| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹48.6 LAccepted-AOC | L1 | Accepted-AOC DUE TO L1 BIDDER | |
| 2 | L2₹50.7 L+₹1.9 L (3.93%)Rejected-Finance | L2 | Rejected-Finance REJECTED DUE TO L2 BIDDER | |
| 3 | L3₹50.8 L+₹2.0 L (4.19%)Rejected-Finance | L3 | Rejected-Finance REJECTED DUE TO L3 BIDDER | |
| 4 | L4₹51.3 L+₹2.5 L (5.06%)Rejected-Finance | L4 | Rejected-Finance REJECTED DUE TO L4 BIDDER | |
| 5 | L5₹53.5 L+₹4.8 L (9.74%)Rejected-Finance | L5 | Rejected-Finance REJECTED DUE TO L5 BIDDER |
Tender Value
₹47.8 L
EMD Value
₹90,000
Closing Date
24 Feb 2025, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
MOHAN SINGH YADAV, IDSE
GE TENGA PIN-900694 C/O 99 APO
PROVISION OF COVERED DRAINAGE AND SOAKAGE PITS SEPTIC TANK DG PLINTH ALONG WITH OPEN SHED AND SPECIAL REPAIR WORKS AT DIFFERENT POCKETS AREA OF AGE BR AND AGE EM UNDER GE TENGA
2025_MES_695877_1
8704/E8
Open Tender
Civil Works
Item Rate
180 days
GE TENGA
PLS REF TENDER DOCUMENTS
7 documents required · 7 mandatory
₹500
GE TENGA
₹90,000
Yes
29 Mar 2025
31 Jan 2025
25 Feb 2025
31 Jan 2025
24 Feb 2025
14 Feb 2025
Amount
Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for
Demolition of Concrete (unreinforced) of any description and in any position not otherwise specifically provided for cement concrete (for coping) complete all as specified and directed.
Demolition of PCC Block wall masonry,built in cement mortar including all quoins, arches, pillars etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed.
M&L 19- 20 mm thick granite (of any type) work (table rubbed and polished) in cooking platforms in CM 1:4 including pointing in white cement 1:2 using marble dust with admixture of pigment to match with shade of granite all as specified.
Demolition floor, hearth or tiling including cement mortar bedding (but not backing).
M&L for 15 mm thick screed bed in CM 1:4 for laying floor tiles .
M&L for Light shade vitrified tiles 10mm thick (square/rectangular) polished, area of each tile not exceeding .36 sqm,in floors etc set and jointed in neat cement slurry and pointed in white/coloured cement to match the shade.
M&L for PCC 1:3:6 type C-1(20 mm graded aggregate) precast cement concrete block masonry with solid blocks exc 10 cm in width and setting in CM 1:6 etc complete.
M&L precast solid block masonry of block 1:2:4 type B-1 wall exceeding 10 cm in width and built in cement mortar 1:4 complete all as specified and directed.
M&L for precast cement concrete 1:3:6 type C1 using 20 mm graded aggregate block solid building blocks or slabs in not exc 10cm thick (with plain or interlocking joints as directed ) complete set in CM 1:4
M&L for 75 mm thick plain cement concrete type C-2, 1:3:6, (40mm graded stone aggregate)as in plinth protection, finishing the top surfaces even and smooth W/O using extra cement.
Dismantling of wall and ceiling boards(fibre pulp,insulation,etc)or insulation boards/slabs/blankets any thickness, including cover fillets and snap grid.
Supply and fix 600mmx600mmx4mm thick ‘E’ Board Classic (Make-Everest industries Ltd) as in false ceiling including supply and fixing GI ‘Tee” grid frame work made of special section of M.S galvanized sheet 0.30mm thick , bottom portion painted with cellular nitro painting, warping the suspending wire around the existing wooden/steel purlin /rafter for suspending grid frame work of size 605mmx605mm suspended with 4 mm dia GI wire @ 1200mm c/c on main Tee and fixed to T-grid with the help of level clip or as per manufacturer direction. The section consisting of main Tee 37mmx24mmx0.60mm, cross runner tee 37mmx24mmx0.60mm and perimeter angle of 24mmx24mmx0.50mm thick. Perimeter angle to be fixed to wall with GI screw of 40mm long @ 450 mm c/c along the perimeter of wall including applying two coats of distemper oil emulsion complete all as specified and directed
S & F 2nd class hard wood plain solid straight chowkats and frames, wrought, framed rebated on the solid rounded or chamfered, put together with glue pinned at joints complete
S&F 30mm flush shutters, solid core construction with particle board core and plywood face panels, commercial type on both side and both face is covered with decorative face veneer with lipping/frame tp match all as completed and specified as directed.
M & L for 50 mm thick II nd class Hard wood clean sawn boarding with butt joints fixed with nails in any situation.
S&F 6 mm thick ply wood, grade BWR, type BB, fixed with nails to timber frame work on wall surfaces.
Taking down chowkats or frames with shutters (without taking off shutters from the frames) area exceeding 1.50 Sqm but not exc 4 Sqm.
Taking down chowkats or frames with shutters (without taking off shutters from the frames) area not exceeding 1.50 Sqm
M & L for Second class hard-wood in scantlings for timber framed work and fixed
M & L for Cub-boards shutters made with 19mm thick prelaminated particle board with decorative lamination on one side and other side balancing white lamination medium density, interior grade including 6mm teakwood lipping complete all as specified and as directed.
S&F continuous hinges (Piano) hinges,30mm brass,brighgt finish or electro galvanised
S&F 75 mm long mild steel handles, oval type, stove enamelled black , complete all as specified and as directed.
M & L for preparing new wooden surfaces of any description, not otherwise described over 10 cm in width or girth and applying two coats of synthetic enamel paint over a coat of pink primer.
Material and labour for complete removal of existing treatment and appling two coat of cement base paint over one coat of primer complete all as specified
S&F Towel rail 600mm long of PTMT fixed with and including CP brass screws and wooden/plastic cleats.(minimum wt-190gms)
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and as directed.
Dismantling plain or corrugated steel sheeting of any thickness as in roof coverings/wall cladding complete all as specified and directed.
S&F Pre-Painted galvatume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of an colour havimg testile strenght of 550 Mpa as in roof covering/ cladding to wall , fixed with self tapping screws as specified and directed.
S&F pre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, ridge , Gutter, Gable flashing, corner flashing etc, fixed with self tapping screws as specified and directed.
S & F roof trusses (framed), trussed, purlines, crane grantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance piecces, cleats, plates etc confirming to Fe.290.Gde-E-165.
M & F for Solid PVC Wall Lining consisting of 5 mm thick Plain colour PVC sheet inclusive of solvent cement and fixing at site on PVC frame as per specifications and drawing
M & F for 5mm thick PVC sheet fillet of width 35mm for wall paneling inclusive of fixing on to wall to make PVC Frame as per specification and drawing.
S&F for Powder coated (minimum thickness of powder coating 50 micron) anodised aluminium window and ventilator shutters with three track (sliding type) or one fixed frame and other two track sliding as necessary , aluminium section weighing not less than 0.55 Kg/m including 5 mm glass,Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.4mm and fixed with stainless steel wire staples,aluminium anodised grill of design DG 104 pattern, made out of 10mm dia rod fixed with and including standard aluminium frame of F section of size 23.40mm x 15.30mm x 1.40mm thick and necessary joining cleats, glazing clips, rubber neoprene packing, anodised aluminium snap beading screws and locking system etc. complete all as specified.
Taking up or down 15 mm bore steel water tubing and connections including clfor refixing or removal to store
S&F 15mm bore steel water tubes, medium grade, galvanised with all fittings and fixed complete to walls/ceilings or laid in trenches.
S&F PVC connections 15 mm size with PTMT nuts of length 450 mm.
S&F 15mm stop valves alloy,screwed down , high pressure,with crutch or butterfly handle,screwed both ends for iron pipe but fancy type,chromium plated
S&F sink with drainage board made of stainless steel 1.00 mm thick kitchen with plug washers, wastes;including bedding in cement mortor on dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915 x 460 mm with bowl size 410 x 330 x 160mm, complete.
S&F 15 mm bore chromium plated fancy type pillar tap cast copper alloy with capstan heads, screwed down high pressure,with or without leterred "Hot ot Cold" with long screwed shanks and fly nuts screwed for iron pipe complete all as specified and directed.
S&F 15 mm dia bib taps, fancy type chromium plated, screwed down, screwed for iron pipe or for brass ferrule and fixed.
Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc.complete all as specified and directed.
M&L PCC in surface channels and drains type B2 (1:2:4) using 40 mm graded stone aggregate
M&L for rendering 15mm thick in cement mortar 1:4 on fair faces of brick masonry or concrete surfaces of walls, mixed with water proofing admixture (ISI marked), finished even & smooth without using extra cement complete all as specified. Note : - Supply only water proofing admixture shall be measured and paid for separately.
Rendering 20mm thick on fair faces of brick work or concrete surface in cement plaster 1:4, with WPC 3% by weight of cementfinished even and smooth without using extra cement completed all as specified and directed.
M & L for 15mm thick Rendering on fair faces of brick work or concrete surfaces with CM 1:6 complete all as specified and directed.
Extra for forming fair finished drain or channel 60 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped end etc complete all as specified and directed.
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped end etc. complete all as specified and directed.
Formwork to sides of concrete foundations, footings, bases of columns raft and raft beams sides and soffits of foundation and plinth beam and similar wk vertical or to batter
M&L for Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. in flat surface complete all as specified and directed.
S&F of flat Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping
M&L for flat Formwork to faces of Baffle walls, retaining walls, abutments, parapets and staircase railings and similar work including attached pillasters, buttresses, etc.; vertical or to batter complete all specified and directed
Supply only integral liquid water proofing compound complete all as specified and directed.
M&L for pre cast re-inforced cement concrete 1:2:4 type B-1 as in cover slab for man hole and similar article with plain face set in Set in CM 1:4 complete all as specified and directed.
M&L for Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia orsecuring with clips complete all as specified and directed.
M&L for Mild steel TMT bars 6mm to 8mm dia, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia., or securing with clips.
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth; for foundation/sewage line and getting out in hard/dense soil complete all as specified and directed..
Excavation in trenches but not exceeding 3.00 mtr in depth for foundation/sewage line and getting out in hard/dense soil complete all as specified and directed..
M & L PCC 1:4:8 type D2( using 40mm graded aggregate ) as in foundation filling and mass concrete etc.
M & L for PCC 1:2:4 type B-1 using 20mm grade stone aggregate as in coping & Drain complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm. in hard/dense soil complete all as specified and directed.
Removal of excavated soil to a distance exc.50 Mtr and n.exc. 100 Mtr and deposited as directed by Engineer-in-Charge.
M&L for cement concrete type C-2, 1:3:6(40mm graded agg) in Cement concrete in foundations, filling and mass concrete complate all specified and directed
Loose filling with broken bricks aggregates of gauge 80 to 150 mm in sockage wells complete all as specified and directed.
M & L for RCC type B1 1:2:4 (20 mm stone aggregate)Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the likecomplete all as specified and directed.
M&L for re-inforced cement concrete 1:2:4 type B-1 (20mm graded aggregate) as in beams, plinth beams, cantilevers, bressummers, lintels over 1.5 m span etc complete all as specified and directed.
M&L for Reinforcement cement concrete type B0 1:2:4(12.5mmgraded aggregate) in Walls, retaining walls, basementwalls, ballast walls and the like;any thickness; above top of footings; including attachedpilaster and buttresses
M & L for salt glazed stone ware drain pipes 150mm complete all as specified and directed.
S&F PVC (SWR) pipes single socketed 110mm dia in any length with rubber ring joints fixed to walls
S&F PVC (SWR) bends any radius, bend 110mm dia with access door
S&F PVC (SWR) junction single, (single T) equal or unequal with access door 110mm dia.
S&F PVC (SWR) pipes single socketed 75mm dia in any length with rubber ring joints fixed to walls
M&L for Bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates; hook and pintle hinges: large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165
S&F Mild steel bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for Iron steps Fe-410-W (Gde.E-250) quality-A orFe 290 (Gde -E-165)complete all specified and directed.
Material and labour for providing PCC (1:3:6) type C-2 as in concrete bed to drain pipes including packing under and haunching against the sides of pipes of 110 mm on after they are laid and tested complete all as specified and directed..
S&F PVC Vent cowl of 110 mm dia complete all specified and directed
S&F PVC Vent cowl of 75 mm dia complete all specified and directed
Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out in hard/dense soil.
Excavating in post holes (or similar holes) each n.exc 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm in hard / dense soil.
M&L for Hardcore of gauge exc. 63 mm but n.exc 100mm,with broken stone or boulderts deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and directed by engr in charge.
M&L for plain cement concrete 100mm thick type B2 1:2:4 (using 40mm graded aggregate) complete all as specified and directed by engr in charge
M&L for PCC 40 mm thick type B-1, 1:2:4 (20mm graded aggregate) as in sub-base, floors and pavings etc and finished even and smooth without using extra cement complete all as secified and directed.
M&L for Sand filling under floors or in foundations including watering and consolidation complate all specified and directed
M&L for Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade with grey cement and pigments complate all specified and directed
S & F Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240 complete as specified.
M&L for preparation of newly steel surface of any description, over 10cm in width or girth,not otherwise described with two coat of synthetic enamel paint over a coat of red oxide primer.
M&L for PCC 1:2:4 type B-2 using (40 mm graded stone aggregate) in walls or retaining walls, any thickness, size or shape including pilasters, buttresses columns, pillars, boundary pillars and posts (including caps and bases).
M & L for Preparing newly surfaces plastered or unplastered with three coats of white wash complete all as specified and directed.
M&L for 100 mm thick PCC 1:4:8 type D-2, (using 40 mm graded granite stone aggregate) in floorings including finishing the surface even and smooth without using extra cement all as specified
M & L for Screed bed or bedding layer of mortar 20 mm thick for laying floor finishes with CM1:6 complete all specified and directed
M&L Chequered cement concrete tiles 30cm x 30cm x 25mm thick,set, jointed and pointed in neat cement slurry in floors with grey cement and no pigments.
Taking down copper/aluminium point wiring (light, Bell, fan, socket or power) complete and removing material to store for keeping in safe custody or for taking credit and making good the disturbed surfaces of wall /ceiling so as to match with the existing finishes complete all as specified and as directed.
M&L for point wiring with 1.5 sqmm(nominal area),two single core PVCinsulated unsheathed,1100 volts grade,multi stranded copper conductor ,in and including PVC casing capping of adequate size with all fittingsand acessories including PVC board with top cover housing/mounting brackets switches,sockets etc,including PVC insulated unsheathed single core multi stranded copper conductor cable of size 1.5 sqmm green in colour as earth continuity conductor connected to common earth dolly for one light/fan point controlled by one way switch complete all as specified and directed.
M & L for point wiring with One 3 pin socket outlet 6/5 Amps controlled by one switch on the same board with other switches.
One 3 pin 6/5 Amp socket outlet controlled by one switch indep board.
All as per item ser No 93 here in before but for 3 pin 15 Amps socket outlet independent board drawn from DB and including PVC insulated multi stranded copper conductor 2.5 sqmm 1100 volts grade and wire earth continuity wire 2.5 sqmm PVC insulated copper wire (Green) including PVC casing and capping complete all as specified and as directed.
S&F switch piano flush type single pole one way 5 amp 240 volts all as specified and directed.
Supply and fixing Socket outlet 2 in 1, 3 pin, 5A
S&F switch socket combination 2 in 1, 3 pin, 6 Amp piano flush type (ISI marked), 240 Volts including taking down unserviceable one complete all as specified & directed.
S&F for switch socket combination multiporpose 15 A flush type,5 in 1,240 volts all as specified and directed.
S&F Ceiling rose, surface bakelite, 65x50mm, two to three terminals AC,230 V complete all as specified and as directed
Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete.
Supply and fixing LED light fitting 1X20 watt, 220V AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed by Engr in charge.
S&F LED light fitting 1x9W/1x10W bulkhead luminaire including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete as specified and directed by Engr in charge.
S&F sheet metal enclosure for DBs SPN 8 way,with 200 amp rated bus bar Double door complete all as specified and directed. .
Supply and fixing SP 5 to 32 amp, 240V 10KA 'C' curve MCB complete with testing and commisioning
Supply and fixing SPN 40 amp, 240V 10KA 'C' curve MCB complete with testing and commisioning
Supply and fix exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, 1200 RPM, copper winding of sweep 300 mm including necessary elect connection all as specified and directed by Engr in charge.
Supply and fix electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc.
Supply and install hi wall split units indoor/outdoor complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with minimum 3 star rating and EER 3.2 of capacity 1.5 TR complete all as specified and directed.
Supply and fix TPN DBs with double door with suitable for MCCB FP 63 Amp with all as sapecifed and diretcted.
M&L for surface sub main wiring with two single core PVC insulated unsheathed 1100 volt grade multi stranded FRLS Copper conductor cable of size 6.0 sqmm (Nominal area) drawn through in and including PVC casing caping/PVC conduit size with all fittings and accessories alongwith one single core green colour PVC insulated unsheathed 1100 volt grade multi stranded FRLS Copper conductor cable of size 4.0 sqmm as earth lead and connected to earth dolly including taking down unserviceable one and making good to disturbed surfaces complete all as specified and directed. NOTE: (a)Two run of cable with one run of earth wire and one run of casing capping/conduit will be measured as one length.
M&L for surface sub main wiring with two single core PVC insulated unsheathed 1100 volt grade multi stranded FRLS Copper conductor cable of size 4.0 sqmm (Nominal area) drawn through in and including PVC casing caping/PVC conduit size with all fittings and accessories alongwith one single core green colour PVC insulated unsheathed 1100 volt grade multi stranded FRLS Copper conductor cable of size 2.5 sqmm as earth lead and connected to earth dolly including taking down unserviceable one and making good to disturbed surfaces complete all as specified and directed. NOTE: (a)Two run of cable with one run of earth wire and one run of casing capping/conduit will be measured as one length.
M&L for surface sub main wiring with two single core PVC insulated unsheathed 1100 volt grade multi stranded FRLS Copper conductor cable of size 4.0 sqmm (Nominal area) drawn through in and including PVC casing caping/PVC conduit size with all fittings and accessories alongwith one single core green colour PVC insulated unsheathed 1100 volt grade multi stranded FRLS Copper conductor cable of size 2.5 sqmm as earth lead and connected to earth dolly including taking down unserviceable one and making good to disturbed surfaces complete all as specified and directed. NOTE: (a)Two run of cable with one run of earth wire and one run of casing capping/conduit will be measured as one length.
Earthing complete with galvanised steel earth electrode plate of size 600x600x6mm thick, buried directly in ground (earth pit nbot less than 2.25m deep below normal ground level) with top edge of the plate not less than 1.50m below notmal ground level, connected to galvanised earth lead wire 4.0mm dia by means of suitable GI nuts/bolts and brazed properly up to main board including earth pit in cement concrete 1:2:4 type B-1, precast RCC cover in 1:2:4 reinforced with expanded metal, with suitable handle, excavation and earth work in any type of soil and including medium grade GI watering pipe 25mm bore with funnel wire mesh and medium grade GI wire protection pipe 25mm bore up to main board complete as shown in electrical plate No 3 of MES schedule Part-I 2009, connected to earthing testing point including taking out existing unsv earthing complete all as specified and testing on completion complete all as specified and as directed. Note:- The units rate including the cost of excavation & earth work in any type of soil, charcoal & salt in alternate layers, 25mm GI pipe (light grade) for watering 25mm GI protection pipe (light grade) funnel wire mesh PCC chamber in PCC 1:3:6 type C-1 cast iron frame and 40mm thick RCC cover for pit etc & no extra payment will be made.
Supply and fix MCCB 63 Amps FP complete all as specifed and diretced
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq mm 4 core
Supply and laying un-reinforced precast.concrete cable protection cover of class LV, type-1, flat size 250mm x 150mm x 40 mm, factory made of specified make , complete all as specified and directed.
M/S R L SHARMA (BID ID -3247386)
Sikha Traders (BID ID -3246852)
M/S SUNRISE CONSTRUCTION AND CO (BID ID -3247002)
M/S N D ENTERPRISE (BID ID -3245754)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .