| Sl No | Description | Qty | Unit | AJAY KUMAR LENKA | Chem Coating |
|---|---|---|---|---|---|
| 1.00 | Chipping of unsound/weak concrete material from slabs, beams, columns etc. with manual Chisel and/ or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts all complete.25 mm to 50 mm average thickness of chipping.The work also includes filling the undulations and leveling/rendering the chipped surface with rich mortar in the propertion of 1:3(1 cement:3 coarse sand) and applying 2 coats of Dr. Fixit Pidifin 2K over the erendered surface per direction of Engineer-In-Charge. | 1,700 | Sqm | 1,70,000 ₹1,70,000 | 30,600 ₹30,600 Lowest |
| 2.00 | Cleaning of reinforcement from rust from the reinforcing bars to give it a total rust free steel surface by using alkaline chemical rust remover of approved make with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washing with water and allowing it to dry, all complete as per direction of Engineer-In-Charge.(Approved Brand : Dr. fixit, FOSROC) | 70 | Mtr | 31,710 ₹31,710 Lowest | 56,000 ₹56,000 |
| 3.00 | Providing, mixing and applying bonding coat of approved adhesive on chipped portion of RCC as per specifications and direction of Engineer-In-charge complete in all respect.SBR Polymer (@10% of cement weight) modified cementitious bond coat @ 2.2 kg cement per sqm of surface area mixed with specified proportion of approved polymer. (Approved Brand:Dr. Fixit, FOSROC) | 400 | Sqm | 1,50,000 ₹1,50,000 | 1,12,000 ₹1,12,000 Lowest |
| 4.00 | Providing and laying a rendering screed of avg 50 mm thick in 1:2:4 ratio (cement:sand:6 mm down aggregate) admixed with Dr. fixit Pidicrete URP @ 15% by weight of cement or as per requisite % as recommended by the manufacturer & sandwitched with 24 gauze chicken wire mesh all in complete including khurras with neat good finish all in complete. And allow the surface for water curing for minimum 15 days. (Approved Brand : Dr. Fixit, FOSROC) | 85 | Cum | 3,82,500 ₹3,82,500 Lowest | 7,22,500 ₹7,22,500 |
| 5.00 | Providing and laying 120 gsm geotextile membranes with an overlap of 100 mm on the cured membrane surface with suitable adhesive all in complete | 1,700 | Sqm | 4,59,000 ₹4,59,000 | 2,21,000 ₹2,21,000 Lowest |
| 6.00 | Providing and applying fibre reinforced elastomeric liquid water proofing membrane with resilient acrylic polymers having Sun Reflectivity Index (SRI) of 105 on top of concrete roof in three coats @10.76 litre/ 10 sqm. One coat of self-priming of elastomeric waterproofing liquid (dilution with water in the ratio of 3:1) and two coats of undiluted elastomeric waterproofing liquid (dry film thickness of complete application/system not less than 500 microns). The operation shall be carried out after scrapping and properly cleaning the surface to remove loose particles with wire brushes, complete in all respect as per the direction of Engineer-in-Charge.(Approved Brand: Dr. FIXIT Roofseal Select Terracotta, FOSROC, )
NOTE 1:Water proofing test with filling water on roof top for 4 days has to de done before handing over the site.
NOTE 2: Guarantee of waterproofing for a period of 10 years ( from approved manufactueres i.e. FOSROC/Dr.FIXIT or company's approved applicator) from the date of completion of the work in the specific areas. Any leakages occurring during this period due to defective material or bad workmanship shall be rectified free of cost. | 2,000 | SQM | 4,20,000 ₹4,20,000 Lowest | 7,00,000 ₹7,00,000 |
Tender Value
₹21.2 L
EMD Value
₹50,102
Closing Date
30 Mar 2026, 5:30 pmClosed
REGISTRAR
Institute of Physics,PO-Sainik School,Bhubaneswar
Waterproofing of roof top of ION beam laboratory in IoP Campus
2026_IOPB_902000_1
NIT/IOP/128/2025-26
Open Tender
Civil Works
Works
60 days
Institute of Physics, PO-Sainik School, Bhubaneswar
Please refer the tender documents
6 documents required · 6 mandatory
₹0
₹50,102
Yes
29 May 2026
11 Mar 2026
31 Mar 2026
11 Mar 2026
30 Mar 2026
11 Mar 2026
11 Mar 2026 - 18 Mar 2026
Chipping of unsound/weak concrete material from slabs, beams, columns etc. with manual Chisel and/ or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts all complete.25 mm to 50 mm average thickness of chipping.The work also includes filling the undulations and leveling/rendering the chipped surface with rich mortar in the propertion of 1:3(1 cement:3 coarse sand) and applying 2 coats of Dr. Fixit Pidifin 2K over the erendered surface per direction of Engineer-In-Charge.
Cleaning of reinforcement from rust from the reinforcing bars to give it a total rust free steel surface by using alkaline chemical rust remover of approved make with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washing with water and allowing it to dry, all complete as per direction of Engineer-In-Charge.(Approved Brand : Dr. fixit, FOSROC)
Providing, mixing and applying bonding coat of approved adhesive on chipped portion of RCC as per specifications and direction of Engineer-In-charge complete in all respect.SBR Polymer (@10% of cement weight) modified cementitious bond coat @ 2.2 kg cement per sqm of surface area mixed with specified proportion of approved polymer. (Approved Brand:Dr. Fixit, FOSROC)
Providing and laying a rendering screed of avg 50 mm thick in 1:2:4 ratio (cement:sand:6 mm down aggregate) admixed with Dr. fixit Pidicrete URP @ 15% by weight of cement or as per requisite % as recommended by the manufacturer & sandwitched with 24 gauze chicken wire mesh all in complete including khurras with neat good finish all in complete. And allow the surface for water curing for minimum 15 days. (Approved Brand : Dr. Fixit, FOSROC)
Providing and laying 120 gsm geotextile membranes with an overlap of 100 mm on the cured membrane surface with suitable adhesive all in complete
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
cancelled_1.pdf
pdf • 2.52 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.15 MB
NIT128IBPROOFTOPtechnicalPLusGCC.pdf
Tender Documents • 0.59 MB
BOQ_948085.xls
BOQ • 0.33 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .