| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.0 LAccepted-AOC | L1 | Accepted-AOC Lowest | |
| 2 | L2₹17.0 L+₹1,050.54 (0.06%)Rejected-Finance | L2 | Rejected-Finance High | |
| 3 | L3₹17.1 L+₹14,846 (0.87%)Rejected-Finance | L3 | Rejected-Finance High | |
| 4 | L4₹17.4 L+₹39,991 (2.35%)Rejected-Finance | L4 | Rejected-Finance High | |
| 5 | L5₹17.5 L+₹50,392 (2.97%)Rejected-Finance | L5 | Rejected-Finance High |
Tender Value
Refer Docs
EMD Value
₹40,000
Closing Date
3 Feb 2021, 6:00 pmClosed
GE Gurdaspur
Garrison Engineer, Gurdaspur (Tibri)
Certain sanctioned works for provn of temp shed, tilling and waiting shed at Tibri Mil Stn under GE Gurdaspur.
2021_MES_409977_1
GE GSR-69/2020-21
Open Tender
Civil Works
Item Rate
180 days
Garrison Engineer, Gurdaspur (Tibri)
As per tender documents
7 documents required · 7 mandatory
₹500
GE Gurdaspur
₹40,000
17 Feb 2021
6 Jan 2021
5 Feb 2021
6 Jan 2021
3 Feb 2021
21 Jan 2021
Amount
M&L for excavating in post holes (or similar holes) in soft/loose soil each n. exc 0.5 cum getting out, returning, filling in and ramming earth of broken rubble mixed with earth around, in layers not exc 25cm, watering and removjng surplus soil to a distance n. exc 50m and making good surface complete all as specified and directed.
M&L for cement concrete 1:2:4, type B2 (40mm graded aggregates) as in columns, pillars, boundry pillars and posts (includig, caps and bases) complete all as specified and directed.
S&F mild steet Gde Fe-410-W as in roof trusses (framed), trussed purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc complete all as specified and directed.
S&F pre-painted galvatume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and directed.
M&L for preparation of untreated steel/ iron surfaces of any description, over 10cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint over and incl one coat of red oxide primer complete all as specified and directed.
S&F for 0.71 plain aluminium sheeting alloy 31000 H4 in ridges, hips valiey, gutter drip and straight flashing (length and girth as fixed) complete all as specified and directed.
Surface excavation n. exc 30 cm deep and averaging 15cm deep and getting out in soft/loose soil.
M&L for hardcore of broken bricks gauge n. exc 63mm not exc 100mm, deposited, spread and levelled in layers n. exc 15cm thick, watered and rolled/framed to a true surface complete all as specified and directed.
M&L for 75mm thick cement concrete type D-2, 1:4:8 (using 40mm graded aggregate) as in sub base complete all as specified and directed.
M&L sand filling under floors or in foundations including watering and consolidation complete all as specified and directed.
M&L for machine pressed precast concrete interlocking paver block any shape and size confirming to IS- 15658-2006 of 80mm thickness, M-40 grade with grey cement and pigments complete all as specified and directed.
M&L for PCC 1:2:4 type B-1 (using 20mm graded stone aggregates) as in roof kerbs or mud stops, rounded or chamfered on edges and like including weathering slight rounded and throating complete all as specified and directed.
M&L for brick work with sub class 'B' bricks, straight or curved on plan to exc 6m mean radius, built in cement morter 1:4 complete all as specified and directed.
M&L for rendering 15mm thick on fair faces of brick work or concrete surfaces in CM 1:4 and finishing even and smooth without using extra cement complete all as specified and directed.
M&L for prepration of newly plastered/ unplastered of walls and applying two coats of cement base paint of shade as approved over a coat of cement primer complete all as specified and directed.
Excavation in trenches in soft /loose soil not exc 10 Sqm on plan and not exceeding 1.5 mtr depth foundation, shafts, well, manhole, pier holes etc getting out and forming bottom surfaces by ramming to required gradient complete all as specified and directed.
Returning, filling in, excavated earth including spreading , leveling, watering and well ramming in layers each n.exc 25 cm thick in soft loose soil complete all as specified and directed.
Removing surplus spoil to a distance exceeding 50 meter and not exc 250meter depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and directed.
M&L for cement concrete type B2, 1:4:8 (40mm graded stone aggregates) as in foundation complete all as specified and directed.
S&F non skid ceramic coloured tiles 7 to 8mm thick (square/ rectangular) area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm in floors etc set and jointed in neat cement slurry and pointed in white or colour cement to match the colour of tiles over and including 15mm thick screed bed in CM 1:6 complete all as specified and directed.
All as per Srl item No 21 above but on vertical surfaces but on rendering 10mm thick in CM 1:4.
S&F non skid ceramic coloured tiles 7 to 8mm thick (square/ rectangular) area of each tile exceeding 0.06 Sqm but not exceeding 0.11 Sqm in floors etc set and jointed in neat cement slurry and pointed in white or colour cement to match the colour of tiles over and including 15mm thick screed bed in CM 1:6 complete all as specified and directed.
M&L roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust etc and brushing neat ceemnt slurry with 3.0 kg of cement per sqm complete all as per specified and directed.
Taking down cement plaster of any description on brick walls etc including raking out joints, hacking for key scrubbing down with water etc complete all as specified and directed.
Taking down chowkats or frames from the opening of size exceeding 1.5 sqm but not exc 4 Sqm each with shutters (without taking off shutters from the frames) complete all as specified and directed.
Taking down shutters of any description of size exceeding 1 sqm and not exceeding 2 sqm each complete and refixing in the same opening after easing and adjustment to the required size complete all as specified and directed.
S&F pressed steel frames 1.25 mm thick for door size of frame 105 x 60mm with one or more rebates including necessary fixing lugs, hings, lock strike plate and filling of chowkats with PCC 1:3:6 type C-1 (using 20mm graded stone aggregates) and forfilling of hold fast and tarring to inner surface (surface in contract with concrete/ brick surface) of chowkats and hinges and two coats of synthetic enamel paint to outer surface with red oxide primer after preparation of surfaces complete all as specified and directed.
S&F 35mm thick flush shutters , solid core construction , with block board core and plywood face panels, commercial type on both sides Complete all as specified and directed.
S&F 300mm long aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed complete all as specified and directed.
S&F 300 mm aluminium, anodised, barrel tower bolts of extruded section and fixed complete all as specified and directed.
S&F 150mm extruded aluminium alloy handles, fabricated type, anodised complete all as specified and directed.
S&F floor door stopper of aluminium alloy body and tongue anodised with hard drawn steel spring fixed to door shutter of size 140mm complete all as specified and directed.
M&L for two coats of synthetic enamel painting on wooden surfaces of any description over 10cm in width or girth not otherwise described above pink primer including preparation of surfaces complete all as specified and directed.
M&L for 100mm thick cement concrete type B-1, 1:2:4 (using 40mm graded stone aggregate) laid in alternative bays complete all as specified and directed.
M&L for providing and fixing asbestous cement sheets 6mm thick, 100mm wide as in dividing strips in PCC flooring complete all as specified and directed.
M&L for PCC 1:4:8 type E-2 using 40mm graded stone aggregate in fundation, mass concrete complete all as specified and directed.
E/M Point wiring with 1.5 sqmm PVC instulated unsheathed single core stranded copper conductor FR 1100 volts cable along with 1.5 sqmm PVC insulated standard earth conductor cable drawn through and including 20mm dia rigid PVC conduit and accessories fixed on wall/ surface and steel terminal box 14 SWG pressessed concealed in wall complete with 3mm thick laminated sheet cover all as per ISI for 3 Pin, 5 Amps socket outlet complete all as directed.
S&F swith piano flush type single pole 1 way 5 Amp complete all as specified and directed.
S&F socket outlet 2 in one 3 pin 5 amps flush type complete all as specified and directed.
S&F in repair sheet metal enclosure for DB’s when MCB’s to be used of 240 volt 4 way with 200 amps rated bus bar SPN double door complete all as specified and directed.
S& F in repair MCB single pole 6 amps to 32 amps , C series complete all as specified and directed. Make-Havells/Standard/ Indoasian.
All as per Srl item No 42 above but single pole and neutral 6 amps to 32 amps, C series.
S&F on 2 PVC square blocks surface mounting universal batten housing made of powder coated CRCA sheet suitable for upto 1 x 18/20 W LED tube rod single sided in taking down old unserviceable fitting complete all as specified and directed.
S&F LED tube light 20W (single sided connection) ultra bright LED polycarbonate tube light with very high efficacy suitable for fitting into existing/ new tube light batten fitting complete all as specified and directed.
S&F new generation energy saving 60 watt LED street light luminiaries withlong life versatile pressure die-cast aluminium, housing with high power LED as lighting source and lens embeded PC cover road way luminaire complete all accessories, connecting up with three core flexible copper conductor cable complete all as specified and directed.
M&L for sub main wiring with two run of 4 sqmm single core multi stranded PVC insulated and unsheathed copper conductor (red for phase and black for neutral) of grade 1100 volt FR cable in and including electrical grade PVC conduits of desired colour not less than 1.2 mm thick and 25 mm wide and 4 sqmm copper conductor cable PVC unsheathed green coloured for earthing with complete accessories duly connected with earth dolly complete all as specified and as directed incl taking down old unserviceable one.
Supply installation commessioning of metal top freezer single phase 240 volt 50Hz 400 ltrs capacity min 3 star complete all as specified and directed.
Voltage stabilizer for automatic aperation single phase naturally air cooled indoor type and designed for input variation between 170 volt to 250 volt with output voltage stabilizer at 230 volt accurancy of +2.5% and capacity 3 KVA complete all as specified and directed.
RATTAN CHAND CHANDAN AND CO
buta singh and sons
P S BUILDERS
M/S GAGAN CONSTRUCTION CO
RAM CHAND SAINI & BROS.
S S CONSTRUCTION
D.RAJ And CO.
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .