Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹39.3 CrAccepted-Finance AT MALANI COMPLEX 58 KOTECHA NAGAR KALAVAD ROAD RAJKOT 360001 GUJARAT INDIA | RAJKOT | GUJARAT | 360001 | ₹39.3 Cr | L1 | Accepted-Finance Lowest rate found. |
Tender Value
₹37.2 Cr
EMD Value
₹47.2 L
Closing Date
30 Sept 2023, 2:00 pmClosed
The Exe.,Engg., PWD, WD-I, Daman.
The Multi Office Complex, PWD, 2nd Floor, Near Moti Daman Market, Moti Daman.
Installation of Medical Services and Systems for 300 Bedded Hospital at Marwad, Daman. (E-30244) (2nd call)
2023_DAMAN_3079_1
Tender Notice No.68/01/2023-24
Open Tender
Civil Works - Others
390 days
Daman District.
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,500
The Exe.,Engg., PWD, WD-I, Daman.
₹47.2 L
The Exe.,Engg., PWD, WD-I, Daman.
18 Oct 2023
1 Sept 2023
30 Sept 2023
1 Sept 2023
30 Sept 2023
1 Sept 2023
12 Sept 2023
Amount
Civil work
Medical Gas Pipe line System Supply, Installation, Testing and Commissioning of Copper pipe shall be as per standard BS: EN 13348:2016/ ASTM B819 standards, Solid drawn, seamless, deoxidized, non-arsenical, half hard (hard can be accepted only for sizes 54mm or more), tempered and degreased copper pipe conforming to the standard. All copper pipes shall be degreased & delivered capped at both ends of required sizes compliant to the Technical Specifications. copper pipes size as mentioned below: 108mm OD X 1.5mm thick, As per tender technical specification
Supply, Installation, Testing and Commissioning of Copper pipe shall be as per standard BS: EN 13348:2016/ ASTM B819 standards, Solid drawn, seamless, deoxidized, non-arsenical, half hard (hard can be accepted only for sizes 54mm or more), tempered and degreased copper pipe conforming to the standard. All copper pipes shall be degreased & delivered capped at both ends of required sizes compliant to the Technical Specifications. copper pipes size as mentioned below: 76mm OD X 1.5mm thick, As per tender technical specification
Supply, Installation, Testing and Commissioning of Copper pipe shall be as per standard BS: EN 13348:2016/ ASTM B819 standards, Solid drawn, seamless, deoxidized, non-arsenical, half hard (hard can be accepted only for sizes 54mm or more), tempered and degreased copper pipe conforming to the standard. All copper pipes shall be degreased & delivered capped at both ends of required sizes compliant to the Technical Specifications. copper pipes size as mentioned below: 54 mm OD X 1.2mm thick,As per tender technical specification.
Supply, Installation, Testing and Commissioning of Copper pipe shall be as per standard BS: EN 13348:2016/ ASTM B819 standards, Solid drawn, seamless, deoxidized, non-arsenical, half hard (hard can be accepted only for sizes 54mm or more), tempered and degreased copper pipe conforming to the standard. All copper pipes shall be degreased & delivered capped at both ends of required sizes compliant to the Technical Specifications. copper pipes size as mentioned below: 42 mm OD X 1.2mm thick,As per tender technical specification.
Supply, Installation, Testing and Commissioning of Copper pipe shall be as per standard BS: EN 13348:2016/ ASTM B819 standards, Solid drawn, seamless, deoxidized, non-arsenical, half hard (hard can be accepted only for sizes 54mm or more), tempered and degreased copper pipe conforming to the standard. All copper pipes shall be degreased & delivered capped at both ends of required sizes compliant to the Technical Specifications. copper pipes size as mentioned below: 28 mm OD X 1 mm thick, As per tender technical specification.
Supply, Installation, Testing and Commissioning of Copper pipe shall be as per standard BS: EN 13348:2016/ ASTM B819 standards, Solid drawn, seamless, deoxidized, non-arsenical, half hard (hard can be accepted only for sizes 54mm or more), tempered and degreased copper pipe conforming to the standard. All copper pipes shall be degreased & delivered capped at both ends of required sizes compliant to the Technical Specifications. copper pipes size as mentioned below: 22 mm OD X 1 mm thick, As per tender technical specification.
Supply, Installation, Testing and Commissioning of Copper pipe shall be as per standard BS: EN 13348:2016/ ASTM B819 standards, Solid drawn, seamless, deoxidized, non-arsenical, half hard (hard can be accepted only for sizes 54mm or more), tempered and degreased copper pipe conforming to the standard. All copper pipes shall be degreased & delivered capped at both ends of required sizes compliant to the Technical Specifications. copper pipes size as mentioned below: 15 mm OD X 1 mm thick, As per technical specification.
Supply, Installation, Testing and Commissioning of Copper pipe shall be as per standard BS: EN 13348:2016/ ASTM B819 standards, Solid drawn, seamless, deoxidized, non-arsenical, half hard (hard can be accepted only for sizes 54mm or more), tempered and degreased copper pipe conforming to the standard. All copper pipes shall be degreased & delivered capped at both ends of required sizes compliant to the Technical Specifications. copper pipes size as mentioned below: 12 mm OD X 1 mm thick, As per technical specification.
Supply, Installation, Testing and Commissioning of Gas Outlets Points/Terminal Units It should complies with HTM 02-01/NFPA 99C/DIN/EN/ISO-7396-1 standards. It should be US FDA / European CE Certified with 4 digit notified body number or American ETL/ American UL listed. Bidder must submit copy of UL Listed or ETL Listed Certificate or US FDA Certificate or notified body CE certificate as per medical devices regulations with four digit number on each item. Medical Oxygen, As per tender technical specification.
Nitrous Oxide as per (above Item. No.9 ) Specification & tender technical specification.
Medical Air 4 Bar as per (above Item. No.9 ) Specification & tender technical specification.
Surgical Air 7 Bar as per (above Item. No.9 ) Specification & tender technical specification.
Vacuum as per (above Item. No.9 ) Specification & tender technical specification.
AGSS as per (above Item. No.9 ) Specification & tender technical specification.
CO2 as per (above Item. No.9 ) Specification & tender technical specification.
Supply, Installation, Testing and Commissioning of matching Probe / Adaptor With one end suitable for Hose & other end suitable for terminal units as per technical specifications for Oxygen for Nitrous Oxide , for Compressed Air ( 4 Bar ), For Compressed Air (7 Bar) , For Vacuum, For AGSS/WAG .Fully complies to HTM 02-01/ NFPA 99 /EN/DIN/ISO 7396-1 It should be US FDA/ European CE with four digit notified body number American ETL/American UL Listed. Suitable for Oxygen, CO2, Nitrous Oxide, Compressed air 4 bar, compressed air 7 bar, DISS connection, vacuum. Medical Oxygen, As per technical specification.
Nitrous Oxide as per (above Item. No.16 ) Specification & tender technical specification.
Medical Air 4 Bar as per (above Item. No.16 ) Specification & tender technical specification.
Surgical Air 7 Bar as per (above Item. No.16 ) Specification & tender technical specification.
Vacuum as per (above Item. No.16 ) Specification & tender technical specification.
AGSS as per (above Item. No.16 ) Specification & tender technical specification.
CO2 as per (above Item. No.16 ) Specification & tender technical specification.
Supply, Installation, Testing and Commissioning of The Medical Gas Area Alarms + Area Valve Box should be digital and capable of monitoring up to 6/7 medical gas services by means of pressure sensors which detect deviations from the normal operating limits of either pressure or medical vacuum.. It Should Complies with HTM 02-01 / NFPA 99/EN/DIN/ ISO 7396-1 Standards. It should be US FDA/ European CE with four digit notified body number American ETL/American UL Listed.. 2 Gas (Oxygen Vacuum), As per tender technical specification.
3 gas ( Oxygen Vacuum , MA4) as per (above Item. No.23 ) Specification & technical specification.
4 gas ( Oxygen , Vacuum , MA4 , N20) as per (above Item. No.23 ) Specification & technical specification.
6 gas ( O2, VAC , MA4 , SA7 CO2, N20) as per (above Item. No.23 ) Specification & technical specification
Supply, Installation, Testing and Commissioning of Master Alarm panel 6 services (Oxygen, N2O, MA4 Air, SA7 Air, CO2 and Vacuum) It should be US FDA / European CE Certified with 4 digit notified body number or American ETL/ American UL listed. Complies with HTM 02-01 / NFPA 99C/EN/DIN/ ISO 7396-1 Standards. A test certificate shall be provided with each system detailing the results of the factory tests (EMC Test passed. Copy of certificate must be submitted). . As per Specification.
Supply, Installation, Testing and Commissioning of Fully Automatic Oxygen Control System 2000 LPM or more It should comply with HTM 02-01/NFPA 99C/DIN/EN/ISO-7396-1 standards. It should be US FDA / European CE Certified with 4 digit notified body number or American ETL/ American UL listed. A test certificate shall be provided with each system detailing the results of the factory tests (EMC Test passed. Copy of certificate must be submitted). As per technical Specification.
Supply, Installation, Testing and Commissioning of Oxygen Manifold (2x20) as per HTM 02-01/NFPA 99C/DIN/EN/ISO-7396-1 standards. It should be US FDA / European CE Certified with 4 digit notified body number or American ETL/ American UL listed. . As per Technical Specification.
Supply, Installation, Testing and Commissioning of Emergency Oxygen Supply System (2X10) as per HTM 02-01/ NFPA 99 /EN/DIN/ISO 7396-1 Standard and technical specifications. It should be US FDA/ European CE with four digit notified body number American ETL/American UL Listed.. As per Technical Specification.
Supply, Installation, Testing and Commissioning of Oxygen Flow meter with Humidifier Bottle as per HTM 02-01/ NFPA 99 /EN/DIN/ISO 7396-1 Standard, Fully complies to HTM02-01 BSEN 7396 shall, be CE marked as class IIb medical device 93/42/EEC. . The flow meters should be of 0-15lpm for oxygen and with inlet pressure 50-60psi. (4.5 bar). As per technical specification
Supply, Installation, Testing and Commissioning of Oxygen High Flow meter with Humidifier Bottle as per HTM 02-01/ NFPA 99 /EN/DIN/ISO 7396-1 Standard, Fully complies to HTM02-01 BSEN 7396 shall, be CE marked as class IIb medical device 93/42/EEC. The flow meters should be of 0-70lpm for oxygen and with inlet pressure 50-60psi. (4.5 bar). As per technical specification
Supply, Installation, Testing and Commissioning of Fully Automatic Manifold Control Panel for Nitrous Oxide 500 LPM or more as per HTM 02-01/ NFPA 99 /EN/DIN/ISO 7396-1 Standard. It should be US FDA/ European CE with four digit notified body number American ETL/American UL Listed.As per technical specification.
Supply, Installation, Testing and Commissioning of Nitrous Oxide Manifold (2x 6 ) as per HTM 02-01/ NFPA 99 /EN/DIN/ISO 7396-1 Standard and technical specifications.. It should be US FDA/ European CE with four digit notified body number American ETL/American UL Listed.Fully complies to HTM02-01 BSEN 7396 shall, be CE marked as class IIb medical device 93/42/EEC with four digit notified number specified.. As per technical Specification
Supply, Installation, Testing and Commissioning of Emergency Nitrous Oxide Supply System (2x 2) as per fully complies HTM 02-01/ NFPA 99 /EN/DIN/ISO 7396-1 Standard and technical specifications. It should be US FDA/ European CE with four digit notified body number American ETL/American UL Listed. As per technical Specification.
Supply, Installation, Testing and Commissioning of Fully Automatic Manifold Control Panel for CO2 500 LPM as per HTM 02-01/ NFPA 99 /EN/DIN/ISO 7396-1 Standard. It should be US FDA/ European CE with four digit notified body number American ETL/American UL Listed. A test certificate shall be provided with each system detailing the results of the factory tests (EMC Test passed, Adiabatic test passed. As per technical specification.
Supply, Installation, Testing and Commissioning of CO2 Manifold (2x 6) as per Fully complies to HTM 02-01/ NFPA 99 /EN/DIN/ISO 7396-1 Standard and technical specifications. . It should be US FDA/ European CE with four digit notified body number American ETL/American UL Listed. As per technical Specification
Supply, Installation, Testing and Commissioning of Emergency CO2 Supply System (2 x 2 ) as per fully complies HTM 02-01/ NFPA 99 /EN/DIN/ISO 7396-1 Standard and technical specifications. It should be US FDA/ European CE with four digit notified body number American ETL/American UL Listed. As per technical Specification
MEDICAL VACUUM SYSTEMS (Package unit) Supply, Installation, Testing and Commissioning of Central Medical Vacuum Plant of output of capacity minimum 7500 LPM as working and 7500 LPM as standby or Total design for minimum 15000 LPM as per relevant standard comprising of vacuum pumps, vacuum receiver, bacterial filters, pressure switches, system controls etc complete as per Technical Specifications.
MEDICAL AND SURGICAL AIR SYSTEM (PACKAGE UNIT) Supply, Installation, Testing and Commissioning of Central Medical Air Plant having a minimum capacity of 6000 LPM as working and 3000 LPM as standby or Total design for minimum capacity of 9000 LPM as per relevant standard comprising of compressed Medical Air system with air compressor, Air receiver tank, filtration , Dryer system, pressure switches, system controls etc complete as per Technical Specifications.
Supply, Installation, Testing and Commissioning of Vacuum Unit as perHTM 02-01/ NFPA 99 /EN/DIN/ISO Standard and technical specifications. It should be US FDA / European CE Certified with 4 digit notified body number or American ETL/ American UL listedTIt should be continuous vacuum regulator, compact, strong and ergonomic device. It should have manual adjustment of the vacuum gauge from -45degree to +45degree for a better visibility. Vacuum gauge should be protected by a plastic housing. It should have on/off switch-button providing a quick restoration of the pre-adjusted vacuum level. It should have central regulation knob with a free rotation at the end of the course (impossible blocking). It should have quick adjustment :2.5turns are enough to reach the maximum vacuum level. It should have vacuum levels :0-1000m/bar. The vacuum regulator should be 3-in-1 system. It should have a device with a metal outlet tubing nipple integrated in the body of the regulator for a better safety, emergency suctions can even be processed. It should be supplied with a 100ml safety jar equipped with a mechanical anti-over flow safety valve and single use antibacterial plastic filter upfront. The safety jar should be made of polycarbonate, autoclavable up to 134degree C and unbreakable. The safety jar should be fixed by an easy-click rotation. The safety jar should be able to rotate to avoid any pinch of the tubing. It should have a unit serial number laser engraved on the body of each vacuum regulator ensuring its identifications and traceability. And One Polysulphone collection jar of 1000ml with lid : It should be unbreakable and autoclavable upto 134º C must be fitted with an extremely simple anti overflow safety device, thereby ensuring easy maintenance. Should be totally transparent, they ensure perfect sucked liquid visibility. As per technical specification
Supply, Installation, Testing and Commissioning of Theatre Suction Unit as per Fully complies to HTM 02-01/ NFPA 99 /EN/DIN/ISO Standard and technical specifications. It should be US FDA / European CE Certified with 4 digit notified body number or American ETL/ American UL listed. shall, be CE marked as class IIb medical device 93/42/EE CE with four digit notified number specified It should be continuous vacuum regulator, compact, strong and ergonomic device. It should have manual adjustment of the vacuum gauge from -45degree to +45degree for a better visibility. Vacuum gauge should be protected by a plastic housing. It should have on/off switch-button providing a quick restoration of the pre-adjusted vacuum level. It should have central regulation knob with a free rotation at the end of the course (impossible blocking). It should have quick adjustment :2.5turns are enough to reach the maximum vacuum level. It should have vacuum levels :0-1000m/bar. The vacuum regulator should be 3-in-1 system. It should have a device with a metal outlet tubing nipple integrated in the body of the regulator for a better safety, emergency suctions can even be processed. It should be supplied with a 100ml safety jar equipped with a mechanical anti-over flow safety valve and single use antibacterial plastic filter upfront. The safety jar should be made of polycarbonate, autoclavable up to 134degree C and unbreakable. The safety jar should be fixed by an easy-click rotation. The safety jar should be able to rotate to avoid any pinch of the tubing. It should have a unit serial number laser engraved on the body of each vacuum regulator ensuring its identifications and traceability. And Two Polysulphone collection jar of 2000ml with lid : It should be unbreakable and autoclavable upto 134º C must be fitted with an extremely simple anti overflow safety device, thereby ensuring easy maintenance. Should be totally transparent, they ensure perfect sucked liquid visibility. As per technical specification
Supply, Installation, Testing and Commissioning of Duplex AGSS System 1500 lpm working and 1500 lpm as stand by of 50Hz as per Fully complies to HTM 02-01/ NFPA 99 /EN/DIN/ISO 7396-1 Standard and technical specifications. . It should be US FDA/ European CE with four digit notified body number American ETL/America UL Listed. The plant shall be a duplex configuration such that the vacuum supply is maintained in single fault condition. The stated volumetric flow rate shall be delivered with one blower on standby. The entire AGS Plant shall be skid mounted, fully assembled and factory tested as a complete system. Regenerative Blowers : Two equally sized regenerative blowers shall be provided. Blowers shall be oil-less, air cooled side channel regenerative type, suitable for both continuous operation and frequent start/stop. The motor shall be directly coupled to a fully enclosed impeller with contact free operation. As per technical specification
SITC of AGSS remote indicator as per Fully complies to HTM 02-01/ NFPA 99 /EN/DIN/ISO 7396-1 Standard and technical specifications . It should be US FDA/ European CE with four digit notified body number American ETL/America UL Listed. It should be 24 volt on/off room controller indicating ‘red’ plant failed, ‘amber’ duty pump failed and ‘green’ mains airflow on. As per technical specification
Supply, Installation, Testing and Commissioning of AGSS reservoir as per Fully complies HTM 02-01/ NFPA 99 C/EN/DIN/ ISO 7396-1 Standard. The AGSS Receiver is the practical solution for waste anaesthetic gas discharges and is designed as an integral part of any waste anaesthetic gas system. The receiver comes complete with a transfer system, outlet hose assembly, and user instructions, making it ready for immediate use. Transfer system- connects to the patient circuit or anaesthetic machine and comprises a 1.5 metre length of 30 mm clear disposable tube with a male 30 mm taper for connection to the side of the receiver, and a 30 mm female tapered breathing circuit connector. It should have air break which prevents suction from the disposal system being transferred to the patient -flow indicator. Under normal operating conditions the indicator should be visible. -gauze filter built into the top of the vessel to prevent gown fluff and other solid material from reaching and blocking the fixed extraction system. Receiver vessel for active anaesthetic gas scavenging systems body - anodised aluminium, powder coated Collar and Cap - anodised aluminium Indicator Window - clear acrylic Indicator Float - low density polyethylene. It should have flow indicator
Supply, Installation, Testing and Commissioning of AGSS Hose Assembly as per It should complies with HTM 02-01/ NFPA 99 C/EN/DIN/ ISO 7396-1 Standard. It conducts the waste gases to the fixed system outlet point and comprises a 4 metre length of reinforced clear tube (colour coded yellow and blue as per the standard). This is fixed to the top of the vessel allowing the tube unimpaired 360o motion to reduce strain on the unit, and tube occlusion. As per technical specification
Supply, Installation, Testing and Commissioning Medical gas hose assemblies as per Fully complies HTM 02-01/ NFPA 99 C/EN/DIN/ ISO 7396-1 Standard. and technical specifications. Medical gas hose assemblies shall comply with BS EN ISO 5359, BSEN 5682. BS EN 7396-2, BS EN 9170-1 NIST fittings compliant to BSEN ISO 18082PVC hoses and hoses containing phthalates are not acceptable. Hoses shall be colour coded throughout their length as specified in BS EN 5359 as follows: Medical oxygen - white Nitrous oxide – blue Medical and surgical air - black Vacuum - yellow, antistatic rubber tube All hoses shall incorporate an anti-static inner core. Hose shall be permanently secured to all fittings with stainless steel crimped ferrules, and shall incorporate a window to enable verification that the hose is fully secured onto the hose barb. Low pressure hose assemblies shall be in accordance with DINISO 5359 for coupling into outlet Colour coding must be in accordance with ISO 32. Angle type plug and NIST fittings must be in accordance with DIN 13260-2 and DIN EN 15908 respectively Hose assembly shall consist of a UL-listed high-pressure color-coded conductive hose with a DISS nut and gland on the upper end. Provide a DISS Hand-I-Twist check unit on the lower end for all services except AGSS/WAGD. Provide a Diamond quick-connect on the lower end for the Waste Anaesthesia Gas Disposal service
Supply, Installation, Testing and Commissioning of Bed Head Wall Panel 1200 mm as per fully complies HTM 02-01/ NFPA 99 /EN/DIN/ISO 7396-1 Standard and technical specifications. It should be US FDA/ European CE with four digit notified body number American ETL/America UL Listed. . Bidder must submit copy of UL Listed or ETL Listed Certificate or US FDA Certificate or notified body CE certificate as per medical devices regulations with four digit number on each item. It should be made up of Aluminium extrusion profiles with aluminium alloy 6063 temper T6. It should be manufactured from Virgin Aluminium’ no scrap added in aluminium). All sections are anodized aluminium except top plate. The top plate will be aluminium powder coating (high quality). It should have 4 Channel Channel-1 “ Separate row /separate channel” for gas outlet points with pre piping side entry (Pre Piped with 4nos. gas outlet points factory tested) Channel-2 “ Separate row /separate channel” for electrical sockets with pre wiring (*Pre wired with 6nos. electrical sockets factory tested) Channel-3 “ Separate row /separate channel” for data sockets and nurse call switch ( low voltage) Channel-4 “ Separate row /separate channel” for built in LED Light Built in high strength anodized aluminium rail of full length without any joint As per technical specification
Supply, Installation, Testing and Commissioning of Bed Head Wall Panel 1500 mm as per fully complies HTM 02-01/ NFPA 99 /EN/DIN/ISO 7396-1 Standard and technical specifications. It should be US FDA/ European CE with four digit notified body number American ETL/America UL Listed. . Bidder must submit copy of UL Listed or ETL Listed Certificate or US FDA Certificate or notified body CE certificate as per medical devices regulations with four digit number on each item. It should be made up of Aluminium extrusion profiles with aluminium alloy 6063 temper T6. It should be manufactured from Virgin Aluminium’ no scrap added in aluminium). All sections are anodized aluminium except top plate. The top plate will be aluminium powder coating (high quality). It should have 4 Channel Channel-1 “ Separate row /separate channel” for gas outlet points with pre piping side entry (Pre Piped with 4nos. gas outlet points factory tested) Channel-2 “ Separate row /separate channel” for electrical sockets with pre wiring (*Pre wired with 6nos. electrical sockets factory tested) Channel-3 “ Separate row /separate channel” for data sockets and nurse call switch ( low voltage) Channel-4 “ Separate row /separate channel” for built in LED Light Built in high strength anodized aluminium rail of full length without any joint As per technical specification
Supply, Installation, Testing and Commissioning Loanable Line Valves as per HTM 02-01/ NFPA 99 /EN/DIN/ISO 7396-1 Standard and technical specifications. It should be US FDA/ European CE with four digit notified body number American ETL/America UL Listed.. Degreased Medical Lockable Ball Valve with Pipe line assembly. Ball valves should be Lockable and ball-type. Pre Piped Degreased Ball Valve with pipe extension. It should be full-port design. It should be blow-out proof stem. It should be lockable valve. The Valve shall be ball-type design with a bronze body and chrome plated brass ball for sizes 1/2” to 4”. Seats shall be Teflon (TFE) and seals Viton. A blow-out proof stem shall be used and the valve shall have a maximum pressure rating of 600 psi [4,137 kPa]. Valves shall be operated by a lever-type handle requiring only a quarter turn from a fully open position to a fully closed position. Each valve assembly shall be washed and degreased for medical gas service. The valve shall be supplied in a sealed plastic bag to prevent contamination prior to installation. Complete Valve should be individually packed. 12mm As per technical specification.
15 mm as per (above Item. No.50 ) Specification & technical specification.
22 mm as per (above Item. No.50 )Specification & technical specification.
28 mm as per (above Item. No.50 ) Specification & technical specification.
42 mm as per (above Item. No.50 ) Specification & technical specification.
54 mm as per (above Item. No.50 ) Specification & technical specification.
54 mm as per (above Item. No.50 ) Specification & technical specification.
76 mm as per (above Item. No.50 ) Specification & technical specification
Supply, Installation, Testing and Commissioning of Liquid Medical Oxygen System, 13KL LOM Oxygen Cryogenic Tank, Vaporiser and PRV System with one time LMO license from PESO, fees for first 5 years. As per technical specification.
Central Sterile Supply Department Double Washer Disinfector - 250-300 liters/12 DIN capacity European CE Certified by Four Digit Notified - As per Technical Specifications of the Tender
Double Door Steam Sterilizers - 800 -900 Liters/12 DIN capacity European CE Certified by Four Digit Notified Body, Pressure Equipment Directive 97/23/EC and EN 285/EN 554 Standards. - As per Detailed Technical Specifications of the Tender
Ultrasonic Cleaner (50 ± 5 L) , Operating 40 Hz,US FDA certificate / European CE Certified
Rotary Heat Sealer with Roller Front Table European DoC, and DIN 58953-7:2008, ISO 11607-2 and EN 868-5 - As per Technical Specifications of the Tender
Double Door Plasma Sterilizer Low Temperature Sterilization European CE certified with Four Digit Notified Body, 48-60% H2O2 concentration - As per Technical Specfications of the Tender
TABLE TOP STEAM STERILIZER ,23 - 28 L Capacity, 5 Trays- As per Technical Specfications of the Tender
DRYING CABINET , 300 L capacity- As per Technical Specfications of the Tender
SPRAY GUN RINSER - As per Technical Specfications of the Tender
GAUZE CUTTING MACHINE WITH SS TABLE - As per Technical Specfications of the Tender
STAINLESS STEEL PASS BOX, DOUBLE DOOR- As per Technical Specfications of the Tender
CLOSED TRANSPORT TROLLEY - As per Technical Specfications of the Tender
STERILE TAPE DISPENSER - As per Technical Specfications of the Tender
Stainless Steel Baskets 1 STE - As per Technical Specifications of the Tender
Modular Operation Theater SITC of Wall Panel - As per Technical Specifications of the Tender
SITC of Ceiling panel - Hermentic Suspended Ceiling -As per Technical Specifications of the Tender
SITC of Laminar air flow ceiling - 1no. for each OT (inside OT work only): As per Technical Specifications of the Tender
Hermetically Sealed Sliding Door - As per Technical Specifications of the Tender
Hermetically Sealed Sliding Door with Lead Lining - As per Technical Specifications of the Tender(Ground and 2nd Floor -1 each)
SITC of Stainless Steel Storage Unit: As per Technical Specifications of the Tender
SITC of 2mm Flooring: As per Technical Specifications of the Tender
SITC of Dimmeble Peripheral light cum clean room luminaries: As per Technical Specifications of the Tender
SITC of Touch Surgeon Control Panel: As per Technical Specifications of the Tender
SITC of Medical Isolation Panel: As per Technical Specifications of the Tender
SITC of LED X-Ray View Panel: As per Technical Specifications of the Tender
SITC of Writing Board: As per Technical Specifications of the Tender
SITC of Inside OT electrical wiring and PVC conduting: As per Technical Specifications of the Tender
SITC of Stainless Steel Grill for Return and Supply inside each OT. - As per Technical Specifications of the Tender
SITC of Three Bay Stainless Steel Scrub Sink: As per Technical Specifications of the Tender.
SITC of Double Dome OT Light (Camera Prepared) with axis of 3rd Monitor Arm ceiling mounted with ceiling flange : Europeon Claass-1 or UL Listed or ETL Listed or USFDA Certified - As per Technical Specifications of the Tender
SITC of Centrally Mounted Camera: - As per Technical Specifications of the Tender
SITC of Medical Monitor with Monitor Arm: - As per Technical Specifications of the Tender
SITC of Recording System with 32"Monitor: As per Technical Specifications of the Tender
SITC of Imported Digital Display PACS/HIMS Medical Grade Monitor 54” Monitor: As per Technical Specifications of the Tender
SITC of Double Arm Motorised Surgeon Pendant - As per Technical Specifications of the Tender
SITC of Double Arm Motorised Anesthetist Pendant - As per Technical Specifications of the Tender
High End OT Table for Ortho OT- As per Technical Specifications of the Tender (2nd Floor)
High End Surgery OT Table- As per Technical Specifications of the Tender (Ground Floor - 2 , 2nd Floor- 1 )
High End Gyanec OT Table- As per Technical Specifications of the Tender (Ground Floor - 1 , 2nd Floor- 1 )
Ophthalmic OT Table (Remote Operated)- As per Technical Specifications of the Tender (2nd Floor)
AHU for each OT
Condensing Unit for each OT
Outside OT sterile coordior AHU unit
Control cabling from AHU to MOT control panel and associated sensors
Online UPS for each OT and 1 Standby UPS
Electrical Distribution Board with 12 MCB
Electrical Distribution Board with 16 MCB
Aluminum ducting with nitraile insulation
Electric Control panel
Medical Gas Pipe Line Interconnection
TVX and Dryer Filter
Copper Piping With insulation.Copper Refrigerant Piping with nitrile insulation class O
Electric & Control wiring. Control and transmission wiring between indoor and outdoor units
Micro-processor based humidity sensor & Display Panel
Micro-processor based Room temperature sensor & Display Panel
HEPA Filter Status Sensor & Display Panel
Pneumatic Tube System Hard- and Software components incl. power supply, PC, monitor, keypad and all necessary parts - Remote graphic visualization in real time - automatic transfer rate adjustment - dynamic route calculation, - Rerouting Time Profiles - Integration of system monitoring into the network - Dynamic carrier tracking in the intranet for RP-users via a web browser - graphical representation of transport routes of individuel transports - Real-time transport information, Active transports, Incoming transports - carrier administration - graphical representation of transport routes of individual transports(uTID) - RFID-Transponder for reading and writing physically information on the Transponderchip (datasheet must be attached to the offer) - Automatic redirection to the service station to reach a defined number of transports. - Automatic redirection to the cleining station to reach a defined number of transports. (Software description must be attached to the offer)
PTS-Station Bottom load sending and receiving NW 160, Compact station, Due to less space a maximum size of H / B / W in mm = 350 x 540 x 280 is not allowed to exceed Metal housing in RAL7035 with: - receiving basket - carrier shelf - sending storage for one carrier - pneumatic brake - LCD graphic display with 128x64 pixel (Q - Touch Screen) - electronic address list - menu supported service functions To minimize spare parts the identical electronics provide all PTS-devices incl. driving tube compounds, Fasteners and accessories; deliver and assemble (Dimensional drawing must be attached to the offer)
PTS-Station sending and receiving NW 160, Top loadingstation, (Front Load) Due to less space a maximum size of H / B / W in mm = 580 x 470 x 510 is not allowed to exceed Metal housing in RAL7035 with: - receiving basket - carrier shelf - electromagnetic lockable transparent front door - closed front door of the station in idle mode - Display and front door at the same height - simultaneously receiving and discharging of carriers if front door is open - To avoid crowded baskets, Station lower edge above ground at least 160 cm - sending storage for one carrier - pneumatic brake - LCD graphic display with 128x64 pixel - electronic address list - menu supported service functions To minimize spare parts the identical electronics provide all PTS-devices incl. driving tube compounds, Fasteners and accessories; deliver and assemble (Dimensional drawing must be attached to the offer)
PTS-Carrier NW 160 - 2x rotating slide lid - Slide lid 360 ° rotatable, suitable for right and left hander - loadable of cd/dvd - RFID-Transponder for reading and writing physically information - suitable for automatic unloading station
Two way diverter - Pneumatically tight diverter. Absolutely sealed with maintenance free Teflon bushings. Driving by cog/teeth belt. Blocking of the free branch.
PTS-Diverter NW160 Typ 3-way Due to less space a maximum size of H / B / W in mm = 470 x 800 x 370 is not allowed to exceed Metal housing in RAL7035 driving tube compounds, Incl. optical transmission sensor Belt drive including slip clutch To minimize spare parts the identical electronics provide all PTS-devices incl. driving tube compounds, Fasteners and accessories; deliver and assemble (Dimensional drawing must be attached to the offer)
Switching power pack for the power supply of the system - 230 Volt AC - input. 1 x 24 Volt DC output. Short circuit proof with electronic fusing . Performance - 120 VA, Protection type - 20 IP. OR as per OEMs Standard
Blower 400V~ FU-suitable Protection class: IP54 with: - electric blower control - integrated reversing machine - 02 Four Way Diverter and air diverter is not allowed incl. soundproof mounting and necessary accessories; deliver and assemble:
PTS-Driving Tube, PVC light grey Ral7000 building class BK 1, NW 160x3,2, inclusive sleeve, compounds, Fasteners and accessories; deliver and assemble:
PTS-Driving Tube Bend, PVC light grey Ral7000 building class BK 1, NW 160x3,2, R 800, 90°, inclusive sleeve, compounds, Fasteners and accessories; deliver and assemble:
PTS-Driving Tube, UPVC transparent; building class BK 1, NW 160x3,2, inclusive sleeve, compounds, Fasteners and accessories; deliver and assemble:
PTS-Driving Tube Bend, UPVC transparent building class BK 1, NW 160x3,2, R 800, 90°, inclusive sleeve, compounds, Fasteners and accessories; deliver and assemble:
PTS-twisted pair data cable with integrated power supply for the devices incl. mounting and necessary accessories; deliver and assemble:
Nurse call system : IP CONTROLLER_POE SWITCH : Supply ,Installation ,Testing and commissioning of System Switch having following features : SITC of VDE 0834 certified/ approved System Switch: The system switch forms a decentralised communications node for exchanging data between the connected system devices and the rest of the communications system, consisting of : - 1 x RJ45 socket, 100Mb IP Port (IEEE802.3 100BaseTX), galvanically isolated conforming to EN 60950 and VDE 0834; - 7 x RJ45 sockets, each for a 100Mb IP system port (IEEE802.3 100BaseTX) for connecting all IP capable system modules; - 1 x RJ45 socket, 100Mb IP Port (IEEE802.3 100BaseTX) for connecting communications, staff and ward terminals as well as control panel PCs or for redundant Connection.- Control LEDs for indicating the current operating state; - 2 x 2 x RJ45 sockets for connecting the I/O data buses capable of connection up to 125 Buttons, Patient Handset Etc with inbuilt Power supply to Buttons - Supervised 24VDC output for extrnal devices e.g. Lamp module - Also have the Netorking feature Layer 2 NSP Ethernate type 0x3000, IEEE 802.1p Priority, IEEE 802.1Q VLANs, RFC 768 UDP, RFC 783 TFTP Protocol (revision 2), RFC 793 TCP, RFC 826 ARP, RFC 854 TELNET, RFC 951 BOOTP, RFC 2236 IGMPv2.
Nurse Station(Staff Terminals) : Nurse Station Terminals (with LED Screen ): Distributor circuit board f. 2 DVI monitors and LED Screen for VDVI-IP module:
NURSE STATION TERMINAL ( UPTO 32 BEDS): Supply ,Installation ,Testing and commissioning of Nurse Station Terminal having following features :Nurse Station shall comprises of minimum 6“ large LC colour graphic display for displaying all details , a smash proof glass panel (to protect the sensitive display from unnecessary contact during cleaning and other processes) , Querying receiver for speaking discretely, Microphone and loudspeaker for hands-free speech (incl. volume control), automatic changeover between hands-free and discrete speaking , Electronic circuit board with controller and FlashProm, 100BaseTX interface to the system switch, PC interface to the communications control panel , 2.8m connection cable with an RJ45 connection plug, which is protected, from disconnection, for connecting to a connection module . The ward terminal shall display date and time, indication of all presence, all set reminedrs, indication of all calls in accordance with VDE0834. All call indications follow the priority and must display the exact location of the calls. The ward terminal shall be provided along with suitable connection module & back box
Patient Terminals - (NON VOICE): PATIENT HANDSET (NON VOICE) Supply ,Installation ,Testing and commissioning of Patient Handset - Without Speech having following features : SITC of VDE 0834 certified/ approved Patient Handset - Without Speech & Cradle - BT-B consisting of a plastic case in antimicrobial finish having - Call button with nurse symbol with integrated finder and reassurance light on the top end of the unit, - Membrane keypad in antimicrobial finish with integrated LEDS for operation, consisting of: - 1 call key, - 2 lighting keys - 2.80 metre connection cable with auto-disconnecting RJ45 connector plug. It shall be supplied with cradel for holding patient terminals.
BEDSIDE UNIT( NON VOICE) -For Single sharing beds : Supply ,Installation ,Testing and commissioning of connection module for Patient Terminal having following features : SITC of VDE 0834 certified/ approved bed head connection module for Patient Terminal for NON VOICE Connection module to connect patient handset shall consist of: - Mounting rail with board, 2 x RJ45 sockets for connecting the data bus - 1 x RJ45 socket marked in colour and with measures to ensure that the push button is correctly connected, including the auto disconnect mechanism i.e. intellifix technology, with antimicrobial coating /fininsh - 1 x 5 pole DIN socket for connecting a diagnostic device with disconnection call if required. The connection module automatically triggers the relevant call in the event of an alarm occurring. - 4 x RJ12 sockets (6 pole) for connecting additional devices - 1 membrane keypad with: – 1 call button (red) including a fi nder light / reassurance light, – 1 presence key (green) including control LED, - Fastening bracket made of plastic to attachment the plug module without using screws with counter sunk back box.
Toilet modules / Push Buton with Call and Cancel : Supply ,Installation ,Testing and commissioning of connection module for Patient Terminal having following features : 1 call button (red) including a fi nder light / reassurance light, - 1 presence button (green) incl. control LED, - 1 x RJ12 (6 pin) sockets for connecting to the data connection - Incl. an installation frame for screw-free attachment to an installation case
Toilet modules/ Toilet Emergency Unit/Basic Module : Basic pushbuttons for releasing calls with a pull cord, for individuals requiring assistance in situations with restricted mobility. Equipped with moisture-proof circuit board, cancel button and a locating and reassurance light status LED. The cancel button can be optionally configured as a green presence button.Intended for use in wet rooms Integrated locating and reassurance light Actuating the pull cord has the same effect as pressing a call button (red) Fast-exchange pull cord (approx. two meter) with snap hook Red grip with nurse symbol
LAMP ( ROOM ) INDICATOR/ Door Display Unit / IO Module :Supply ,Installation ,Testing and commissioning of Loop Powered Lamp ModuleSupply ,Installation ,Testing and commissioning of having following features : SITC OF VDE 0834 complied shall consist of: , Can be confi gured as a room call lamp, a direction lamp and as a ward lamp For optical indication of calls, presences and reminders in the relevent colors, conforming to VDE0834 and suitable for fi tting on to an installation case consisting of 5 light chambers: - 5 light chambers with light reflectors for homogenous illumination , - 1 light chamber equipped with 3 ultra light red LED’ - 1 light chamber equipped with 3 ultra light white LED’ - 1 light chamber equipped with 3 ultra light green LED’ - 1 light chamber equipped with 3 ultra light yellow LED’ - 1 light chamber equipped with 3 ultra light blue LED’ - Each light chamber conforms to the lighting strength from VDE0834, - The life expectancy of the
Installaton and commissioning charges
Laundry SITC of Barrier Washer Extractor- For washing cleaning and extraction: Capacity -50 kg, Electric Heated & Steam Heated Dual mode, with 2 opposed door ,loading door on dirty side and unloading door on clean side.
SITC of Drying Tumbler Capacity – 45 kg Gas Heated, Total Min capacity to dry 90-95 kg per Hour.
SITC of Flatwork Ironer (Calendaringm/C): Gas Heated, Front Feed Front Return -500X3300mm Flatwork Ironer and a maximum ironing surface for the utmost ironing quality
SITC of Flat Bed Press -Electric Heated Suitable for linen like uniform, room furnishing, personal garments, Bed sheets & Pillow Covers Head & Bed Size Dimensions of the universal plate - 1180X380X220 mm Steam heated,
SITC of Rectangular Vacuum Ironing Table :Size -1550 X 580 X950
SITC of Dry Linen Transportation Trolley-Capacity -50kg The dry linen trolley shall be fabricated out of Aluminium metal and should be good quality for the better movement and performance along with moving wheels
SITC of Mobile Folding Table -Dimensions: 4feetX2 Feet The folding table shall be specially designed for carrying rolling and folding of linen in the laundry. The frame of the table shall be fabricated out of MS welded construction with one bottom shelf for storage. Complete with heavy duty ball bearing for swivelling wheels. The table top shall be of polished Stainless steel.
SITC of Fresh Linen Storage Rack Size - 1200mmx460mmx1800mm 4 shelves; Made of Stainless Steel-AISI-304, Finished with Polishing.
SITC of Fresh Linen Transportation trolley Capacity -50kg The fresh linen trolley shall be fabricated out of Aluminium metal and should be good quality for the better movement and performance along with moving wheels
SITC of Laundry Scrub Station with 2 Sinks. 1) Stainless Steel Construction. 2) S.S Sinks with taps for wash and rinse using hot and cold water. 3) SS Scrubbing Board in between Sinks. 4) Underneath Shelf. Size- 1600x500x900 ht. 5) Geyser of 3Kw to be provided for Hot water
SITC of Hot Water System-Electric Geyser Capacity: 600 Litres per Hour This Hot water system would provide the hot water as per the capacity. 1) Glass Lined Tank for water heater use. 2) Anode with low level of maintenance. 3) Low flue gas temperature for higher efficiency. 4) Additional pressure and temperature valve for safety 5) Fully automatic spark ignition & Automatic Control system
SITC of Electric Boiler 200kg -Steam Output-200 Kg Per Hour
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid