Executive Engineer PWD RandB PROJECT DIVISION III
Office of the PWD RandB PROJECT DIVISION III JAMMU
Electrification for new room and allied works in Govt. qtr. 3 C at Gandhi Nagar, Jammu. CNO-654 NP
2026_PWDJK_303841_2
Short e-NIT No. 144 of 2025-2026 Dated 19-02-2026
Open Tender
Electrical Works
30 days
JAMMU
Please refer Tender documents.
2 documents required · 2 mandatory
₹600
Executive Engineer PWD RandB PROJECT DIVISION III
₹8,000
Office of the PWD RandB PROJECT DIVISION III JAMMU
6 Mar 2026
19 Feb 2026
27 Feb 2026
19 Feb 2026
26 Feb 2026
19 Feb 2026
23 Feb 2026
Wiring for light point/ fan point / exhaust fan point/ call bell point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, with modular switch, modular plate, suitable GI box earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc as required.
Supplying and fixing following Modular type switch/ socket on the existing modular plate and switch box including connection etc. as required. 5/6 amp switch
3 pin 5/6 amp socket outlet
15/16 amp switch
15/16 amp socket
Bell push
Supplying and drawing following sizes of FRLS PVC insulated copper conductor single core cable in the existing surface/recessed steel/PVC conduit as required of Approved brand. 1 x 1.5 sq. mm
1 x 2.5 sq. mm
1 x 4 sq. mm
1 X 6 sq.mm
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 25 mm
Supplying and fixing 5 amps to 32 amps rating 240/415 volts "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required of Approved Brand. Single pole upto 32 amp.
Supplying & fixing of following way single pole and netural, sheet steel, MCB distribution board, 240 volts, on surface/ recess complete with tinned copper busbar netural busbar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. 12 way (Double door)
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Supplying and fixing call bell / buzzer suitable for single phase, 230V, complete as required.
Supplying and fixing PVCbatten/ angle holder including connections etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover front on surface or in recess ,including providing & fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch ,connection etc .as required.
Supplying and fixing of twin core aluminium cable all along the wall surface unarmoured. 16 sq.mm
Supplying and fixing following rating 240/415 volts "C" curve, miniature circuit breaker suitable for inductive load of following poles Modular SPN/DP 32 A
Supplying and fixing following rating 240/415 volts "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. SPN 63 AMP
Providing and fitting of LED Bulbs 9W
Supplying and fixing of surface mounted 18/20 watt LED batten tube fiiting 4 feet long including connections etc as required warm/white
PVC tape
Supplying and fixing of 10 watt LED batten fitting 2 ft long including connections etc. warm/white
Providing and fixing ceiling panel light in false ceiling. 6" 12 Watt/ 15 watt
Supply, Installation , Commissioning and Testing of Hot & Cold Split Type air Conditioning Unit, Inverter Heat Pump type Heating and cooling Function Opertation -10deg C to 54deg C ( Heating range: -10 to 24 deg c, Cooling range: 20 to 54 degc) in 3 STAR Rating, with Dew Clean Technology (auto cleans the coil of inddor units), Stablizer inside ( 130 v to 285 v) operation,(Triple Display-Power consumption display in %,Automatic error code display & set/room temperature display), Power airflow duel flaps,Air Filteration -PM1.0,Co2 filteration,Anti corrosion- Blue fin coating Cooling capacity at 43 degc is 100%, ISEER - 4.39 & above, Air throw 52 ft ( 1.5 ton & 1.8 ton machines only),3D air flow,Min IDU sound level- 32 (dBA),(Warranty- Compressor-10 years,PCB-5 year,Total system warray-1 year) with Interconnecting copper pipe of 3 metres, Control cable of three metres of the following Capacities. 1.5 Ton with Cooling Capacity of 5.0KW Cooling/Heating
Rope / cove light strip
Providing and fixing of LED flod light of approved brand 30 watts warm/ white
Providing and fixing of Inverter 875 VA with batteries 150 AH complete with suitable trolly ISI Marked/ ISO Certified
Providing and fixing Fancy decorative light complete with 9 watts LED Bulbs.
Providing and fixing of hylem sheets of following specifications. 8''X5''
Please Enable Macros to View BoQ information
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.73 MB
BOQ_986871.xls
BOQ • 0.34 MB
Download all tender documents and submit your bid