| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹33.6 LAccepted-AOC 307 SADAR BAZAR LUCKNOW UP 226002 | LUCKNOW | UTTAR PRADESH | 226002 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹35.4 L+₹67,674.60 (1.95%)Rejected-Finance | L2 | Rejected-Finance Being L2 | |
| 3 | L3₹36.1 L+₹1.4 L (4.04%)Rejected-Finance | L3 | Rejected-Finance Being L3 | |
| 4 | Rejected-Technical | - | Rejected-Technical Due to contractor has already executed more than two works in provisional enlistment. |
Tender Value
₹39 L
EMD Value
₹78,000
Closing Date
8 Nov 2023, 6:00 pmClosed
GE E/M Lucknow
Garrison Engineer E/M, 36 LBS Marg, Lucknow Cantt, Lucknow (U.P.) PIN 226002
REPAIR/MAINT OF LT PANEL INCL LT SWITCH GEAR, EARTHING, TIMER PANEL, LT POLES, POLE BOX, STREET LIGHTS, FLOOD LIGHTS, AREA LIGHTS, LT DISTR NETWORK AND CONNECTED ITEMS AT GAUR ENCLAVE, DILKUSHA COLONY, NEHRU ENCLAVE, MGSF, RAK SF, JOGGERS PARK, MVG
2023_MES_623096_1
GE/EM/LKO/EXT(ELECT)/T-48 OF 2023-2024
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Lucknow
As per NIT
8 documents required · 8 mandatory
₹500
GE E/M Lucknow
₹78,000
Yes
30 Dec 2023
13 Oct 2023
15 Nov 2023
13 Oct 2023
8 Nov 2023
27 Oct 2023
Amount
Excavation in trenches not exc. 1.5 m wide and not exc 1.5 mtr deep in soft / loose soil for laying / taking up / taking down of cables and getting out and levelling of bottom suface to required level, including taking out & staking servicable brick for reuse all as specified and directed by Engineer- in- Charge.
Returning, filling in including spreading levelling watering and well ramming in layer n.exc 25 cm thick using excavated soil all as specified and directed.
Removing excavated soil from site to a distance n. exc 50 mtrs away and depositing where directed at a level n. exc. 1.5 mtr above the starting point all as specified and directed by Engineer-in-Charge.
M&L for providing dry river sand as in sand cushioning to under ground cable of any descreption including punning down of sand in layer all as specified and directed by Engg-in-Charge. Note: for measurement purpose any punned thickness of sand will be considered.)
M&L laying well burnt old size bricks, sub class "B" bricks, straight or curved on plan , laid flat with width equal to length of brick , laid dry over electric cable for protection complete all as specified & directed by Engr-in-Charge.
All as per srl item No 5 here-in-before but using old bricks obtained under srl item No 1 here in before.
M&L for demolition /cutting of road/ path/hardstading/ concrete in floor, etc for laying of cable complete all as directed at site by Engr-in-charge
Material and labour for PCC 1:2:4 type B-2 using 40 mm graded stone aggregates for filling of cutting of roads / path / hardstanding etc complete all as specified and as directed by Engineer-in-Charge.
Deployment of manpowe / tools for Boring / drilling (Horizontly) manually / mechanically under existing road max 10 M in width) suitable for passing tubing 40 to 100 mm bore complete all as specified and directed by Engineer in Charge
S&F 80 mm dia bore mild steel galvanized iron tubes, 'light grade' with all fitting and laid in trenches or fixed to pole or laid in floors for protection of cable including taking down old pipe complete all as directed
S&F 50 mm dia bore mild steel galvanized iron tubes, 'light grade' with all fitting and laid in trenches or fixed to pole or laid in floors for protection of cable including taking down old pipe complete all as directed
S&F 40 mm dia bore mild steel galvanized iron tubes, 'light grade' with all fitting and laid in trenches or fixed to pole or laid in floors for protection of cable including taking down old pipe complete all as directed
Material & Laying, jointing and testing in replacement of LT under ground electric power cable crossed linked polyethylene ( XLPE) insulated, galvanised steel strip or wire armoured, ISI-7098 Marked, with aluminium conductor multi stranded , heavy duty 1100 Volts grade of size 10 sqmm cross sectional area, 2 core ,complete all as specified laid in trenches/ laid under floor or fixed naked with walls / on poles/ in ducts /in GI pipes etc. with and including MS Clamps, nuts , bolts, washers complete all as specified and directed. Note :- Excavation, earth work, sand cushioning, protection bricks/ tiles/ block and pipe shall be measured and paid separately under appropriate items.
All as per item No 13 above but LT UG cable of size 16 Sqmm 2 core
All as per item No 13 above but LT UG cable of size 16 Sqmm 4 core
All as per item No 13 above but LT UG cable of size 25 Sqmm 4 core
All as per item No 13 above but LT UG cable of size 35 Sqmm 3.5 core
All as per item No 13 above but LT UG cable of size 50 Sqmm 3.5 core
All as per item No 13 above but LT UG cable of size 70 Sqmm 3.5 core
All as per item No 13 above but LT UG cable of size 95 Sqmm 3.5 core
All as per item No 13 above but LT UG cable of size 120 Sqmm 3.5 core
All as per item No 13 above but LT UG cable of size 185 Sqmm 3.5 core
All as per item No 13 above but LT UG cable of size 240 Sqmm 3.5 core
M&L Earthing in replacement complete with galvanised steel earth plate electrode 60cmx60cmx6.0mm thick, burried directly in ground to a depth not less than 2.25 metres deep below ground level with top edge of earth plate not less than 1.5 metre below normal ground level surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15 cm all around the plate, using GI strip 32 x 6 mm as earth strip electrode bolted or rivetted to earth plate at one end and connected to equipments at another end, GI earth strip encased in and including 40 mm dia GI 'light grade' pipe from upper end of earth plate upto equipments,20 dia bore GI pipe 'light grade' as water pipe from earth chamber to upper edge of earth plate, Test point , GI funnel with wire mesh fixed on water pipe and PCC 1:2:4 type B-1 (using 20mm graded stone aggregate) as in pit chamber and RCC pit cover 50mm thick precast RCC 1:2:4 type B-1, duly reinforced with MS TMT bars 8mm dia @ 100 c/c both ways with 10mm dia MS round bar as in lifting handles, excavation, earth work including laying the GI pipe concealed in floor/wall all as described in electric plate of SSR Part I complete all as specified and directed and testing on completion. Note :- If the desired earth resistance is not found, earthing shall be redone by the contractor at no extra cost to the department.
Earthing in replacement complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below normal ground level surrounded from all sides by 15 cm thick packed layer of charcoal dust and common salt filling in alternate layers and electrode connections by mean of GI wire 4 mm dia by means of bolts, nuts check nuts and washers of GI or steel and connecting to earthing test point, main switch board, testing on completion including PCC cover and frame, PCC (1:3:6) type C-2 as in earthing pit, MS funnel with wire mesh GI pipe 20 mm dia light grade for watering and GI pipe 15 mm dia light grade for the protection of GI wire from earth pit to earth point complete including necessary excavation and earth work in any type of soil, returning, filling in approved soil and disposal of surplus soil to a distance n.exc 50 m all as specified as shown in electrical plate No 5 SSR Part-I. PCC chamber shall be constructed at least one metre away from the earth pit and GI pipe fittings for watering shall be provided up to chamber and cost of the same is deemed to be included in the rate of earthing. Note :- If the desired earth resistance is not found, earthing shall be redone by the contractor at no extra cost to the department.
Disconnecting the existing cable from Panel / Pole, removing the old end termination joint, preparing the end for jointing, supply and fix Cable end termination heat shrinkable joint including sleeves suitable for LT XLPE cable of size 3.5 / 4 core 10 to 16 Sqmm and reconnecting the cable with panel etc.
All as per item No 26 above but size 25 to 50 Sqmm
All as per item No 26 above but size 70 to 120 Sqmm
All as per item No 26 above but size 150 to 185 Sqmm
All as per item No 26 above but size 240 to 300 sqmm
Deployment of manpower & tools / machinery for fault finding in UG cable by disconnecting faulty 1.1 KV LT cables of different sizes from both ends, testing the cables with high voltage DC testing machine and locating the fault in the cables by fault locating machine to pin point exact position of fault, Re-connections and testing of cables after removal of fault complete all as specified and directed. Note: (a) 1.1 KV LT cable & joints will be measured and paid for separately under respective items of BOQ (b) Contractor or his rep shall come to the site of breakdown within one hour of notification of breakdown along with fault locating machine and manpower. In case the rep or contractor not come to the site of breakdown and start attending breakdown within 1.00 hour a penalty of Rs 1000 per fault per hour will be imposed over contractor and will be deduct from his dues.
Taking out faulty underground 1100 Volt LT cable of different sizes from trenches and relaying in the same trenches after rectification of fault or replacing faulty portion of cable with new cable complete. Note: (a) 1100 Volt LT cable & joints will be be measured and paid for seperately under respective items of BOQ. (b) Excavation, removing / relaying of brick old / new, sand cushning, returning & filling will be measured and paid for seperately under respective items of BOQ.
S&F Cable jointing kit for straight through joint, heat shrink type joint for 1100 V grade cable complete with jointing material and accessories suitable for 3.5 / 4 core, 10 to 16 Sqmm XLPE armoured aluminium conductor cable. Note:- Excavation and earth work, extra cable if required will be measured & paid seperatly under respective items of this BOQ.
All as per item No 33 above but size 25 to 50 Sqmm
All as per item No 33 above but size 70 to 120 Sqmm
All as per item No 33 above but size 150 to 185 Sqmm
All as per item No 33 above but size 240 to 300 sqmm
Supply & Fix in replacement twin core, 6 sqmm nominal cross sectional area multistranded aluminium conductor cable, over all PVC sheathed, 1100 Volts grade heavy duty cable PVC insulated and PVC sheathed complete all as specified.
Supply & Fixing in replacement twin core, 10 sqmm nominal cross sectional area multistranded aluminium conductor cable, over all PVC sheathed, 1100 Volts grade heavy duty cable PVC insulated and PVC sheathed complete all as specified.
Supply, fixing, connecting and testing in replacement MCCB 63 Amp 4 pole 25 KA 415 volts 50 Hz adjustable thermal & fixed magnetic release with spreader after taking down old existing unserviceable MCCB complete all as directed.
Supply, fixing, connecting and testing in replacement MCCB 100 Amp 4 pole 25 KA 415 volts 50 Hz adjustable thermal & fixed magnetic release with spreader thermal magnetic release after taking down old existing unserviceable MCCB complete all as directed.
Supply, fixing, connecting and testing in replacement MCCB 125 Amp 4 pole 25 KA 415 volts 50 Hz adjustable thermal & fixed magnetic release with spreader after taking down old existing unserviceable MCCB complete all as directed.
Supply, fixing, connecting and testing in replacement MCCB 160 Amp 4 pole 25 KA 415 volts 50 Hz adjustable thermal & fixed magnetic release with spreader after taking down old existing unserviceable MCCB complete all as directed.
Supply, fixing, connecting and testing in replacement MCCB 200 Amp 4 pole 36 KA 415 volts 50 Hz thermal magnetic release with spreader after taking down old existing unserviceable MCCB complete all as directed.
Supply, fixing, connecting and testing in replacement MCCB 250 Amp 4 pole 36 KA 415 volts 50 Hz adjustable thermal & fixed magnetic release with spreader after taking down old existing unserviceable MCCB complete all as directed.
Supply, fixing, connecting and testing in replacement MCCB 400 Amp 4 pole 36 KA 415 volts 50 Hz adjustable thermal & adjustable magnetic release with spreader after taking down old existing unserviceable MCCB complete all as directed.
Supply, fixing, connecting and testing in replacement MCCB 630 Amp 4 pole 50KA 415 volts 50 Hz adjustable thermal & adjustable magnetic release with spreader after taking down old existing unserviceable MCCB complete all as directed.
S&F in replacement on load change over switch open execution of capacity 400 Amps , 4 pole , 415 volt , 50 Hz fixed in any type of existing LT panel/Feeder piller including taking out old existing unserviceable change over from panels etc complete all as directed
S&F in replacement on load change over switch open execution of capacity 250 Amps , 4 pole , 415 volt , 50 Hz fixed in any type of existing LT panel/Feeder piller including taking out old existing unserviceable change over from panels etc complete all as directed
Supply and fixing in replacement MCCB FP 125 Amps, 25 kA, 415 Volt AC, 50 Hz, complete with sheet metal enclosure of 1.6 mm thick MS sheet factory made with powder coat paint including connecting with existing system with existing cablling network including making good disturbed surfaces complete all as specified and directed. Note : The cost of suitable size fastner/Nut bolts required at site for fixing of cubical is deemed to be included in the quoted rate by the contractor.
Supply and fixing in replacement double pole sheet metal enclosure made of 1.6 mm thick MS sheet factory made with powder coat painting including 01x MCB 20 Amps 10 kA complete all as directed Note : The cost of suitable size clamp/Nut bolts required at site for fixing of enclosure on garden light post/wall is deemed to be included in the quoted rate by the contractor.
Supply drawing, connecting and testing in replacement 3 core, 1.5 Sqmm PVC insulated and PVC round sheathed` copper conductor (flexible ) industurial cable, 1100 Volts conforming to IS 694 in steel tubular poles from Junction box to street light fitting including providing suitable copper lugs all as specified and directed by Engr-in-charge.
S&F in replacement wheather proof pole mounting PVC junction box, base and door of junction box made out of SMC having outside dimention 333x233x120mm, inside dimention 300x200x105mm , single door front openable provided with hinged cover and locking arrangements with 4 Nos aluminium bas bar 63 Amps, mounted on porcelin insulator including M&L for MCB SP 10 Amp -1No, fixed on box in Din rail complete with electrical connection fixed to pole with suitable size FI clamp nut bolts and washer including embossing/painting of danger notice of size not less than 10cm x 7.5cm with letters, figures and conventional skull and bones in signal red colour on front face of junction box body Complete all as directed by Engr-in-Charge
Supply & fixing in replacement GI brackets made of 40 mm nominal bore GI pipe medium grade of required length not less than 1.5 M long, mounting brackets made out of Mild steel FI 40x6 mm of required shape ( two Nos) duly fitted with Mild steel nuts, bolts and washers and painting with two coats of synthetic enamelled paint over one coat of red oxide primer and fixed to pole / walls etc complete all as specified & directed by Engr-in-Charge.
M&L for 3.15 mm thick CRCA sheet cut to size bend to shape for replacement of door / side / compartment of LT panel of any descreption, including all fixing arramgement i.e. suitable size of hinge, nuts, bolts, washers, cutting and welding works etc, overall powder coated finish complete all as directed by Engr -in-charge.
Supply and fixing in replacement Digital VAF+PF meter with RS 485 CL1 in LT panel including taking out old existing unserviceable meter from panels etc complete all as directed
Supply and fixing in replacement of LED indication lamp including taking down old unserviceable LED indication lamp from LT panel complete as specified and directed.
M&L for Preparation of old painted surfaces of LT steel tubular pole 9 mtrs long and applying one coat aluminium paint from bottom to top and painting up to 1.5 mtr height from top of PCC coping with synthetic enamel paint one coat in black and Yellow / white alternate strip including re writing pole numbering in 8 cm height with one coat synthetic enamel paint complete all as specified & directed by Engineer –in-Charge.
M&L for Preparation of old painted surfaces of LT panel by scrapping, making good distrubed surfaces by applying putties on uneven surface to make it even and spray painting to LT panel of any size with two coat of synthetic enamel paint with desired colour complete all as specified and directed.
Cleaning of surrounding area of E&M installation around the bldg , transformer, GOD LT panel by grass cutting manually or mechanically (Bush cutter) as per requirement basis and trimming as directed by Engr-in-Charge, including taking out all shrubs, saplings with bushes and any type of vegetation and removing from site, complete all as specified and directed.
Material and labour disconnecting & taking out faulty / burnt cable of size 16 Sqmm to 50 Sqmm 3.5 / 4 core from LT panel / LT pole / main switch / changeover etc removing / cutting old lugs, removing faulty / burnt portion of cable and preparing for fresh terminals & supply & fix new aluminium lugs / thimbels of same size & pattern and refixing & reconnecting same cable in LT panel / LT pole / main switch / changeover etc including taking out additional cable from loop & making good disturbed surface complete all as directed. Note:- Each Cable will be measured & paid seperatly.
Material and labour disconnecting & taking out faulty / burnt cable of size 70 Sqmm to 120 Sqmm 3.5 core from LT panel / LT pole / main switch / changeover etc removing / cutting old lugs, removing faulty / burnt portion of cable and preparing for fresh terminals & supply & fix new aluminium lugs / thimbels of same size & pattern and refixing & reconnecting same cable in LT panel / LT pole / main switch / changeover etc including taking out additional cable from loop & making good disturbed surface complete all as directed. Note:- Each Cable will be measured & paid seperatly.
Material and labour disconnecting & taking out faulty / burnt cable of size 185 Sqmm to 240 Sqmm 3.5 core from LT panel / LT pole / main switch / changeover etc removing / cutting old lugs, removing faulty / burnt portion of cable and preparing for fresh terminals & supply & fix new aluminium lugs / thimbels of same size & pattern and refixing & reconnecting same cable in LT panel / LT pole / main switch / changeover etc including taking out additional cable from loop & making good disturbed surface complete all as directed. Note:- Each Cable will be measured & paid seperatly.
Supply and fix in replacement 15 Watt LED Post Top lanterns housing made of Die-cast aluminum spigot for mounting LED driver and spun aluminum canopy , epoxy powder coated matt black finish after phosphochromate treatment , high quality polycarbonate cover is used over LED moudule to enhance the lumen output & clear acrylic diffuser is used to provide overall glare free light , Powered by electronic integral , isolated poted electronic LED driver in ABS housing with APFC (SMPS based constanct current supply) with lower THD , output short/open circuit protection , Surge Voltage protection & other safety test as per IS 15885 Part-2/Sec-13 , IP 65 , Lumen efficiency not less than 98 lumen per watt system efficency ,power factor >0.95, THD<10% at Full load CRI> 70%
All as per item No 64 above but 25 Watt LED Post Top lanterns but Lumen efficiency not less than 100 lumen per watt system efficency
Supplying and fixing in replacement 8 Watt Bamboo LED bollard fitting of 1 meter height new generation , energy saving , enviornmental friendly , long life aesthetically designed aluminium landscape IP 65 luminaire for diffused lighting with high power LED as light souce housing made up of aluminium pipe UV protected pure polyester powder coated black after phosphochromate treatment it consists of aluminum heat sink for effective thermal management , sturdiness & excellent corrosion resistant mounting flange of MS sand casting is used at bottom PC diffuser in opal finish is used for glare free uniform light distribution powered by built in , isolated , potted electronic LED driver in ABS housing with APFC (SMPS based constant current supply) with lower THD , output short/open circuit protection , over voltage protection , Surge voltage protection Lumen efficiency not less than 110 lumen per watt system efficency ,power factor >0.95, THD<10% at Full load CRI> 70%
Supply and fixing in replacement 60 W LED street light fitting with mandatory driver set having pressure die cast aluminium housing with high efficiency LEDs as lighting source and lens embaded PC cover /IP lens, street light should have IP 66 protection, impact resistance of IK 07 , Lumen efficiency of LED not less than 110 lumen per watt system efficency ,power factor >0.95, THD<10% at Full load CRI> 70% ,street light should have built in potted electronic LED driver with , lower THD, open circuit protection , over voltage protection , surge voltage protection , and provided with company LOGO ingraved on housing of the street light complete including taking down of old UNSV fittings all as specified and directed by Engr -in-Charge. Note :-The contractor should take approval of techincal specification of luminaries and driver from department before procurement .
Supply and fixing in replacement of 200 W LED flood fitting having epoxy powder coated die cast aluminium housing ADC12 in grey finish with elegantly designed heat sink for efficient thermal management , sturdiness & excellent corrosion resistant. PG9 gland is used for cable entry and provision for loopin -loopout , PC lens/IP lens with narrow /wide beam distribution and toughened glass fixed to housing with screws , flood light should have IP 66 protection and impact resistance of IK 07 , Lumen efficiency of LED not less than 120 lumen per watt system efficency ,power factor >0.95, THD<10% at Full load CRI> 70% ,flood light should have built in potted electronic LED driver with , lower THD, open circuit protection , over voltage protection , surge voltage protection , and provided with company LOGO ingraved on housing of the flood light complete including taking down of old UNSV fittings all as specified and directed by Engr -in-Charge. Note :-The contractor should take approval of techincal specification of luminaries and driver from department before procurement .
All as per item Ser No 68 above but 120 Watt & Lumen efficiency of LED not less than 110 lumen per watt system efficiency
All as per item Ser No 68 above but 100 Watt & Lumen efficiency of LED not less than 110 lumen per watt system efficiency
All as per item Ser No 68 above but 50 Watt & Lumen efficiency of LED not less than 100 lumen per watt system efficiency
Supply & fix in replacement electronic LED Driver suitable for LED flood light 50 Watt to 100 Watt of existing make and model, fixed in light fitting & connecting & testing complete.
Supply & fixing in replacement electronic LED Driver suitable for LED flood light 120 Watt to 150 Watt of existing make and model, fixed in light fitting & connecting & testing complete.
Supply & fixing in replacement electronic LED Driver suitable for LED flood light 200 Watt of existing make and model, fixed in light fitting & connecting & testing complete.
Supply & fixing in replacement electronic LED Driver suitable for LED Street light fittings 45 Watt to 70 Watt of existing make and model, fixed in light fitting & connecting & testing complete.
Supply & fixing in replacement electronic LED Driver suitable for LED Street light fittings 90 Watt to 100 Watt of existing make and model, fixed in light fitting & connecting & testing complete.
Supply and errection in replacement 07 mtr continuously tapered hot dip galvanised Octagonal cross sectional pole with single dipping method having bottom 130 mm A/F and top 70 mm A/F 3 mm thick confirming to ASTM A 572 Gr with yield 450 mpa cut and folded to form an octagonal section and welded in accordance with AWS for wind loading as per IS 875 part 3 1987.Poles shall be provided with base plate of size 225x225x12 mm which shall be free from any lamination or incursion with no cutting or welding on the pole after hot dip galvanising with single arm 1000 mm long bracket tilted to 150 degree from horizontal toward vertices suitable for mounting on the octagonal pole, of company recommendation and one no TPN Connecton 3 phase 4 wire 100 Amps, and one number MCB SP 6 Amps. A triangular flat MS plat of 6mm thick duly coated with GI shall be welded between cap of the octagonal pole and bracket. Welding work shall be done 250mm on bracket and 150 mm on pole's cap including all RCC work type (1:2:4) type B-1 including 04 Nos foundation nut bolt and plate as per pole manufacturer's drawing and earth work all as per requirement complete all as specified and directed. Note Cost of construction of RCC foundation including construction material, necessary earth work and excavaton as per manufacturer design for above pole complete all as required at site and as directed by Engr-in-charge are deemed to be included in the quoted rate.
Supply & fixing in replacement automatic street light timer panel 5 KW switch using Infrared Sensor based for automatic switching of street lights based on LUX level of natural light. Required illuminance for switching ON is < 30 Lux and for switching OFF > 10 Lux level. The sensor (nature switch) alongwith suitable power contactors, Input (supply) MCB and output (load) MCB(s), support terminals should be enclosed in pole/ wall mountable enclosure made of rust proof, electric shock proof, termite proof and FR graded SMC junction box conforming to IP-54 degree of protection including mounting bracket, cable glands, openable doors with lock complete all as specified & directed by Engr-in-Charge.
Supplying, transporting, erecting in replacement Steel tubular swaged poles type 410 SP-31 ( 9.0 metres long) complete with cast iron base plate, finial, taper plug, bolts, nuts and screws as specified, including necessary excavation and earth work , PCC 1:4:8 type D2 in foundations below pole, PCC 1:3:6 type C2 around poles and PCC 1:3:6 type C1 as in plinth block , disposal of surplus soil to a distance not exceeding 50 m and depositing where directed, the exposed surface of steel tubular poles shall be painted with two coat of aluminum paint over a coat of red oxide, embaded portion of the pole shall be painted with one coat of bituminous paint. 05 Nos black and Yellow alternate strip with two coat of synthetic enamel paint shall be painted up to the the height of 1.5 M from copping of the pole including numbering on pole in black colour synthetic enamel paint complete all as specified and directed.
Supplying and fixing in replacement 3 pole power contractor AC 3 rating 40 Amp, 240 Volt AC complete all as specified and directed by Engr-in charge
Supplying and fixing in replacement 3 pole power contractor AC 3 rating 70 Amp, 240 Volt AC complete complete all as specified and directed by Engr-in charge
Supplying and fixing in replacement Astronomical Digital Timer Switch 240 V AC complete all as specified and directed by Engr-in charge
S&F in replacement post made of 50 mm dia GI Pipe (medium grade with necessary accessories and overall powder coated complete all as specified and directed. Note Post hole & PCC in foundation shall be measured and paid in respective item of schedule.
Material and labour for PCC 1:2:4 type B1 using 20 mm graded stone aggregates for making of foundation of post of oudoor luminaries complete all as specified and as directed by Engineer-in-Charge.
Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning,filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm,
Ajanta Associates
MTR GROUP & COMPANY
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .