Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | FIRST₹37.0 LAccepted-AOC H NO 502 B BLDG WELWORTH PARADISE PANCARD CLUB ROAD OPP MARBEL SOCIETY NEAR DHANKUDE VASTI BANER PUNE MH 411045 | PUNE | PUNE | MAHARASHTRA | 411045 | FIRST | Accepted-AOC BEING LOWEST | |
| 2 | SECOND₹39.0 LRejected-Finance SITE NO 29 30 1ST CROSS NAGAPPA REDDY LAYOUT KAGGADASPURA CV RAMAN NAGAR BANGALORE 560093 | BENGALURU URBAN | KARNATAKA | 560093 | SECOND | Rejected-Finance BEING NOT LOWEST |
Tender Value
₹42 L
EMD Value
₹84,000
Closing Date
13 Mar 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE AF MARATHAHALLI
GE AF MARATHAHALLI WIND TUNNEL ROAD, KEMPAPURA, YEMALUR POST, BANGALORE. PIN- 560037
PROVISION OF WATCH TOWER AND CERTAIN SANCTIONED WORKS AT SDI UNDER GE AF MARATHAHALLI BANGALORE
2024_MES_636571_2
8667/E8
Open Tender
Civil Works
Item Rate
270 days
GE AF MARATHAHALLI
AS PER ENIT
7 documents required · 7 mandatory
₹500
GE AF MARATHAHALLI
₹84,000
Yes
2 May 2024
10 Feb 2024
18 Mar 2024
10 Feb 2024
13 Mar 2024
24 Feb 2024
Amount
Taking down Chowkhats or frames but with shutters (without taking off shutters from the frame) exc 1.5 sq. M but n exc 4 sq. M each and removal from site all as specified and directed.
Dismantling wall and ceiling boards (fibre, pulp, insulation etc.) and boarding any thickness, including cover fillets and removal out side of MoD land/Air Force Unit area without paying any extra etc. complete all as specified and directed.
Cutting openings, through brick walls of cement mortar for door, window and other openings or enlarging existing openings. converting window into door openings, etc. or cutting out defective brick work for under-pinning, including providing, fixing and removing shoring, cleaning and stacking bricks, removing surplus serviceable bricks, hard-core, etc to store and rubbish not exc. 50m complete all as specified and directed.
Demolition of brickwork or stone/boulder masonry, built in cement mortar, complete all as specified and directed.
Dismantling boarding, any description, fixed in any position with screws complete all as specified and directed.
Dismantling of aluminium partition for carrying out floor works and shifting/refixing of aluminium partition after complete the floor work as specified and directed (Any item missing / further required to be arranged by contractor, to make the partition in good / sound position on refixing. The cost of those items shall be deemed to be included in the rate quoted).
Dismantling floor, hearth or wall tiling including cement mortar bedding including backing/rendering/plaster/screed etc. if any, removing rubbish off the premises all as specified and directed.
S&F Vitrified tiles light shade 10 mm thick (square/rectangular) polished, area of each tiles not exceeding 0.36 sqm in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15 mm thick screed in cement mortar (1:4) set and jointed complete all as specified and directed.
S&F Virified Ceramic tiles 10 mm thick (square/ rectangular) polished,as in skirtings etc set and jointed in neat cement slurry and pointed in white or coloured cement to match vertical surfaces including 10 mm rendering as in backing coat in cement mortar 1:3 complete all as specified and directed.
M&L for Pre-cast cement concrete 1:2:4 Type B-1(20mm graded crushed stone aggregate) block masonry with solid blocks, exc. 10 cm in width laid in cement mortar (1:4) and setting in mortar, complete all as specified and directed.
M&L Rendering 10 mm thick on fair faces in cement mortar 1:6 of brick work or concrete surfaces to be finished even and smooth (without using extra lime or cement) complete all as specified and directed.
S&F Powder coated Anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc (minimum thickness of powder coating 50 micron) and fixing/finished with past on gap of the surface in contact with stone masonary wall/brick wall complete all as specified and directed.
S&F Providing and fixing Powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors, windows, ventilators and partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required cluding cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws, all omplete as per architectural drawings and the directions of Engineer-in-charge complete all as specified and directed.
S&F 5.5 mm thick tinted sheet glass, ordinary quality and glazing with oil putty in square exc 0.5 sq. m in each panel fixed to alluminium frame works with neccessary rubbber bedding complete all as specified and directed.
M & L for 12mm thick Prelaminted particle board, interior grade prelaminated both sides with decorative choice laminations fixed with screws to timber frame work, all as specified and directed.
S&F Aluminium extruded section body, Door closer hydraulically regulated, deisignation No.3, universal type, suitable for door shutters of 851 to 1000mm in width and of weight between 61 to 80 kg and fixed, complete all as specified and directed.
S&F 4 levers aluminium mortice lock, brass vertical type, size 100 mm complete all as directed by Engr-in-Charge.
S&F false ceiling grid of size 600 x 600 mm system using hot dipped galvanized steel section with precoated capping, main tee of size 24x32 mm having 0.27mm thick at every 1200mm centre to centre, cross tee of size 24x27 mm having 0.25mm thick at 600mm centre to centre and wall angle of size 19x19 mm having 0.35 mm thick fixed to the periphery of the wall, and suspended at every 1200mm centre to centre in both directed using 2.00 mm thick GI wire and fixing 600 x 600 x 16 mm mineral fibre tegular edge ceiling tiles of RH90 complete all as specified and as directed.
M&L for preparation of new surface/undecorated surfaces of walls and applying two coats of Oil bound distemper over a coat of priming on plastered and other surfaces with alkali resistant priming paint complete all as specified.
M&L for preparation of old surface/undecorated surfaces of walls and applying one coats of Oil bound distemper on old plastered surface complete all as specified.
Excavation over areas, n.exc.1.5m deep and getting out in hard / dense soil concrete all as specified and directed.
Excavation over areas, exc 1.5 mtr but n.exc.3.0 m deep and getting out in hard / dense soil, concrete all as specified and directed.
Excavation in trenches, n exc 1.5 m wide and n exc 1.5 m in depth for foundation for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and getting out complete all as specified and directed.
Material & labour for cement concrete 1:4:8 Type D-2 (using 40 mm graded crushed stone aggregate) in foundation, filling and mass concrete all as specified and directed.
M&L for formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides of soffit (if any) of foundation and plinth beams, and similar work vertical or batter for rough finished surface all as specified and directed.
M&L for RCC (design mix), M 30 (20 mm graded crushed stone aggregates) as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc; basement slabs, under-reamed piles and mass concrete concrete all as specified and directed.
M&L for formwork to sides of pillars, posts, struts, piers, columns, and stanchions concrete all as specified and directed.
M &L for RCC ,M 25 (design mix) with 20 mm graded crushed stone aggregates as in Columns, pillars, piers, posts and struts concrete all as specified and directed.
M&L for Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc. Rough finished surfaces of concrete, complete all as specified and directed.
M &L for RCC ,M 25 (design mix) with 20 mm graded crushed stone aggregates as in Beams, cantilevers, bressummers, lintels over 1.5m span all as specified and directed.
M&L for Formwork to staircases with sloping or stepped soffits including risers and stringers (excluding landing) complete all as specified and directed.
M &L for RCC ,M 25 (design mix) with 20 mm graded aggregates as in Chullah hoods; stairways (except spiral staircases) including steps (square or spandril), string pieces, carriages, etc., complete, any section straight or winding, but excluding landings; RCC water tanks upto 1500 litres complete all as specified and directed.
M & L for Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work (Horizontal or sloping) complete all as specified and directed.
M & L for RCC ,M 25 (design mix) with 20 mm graded crushed stone aggregates as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed.
M & L for Formwork to fins, louvers, fascia complete all as specified and directed.
M & L for RCC ,M 25 (design mix) with 20 mm graded crushed stone aggregates as in Fins, fascias, louvres, parapets, and railings exc. 60cm in height, newels, balustrade, and the likecomplete all as specified and directed.
M & L for Formwork to chullah hoods, chajjas, troughs and similar items including edges complete all as specified and directed.
M & L Formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/ PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide complete all as specified and directed.
M & L for RCC M 25 (design mix) with 20 mm graded aggregates as in Chajja complete all as specified and directed.
M&L TMT mild steel bar 10mm dia and over cut to length bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips all as specified and directed.
M&L TMT mild steel bar but 6mm to 8mm dia. cut to length bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips all as specified and directed.
M&L TMT mild steel bar 5mm dia and over upto and including 10mm dia in strirrups spaces and binders all as specified.
Material and labour for precast cement concrete block masonry with solid blocks in PCC 1:3:6, type C1 using 20mm graded aggregate exceeding 10cm width and setting in cement mortar 1:4, complete all as specified and directed.
Material and labour for providing precast cement concrete solid building blocks or slabs 10cm thick (with plain or interlocking joints as directed) in walls in PCC 1:3:6, type C1 using 20mm graded aggregate and setting in CM 1:4, complete all as specified and directed.
M & L rendering 5 mm thick in ceilings on fair faces of concrete surfaces in CM 1:3, finished even and smooth without using extra cement concrete all as specified and directed.
M&L Rendering 10 mm thick on fair faces in CM 1:6 of brick work or concrete surfaces to be finished even and smooth (without using extra lime or cement) complete all as specified and directed.
M&L Rendering 15 mm thick Cement plaster in CM 1 :4, (5 mm thick with WP compound/liquid as per manufacturer’s instructions over 10 mm thick cement plaster in two layers) complete all as specified and directed.
Supply only water proofing compound conplast X 421 IC of FOSROC chemcial (Indian limted) complete all as specified and directed.
Material and Labour for preparation of newly plastered surfaces of Ceiling and applying three coats of white wash Complete all as specified and directed.
M&L for preparation of new surface/undecorated surfaces of walls and applying two coats of Cement Base Paint of approved tint over a coat of priming on plastered and other surfaces with alkali resistant priming paint complete all as specified.
M&L for preparation of new surface/undecorated surfaces of walls and applying two coats of Oil bound distemper over a coat of priming on plastered and other surfaces with alkali resistant priming paint complete all as specified.
M&L for Mirror polished Machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing laid over 15 thick screed bed with cm 1:4 complete all as specified.
M&L for Mirror polished Machine cut Kota stone slab 20-25mm thick in riser of steps, skirting, dado and pillar laid over cement screed and jointed with ditto as complete all as specified including 10mm thick backing plaster finished fair & rough to receive tiles.
M&L for Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors;ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified.
Preparation of new surfaces of steel and iron surface of any description, not otherwise descriped over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide complete all as specified
Material and labour for roof treatment as follows:- (a) Applying one coat of SBR latex based bond coat using Latex Plus of Berger or equivalent after mixing with water and cement in ratio of 1:4:7 to improve the bonding between residual and PU coat. Allow to dry bond coat for 4-6 hours before applying PU coat and surface to be cleaned before applying PU coat.(b) Applying two coats of single component, cold applied, water based polyurethane modified acrylic dispersion with highly elastic and UV resistant water proofing treatment to the roof with HS PU Roofkoat of Berger or Equivalent at 0.6 kg/per Sqm for each coat without dilution confirming to ASTM D 6083-97a (Standard Specification for Liquid Applied Acrylic Coating Used In Roofing)Each coat should allow to dry 4-6 hours and sandwiching 40gsm Geo-textile between two coats. Spread 40gsm Geo textile over 1st coat when coat is wet condition The component shall have a density of 1.25 to 1.3kg/per Litre, having tensile strentgh of 1.5N/mm2, having elongation of 350% with solid content not less than 60% in 2 coats . SRI value should be more than 100. the quoted rate shall include surface prepartion,repair the crack in mother slab by chasing with cutting machine and fill the same with polymerized mortar in CM 1:4 admixed with latex agent of reputed manufacture, making coving at Junction, bore packing, treatment of construction joints completely as per manufacurer's specification and direction of the Engineer In Charge.Make: Berger / ASIAN / STP / SIKA or Equivalent NOTE:- The above treatment shall be got carried out by the authorised applicator of the manufacturer approved by the GE.
M&L for Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and directed.
M&L for moorum/red bajri filling in floors or paving, laid in layers n.exc15 cm thick, spred, levelled and rammed including watering all as directed.
M & L for broken stone or boulders hard core of gauge n exc 63mm deposited spread and leveled in layers n.exc 15 cm thick watered and rammed to true surface complete all as specified and directed.
M&L for 75 mm thick PCC 1:4:8 (40 mm graded crushed stone aggregate) Type D-2 as in sub- base of floor all as specified and directed.
M&L for 30 mm thick Cement concrete type B- 0, 1:2:4 (using 12.5 mm graded crushed stone aggregate) as in flooring/hardstanding and complete all as specified.
M&L for treating the backfill in contact with foundation at the rate of 7.5 litres of emulsion per square metre of vertical surface (Area of the sub structure in contact with backfill to be measured)complete all as specified and directed.
M&L for treating the top surface of filled earth at the rate of 5 litres of emulsion per square metre of surface.
S&F Steel windows with side hung shutters including projecting type hinges with steel handle, and steel Mpeg stay, complete with glazing bars, dovetailed or welded.
S&F 4 mm thick sheet glass, ordinary quality and glazing with oil putty in square n exc 0.5 sq. m in each pane complete all as specified.
Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out hard/dence soil complete all as specified and directed.
M&L for 100 mm thick PCC 1:4:8 (40 mm graded aggregate) type D-2 as in sub- base of floor complete all as specified and directed.
M&L 50 mm thick sand filling under floor or in foundation including watering & consolidation complete all as specified and directed.
M&L Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade with grey cement and no pigment complete all as specified and directed.
Removing excavated material not exc. 50 m and depositing where directed at a level not exc 1.5m above the starting point in soils complete.
M&L search light in watch cabin, high intensity, long range, weather& dust proof security search light with highly polished stainless steel reflector-cum- body suitable heat sinks, toughened front glass retaining ring, MS cradle with passivated bolts. The search light would be supplied with 230V 150 watts LED COB lamp & electronic driver in aluminum housing, the search light would be swivel type & have both vertical & horizontal operational controls with tripod stand with castrol wheel for easy movement inside the tower cabin .
M&L for FR PVC round sheathed copper cable conductor flexible industrail cable 2.5 sqmm ,3 core,1100 Volts, IS 694 cable all required furels/thimbles,copper bolts,nuts, washers as site requirement complete all as specified and directed by Engr-in-charge.
Relocation street light poles, disconnecting cable, removing the light fitting, clamps,safely for reuse with excavation up to 1.5 mtrs,breaking of old PCC, removing the poles by using crane, errecting street light pole as per site location directed, with excavation up to 1.5 meter with PCC 1:4:8 with 40mm graded aggregate for foundation of pole & PCC, 1:3:6, type C-1, with 20 mm graded aggregate for coping of poles up to existing pole height . after completion of work refitting of light,bracket with new bolt, nuts, washers as required at site connecting all electrical cable/wire/terminal box, testing for serviceablity of fitting including removing of excavated materail from the site as directed by Engineer - In - Charge.
M&L for MCCB 4 Pole 32 Amps 25 KA 415 volt with Adjustable thermal & Adjustable magnetic,short circuit breaking capacity Ics = 100% Icu at 415V, in existing panel/enclouser with all fittings and fixtures complete all as specified and directed by Engr - In - Charge
Supply and fixing MCB DB SPN 8 way 240 Volt double type double door with 200 Amps bus bar incomer fixed to wall concealed /surface mounted including connecting up commission complete all as directed.
Supply & fixing 240 V 10 KA 'C' - curve MCB SPN poles and current carrying capacity 32 Amps in DB complete with connection testing and commissioning complete all as directed.
Supply & fixing 240 V 10 KA 'C' - curve MCB of following poles and current carrying capacity SP 5 to 32 Amps in DB complete with connection testing and commissioning complete all as directed.
M&L for XLPE insulated screened PVC bedded galvanised steel strip or wire armored,electric power cable (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 Sqmm 3.5 core connected with suitable lugs.
S & L sub class B burnt bricks for cable protection complete as specified as directed.
Point wiring complete with 2.5 sqmm single core PVC insulated unsheathed cable 1100 volt grade multistranded with copper conductor conforming to IS 694, drawn through and including non metallic rigid PVC conduit ,PVC conduit fitting conduit accessories surface type/concealed run on walls/floors/ceiling including metal flush box of suitable size for modular type fittings surface mounted/concealed on walls with top cover ,switch socket outlets fan regulator etc including 2.5 sqmm PVC insulated single core multi stranded copper conductor cable as earth continuity conductor and connecting to common earth dolly all as specified.
M&L modular switch socket combination 2 in1 3 pin 5 Amps and 15 Amps concealed with Metal box.
Supply and fix sheet metal enclouser Single pole and neutral enclouser with a two pin and earth plug and socket complete with one single pole MCB 10 Amps.
Taking down carefully copper / aluminium sub main wiring including teak wood batten / conduit and making good the disturbed surface of walls as directed.
Taking down carefully copper/aluminium point wiring of any type of batten or conduit (Light, Fan, Socket or power) complete removing material from site and making good the disturbed surfaces of walls, roofs etc including two coats of white/colour washing/distempering etc to match the existing complete all as directed.
M & L point wiring with 1.5 sqmm nominal cross sectional area, single core, 1100 Volts FRLS grade, stranded, PVC insulated, unsheathed copper conductor cable drawn through PVC concealed conduit of suitable size, complete with all PVC conduit accessories/ fittings, brass screws, washers etc, including metal flux boxes of suitable size and modular white plate with frame for mounting modular switches, sockets and regulators etc, including all cutting/chases etc in walls and including continuous earth wire of size 1.5 Sqmm nominal cross sectional area, single core, PVC insulated copper conductor cable, unsheathed and connected to common earth and earth dolly complete all as specified and directed for One light point /Fan point controlled by one switch.
All as per item No 85 above but One 5 Amps socket point on independent board.
Supply & fixing modular switch 06 Amps 1 module complete all as specified & directed.
S & F modular socket 06 Amps 2/3 pin, 2 module complete all as specified & directed.
Supply & fixing modular switch 16 Amps 1 module complete all as specified & directed
S & F modular socket 06/16 Amps 2/3 pin 2 module complete all as specified & directed.
Supply and fixing 35/36 W LED Fitting, 2 x 2 recess / Surface LED flat panel with high brightness LED for glare free homogenous illumination including LED driver complete all as specified. (Make : Havells / CG / Bajaj)
Supply and fixing wall fan of single phase 230/240V of size 400 mm sweep and grouting with nut , bolts & Fastenar on the wall and make good the disturbed surface and electric connection with 1.5 Sqmm three core PVC insulated round flexible copper conductor and sheathed cable complete all as specified and directed.
M & L for sub main wiring complete with two runs of 4 x 4 Sqmm single core FRLS grade PVC insulated unsheathed cable 1100Volt grade multistranded copper conductor drawn through and including PVC conduit and accessories in surface of wall, roofs etc with one run of PVC insulated copper conductor 1x 4 Sqmm single core as earth continuity conductor connected with earth dolly and mains complete all as specified and directed.
M & L for sub main wiring complete with two runs of 2 x 2.5 sqmm FRLS grade PVC insulated unsheathed cable 1100Volt grade multistranded copper conductor drawn through and including PVC conduit and accessories in recessed / surface of wall, roofs etc with one run of PVC insulated copper conductor 1x1.5 Sqmm single core as earth continuity conductor connected with earth dolly and mains complete all as specified and directed.
S & F MCB SPN 32 Amps, 'C' series, 240 V complete incl making conections all as specified and directed.
S & F MCB SP 6-32 Amps, 'C' series, 240 V complete incl making conections all as specified and directed.
S & F MCB DB TPN 4Way, Double Door flush to wall including all cutting etc on wall including making good the disturbed surfaces to match the existing in replacement of old U/s complete all as specified and directed.
S & F MCCB DB Vertical TPN 8 Way 'A' Frame,Including MCCB TPN 100 Amp Beaking capacity 25Ka -01 nos, Double Door flush to wall including all cutting etc on wall including making good the disturbed surfaces to match complete all as specified and directed. Make -Havells or equivalent
S & F MCB TPN 40/63 Amps incl making connections all as specified and directed. Make - Havells or equivalent. Make : Havells or equivalent.
S & F SPD for 3 Phase of cap Type 3P+N, 4 module 12.5kA complete all as specified and directed.
Supply, laying riddled earth soil conformed IS-1255, cushioning to cables with a layer of riddle earth soil 15cm deep before laying the cable and 8 cm depth after laying of cable, complete all as specified.
M & L for G.I. tubing light grade of size 80 mm bore for protection of cables to be laid under roads, crossings/culverts complete all as specified and directed.
Taking up underground unservicable cable of any size from existing trench including bricks, etc and removing of materials from work site all as directed by Engr-in-charge.
Supply, laying, jointing & testing LT electric power under ground cables in trenches or passing through pipe 1100 volts grade, heavy duty with copper conductor of cross sectional area 25 sqmm 4 core with all fixing & connecting accessories such as copper cable lugs, cable gland, nut, bolts, washer etc complete as specified and as directed. Make: Havells/ Polycab/Grandlay/ Universal
All as per Srl item No 104 here in above but size of cable 10 Sqmm 2 core
Laying only cable any sizes obtained from item No 103 of Sch ‘A’ with all fixing & connecting accessories such as Aluminium cable/ copper cable lugs, cable gland, nut, bolts, washer etc complete as specified and as directed
Supply and fix frequency converter of capacity 20 KVA input 3 phase and neutral 415V, 50Hz. output 3 phase 210V, 400Hz, 1 phase 115V, 400 Hz including SMF batteries to provide 30 min backup along with battery stand and interconnecting cables with overload capacity 110% for 10 minutes audio alarm inverter trip, LCD display, indications on for main and inverter with IP 42 enclosure of suitable size, over heating temp 0 to 40 degree and forced air cooling, 75db noise level IGBT based topology including SMF batteries with battery stand and interconnecting cables complete all as specified and directed. Make- APLAB/POWER ONE/SERVO
Taking down earth plug socket / industrial socket of any type and capacity and refixing the same at existing site after civ works complete all as specified and directed by Engr-in-Charge.
Relocation of AC/ DC Panel, and rerouting of existing power supply points, UPS/ commercial supply with 20 nos power socket/DBs with required size of casing capping with all fitting and fixtures. & making existing removed place neat & good condition, Shifting of two Nos DC panel in SDR Lab with out any damage to panel (damages of panel/ meters to be rectified/replace of same specification of damaged items to be replace by the contractor with in the quoted cost) including demolishing the existing PCC removing the panel from its existing place,including diconnecting the cables with line diagram /identification marks to relocation points, shifting the DC panel with required PCC footing 1:2:3 to the required place as per user place in SDR Lab with connecting incomming cables and out going cables to suit the existing wiring diagram with required furrels/thimbles/ bolts.nuts/washers as per site requirement (Note:- after completion of work, conformation and testing the supply of the each point from users.
Aavani BUILDERS AND CONTRACTORS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .