Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹38.4 LAccepted-AOC A 102 GOLDEN SAND APARTMENTS GAZIPUR DHAKOLI ZIRAKPUR PB 160104 | ZIRAKPUR | S A S NAGAR | PUNJAB | 160104 | L1 | Accepted-AOC BEING L1 | |
| 2 | L2₹39.3 L+₹88,250 (2.30%)Rejected-Finance | L2 | Rejected-Finance BEING L2 | |
| 3 | L3₹39.5 L+₹1.1 L (2.93%)Rejected-Finance | L3 | Rejected-Finance BEING L3 | |
| 4 | L4₹46.4 L+₹8.0 L (20.9%)Rejected-Finance H NO 1366 3 GALI NO 6 MATA ROAD NEAR HAPPY MODEL SCHOOL RAJIV NAGAR GURGAON 122 001 HARYANA | GURGAON | GURGAON | HARYANA | 122001 | L4 | Rejected-Finance BEING L4 | |
| 5 | Rejected-Technical MEGHA SADAN GAGANNAGAR CURTI PONDA GOA 403401 | PONDA | SOUTH GOA | GOA | 403401 | - | Rejected-Technical No remark shown in WLR CE JZ Dec 2023 |
Tender Value
₹48 L
EMD Value
₹96,000
Closing Date
3 Jun 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Commander Works Engineer Hisar
Headquarters Commander Works Engineer Military Engineer Services Hisar, Military Station Hisar Hisar (Haryana)-125006
RESURFACING OF ROADS, EBS, BHOJRAJ AND CHANNIBARI AT HISAR MIL STN UNDER GE (WEST) HISAR
2024_MES_651841_1
CA NO CWE/HSR/12 OF 2024-25
Open Tender
Civil Works - Roads
Item Rate
180 days
Hisar
As per Notice Inviting Tender (NIT)
7 documents required · 7 mandatory
₹500
Yes
GE (West) Hisar
₹96,000
Yes
25 Jun 2024
1 May 2024
5 Jun 2024
1 May 2024
3 Jun 2024
20 May 2024
1 May 2024 - 22 May 2024
Amount
Repair to potholes any depth, not exceeding 1 sqm each including sweeping free from dust and mud, or water, scoring sunken surfaces in roads, paths, etc., cutting around edges to at least 25 mm in depth, making good by applying tack coat with cationic bitumen emulsion RS-1 grade at the rate of 5 kg per 10 sqm, putting in semi dense bituminous concrete (compacted thickness) using hot mix plant and mechanical paver using graded crushed stone aggregate premixed with binder (paving grade bitumen VG-30 grade) @ 5% by weight of total mix & hydraulic lime filler, rolled and compacted to required camber and gradient complete all as specified and as directed. Note :- (i) Semi dense bituminous concrete shall be laid using self propelled hydrostatic paver finisher and preparation of mix shall be using hot mix plant and transporting the mix in tipper. (ii) The exact bitumen content required shall be determined following the Marshall Mix Design procedure contained in the Asphalt Institute Manual MS-2 (Sixth Edition) as referred in case 3.5.3 of IRC 111: 2009. The adjustment in rate due to variation in quantity of bitumen if any shall be priced at the rate of ₹44 per kg.
Preparing existing black top surfaces by mechanical broom and high-pressure air jet or by other means as directed for removing dust, dirt, any extraneous materials, all loose materials, other foreign material etc. complete all as specified and as directed.
M & L for applying tack coat on existing bituminous, cement concrete or primed granular surface to ensure a bond between the surface being paved and the overlaying course with cationic bitumen emulsion RS-1 grade at the rate of 5 kg per 10 sqm of surface complete all as specified and as directed.
M & L for semi dense bituminous concrete 30 mm (compacted thickness) using graded crushed stone aggregate premixed with binder (paving grade bitumen VG-30 grade) @ 5% by weight of total mix & hydraulic lime filler, rolled and compacted to required camber and gradient complete all as specified and as directed. Note :- (i) Semi dense bituminous concrete shall be laid using self propelled hydrostatic paver finisher and preparation of mix shall be using hot mix plant and transporting the mix in tipper. (ii) The exact bitumen content required shall be determined following the Marshall Mix Design procedure contained in the Asphalt Institute Manual MS-2 (Sixth Edition) as referred in case 3.5.3 of IRC 111: 2009. The adjustment in rate due to variation in quantity of bitumen if any shall be priced at the rate of ₹44 per kg.
Providing and applying 2.5 mm thick road marking strips (retro-reflective) of specified shade/ colour using hot thermoplastic material by fully/ semi-automatic thermoplastic paint applicator machine fitted with profile shoe, glass beads dispenser, propane tank heater and profile shoe heater, driven by experienced operator on road surface including cost of material, labour, T & P, cleaning the road surface of all dirt, seals, oil, grease and foreign material etc. complete all as specified and as directed.
Supply and fix in repairs Glow studs (cat's eye) of size 80 to 100 mm X 80 to 100 mm X 15 to 20 mm made of heavy duty body shall be moulded ASA (Acrylic styrene Acryloretrite) or HIP (High impact polystyrene) or ABS having electronically welded micro- prismatic lens with abrasion resistant coating as approved by Engineer in charge. The cat’s eye shall support a load of 13635 kg tested in accordance with ASTM D4280. The slope of retro- reflective surface shall be 35⁰ ± 5⁰ to base. The reflective panels on both sides with at least 12 cm of reflective area up each side. The luminance intensity should be as per the specification and shall be tested as described in ASTM I: 809 as recommended in BS: 873 Part 4: 1973. The studs shall be fixed to the Road surface using the adhesive conforming to IS, as per procedure recommended by the manufacturer complete and as per direction of Engineer-in-charge.
S & F in repairs solar road studs of size not less than 125 mm X 125 mm X 25 mm made of weather resistance aluminium alloy and poly carbonate material electronically welded micro- prismatic lens with abrasion resistant coating as approved by the Engineer in charge. The cats eye shall support a load of 13635 kg tested in accordance with ASTM D4280. The slope of retro- reflective surface shall be 35⁰ ± 5⁰ to base. The reflective panels on both sides with at least 12 cm of reflective area up each side. The luminance intensity should be as per the specification and shall be tested as described in ASTM E: 809 as recommended in BS: 873 part 4 : 1973. The studs shall be fixed to the Road surface using the adhesive conforming to IS, as per procedure recommended by the manufacturer complete and as per direction of Engineer-in-charge. The solar panel shall be high efficiency mono crystalline 2.5 V/60 m A and the battery shall be one Ni-mh type (1.2 V/1200 m Ah) high temp for backup of 36 hours full charging. The flash frequency shall be 60 ± 5 times per minute.
malik constructions
M/S Sulakh Brothers
PAWAN KUMAR
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .