Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹28.4 LAccepted-AOC | L-1 | Accepted-AOC Accepted | |
| 2 | Not Admitted-Finance NOT SPECIFIED | - | Not Admitted-Finance Not qualified for AOC |
Tender Value
Refer Docs
EMD Value
₹49,210
Closing Date
4 Jul 2022, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer
Water Supply and Sanitation Division No.2, Bathinda
Construction of 100 cum Capacity OHSR for Hostel Block for Boys and Girls Guest Houses Warden House No 24 No 750 Sqf Houses for Veterinary college at Rampura Phul District Bathinda
2022_WSS_87258_1
3105/21-06-2022
Open Tender
Civil Works
Item Wise
90 days
Work
Please refer Tender documents.
4 documents required · 4 mandatory
₹1,500
₹49,210
26 Dec 2022
25 Jun 2022
5 Jul 2022
25 Jun 2022
4 Jul 2022
25 Jun 2022
90 days
Electrical Items :
Excavation by mechanical means(JCB or Hydraulic excavator) in trenches for pipe lines with straight or open cutting in streets or open area including trimming and dressing sides levelling of beds of trenches to correct grade, cutting joint holes, refilling consolidation, watering, including the cost of dewatering of rain water, diversion for traffic, night signals. providing & fixing caution boards, crossing over trenches for access to the houses, watching, fencing, etc. and removal of surplus soil out side/inside the town involving lead upto 15 meter complete in all respect. i) All classes of soil except rocky a) 40x0.60x1.10 (Item No. 28.2)
Providing, Stringing out, cutting, Jointing and testing of ISI Marked D.I. Pipe (S&S) as per IS 8329 and laying the same in trenches to correct alignment and gradients, jointed with rubber tyton joints fitted complete including all cartage, cost of rubber ring. D.I. Pipe as per IS 8329 DI-K7 c) 150mm i/d pipe lines laid complete. (Item No. 28.7-B)
Proving & fixing ISI Marked Non-return valves flanged end class PN-1.0 as per IS:5312/2004 in pipe lines including jointing & cost of Nut Bolt , rubber insertion etc. complete. Note: If Non-return valves class PN-1.6 is used instead of class PN-1.0 , than 5% will be paid extra. Class PN-1.0 as per ISI with rubber Flap a) 80mm i/d (Item No. 28.31A)
Construction of One No. RCC circular type, O.H.S.R of 100000 ltrs. Capacity having height 24.00 mtr. upto FSL complete. with external RCC stair case with landing slabs at each staging RCC roof, ventilator single manhole cover,lightening conducter etc.complete as described in schedule No.3. Providing and fixing C.I D/F expansion joints or latest bell mouth and D/F puddle collars as per DWSS design on the basis of enclosed drawing. Duck foot bends, Conforming to ISI-13382 and D.I.K9 D/F sluice valve duly ISI marked (IS-14846-2000 or latest) one each with inlet, outlet and scour pipes, including providing and installing inlet,outlet, scour pipe and over flow D.I. double flanged pressure pipes cost in sand moulds horizontally as per IS 8329-2000 and latest duly ISI marked from bottom dome to duck foot bend and further up to 2.75 mtr. as per detail specification. TMT steel & painting of all complete shall be included in cost & P/F aluminium ladder inside the OHSR complete in all respect as per specifications.(The specifications & drawing are based on safe bearing capacity of soil is 8.75 tonne per Sqm. will be submitted by the contractor and no extra payment will be paid to contractor for this test. In case the safe bearing capacity of soil is less than 8.75 tonne per Sqm. The contractor shall submit his own design for foundation portion based on actual safe bearing capacity as per DWSS specifications. The difference in quantities from the standard drawing based on 8.75 tonne per Sqm safe bearing capacity will be paid as per CSR+ Prevailing Ceiling Premium including overflow haudi, supplying fixing and testing automatic electronic type water level indication system with gun metal float sensor and electrical cable suitable for three phase pump submersible/monoblock to be fixed on existing panel for OHSRs, including plinth ptotection etc. complete in all respects. (Item No. NS)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .