Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.8 LAccepted-AOC AT PRATAP BAGAN LANE NO 07 P O BANKURA DIST BANKURA PIN 722101 | BANKURA | BANKURA | WEST BENGAL | 722101 | L1 | Accepted-AOC AOC | |
| 2 | L2₹2.8 L+₹390 (0.14%)Rejected-Finance 334 SCHOOL DANGA BANKURA BANKURA WEST BENGAL 722101 | BANKURA | BANKURA | WEST BENGAL | 722101 | L2 | Rejected-Finance 2nd Lowest | |
| 3 | L3₹2.8 L+₹876 (0.31%)Rejected-Finance 334 1 SCHOOLDANGA BANKURA 722101 | BANKURA | WEST BENGAL | 722101 | L3 | Rejected-Finance 3rd Lowest |
Tender Value
Refer Docs
EMD Value
₹5,600
Closing Date
2 Jul 2024, 10:55 amClosed
AE/BMCESD/PWD
Kenduadihi, Gobindanagar Hospital campus, Bankura-722102
Supply Installation of new Split AC machine for Server room at Super Speciality Block 3 rd floor (24 hrs run basis ) including necy electrical installation work.
2024_WBPWD_699265_1
WBPWDTE/ AE /BMCESD /NIQ-10/ Q of 2024-25
Open Tender
ELECTRICAL WORKS ORG
Item Wise
14 days
AE/BMCESD/BANKURA
Please refer Tender documents.
3 documents required · 3 mandatory
₹5,600
Yes
22 Aug 2025
25 Jun 2024
4 Jul 2024
25 Jun 2024
2 Jul 2024
25 Jun 2024
Amount
Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed on wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment Make-Legrand/ Siemens/L & T/ ABB ) as to GS. 2+12 way Enclosure
Supplying and fixing MCCB SS enclosure with IP-20/30 protection, powder coated provision for four pole MCB/MCCB , concealed in wall after cutting the wall & mending good the damages to original finish/ on flat iron frame incl. painting, connection & provision for earthing attachment (Make -Legrand/ Havells/L & T/ ABB) 2 Way (UPS Incoming & Outgoing)
Supplying and fixing 240/415 V Isolator on din rail of existing DBs and necessary connection Make-Legrand / Siemens, as to GS. /L & T/ ABB 240 V, 40A DP
Supplying and fixing 240/415V, MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection Make-Legrand/ Siemens as to GS. /L & T/ ABB 6A - 32A SP MCB
Supply & Fixing 240 V, 4 nos. 16 A, 3 pin Modular type plug socket with 4 nos. 16A Modular type switch (Brand approved by EIC), 20A Modular switch type SP MCB (C-Curve) and Indicator without plug top on 2 row 18 Module GI Modular type switch board with 2 row 18 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc
Distribution wiring in 1.1 KV single core stranded 'FRLS' PVC insulated & unsheathed copper wire (Havells/ KEI / Gloster/RR Kabel /approved by EIC) in 20 / 25 mm size PVC rigid conduit 'FR' (Precision make) incl. necy. fittings as required. 2 x 2.5 sq mm + 1 x 1.5sq mm ( for computer board)
2 x 4 sqmm + 1 x 2.5sqmm (UDB TO UPS INPUT , UPS OUTPUT TO UPS LDB & PDB TO AC POWER PLUG)
Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes. as per G S 2.5 sq mm
Supply & Fixing of 250V 50 HZ OLP- 30A single phase A.C Starter ( Make -Electron, / PWD Appvd ) suitable for 1.5 / 2.0 TR Airconditioner Machine incl S & F suitable size G I box (16 SWG) flushed in wall with voltage check, Amp check, Time check incl. making connection as per direction of EIC.
Supply & Fixing 240 V, 25 A, 3 pin Modular type plug socket (Brand approved by EIC), without plug top and switch with 2 Module GI Modular type switch board with top cover plate flushed in wall and making necy. connections with PVC Cu wire and earth continuity wire etc as per G.S.
Supply & Fixing 240 V,25 A, 3 pin Modular type plug top with indicator (Brand approved by EIC) & necy. Connections.
Supplying and fixing Timer panel made of 16 way Distribution Board with transperent front door and din rail for mounting the following items included. per direction EIC.The Box shuld comprising following accessorise. A) 230 V , 50 Hz ,16 Amp Single dial 1 x 24 Hrs.Timer similar to ( Microrex QT31 ) of quartz driven running reserve Day dial back up by nickle cadmium battery (Make - GEC / Legrand ) – 1 no B) One no. ML-3 conctractor,(L&T make) with ( 2 NO or 1 NO + 1 NC Aux. Contract ) ( Make - Legrand / L & T ) – 1 no C) 4 pole 32 Amps MCB ( L & T / Ligrand ) - 1 no D) Auto / Manual By pass Toggle Switch arrangement – 1 no. E) 250 V , Diode type neon Indicator lamp ( Make - Legrand /L&T) – 1 no F) Bakelite base with FP bolt type stud / Terminal block incl S & F Neutral Bar , with spring washer ,nuts etc with this box for termination of power to complete arrangement must be wiring by 4 Sq mm PVC insulated Cu wire with suitable length incl socketing /lugs etc as per requirement & direction of EIC (for controlling AC Machine) (Make - Legrand /L & T / Crabtree )
Supply & Delivery of 230V, 50Hz rated 2.0 ton capacity Split Air-conditioner machine fitted with Hyper Tropical Rotary compressors suitable for Refrigerant-R410A/ R32, Standrad Colling Capacity 6450 W Power Consumption Capacity 1870W Moisture Removal 2.3 I/H Air Flow 1060 Cu.Mt/Hr. (Make- O-General Model-AOGG22CKTC-B or equvalent model of Hitachi/Daikin/ PWD Appvd ) with Remote etc . to complete with 25 Amp suitable plug top (North West / appvd ) as per direction of EIC)
Installation, Testing & commissioning of 1.5/2.0 Tr. Split type AC both indoor/ outdoor unit incl. S& F of 40 X 40 X 5 mm MS angle iron frame for installation of ODU and sealing of the holes in wall created during the copper pipe connection between IDU & ODU by proper sand-- cement plastering and painting (both inside and outside) to match up with the original finish mending good the damages to complete the instn as per direction of EIC
S& F laying of - (i) gauge copper pipe 5/8" 0.7 mm thick for suction (ii) copper pipe 1/4" 0.6 mm thick for discharge (OEM make) with 9 mm thick thermal insulation foam nitrile / rubber / K Flex / Accroflex with max saddling with max 1 mtr distance both for suction & discharge pipe and mending good the holes & damages as directed by EIC. (extra length for distance of ODU & IDU exceed 3 mtr.)
S& Laying 4 core 2.5 sqmm PVC insulated & unarmoured copper wire (make-- Finolex/Havells/KEI) for 1.5/2 Tr. Split AC machine (extra length for distance of ODU & IDU exceed 3 mtr.) with max saddling with max 1 mtr distance as per direction of EIC.
S & F of flexible PVC high quality water carrying pipe of proper size for draining water from already installed AC to any available (nearest) drain water pipe or near to ground level and the pipe must be properly saddled with the wall incl. proper insertion of the flexible pipe to drain water pipe and sealing the entry with required materials like PVC tape, High quality sealing the entry with required materials like PVC tape, high quality sealing gum etc. as reqd. All these arrangement for fixing must be arranged by the agency itself as per direction of EIC.
Dismantling , shifting & re installation of 3 KVA On line UPS from Natun Bhawan server room to SSB Server room
Febrication of iron Bracket/ platform which consist of five nos.75 x 40 x 5 mm 'C' channel aprox length of each 1.4mtr. as main support, 50 x 50 x 6 mm iron angle for main frame & cross angle support from wall to structure, 25 x25 x 5 mm iron angle for safty guarding fram, 25 x25 x 5 mm iron angle for making 450mm wide both side platform of out door unit for future maintenance work, it should have the facility to install Two outdoor unit of split AC machine at middle of the bracket and sufficent space should be maintained both side of the outdoor unit for maintenance work also have suitable angle support between wall & bracket and painting the same incl. drilling holes in each Angle including cutting holes into the wall & grouting the same with (1:1 ½ :3) cement concrete etc. and painting the same as per direction of EIC.
Swarnendu Sarkar
TAPAN KUMAR SARKAR
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .