Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | l1₹25.6 LAccepted-AOC | l1 | Accepted-AOC Awarded | |
| 2 | L2₹31.4 L+₹4.9 L (18.7%)Rejected-AOC | L2 | Rejected-AOC Rejected | |
| 3 | L3₹34.9 L+₹8.5 L (32.0%)Rejected-AOC FLAT NO 151 BLOCK NO 1 DIAMOND SQUARE CGHS LTD PLOT NO 13A SECTOR 6 DWARKA NEW DELHI 110075 | NEW DELHI | SOUTH WEST DELHI | DELHI | 110075 | L3 | Rejected-AOC Rejected | |
| 4 | L4₹38.5 L+₹12.1 L (45.7%)Rejected-AOC | L4 | Rejected-AOC Rejected | |
| 5 | L5₹40.9 L+₹14.5 L (54.7%)Rejected-AOC PLOT NO 32 FF SHIVAJI ENCLAVE NEW DELHI 110027 | NEW DELHI | NEW DELHI | DELHI | 110027 | L5 | Rejected-AOC Rejected |
Tender Value
Refer Docs
EMD Value
₹87,000
Closing Date
14 Oct 2021, 6:00 pmClosed
GE (P) AF Gurgaon
GE (P) AF Gurgaon Near Atul Kataria Chowk, Gurgaon
GE (P) AF/GUR-54/2021-22 REPAIR/MAINT OF EXTERNAL ELECTRIC, STREET LIGHT, SECURITY LIGHT INCLUDING OTHER CONNECTED WORKS AND ANNUAL/MAINTENANCE CONTRACT FOR FIRE FITTING, FIRE ALARM, AMR ELECTRIC ENERGY METERS AND OTHER MISC ITEMS IN 13 BRD AND 16 BR
2021_MES_475763_1
GE (P) AF/Gur-54/2021-22
Open Tender
Miscellaneous Works
Item Rate
270 days
GE (P) AF Gurgaon
All as specified in NIT
10 documents required · 10 mandatory
₹500
GE (P) AF Gurgaon
₹87,000
Yes
17 Nov 2021
16 Sept 2021
16 Oct 2021
16 Sept 2021
14 Oct 2021
30 Sept 2021
Amount
M&L for AMC for single phase AMR meter software hosting, GPRS Charges, meter calibration testing with multimeter, RF network monitoring and trouble shooting and repair/replacement of meter parts with manufactruing defect complete all as specified and as directed by Engr-in-charge (AMC for 430 Meter/ per month for 09 Months).
M&L for AMC for three phase AMR meter software hosting, ,GPRS Charges, meter calibration testing with multimeter, RF network monitoring and troubleshooting and repair/replacement of meter with manufactruing defect complete all as specified and as directed by Engr-in-charge.(AMC for 74 Meter/ per month for 09 Months).
Comprehensive monthly maintence of auto fire alarm system installed in 16 BRD AF Stn Palam. The detail scope of work consists of the following :- (i) Cleaning inspecting, checking and repairing if required all the equipments of fire detection system. (ii) Operational test of all the equipment of fire detection system in presence of rep of users and Engr-in-charge. (iii) The contractor shall submit test report regarding functioning of all the equipments duly signed by contractor, users rep and Engr-in-Charge on monthly basis. (iv) The maintenance shall be carried out through manufacturer representative or his authorised Rep. (v) Emergency visit shall be carried out when called in addition to the normal monthly maintenance in case of any failure in the system due to any cause without additional cost. (vi) Material required for replacement shall be measured and paid separately under respective items of this schedule as 'Supply and fixing' and labour component for the same is not included in comprehensive maintanance contractor shall quote the rate accordingly. (vii) Testing of entire fire alarm system and rectification of fault complete to the entire satisfaction of engr-in-charge all as specified and directed .
Supply and installation in replacement of response indicator lamp complete all as specified and as directed.
Supply and installation in replacement of 12 volt 7 AH maintenance free battery complete all as specified and as directed. Make - Exide /Ameron/ Luminous/ Amco
Taking down of old unserviceable optical type smoke detector and supply, fixing and testing of detectors complying with and type certified to EN-45 adjustable type smoke detector Photo electric / Optical with base with self built intelligence as per IS: 11360 complete all as specified and directed . Make Cooper/Honeywell/Ravel/Apollo
Supply and fixing in replacement of mother board suitable for Fire alarm system complete all as specified and directed. Of existing Make : Agni or equivalent as approved
Supply and fixing in replacement of Power Supply card suitable for Fire alarm system complete all as specified and directed. Of existing Make : Agni or equivalent as approved
Supply and fixing in replacement of manual call point resettable type of existing make complete all as specified and directed.
Supply and fixing in replacement of electronic sounder cum strobe of existing make, size and capacity complete all as specified and as directed.
Supply and fixing in replacement of Repeater Panel 08 Zone of existing make, size and capacity complete all as specified and as directed.
Supply and fixing in replacement for 1.5 sqmm single core PVC insulated sheathed ISI marked FRLS copper conductor multi stranded 1100 volt grade cable drawn through existing conduit connecting and testing all as specified and directed. Make: Kalinga/ Polycab/ Finoles / Havells
Supply and fixing in replacement of Heat Detector with Base complete all as specified and as directed. Make : Apollo/ Honeywell/Ravel/ Copper
Comprehensive monthly maintence of Fire Hydrant system installed 16 BRD AF Stn Palam. The detail scope of work consists of the following :- (i) Cleaning inspecting, checking and repairing if required all the equipments of fire hydrant system. (ii) Operational test of all the equipment of Fire Hydrant system in presence of rep of users and Engr-in-charge. (iii) The contractor shall submit test report regarding functioning of all the equipments duly signed by contractor, users rep and Engr-in-Charge on monthly basis. (iv) The maintenance shall be carried out through manufacturer representative or his authorised Rep. (v) Emergency visit shall be carried out when called in addition to the normal monthly maintenance in case of any failure in the system due to any cause without additional cost. (vi)Testing of entire piping network and rectification of leakage as requirement at site complete to the satisfaction of engr-in -charge and all as directed. (viii) Material required for replacement shall be measured and paid separately under respective items of this schedule as 'Supply and fixing' and labour component for the same is not included in comprehensive maintanance contractor shall quote the rate accordingly. (viiI) Checking of fire hyrant system and rectification of fault all as specified and directed by Engineer-In - Charge
Comprehensive monthly maintence of auto fire sprinkler system installed in 16 BRD AF Stn Palam. The detail scope of work consists of the following :- (i) Cleaning inspecting, checking and repairing if required all the equipments of fire sprinkler system. (ii) Operational test of all the equipment of fire sprinkler system in presence of rep of users and Engr-in-charge. (iii) The contractor shall submit test report regarding functioning of all the equipments duly signed by contractor, users rep and Engr-in-Charge on monthly basis. (iv) The maintenance shall be carried out through manufacturer representative or his authorised Rep. (v) Emergency visit shall be carried out when called in addition to the normal monthly maintenance in case of any failure in the system due to any cause without additional cost. (vi)Testing of entire piping network and rectification of leakage as requirement at site complete to the satisfaction of engr-in -charge and all as directed. (vii) Material required for replacement shall be measured and paid separately under respective items of this schedule as 'Supply and fixing' and labour component for the same is not included in comprehensive maintanance contractor shall quote the rate accordingly. (viii) Checking of sprinkler system and rectification of fault and live testing by generating heat and bursting sprinkler at particular area complete all as specified and directed by Engineer-In - Charge
Supply and fixing in replacement of sprinkler Quick / Early response type as per IS 15105 / TAC guide lines, 79 degree temperature rating pendant type complete all as specified and directed.
Supply and fixing in replacement of Pressure switch of existing make and capacity complete all as specified & directed
Supply and fixing in replacement of stainless steel Single headed hydrant valve 63 mm dia, ISI marked of existing make complete all as specified and as directed.
Supply and fixing in replacement of RRL hose pipe ISI marked 15 mtr length, type A complete all as specified and as directed.
Supply and fixing in replacement of stainless steel Male Coupling of existing make complete all as specified and as directed.
Supply and fixing in replacement of stainless steel Female Coupling of existing make complete all as specified and as directed.
Supply and fixing in replacement of Short stainless steel pipe of existing make complete all as specified and as directed.
Supply and fixing in replacement of brass Nozzle for 20 mm pipe of existing make complete all as specified and as directed.
S&F for external hose box (in repair) made of 18 gauge MS Sheet 800X 600X250mm with double door with 4 mm thick glass and door frame made of 16 gauge MS sheet painted fire red out side and brilliant white inside yard complete all as specified and directed.
Supply and fixing in replacement of MS ERW pipe C class of 150 mm dia including jointing and testing as per manufacturer's instructions complete all as specified and as directed.
Supply and fixing in replacement of MS ERW pipe C class of 100 mm dia including jointing and testing as per manufacturer's instructions complete all as specified and as directed.
Supply and fixing in replacement of MS ERW pipe C class of 80 mm dia including jointing and testing as per manufacturer's instructions complete all as specified and as directed.
Supply and fixing in replacement of GI pipe C class of 25 mm dia including ISI marked GI fittings and testing complete all as specified and as directed.
Supply and fixing in replacement of GI pipe C class of 20 mm dia including ISI marked GI fittings and testing complete all as specified and as directed.
Supply and fixing in replacement ISI Marked, of approved quality, 150mm size cast iron non butterfly valve, both ends flanged jointed and tested including taking down old valve complete all as specified and directed of make Zoloto/L&T / Kartar.
Supply and fixing in replacement ISI Marked, of approved quality, cast iron 150 mm Sluice valve,PN 1.6 both ends flanged jointed and tested including taking down old valve complete all as specified and directed of make Zoloto/ Kirloskar/ Leader/Kartar.
Supply and fixing in replacement ISI Marked, of approved quality, cast iron 100 mm Sluice valve, PN 1.6, both ends flanged jointed and tested including taking down old valve complete all as specified and directed of make Zoloto/ Kirloskar/ Leader/Kartar.
Supply and fixing in replacement ISI Marked, of approved quality, cast iron 80 mm Sluice valve, PN 1.6, both ends flanged jointed and tested including taking down old valve complete all as specified and directed of make Zoloto/ Kirloskar/ Leader/Kartar.
M&L for 1.5 sqmm 3 core PVC insulated unsheathed, FRLS multistranded copper conductor cable, 1100V grade complete al as specified and directed.
M&L for removing of lubricating oil from chamber and oil filter chamber of the diesel driven pump and cleaning of oil chamber & filter chamber thoroughly to remove all types of deposits and supply & filling of new lubricant oil SAE 15 W/40 W at required level complete all as specified and as directed.(Indian oil /BPL).
Supply and fixing in replacement of Element lub oil filter complete all as specified and as directed. Make:Mico/Fuel guard/Kirloskar/ Cummins/ Bosch
Supply and fixing in replacement of Fuel filter complete all as specified and as directed. Make:Mico/Fuel guard/Kirloskar/ Cummins/ Bosch
Supply and fixing in replacement of Coolant filter complete all as specified and as directed. Make:Mico/Fuel guard/Kirloskar
Supply and fixing in replacement of Element Air cleaner complete all as specified and as directed. Make:Mico/Fuel guard/Kirloskar/ Cummins/ Bosch
M&L for 4.00 sqmm 3 core PVC insulated unsheathed , FRLS multistranded copper conductor cable, 1100V grade as per IS 1554 (Part-1) drawn through and including ERW steel conduit of 20mm dia duly painted complete all as specified and as directed by Engineer-in-Charge.
Taking out motor from the system carrired out motor to work shop , Rewinding of Motor Rating 50-60 HP with copper enameled wire, refixing and testing the motor complete all as specified and as directed by Engineer-in-Charge.
M&L for Spray Painting of Pump with Motor capaicity 60 HP with synthetic enamel paint including preparation of surfaces complete all as specified and as directed by Engineer-in-Charge.
M&L in Spray Painting of Jockey Pump with Motor capaicity 10 HP with synthetic enamel paint including preparation of surfaces complete all as specified and as directed by Engineer-in-Charge.
M&L in spray Painting of Pump with DG Set capaicity 50 HP with synthetic enamel paint including preparation of surfaces complete all as specified and as directed by Engineer-in-Charge.
M&L in replacement of Battery lead with Brass terminal complete of appropriate size as per site complete all as specified and as directed by Engineer-in-Charge.
M&L in replacement of 5000 Ltr Triple layer ISI marked PVC Tank including tank neeples of 40 to 50mm size and taking down existing unserviceable tank complete all as specified and as directed by Engineer-in-Charge. Make : Sintex or as specified in list of makes.
M&L in replacement of 25 mm Gun Metal gate Valves complete all as specified and as directed by Engineer-in-Charge. Make: Kartar/ Zoloto/Leader.
M&L for Painting to150 mm pipe with synthetic enamel paint including preparation of surfaces complete all as specified and as directed by Engineer-in-Charge.
M&L for Painting to100 mm pipe with synthetic enamel paint including preparation of surfaces complete all as specified and as directed by Engineer-in-Charge.
M&L for Painting to 80 mm pipe with synthetic enamel paint including preparation of surfaces complete all as specified and as directed by Engineer-in-Charge.
M&L for Painting to 200 mm pipe as in header with synthetic enamel paint including preparation of surfaces complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing in replacement ISI Marked, of approved quality, 150mm cast iron non return valve, both ends flanged jointed and tested including taking down old valve complete all as specified and directed. Make : Kartar/Leader/Kirloskar.
Supply and fixing in replacement ISI Marked, of approved quality, 100mm cast iron non return valve, both ends flanged jointed and tested including taking down old valve complete all as specified and directed. Make : Kartar/Leader/Kirloskar.
Supply and fixing in replacement ISI Marked, of approved quality, 80mm cast iron non return valve, both ends flanged jointed and tested including taking down old valve complete all as specified and directed. Make : Kartar/Leader/Kirloskar.
Supply and fixing in replacement of Heavy duty threaded / welded MS or GI Flange with rubber gasket 150 mm complete all as specified and as directed.
Supply and fixing in replacement of Heavy duty threaded / welded MS or GI Flange with rubber gasket 100 mm complete all as specified and as directed.
Supply and fixing in replacement of Heavy duty threaded / welded MS or GI Flange with rubber gasket 80 mm complete all as specified and as directed.
Supply and fixing in replacement ISI Marked, of approved quality, 150mm cast iron Foot valve, with flanged jointed and tested including taking down old valve complete all as specified and directed. Make : Kartar/Leader/Kirloskar.
M&L for Cleaning of 25000 Gallon Tank with 6 Stage Cleaning Method STAGE 1: Dewatering the water with Mechanical electric Pump STAGE 2 : Clean the sluge from wall and floor of sump STAGE 3: High pressure cleaning with special pump STAGE 4: Suction with Industrial Vaccum Cleaner STAGE 5 : Anti bactrial Spray on wall and Floor of Sump( Test Certificate Of Chemical Must be Provided That chemical is safe for Humans) STAGE 6: UV Radiation for disinfect from the bactrial envoirment (Note: This work done by Specialist Agenceis of water treatment) complete all as specified and as directed.
M&L for Cleaning of 5000 Ltr Tank with 6 Stage Cleaning Method STAGE 1: Dewatering the water with Mechanical electric Pump STAGE 2 : Clean the sluge from wall and floor of sump STAGE 3: High pressure cleaning with special pump STAGE 4: Suction with Industrial Vaccum Cleaner STAGE 5 : Anti bactrial Spray on wall and Floor of Sump( Test Certificate Of Chemical Must be Provided That chemical is safe for Humans) STAGE 6: UV Radiation for disinfect from the bactrial envoirment (Note: This work done by Specialist Agenceis of water treatment) complete all as specified and as directed.
Comprehensive monthly maintence of 3 X 30 KVA UPS system installed in 13 BRD AF Stn Palam. The detail scope of work consists of the following :- (i) Execute diagnostics and physical checks. (ii) Examine, clean, test, all equipment as required and repair parts as and when required. (iii) Measurement of UPS parameters like input/output voltage, frequency, current, frequency, room temperature etc. (iv) Battery Parameters like voltage, current and other relevant parameters. (v) Ensure dust free and controlled temperature conditions. (vi) The corrective maintenance may require multiple visits to site (vii) Check all Equippment LED LCD display board. (viii) Check MCB/MCCB (ix) Check battery fuse Note : Response time shall not be more than 24 hours from the time of receipt of complaint on any working day between 9 AM to 6 PM in case of delay penality of Rs.1000/- per day shall be charged from contractor's dues.
Excavation in trenches in soft/loose soil not exceeding 1.50 Mtrs wide and not exc. 1.5 Mtr deep and getting out for taking out/laying cable, poles &stay etc complete all as specified and as directed by Engr-in-Charge.
Demoliton of Concrete of any description and in any position not otherwise specifically provided complete all as specified and as directed by Engineer-in-charge.
Returning, filling in including spreading leveling, watering and well ramming in layers not exc 25 cm thick after the cable have been laid tested complete all as specified and as directed by Engineer-in-Charge.
Removal of excavated surplus soil to a distance not exc. 50 Mtrs and depositing where directed at a level not exc 1.5 Mtr above the starting point complete all as specified and as directed by Engr-in-charge.
M&L for sand cushioning to under ground cable provided with layer of sand (8cm deep before laying the cable and 15 cm deep after laying the cable and punned down to 18cm, complete all as specified and as directed by Engr-in-charge.
M&L for brick laid in trenches for cable protection of burnt clay sub class ‘B’ complete laid dry flat, complete all as specified and as directed by Engr-in-charge.
Laying old serviceable bricks (retrieved under item 62 of Sch ‘A’, complete all as specified and as directed by Engr-in-charge.
M&L complete for driling hole hard standing / road for laying of pipe for protection of cable etc by means of manual booklet and without disturbing the top surface or cutting and making good the disturbed surface to the existing if any complete all as specified and directed by Engineer-in-charge.
Supply and laying GI tube light grade 40 mm bore complete all as specified and directed by Engr-in-charge. Make - Bansal/Jindal/ITC.
Supply and lay or fixing or passing through pipe cable XLPE (FRLS) with aluminium conductor with heavy duty stranded,1100 volts size of 16 Sqmm 2 Core including taking out old U/S cable complete all as specified and as directed. Note :- XLPE insulated pvc sheathing (heavy duty) armoured cable with aluminium conductor for working pressure up to and including 1100 volts to IS -7098 (Part-I) for pvc insulated cables with following :- (a) Cable shall have fire retardate low smoke (FRLS) compound added to it in the inner sheathing and out sheathing as per IEC 754 (part-I) IEC-60332 part-2 IFEE 383 ASTM 2x43 and ASTM 2X63 flame retardate compound (PR) as per EIC specification. (b) Inner sheathing shall be of extruded PVC. (c)Heat resisting PVC shall also be added to extruded inner and outer sheathing. (d) Cable shall also be supplied with sequences hal marking at every meter as the outer sheathing. (e) ultra violet radiation resistances compounded comprising ton ASTMG-53. (f) anti rodent and antitermite compound added. (g) pvc compounds of various grades as IS-5831. (h) compaction conductors shall be shaped and arrangement for the same with be on the cable
All as per item No. 71 but size 16 Sqmm, 4 Core .
S&F time switch type Alpharex3 D 21 astro, complete all as specified and directed by Engr-in-Charge. Make : Legrand Cat Part No.412654 or equivalent in Siemens/L&T
Supply and fixing in replacement 40 amps TP power contactor, complete all as specified and directed by Engr-in-Charge. Make - Legrand Cat Part No-412549 or equivalent in Siemens/L&T)
Supply and fixing in replacement 32 amps TPN MCB, complete all as specified and directed by Engr-in-Charge. Make - Legrand/Siemens/Schneider
Supply and fixing MCB SP 10 to 32 amps, complete all as specified and directed by Engr-in-Charge. Make : Legrand/Siemens/schiender
S&F 2.5 Sqmm three (03) core stranded PVC insulated copper conductor FR cable for connection of fittings, complete all as specified and directed by Engr-in-Charge. Make: Plaza/Havells
Taking down existing old street light panel /feeder box comprising of MCCB & switch fuse unit of any capacity and size including bus bar, ammeters, voltmeters etc after disconnecting all cable connection and removing from site complete all as directed.
S&F street light panel /feeder box made out of MS/CRCA sheet 3.15mm thick with MS angle iron frame of size 40x40x6mm out door type front door opening with locking arrangement slinting roof and size of panel/feeder pillar box is 0.6mx0.45 and 0.35 m with out legs including necessary pcc cutting and fixing with pcc 1:3:6 of size 0.3mx0.3mx0.2m for 04 nos legs including necessary insulators and 04 nos copper bus bar of size 30mmx5mm capacity, provn of inlet and outlet cables with glands and earth connecting lead etc complete and connection of all incoming and out going cable using aluminium terminal sockets/lugs duly crimpled and necessary two coats of paints with approved colour and grade of first quality synthetic enameled paint over a coat of red oxide primer including necessary preparation of surfaces all specified and testing complete including the following :- (i) S&F MCCB 4 pole 415 volts 125 amps 16 KA - 01 No. Make Legrand /Siemens/schiender (ii)S&Fmodular indicator lamp LED type -1 set (R,Y,B). (iii)S&F time switch type Alpharex3 D -21 astro Legrand CAT No 412654 =01 No (iv)Supply and fixing 40 amps TP power contactor Make -Legrand Cat No-412549 =01 No (v)Supply and fixing 32 amps TPN MCB Make - Legrand/Siemens/schiender =01 No (vi)Supply and fixing 6-32 amps sp MCB Make - Legrand/Siemens/schiender =06 Nos (vii)Supply and fixing single phase preventer Make -L&T=01 No
Supply and fixing LED street light fitting of capacity 60 watts ,cool white complete with drivers and all accessories and making all necessary connection including taking out of old unserviceable one, complete all as specified and directed by Engineer-in-Charge. Make : Havells/Bajaj/PHILIPS/ Crompton
Supply and fixing LED street light fitting of capacity 90 watts ,cool white complete with drivers and all accessories and making all necessary connection including taking out of old unserviceable one, complete all as specified and directed by Engineer-in-Charge. Make : Havells/Bajaj/PHILIPS/ Crompton
Supply and fixing 150 watt energy , saving environmental friendly, long life exclusive innovative die-cast aluminium IP65 flood light with high power LEDs as light source, suitable for highlighting architectural features or retail spaces, including taking out of old unserviceable one, complete all as specified and directed by Engineer-in-Charge. Make : Havells/Bajaj/PHILIPS /Crompton
Supply and fix replacement of Highly efficient high power LED flood light without lens , pressure die cast aluminium housing, reflector and enclosed with toughened glass Capacity 200 Watt . IP 66, complete all as specified and as directed by Engr-in-charge. Make : Havells/Bajaj/PHILIPS /Crompton
Supply and fixing replacement of LED flood light of capacity 300 watts ,cool white complete with drivers and all accessories and making all necessary connection including taking out of old unserviceable one, complete all as specified and directed by Engineer-in-Charge. Make : Havells/Bajaj/PHILIPS /Crompton
Supply and fixing 9 watts LED bollards square shape, integral decorative with opal acrylic with IP 65 protection light fitting including necessary connections and taking out of old unserviceable one., complete all as specified and directed by Engineer-in-Charge. Make - Bajaj / Philips /Havells /Crompton
Supply and fixing LED post light 45 watt made in die cast aluminium body and with clear toughened glass diffuser and IP -65 Protection complete including necessary connection complete all as specified and directed by Engineer-in-Charge, Make : Havells/Bajaj/PHILIPS
Supply and fixing LED post top light 40 watt made in cast aluminium spigot housing with decorative clear opal acrylic diffuser and IP -65 Protection including necessary connection complete all as specified and directed by Engineer-in-Charge. Make : Havells/Bajaj/PHILIPS
S&F in replacement of driver for LED light fitting of capacity 60W to 90W for any make fitting as per matching to existing type including necessary connection complete all as specified and directed by Engineer-in-Charge. Make : Havells/Bajaj/PHILIPS
S&F in replacement of driver for LED light fitting of capacity 120W to 150W for any make fitting as per matching to existing type including necessary connection complete all as specified and directed by Engineer-in-Charge. Make : Havells/Bajaj/PHILIPS
S&F in replacement of driver for LED light fitting of capacity 40 to 45W for any make fitting as per matching to existing type including necessary connection complete all as specified and directed by Engineer-in-Charge. Make : Havells/Bajaj/PHILIPS
M&L for Preparation of old painted exposed surface of steel tubular LT poles 9 mtr long with street light brackets etc complete, painting and numbering of poles with existing size and type as under:- (i)from bottom up to 1.2 mtr height one coat of black synthetic enamel high glow paint make berger (ii) 1.2mtr to 1.30mtr height one coat of red & blue luminous paint/tape. (iii)1.30 mtr height to top of the pole two coats of aluminium paint.
Supply & Fix Street Steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-31 (9.0 metres long) complete with foundation all as specified and as directed by Engineer-in-charge.
S&F Off load Change over switch with sheet metal enclosure type 1000 amps 4 pole 415 Volts, making all necessary connections with suitable thimbles including taking out of old unserviceable one, complete all as specified and directed by Engineer-in-Charge. Make :Havells/Legrand/HPL
M&L for earthing in replacement of with galvanized mild steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 Mtr below ground level) with top edge of earth plate not less than 1.5 Mtrs below ground level connected to GI strip 32x6mm as earth lead by means of nuts, bolts, thimbles, chuck nuts, washers of GI or steel, including PCC (concrete chamber) shall be PCC 1:3:6 type C-1 using 20mm graded stone aggregate, with fair finish internal surface of concrete chamber shall be given 15mm thick plaster in CM 1:4, funnel with wire gauge mesh, 80 mm thick RCC pit cover 320 mm x 320 mm of RCC 1:2:4 type B-1 using 20 mm graded stone aggregate reinforced with XPM, JALLI and charcoal dust and common salt all as shown in electrical plate No 3 of MES SSR Part-I (2009) and specified including provision of GI strip protected by 40 mm dia medium grade pipe and watering pipe shall be 20mm bore medium grade, and including all excavation and earth work & connecting the earthing to an earthing test point complete all as specified & directed by Engr-in-Charge.
M&L for PCC 1:3:6 type B2 using 40mm grade stone aggregate as in copping of electric pole or making good of disturbed surface complete all as specified and as directed by Engineer-in-charge.
M&L for cement concrete type B1 (1:2:4) (using 20mm graded aggregate) as in coping of poles even and smooth finishing using extra cement etc all as specified and as directed.
Supply & Fixing in replacement of NATURE SWITCH-02 (sensor along with pre-dawn switching off timer, 4-8 hrs) & NS-INDOOR (sensor for Lux level based switching of outdoor/semi-indoor lights). Make:- Nature switch or equivalent in HPL/L&T/EE.
Note:- The amount of Rs 81,198.00/- against Schedule of Credit on Page No 114 shall be deducted from the total amount quoted against Sch 'A' while deriving the Contract Sum for Acceptance.
Satish Kumar Gupta
BRIJ MOHAN LAL AND CO.
M/S MG GROUP
Singh Associates
M/S Satyam Associates
High Tech Metal India
SHREE RAM BUILD TECH
Vipul Construction
Rahul Enterprises
stage.html
html • 0.08 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .