| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.9 LAccepted-AOC D1C 47A JANAK PURI NEW DELHI 110058 | NEW DELHI | DELHI | DELHI | 110058 | L1 | Accepted-AOC L1 Bidder | |
| 2 | L2₹29.9 L+₹33,095 (1.12%)Rejected-AOC | L2 | Rejected-AOC L2 Bidder | |
| 3 | L3₹31.0 L+₹1.4 L (4.76%)Rejected-AOC 6 341 RATAN VIHAR NANGLOI DELHI 110041 | DELHI | WEST DELHI | DELHI | 110041 | L3 | Rejected-AOC L3 Bidder | |
| 4 | L4₹32.4 L+₹2.8 L (9.42%)Rejected-AOC | L4 | Rejected-AOC L4 Bidder | |
| 5 | L5₹44.0 L+₹14.3 L (48.4%)Rejected-AOC | L5 | Rejected-AOC L5 Bidder |
Tender Value
Refer Docs
EMD Value
₹98,000
Closing Date
27 Jul 2021, 6:00 pmClosed
GE I RND DELHI
MILITARY ENGINEER SERVICES, GARRISON ENGINEER (I) RND, LUCKNOW ROAD, TIMARPUR, DELHI-110054
REPAIR/MAINT OF INTERNAL WIRING AND CONNECTED WORKS FOR JCB, DCDA, SAG, OTM, MD ACCN LASTEC, DESIDOC, CEPTAM, ISSA AND DTRL OF MHSU (I) OF METCALFE HOUSE AREA UNDER GE I RND DELHI.
2021_MES_447427_1
GE/RND-31/DLI/2021-2022
Open Tender
Civil Works
Item Rate
180 days
DELHI
Class D, Cat b(i)
2 documents required · 2 mandatory
₹500
Yes
GE I RND DELHI
₹98,000
Yes
9 Aug 2021
1 Jun 2021
29 Jul 2021
1 Jun 2021
27 Jul 2021
15 Jul 2021
Amount
Taking down carefully unserviceable aluminium point wiring for light/socket/power socket complete, including fixtures and fitting such as light fittings, switches, ceiling roses, pendents, regulators, socket (except light fittings etc) and making good distrubed surfaces on walls, ceiling, floors etc. complete all as specified and as directed.
M&L for one point wiring for lights/fans with PVC insulated FR LSH unsheathed copper cable of size 1.5 sqmm including earth wire of size 1.5 Sqmm in and including Concealed PVC conduit 20 mm dia including GI Flush sheet box 2.0 mm thick and PVC white modular Inner/Outer cover plate with frame, for light and fan/call bell including cutting chases for conduit where required and making good to wall and ceiling complete all as specified and as directed .
All as per item No 2.00 above but one bell point controlled by one switche.
All as per item No 2.00 above but one light point controlled by 02 nos two way switches.
All as per srl item No 2.00 above but for 5 pin socket outlet 5 Amp independent with other switch.
All as per srl item No 2.00 above but for 5 pin socket outlet 5 Amp on same board with other switch.
All as per srl item No 2.00 above but for 5 pin socket outlet 5 Amp independent but below the switch board in the same verticle plane.
M&L for one point wiring with PVC insulated FR LSH unsheathed copper conductor cable of size 1.5 sqmm including earth wire of size 1.5 Sqmm in existing concealed conduit including new GI flush sheet box 2.00 mm thick and modular top sheet top cover, for light and fan/call bell and including cutting chases and sinking where required complete all as specified and as directed for one light /fan point controlled by one switch 5A one way
All as per ser item No. 8.00 above but one 3 pin socket out let 5 Amps same board.
All as per ser item No. 8.00 above but one 3 pin socket out let 5 Amps on independent board.
M&L for one point wiring of with PVC insulated FR LSH unsheathed copper cable of size 4.0 sqmm including earth wire of size 4.0 Sqmm in Concealed PVC conduit 20 mm dia including GI Flush sheet box 2.0 mm thick and PVC white modular Inner/Outer cover plate with frame, for 15 amps power point including cutting chases for conduit where required and making good to wall and ceiling complete all as specified and as directed .
M&L for one point wiring of with PVC insulated FR LSH unsheathed copper cable of size 1.5 sqmm including earth wire of size 1.5 Sqmm in PVC Casing/Caping including GI Flush sheet box 2.00 mm thick and PVC white modular Inner/Outer cover plate with frame , for one light/fan/exaust fan /bell point and making good to wall and ceiling for one light/fan point/bell point controlled by one switch 5A one way complete all as specified and directed.
All as per ser item No. 10.00 above but one 3 pin socket out let 5 Amps independent.
All as per ser item No. 10.00 above one 3 pin socket out let 5 Amps same board.
M&L for one point wiring of with PVC insulated FR LSH unsheathed copper cable of size 4.0 sqmm including earth wire of size 4.0 Sqmm in PVC Casing /Caping including GI Flush sheet box 2.00 mm thick for modular and PVC white modular Inner/Outer cover plate with frame, for 15 amps power point including cutting chases for conduit where required and making good to wall and ceiling complete all as specified and as directed.
M&L for one point wiring of with PVC insulated FR LSH unsheathed copper cable of size 2.5 sqmm including earth wire of size 2.5 Sqmm in PVC Casing /Caping including PVC modular gang Box for 15 amps power point including cutting chases for conduit where required and making good to wall and ceiling complete all as specified and as directed.
S&F Modular switch 1 way 6A, 1 Module complete all as specified and as directed.
S&F modular switch 6 Amps 230V AC complete two way complete all as specified and as directed.
S&F Modular switch 1 way 16A, 1 Module complete all as specified and as directed.
S&F Modular socket 6A 2/3 pin combained 2 module complete all as specified and as directed.
S&F Modular socket 6A/16A- 2/3 pin combained 2 module complete all as specified and as directed.
S&F in repair of Switch Piano, Flush type single ploe,one way 5 Amp complete all as specified and as directed.
S&F in repair of Socket outlet 2 in 1, 3 pin, 5Amp complete all as specified and as directed.
S&F in repair of Switch Piano, Flush type single ploe,one way 15 Amp complete all as specified and as directed.
S&F in repair of Socket outlet 2 in 1,3pin, 5A and 15 amp flush type complete all as specified and as directed.
S&F in repair of PVC gang box for 15 Amps switch socket complete all as specified and as directed.
S&F in repair of white hylum laminated sheet 3mm thick including cutting, drilling with all accessories for fixing of switch/sockets complete all as specified and as directed.
S&F in repair of electronic fan regulator 240 V step type single pole complete all as specified and directed.
S&F in repair of fan step regulator, 120W, 2 Module complete all as specified and as directed.
S&F in repair of ceiling rose, surface bakelite 65mm x 50mm three terminals PVC polycarbonate complete all as specified and as directed.
S&F in repair of telephone socket jack RJ 11 With shutter complete all as specified and as directed.
S&F in repair of telephone cable in concealed PVC conduit including connecting in telephone socket complete all as specified and as directed.
S&F in repair flurorescent light tube 1x36 with LED Tube rod of 20 Watt disconnectioning existing wire from bi pin holder, diconnectioning existing blast, removng carefully existing tube and making connection for LED tube light, 20 Watt including supply and fixing 20 watt Ultra bright LED in same fitting, including necessary electric connection complete including twin core 1.5 sqmm flexible copper cable for connecting to ceiling rose all as specified and directed.
S&F in repair Surface and wall mounted LED batten, extruded aluminium housing provided for efficient heat dissipation with polycarbonate diffuser & integrated electronic driver.trica batten 230 volt, 50 Hz, 22 watt and twin core 1.5 sqmm flexible copper cable for connecting to ceiling rose complete all as specified and directed.
S&F in repair LED recess mounted Octane panel square type with Slim, compact, aluminium die cast edge lit panel. Recess mounted square fixture with opal diffuser and separate electronic driver. 230 volt, 50 Hz, 12 watt, 3000K including and twin core 1.5 Sqmm flexible copper cable for connecting to ceiling rose, including necessary alteration work in false ceiling to cover the blank space in false ceiling complete all as specified and directed.
S&F in repair CFL light to new LED recess mounting panel 2'×2' fitting 42 watt and making all electric connections including twin core 1.5 sqmm flexible copper cable for connecting to ceiling rose including necessary alteration work in false ceiling to cover the blank space in false ceiling all as specified and directed.
S&F in repair linear & compact LED mirror light 9 watt, including cable for making circuit and 9 watt LED tube complete and including twin core 1.5 sqmm flexible copper cable for connecting to ceiling rose all as specified and directed.
S&F in repair of unseviceable CFL light to new LED surface mounting panel 2'×2' fitting 36W and making all electric connections and including twin core 1.5 sqmm flexible copper cable for connecting to ceiling rose all as specified.
S&F in repair SPN DB 12 ways with 200 amps rated busbar 240 volt double door complete all as specified and directed.
S&F in repair SPN DB 8 ways with 200 amps rated busbar 240 volt double door complete all as specified and directed.
S&F in repair SPN DB 4 ways with 200 amps rated busbar 240 volt double door complete all as specified and directed.
S&F in repair TPN DB 6 ways with 200 amps rated busbar 415 volt double door complete all as specified and directed.
S&F in repair vertical type TPN DB 8 ways with 200 amps rated busbar 415 volt double door complete all as specified and directed.
S&F in repair vertical type TPN DB 12 ways with 200 amps rated busbar 415 volt double door complete all as specified and directed.
S&F in repair of MCB SP, C- curve, 230 volt 6 -32 amp 10KA complete all as specified and directed.
S&F in repair of MCB SPN 230 volt 40 amp 10KA 'C' Curve complete all as specified and directed.
S&F in repair of MCB SPN 230 volt 63 amp 10KA 'C' Curve complete all as specified and directed.
S&F in repair of MCB TPN 415 volt 63 amp 10KA 'C' Curve complete all as specified and directed.
S&F in repair of MCB TPN 415 volt 100amp 10KA 'C' Curve complete all as specified and directed.
S&F in repair of sheet metal enclosure, SPN type with two pin & earth plug and socket Industrial type DB with and including one MCB SP, C Curve type of capacity 25 Amp, 10 KA complete all as specified and directed.
S&F in repair Triple pole and earth encolsure with a three pin and earth plug with socket complete with one triple pole MCB 63 Amps 415 V.
S&F in repair of sub main wiring with four run of single core PVC insulated FRLSH stranded copper conductor cable of size 16 Sq mm and two run of 16 Sq mm PVC insulated FRLS copper conductor cable as earth continuity conductor drawn in and including rigid PVC conduit conduit concealed medium grade complete all as specified and directed.
S&F in repair of sub main wiring with four run of single core PVC insulated FRLSH stranded copper conductor cable of size 10 Sq mm and two run of 10 Sq mm PVC insulated FRLSH copper conductor cable as earth continuity conductor drawn in and in including rigid PVC conduit concealed medium grade complete all as specified and directed. Note: Any number of sum of cable shall be measured as one unit.
S&F in repair of sub main wiring with two run of single core PVC insulated FRLSH stranded copper conductor cable of size 6 Sq mm and one run of 6 Sq mm PVC insulated FRLSH copper conductor cable as earth continuity conductor drawn in and including rigid PVC conduit concealed medium grade complete all as specified and directed. Note: Any number of sum of cable shall be measured as one unit
S&F in repair of sub main wiring with two run of single core PVC insulated FRLSH stranded copper conductor cable of size 4 Sq mm and one run of 4 Sq mm PVC insulated FRLSH copper conductor cable as earth continuity conductor drawn in and including PVC rigid conduit concealed medium grade complete all as specified and directed. Note: Any number of sum of cable shall be measured as one unit.
S&F in repair of sub main wiring with two run of single core PVC insulated FRLSH stranded copper conductor cable of size 4 Sq mm and one run of 4 Sq mm PVC insulated FRLSH copper conductor cable as earth continuity conductor drawn in and in existing surface PVC conduit concealed medium grade complete all as specified and directed. Note: Any number of sum of cable shall be measured as one unit.
S&F in repair of sub main wiring with two run of single core PVC insulated FRLSH stranded copper conductor cable of size 2.5 Sq mm and one run of 2.5 Sq mm PVC insulated FRLSH copper conductor cable as earth continuity conductor drawn in and in existing surface PVC conduit concealed medium grade complete all as specified and directed. Note: Any number of sum of cable shall be measured as one unit.
S&F in repair of sub main wiring with two run of single core PVC insulated FRLSH stranded copper conductor cable of size 1.5 Sq mm and one run of 1.5 Sq mm PVC insulated FRLSH copper conductor cable as earth continuity conductor drawn in and in existing surface PVC conduit concealed medium grade complete all as specified and directed. Note: Any number of sum of cable shall be measured as one unit.
S&F in repair of 3 Pole MCCB, 100 Amp, 50 Hz, 415 V with rupturing capacity 16 KA.
S&F in repair of 3 Pole MCCB, 125 Amp, 50 Hz, 415 V with rupturing capacity 16 KA.
S&F in repair of 4 Pole MCCB, 160 Amp, 50 Hz, 415 V with rupturing capacity 36 KA.
S&F in repair of 4 Pole MCCB, 200 Amp, 50 Hz, 415 V with rupturing capacity 36 KA.
S&F in repair of Bell multi music type AC ,230 Volts, single phase comp as specified.
S&F in repair of bell push modular 6 Amp 1 module.
Material and Labour for earthing complete with GI earth plate electrode 600mmx600mmx6mm thick burried in ground vertically to a depth not less than 2.25meters below ground level with top edge of the earth plate at a depth not lesss than 1.5 meter below the ground level, earth plate surrounded 15cm thick layers of common salt and charcoal dust starting from ground below 15 cm of earth plate and up to 15 cm above the same. GI plate connected with GI wire 25x4mm by means of nuts, bolts and washers. GI strip laid in 40mm dia light grade GI pipe as protection from top of the plate up to test point (cost of protection pipe up to 7.5 meters from earth electrode will be included in the rates quoted by the contractor) as shown in electrical plat No. 03 of SSR Part-I with following:- (a) GI wire 25x4mm dia. (b) Watering pipe GI light grade 20mm dia from top of the earth electrode up to MS funnel with wire mesh embeded in floor of PCC earth pit. (GI Funnel should properly tightned on GI watering pipe and embeded in PCC floor of earth pit with open top suitable for watering of earth pits) (c) PCC earth pit 30x30x30cm constructed in PCC 1:2:4 type B1 exposed surfaces smoothly finished with 15mm thick cement mortar 1:6 plaster including RCC pit cover 25mm thick re-inforced with 8mm dia bars 75mm centre to centre both ways with 2 Nos MS handles of 12mm dia suitable for carrying of pit cover.
M&L for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or burried in ground or drawn in conduit/pipe or any other indicated situation for loop earthing etc as required 25x4 mm galvanised iron strip complete all as specified and directed.
M&L in for Chemical earthing SITC of copper bonded Rod/Earthing termination bonded steel earth rods of 3mtr minimum length, 17.2mm dia, interconnected with copper bonded flanges (Minimum copper bonding shall be 0.25mm) along with Rod to Conductor connectors, and other accessories as per IS 3043, NBC 2016, IEEE80, UL 467, CPRI tested at 25KArms along with 30 KG pure carbon based Earth Enhancement compound tested by NABL accredited lab for ROHS complying IEC 62561-7 in a sealed bag and inspection pit covers including taking down old one complete all as specified and directed.
S&F in repair of MCB distribution board double door vertical type made out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating, TPN 4 way. 415 volts with bus bar rating 200 Amps, dust and vermin proof and IP 43 - IK 09 protection suitable for incorporation of MCCB, including grouting in the wall, cutting & chasing etc complete all as specified.
S&F in repair of MCB distribution board double door vertical type made out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating, TPN 8 way. 415 volts with bus bar rating 200 Amps, dust and vermin proof and IP 43 - IK 09 protection suitable for incorporation of MCCB, including grouting in the wall, cutting & chasing etc complete all as specified and directed.
S&F in repair of water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc complete all as specified and directed. Note: Water heater storage shall be deposited to E/M store yard.
S&F in repair of exhaust fans heavy duty metallic AC single phase 230/ 240 V of size 300 mm sweep with louver 900 RPM complete all as specified and directed. Note: Exhaust fan shall be deposted to E/M store yard.
S&F in repair of exhaust fans Non metallic AC single phase 230/ 240 V of size 250 mm sweep with louver 900 RPM complete all as specified and directed. Note: Fan shall be deposted to E/M store yard.
S&F in repair ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) complete all as specified and directed. Note: Ceiling fan shall be deposted to E/M store yard.
S&F in repair of wall mounted fans 230 volts single phase oscillating 450 mm sweep high speed suitable for wall mounting complete all as specified and directed. Note: Wall mounted fan shall be deposted to E/M store yard.
S&F in repair of Pedestal fans 230 volts single phase oscillating 450 mm sweep high speed suitable for wall mounting complete all as specified and directed. Note: Pedestal fan shall be deposted to E/M store yard.
S&F in repair Capacitor 2.5 MFD complete
S&F in repair of T5 14 Watt tube rod complete.
S&F in repair of CFL 18 Watt cross pin type complete
S&F in repair of CFL 36 Watt four pin type complete
S&F in replacement of Electronic ballast 2X36 Watt complete.
S&F in replacement of Electronic ballast 2X28 Watt for T5 fitting complete.
S&F Copper strip 20 x 3.15mm with saddles and fixing screws etc. for roof conductors and down conductors above ground
S&F in repair LED 20 Watt fitting batten with decorative end cap complete with aluminium housing & integral electronic driver with tube 20 watt complete including connection with 1.5 Sqmm 2 core flexible copper cable complete all as specified and directed.
S&F in repair of rigid non-metallic PVC conduit 25mm dia including of boxes (junction/terminal) all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc complete all as specified and directed.
GAURAV ASSOCIATES
M/s Wazer Enterprises
ASHISH GARG AND COMPANY
Surjit and Sons
dee een enterprises
DHARAMRAJ BUILDERS & ENGINEER
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .