Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.0 LAccepted-AOC 63 2ND MAIN ROAD NGO COLONY ADAMBAKKAM CHENNAI 600 088 | CHENNAI | CHENNAI | TAMIL NADU | 600088 | L1 | Accepted-AOC Being L1 and reasonable | |
| 2 | L2₹7.9 L+₹1.7 L (26.8%)Rejected-Finance NEIKUPPI VILLAGE VENGAPAKKAM POST KALPAKKAM 603 102 KANCHEEPURAM DIST | KALPAKKAM | KANCHEEPURAM | TAMIL NADU | 603102 | L2 | Rejected-Finance Being L2 |
Tender Value
₹8.8 L
EMD Value
₹17,600
Closing Date
21 Nov 2023, 6:00 pmClosed
AGE(I) Navy Chennai
AGE(I) Navy Chennai Military Engineer Services Fort St George Rajaji Salai Chennai 600 009
REPAIR TO INTERNAL ELECTRIFICATION AT KALPAKKAM AND REPAIRS TO EXTERNAL WATER SUPPLY AT VELLACHY UNDER AGE(I) NAVY CHENNAI
2023_MES_624022_1
AGE(I)/NAVY/CHN/8453 of 2023- 24
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Chennai
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
AGE(I) Navy Chennai
₹17,600
Yes
14 Feb 2024
19 Oct 2023
22 Nov 2023
19 Oct 2023
21 Nov 2023
2 Nov 2023
20 Oct 2023 - 26 Oct 2023
Amount
Taking down old unserviceable copper/aluminium point wiring (light, fan, socket or power) including old unserviceable fixture and fittings complete etc removing the materials for taking credit and making good the disturbed surface of wall/floor etc.
Taking down carefully old unserviceable sub main wiring with aluminum conductor cable 4/6/10/16 Sqmm in PVC conduit complete removing the materials and taken as credit and making good the disturbed surface of wall / floor etc.
M&L for point wiring for One light point or fan/Exhaust fan point controlled by one regulator / one switch with 1.5 sqmm (Nominal area) unsheathed multi-stranded copper conductor PVC insulated cable 1100 volts grade single core FRLS drawn into and including non-metallic rigid PVC conduit / PVC Casing Caping suitable size, FRLS wiring, along with 1.5 sqmm unsheathed multi stranded copper conductor cable PVC insulated 1100 volts grade as earth continuity conductor connected to common earth dolly fixed to wall/ ceiling roof excluding Modular Metal flush box / PVC Modular Box and white cover plate with frame the switches, sockets, fan regulator etc as required suitable for Modular type fitting /fixture etc which shall be measured and paid separately all as specified and directed.
All as per Sl Item No. 03 above but for One 3 pin socket outlet 5 amps socket on independent board with cables 1.5 sq. mm size
All as per Sl Item No. 03 above but for One 3 pin socket outlet 5 amps socket on Same Board with other switches, with cables 1.5 sq. mm size
All as per Sl Item No. 03 above but for One light point controlled by two 2-way switches, with cables 1.5 sq. mm size
All as per Sl Item No. 03 above but for One bell/ buzzer point controlled by one push button on the same board with other switches or independent with cables1.5 sq.mm. size
All as per Sl Item No. 03 above but for 4 sqmm cable for one 3 pin socket outlet 15 Amps on independent board with 4 sqmm cable as earthing conductor.
S&F modular socket modular 2/3 pin 6 A flush type 2 module.
S&F modular socket modular 2/3 pin 16 A flush type 2 module.
S&F Modular switch flush type single pole one way 10 A, 240 Volts complete all as specified and as directed including taking down old unserviceable switches.
S&F in repair switch Modular type single pole two way 10 A, 1 Module, 240 Volts including taking down old unserviceable switch and removing the material for taking credit complete all as specified and as directed.
S&F in repair switch Modular type single pole one way 16 A, 1 Module, 240 Volts including taking down old unserviceable switches and removing the material for taking credit complete all as specified and as directed
S&F ceiling rose 3 ways PVC / Polycarbonate, isolated body complete all as specified and as directed.
S&F call bell Ding dong .
S&F in repair Stepped type Modular electronic fan regulator 120W, 2 Module flush type on the existing phenolic laminated sheet etc complete including taking down old unserviceable electronic fan regulator and removing the material for taking credit all as specified and directed.
S&F in repair Modular Bell push flush type 6 A, 1 Module, 240 Volts including taking down old unserviceable bell push and removing the material for taking credit complete all as specified and as directed.
S&F Repairs LED light fitting 4feet,1x20w,a trendy wall mounted battern,with extruded aluminium housing, with integrated LED driver, etc. complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size. Make Crompton Or Wipro, Havells, Philips. Including taking down old unserviceable electronic fan regulator and removing the material for taking credit all as specified and directed.
S&F Repairs Energy saving new generation 10W LED IP65 bulkhead luminaries with opal diffuser Including taking down old unserviceable electronic fan regulator and removing the material for taking credit all as specified and directed.
S&F Repairs LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete including taking down old unserviceable electronic fan regulator and removing the material for taking credit all as specified and directed.
S&F repairs LED luminaries 600 mm x 600 mm,35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete. including taking down old unserviceable electronic fan regulator and removing the material for taking credit all as specified and directed.
S&F Repairs round shape 6 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete including taking down old unserviceable electronic fan regulator and removing the material for taking credit all as specified and directed.
S&F modular white cover plate with frame 2 module
S&F modular white cover plate with frame 3 module
S&F modular white cover plate with frame 4 module
S&F modular white cover plate with frame 6 module
S&F modular white cover plate with frame 8 module
S&F of Modular Metal thread inserts Plastic box 1/2 Module
S&F of Modular Metal thread inserts Plastic box 3 Module
S&F of Modular Metal thread inserts Plastic box 4 Module
S&F of Modular Metal thread inserts Plastic box 6/8 Module
S&F Angle Lamp holder PVC / Polycarbonate type with back plate suitable for batten fitting complete all as specified and directed.
Supply Only LED 9/12/18 watt bulb.
S&F for sub main wiring/power wiring with 2 runs of 4 sqmm PVC insulated stranded copper conductor FRLS cable and one run of 4sqmm copper FRLS cable as earth lead in PVC conduit all as specified.
M&L for sub main wiring with 2 runs of 10 sqmm PVC insulated stranded copper conductor FRLS cable and one run of 10 sqmm copper FRLS cable as earth lead in suitable PVC conduit/Casing Caping all as specified.
M&L for sub main wiring with 2 runs of 2.5 sqmm PVC insulated stranded copper conductor FRLS cable and one run of 2.5 sqmm copper FRLS cable as earth lead in suitable PVC conduit all as specified.
S&F 2.5 Sqmm PVC round sheathed (flexible)industrial cable 1100 volts grade Cable with copper conductor
S&F Sheet metal enclosures with socket plug top and MCB SP 20A, 240 volts, with a two pin and earth plug socket complete with one single MCB 20 Amps, 240 volts (for AC ) including taking down old unserviceable old unserviceable Sheet metal enclosures with socket plug top complete all as specified and directed.
S&F amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of SP 6 To 32 AMP in the MCB DB complete with connection testing and commissioning
All as per Sl item No. 39 above but of SPN 40 to 63 AMP
S&F RCBO DP,100mA, 240 volts 63 Amps with Front face indication for earth leakage fault IP 20 protected terminals 35 sq mm terminals Sliding shutters. Complete all as specified and as directed by Engr-in-charge. Make:- Legrand Cat Part No 4113 35. or equivalent in make as specified in PS
S&F Isolator SP 63 Amp, 240 Volts complete all as specified and as directed.
S&F Isolator TP 63 Amp, 240 Volts complete all as specified and as directed.
S&F Isolator TPN 63 Amp, 415 Volts complete all as specified and as directed.
Supply only condenser 2.5 MFD (for Ceiling Fan) complete all as specified and directed.
Taking down after disconnection of electrical connections etc of the existing wall mounting fan of any size of any make and checking for fault and hanging back after carry out all repair works including connecting up complete all as specified and directed by Engineer in Charge
Rewinding of wall mounting fan of any type and make, stator coil with super enameled copper winding wire of appropriate gauge / quantity of burnt stator coil.
S&F only ball bearing
S&F only capacitor of 4 mfd for wall mounting fan
S&F only condenser holder
Scrubbing / removing the existing paints from the wall mounting fan 400 mm sweep and painting the fan with two coats of synthetic enameled paint over a coat of metal oxide primer.
Taking down after disconnection of electrical connections etc of the existing Exhaust fan 300mm / 450mm sweep of any make and checking for fault and fixing back in position after carrying out all repair works including connecting up complete all as specified and directed by Engineer in Charge
Rewinding of exhaust fan 300mm sweep stator coil with super enameled copper winding wire of appropriate gauge / quantity of burnt stator coil complete all as specified and directed by Engineer in Charge
Rewinding of exhaust fan 450mm sweep stator coil with super enameled copper winding wire of appropriate gauge / quantity of burnt stator coil.
S&F ball bearing
S&F capacitor of 4 mfd for Exhaust fan.
Scrubbing / removing the existing paints from the exhaust fan 300/ 450mm sweep and painting the fan with two coats of synthetic enameled paint over a coat of metal oxide primer.
S&F only new fan blades set for 300 mm sweep fan
S&F only new fan Blades for exhaust fan of 380 to 450mm sweep
Taking down after disconnection of electrical connections etc of the existing ceiling fan 1200mm sweep of any make and checking for fault and hanging back after carry out all repair works including connecting up complete all as specified and directed by Engineer in Charge
Rewinding of ceiling fan 1200mm sweep stator coil with super enameled copper winding wire of appropriate gauge / quantity of burnt stator coil.
S&F ball bearing of ceiling fan 1200mm sweep.
S&F capacitor of 2.5 mfd for ceiling fan 1200mm sweep.
S&F condenser holder
S&F new rubber shackle with bolt nut split pin complete
Scrubbing / removing the existing paints from the ceiling fan 1200 mm sweep and painting the fan with two coats of synthetic enameled paint over a coat of metal oxide primer complete all as specified and directed by Engineer in Charge.
Removing the damaged and corroded exhaust fan louvers and replace with new louvers of size up to 300mm sweep complete all as specified and directed.
Taking down defective storage water heater of any capacity from buildings after disconnecting carefully water and electric connection, opening the bottom cover replacing the defective parts fixing the cover and refixing in original position reconnecting both water and electric connection and testing complete all as specified and directed. Notes :- Replacement of spares will be measured and paid for separately under respective items of the schedule here-in-after as supply only.
Supply only new heating element of capacity 1.5KW/2KW with rubber gasket complete all as specified and directed.
Supply only thermostat suitable for storage type water heater complete all as specified and directed.
Supply only Pressure release valve 15mm dia suitable for geyser complete all as specified and directed.
Supply only Air release valve 15mm dia suitable for geyser complete all as specified and directed.
Supply only Non return valve 15mm dia suitable for geyser complete all as specified and directed.
Supply only Apparatus plate assembly suitable to fix thermostat, heating elements as of geyser and nuts etc complete all as specified and directed.
Supply only Fusible plug
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m depth and getting out in soft / loose soil complete all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm obtained from excavation complete all as specified and as directed.
Removing excavated soil to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point, complete all as specified and as directed.
M&L for 25 mm bore Medium grade GI tubing with all fitting and taking up or down existing tubing with all connections for taking into credit, complete to walls and ceilings or laid in floors complete all as specified and as directed by the Engineer-in-Charge.
M&L for 50 mm bore Medium grade GI tubing with all fitting and taking up or down existing tubing with all connections for taking into credit, complete to walls and ceilings or laid in floors complete all as specified and as directed by the Engineer-in-Charge.
M&L for 25 mm 3-layer PP-R Polypropylene random copolymer)concealed pipesSDR 7.4 (PN16) UVstabilized andantimicrobial fusionwelded havingthermal stability forhot & cold watersupply includingall PP-R plain & brass threaded polypropylene random fittings fixed complete towalls, ceilings or in floors etc.
M&L for 63 mm 3-layer PP-RPolypropylenerandom copolymer)concealed pipesSDR 7.4 (PN17) UVstabilized andantimicrobial fusionwelded havingthermal stability forhot & cold watersupply includingall PP-R plain &brass threaded polypropylene random fittings laid in trenches.
S&F in repair gun metal gate valve, painted finish, with forged brass spindle and iron wheel head, screwed both ends internally IS-778 marked, Class-2, for iron pipe of size 25mm bore complete all as specified and directed by Engineer in Charge.
S&F in repair gun metal gate valve, painted finish, with forged brass spindle and iron wheel head, screwed both ends internally IS-778 marked, Class-2, for iron pipe of size 50mm bore complete all as specified and directed by Engineer in Charge.
S&F in repair polythene float valve of size 25mm bore complete all as specified and directed by Engineer in Charge.
S&F in repair polythene float valve of size 50mm bore complete all as specified and directed by Engineer in Charge.
Taking out the old unservicable sluice valve and S&F Sluice Valve Class PN 1.6 100 mm dia conforming to IS 780 with flanged and drilled ends and of any pattern including necessary jointing and jointing materials complete (with rubber gasket, bolts and nuts etc., ) all as specified an as directed.
Screwing existing steel tubing bore 40 or 50 mm for alterations or additions (or lengthening screw on pipe to form connector)complete all as specified and directed by Engineer in Charge.
M&L for Rubber gasket joint for 100 mm dia DI pipe including other accesories, complete all as specified and as directed.
S&F in repair foot valve heavy duty with gun metal working parts of 50 mm dia including removal from suction pipe of the pump set, foot valve complete all as specified and directed by Engineer in Charge.
Flushing the bore well of size 150mm dia, 60 metre deep by means of Air compressor of capacity not less than 650 CFM at 150 PSI pressure for not less than four hours till the clear vwater comes out.
Repairs to submersible pumpset 3 HP capacity 3 Ph, 440 Volts including Lifting of pumpset from the borewell 60 mtrs deep , dismentling ,taking out old unserviceable spares and and replacement of spares and lowering into borewell after repair complete all as specified and directed by Engineer in Charge (Note: Rewinding and supply of Spares will be paid under relevant items here in after)
Rewinding of motor startor coil complete using super enameled copper wire of same gauge for coil against Item No. 92
Supply only Bush GM against Item No. 92
Supply only Thrust bearing against Item No.92
Supply only SS Coupling male and female against Item No. 92
Supply only Submersible cable 3 core, copper stranded 2.5 Sqmm flat type against Item No. 92
Repairs to electric driven pump set 10 HP capacity including removing from the foundation dismantling ,taking out old unserviceable spares and refixing the same after repair and replacement of spares on the existing position for complete all as specified and directed by Engineer in Charge (Note: Rewinding and supply of Spares will be paid under relevant items here in after)
Rewinding of motor startor coil complete as per IS-396 of 1953 using super enamelled copper wire of same gauge for coil against item No. 98
S&F Ball bearing (drive and non dirve end) against item No. 98
Supply only Cooling fan blade PVC against item No. 98
Supply only Terminal box with terminal connector against item No. 98
Supply only Gunmetal bush against item No. 98
Supply only Gland cup with bolts and nuts against item No. 98
Supply only GI flange drilled of suitable size with nuts , and washers including rubber gasket against item No. 98
Supply only Shaft mild steel against Item No. 98
Lifting of pumpset from bore well 76 metres deep and lowering into borewell and refixing same after repair complete all as specified and directed.
Supply and replacement of DOL Starter 3 phase, 440 Volts with relay range up to 10 HP, including taking down old unservicable one, complete all as specified and directed.
Supply and replacement of star delta starter, open execution type with single phase protection and relay range from 13 – 32 Amps, 3 Phase, 440 Volts including taking down old unservicable one, complete all as specified and directed.
S&F Ammeter size 96 mm square type, range 0 to 60 Amps and dismantling the existing unserviceable ammeter from the panel board complete all as specified and directed.
S&F voltmeter size 96 mm square type range 0 to 500 volts and dismantling the existing unserviceable voltmeter from the panel board complete all as specified and directed.
M &L for Cleaning of RCC Under ground sump of capacity 100000 ltrs using following steps/stages including arrangement of necessary T & P, labour and chemicals all as specified and directed by Engr-In-Charge. (a) Mechanised dewatering (b) sludge removal (c) High pressure cleaning (d) vaccume cleaning (e) Antibacterial spray (f) UV treatment. Note : Following guidelines will be followed while executing works under items (a) The cleaning will be done as per mechanised six stage process of RCC over head tank cleaning and results should be verified by the competent authorities. (b) Water required for the cleaning will be provided by the contractor at his own arrangements (c) The notice for the interruption of water supply will be intimated to the department in advance and efforts will be made by contractor to complete related work within 24 hrs to avoid prolonged breakdown of water supply in effected area. (d) M&L for removal of semi-solid/solid sludge extracted during cleaning and their disposal to suitable site are deemed to be included in quoted rate and will not be paid separately.
M&L for dismantalling of unserviceable water level indicator from Over head tank / UG Sump & S&F new water level indicator (Mechanical Type) on OH Tank / UG Sump. in position duly connected from plastic coated steel wire rope 8 mm dia passing over MS pulley 50 mm dia & hanging over calibrated scale on MS Sheet 3.15 mm thick including Painting of scale for letters with white colour over two coat of synthetic black paint and one primer coat on MS board with & including bracing, supports, clamps grouted on wall of tank at desiredc height and back plate etc fabricated from structural steel section with bolts, nuts, washers ,welding,bending cold or hot, drilling holes for bolts,in any shape or size as indicated or directed and inclusive of one primmer coat, one under and one finishing coat of red oxide.
M &L for Cleaning of RCC over head tank of capacity 100000 ltrs using following steps/stages including arrangement of necessary T & P, labour and chemicals all as specified and directed by Engr-In-Charge. (a) Mechanised dewatering (b) sludge removal (c) High pressure cleaning (d) vaccume cleaning (e) Antibacterial spray (f) UV treatment. Note : Following guidelines will be followed while executing works under items (a) The cleaning will be done as per mechanised six stage process of RCC over head tank cleaning and results should be verified by the competent authorities. (b) Water required for the cleaning will be provided by the contractor at his own arrangements (c) The notice for the interruption of water supply will be intimated to the department in advance and efforts will be made by contractor to complete related work within 24 hrs to avoid prolonged breakdown of water supply in effected area. (d) M&L for removal of semi-solid/solid sludge extracted during cleaning and their disposal to suitable site are deemed to be included in quoted rate and will not be paid separately.
S&F in repair CI Non Returning valve 80 mm dia conforming to IS 14845 PN 1.0 with flanged and drilled ends and of any pattern including necessary jointing and jointing materials complete (with rubber gasket, boltsand nuts etc ) complete all as specified and directed by Engineer in Charge.
M&L for preparation of old painted surfaces of LT panels and spray painting with two coats of synthetic enamel paint complete all as specified and directed.
Cleaning and removing of sludge/mud from the well , 6 mtr dia and 6 mtr depth including making necessary arrangement as required and removing the mud from the site to the place and put one coat of bacteria removal chemicals over a one coat of white wash as directed by the Engr-in-Charge.
S&F PP-R Gate valves (brass insert) as per requirement of the site of size 25mm
S&F PP-R Gate valves (brass insert) as per requirement of the site of size 63mm
S VENKATESAN
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .