| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.7 LAccepted-AOC | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹34.3 L+₹1.6 L (4.81%)Rejected-Finance KHAWASNIWAS NEAR POLICE QTRDEORALI GANGTOK SIKKIM | L2 | Rejected-Finance Not being lowest | |
| 3 | L3₹35.3 L+₹2.7 L (8.13%)Rejected-Finance | L3 | Rejected-Finance Not being lowest | |
| 4 | L4₹35.7 L+₹3.0 L (9.24%)Rejected-Finance | L4 | Rejected-Finance Not being lowest | |
| 5 | L5₹36.0 L+₹3.3 L (10.1%)Rejected-Finance 27 ABUSETH ROAD DEHU ROAD PUNE 412 101 | NA | NA | 412101 | L5 | Rejected-Finance Not being lowest |
Tender Value
₹30.9 L
EMD Value
₹62,000
Closing Date
23 Jul 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Gangtok
GE Gangtok New Mil Stn Gangtok, Sikkim PIN-737102
PROVN OF CERTAIN SANCTIONED WORKS AT NEW MILITARY STATION GANGTOK
2021_MES_456567_1
8976
Open Tender
Miscellaneous Works
Item Rate
182 days
Gangtok
As per tender documents
8 documents required · 8 mandatory
₹500
GE Gangtok
₹62,000
Yes
18 Aug 2021
2 Jul 2021
26 Jul 2021
2 Jul 2021
23 Jul 2021
12 Jul 2021
60 days
Amount
Excavation in post holes (or similar holes) in soft/loose soil each n.exc 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers n.exc 25 cm and removing surplus soil to a distance n.exc 50 mtrs complete all as specified and directed by the Engr-in-Charge
Surface dressing n.exc 30 cm deep and averaging 15 cm deep and getting out in soft/loose soil complete all as specified and as directed.
Excavation in trenches in soft/loose soil not exc. 1.5 metre wide and not exc. 1.5 metre in depth and getting out complete all as specified and as directed by the Engr-in-Charge.
M&L for PCC 1:4:8 , type D-2 (using 40 mm graded crushed stone aggregate) as in foundation, filling and mass concrete complete all as specified and as directed.
Returning, filling in, including spreading levelling watering and well ramming in layers not exceeding 25 cms in depth in soft/loose soils complete all as specified and as directed by the Engr-in-Charge.
Removing excavated material to a distance n.exceeding 50m and depositing where directed at a level not exc. 1.5 mtr above the starting point complete all as directed by the Engr-in-Charge.
M & L for hard core of gauge not exc.63mm,deposited,spread and leveled in layers not exc.15cm thick,watered and rammed to a true surface using broken stone boulders complete all as specified and as directed.
M&L for 100mm thick cement concrete 1:3:6 type C-2 (using 40mm graded stone aagregate) as in hardstanding/flooring and finishing the surface even and fair etc complete all as specified and directed.
M&L for 25mm thick PCC(1:2:4), type B1 (using 20mm graded stone aggregate), finished concrete surfaces even and rough to receive floor finishes complete all as specified and directed..
M&L for non skid ceramic coloured tiles 7mm to 8mm thick (square/rectangular) area of each tile exceeding 0.11 Sqm, but not exceeding 0.18 Sqm, in floors etc conforming to IS-13712 grade B-II-(a) over and including 15mm thick screed in CM 1:6 etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the shades of tiles complete all as specified & as directed.
S&F rolled section as in main and cross beams, hip and jack rafters, purlins where connected to common rafter and running rails and guides for sliding doors fixed with angle clear or other connecting plates conforing to Fe-410-W(Gde-E-250 quality-A)including one coat of red oxide zinc chrome primer after preparation of surfaces at contractor''s workshop before fabrication complete all as specified and as directed.
S&F 0.50mm thick pre-painted galvalume aluminium zinc silicon finished with resin coat on both side @ 70 grms/Sqm GI based corrugated steel sheets of any colour and any pattern as approved having tensile strength of 550 Mpa as in roof covering fixed with self tapping screws as in roof complete all as specified and as directed.
S&F 0.50mm thick pre-painted galvalume aluminium zinc silicon finished with resin coat on both side @ 70 grms/Sqm GI based corrugated steel sheets of any colour and any pattern as approved having tensile strength of 550 Mpa as in ridges, valley, eaves etc fixed with self tapping screws complete all as specified and as directed.
M&L for applying two coats of synthetic enamel paint over a coat of red oxide primer to new or previously un-treated steel surfaces of any description over 10cm in width or girth including preparation of nw steel surfaces complete all as specified and as directed.
Material and labour for PCC (1:3:6) type C-2 using 40mm graded stone aggregate as in surface channels and drains complete all as specified and as directed.
S&F for PVC(SWR) half round 150mm bore with round edges incl all accessories like bend 'T' etc complete all as specified and directed.
Supply and fix PVC (SWR) pipes 110mm bore, single socketed, in any length with rubber ring joints fixed to wall/trenches complete all as specified and directed by the Engr-in-Charge.
Supply and fix 110 mm bore PVC (SWR) bends any radius complete all as specified and directed by the Engr-in-Charge.
Supply and fix 110 mm bore PVC (SWR) equal or unequal junction single (Single T) complete all as specified and directed by the Engr-in-Charge.
M&L for rendering 15mm thick in cement mortar (1:6) in two layer of 10mm thick each with using on other than fair face of brick/stone masonry (external surfaces) finished surface fair and even without using extra cement complete all as specified and as directed.
Material and labour for walling of random rubble, uncoursed, well bonded, bedded and solidly hearted, built in cement mortar (1:6) including brought upto course complete all as specified and as directed by the Engr-in-Charge.
Material and labour for PCC 1:3:6 type C-1 (using 20mm graded stone aggregate) as in coping including weathering slightly rounded or chamfered angles and throating complete all as specified and as directed by the Engr-in-Charge.
M&L for lacquer coated chequered cement concrete tiles 20cm x 20cm x 25mm/ 30cm x 30cm x 25mm thick, set jointed and pointed in neat cement slurry in floors with grey cement and pigments over and incl 15mm thick screed bed or bedding layer of in CM 1:6 all as specified.
M&L for Brickwork with subclass ‘B’ bricks, straight or curved on plan to any radius in half brick thick walls, built in complete all as specified and as directed.
E/M Part
Supply, laying, jointing and testing in trenches or passing through pipe, 1100 Volts grade XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured LT electric power under ground cable conforming to IS:7098 (Pt-I)-1988, heavy duty with aluminium conductor of cross sectional area 95 Sqmm 3.5 core with necessary fixing arrangements such as lugs, glands and terminal etc complete all as specified and as directed including taking down old U/s one
All as per Srl item No 26.00 here-in- before but for 50 Sqmm 3.5 Core complete all as specified and as directed including taking down old U/s one.
All as per Srl item No 26.00 here-in- before but for 16 Sqmm 2 Core complete all as specified and as directed including taking down old U/s one.
All as per Srl item No 26.00 here-in- before but for 10 Sqmm 2 Core complete all as specified and as directed including taking down old U/s one.
Excavation in trenches n. exc 1.5 mtr wide and n. exc 1.5 mtr in depth for laying of cable and getting out in hard /dense soil complete all as directed.
Supply and laying DWC pipe SN-4 with coupler 50 mm OD,ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. laid in trenches/ fixed to pole /laying under road crossing/fixed on pavement walls with clamps complete all as specified and as directed.
Supply and laying DWC pipe SN-8 with coupler 75 mm OD,ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. laid in trenches/ fixed to pole /laying under road crossing/fixed on pavement walls with clamps complete all as specified and as directed.
Supply and laying 80 mm bore GI pipe light grade including fittings fixed to pole/laying under road crossing with clamps complete all as specified and as directed
M & L for Plain cement concrete (1:3:6) type C-1 using 20 mm graded stone aggregates as finishing road/concrete surface including finishing to exposed concrete surfaces even and fair complete all as specified.
Supply and fix in repair, Street light cable junction box made of polycarbonate, ''halogen free and weather proof', for outdoor installation (with metric knockouts for cable entry) IP-66 protection including short cable entry gland tread type with lock nut, four way bakelite terminal with brass studs and nuts, GI flat strip clamps of size 25mm X 3mm with bolts, nuts and washers for fixing with MCB one 06 Amps inside the junction box complete all as specified & as directed. (Make: HENSEL Cat No. KF-1616 or equivalent approved make.
Supply & fixing 1.5 Sq.mm 3 core, 240volts Copper Conductor cable heavy duty PVC insulated, round sheathed ISI marked in PVC conduit all as specified and directed by Engr In charge
M & L for earthing in repairs complete with galvanized steel earth plate electrode 600x600x6 mm thick, burried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less 1.5 mtr deep below normal ground level connected to GI earth wire 4 mm dia connected to earth plate by means of nut, bolts, check nut & washer of galvanized iron or of steel, GI earth wire will be protected by 15 mm dia GI pipe 'light grade', watering pipe 20 mm dia GI 'light grade', GI wire meshed funnel, alternate layer of char coal and salt on all side to earth plate upto thickness of 150 mm, filling of black cotton soil in earth pit upto ground level, PCC chamber recessed for and including RCC cover including all necessary excavation & earth work, earth wire connected to O/H continious earth wire on pole, testing the earthing after completion all as specified and shown in electric plate No 3 of MES SSR Part-I 1991 print and as directed .
M & L for flame proof point wiring for light complete with stranded copper conductor of 1.5 Sqmm PVC insulated, unsheathed FRLS (electron beam cross linked (EXBL) flame proof building wire 1100 volts grade, confirming to IS 694, multi stranded, drawn through and including stove enameled conduit confirming to IS-9357, including flame proof accessories, fittings and junction box along with 1.5 sqmm PVC insulated copper conductor continues earth wire one light point controlled by one flame proof rotary switch complete all as specified and directed.
M & L for flame proof point wiring for light complete with stranded copper conductor of 1.5 Sqmm PVC insulated, unsheathed FRLS (electron beam cross linked (EXBL) flame proof building wire 1100 volts grade, confirming to IS 694, multi stranded, drawn through and including stove enameled conduit confirming to IS-9357, including flame proof accessories, fittings and junction box along with 1.5 sqmm PVC insulated copper conductor continues earth wire one additional light point controlled on the same switch circuit complete all as specified and directed.
M & L for flame proof point wiring for one 3 pin socket outlet 15 amps, independent, with stranded copper conductor of 4 Sqmm PVC insulated, unsheathed FRLS (electron beam cross linked (EXBL) flame proof building wire 1100 volts grade, confirming to IS 694, multi stranded, drawn through and including stove enameled conduit confirming to IS-9357, including flame proof accessories, fittings and junction box along with 4 sqmm PVC insulated copper conductor continues earth wire complete all as specified and directed.
S & F switch flame proof rotary type with termination box in LM6, 16A, single pole 250V completeall as specified and directed..
S & F Flame proof switch socket & plug combined in LM6, 16A, 250V, 2P+earth completeall as specified and directed..
Supply & fixing LED light fitting 1 x 8 Watt, flame proof, CMRI certified recommended for gas/vapour proof of IIA & IIIB, zone 1 & 2 and IP 65 protection with die cast aluminium housing with heat resistant toughened glass, with LED tube light fixtures driver, holders, connector etc. complete with all accessories prewired and including connecting up with three core flexible copper conductor cable of suitable size complete all as directed. Make : Crompton Cat No - EXTN1LT8-8 or equivalent approved make.
Supply & fixing LED light fitting 1 x 16 Watt, flame proof, CMRI certified recommended for gas/vapour proof of IIA & IIIB, zone 1 & 2 and IP 65 protection with die cast aluminium housing with heat resistant toughened glass, with LED tube light fixtures driver, holders, connector etc. complete with all accessories prewired and including connecting up with three core flexible copper conductor cable of suitable size complete all as directed. Make : Crompton Cat No - EXTN1LT8-16/20 or equivalent approved make.
Supply & fixing LED light fitting 2 x 16 Watt, flame proof, CMRI certified recommended for gas/vapour proof of IIA & IIIB, zone 1 & 2 and IP 65 protection with die cast aluminium housing with heat resistant toughened glass, with LED tube light fixtures driver, holders, connector etc. complete with all accessories prewired and including connecting up with three core flexible copper conductor cable of suitable size complete all as directed. Make : Crompton Cat No - EXTN2LT8-16/20 or equivalent approved make.
Supply & fixing LED light fitting 60 Watt, flame proof, CMRI certified recommended for gas/vapour proof of IIA & IIIB, zone 1 & 2 and IP 65 protection with die cast aluminium housing with heat resistant toughened glass, with LED light fixtures driver, holders, connector etc. complete with all accessories prewired and including connecting up with three core flexible copper conductor cable of suitable size complete all as directed. Make : Crompton Cat No - FWL1315-60-CDL or equivalent approved make.
Supply & fixing LED light fitting 120 Watt, flame proof, CMRI certified recommended for gas/vapour proof of IIA & IIIB, zone 1 & 2 and IP 65 protection with die cast aluminium housing with heat resistant toughened glass, with LED light fixtures driver, holders, connector etc. complete with all accessories prewired and including connecting up with three core flexible copper conductor cable of suitable size complete all as directed. Make : Crompton Cat No - LHB-120-CDL/60-M or equivalent approved make.
M&L for concealed sub-main wiring along with earth wire of size of 2 x 6.0 sq mm + 1 x 6.0 sq mm earth wire, ISI marked FRLS,PVC insulated, multi stranded, copper conductor, single core cable drawn through and including stove enameled conduit confirming to IS-9357, including flame proof accessories, fittings and junction box along with 6 sqmm PVC insulated copper conductor continues earth wire complete all as specified and directed.
M&L for submain wiring alongwith earth wire of size 2x6.0 Sqmm + 1x6 Sqmm earth wire ISI marked FRLS PVC insulated multi stranded copper conductor single core cable drawn in and incl PVC conduit of adequate size with all accessories as required as specified and as directed incl taking down old unserviceable submain wiring. (Note : Three runs of PVC wire with one run of PVC conduit will be measured and paid as one length.)
S&F Flame proof DB 8 Way with CMRI certified with provn and including following switch gear Incoming (a) Flame proof rotary switch with MCB SPN 40 Amps, 10 kA - 01 No as Incoming. (b) Flame proof rotary switch with MCB SP 10 Amps, 10 kA - 02 Nos, MCB SP 16 Amps, 10 kA - 02 Nos, MCB SP 20 Amps, 10 kA - 02 Nos, as Outgoing complete all as specified and as directed.
Supply, laying, jointing and testing in trenches or passing through pipe, 1100 Volts grade XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured LT electric power under ground cable conforming to IS:7098 (Pt-I)-1988, heavy duty with aluminium conductor of cross sectional area 16 Sqmm 4 core with necessary fixing arrangements such as lungs, glands and terminal etc complete all as specified and as directed.
Supply, laying, jointing and testing in trenches or passing through pipe, 1100 Volts grade XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured LT electric power under ground cable conforming to IS:7098 (Pt-I)-1988, heavy duty with aluminium conductor of cross sectional area 10 Sqmm 2 core with necessary fixing arrangements such as lungs, glands and terminal etc complete all as specified and as directed.
Supply and laying 40 mm bore GI pipe light grade including fittings fixed to pole/laying under road crossing with clamps complete all as specified and as directed
Supply and laying 32 mm bore GI pipe light grade including fittings fixed to pole/laying under road crossing with clamps complete all as specified and as directed
Supply and fix Cable junction box IP 66/67 made of polycarbonate, ''halogen free and weather proof', for outdoor installation (with metric knockouts for cable entry) including short cable entry gland thread type with lock nut, terminals , GI flat strip clamps of suitable size with bolts, nuts and washers or fixed on walls complete all as specified & as directed by Engineer in charge. (Make: HENSEL Cat No. DK-2525G or equivalent approved make.
M & L for point wiring with 1.5 Sqmm PVC insulated unsheathed single core stranded copper conductor (FRLS) Cable of working voltage 1100 Volts grade conforming to IS-694 pt-I & II of 2000 drawn in and including 25 mm size PVC rigid non metallic casing caping (Double lock) with all casing capping fittings & accessories with 1.60 mm thick pressed steel or mild steel sheet sunk box covered with 3 mm thick backelite sheet fixed with brass screws & cup washers including 1.5 sqmm PVC insulated unsheathed single core stranded copper conductor (FRLS) cable as earth continuity conductor connected to main switch / DB's or common earth dolly complete for for light point/ fan point/ exhaust fan point/ call bell point/ controlled by one switch 5/6 Amp one way complete all as specified and directed.
All as per item no. 57 but switch socket combination 3pin 5 amps on independent board
All as per item no.57 here-in-before but for one socket outlet of 15 Amps fixed on independent board with 2.5 Sq mm multistranded copper conductor wire FRLS PVC insulated and 2.5 Sq mm copper conductor wire FRLS PVC insulated using as earth wire complete all as specified and directed by Engineer-in-Charge
S&F switch socket combination, 2 in 1, 6 pin, 5/6 Amps and 15/16 Amps, multipurpose, flush, non shutter, non inter locking type, 230 volt flush type, white/ivory finish with two fixing hole including suitable gang box complete all as specified and as directed.Make : Anchor Cat No38808/50665 or equivalent approved.
S&F in repairs switch socket combination, 2 in 1, 6 pin, 5/6 Amps , multipurpose , flush, non shutter, non inter locking type, 230 volt flush type, white/ivory finish with two fixing hole including suitable gang box complete complete all as directed including taking down old one. Make : Anchor Cat No 38808/50665 or equivalent of approved make
S&F in repairs switch piano, flush type, 6 amps, 230 volts, single pole, one way (ISI marked) complete all as directed by Engineer-in-charge Make : Anchor Product Code No 50053 or equivalent of approved make
S&F in repairs ceiling rose, PVC/polycarbonate insulated body, 3 terminal and 240 volts, ISI marked complete all as specified and directed Make : Anchor Product Code No 39040 or equivalent of approved make
S&F in repairs lamp holder angular/straight insulated body, with back plate suitable for batten fittings, white/ivory finish complete all as directed. Make : Anchor Product Code No 39527 or equivalent of approved make
S&F in repairs LED lights fitting 1x 18W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed (Make : Havells Cat No LUMLINEPLUSBS18WLED865SPCSS or equivalent of approved make)
S&F in repairs sheet metal enclosure DB's 240 Volts, IP-43, suitable for mounting MCB's, SPN, 8 way with 200 Amps rated copper bus bar double door type complete and including taking down old DB with MCB complete all as specified and as directed.vells/ABB/Legrand) (Make : L&T cat No DBSPN008DD or equivalent of approved make)
S&F in repairs MCB single pole & neutral 40 to 63 Amps, 240 Volts, 10 KA rapturing capacity, 'C' Curve complete all as directed by Engineer-in-charge. (Make : L&T cat No BB20400C to BB20630C or equivalent of approved make)
S&F in repairs MCB single pole 6 to 32 Amps, 240 Volts, 10 KA rapturing capacity, 'C' Curve complete all as directed by Engineer-in-charge. (Make : L&T cat No BB10060C to BB10320C or equivalent of approved make)
M/S S. S CHETTRI AND SONS
M/S ANIL KUMAR THAKUR
KAMLESH ENTERPRISE
STAR CONSTRUCTION
DHARMINDER SINGH
KARMA TSETEN BHUTIA
KARMA SHERPA
RAAJ BANGAR
M/S MANOJ VERMA
SANJAY MITTAL
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .