Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹41.7 LAccepted-Finance | L1 | Accepted-Finance OK | |
| 2 | L2₹43.0 L+₹1.3 L (3.20%)Accepted-Finance | L2 | Accepted-Finance OK | |
| 3 | L3₹43.2 L+₹1.6 L (3.80%)Accepted-Finance | L3 | Accepted-Finance OK | |
| 4 | L4₹45.1 L+₹3.4 L (8.26%)Accepted-Finance FLAT NO 101 2ND FLOOR RAGHAVENDRA RESIDENCY PLOT NO 1 2 3 SURVEY NO 27 PICKET SECUNDERABAD 500026 | HYDERABAD | TELANGANA | 500026 | L4 | Accepted-Finance OK | |
| 5 | L5₹45.3 L+₹3.7 L (8.78%)Accepted-Finance HOUSE NO 2 4 136 LINGREDDY MANSION BLOCK NO IV OPP HANUMAN TEMPLE TADBUND SECUNDERABAD 500009 | SECUNDERABAD | HYDERABAD | TELANGANA | 500009 | L5 | Accepted-Finance OK |
Tender Value
₹49.7 L
EMD Value
₹99,400
Closing Date
26 Jul 2023, 6:00 pmClosed
GE (UTILITY) SECUNDERABAD
GE UTILITY SECUNDERABAD MUDFORT SECUNDERABAD-500003
REPAIR / RENEWAL OF STREET LIGHTS AND ALLIED WORKS UNDER AGE E/M NO II OF GE(U) SECUNDERABAD
2023_MES_607122_1
GE (U)/SEC/TOKEN/29 OF 2023-2024
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
SECUNDERABAD
AS PER NIT
8 documents required · 8 mandatory
₹500
GE (UTILITY) SECUNDERABAD
₹99,400
Yes
11 Aug 2023
30 Jun 2023
2 Aug 2023
30 Jun 2023
26 Jul 2023
14 Jul 2023
Amount
Supply and fixing post top lantern LED type 25/30/35 watt 230 Volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp complete. complete all as specified and directed by Engineer -in-charge.
Supply fixing connecting and testing decorative LED Bollard light with opal diffuser & aluminium reflector of 8/9/11watt 3 Feet LED including nut, bolts, washers, clamps etc complete all as specified and directed by Engineer -in-charge
S&F LED street light fitting 90 Watt 230 V AC outdoor type with high pressure die cast aluminum housing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete, lighting source and lens embedded PC cover having TOP OPENING separate driver compartment with IP66 protection and impact resistance of IK07 with 10 KV Built-in-Surge Protection Device, road way light fitting with high power LED as light source of capacity 90 watts with suitable drivers etc and connecting with 1.5 Sqmm copper conductor PVC insulated three core weather proof cable etc, fixing to wall/pole, incl taking down old unsv one complete all as specified and directed. Note : (i) Contractor has to produce LM-79/LM-80 certificate alongwith purchase vouchers. (ii) Surge protection of the drive should be 10 KV
All as per item No-03 here in before but 100 watts.
All as per item No-03 here in before but 120 watts.
S&F LED flood light 100 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp die-cast aluminium , flood light suitable for highlighting architectural facade and general purpose lighting, with high power LED as light source of capacity 120 watts with suitable drivers etc and connecting with 2.5 Sqmm aluminium conductor PVC insulated twin core weather proof cable etc, fixing to wall/pole complete incl taking down old unsv one all as specified and directed. Note : (i) Contractor has to produce LM-79/LM-80 certificate alonwith purchase vouchers and Guarantee certificate from Manufacturer. (ii) Surge protection of the driver should be 10 KV
All as per item No-06 here in before but 120 watts.
All as per item No-06 here in before but 150 watts.
All as per item No-06 here in before but 200 watts.
Supply only LED Driver of similar wattage with operating voltage input ac 85- 300 volt , pf> .95 as per IS 15885 with inbuilt surge protection of minimum 5 kv and BIS certified suitable for 60 watts LED street light fittings of any make complete all as specified and directed.
Supply only LED Driver of similar wattage with operating voltage input ac 85- 300 volt , pf> .95 as per IS 15885 with inbuilt surge protection of minimum 5 kv and BIS certified suitable for 70/72 watts LED street light fittings of any make complete all as specified and directed.
Supply only LED Driver of similar wattage with operating voltage input ac 85- 300 volt , pf> .95 as per IS 15885 with inbuilt surge protection of minimum 5 kv and BIS certified suitable for 90 watts LED street light fittings of any make complete all as specified and directed.
Supply only LED Driver of similar wattage with operating voltage input ac 85- 300 volt , pf> .95 as per IS 15885 with inbuilt surge protection of minimum 5 kv and BIS certified suitable for 100/110/120 watts LEDstreet light fittings of any make complete all as specified and directed.
Supply only LED Driver of similar wattage with operating voltage input ac 85- 300 volt , pf> .95 as per IS 15885 with inbuilt surge protection of minimum 5 kv and BIS certified suitable for 100 watts LED flood light fittings of any make complete all as specified and directed.
Supply only LED Driver of similar wattage with operating voltage input ac 85- 300 volt , pf> .95 as per IS 15885 with inbuilt surge protection of minimum 5 kv and BIS certified suitable for 120 watts LED flood light fittings of any make complete all as specified and directed.
Supply only LED Driver of similar wattage with operating voltage input ac 85- 300 volt , pf> .95 as per IS 15885 with inbuilt surge protection of minimum 5 kv and BIS certified suitable for 150 watts LED flood light fittings of any make complete all as specified and directed.
Supply only LED Driver of similar wattage with operating voltage input ac 85- 300 volt , pf> .95 as per IS 15885 with inbuilt surge protection of minimum 5 kv and BIS certified suitable for 200 watts LED flood light fittings of any make complete all as specified and directed.
S&F in repairs surge protection of 10 KV suitable upto 100W LED light fittings suitable to operate on input voltage 440 AC, 50 Hz, complete all as specified and directed.
Supply andd fix locally available gate / garden light best quality metal Silver / metal black Decorative Exterior of size not less than 300 mm X220 mm with and including LED bulb 9 watt suitable for outdoor installation and suitable for fixing in 40/50 mm dia GI pipe including necessary connections complete all as specified and directed including taking down old one .
Supply and fix locally available gate / garden light best quality Black Color Steel Shade With Fiber Glass Outdoor Gate Lamp of size not less than 360 mm X250 mm with and including LED bulb 9 watt suitable for outdoor installation and suitable for fixing in 40/50 mm dia GI pipe including necessary connections complete all as specified and directed including taking down old one .
S&F LED High Bay light 90 W luminaries with high luminous efficacy,IP 65 protected, front toughened glass with discrete high lumen LED along with Reflector including dismantling of old unserviceable fitting all accessories complete all as directed.
Material and Labour for drawing two runs of PVC insulated unsheathed single core multi stranded copper conductor FRLS cable of size 1.50 sq mm with one run of PVC insulated unsheathed single core multi stranded copper conductor FRLS cable of size 1.50 sq mm including 20mm dia PVC conduit medium grade exclusive of boxes but inclusive of all tees, bends, elbow, reducers etc and fixing accessories such as couples, lock nuts, saddles, pipe hooks, clamps etc complete all as specified.
Supply and lay PVC Insulated , PVC sheathed industrial round multicore flexible cable with copper conductor 3 core 2.5 sqmm including PVC conduit 20 mm dia medium grade and necessary bends, fittings and fixtures as required for connection of light fittings . Note : Used for garden light connection, excavation, retuning filling etc will be measured and paid separately.
Supply and lay PVC Insulated , PVC sheathed industrial round multicore flexible cable with copper conductor THREE core 1.5 sqmm as required for connection of light fittings .
Supply and fixing street light mounting bracket, made out of Medium grade GI Tubing 40 mm bore , bend into shape inner angle not less tan 120° and over all length not less than 1.2 Mtr including suitable size clamps made from not less than 25x3 mm ms strip , Nut, bolts 06 mm dia with washers complete fixing arrangement etc and duly painted two coats of synthetic enamelled Aluminium pait over a coat of red oxide befor fixing all as directed.
S & F hot press moulded SMC junction / terminal box of size with internal diamensions of 200 x 140 x 95 mm with hinged door, incl provision of 2 way connector 415 Volts made out of polycarbonate or bakelite and 1 No MCB of 6 Amps with DIN bar, drilling holes for cable connections, connecting incoming and or out going cables by providing suitable of size of cable lugs/glands, fixied on pole by means of clamps made out of MS flat iron of size 25 mm x 3 mm including dismantling of old unserviceable all as specified and as directed.
Excavation in trenches not exc 1.5 mtr wide and not exc 1.5 mtr in depth; for trench of cable etc and getting out in hard soil complete all as specified and as directed.
Excavating in Trenches, not exc. 1.50 mtr wide and exc. 1.50 mtr but not exc. 3.00 mtr in depth, for Foundation of Poles, etc. and getting out in Soft/ Loose Soil, complete all as specified and as directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc 25 cm in Soft/loose soil complete all as specified and as directed
Removing excavated material to a distance n.exc 50 mtr and depositing where directed at level n.exc 1.5 mtr above the starting point all as specified and as directed
M&L filling EARTH cushioning of laying of cables to the full width of excavated trench 8 cm thick before laying the cable and 15 cm above the cable, gently punned down, stretching and testing of cable on transformer yard etc complete all as specified and directed. Note :- Thickness of sand cushion after punning down (i.e 18 cm) shall be measured for payment.
M & L for brick protection cover of old size bricks common burnt clay building bricks sub class ’B’ laid dry and flat abutting each other with width equal to length of brick and gap between adjacent bricks not exceeding 10 mm complete all as specified.
Supply and lay in trenches/fixed to walls/poles etc and commissioning XLPE insulated and PVC sheathed heavy duty LT 1100 Volts grade armoured under ground cable with aluminium conductor of 2 Core 10 Sqmm incl taking out of existing cable all as directed. Note :- Earth work excavation, sand cushioning and brick protection shall be measured and paid separately.
All as per item no:33 above but 4 Core 10 Sqmm
All as per item no:33 above but 4 Core 16 Sqmm
Trimming/pruning and removing of tree branches or any other foreign objects from HT/LT over head conductor and clearing the OH Line of any type and size for one span of any length in 2 way /4 way/6 way conductor system. Notes: The contractor is responsible for provision of Necessary T & P and safety equipments to complete the job.
M & L for painting the existing LT steel poles of 9.0 Mtr long including cross arms, clamps, street light junction boxes etc with 2 coats of aluminium paint over a coat of red oxide primer including throughly cleaning the existing surface, painting the poles up to 1.5 Mtr height with alternate bands 30 cm height (3 Nos black and 2 Nos Yellow) from ground level, complete all as specified and directed.
M & L for Painting the existing LT PCC poles with applying two coat of cement based paint over one coat of primer including painting of cross arms, clamps, etc with two coats of aluminum paint and providing alternative band of 30 cm width (3 Nos black and 2 Nos yellow) from bottom of pole to 1.5 meter height complete all as specified and directed.
Labour only for releasing the binding of ACSR conductor of LT / HT over head line from insulator, removing the jumper, connector, service wire, UG cable and restringing the existing ACSR conductor of any size, length, span upto desired sag and fixing the existing ACSR conductor on insulators by proper binding, jumper connection etc complete all as specified and directed. Notes:- (i) Single run of conductor will be measured as one unit which is deemed to be included in the quoted unit rate. (ii) Extra aluminum conductor required for jumpers and binding purpose is deemed to be included in the quoted unit rate.
M&L cross arm bracing supports, clamp and back plate from structural steel section including nuts & bolts washer, welding, bending, cold or hot drilling holes for bolts in any shape or size as indicated or as directed and including of one coat primer, one under coat and one finishing coat of aluminium paint for making clamp to be used for fixing of flood light /street light on pole including taking down old unserviceable.
Supply & Erecting Steel Tubular Swaged Pole Type 410-SP-31 (9.0 METRE long) including Cast Iron Base Plate, Finial Taper Plug, Cap, Mild Steel Bolts, Nuts, Screws including applying Two Coats of Black Bituminous Paint Internally and Externally upto Planting Depth and applying with Two Coats of Aluminium Painting over a Coat of Aluminium Primer (Externally from Top of Coping) including dismantling old unserviceable complete all as specified and as directed.
Supply and fixing lantern of suitable size for fixing of flood light, cap type to be fixed on the top of 9 m SP-31 Steel pole , made of MS pipe medium grade dia greater than the top dia of the pole of length 0.30 M supported by MS flat iron of size 50X6 mm 4 nos including two coat of aluminium painting over a coat of redoxide primer including taking down old unserviceable complete all as directed
Supply and replace GI pipe fixed on the top of gate piller by 50 mm dia medium grade GI pipe of length 30 cm( 20 CM inside the piller and 10cm above the piller including necessary cement work and making hole on GI pipe if required complete all as directed. Note: Quoted rate inclusive of making good of disturbed suface including necessary concreting work, plastering and painting to match with the adjoining surface.
Material and labour in replacement of old unserviceable for galvanized iron tubing 40 mm bore light grade with all fitting for protection of cable /for fixing of garden light including necessary GI clamps, bolts, nuts, washers and locking arrangements etc., complete and making hole on wall complete all as specified and as directed.
Material and labour in replacement of old unserviceable for galvanized iron tubing 50 mm bore light grade with all fitting for protection of cable /for fixing of garden light incl necessary clamp, bolt/nut if any and making hole on wall complete all as specified and as directed.
M&L for twin core 1100 volt grade aluminium service wire cross sectional area 4.0 Sqmm for connection of light complete all as specified and directed
M&L for twin core 1100 volt grade aluminium service wire cross sectional area 6.0 Sqmm for connection of light complete all as specified and directed
Cutting the existing road straight by manual, depth and width not less than 1 mtr below ground level for passing of underground cable and filling back with excavated soil upto 75% road portion and 25% shall be made with cement concrete 1:2:4 (using 20 mm graded aggregate stone complete all as specified and directed.
Dismantling LT steel tubular pole of any height by taking out from PCC foundation complete and shifting to other location as directed including fixing the pole in true vertical position including excavation and earth work, PCC 1:4:8 type D2 (using 40mm graded stone aggregate) as base concrete and PCC 1:3:6 type C2 (using 20mm graded stone aggregate) in both foundation and coping of poles all as specified in SSR Part I-2009 and applying two coats of aluminium paint to pole surface complete all as directed by Engineer-in-Charge.
M&L for Making hole 2 nos ( one hole near JB another hole near bottom portion of bracket) on existing steel tubuler pole ( SP -31 ) of suitable size for passing of Street light connection HV Round cable 3 core 1.5 Sqmm from Junction Box to street light complete all as directed
Pertially Demolition of coping of pole as required for placing of cable protection pipe and making good the same by using PCC and rendering complete al as speccified and directed. Note: Quoted rates deemed to be inclusive of PCC and rendering.
Cutting of bushes and making the area clean at places near street lights all as specified and as directed.
S & F single phaseTimer switch programmable with current carrying capacity of 16A for street light controlling after removing the old unserviceable timer from the panel all as specified and as directed.
Supply and connecting ML2 Contractor 32A,415 volt capacity after removing the old unserviceable ML2 connector from the panel all as specified and as directed.
Advance Maintenance Free G.I. SAFE EARTHING Electrode with PIPE of not less than 50 mm outer dia( THICKNESS NOT LESS THAN -2.5MM) and two meter length, The electrode should be of galvinised (80 -100 micron) along with earth lead as Galvanised steel strip of size 32 X6 mm 7.5 m . The GI Electrode shall be pre-filled with Cristaline Conductive Material (CCM) . The GI electrode shall be surrounded with 25 kg BackFill compound to provide maximum contact between the electrode and Back Fill Compound. .The earting pit should be cover with pcc(1:2:4 , B1) cover ,of 450 x 450 mm complete all as specified and directed.
Supplying & fixing MCB single pole (`C’ series ) 5 to 30 Amps capacity suitable for 240 volts having current rating 10 KA including Taking down old MCB SP any type & any capacity complete all as specified and directed. Make : Cat No 408695 Make Legrand or equvailent as approved by GE.
S&F MCB SPN 40 amp rating 240 Volt including Taking down old MCB SPN/DP any type & any capacity complete all as specified and directed.Cat No 408636 Make Legrand or equvailent as approved by GE.
S&F in repair mild steel hinges suitable for LT panel board shutters incl welding, riveting and painting complete all as specified and as directed.
Disconnecting and taking down existing bus bars 4 wire system from LT panel board cleaning with CTC applying with becktol solution, removing old insulation and providing new heat shrink insulating sleeves, connecting and fixing in the same panel with new nuts, bolts, washers of suitable size complete all as specified and directed.
Disconnecting and taking out old existing worn out control wiring connections incl cable lugs of LT panel board of 4 wire system and supply and connect with new cable PVC insulated, stranded copper conductor 2.5 sqmm incl new copper lugs and nuts, bolts, washers complete all as specified and directed.
Disconnecting and taking out old existing worn out cable lugs, nuts, bolts, washers etc from LT panel board of 4 wire system (incomming and outgoing) and supply and connect with new aluminium lugs and nuts, bolts, washers etc complete all as specified and directed.
Taking out old existing worn out neoprene gasket from shutters of LT panel board single door /double doors or openable on both sides and supply and fix new neoprene gasket complete all as specified and directed.
.Supply and fixing cable route indicator made out of PCC 1:2:4 of size 20cmx20cmx90cm dully painted with red colour by two coat of enamel paint and writing MES LT cable with white paint on all sides complete all as directed.
S &F Copper conductor cable 10 sqmm x 4 core, 650 V/1100 V, un-armoured all as specified and as directed.
M&L in replacement of control panel for High Mast Light comprising of Timer, contactor, starter, up & down push button in sheet steel enclosure of 3.0mm thick CRCA sheet and fixed on PCC plateform all as specified and as dirceted. Make : National/Universal/SMS Panels/EAP Panels
sree venkateswara enterprises
SUN LIGHT HOUSE
L and S ENTERPRISES
omsai thermax engineers
Sri venkateswara Electricals
Srinivasa Consructions
LEOENTERPRISES
Universal refrigeration and Engineering Company
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .