / USHA / ORIENT
M&L for earthing complete with GI earth plate electrode of size 600mmx600mmx6mm thick buried directly in ground (earth pit not less than 2.25m deep below the normal ground level) with top edge of the earth plate not less than 1.5m below normal ground level connected to 32x6mm GI earth strip as earth lead connected by means of bolts, nuts, washers and check nuts made out of galvanised iron or steel all as shown on electrical plate No. 3 of SSR Part-I connected to common earth dolly including testing on completion complete all as specified and directed. NOTES: 1) The unit rate shall also include for earth work in any type of soil, PCC (1:3:6) type C1 chamber, pre-cast RCC (1:2:4) type B-1 using 20mm graded stone aggregate cover 50mm thick reinforced with TMT bars 8mm dia @ 100mm c/c both ways, funnel with watering pipe 20mm dia medium grade, GI protection pipe light grade 40mm dia and wire mesh complete in addition to item No. 1(a) to (e) of preamble (notes) under sub-heading earthing, specified on Sl. Page Nos. 422 & 423 of SSR Part-II. 2) Earthing lead and GI protection pipe beyond 7.5m will be measured and paid separately.
Supply and fix GI earth strip 32mm x 6mm earthing lead (beyond 7.5m from earth point) laid in ducts, floors, walls with suitable clamps all as specified and directed.
M&L for LT XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 1100 volts grade, cross sectional area 3.5 core, 400 Sqmm laid in trenches/floors/ducts or fixed on poles/walls with suitable clamps/saddles or drawn through pipes etc.,and connecting up with suitable size of lugs, glands and jointing material complete all as specified and as directed. Note: (i) Necessary excavation and earth work shall be measured and paid separately under relevant items of this schedule. (ii) Cable test results like continuity test, megger test shall be submitted to Engineer-in-Charge before the cable is laid.
M&L for HDPE DWC (Double wall corrugated) pipe of size 120mm (Outer diameter) x 103.5mm (Inner diameter) along with connected accessories like couplers, bends, end caps, etc., laid in trenches/floors/ducts or fixed on poles/walls for as in protection of LT/ HT cable complete all as specified and as directed.
S&F Changeover switch 630 Amps, 415V, AC 23A, 4 pole with sheet steel enclosure of suitable size including connecting up complete all as specified and as directed. MAKE: L&T Cat part No. CO46300OSOO or equivalent in ABB / SCHNEIDER
S&F MCCB 4 pole, 630 Amps, 50kA, 415 volts, 50 Hz adjustable over load 70-100% with thermal magnetic release Ics =100% Icu connecting up with necessary spreader links including sheet steel enclosure for mounting MCCB and fixing on wall with connected angle supports, brackets, nuts, bolts and washers complete all as specified and as directed. MAKE: L&T Cat part No. CM93008OOOOAG or equivalent in ABB / SCHNEIDER
MS KAMARIKAR CONSTRUCTION
RELIANCE SALES AGENCY
Sree Tirumala Enterprises
M/s Bismi Builders & Enterprises
kakolil trade agencies
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .