| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.9 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹12.7 L+₹3.4 L (37.0%)Rejected-AOC | L2 | Rejected-AOC Not Lowest Bidder | |
| 3 | L3₹12.9 L+₹3.6 L (39.0%)Rejected-AOC 37 222 BUNDU KATRA AGRA UP | AGRA | UP | L3 | Rejected-AOC Not Lowest Bidder | |
| 4 | L4₹13.6 L+₹4.3 L (46.6%)Rejected-AOC | L4 | Rejected-AOC Not Lowest Bidder | |
| 5 | L5₹14.1 L+₹4.8 L (52.3%)Rejected-AOC | L5 | Rejected-AOC Not Lowest Bidder |
Tender Value
Refer Docs
EMD Value
₹30,000
Closing Date
10 Oct 2020, 6:00 pmClosed
GE Bharatpur
GE Bharatpur
REPAIR/MAINTENANCE OF SECURITY/STREET LIGHTING SYSTEM, CABLING AND CONNECTED ITEMS AT DEPOT AREA UNDER GE BHARATPUR
2020_MES_377348_1
8974/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
GE Bharatpur
Class E category b (i)
7 documents required · 7 mandatory
₹500
Yes
GE Bharatpur
₹30,000
Yes
19 Oct 2020
14 Sept 2020
12 Oct 2020
14 Sept 2020
10 Oct 2020
27 Sept 2020
Amount
Dismantling and taking down non functional/ unserviceable /energy inefficient street /security light fittings of capacity 70/150/250/400W existing complete all as specified and directed by Engineer-in-Charge.
Dismantling /taking out old unused damage PCC pole and removing from site a distance n. Exc 100 Mtr including Excavation and returning filling complete
Dismantling old U/S GI bracket of any size & length complete all as specified and as directed by Engineer-in-Charge.
Taking out old un-servicable/ faulty PVC armoured LT under ground cable of any size any core complete all as specified and as directed by Engineer-in-Charge.
S&F or laying ross linked poly-ethylene (XLPE) insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables ( heavy duty) with aluminium conductor, 1100 volts grade of cross-sectional area 16 Sqmm 04 core laid in trenches/through pipe in road crossings/ paths /drains /ducts /floors /along poles/walls/ceilings/ equipments etc including commissioning and testing complete all as specified and as directed by Engineer-in-Charge.(Note: :- (i) Necessary excavation and earth work, brick protection, sand cushioning and cover and GI pipe shall be measured and paid for separately.)
Dismantling and taking down existing street/security LED light fittings of capacity 45w/ 60w/90w/ 120w for repair/ replacement of burnt/worn out assy/ surge protector and refixing the same after repair/replacement complete all as directed by Engineer-in-charge. Note: Repair work will be measured & paid separately
M & L of LED surge protector 10 KV multiple type 2 surge arrestors with thermal monitaring device and connector,dual visual fault indicator for the discharge path of the supply voltage and control the phase. Note: Repair work will be measured & paid separately Make: CG cat pt No SRPS-HP-5K-320 or equivalent suitable make of phillpis/Bajaj or Surya/Havells
M & L of LED drivers rated voltage 12/24 volt maximum out put power 75 W typical efficincy 93% of make. CG cat pt No DRVP-75w/700 (Coad No: X075C070V107FNY1BO) or equivalent suitable make of phillpis/Bajaj or Surya Note: Repair work will be measured & paid separately
M & L of LED drivers rated voltage 12/24 volt max out put power 100 W typical efficincy 93% of make CG cat pt No DRVP-100w/700 (Coad No: X100C070V107FNY1BO) or equivalent suitable make of phillpis/Bajaj or Surya Note: Repair work will be measured & paid separately
M&L for PCC (1:3:6) type C1 using 20mm grade stone aggregate in subbase of pole foundation including necessary form work complete all as specified.
M&L for PCC 1:2:4 type B1 using 20mm graded stone aggregate in coping of existing/new poles / foundation for poles, struts, posts etc including necessary form work, finished the exposed surfaces fair and even without using extra cement complete all as specified and directed.
S & F street light GI bracket of 1.2 mtr long made out of 40mm dia light grade GI pipe bend to shape of 120 degree end welded at required including 02 Nos MS clamp of flat iron 40 x 6mm including nuts bolts & washers complete necessary fixing arrangements on pole as directed.
S & F in replacement cable copper multi stranded of size 1.5 SQm 3 core from over head ACSR conductor to fitting complete all as directed by Engineer-in-charge. Make Paragone ,finolex , Gloster
Excavation in trenches in soft/loose soil not exceeding 1.5m wide and not exceeding 1.5 metre in depth and getting out for laying of cable etc. complete all as specified and as directed by Engineer-in-Charge. (Taking out old brick from trenches shall be measured separately and deduction for brick shall be made on this account).
Returning, filling in soft/loose soil including spreading, levelling, watering and well ramming, in layers not exc 25 cm complete all as specified and as directed by Engineer-in-Charge.
Removing of surplus soil to a distance not exc. 50 metre and depositing where directed at a level not exc.1.5 metre above the starting point complete all as specified and as directed by Engineer-in-Charge.
M&L Protection to cable with one layer of bricks laid flat abutting to each other in such a way that the length of the bricks is at right angle to the central axis of the cable using old size sub-class ‘B’ burnt-clay bricks, complete all as specified and as directed by Engineer-in-Charge. (Note: the gap between two adjustable bricks should not be exceed 10 mm )
M&L Un washed machine sand as cushioning of under ground cable (8 cm thick layer of sand before laying of cable and 15 cm thick layer of sand after laying of cable) and punned after laying complete all as specified and as directed by Engineer-in-Charge. Note: Only punned thickness will be measured
S & F or laying galvanised steel tubing medium grade (ISI marked) for protection of under ground cable on poles/walls under road crossing of size 40mm bore complete all as specified and as directed by Engineer-in-Charge.
Supplied and fixed in repair Pin type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 100 mm height, 65 mm dia. for working pressure 1100 volts grade, complete all as specified and as directed by Engineer-in-Charge. Make : Bengal potteries/ Jay Sree/Bikaner
S&F in repair for shackle type, vitreous, white, brown, or green insulators, including galvanised mild steel strips, washers, insulators bolts, washers and nut for working pressure 1100 Volt, 100mm height 115mm dia, glavanised steel fitting strips of size 21 x 5mm, 14mm dia bolts complete all as specified and as directed by Engineer-in-Charge. Make : Bengal potteries/ Jay Sree/Bikaner ceramics/ Mysore.
Trimming/prunning and removing of tree branches or any other forein objects from HT/LT over head conductor and clearing the OH Line of any type and size for one span of any length in 2 way /4 way/6 way conductor system complete all as specified and as directed by Engineer-in-Charge. Notes: (i) Insulators of any type, connectors and ACSR conductor of any size required at site will be measured and paid separately under relevant item of this schedule. (ii) The contractor is responsible for provision of Necessary T & P and safety equipments to complete the job. (iii) Quoted rate is deemed to inclusive of Replacement of Insulators, Joining the ACSR Conductor, Jumpering and stringing the ACSR conductor etc.
Supplying, errecting and fixing steel tubular swaged poles with cast iron base plate of size 300mm x 300mm x 6mm, finial taper plug, bolts, nuts & screws for type 410 SP-31 (9.0 metres long) including painting with two coats of aluminium paint over one coat of redoxide primer on all exposed surfaces and tarring with black bituminous paints to embedded portion in PCC and providing 3 Nos of 30cm wide circular bands with black & yellow paint starting from plinth level at a gap of 30 cm in between 2 bands and numbering of poles, in yellow paint over black painted back ground at a height of 2m from bottom of pole with 5 cm large bold letters 2" (inch) wide complete all as specified and directed. Note: Excavation, earth work, PCC in foundation and coping shall be measured and paid separately under relevant item of this schedule.
Supply, install, test and commissioning factory made THERMOPLASTIC CABLE JUNCTION BOXES IP 66/67 “weather proof”, with terminals for outdoor installation (with knockouts for cable entry) of size 205 x 255 x 112 mm depth with cable entry size of 10-25 sqmm with 4 pole terminal capacity 100A each (all terminal have 02 clamping unit per pole) , glands including with flat iron clamps of size 30 x 6mm, nuts and bolts. Make Hansel Cat part No:KF 2525 G or equivalent make in /FIBOX(SOLID PC 2528 13G)
S&F new generation energy saving and environmental friendly long life varsatile pressure die cast aluminium IP66 road way light fitting with high power LED as light source of capacity 60 watts with suitable drivers and included 10KV SPD etc and connecting with 4.0 sqmm aluminium conductor PVC insulated twin core weather proof cable etc, fixing to wall / pole with and including bracket made out of GI pipe of suitable dia light grade not less than 1.5 mtr long, bent to shape, fixed to Pole/Wall in any position with flat iron clamps of size 30 x 6mm including taking down old unserviceable street light fitting of any type and capacity complete all as specified and directed. Make:- Crompton Cat Part NoLSTP-60-CDL-Mor equivalent model of Philips/Bajaj/Havells.
All as per item No 26 here-in-before but90 watt LED fittings. Make:- Crompton Cat Part No LSTP-90-CDL-M or equivalent model of Philips/Bajaj/Havells.
All as per Srl item No 26 but LED flood light fittings 150 watts 230 volt complete and all assy duly prewired and pressure die cast aluminium housing,heat resistant tough glass with frame,IP 66 protection and included 10KV SPD ans better optic for uniform distribution. Make:- Crompton Cat Part No LFLN-150-CDL/60-M or equivalent model of Philips/Bajaj/Havells
S&F in replacement MCCB 04 pole 100 Amp, DPX3 160 Thermal maganatic, breaking capacity not less than 16 KA,415 volts complete all as specified and as directed by Engineer-in-Charge. (Cat Part No 420055 in Legrand or equivalent makes mentioned in Appex D)
S&F in replacement MCCB 04 pole 125 Amp, DPX3 160 Thermal maganatic, breaking capacity not less than 16 KA,415 volts complete all as specified and as directed by Engineer-in-Charge. (Make in Legrand or equivalent makes mentioned in Appex D)
M&L earthing complete with galvanised steel earth plate electrode 60x60cmx6mm thick, burried directly in ground (earth pit not less than 2.25 meters deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level connected to galvanised iron steel 4 mm dia by means of bolts, nuts check nuts and washers of galvanised iron or steel all as showin in electrical plate No 3 connected to earthing test point all as specified or indicated includig testing on completion.
M & L Cross arms bracings supports clamp and back plate fabricated from structral steel section including nuts bolts washers welding bending cold or hot drilling holes for bolts in any shape or size as indicated or directed and including one coat of red oxide zinc chrome primer and final finished with one coat of synthetic enamel paint complete all as specified and directed by Engineer-in-Charge.
Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine for laying under ground pipe up 100mm dia complete Note :- GI pipe shall be measured and paid in concern Item
M&L of painting of pole intially with single coats of primer paint on exposed surfaces after scraping old deterirorated paint and after that providing 3 Nos of 30cm wide circular bands with black & yellow paint starting from plinth level at a gap of 30 cm in between 2 bands and numbering of poles, in yellow paint over black painted back ground at a height of 2m from bottom of pole with 5 cm large bold letters 2" (inch) wide.
Attending day to day complaints of street lights, replacing burnt out wires, reconnection of loose terminals, securing the clamps, jumpers etc all as specified and as directed by Engineer-in-Charge. Note: Contractor shall provide suitable techcian including all kind of climbing and safety materials along with tools. Rates including taking down, repairing and reconnecting as per existing position. Note :(a) All T & P/Bamboo ladder and labour team required comprising of Nos of trained electricians & helpers will be provided by the contractor based on complaint as directed.(b) Rep of the contractor will present in complaint cell & responsible for receiving & attending the complaints from 0900 Hrs to 1700 Hrs at the time of lodging the complaint. In absence of rep of Contractor penal recovery as decided by GE shall be imposed & on contractor.(c) Cost of minor stores such as screws,clamps,insulation tapes,nuts/bolts, nail of required size etc shall be deemed included in the above quoted rate. However, major items such as switches, sockets, bell push, fan regulator, air conditioning condensers and sensors etc shall be measured and paid separately under appropriate items of Schedule 'A'.(d) Complaints where complete replacement of circuit/point wiring required shall be measured under relevent item.(e) If contractor fails to rectify the complaint with in 24 hours after receiving, Rs 500/- per complaint will be penalised.
Supplying and stringing Aluminium conductor, steel reinforced (ACSR) any type of ACSR conductor as per site requirement of size /make as ordered including stringing for overhead line on LT poles including aluminum binding wire 14 SWG, jumpers, line tapes, conducting jelly etc including taking down of existing aluminium conductor complete all as specified and as directed by Engineer-in-Charge. (Notes : (i) The ACSR conductors shall be conforming to IS-398 and as specified in SSR Part-I.(ii) The unit rate quoted shall also be deemed to include for supply & fixing of aluminium binding wire, aluminium tapes etc which shall not be included in the weight of conductors.(iii) Weight of conductors shall be determined by measuring true horizontal distance between centers of two adjacent poles and compounding the weight of conductors of that size and length and 3% extra added for sag, jointing, jumpers etc. (iv) Weight of the conductors shall be calculated from the nominal weights given in tables in the relevant IS.)
krishna Associate
PD GUPTA AND COMPANY
M/s Ranaji Construction Co
S D POWER SOL
Pioneer Enterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .