Loading…
Loading…
Tender Value
₹4.0 L
EMD Value
₹12,500
Closing Date
25 Jun 2026, 9:59 pm4d left
Similar tender results from the same govt authority in the past 3 years.
Directorate of Municipal Administration
Shifting of 100kva transformer near konark apartment of ward 46 of hubballi division.
307392
DMA/2025-26/EL/WORK_INDENT54262/CALL-4
Open
Electrical
DMA City Corporation Hubballi-Dharawada
6 documents required · 6 mandatory
₹500
₹12,500
17 Jun 2026
17 Jun 2026
24 Jun 2026
Shifting of 100kva transformer near konark apartment of ward 46 of hubballi division.
Spun Pole Pre-Stressed Tubular Spun Pole - 11 Mtr Long, 500 Kg WL (Dwg No. BESCOM/GM/QS&S/45 Dtd 24.11.2018) as per IS-13158: 1991
Erection Of Spun Pole Erection of 11 Mtr long Concrete Spun Pole in a pit of 2.5 Mtr depth (Mechnised Labour)
Fixing Three H Frame For Three H Frame without Transformer Seating and Seating angle support cross arm for 11 Mtr Spun Pole up to and including 250 kVA (UG Cable) (excluding erection of Pole)
Fixing Three H Frame For Three H Frame without Transformer Seating and Seating angle support cross arm for 11 Mtr Spun Pole up to and including 250 kVA (UG Cable) (excluding erection of Pole)
Fixing of HT/LT Single Top Support
Digging of Pit 2.5 Mtr depth for erection of 11 Mtr long Tubular Spun Pole as per approved Drawing
11 kV, 5 kN Composite/Polymeric Pin Insulator (24 mm dia FRP Rod)
Transparent Alkathine tube 19 mm dia, 2 mm thick in coils of 30 Mtr
For 11 M Spun Pole (1000x1000x150 mm)
B) Pole concreting For 11 M Spun Pole (1000x1000x2500 mm)
Coping for Poles 390 mm all around the pole for an height of 300 mm for Spun Pole(1130x1130x300 mm)
7/10 SWG GI Wire
(7/3.251 mm Dia), Std Wt: 680 Kg/KM
(3.251 mm Dia), Std Wt: 82 Kg/KM
GI Pipe Providing, Laying and Fixing of GI pipes conforming to IS 1239:1990 with latest amendments complete with GI fittings (excluding the cost of fittings) with cuts and threads wherever necessary, ...
Laying the GI Pipe 80 mm to 150 mm dia at Drainage Water Supply Crossing including fixing collars elbows, bends, Tees and other fitting with Cuts and Threads wherever necessary
Rod type of earthing using 40mm dia 3 mtr long M.S rod as ground rod,in earth pit of 300mm width and 3300mm depth and using 50X6 mm flat welded to ground rod as terminal is connected to equipment grou...
Fixing Caution/Danger Board
Anticlimbing Device GI Barbed wire (12 Mtr/Kg)
Horizontal Cross Arm 11 kV, Horizontal Cross Arm - Mild Steel (MS)
(Dwg No. BESCOM/GM/QS&S/04 Dtd
Fixing Horizontal Cross Arm cross arm with Insulator and Braces fixing
Fixing DOLO Cutout/Horn Gap Fuse including fixing of cross arm and wiring
GOS 11 kV, 200 Amps Single Break GOS
fixing GOS Fixing of GOS including wiring (11 kV Single Break 200 Amps)
Rabbit ACSR Conductor
(6/3.35 mm Al + 1/3.35 mm St), Std Wt: 214 Kg/KM
Stringing of Conductor do - for Rabbit ACSR
Fixing LT Distribution box for 100/250/500 kVA DTC (Excluding wiring)
PVC Wire - 240 Sqmm
Al Wt: 63.5 Kg, Total Wt: 87 Kg/100 Mtr Coil
Heavy Duty Copper Terminal Long Barrel 240 Sqmm Copper Terminal, Apprx Wt: 218 Gm
PG Clamp Rabbit to Insulated Wire 240 Sqmm
LT Line Spacer For TC Wiring
11 kV Lightning Arrester, Metal oxide,10 kV, 5 kA Polymeric Type with ground disconnector
11 kV, 3 Core, XPLE HTUG Cable with
pressure extruded inner sheeth, ROUND
WIRE ARMOURED as per IS-7098 (Part-2)
Armouring wires dia and Resistivity as per IS-3975 95 Sqmm, (54 GI Wires - 2.5 mm Dia...
Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 3x95 to 150 Sqmm
Heat Shrinkable Straight Through Jointing Kit for
XLPE Cable with Copper Lug & Al Ferrule 3x95 Sqmm
HT UG Cable Heat shrinkable Straight Through Joint3x95 to 3x150 Sqmm
In all kinds of soils Depth upto 1.50 m Earth work excavation for pipelines/cables by Manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shoring...
Refilling available earth around trenches/pipelines,
cables in layers not exceeding 20 cm in depth,
compacting each deposited layer by ramming after
watering with a lead upto 50 m , and lift upto 1.5
Dismanting of Steel/I- Beam 90% of the Pole erection charges
Fixing of LT Protection Kit
Releasing GOS Fixing of GOS including wiring (11 kV Single Break 200 Amps)
Releasing DOLO Cutout/Horn Gap Fuse including fixing of cross arm and wiring
Releasing Wiring of 1 Circuit of LT Wiring for for 25/63/100 kVA DTC to the existing LT protection Kit/ Distribution Box via metering box. (includes fixing of necessary supports like 2 Pin cross arm, ...
Releasing 9 Mtrs RCC Transformer Structure DP 100 KVA
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.