| 1 | Admitted-Fee/PreQual/Technical | Admitted-Fee/PreQual/Technical |
| 2 | Admitted-Fee/PreQual/Technical RADHA NIKUNJ L 2 SOUTH CIVIL LINES ROORKEE HARIDWAR UTTARAKHAND 247667 | ROORKEE | HARIDWAR | UTTARAKHAND | 247667 | Admitted-Fee/PreQual/Technical |
| 3 | Admitted-Fee/PreQual/Technical KG 115 SABIRA MANZIL HBR 2ND STAGE VENKATESH PURAM BANGALORE 560 045 | BENGALURU URBAN | KARNATAKA | 560045 | Admitted-Fee/PreQual/Technical |
Tender Value
₹49.5 L
EMD Value
₹99,000
Closing Date
7 Apr 2026, 6:00 pmClosed
GE North Bangalore
GARRISON ENGINEER NORTH BANGALORE T 64 MEANEE LINESMEG AND CENTRE BANGALORE 560042
SPECIAL REPAIR REPLACEMENT OF SPLIT WINDOW AC REFRIGERATOR DEEP FREEZERS CHLORINE DOSING SYSTEM AND CEILING OF FANS MEG CENTRE AGAINST BER IN THE ARMY UNITS UNDER GE NORTH BANGALORE
2026_MES_755809_1
8305
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Bangalore
Class D Category c(i)
7 documents required · 7 mandatory
₹500
Yes
GARRISON ENGINEER NORTH BANGALORE
₹99,000
Yes
2 Apr 2026
10 Mar 2026
9 Apr 2026
10 Mar 2026
7 Apr 2026
24 Mar 2026
10 Mar 2026 - 24 Mar 2026
S&F ceiling fans complete with complete accessories, 230V, SP 1200 mm Sweep with BEE 5 Star rating complete with all accessories and fixing the fan from ceiling rose with 3 core flexible copper wire 24/0.20 sqmm, etc all as specified and as directed including taking down of old unsv and deposited to MES yard
Supply and Fix Chlorine Dozing System which includes Chlorine Dozing Pump of Model (Chlorine Dozing Pump Model F31WYI) and Dozing Tank of model ( STEQUA Chlorine Dozing Tank Model SCD-24) with the following specification including dismantaling and taking old unsv chlorine dosing system and depositing it to MES store yard: (a) STEQUA CHLORINE DOSING PUMP MODEL F31WYI Item Description: Chemical feeder employing motor-driven reciprocating chemical pump having output of 2.7 U.S. GPD to 23.5 U.S. GPD and adjustable high pressure of up to 80 PSI. Additional detailed specifications: High Pressure Single Head Gear Motored Adjustable dosing hose / tube pump of following specifications: Compact metering pump with totally enclosed housing Wall mountable Self-priming against maximum working pressure Pump does not lose prime or vapor lock Pumps off-gassing solutions and can run dry Output volume is not affected by back pressure Cond/---3
Cond/---2 Output Control: Adjustable potentiometer Maximum Operating Temperature: 104°F (40°C) Maximum Suction Lift: 25 ft (7.6 m) vertical lift, based on water Motor Type: 24 VDC, brushed Shaft rpm (average maximum): 26, 44 Duty Cycle: Continuous Maximum Viscosity: 100 Centipoise Motor Voltage: 230V 50Hz (10W) Power Cord Length: 6 ft. (1.8 m) Classification: Indoor/Outdoor Materials of Construction: All Housings: Polycarbonate Pump Tube & Check Valve Duckbill: Santoprene Pump Head Rollers: Polyethylene Suction/Discharge Tubing and Ferrules: Polyethylene Tube and Injection Fittings: PVC or Polypropylene Connecting Nuts: PVC or Polypropylene Suction Line Strainer and Cap: PVC or Polypropylene; ceramic weight All Fasteners: Stainless steel ACCESSORIES 3 Connecting nuts 1/4" 3 Ferrules 1/4" 1 Duckbill check valve 1 Weighted suction line strainer 1/4" 1 20' Roll suction/discharge tubing 1/4" white or Any other Equivalent Make
Cond/---2 (b) STEQUA CHLORINE DOSING TANK MODEL SCD - 24 Item Description: Non-metallic solution tank of 100 litres capacity with motor driven agitator to maintain uniform suspension throughout the tank. Additional detailed specifications: Electrically operated Chlorine dosing tank consisting of: Dosing tank of 100 litres of PE/FRP MOC with PE/FRP Lid & Level Gauge along with Single Phase Electric Motor and Agitator with shaft & blade in Plastic - mounted on Tank. Lid must have port hole for pouring Calcium Hypochlorite and water when necessary. Lid must have provision for mounting dosing pump on the lid/wall. or Any other Equivalent Make
Supply and fix air cooled split unit air conditioner electric driven, single phase of capacity of 2.0 TR, BEE 5 star rated with inverter technology including dismantaling and taking down old unsv one and depositing to MES store.
Supply and fix air cooled split unit air conditioner electric driven, single phase of capacity of 1.5 TR, BEE 5 star rated with inverter technology including dismantaling and taking down old unsv one and depositing to MES store.
Supply and fix refrigerator, electric driven (single phase), capacity of 185 Litres or higher capacity. BEE 3 star rated or higher ratings
Supply and fix refrigerator, electric driven (single phase), capacity of 235 Litres or higher capacity. BEE 3 star rated or higher ratings
Supply and fix refrigerator, electric driven (single phase), capacity of 285 ltr. BEE 3 star rated or higher ratings
Supply and fix refrigerator, electric driven (single phase), capacity of 310 ltr or higher capacity. BEE 3 star rated or higher ratings
Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% suitable for 1.5 / 2 TR Acs.
Supply and fix Deep Freezer, electric driven (single phase), capacity of 320 ltr. BEE star rated
stage.html
html • 0.02 MB
tech_bid_open.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.25 MB
8304Tender.pdf
Tender Documents • 1.09 MB
BOQ_846574.xls
BOQ • 0.33 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .