Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1098.2 CrAdmitted-Finance 139 2 SECOND FLOOR KODAMBAKKAM HIGH ROAD NUNGAMBAKKAM CHENNAI 600 034 | ₹1098.2 Cr | L1 | Admitted-Finance |
| 2 | L2₹1110 CrAdmitted-Finance DEE VEE HOUSE MAULSHREE VIHAR IN FRONT OF HOTEL BABYLON INTERNATIONAL VIP ROAD RAIPUR 492006 CHHATTISGARH | ₹1110 Cr | L2 | Admitted-Finance |
| 3 | L3₹1140.6 CrAdmitted-Finance | ₹1140.6 Cr | L3 | Admitted-Finance |
| 4 | L4₹1141.6 CrAdmitted-Finance PLOT NO 65 SECTOR 18 OPP HIPA SARHAUL GURUGRAM 122 001 | ₹1141.6 Cr | L4 | Admitted-Finance |
| 5 | L5₹1171.6 CrAdmitted-Finance KPC ONE 6 3 347 9 2 DWARAKAPURI COLONY PUNJAGUTTA HYDERABAD 500082 | ₹1171.6 Cr | L5 | Admitted-Finance |
| Sl No | Description | Qty | Unit | Varindera Constructions Limited L4 | KMV PROJECTS LIMITED L3 | URC Construction (P) Ltd L6 | KEC International Ltd L7 | Renaatus Projects Private Limited L1 | DEE VEE PROJECTS LIMITED L2 | KPC PROJECTS LIMITED L5 |
|---|---|---|---|---|---|---|---|---|---|---|
| 0.00ABSTRACT OF COST | ||||||||||
| 1.00 | PART - I : CIVIL WORKS | 1 | Nos | 2,30,15,58,632.51 ₹230.2 Cr | 2,61,71,60,479 ₹261.7 Cr | 3,03,53,39,017.8 ₹303.5 Cr | 2,84,82,93,009 ₹284.8 Cr | 2,47,72,18,627.6 ₹247.7 Cr | 2,49,89,67,110 ₹249.9 Cr | 2,46,06,14,229.2 ₹246.1 Cr |
| 2.00 | PART - II : PUBLIC HEALTH ENGINEERING WORKS | 1 | Nos | 24,67,88,261.18 ₹24.7 Cr | 24,47,04,505 ₹24.5 Cr | 24,70,78,796 ₹24.7 Cr | 33,12,57,960 ₹33.1 Cr | 18,98,20,012 ₹19.0 Cr | 17,69,35,560 ₹17.7 Cr | 21,30,21,932 ₹21.3 Cr |
| 3.00 | PART - III : ELECTRICAL WORKS | 1 | Nos | 67,89,08,314.3 ₹67.9 Cr | 50,22,31,022.5 ₹50.2 Cr | 52,48,02,801.5 ₹52.5 Cr | 65,03,89,737.5 ₹65.0 Cr | 52,76,60,659 ₹52.8 Cr | 55,63,82,070 ₹55.6 Cr | 67,48,95,337 ₹67.5 Cr |
| 4.00 | PART - IV : MECHANICAL WORKS | 1 | Nos | 53,79,66,906.06 ₹53.8 Cr | 38,62,80,539.1 ₹38.6 Cr | 42,83,07,736.4 ₹42.8 Cr | 52,61,87,040.5 ₹52.6 Cr | 42,93,51,606.2 ₹42.9 Cr | 43,56,68,310 ₹43.6 Cr | 50,60,72,921.7 ₹50.6 Cr |
| 5.00 | PART - V : STP & ETP WORKS | 1 | Nos | 4,02,17,255.74 ₹4.0 Cr | 5,14,77,055 ₹5.1 Cr | 6,09,45,649 ₹6.1 Cr | 4,50,71,926 ₹4.5 Cr | 3,65,80,998 ₹3.7 Cr | 3,20,46,950 ₹3.2 Cr | 5,07,32,137 ₹5.1 Cr |
Tender Value
₹350 Cr
EMD Value
₹3.6 Cr
Closing Date
1 Oct 2024, 5:00 pmClosed
Chief Engineer C1/CQD
DCSEM, DAE, 3rd floor, V.S. Bhavan, Anushaktinagar, Mumbai-94
Construction of Academic cum Residential complex along with other infrastructural facilities for Tata Institute of Fundamental Research, Hyderabad TIFRH at Hyderabad, Telangana, India.
2024_DCSEM_818572_1
QSA/RFP/TIFR-H/24-25/NIT/18 dt.26.07.2024
Limited
Civil Works
900 days
Hyderabad
Please refer Tender documents.
6 documents required · 6 mandatory
₹0
₹3.6 Cr
TIFR,Serilingampally,Hyderabad
16 Oct 2024
27 Jul 2024
7 Oct 2024
29 Jul 2024
1 Oct 2024
27 Aug 2024
29 Jul 2024 - 9 Aug 2024
13 Aug 2024
Amount
ABSTRACT OF COST
PART - I : CIVIL WORKS
PART - II : PUBLIC HEALTH ENGINEERING WORKS
PART - III : ELECTRICAL WORKS
PART - IV : MECHANICAL WORKS
PART - V : STP & ETP WORKS
Description of Work / Item(s)
Amount
ABSTRACT FOR PART - V : STP & ETP WORKS.
PART - V-A : 115 KLD STP AT PLOT-A
PART - V-B : 55 KLD STP AT PLOT-B
PART - V-C : 50 KLD ETP AT PLOT-A
Description of Work / Item(s)
Amount
PART - V : STP & ETP WORKS.
Part-V-A: 115 KLD STP at Plot-A
PART - A : MECHANICAL & ASSOCIATED WORKS FOR STP PLANT NOTES : The following items shall be considered in the scope of works for Design,supply, installation, testing & commissioning (SITC) of hgSBR STP & assocaited works for items covered under PART-A of this SOQ. The rates shall be all inclusive including all taxes & duties and Deptt. Will not pay any extra amount under any account. i) Electrical motors : All rotating mechanical equipments of STP like pumps/ blowers/ centrifuge/agitators/ centrifuge/dosing system etc., whether specifically indicated in the respective item or not, shall be equipped with high efficiency electrical motor IE2/ IE3 , suitably rated, squirrel cage induction motor, continuous duty with suitable synchronous speed (@3000/ 1500/1000 rpm) , class 'F' insulation, IP-55 degree of protection, rated to operate at 415 V +/- 10%, 50 Hz +/- 3%, 3 phase, AC supply, etc. as per requirement.
ii) Base frame & accessories: MS common base frame for installation of equipment's alongwith foundation bolts, flexible lovejoy/ flange/ bush coupling, coupling guard, anti vibration pads, standard fittings, flanges, other accessories etc. complete as per specification, drawings and instruction of Engineer-In-Charge (E.I.C.) iii) Mansoon Protection: Canopy made out of 20 SWG thick FRP sheet to protect the equipmets from monsoon, if equipment's are exposed to open area.
v) Foundations for Pumpsets & Equipment:- Providing Design-Mix rainforcement Cement Concrete Foundation for various pumps, blowers & other mechanical equipment of STP of M-30 by weight batching using graded stone aggregate of 20 mm maximum size including mechanical mixing & vibration, consolidation, finishing, curing etc. as specified and also including dewatering , if any , cost of form work, shuttering & steeel reinforcement, including nosing all around by 50 x 50 x 5 mm angle etc, all complere as per specification and as directed by EIC. vi) Supports for piping & header : Providing PCC supports for pipe supports/ headers of suitable size with cement morter 1:2:4 etc,all complere as per specification and as directed by EIC.
vii) Providing & fixing in position structural steel of angle, flats, joists, channel, I Beam, plain / chequered plates for support to pipes, cable tray etc. above Ground level & other miscellaneous works etc., including cutting, fabricating, welding, erecting in position including supplying & fixing embedded parts for fixing supports in concrete etc. complete as per specification and as directed by the E.I.C for STP plant. Any other works which are not included in schedule of quantities, scope of works but are required/ necessary for succesful commissioning & operation of Sewage Treatment Plant included in the scope of contractor. Deptt. Will not pay any extra amount under any account.
HYBRID GRANULAR SEQUENCING BATCH REACTOR SEWAGE TREATMENT PLANT (hgSBR STP)
SBR Bio-reactor unit configuration for hgSBR STP. Design, Supply, Installation, Testing, Commissioning of reactor for Hybrid Granular SBR (Sequencing Batch Reactor)) STP alongwith all its accessories, provision for sewage inlet & outlet flanges, sludge disposal connections, any other system requirement for Hybrid Granular SBR STP unit etc, all interconnecting piping within unit comprising of the following items and specification including any additional item required for the system and shall be as per proposed design of the agency and duly approved by the department. MOC: MS with epoxy paint (external) & 4mm thick FRP (internal) Shape: Cylindrical Orientation: Vertical Nos. of cycle/ day- 6 Reactor Volume- 36 m3 as per design proposed by agency and duly approved by the department
All associated piping, valves (manual/ Automaic), drain, bypass, overflow, pressure guages, re-circulation line etc. Supply, installation/ fixing in position structural steel of angle, flats, channel, I Beam, plain / chequered plates for providing frame including cutting, fabricating, welding, erecting in position etc. complete for installation of hgSTP tank MS Ladder, rungs, pathway with railing for accessing the SBR unit. 100/150 dia pipe fitting with outlet discharge using actuator / solenoid valve as per requirements.
Design (Electro-mechanical excluding Architectural & Structural), supply, installation, testing, commissioning including associated Electrical, Mechanical, Instrumentation & allied works for BARC Technology based Hybrid Granular Sequential Batch Reactor ( hgSBR) Sewage Treatment Plant . The STP shall comprise the following equipment and materials as per specification, drawings and accepted process of treatment, including cost of all materials, cost of labour, tools and plants and accessories to make plant operational. However, the actual components of hgSBR shall be based on proposed design of agency & duly approved by Department.
Bar Screen Manual Bar Screen and flow weir: Supply & installation of Bar screen and weir plate made of SS 304 of overall size 1000 x 500 mm and 500 x 500 mm shall be fabricated as per site condition and as directed by Engineer-In-charge (E.I.C. ) Note: coarse screen should be install before fine screen. Coarse bar screen: Fabricated by flats size 25 x 5 mm with spacing 10 mm and beeding at the edge, fitted with handle. Two guide rail fabrication in which bar screen will slide and fitted at the side wall of grit chamber as per instruction of Engineering - in - charge. Qty: 1 No. Fine bar screen: Made from Perforated plate of thickness 3.0 mm with Circular hole of dia < 5 mm and pitch 10.0 mm. It should have bedding at all the edges and one handle for handling. Two guide rail fabrication in which bar screen will slide and fitted at the side wall of grit chamber as per instruction of Engineering - in - charge. Qty: 1 No. Flow weir: Proportional type flow weir of size 500 x 500 mm with guide rail frame. Qty: 1 No.
Belt Type Oil Skimmer Design, supply, installation, testing, commissioning of belt type Motorised Oil Skimmer with suitable automatic oil removing mechanism for removing the floating oil from the influent suitable for 100 KLD STP for oil removal to achieve desired treated water parameters. MOC: MSEP Belt MOC: Oleophilic Polymer/ PU Motor: 0.5 HP (preferably geared motor), single phase or as per requirement Belt width: 100mm or as per requirement Collection tank of MSEP/FRP of suitable capacity. Qty: 1 No.
Raw Sewage pumps with electrical drive & associated works Supply, installation, testing and commissioning (SITC) of non-clog submersible pumpset at uniform flow rate equipped with suitable electrical drive & required associated works etc. Rating of Pumps : Flow 25 m3 / hr., Head : 15 mtr, solid handling capacty - 20 mm (max) MOC Pumps : Body C.I., Impeller C.I., Shaft SS / EN - 8, Mechanical seal, Motor as per requirement. The Piping MOC shall be CPVC, schedule - 80 and shall be as per proposed design of the agency and duly approved by the department. Qty: 2 Sets. ( 1 working + 1 stand by).
Piping for Air Distribution SBR tank, Equalisation Tank & Sludge Holding tank Design, providing, laying, testing & commissioning of air piping (SS 304) including fittings like elbows, tees, flanges, G.I. nut bolts with suitable support etc. complete as per the proposed design of agency and duly approved by the department. . Qty: 1 Lot
Air Blower for Reactor with electrical drive, DO control system & associated works Design, supply, installation, testing and commissioning of Twin Lobe/ Root air blower driven through “V” belt or directly coupled through flexible coupling & equipped with VFD enable motor drive & associated works including connection to air lines & fittings etc complete. Rating of Blowers : Dicsharge capacity - 80-120 m3 / hr , differential pressure : 0.45- 0.65 kg/sq.cm., Body C.I., M.S. safeguard cover, VFD enable motor as per requirement. The final parameters shall be as per proposed design of the agency and duly approved by the department. Qty: 2 Sets ( 1 Working + 1 Standby). Note: DO shall be maintained in the aeration/ reactor tank in excess of 4 mg/l
DO Control System (Sensor with Controller): Supply, installation, testing & commissioning of Optical Dissolved Oxygen system to control SBR Airblower to maintain the DO level excess of 4 mg/L by Proportional control Sensor Specifications: Luminescent Optical Technology- Measuring Range: 0-20mg/L or 0-20ppm or 0%-200%. Wetted Body material: SS (316L). Accuracy: +/- 0.5%. Resolution: atleast 0.1mg/l or ppm. Max Pressure 5 Bar. Sensor Cable length: atleast 15 or as per site requirement. Make: Potence Controls or Equivalent and model: PCODO1/PCODO3 or Equivalent Controller Specifications: Proportional Type: Display: Backlit LCD Screen 4*5 Chracters; 5 Directional Keys. Power requirement: 110V AC/ 230V AC, Operating temp: 0-55Deg C. Analog output signal: 0/4-20 mA Isolated. Relays: Electromechanical SPST;6A; 250V AC Max. Controller type: Proportional. Enclosure: IP65. Enclosure mounting: Wall, Panel. Make Potence Controls or Equivalent, model: PC200 or Equivalent.
Air Blower for Equalisation tank , Sludge Holding tank & Air Scouring for media filter with electrical drive & associated works Design, Supply, installation, testing and commissioning of Twin Lobe/ Root air blower driven through “V” belt or directly coupled through flexible coupling & equipped with suitable electrical drive & required associated works including connection to air lines & fittings etc complete. Rating of Blowers : Discharge capacity :75- 100 m3 / hr , differential pressure : 0.45 - 0.8 kg/sq.cm. , Body C.I., M.S. safeguard cover, Motor as per requirement. The final parameters shall be as per proposed design of the agency and duly approved by the department. Qty: 1 Set. Hydrocyclone solid-liquid seperator - 2"/2.5"/ 3 " NB size, Rated flowrate - 20 m3/ hr all as per the proposed design of agency and duly approved by the department..Qty: 1 Set. Automatic disc filter - 1.5"/ 2 " size, Rated flowrate - 5-8 m3 / hr or as per requirement . Automatic backwash and flow direction control with the 2 way automatic valve at inlet and outlet.Qty: 1 Set all as per the proposed design of agency and duly approved by the department.
GFRP component - Fabrication, Supply, Erection and commisioning of Feed header - 2"/ 2.5"/3 " NB , Qty: 1 Set. & Drain Header - 3"/ 4 " NB, Qty: 1 Set all as per the proposed design of agency and duly approved by the department.
Dosing System & Pumps Dosing system: Supply, installation, testing and commissioning of online manual / adjustable automatic dosing pump. The pump shall be operated on 220 V single phase supply and shall be mounted directly on the top of the tank with necessary nozzles, valves, piping etc. complete along wth first charge of chemicals as required and as per following specification.
Sodium Hypochlorite ( NaoCl) Dosing system Pump Capacity: 0- 20 LPH Electronically actuated diaphragm type / Mechanically actuated diaphragm type / Hydraulic diaphragm type dosing pump Max. Working Pressure - 3.0 kg/sq cm Level Switch Magnetic float type to trip the pump at low level of tank Dosing tank : 1 no. of 500 Ltr capacity MOC: PP HP- 1 Head - suitable MOC: HDPE/PP Qty- 1 Set.
Poly Dewatering ( Poly Dosing) dosing system Pump Capacity: 0- 20 LPH Electronically actuated diaphragm type / Mechanically actuated diaphragm type / Hydraulic diaphragm type dosing pump Max. Working Pressure - 3.0 kg/sq cm Level Switch Magnetic float type to trip the pump at low level of tank Dosing tank : 1 no. of 500 Ltr capacity MOC: PP HP- 1 Head - suitable MOC: HDPE/PP Qty- 1 Set.
Agitator for Poly Dewatering Dosing system: Supply, installation, testing and commissioning of Agitator/ Stirrer (MOC: SS & RPM 100) . The agitator with suitable drive mechanism shall be operated on 220 V single phase supply and shall be mounted directly on the tank top with necessary valves, piping etc. complete. Type- Vertical mounted gear motor Power rating of motor - 1 HP or as suitable Suitable base frame assembly for installation Qty: 1 Set.
Design, supply, Installation and commisoning of filters with the process lines and associated valves etc and mounting on the floor with PCC/ RCC foundation.
Pressure Sand Filter (PSF) with associated works Design, Supply, installation and commissioning of vertical pressure sand filter (PSF)/ Multi-grade filter (MGF) with internal components, required accessories like piping, fittings, pressure guages, air vent valve, valves, flange connections, nozzles, mounting etc. with initial charge of Filter media as required. The design of filter & media shall be as per proposed by the agency and duly approved by the department for obtaining desired treated sewage parameters. Piping: Laterals constructed in MS/CPVC and all frontal piping works constructed in CPVC. Dia: 1000 mm HOS: 1875 mm Shell thick: 6 mm Dish thick: 6 mm MOC: MS- Epoxy Specific flow rate – filter - 10 m3/hr./m2 Specific flow rate – backwash - 20 m3/hr./m2 PSF shall be painted internally and externally with one coat of epoxy primer with two coats of anticorrosive epoxy paint of approved color. Multi Grade Filter (MGF) filled with different grade of media,
Multimedia consist of (sand + fine sand + and different size of garnet), bed depth equally distributed filter media in multiple layers, velocity across the filter 8.0 – 10.0 m/hr. max., for filtration up to 50 micron particle The filter shall be fitted with inlet distribution and bottom collecting system. Qty: 1 Set
Activated Carbon Filter (ACF) with associated works Design, Supply, installation and commissioning of activated carbon filter with with internal components, required accessories like piping, fittings, pressure guages, air vent valve, valves,flange connections, nozzles, mounting etc. with initial charge of filter media as required. The design of filter & media shall be as per proposed by the agency and duly approved by the department for obtaining desired treated sewage parameters.
Piping: Laterals constructed in MS/CPVC and all frontal piping works constructed in CPVC. Dia: 1000 mm HOS: 1875 mm Shell thick: 6 mm Dish thick: 6 mm MOC: MS- Epoxy Specific flow rate – filter - 10 m3/hr./m2 Specific flow rate – backwash - 20 m3/hr./m2 ACF shall be painted internally and externally with one coat of epoxy primer with two coats of anticorrosive epoxy paint of approved color. Activated carbon filter filled with activated charcoal media, Single layer of activated carbon supported by gravels and pebbles at bottom, coconut shell carbon, adsorption efficiency – up to 90%, chlorine, color and odor removal –85 to 90%, Filter bed shall withstand the maximum pressure drop encountered during the operation, without breakdown of filter media, Filter media shall be non-toxic and shall not impart color, odor or taste to the water. The filter shall be fitted with inlet distribution and bottom collecting system. Qty: 1 Set
Filter Feed Pump with electrical drive & associated works Supply, installation, testing and commissioning (SITC) of non-clog submersible pumpset at uniform flow rate equipped with suitable electrical drive & required associated works etc. Rating of Pumps : Flow 8 m3 / hr, Head : 30 mtr, MOC Pumps : Body C.I., Impeller C.I., Shaft SS / EN - 8, Mechanical seal, solid handling capacity - 8mm (max), Motor as per requirement. The Piping MOC shall be CPVC, schedule - 80 and shall be as per proposed design of the agency and duly approved by the department. Qty: 2 Sets. ( 1 working + 1 stand by)
Backwash Pumpset with electrical drive & associated works Supply, installation, testing and commissioning (SITC) of non-clog Centrifugal Non submersible vertically mounted, flooded positive suction backwash pumpset at uniform flow rate equipped with suitable electrical drive & required associated works etc. Rating of Pumps : Flow - 20 m3 / hr., Head : 35 mtr, MOC Pumps : Body C.I., Impeller C.I., Shaft SS / EN - 8, Mechanical seal, solid handling capacity- 10 mm (max) , Motor as per requirement.. The Piping MOC shall be CPVC, schedule - 80 and shall be as per proposed design of the agency and duly approved by the department. Qty: 1 Set.
Backwash Tank: MOC: PP/ FRP Capacity: 7500 ltr liquid: clear water Mounting: Horizontal/ vertical cylindrical tank Sevice area: STP- open atm Mounting base: Roof top/terrace – mounted on raised platform. Manhole: Minimum one manhole with the size of 500 mm. Manhole with door Opening: Minimum one opening at the base and one opening at the top with flat face
Sludge Transfer pump with electrical drive & associated works Supply, installation, testing and commissioning (SITC) of non-clog Centrifugal/ screw type Non submersible sludge transfer pumpset with solid handling capacity of up to 20 mm (max.) at uniform flow rate equipped with electrical drive & associated works etc. Rating of Pumps : Flow 2 - 3 m3 / hr., Head : 15 mtr, NPSH (A): 3.2 mtr, MOC Pumps : Body C.I., Impeller C.I., Shaft SS / EN - 8, seal- mechanical/ gland packing, Motor as per requirement and shall be as per proposed design of the agency and duly approved by the department. Qty: 1 Set.
Sludge Dewatering System Design, Supply, Installation, testing & commissioing of sludge dewatering system consisting of following items i.e. sludge feed pump & decanter centrifuge
Sludge feed pump to Centrifuge with electrical drive & associated works Supply, installation, testing & commissioing of horizontal screw type/ Centrifugal type non clog, non submersible type with solid handling capacity of up to 20 mm (max.) at uniform flow rate equipped with electrical drive & associated works etc. Rating of Pumps : Flow 1- 2 m3 / hr., Head :15 - 40 mtr. MOC Pumps : Body C.I., Impeller C.I., Shaft SS / EN - 8, seal- mechanical/ gland packing, Motor as per requirement and shall be as per proposed design of the agency and duly approved by the department.. Qty: 1 set.
Centrifuge decanter with with electrical drive & associated works Supply, installation, testing & commissioing of sludge dewatering system consists of top discharge Verical type basket centrifuge with basket MOC- SS 304 & MS enclosure with suitable driven arrangement coupled with suitable capacity motor, etc. complete suitable for STP as per proposed design of the agency and duly approved by the department. Capacity: 3 m3/hr feed : 1- 2 m3 / hr Feed Solids: 1-4% Temperature @ 40 Deg C Outlet/ performance Parameters Cake solids : 15-20% Filtrate solid recovery: 90-95% Expected Polyelectrolyte dosage: 1-4 kg/ ton (actual usage will depend on jar test result) UPVC drain pipeline connection of suitable dia for disposal of liquid sludge into bar screen chamber as directed and instructed by E.I.C. Qty: 1 Set.
PLC operated Ultra Filtration (UF) System for STP Design, Supply, Installation, Testing & Commissioning of Ultra Filtration (UF) system suitable for hgSBR STP & to meet the desired parameters of treated sewage. The filtration efficiency of the membrane shall be to filter out virus & bacteria also in the range of ten to the power of minus 6 log reduction. The system shall be fully PLC based automatic plant for both filtration & backwash cycle. UV consisting of following items: PLC Panel: Design, factory testing, supply to site, instalation, testing and commisioning of PLC Panel, Plant autommation, cable laying, connections, fully wired with all required gadgets and relay boards for mounting PLC, Controller - 1 NO., Analog Input 4 Channel - 1 No., Digital Input 16 Channel - 6 No., Analog Output 2 Channel - 1 No., Digital Output 8 Channel - 6 No., HMI 7" (Parameter display/set-points/operations) - 1 No., Power Supply - 1 No., With full programming code writing, installation and testing executed at the site as per the process flow chart & associated instrumentation works includes various level transmitter, level switch, flowmeter, pressure gauge, quantity meter, control cables & signal cables etc. complete as per system requirement and shall be as per proposed design of the agency and duly approved by the department..
UF Feed Pumpset with Starter Panel & electro-mechanical accessories : Design, Supply, installation, testing and commissioning (SITC) of horizontal centrifugal non submersible, closed Impeller, self priming type at uniform flow rate equipped with suitable electrical drive & required associated works etc. like ball typefFootvalve (if required), NRV flap type/ ball type and delivery valve of butterfly type and pressure gauge (MOC-SS) glycerine filled with 4" dial and Rating of Pumps : Flow 8-10 m3 / hr., Head : 30 - 50 mtr , NPSH (A): 3.2 mtr, MOC Pumps : Body C.I., Impeller C.I., Shaft SS / EN - 8, Mech. Seal SS..Motor as required and shall be as per proposed design of the agency and duly approved by the department. Qty: 2 Sets ( 1 W + 1 S).
SITC of 14 SWG MS CRCA sheet starter enclosure, IP 55 wall mounting type, powder coated with approved shade complete with suitable automatic DOL / Star-delta starter with HRC back up protection (Type-II co-ordinated as per IS 13947-4-1) for UF feed pumpset with Working Standby Switch overload protection, current sensing type single phase preventor, internal wiring,manual/ auto operation complete with all accessories as per requirement. 1 No. water level control relay with 3 nos. stainless steel probes similar to M/s Minilec make cat no. WLC D1.The 3 Nos stainless steel probes with required lengths of PVC wires & multiple connectors shall be mounted as per site requirements. The scope also includes ammeter , CT, Indication lamps, contactors, On/Off push button as required, Note: Starter of both pumpset shall be accomodate in single starter box with all electrical accessories etc.
Ultrafiltration Membrane: Design, supply, installation, testing & commissioning of Hollow Fibres/ Tubular, MOC: Polyether Sulphone or as suitable, recovery rate > 85%, filter housing, MS skid etc. complete with all required accessories and also be able to tolerate Chlorine Dosing upto 25 ppm. Rating: 100000 mwco to achieve desired Treated Water Parameters and shall be as per proposed design of the agency and duly approved by the department. The membrane life shall be guaranteed for a period of 5 years of operation. Flow rate: 8 -10 m3/hr and shall be as per proposed design of the agency and duly approved by the department. Qty: 2 sets. ( 1 working + 1 stand by).
Design, supply, installation, testing & commissioning of CEB: NaOH & NaoCl, HCL Dosing systems with HDPE Dosing tanks& required accessories etc. complete. NaOH Dosing pump: MOC:PP, 15 [email protected] Kg/cm2, Qty: 2 Nos.(1W+1S), HCl Dosing Pump: MOC:PP,15 [email protected] Kg/cm2, Qty: 2 Nos.(1W+1S), NaoCl Dosing Pump: MOC:PP,15 [email protected] Kg/cm2, Qty: 2 Nos.(1W+1S) & HDPE Tank -200 Litres: 03Nos. Backflush Pumpsets: Design, supply, installation, testing and commissioning (SITC) of centrifugal non submersible, Self Priming type at uniform flow rate equipped with suitable electrical drive & required associated works etc. like ball type footvalve, NRV ball type and delivery valve of butterfly type with PN Rating of 1.0 min. and pressure gauge (MOC-S.S.) -glycerine filled with 4" Dial, backflush tank - 1no of required capacity , Rating of Pumps : Flow 15-20 m3 / hr @35 mtr, NPSH (A): 3.2 mtr, MOC Pumps : Body C.I., Impeller C.I., Shaft SS / EN - 8, Mech. Seal SS..Motor 10 HP or as per requirement and shall be as per proposed design of the agency and duly approved by the department.. Qty: 2 Sets ( 1 W + 1 S).
STP Plant piping, valves and associated works Entire hgSTP Plant piping including treated water pumpset , Instrumentation & associated works shall be considered in the scope of works for items covered under PART-A of this SOQ. Deptt. Will not pay any extra amount under any account. Note: Piping , cables & associated works for Submersible Sewage Pumps ( Item No. 6 of this SOQ /Part-a) shall be paid under relevant item of this SOQ.
Design, supply, installation, testing and commissioning of interconnecting piping of suitable dia CPVC Sch 80 / (aboveground/ underground) alongwith required fittings/ specials, pressure gauge, all required valves within the battery limit (Approx. 80m Length from the installed equipment of STP). The scope includes the suitable suction & discharge line, common header of required dia, associated piping & required valves, connections for drain, bypass, filter backwash, recirculation etc.complete all as per proposed design of agency and duly approved by the department for successful intallation of equipments/machinery's/plant & unit/ system operational. For Treated water pumpsets : MOC- GI , 'C' class, 3" dia pipeline (approx. 30 mtr length excluding battery limit ) from the installed treated water pumpsets for further connections as instructed by E.I.C.
Ozonator (Ozone Generating Equipment) Supply, installation, testing & commssioing of Ozonator (Ozone Generating Equipment) & Ozonator shall be able to produce 75 grams O3 / hr capacity alongwith ozone production chamber, frequency inverter, pannel assembly, ventury injector, booster pump, required valves, inlet & outlet line etc. complete with all required accessories as per requirement for succesful installation of Ozonator.
Ultravoilet Light Supply, installation, testing & commssioing (SITC) of UV system (Ultra Voilet Light) with Electrical ballast type electronic, reactor MOC- SS 316, UV dose- 600 J/m2, lamps ( 4 Nos) for disinfecton of sewage water. The work includes SITC of required piping, valves, connections, automatic quartz sleeve wiping system or self cleaning system, control panel, cables, MS powder coated control panel, all end connections, lamp replacement reminder, lamp failure indication with alarm, max. operating pressure - 120 psi, working on 220-240V / 50-60 Hz etc. complete with all necessary accessories with bypass arrangement as per requirement for succesful installation of UV system & shall be Compatible with hgSBR STP. Flow rate : 10 m3/hr @ 30 mtr head
Dewatering Pumps Supply, installation, testing & commissioning of Submersible dewatering Pump Set to give a discharge of 3 m3/hr and total head of 20 mtr with solid handling capacity upto 20 mm at uniform flow rate equipped with electrical drive, cable (50 mtr length )& associated works with PVC flexible hose pipe of 40 mm dia, with approx. 70 m length etc. complete in all respects as per site requirements and as directed by E-I-C.
Shed & Roofing Design, providing and fixing curved shaped roofing including facia etc with 'Galvalume' toughened permanently colour coated roofing sheet 0.5mm thick of M/s CRIL 'HISPAN' with special Polyester colour coating of 20 microns thickness(DFT) on exposed surfaces and 5 microns(DFT) on unexposed surfaces over 5 microns(DFT) of Polyester primer on both surfaces of CRCA sheet of 550Mpa with hot dip coating of 150 gms/ SqM Aluminium Zinc Alloy all as permanufacturers specifications of approved shade and colour, fixing to trusses at all levels including placing and fixing in position, bending to shape, cost of all materials, labour, tools and plants required for completion of work, all overlaps, metring wherever necessary,stainless steel anchor bolts, nuts, washers, making the roof leakproof all as permanufacturer's specification all etc. complete & shall be as per proposed design of the agency and duly approved by the department.
Submersible Sewage Sump Pumps (Plant Room Sump Drain Pumpset) Supply, installation, testing & commissioning of Submersible Non Clog, single stage, single entry pumps connected to TEFC submersible motor for 415 + 10% volts, 3 phase, 50 cycles A.C. power supply with mechanical seal, pump connector unit with rubber diaphragm and bend, vertical discharge pipe. The pump shall be provided with a lifting devise of pull chain/guide rail. (Pumps suitable to handle solids upto 20 mm size with C.I. body, SS304/EN8 shaft, CI impeller). Rating of Pumps : Flow - 10 m3 / hr., Head : 15 mtr, Mechanical seal, solid handling capacity- 20 mm, Motor as per requirement. Qty: 2 Sets. ( 1 working + 1 stand by- Cascade operation)
Panel mounted microprocessor based multi pump controller with large graphical display with VGA 240 x 320 pixels and IP 55 enclosure, diodes to indicate pump ready, earthing, pump running and fault condition, Cascade Operation. Each incomer and Outgoing feeder should be capable for protection against Overload, Short Circuit and Phase reversal condition and shall be capable to communicate with other controllers following. The PLC shall support MODBUS-IP communication for its compatability to intergrate with 3rd party BAS system. Controller shall authorise Read/Write command via BMS.All alarms should be displayed in the controller. System should be equipped with dry running protection. Indication of all type of faults / on-off status / electrical parameters shall be available on panel and central IBMS monitors. On-off operation for all pumps shall be available on BMS system.Scope shall also include supply, laying, termination of control and power cables of adequate size and arrangemnt of cable trayfrom pump to control panel etc. to complete the job. Electronic type low, Medium & High water level controller with LED panel to operate pump (necessary contacts along with minimum one PLC operated spare contacts required),level controller with operational mode as one pump working at Medium level, both pumps at High level with a hooter alarm and cut off at Low level complete the job.
Mounting Height (Low Level ): (Sump) Mounting Height (Medium Level) : (Sump) Mounting Height (Hight Level ): (Sump) with probe & all control wiring from Pump room Panel to Sump to operate the system automatic/manual & shall prevent the pump from dry running. Scope shall also includes supply, laying, testing & commissioning (underground/ aboveground/ floor) power and control cable of required size, termination, cable tray from Pump to Control panel, control cable as whereever required etc. complete the job. Scope shall also includes supply, laying, testing & commissioning (underground/ aboveground/ floor) of CPVC SCH 80, 3" NB pipeline (approx. 100 mtr length) with fittings/ specials to correct line, level and plumb, leak proof threaded / welded joints, all required valves of rating PN 10 like NRV, isolation valve, SV, pressure gauge discharge header, bypass arrangements to equalisation tank with all required valves etc. to completethe job as per site requirement & as directed by Engineer-In-Charge.
Treated water pumpset with electrical drive & associated works Supply, installation, testing and commissioning (SITC) of non-clog Centrifugal Non submersible Self Priming pumpsets at uniform flow rate equipped with suitable electrical drive with all associated works etc. and shall be as per proposed design of the agency and duly approved by the department. Pumpset shall be variable speed, in-line installation, Electronic type low water level controller with LED panel to operate pump (necessary contacts along with minimum one PLC operated spare contacts required), with probe & all control wiring from Panel to tank to operate the system automatic/manual & shall prevent the pump from dry running.
Operation of pumpsets shall be fully automatic by PLC:- The PLC shall support MODBUS-IP communication for its compatability to intergrate with 3rd party BAS system. Controller shall authorise Read/Write command via BMS.System should be capable to compensate for frictional losses at lower flows. All alarms should be displayed in the controller. System should be equipped with dry running protection. Indication of all type of faults / on-off status / electrical parameters shall be available on panel and central IBMS monitors. On-off operation for all pumps shall be available on BMS system etc. complete as per requirement.
Flushing water pumpset:- Rating of Pumps : Flow 6 m3 / hr., Head :70 mtr, NPSH (A) 3.2 mtr, MOC Pumps : Body C.I., Impeller C.I., Shaft SS/EN8, Solid handlind capacity upto 8 mm, Seal- Mechanical seal, Motor as per requirement. Qty- 3 sets (2 Working + 1 Standby - cascade operation).
Gardening/ Pond water pumpset:- Rating of Pumps : Flow 15 m3 / hr., Head :50 mtr, NPSH (A) 3.2 mtr, MOC Pumps : Body C.I., Impeller C.I., Shaft SS/EN8, Solid handlind capacity upto 8 mm, Seal- Mechanical seal, Motor as per requirement. Qty- 3 sets (2 Working + 1 Standby - cascade operation).
HVAC Makeup water pumpset:- Rating of Pumps : Flow 20 m3 / hr., Head :30 mtr, NPSH (A) 3.2 mtr, MOC Pumps : Body C.I., Impeller C.I., Shaft SS/EN8, Solid handlind capacity upto 8 mm, Seal- Mechanical seal, Motor as per requirement..Qty- 3 sets (2 Working + 1 Standby - cascade operation). Electronic type low, Medium & High water level controller with LED panel to operate pump (necessary contacts along with minimum one PLC operated spare contacts required),level controller with operational mode as one pump working at Medium level, both pumps at High level with a hooter alarm and cut off at Low level complete the job. -Mounting Height (Low Level ): (Sump), Mounting Height (Low Level ): (Sump), Mounting Height (Hight Level ): (Sump) with probe & all control wiring from Pump room Panel to Sump to operate the system automatic/manual & shall prevent the pump from dry running.
Road cutting & re-surfacing Cutting the existing asphalt road and demolishing WBM or BBM including rubble soling if any for providing services and making good the same after the work is satisfactorily completed, including relaying of soling doing water bound macadam, bituminous bound macadam road providing and laying 50 mm thick asphaltic layer etc, complete as directed by E-I-C.
TOTAL OF PART-A
PART-B: ELECTRICAL, INSTRUMENTATION, AUTOMATION & ASSOCIATED WORKS FOR STP PLANT
Supply, Instalation, testing and commisioning of electrical equipment: MCC panel, RVMCC panel, PLC Panel & associated instrumentation works.
Fabrication, factory testing, supply to site installation, testing and commissioning of process motor control centre (PMCC panel), cable laying, connection, testing and commissioning etc.
Fabrication, supply, installation and testing and commissioning of remote valve MCC (RVMCC), cable laying, connection, testing and commissioning of motorised remote valves and process motors.
Supply, instalation, testing and commisionin of Plant autommation and insrumentation PLC panel : Fully wired with all required gadgets and relay boards for mounting PLC, Controller - 1 NO., Analog Input 4 Channel or as required - 1 No., Digital Input 16 Channel - 6 No., Analog Output 2 Channel - 1 No., Digital Output 8 Channel - 6 No., HMI 7" (Parameter display/set-points/operations) - 1 No., Power Supply - 1 No., with full programming code writing, installation and testing executed at the site as per the process flow chart & all as per system requirement.
Supply and fixing of Level Transmitter - Ultrasonic Level Transmitter Supply and fixing of Flote type level Switch - Range 5.0 m Supply and instalation of Flowmeter Magnetic Flow Meter / Dial Gauge ventury flow meter - 80 NB Line ,Flow range - 0 - 50.0 m3/hr- 1 No Magnetic Flow Meter / Dial Gauge ventury flow meter - 65 NB Line , Flow range - 0 - 50.0 m3/hr- 2 Nos. Glass tube Rotameter - Flange type mounting , Flow range 0 - 50 m3/hr. Supply and instalation of quantity meter Quantity meter - 50 NB, indicator and transmitter - For Liquid, Flow range 0 - 50 m3 / hr. Quantity meter - 80 NB, indicator and transmitter - For Liquid, Flow range 0 - 50 m3 / hr. Supply and fixing of Dissolved Oxygen - DO Sensor With Controller, indicator and tranmitter, upto 3.0 m Depth
Supply and fixing of Differiatial Pressure Gauge - Differential Pressure Gauge Range : 0 – 1 kg/cm2 Pressure Gauges - Bourdon Sensing Pressure Gauge (glycerine filled) Range : 0-10Kg/cm2, It includes pipe fitting with vent valve and drain valve. Cables - Core cables and Signal cables: 1 Pair/2 Core or as required, 1 sq mm/1.5 sq mm Supply and installation of power socket boxes with 5 pin metal clad socket and plug top with 32a cat-c MCB of 4 pole, fixing against wall with suitable support Digital energy meter
Power Cables & Control Cables (FRLS) Supply, installation, testing & commissioning of 1.1 KV grade multicore copper soild/ stranded conductor ,HRPVC insulated, FRLS PVC sheated armoured power & control cable with suitable fixing arragement & accessories as per system requirement & as directed by Engineer-In-Charge (E.I.C.)
Cable Tray Supply & fixing ladder type GI cable trays with vertical sides on both ends and suitable MS supports i.e.channel, beam, angle including concrete bolts, hold fast etc. The scope includes supply of readymade bends, reducers,Tee, covers etc. as required as per instructions of EIC. Note : The scope of work also includes End jointing of above cables by crimping with supply of all jointing materials like solderless tinned copper cable socket, cable glands, gland earthing, insulation tape, flux, duplicate interconnection between gland earthing strip & to the nearest earthing bus terminals as per the drawings, specifications and as per the instructions of the Engineer-in-charge.
Earthing system Supply, installation, testing & commissioning of earthing system ( 2 sets) & associated accessories, etc. complete as per requirements & as per the instructions of E.I.C.
Note 1. Measurements of resistance of each earth station & resistance of complete scheme of earthing layout must be measured & recorded 2. Jointing of the earth strip shall be with brass nuts bolts and also with solder joints. 3. Jointing of the earth wire shall be with solder joints with tinned cable sockets GI earth plate electrode 600 x 600 x 6 mm earth station 2.5 m below ground level conforming to IS 3043 complete with all required materials like coke/charcoal, salt, brass nut-bolts & washers, watering arrangement, G.I pipe (B class) masonary chamber, min. 10mm thick chequered plate cover associated materials like 40 x 40 x 5mm angle iron frame work, hinges, locking arrangement etc. & excavation in all types of soil, refilling & removal of excess earth.
GI strip/wire fixed to wall/side of trench/ slab/column/beam/shaft with 5mm thick G.I spacers & GI saddles or on existing cable tray with saddles or in ground at 750 mm below including excavation in all types of soil with protective baked bricks, refilling & removal of excess earth within a radius of 500 m temporary reinstatement & back filling of trench, interconnections of earth strip/wire with brass nuts, bolts & washers and solder jointing, painting with two coats of black bituminous compound for earth wire/strip in ground & green enamel paint for earth wire/strip on surface , etc. MOC: 25 x 6 mm GI Strip & 8 SWG copper wire
TOTAL OF PART-B
PART - C - OPERATION & MAINTENANCE OF STP
Statutory approval for hgSBR plant Statutory approval/ Permission : Obtaining Statutory approval for above plant from local bodies/ Muncipal corporation, State bodies/ State pollution control board, MOEF and obtaining permissions & clearances for running the plant on regular basis.
Operation & Maintenance of hgSBR STP & Ultrafiltration (UF) plant Operation & Maintenance of plant : Operation & Maintenance of above plant for one year on 24 x 7 basis in three shift during defect liability period from the date of succesful commissioning & handing over the plant to the Department/ User including deployment of technical manpower (minimum 1 person per shift). The scope also includes the follwing Note 1: All chemicals required for period of one year including initial charge of chemicals. Note 2: Cost of all chemicals required for poly dosing system for period of one year including initial charge of chemicals. Note-3: Sodium Hypo Chloirde solution ( 5 to 10 % concentration of chlorine) for dis-infecton of treated sewage outlet from STP plant and Chlorine dosing system for period of one year including initial charge of chemicals. Note-4: Disposal of collected oil, grease, floating materials, grit should be disposed off at suitable location within radius of 2 KM at regular intervals as per instruction of E.I.C./ Department. Contractor has to make necessary arrangement at his own cost for disposal with necessary arrangement for transportation, manpower etc..
Testing Of Samples Testing samples & submiting the testing report to Department of raw sewage at bar screen/ Grit chamber chamber inlet ( 01 Sample) & treated effluent from STP ( 01 Sample) . Sample testing includes the parameters like PH, COD, BOD, TSS, Oil & grease, residual chlorine, fecal coliform, NH4-N, N-Total, Total Phosphorous as mention in Design Basis. Sample should be tested from approved lab like NABET Accredited, MOEF, SPCB or Govt. approved lab as per instruction and as directed by Engineer-In-charge (E.I.C.). Note: One sample for raw sewage & One sample for treated sewage will be count as a one set.
TOTAL OF PART-C
NET TOTAL of Part-V-A: 115 KLD STP at Plot-A
Part-V-B: 55 KLD STP at Plot-B
PART - A : MECHANICAL & ASSOCIATED WORKS FOR STP PLANT NOTES : The following items shall be considered in the scope of works for Design,supply, installation, testing & commissioning (SITC) of hgSBR STP & assocaited works for items covered under PART-A of this SOQ. The rates shall be all inclusive including all taxes & duties and Deptt. Will not pay any extra amount under any account. i) Electrical motors : All rotating mechanical equipments of STP like pumps/ blowers/ centrifuge/agitators/ centrifuge/dosing system etc., whether specifically indicated in the respective item or not, shall be equipped with high efficiency electrical motor IE2/ IE3 , suitably rated, squirrel cage induction motor, continuous duty with suitable synchronous speed (@3000/ 1500/1000 rpm) , class 'F' insulation, IP-55 degree of protection, rated to operate at 415 V +/- 10%, 50 Hz +/- 3%, 3 phase, AC supply, etc. as per requirement.
ii) Base frame & accessories: MS common base frame for installation of equipment's alongwith foundation bolts, flexible lovejoy/ flange/ bush coupling, coupling guard, anti vibration pads, standard fittings, flanges, other accessories etc. complete as per specification, drawings and instruction of Engineer-In-Charge (E.I.C.) iii) Mansoon Protection: Canopy made out of 20 SWG thick FRP sheet to protect the equipmets from monsoon, if equipment's are exposed to open area.
v) Foundations for Pumpsets & Equipment:- Providing Design-Mix rainforcement Cement Concrete Foundation for various pumps, blowers & other mechanical equipment of STP of M-30 by weight batching using graded stone aggregate of 20 mm maximum size including mechanical mixing & vibration, consolidation, finishing, curing etc. as specified and also including dewatering , if any , cost of form work, shuttering & steeel reinforcement, including nosing all around by 50 x 50 x 5 mm angle etc, all complere as per specification and as directed by EIC. vi) Supports for piping & header : Providing PCC supports for pipe supports/ headers of suitable size with cement morter 1:2:4 etc,all complere as per specification and as directed by EIC.
vii) Providing & fixing in position structural steel of angle, flats, joists, channel, I Beam, plain / chequered plates for support to pipes, cable tray etc. above Ground level & other miscellaneous works etc., including cutting, fabricating, welding, erecting in position including supplying & fixing embedded parts for fixing supports in concrete etc. complete as per specification and as directed by the E.I.C for STP plant. Any other works which are not included in schedule of quantities, scope of works but are required/ necessary for succesful commissioning & operation of Sewage Treatment Plant included in the scope of contractor. Deptt. Will not pay any extra amount under any account.
HYBRID GRANULAR SEQUENCING BATCH REACTOR SEWAGE TREATMENT PLANT (hgSBR STP)
SBR Bio-reactor unit configuration for hgSBR STP. Design, Supply, Installation, Testing, Commissioning of reactor for Hybrid Granular SBR (Sequencing Batch Reactor) STP alongwith all its accessories, provision for sewage inlet & outlet flanges, sludge disposal connections, any other system requirement for Hybrid Granular SBR STP unit etc, all interconnecting piping within unit comprising of the following items and specification including any additional item required for the system and shall be as per proposed design of the agency and duly approved by the department.
MOC: MS with epoxy paint (external) & 4mm thick FRP (internal) Shape: Cylindrical Orientation: Vertical Nos. of cycle/ day- 6 Reactor Volume- 18 m3 as per design proposed by agency and duly approved by the department All associated piping, valves (manual/ Automaic), drain, bypass, overflow, pressure guages, re-circulation line etc. Supply, installation/ fixing in position structural steel of angle, flats, channel, I Beam, plain / chequered plates for providing frame including cutting, fabricating, welding, erecting in position etc. complete for installation of hgSTP tank MS Ladder, rungs, pathway with railing for accessing the SBR unit. 100/150 dia pipe fitting with outlet discharge using actuator / solenoid valve as per requirements.
Design (Electro-mechanical excluding Architectural & Structural), supply, installation, testing, commissioning including associated Electrical, Mechanical, Instrumentation & allied works for BARC Technology based Hybrid Granular Sequential Batch Reactor ( hgSBR) Sewage Treatment Plant . The STP shall comprise the following equipment and materials as per specification, drawings and accepted process of treatment, including cost of all materials, cost of labour, tools and plants and accessories to make plant operational. However, the actual components of hgSBR shall be based on proposed design of agency & duly approved by Department.
Bar Screen Manual Bar Screen and flow weir: Supply & installation of Bar screen and weir plate made of SS 304 of overall size 1000 x 500 mm and 500 x 500 mm shall be fabricated as per site condition and as directed by Engineer-In-charge (E.I.C. ) Note: coarse screen should be install before fine screen. Coarse bar screen: Fabricated by flats size 25 x 5 mm with spacing 10 mm and beeding at the edge, fitted with handle. Two guide rail fabrication in which bar screen will slide and fitted at the side wall of grit chamber as per instruction of Engineering - in - charge. Qty: 1 No. Fine bar screen: Made from Perforated plate of thickness 3.0 mm with Circular hole of dia < 5 mm and pitch 10.0 mm. It should have bedding at all the edges and one handle for handling. Two guide rail fabrication in which bar screen will slide and fitted at the side wall of grit chamber as per instruction of Engineering - in - charge. Qty: 1 No. Flow weir: Proportional type flow weir of size 500 x 500 mm with guide rail frame. Qty: 1 No.
Belt Type Oil Skimmer Design, supply, installation, testing, commissioning of belt type Motorised Oil Skimmer with suitable automatic oil removing mechanism for removing the floating oil from the influent suitable for STP for oil removal to achieve desired treated water parameters. MOC: MSEP Belt MOC: Oleophilic Polymer/ PU Motor: 0.5 HP (preferably geared motor), single phase or as per requirement Belt width: 100mm or as per requirement Collection tank of MSEP/FRP of suitable capacity. Qty: 1 No.
Raw Sewage pumps with electrical drive & associated works Supply, installation, testing and commissioning (SITC) of non-clog submersible pumpset at uniform flow rate equipped with suitable electrical drive & required associated works etc. Rating of Pumps : Flow 12 m3 / hr., Head : 15 mtr, solid handling capacty - 20 mm (max) MOC Pumps : Body C.I., Impeller C.I., Shaft SS / EN - 8, Mechanical seal, Motor as per requirement. The Piping MOC shall be CPVC, schedule - 80 and shall be as per proposed design of the agency and duly approved by the department. Qty: 2 Sets. ( 1 working + 1 stand by).
Piping for Air Distribution SBR tank, Equalisation Tank & Sludge Holding tank Design, providing, laying, testing & commissioning of air piping (SS 304) including fittings like elbows, tees, flanges, G.I. nut bolts with suitable support etc. complete as per the proposed design of agency and duly approved by the department. . Qty: 1 Lot
Air Blower for Reactor with electrical drive, DO control system & associated works Design, supply, installation, testing and commissioning of Twin Lobe/ Root air blower driven through “V” belt or directly coupled through flexible coupling & equipped with VFD enable motor drive & associated works including connection to air lines & fittings etc complete. Rating of Blowers : Dicsharge capacity - 40-60 m3 / hr , differential pressure : 0.45- 0.65 kg/sq.cm., Body C.I., M.S. safeguard cover, VFD enable motor as per requirement. The final parameters shall be as per proposed design of the agency and duly approved by the department. Qty: 2 Sets ( 1 Working + 1 Standby). Note: DO shall be maintained in the aeration/ reactor tank in excess of 4 mg/l
DO Control System (Sensor with Controller): Supply, installation, testing & commissioning of Optical Dissolved Oxygen system to control SBR Airblower to maintain the DO level excess of 4 mg/L by Proportional control Sensor Specifications: Luminescent Optical Technology- Measuring Range: 0-20mg/L or 0-20ppm or 0%-200%. Wetted Body material: SS (316L). Accuracy: +/- 0.5%. Resolution: atleast 0.1mg/l or ppm. Max Pressure 5 Bar. Sensor Cable length: atleast 15 or as per site requirement. Make: Potence Controls or Equivalent and model: PCODO1/PCODO3 or Equivalent Controller Specifications: Proportional Type: Display: Backlit LCD Screen 4*5 Chracters; 5 Directional Keys. Power requirement: 110V AC/ 230V AC, Operating temp: 0-55Deg C. Analog output signal: 0/4-20 mA Isolated. Relays: Electromechanical SPST;6A; 250V AC Max. Controller type: Proportional. Enclosure: IP65. Enclosure mounting: Wall, Panel. Make Potence Controls or Equivalent, model: PC200 or Equivalent.
Air Blower for Equalisation tank , Sludge Holding tank & Air Scouring for media filter with electrical drive & associated works Design, Supply, installation, testing and commissioning of Twin Lobe/ Root air blower driven through “V” belt or directly coupled through flexible coupling & equipped with suitable electrical drive & required associated works including connection to air lines & fittings etc complete. Rating of Blowers : Discharge capacity :40- 50 m3 / hr , differential pressure : 0.45 - 0.8 kg/sq.cm. , Body C.I., M.S. safeguard cover, Motor as per requirement. The final parameters shall be as per proposed design of the agency and duly approved by the department. Qty: 1 Set.
Hydrocyclone solid-liquid seperator - 2"/2.5"/ 3 " NB size, Rated flowrate - 20 m3/ hr all as per the proposed design of agency and duly approved by the department..Qty: 1 Set. Automatic disc filter - 1.5"/ 2 " size, Rated flowrate - 5-8 m3 / hr or as per requirement . Automatic backwash and flow direction control with the 2 way automatic valve at inlet and outlet.Qty: 1 Set all as per the proposed design of agency and duly approved by the department. GFRP component - Fabrication, Supply, Erection and commisioning of Feed header - 2"/ 2.5"/3 " NB , Qty: 1 Set. & Drain Header - 3"/ 4 " NB, Qty: 1 Set all as per the proposed design of agency and duly approved by the department.
Dosing System & Pumps Dosing system: Supply, installation, testing and commissioning of online manual / adjustable automatic dosing pump. The pump shall be operated on 220 V single phase supply and shall be mounted directly on the top of the tank with necessary nozzles, valves, piping etc. complete along wth first charge of chemicals as required and as per following specification.
Sodium Hypochlorite ( NaoCl) Dosing system Pump Capacity: 0- 10 LPH Electronically actuated diaphragm type / Mechanically actuated diaphragm type / Hydraulic diaphragm type dosing pump Max. Working Pressure - 3.0 kg/sq cm Level Switch Magnetic float type to trip the pump at low level of tank Dosing tank : 1 no. of 500 Ltr capacity MOC: PP HP- 1 Head - suitable MOC: HDPE/PP Qty- 1 Set.
Poly Dewatering ( Poly Dosing) dosing system Pump Capacity: 0- 20 LPH Electronically actuated diaphragm type / Mechanically actuated diaphragm type / Hydraulic diaphragm type dosing pump Max. Working Pressure - 3.0 kg/sq cm Level Switch Magnetic float type to trip the pump at low level of tank Dosing tank : 1 no. of 500 Ltr capacity MOC: PP HP- 1 Head - suitable MOC: HDPE/PP Qty- 1 Set.
Agitator for Poly Dewatering Dosing system: Supply, installation, testing and commissioning of Agitator/ Stirrer (MOC: SS & RPM 100) . The agitator with suitable drive mechanism shall be operated on 220 V single phase supply and shall be mounted directly on the tank top with necessary valves, piping etc. complete. Type- Vertical mounted gear motor Power rating of motor - 1 HP or as suitable Suitable base frame assembly for installation Qty: 1 Set.
Design, supply, Installation and commisoning of filters with the process lines and associated valves etc and mounting on the floor with PCC/ RCC foundation.
Pressure Sand Filter (PSF) with associated works Design, Supply, installation and commissioning of vertical pressure sand filter (PSF)/ Multi-grade filter (MGF) with internal components, required accessories like piping, fittings, pressure guages, air vent valve, valves, flange connections, nozzles, mounting etc. with initial charge of Filter media as required. The design of filter & media shall be as per proposed by the agency and duly approved by the department for obtaining desired treated sewage parameters.
Piping: Laterals constructed in MS/CPVC and all frontal piping works constructed in CPVC. Dia: 800 mm HOS: 1600 mm Shell thick: 6 mm Dish thick: 6 mm MOC: MS- Epoxy Specific flow rate – filter - 5 m3/hr./m2 Specific flow rate – backwash - 10 m3/hr./m2 PSF shall be painted internally and externally with one coat of epoxy primer with two coats of anticorrosive epoxy paint of approved color. Multi Grade Filter (MGF) filled with different grade of media, Multimedia consist of (sand + fine sand + and different size of garnet), bed depth equally distributed filter media in multiple layers, velocity across the filter 8.0 – 10.0 m/hr. max., for filtration up to 50 micron particle The filter shall be fitted with inlet distribution and bottom collecting system. Qty: 1 Set
Activated Carbon Filter (ACF) with associated works Design, Supply, installation and commissioning of activated carbon filter with with internal components, required accessories like piping, fittings, pressure guages, air vent valve, valves,flange connections, nozzles, mounting etc. with initial charge of filter media as required. The design of filter & media shall be as per proposed by the agency and duly approved by the department for obtaining desired treated sewage parameters.
Piping: Laterals constructed in MS/CPVC and all frontal piping works constructed in CPVC. Dia: 800 mm HOS: 1600 mm Shell thick: 6 mm Dish thick: 6 mm MOC: MS- Epoxy Specific flow rate – filter - 5 m3/hr./m2 Specific flow rate – backwash - 10 m3/hr./m2 ACF shall be painted internally and externally with one coat of epoxy primer with two coats of anticorrosive epoxy paint of approved color. Activated carbon filter filled with activated charcoal media, Single layer of activated carbon supported by gravels and pebbles at bottom, coconut shell carbon, adsorption efficiency – up to 90%, chlorine, color and odor removal –85 to 90%, Filter bed shall withstand the maximum pressure drop encountered during the operation, without breakdown of filter media, Filter media shall be non-toxic and shall not impart color, odor or taste to the water. The filter shall be fitted with inlet distribution and bottom collecting system. Qty: 1 Set
Filter Feed Pump with electrical drive & associated works Supply, installation, testing and commissioning (SITC) of non-clog submersible pumpset at uniform flow rate equipped with suitable electrical drive & required associated works etc. Rating of Pumps : Flow 4 m3 / hr, Head : 30 mtr, MOC Pumps : Body C.I., Impeller C.I., Shaft SS / EN - 8, Mechanical seal, solid handling capacity - 8mm (max), Motor as per requirement. The Piping MOC shall be CPVC, schedule - 80 and shall be as per proposed design of the agency and duly approved by the department. Qty: 2 Sets. ( 1 working + 1 stand by)
Backwash Pumpset with electrical drive & associated works Supply, installation, testing and commissioning (SITC) of non-clog Centrifugal Non submersible, flooded positive suction backwash pumpset at uniform flow rate equipped with suitable electrical drive & required associated works etc. Rating of Pumps : Flow - 10 m3 / hr., Head : 35 mtr, MOC Pumps : Body C.I., Impeller C.I., Shaft SS / EN - 8, Mechanical seal, solid handling capacity- 10 mm (max) , Motor as per requirement.. The Piping MOC shall be CPVC, schedule - 80 and shall be as per proposed design of the agency and duly approved by the department. Qty: 1 Set.
Backwash Tank: MOC: PP/ FRP Capacity: 5000 ltr liquid: clear water Mounting: Horizontal/ vertical cylindrical tank Sevice area: STP- open atm Mounting base: Roof top/terrace – mounted on raised platform. Manhole: Minimum one manhole with the size of 500 mm. Manhole with door Opening: Minimum one opening at the base and one opening at the top with flat face
Sludge Transfer pump with electrical drive & associated works Supply, installation, testing and commissioning (SITC) of non-clog Centrifugal/ screw type Non submersible, flooded positive suction sludge transfer pumpset with solid handling capacity of up to 20 mm (max.) at uniform flow rate equipped with electrical drive & associated works etc. Rating of Pumps : Flow 1 - 2 m3 / hr., Head : 15 mtr, NPSH (A): 3.2 mtr, MOC Pumps : Body C.I., Impeller C.I., Shaft SS / EN - 8, seal- mechanical/ gland packing, Motor as per requirement and shall be as per proposed design of the agency and duly approved by the department. Qty: 1 Set.
Sludge Dewatering System Design, Supply, Installation, testing & commissioing of sludge dewatering system consisting of following items i.e. sludge feed pump & decanter centrifuge
Sludge feed pump to Centrifuge with electrical drive & associated works Supply, installation, testing & commissioing of horizontal Centrifugal type non clog, non submersible type with solid handling capacity of up to 20 mm (max.) at uniform flow rate equipped with electrical drive & associated works etc. Rating of Pumps : Flow 1- 2 m3 / hr., Head :15 - 40 mtr. MOC Pumps : Body C.I., Impeller C.I., Shaft SS / EN - 8, seal- mechanical/ gland packing, Motor as per requirement. Qty: 1 set.
Centrifuge decanter with with electrical drive & associated works Supply, installation, testing & commissioing of sludge dewatering system consists of top discharge Verical type basket centrifuge with basket MOC- SS 304 & MS enclosure with suitable driven arrangement coupled with suitable capacity motor, etc. complete suitable for STP as per proposed design of the agency and duly approved by the department. Capacity: 2 m3/hr feed : 1- 2 m3 / hr Feed Solids: 1-4% Temperature @ 40 Deg C Outlet/ performance Parameters Cake solids : 15-20% Filtrate solid recovery: 90-95% Expected Polyelectrolyte dosage: 1-4 kg/ ton (actual usage will depend on jar test result) UPVC drain pipeline connection of suitable dia for disposal of liquid sludge into bar screen chamber as directed and instructed by E.I.C. Qty: 1 Set.
PLC operated Ultra Filtration (UF) System for STP Design, Supply, Installation, Testing & Commissioning of Ultra Filtration (UF) system suitable for hgSBR STP & to meet the desired parameters of treated sewage. The filtration efficiency of the membrane shall be to filter out virus & bacteria also in the range of ten to the power of minus 6 log reduction. The system shall be fully PLC based automatic plant for both filtration & backwash cycle. UV consisting of following items:
PLC Panel: Design, factory testing, supply to site, instalation, testing and commisioning of PLC Panel, Plant autommation, cable laying, connections, fully wired with all required gadgets and relay boards for mounting PLC, Controller - 1 NO., Analog Input 4 Channel - 1 No., Digital Input 16 Channel - 6 No., Analog Output 2 Channel - 1 No., Digital Output 8 Channel - 6 No., HMI 7" (Parameter display/set-points/operations) - 1 No., Power Supply - 1 No., With full programming code writing, installation and testing executed at the site as per the process flow chart & associated instrumentation works includes various level transmitter, level switch, flowmeter, pressure gauge, quantity meter, control cables & signal cables etc. complete as per system requirement and shall be as per proposed design of the agency and duly approved by the department..
UF Feed Pumpset with Starter Panel & electro-mechanical accessories : Design, Supply, installation, testing and commissioning (SITC) of horizontal centrifugal non submersible, closed Impeller, self priming type at uniform flow rate equipped with suitable electrical drive & required associated works etc. like ball typefFootvalve (if required), NRV flap type/ ball type and delivery valve of butterfly type and pressure gauge (MOC-SS) glycerine filled with 4" dial and Rating of Pumps : Flow 4-5 m3 / hr., Head : 30 - 50 mtr , NPSH (A): 3.2 mtr, MOC Pumps : Body C.I., Impeller C.I., Shaft SS / EN - 8, Mech. Seal SS..Motor as required and shall be as per proposed design of the agency and duly approved by the department. Qty: 2 Sets ( 1 W + 1 S).
SITC of 14 SWG MS CRCA sheet starter enclosure, IP 55 wall mounting type, powder coated with approved shade complete with suitable automatic DOL / Star-delta starter with HRC back up protection (Type-II co-ordinated as per IS 13947-4-1) for UF feed pumpset with Working Standby Switch overload protection, current sensing type single phase preventor, internal wiring,manual/ auto operation complete with all accessories as per requirement. 1 No. water level control relay with 3 nos. stainless steel probes similar to M/s Minilec make cat no. WLC D1.The 3 Nos stainless steel probes with required lengths of PVC wires & multiple connectors shall be mounted as per site requirements. The scope also includes ammeter , CT, Indication lamps, contactors, On/Off push button as required, Note: Starter of both pumpset shall be accomodate in single starter box with all electrical accessories etc.
Ultrafiltration Membrane: Design, supply, installation, testing & commissioning of Hollow Fibres/ Tubular, MOC: Polyether Sulphone or as suitable, recovery rate > 85%, filter housing, MS skid etc. complete with all required accessories and also be able to tolerate Chlorine Dosing upto 25 ppm. Rating: 100000 mwco to achieve desired Treated Water Parameters and shall be as per proposed design of the agency and duly approved by the department. The membrane life shall be guaranteed for a period of 5 years of operation. Flow rate: 4 -5 m3/hr and shall be as per proposed design of the agency and duly approved by the department. Qty: 2 sets. ( 1 working + 1 stand by). Design, supply, installation, testing & commissioning of CEB: NaOH & NaoCl, HCL Dosing systems with HDPE Dosing tanks& required accessories etc. complete. NaOH Dosing pump: MOC:PP, 15 [email protected] Kg/cm2, Qty: 2 Nos.(1W+1S), HCl Dosing Pump: MOC:PP,15 [email protected] Kg/cm2, Qty: 2 Nos.(1W+1S), NaoCl Dosing Pump: MOC:PP,15 [email protected] Kg/cm2, Qty: 2 Nos.(1W+1S) & HDPE Tank -200 Litres: 03Nos.
Backflush Pumpsets: Design, supply, installation, testing and commissioning (SITC) of centrifugal non submersible, Self Priming type at uniform flow rate equipped with suitable electrical drive & required associated works etc. like ball type footvalve, NRV ball type and delivery valve of butterfly type with PN Rating of 1.0 min. and pressure gauge (MOC-S.S.) -glycerine filled with 4" Dial, backflush tank - 1no of required capacity , Rating of Pumps : Flow 10 - 15 m3 / hr @35 mtr, NPSH (A): 3.2 mtr, MOC Pumps : Body C.I., Impeller C.I., Shaft SS / EN - 8, Mech. Seal SS..Motor 10 HP or as per requirement and shall be as per proposed design of the agency and duly approved by the department.. Qty: 2 Sets ( 1 W + 1 S). UF System Piping & associated works: Design, Supply, Installation, Testing and Commissioning of interconnecteing piping for UF System of suitable dia CPVC SCH 40 along with required fittings, valves, pressure gauges, Specials, PP/SS basket strainer, level switch, solenoid valves, rotameter, flowmeter etc complete and shall be as per proposed design of the agency and duly approved by the department.. .
STP Plant piping, valves and associated works Entire STP Plant piping including treated water pumpset , Instrumentation & associated works shall be considered in the scope of works for items covered under PART-A of this SOQ. Deptt. Will not pay any extra amount under any account. Note: Piping & associated works for Submersible Sewage sump Pumpset ( Item No. 6 of this SOQ /Part-a) shall be measured under relevant item of this SOQ.
Any other works which are not included in schedule of quantities, scope of works but are required/ necessary for succesful commissioning of STP & put plant operational, shall be in the scope of contractor. Deptt. Will not pay any extra amount for such works.
Ozonator (Ozone Generating Equipment) Supply, installation, testing & commssioing of Ozonator (Ozone Generating Equipment) & Ozonator shall be able to produce 40 grams O3 / hr capacity alongwith ozone production chamber, frequency inverter, pannel assembly, ventury injector, booster pump , required valves, inlet & outlet line etc. complete with all required accessories as per requirement for succesful installation of Ozonator.
Ultravoilet Light Supply, installation, testing & commssioing (SITC) of UV system (Ultra Voilet Light) with Electrical ballast type electronic, reactor MOC- SS 316, UV dose- 600 J/m2, lamps ( 4 Nos) for disinfecton of sewage water. The work includes SITC of required piping, valves, connections, automatic quartz sleeve wiping system or self cleaning system, control panel, cables, MS powder coated control panel, all end connections, lamp replacement reminder, lamp failure indication with alarm, max. operating pressure - 120 psi, working on 220-240V / 50-60 Hz etc. complete with all necessary accessories with bypass arrangement as per requirement for succesful installation of UV system & shall be Compatible with hgSBR STP. Flow rate : 5 m3/hr @ 30 mtr head
Dewatering Pumps Supply, installation, testing & commissioning of Submersible dewatering Pump Set to give a discharge of 3 m3/hr and total head of 20 mtr with solid handling capacity upto 20 mm at uniform flow rate equipped with electrical drive & associated works with PVC flexible hose pipe of 40 mm dia, with approx. 70 m length etc. complete in all respects as per site requirements and as directed by E-I-C.
Shed & Roofing Design, providing and fixing curved shaped roofing including facia etc with 'Galvalume' toughened permanently colour coated roofing sheet 0.5mm thick of M/s CRIL 'HISPAN' with special Polyester colour coating of 20 microns thickness(DFT) on exposed surfaces and 5 microns(DFT) on unexposed surfaces over 5 microns(DFT) of Polyester primer on both surfaces of CRCA sheet of 550Mpa with hot dip coating of 150 gms/ SqM Aluminium Zinc Alloy all as permanufacturers specifications of approved shade and colour, fixing to trusses at all levels including placing and fixing in position, bending to shape, cost of all materials, labour, tools and plants required for completion of work, all overlaps, metring wherever necessary,stainless steel anchor bolts, nuts, washers, making the roof leakproof all as permanufacturer's specification all etc. complete & shall be as per proposed design of the agency and duly approved by the department.
Submersible Sewage Sump Pumps Supply, installation, testing & commissioning of Submersible Non Clog, single stage, single entry pumps connected to TEFC submersible motor for 415 + 10% volts, 3 phase, 50 cycles A.C. power supply with mechanical seal, pump connector unit with rubber diaphragm and bend, vertical discharge pipe. The pump shall be provided with a lifting devise of pull chain/guide rail. Pumps suitable to handle solids upto 20 mm size with C.I. body, SS304/ EN8 shaft, CI impeller). Rating of Pumps : Flow - 6 m3 / hr., Head : 15 mtr, Mechanical seal, solid handling capacity- 20 mm, Motor as per requirement. Qty: 2 Sets. ( 1 working + 1 stand by- Cascade operation)
Panel mounted microprocessor based multi pump controller with large graphical display with VGA 240 x 320 pixels and IP 55 enclosure, diodes to indicate pump ready, earthing, pump running and fault condition, Cascade Operation. Each incomer and Outgoing feeder should be capable for protection against Overload, Short Circuit and Phase reversal condition and shall be capable to communicate with other controllers following. The PLC shall support MODBUS-IP communication for its compatability to intergrate with 3rd party BAS system. Controller shall authorise Read/Write command via BMS.All alarms should be displayed in the controller. System should be equipped with dry running protection. Indication of all type of faults / on-off status / electrical parameters shall be available on panel and central IBMS monitors. On-off operation for all pumps shall be available on BMS system.Scope shall also include supply, laying, termination of control and power cables of adequate size and arrangemnt of cable trayfrom pump to control panel etc. to complete the job. Electronic type low, Medium & High water level controller with LED panel to operate pump (necessary contacts along with minimum one PLC operated spare contacts required),level controller with operational mode as one pump working at Medium level, both pumps at High level with a hooter alarm and cut off at Low level complete the job.
Mounting Height (Low Level ): (Sump) Mounting Height (Medium Level) : (Sump) Mounting Height (Hight Level ): (Sump) with probe & all control wiring from Pump room Panel to Sump to operate the system automatic/manual & shall prevent the pump from dry running. Scope shall also includes supply, laying, testing & commissioning (underground/ aboveground/ floor) power and control cable of required size, termination, cable tray from Pump to Control panel, control cable as whereever required etc. complete the job. Scope shall also includes supply, laying, testing & commissioning (underground/ aboveground/ floor) of CPVC SCH 80, 3" NB pipeline (approx. 100 mtr length) with fittings/ specials to correct line, level and plumb, leak proof threaded / welded joints, all required valves of rating PN 10 like NRV, isolation valve, SV, pressure gauge discharge header, bypass arrangements to equalisation tank with all required valves etc. to completethe job as per site requirement & as directed by Engineer-In-Charge.
Treated water pumpset with electrical drive & associated works Supply, installation, testing and commissioning (SITC) of centrifugal non-clog, Non submersible, horizontal mounted, flooded positive suction pumpset at uniform flow rate equipped with suitable electrical drive with all associated works etc. and shall be as per proposed design of the agency and duly approved by the department. Pumpset shall be variable speed, in-line installation, Electronic type low water level controller with LED panel to operate pump (necessary contacts along with minimum one PLC operated spare contacts required), with probe & all control wiring from Panel to tank to operate the system automatic/manual & shall prevent the pump from dry running.
Operation of pumpsets shall be fully automatic by PLC:- The PLC shall support MODBUS-IP communication for its compatability to intergrate with 3rd party BAS system. Controller shall authorise Read/Write command via BMS.System should be capable to compensate for frictional losses at lower flows. All alarms should be displayed in the controller. System should be equipped with dry running protection. Indication of all type of faults / on-off status / electrical parameters shall be available on panel and central IBMS monitors. On-off operation for all pumps shall be available on BMS system etc. complete as per requirement.
Flushing water pumpset:- Rating of Pumps : Flow 6 m3 / hr., Head :70 mtr, MOC Pumps : Body C.I., Impeller C.I., Shaft SS/ EN8, Solid handlind capacity upto 8 mm, Seal- Mechanical seal, Motor as per requirement. Qty- 3 sets (2 Working + 1 Standby - cascade operation).
Gardening water pumpset:- Rating of Pumps : Flow 8 m3 / hr., Head :50 mtr, MOC Pumps : Body C.I., Impeller C.I., Shaft SS/EN8, Solid handlind capacity upto 8 mm, Seal- Mechanical seal, Motor as per requirement. Qty- 3 sets (2 Working + 1 Standby - cascade operation).
Treated water pumpset (Pond) :- Rating of Pumps : Flow 15 m3 / hr., Head :50 mtr, MOC Pumps : Body C.I., Impeller C.I., Shaft SS/EN8, Solid handlind capacity upto 8 mm, Seal- Mechanical seal, Motor as per requirement. Qty- 3 sets (2 Working + 1 Standby - cascade operation).
Treated water transfer pumpset ( From PLOT- B STP TO PLOT -A STP):- Rating of Pumps : Flow 10 m3 / hr., Head :70 mtr, MOC Pumps : Body C.I., Impeller C.I., Shaft SS/EN8, Solid handlind capacity upto 8 mm, Seal- Mechanical seal, Motor as per requirement..Qty- 3 sets (2 Working + 1 Standby - cascade operation). Electronic type low, Medium & High water level controller with LED panel to operate pump (necessary contacts along with minimum one PLC operated spare contacts required),level controller with operational mode as one pump working at Medium level, both pumps at High level with a hooter alarm and cut off at Low level complete the job. -Mounting Height (Low Level ): (Sump), Mounting Height (Low Level ): (Sump), Mounting Height (Hight Level ): (Sump) with probe & all control wiring from Pump room Panel to Sump to operate the system automatic/manual & shall prevent the pump from dry running.
Road cutting & re-surfacing Cutting the existing asphalt road and demolishing WBM or BBM including rubble soling if any for providing services and making good the same after the work is satisfactorily completed, including relaying of soling doing water bound macadam, bituminous bound macadam road providing and laying 50 mm thick asphaltic layer etc, complete as directed by E-I-C.
TOTAL OF PART-A
PART-B: ELECTRICAL, INSTRUMENTATION, AUTOMATION & ASSOCIATED WORKS FOR STP PLANT
Supply, Instalation, testing and commisioning of electrical equipment: MCC panel, RVMCC panel, PLC Panel & associated instrumentation works.
Fabrication, factory testing, supply to site installation, testing and commissioning of process motor control centre (PMCC panel), cable laying, connection, testing and commissioning etc.
Fabrication, supply, installation and testing and commissioning of remote valve MCC (RVMCC), cable laying, connection, testing and commissioning of motorised remote valves and process motors.
Supply, instalation, testing and commisionin of Plant autommation and insrumentation PLC panel : Fully wired with all required gadgets and relay boards for mounting PLC, Controller - 1 NO., Analog Input 4 Channel or as required- 1 No., Digital Input 16 Channel - 6 No., Analog Output 2 Channel - 1 No., Digital Output 8 Channel - 6 No., HMI 7" (Parameter display/set-points/operations) - 1 No., Power Supply - 1 No., with full programming code writing, installation and testing executed at the site as per the process flow chart & all as per system requirement.
Supply and fixing of Level Transmitter - Ultrasonic Level Transmitter Supply and fixing of Flote type level Switch - Range 5.0 m Supply and instalation of Flowmeter Magnetic Flow Meter / Dial Gauge ventury flow meter - 65 NB Line , Flow range - 0 - 50.0 m3/hr - Qty- 1no. Magnetic Flow Meter / Dial Gauge ventury flow meter - 50 NB Line , Flow range - 0 - 50.0 m3/hr Qty- 2 Nos Glass tube Rotameter - Flange type mounting , Flow range 0 - 50 m3/hr. Supply and instalation of quantity meter Quantity meter - 50 NB, indicator and transmitter - For Liquid, Flow range 0 - 50 m3 / hr. Quantity meter - 80 NB, indicator and transmitter - For Liquid, Flow range 0 - 50 m3 / hr. Supply and fixing of Dissolved Oxygen - DO Sensor With Controller, indicator and tranmitter, upto 3.0 m Depth Supply and fixing of Differiatial Pressure Gauge - Differential Pressure Gauge Range : 0 – 1 kg/cm2 Pressure Gauges - Bourdon Sensing Pressure Gauge ( glycerine filled) Range : 0-10Kg/cm2, It includes pipe fitting with vent valve and drain valve.
Cables - Core cables and Signal cables: 1 Pair/2 Core or as required,1 sq mm/1.5 sq mm Supply and installation of power socket boxes with 5 pin metal clad socket and plug top with 32a cat-c MCB of 4 pole, fixing against wall with suitable support Digital energy meter
Power Cables & Control Cables (FRLS) Supply, installation, testing & commissioning of 1.1 KV grade multicore copper soild/ stranded conductor,HRPVC insulated, FRLS PVC sheated armoured power & control cable with suitable fixing arragement & accessories as per system requirement & as directed by Engineer-In-Charge (E.I.C.)
Cable Tray Supply & fixing ladder type GI cable trays with vertical sides on both ends and suitable MS supports i.e.channel, beam, angle including concrete bolts, hold fast etc. The scope includes supply of readymade bends, reducers,Tee, covers etc. as required as per instructions of EIC. Note : The scope of work also includes End jointing of above cables by crimping with supply of all jointing materials like solderless tinned copper cable socket, cable glands, gland earthing, insulation tape, flux, duplicate interconnection between gland earthing strip & to the nearest earthing bus terminals as per the drawings, specifications and as per the instructions of the Engineer-in-charge.
Earthing system Supply, installation, testing & commissioning of earthing system ( 2 sets) & associated accessories, etc. complete as per requirements & as per the instructions of E.I.C. Note 1) Measurements of resistance of each earth station & resistance of complete scheme of earthing layout must be measured & recorded 2. Jointing of the earth strip shall be with brass nuts bolts and also with solder joints. 3. Jointing of the earth wire shall be with solder joints with tinned cable sockets GI earth plate electrode 600 x 600 x 6 mm earth station 2.5 m below ground level conforming to IS 3043 complete with all required materials like coke/charcoal, salt, brass nut-bolts & washers, watering arrangement, G.I pipe (B class) masonary chamber, min. 10mm thick chequered plate cover associated materials like 40 x 40 x 5mm angle iron frame work, hinges, locking arrangement etc. & excavation in all types of soil, refilling & removal of excess earth.
GI strip/wire fixed to wall/side of trench/ slab/column/beam/shaft with 5mm thick G.I spacers & GI saddles or on existing cable tray with saddles or in ground at 750 mm below including excavation in all types of soil with protective baked bricks, refilling & removal of excess earth within a radius of 500 m temporary reinstatement & back filling of trench, interconnections of earth strip/wire with brass nuts, bolts & washers and solder jointing, painting with two coats of black bituminous compound for earth wire/strip in ground & green enamel paint for earth wire/strip on surface , etc. MOC: 25 x 6 mm GI Strip & 8 SWG copper wire
TOTAL OF PART-B
PART - C - OPERATION & MAINTENANCE OF STP
Statutory approval for hgSBR plant Statutory approval/ Permission : Obtaining Statutory approval for above plant from local bodies/ Muncipal corporation, State bodies/ State pollution control board, MOEF and obtaining permissions & clearances for running the plant on regular basis.
Operation & Maintenance of hgSBR STP & Ultrafiltration (UF) plant Operation & Maintenance of plant : Operation & Maintenance of above plant for one year on 24 x 7 basis in three shift during defect liability period from the date of succesful commissioning & handing over the plant to the Department/ User including deployment of technical manpower (minimum 1 person per shift). The scope also includes the follwing Note 1: All chemicals required for period of one year including initial charge of chemicals. Note 2: Cost of all chemicals required for poly dosing system for period of one year including initial charge of chemicals. Note-3: Sodium Hypo Chloirde solution ( 5 to 10 % concentration of chlorine) for dis-infecton of treated sewage outlet from STP plant and Chlorine dosing system for period of one year including initial charge of chemicals. Note-4: Disposal of collected oil, grease, floating materials, grit should be disposed off at suitable location within radius of 2 KM at regular intervals as per instruction of E.I.C./ Department. Contractor has to make necessary arrangement at his own cost for disposal with necessary arrangement for transportation, manpower etc..
Testing Of Samples Testing samples & submiting the testing report to Department of raw sewage at bar screen/ Grit chamber chamber inlet ( 01 Sample) & treated effluent from STP ( 01 Sample) . Sample testing includes the parameters like PH, COD, BOD, TSS, Oil & grease, residual chlorine, fecal coliform, NH4-N, N-Total, Total Phosphorous as mention in Design Basis. Sample should be tested from approved lab like NABET Accredited, MOEF, SPCB or Govt. approved lab as per instruction and as directed by Engineer-In-charge (E.I.C.). Note: One sample for raw sewage & One sample for treated sewage will be count as a one set.
TOTAL OF PART-C
NET TOTAL Part-V-B: 55 KLD STP at Plot-B
Part-V-C: 50 KLD ETP at Plot-A
PART - A : MECHANICAL & ASSOCIATED WORKS FOR ETP PLANT NOTES : The following items shall be considered in the scope of works for Design, supply, installation, testing & commissioning (DSITC) of ETP & assocaited works for items covered under PART-A of this SOQ. The rates shall be all inclusive including all taxes & duties and Deptt. Will not pay any extra amount under any account.
i) Electrical motors : All rotating mechanical equipments of ETP like pumps/ blowers/ centrifuge/agitators/ centrifuge/dosing system etc., whether specifically indicated in the respective item or not, shall be equipped with high efficiency electrical motor IE2/ IE3 , suitably rated, squirrel cage induction motor, continuous duty with suitable synchronous speed (@3000/ 1500/1000 rpm) , class 'F' insulation, IP-55 degree of protection, rated to operate at 415 V +/- 10%, 50 Hz +/- 3%, 3 phase, AC supply, etc. as per requirement. ii) Base frame & accessories: MS common base frame for installation of equipment's alongwith foundation bolts, flexible lovejoy/ flange/ bush coupling, coupling guard, anti vibration pads, standard fittings, flanges, other accessories etc. complete as per specification, drawings and instruction of Engineer-In-Charge (E.I.C.) iii) Mansoon Protection: Canopy made out of 20 SWG thick FRP sheet to protect the equipmets from monsoon, if equipment's are exposed to open area.
v) Foundations for Pumpsets & Equipment:- Providing Design-Mix rainforcement Cement Concrete Foundation for various pumps, blowers & other mechanical equipment of STP of M-30 by weight batching using graded stone aggregate of 20 mm maximum size including mechanical mixing & vibration, consolidation, finishing, curing etc. as specified and also including dewatering , if any , cost of form work, shuttering & steeel reinforcement, including nosing all around by 50 x 50 x 5 mm angle etc, all complere as per specification and as directed by EIC. vi) Supports for piping & header : Providing PCC supports for pipe supports/ headers of suitable size with cement morter 1:2:4 etc,all complere as per specification and as directed by EIC.
vii) Supply, installation/ fixing in position structural steel of angle, flats, joists, channel, I Beam, plain / chequered plates for support to pipes above Ground level & other miscellaneous works etc., including cutting, fabricating, welding, erecting in position including supplying & fixing embedded parts for fixing supports in concrete etc. complete as per specification and as directed by the E.I.C Any other works which are not included in schedule of quantities, scope of works but are required/ necessary for succesful commissioning & operation of Effluent Treatment Plant included in the scope of contractor. Deptt. Will not pay any extra amount under any account.
EFFLUENT TREATMENT PLANT (ETP) Design (Electro-mechanical excluding Architectural & Structural), supply, installation, testing, commissioning including associated Electrical, Mechanical, Instrumentation & allied works for Effluent Treatment Plant of Capacity 50 KLD . The ETP shall comprise the following equipment and materials as per specification, drawings and accepted process of treatment, including cost of all materials, cost of labour, tools and plants and accessories to make plant operational. However, the actual components of ETP shall be based on proposed design of agency & duly approved by Department.
Bar Screen Design, supply, installation, testing and commissioning of Bar screen made of SS 304 as per site condition and as directed by Engineer-In-charge (E.I.C.) . Type : Manual, MOC : SS 304 Coarse bar screen: Fabricated by flats size 25 x 5 mm with spacing 10 mm and beeding at the edge, fitted with handle. Two guide rail fabrication in which bar screen will slide and fitted at the side wall of grit chamber as per instruction of Engineering - in - charge. Qty: 1 No. Fine bar screen: Made from Perforated plate of thickness 3.0 mm with Circular hole of dia < 5 mm and pitch 10.0 mm. It should have bedding at all the edges and one handle for handling. Two guide rail fabrication in which bar screen will slide and fitted at the side wall of grit chamber as per instruction of Engineering - in - charge. Qty: 1 No. Flow weir: Proportional type flow weir of size 500 x 500 mm or as suitable with guide rail frame. Qty: 1 No. All piping, fittings, connections, valves etc complete to be fixed in equalisation tank as per site requirements
Raw Effluent Transfer Pumps at Equilisation tank Supply, installation, testing and commissioning (SITC) of non-clog centrifugal Non submersible horizontal mounted pumpset at uniform flow rate equipped with suitable electrical drive & required associated works etc. Rating of Pumps : Flow 4 m3 / hr, Head : 20 mtr, MOC Pumps : Body C.I., Impeller C.I., Shaft SS / EN - 8, Mechanical seal, solid handling capacity - 8mm (max), Motor as per requirement. The Piping MOC shall be CPVC, schedule - 80 and shall be as per proposed design of the agency and duly approved by the department. Qty: 2 Sets. ( 1 working + 1 stand by)
Air Blower for Equalisation tank & Sludge Holding tank with electrical drive & associated works Design, supply, installation, testing and commissioning of Twin Lobe/ Root air blower driven through “V” belt or directly coupled through flexible coupling & equipped with VFD enable motor drive & associated works including connection to air lines & fittings etc complete. Rating of Blowers : Dicsharge capacity - 50 m3 / hr , differential pressure : 0.45- 0.65 kg/sq.cm., Body C.I., M.S. safeguard cover, VFD enable motor as per requirement. The final parameters shall be as per proposed design of the agency and duly approved by the department. Qty: 2 Sets ( 1 Working + 1 Standby).
Clarriffloculator assebmbly with Mixer ( Clarifier + Floculator units) Clariflocculator is a combined flocculator and clarifier in which floc formation and its subsequent removal by sedimentation occur. It has two concentric tanks where the inner tank serves as a flocculation basin and the outer tank serves as a clarifier.
Scrapper mechanism for Primary clarifier Design, Supply, installation, testing and commissioning of suitable scrapper mechanism for Primary clarrifier tank ( MOC: MS with epoxy paint ) with required support suitable for installation on RCC/ PCC platform etc. complete driven by suitable drive mechanism (gear motor) & shall be operated on 220 V single phase supply and shall be mounted as per site situ with necessary valves, piping etc. complete along with first charge of chemicals as required. suitable for 50 KLD ETP plant Type: Vertical mounted gear motor and base frame assembly Shaft & Impellar : SS RPM: 100 or suitable HP- 1 or suitable Suitable arrangement for fixing on platform.
Flocculator unit Design, Supply, installation, testing and commissioning of agitator/ Mixer (MOC- S.S.304) driven by suitable drive mechanism (gear motor and agitator mechanism). Agitator shall be operated on 220 V single phase supply and shall be mounted as per site situ with necessary valves, piping etc. complete etc. complete complete suitable for 50 KLD ETP plant along with first charge of chemicals as required. Type: Vertical mounted gear motor and base frame assembly Shaft & Impellar : SS RPM: 100 or suitable HP- 1 or suitable Suitable arrangement for fixing Agitator (mixer) on platform. All units have suitable inlet flange & outlet flange, interconnecting piping, valves, drain, bypass provision etc. complete as per site condition & requirements. Providing suitable MS platform for Clarriffloculator assebmbly with Mixer ( Clarifier + Floculator units) with suitable MS angles, channels, plates etc. as per site requirements Design, supply & fixing in position at site flocullation unit (MS with epoxy painted) of suitable dia and shall be installed inside the clarifier tank with suitable dia pipeline
Dosing System Dosing system: Supply, installation, testing and commissioning of on line manual / adjustable automatic electronic dosing unit with automatically operated dosing pump. The pump shall be operated on 220 V single phase supply and shall be mounted directly on the top of the tank with necessary nozzles, valves, piping etc. complete along wth first charge of chemicals as required. Dosing system comprises of following dosing system. (a) Acid dosing system (pH correction dosing pump) with Agitator : 2 Sets ( 1 Working + 1 stand by) (b) Poly Dewatering system ( Polydosing pump) with Agitator : 2 Sets ( 1 Working + 1 stand by) (c) Coagulants dosing system (coagulant dosing pump) with Agitator : 2 Sets ( 1 Working + 1 stand by) (d) Alkali dosing system (pH correction dosing pump) with Agitator : 2 Sets ( 1 Working + 1 stand by) (e) Sodium Hypochlorite ( NaoCl) system (Disinfection dosing pump) with Agitator : 2 Sets ( 1 Working + 1 stand by) Detailed Technical specification, capacity, MOC etc for each dosing system & agitator are as foloows.
Dosing system: 10 SETS in total ( 5 Working + 5Standby) Pump Capacity: 0- 20 LPH Supply, installation, testing and commissioning of Electronically actuated diaphragm type / Mechanically actuated diaphragm type / Hydraulic diaphragm type dosing pump Min. Actuating Pressure - 0.3 kg/sq cm Max. Working Pressure - 3.0 kg/sq cm Level Switch HP- 1 or suitable Head - suitable MOC: HDPE/PP Dosing tank : 1 no of 200 Ltr capacity
Agitator system: 10 SETS in total ( 5 Working + 5Standby) Supply, installation, testing and commissioning of Agitator/ Stirrer (MOC: SS & RPM 100) . The agitator with suitable drive mechanism shall be operated on 220 V single phase supply and shall be mounted directly on the tank top with necessary valves, piping etc. complete. Type- Vertical mounted gear motor Power rating of motor - 1 HP or as suitable Suitable base frame assembly for installation of units PH Control Low PH- NaOH/ Ca(OH)2 - Alkali dosing High PH- H2SO4/ HCL Coagulants- FeCls, Aluminium Sulphate ( Alum)
Design, supply, Installation and commisoning of filters with the process lines and associated valves etc and mounting on the floor with PCC/ RCC foundation.
Pressure Sand Filter (PSF) with associated works Design, Supply, installation and commissioning of vertical pressure sand filter (PSF)/ Multi-grade filter (MGF) with internal components, required accessories like piping, fittings, pressure guages, air vent valve, valves, flange connections, nozzles, mounting etc. with initial charge of Filter media as required. The design of filter & media shall be as per proposed by the agency and duly approved by the department for obtaining desired treated effluent parameters. Piping: Laterals constructed in MS/CPVC and all frontal piping works constructed in CPVC. Dia: 800 mm HOS: 1600 mm Shell thick: 6 mm Dish thick: 8 mm MOC: MS- Epoxy Specific flow rate – filter - 5 m3/hr./m2 Specific flow rate – backwash - 10 m3/hr./m2 PSF shall be painted internally and externally with one coat of epoxy primer with two coats of anticorrosive epoxy paint of approved color. Multi Grade Filter (MGF) filled with different grade of media,
Multimedia consist of (sand + fine sand + and different size of garnet), bed depth equally distributed filter media in multiple layers, velocity across the filter 8.0 – 10.0 m/hr. max., for filtration up to 50 micron particle The filter shall be fitted with inlet distribution and bottom collecting system. Qty: 1 Set
Activated Carbon Filter (ACF) with associated works Design, Supply, installation and commissioning of activated carbon filter with with internal components, required accessories like piping, fittings, pressure guages, air vent valve, valves,flange connections, nozzles, mounting etc. with initial charge of filter media as required. The design of filter & media shall be as per proposed by the agency and duly approved by the department for obtaining desired treated sewage parameters. Piping: Laterals constructed in MS/CPVC and all frontal piping works constructed in CPVC. Dia: 800 mm HOS: 1600 mm Shell thick: 6 mm Dish thick: 8 mm MOC: MS- Epoxy Specific flow rate – filter - 5 m3/hr./m2 Specific flow rate – backwash - 10 m3/hr./m2 ACF shall be painted internally and externally with one coat of epoxy primer with two coats of anticorrosive epoxy paint of approved color.
Activated carbon filter filled with activated charcoal media, Single layer of activated carbon supported by gravels and pebbles at bottom, coconut shell carbon, adsorption efficiency – up to 90%, chlorine, color and odor removal –85 to 90%, Filter bed shall withstand the maximum pressure drop encountered during the operation, without breakdown of filter media, Filter media shall be non-toxic and shall not impart color, odor or taste to the water. The filter shall be fitted with inlet distribution and bottom collecting system. Qty: 1 Set
Filter Feed Pump with electrical drive & associated works Design, Supply, installation, testing and commissioning (SITC) of non-clog non-submersible centrifugal pumpset at uniform flow rate equipped with suitable electrical drive & required associated works etc. Rating of Pumps : Flow 4 m3 / hr, Head : 30 mtr, MOC Pumps : Body C.I., Impeller C.I., Shaft SS / EN - 8, Mechanical seal, solid handling capacity - 8mm (max), Motor as per requirement. The Piping MOC shall be CPVC, schedule - 80 and shall be as per proposed design of the agency and duly approved by the department. Qty: 2 Sets. ( 1 working + 1 stand by)
Backwash Pumpset with electrical drive & associated works Supply, installation, testing and commissioning (SITC) of non-clog Centrifugal Non submersible, flooded positive suction backwash pumpset at uniform flow rate equipped with suitable electrical drive & required associated works etc. Rating of Pumps : Flow - 10 m3 / hr., Head : 35 mtr, MOC Pumps : Body C.I., Impeller C.I., Shaft SS / EN - 8, Mechanical seal, solid handling capacity- 10 mm (max) , Motor as per requirement.. The Piping MOC shall be CPVC, schedule - 80 and shall be as per proposed design of the agency and duly approved by the department. Qty: 1 Set.
Backwash Tank: MOC: PP/ FRP Capacity: 5000 ltr liquid: clear water Mounting: Horizontal/ vertical cylindrical tank Sevice area: STP- open atm Mounting base: Roof top/terrace – mounted on raised platform. Manhole: Minimum one manhole with the size of 500 mm. Manhole with door Opening: Minimum one opening at the base and one opening at the top with flat face
Sludge Transfer pump with electrical drive & associated works Design, Supply, installation, testing and commissioning (SITC) of non-clog Centrifugal/ screw type centrifugal Non submersible, flooded positive suction sludge transfer pumpset with solid handling capacity of up to 20 mm (max.) at uniform flow rate equipped with electrical drive & associated works etc. Rating of Pumps : Flow 2 m3 / hr., Head : 15 mtr, NPSH (A): 3.2 mtr, MOC Pumps : Body C.I., Impeller C.I., Shaft SS / EN - 8, seal- mechanical/ gland packing, Motor as per requirement and shall be as per proposed design of the agency and duly approved by the department. Qty: 1 Set.
Sludge Dewatering System Design, Supply, Installation, testing & commissioing of sludge dewatering system consisting of following items i.e. sludge feed pump & decanter centrifuge
Sludge feed pump to Centrifuge with electrical drive & associated works Supply, installation, testing & commissioing of horizontal Centrifugal type non clog, non submersible type with solid handling capacity of up to 20 mm (max.) at uniform flow rate equipped with electrical drive & associated works etc. Rating of Pumps : Flow 1- 2 m3 / hr., Head :15 - 40 mtr. MOC Pumps : Body C.I., Impeller C.I., Shaft SS / EN - 8, seal- mechanical/ gland packing, Motor as per requirement. Qty: 1 set.
Centrifuge decanter with with electrical drive & associated works Design, Supply, installation, testing & commissioing of sludge dewatering system consists of top discharge Verical type basket centrifuge with basket MOC- SS 304 & MS enclosure with suitable driven arrangement coupled with suitable capacity motor, etc. complete suitable for ETP as per proposed design of the agency and duly approved by the department. Capacity: 2 m3/hr feed : 1- 2 m3 / hr Feed Solids: 1-4% Temperature @ 40 Deg C Outlet/ performance Parameters Cake solids : 15-20% Filtrate solid recovery: 90-95% Expected Polyelectrolyte dosage: 1-4 kg/ ton (actual usage will depend on jar test result) UPVC drain pipeline connection of suitable dia for disposal of liquid sludge into bar screen chamber as directed and instructed by E.I.C. Qty: 1 Set.
ETP Plant piping, valves and associated works Entire ETP Plant piping including treated water pumpset , Instrumentation & associated works shall be considered in the scope of works for items covered under PART-A of this SOQ. Deptt. Will not pay any extra amount under any account. Note: Piping & associated works for Submersible Sewage sump Pumpset ( Item No. 4 of this SOQ /Part-a) shall be measured under relevant item of this SOQ. Design, supply, installation, testing and commissioning of interconnecting piping of suitable dia CPVC Sch 80 / (aboveground/ underground) alongwith required fittings/ specials, pressure gauge, all required valves within the battery limit (Approx. 80m Length from the installed equipment of ETP). The scope includes the suitable suction & discharge line, common header of required dia, associated piping & required valves, connections for drain, bypass, filter backwash, recirculation etc.complete all as per proposed design of agency and duly approved by the department for successful intallation of equipments/machinery's/plant & unit/ system operational. For Treated water pumpsets : MOC- GI , 'C' class, 3" dia pipeline (approx. 30 mtr length excluding battery limit ) from the installed treated water pumpsets for further connections as instructed by E.I.C.
Ultravoilet Light Supply, installation, testing & commssioing (SITC) of UV system (Ultra Voilet Light) with Electrical ballast type electronic, reactor MOC- SS 316, UV dose- 600 J/m2, lamps ( 4 Nos) for disinfecton of sewage water. The work includes SITC of required piping, valves, connections, automatic quartz sleeve wiping system or self cleaning system, control panel, cables, MS powder coated control panel, all end connections, lamp replacement reminder, lamp failure indication with alarm, max. operating pressure - 120 psi, working on 220-240V / 50-60 Hz etc. complete with all necessary accessories with bypass arrangement as per requirement for succesful installation of UV system & shall be Compatible with hgSBR STP. Flow rate : 5 m3/hr @ 30 mtr head
Submersible Effluent Sump Pumpsets Supply, installation, testing & commissioning of Submersible Non Clog, single stage, single entry pumps connected to TEFC submersible motor for 415 + 10% volts, 3 phase, 50 cycles A.C. power supply with mechanical seal, pump connector unit with rubber diaphragm and bend, vertical discharge pipe. The pump shall be provided with a lifting devise of pull chain/guide rail. Pumps suitable to handle solids upto 20 mm size with C.I. body, SS304/ EN8 shaft, CI impeller). Rating of Pumps : Flow - 6 m3 / hr., Head : 15 mtr, Mechanical seal, solid handling capacity- 20 mm, Motor as per requirement. Qty: 2 Sets. ( 1 working + 1 stand by- Cascade operation)
Panel mounted microprocessor based multi pump controller with large graphical display with VGA 240 x 320 pixels and IP 55 enclosure, diodes to indicate pump ready, earthing, pump running and fault condition, Cascade Operation. Each incomer and Outgoing feeder should be capable for protection against Overload, Short Circuit and Phase reversal condition and shall be capable to communicate with other controllers following. The PLC shall support MODBUS-IP communication for its compatability to intergrate with 3rd party BAS system. Controller shall authorise Read/Write command via BMS.All alarms should be displayed in the controller. System should be equipped with dry running protection. Indication of all type of faults / on-off status / electrical parameters shall be available on panel and central IBMS monitors. On-off operation for all pumps shall be available on BMS system.Scope shall also include supply, laying, termination of control and power cables of adequate size and arrangemnt of cable trayfrom pump to control panel etc. to complete the job. Electronic type low, Medium & High water level controller with LED panel to operate pump (necessary contacts along with minimum one PLC operated spare contacts required),level controller with operational mode as one pump working at Medium level, both pumps at High level with a hooter alarm and cut off at Low level complete the job. Mounting Height (Low Level ): (Sump) Mounting Height (Medium Level) : (Sump) Mounting Height (Hight Level ): (Sump) with probe & all control wiring from Pump room Panel to Sump to operate the system automatic/manual & shall prevent the pump from dry running.
Scope shall also includes supply, laying, testing & commissioning (underground/ aboveground/ floor) of CPVC SCH 80, 3" NB pipeline (approx. 100 mtr length) with fittings/ specials to correct line, level and plumb, leak proof threaded / welded joints, all required valves of rating PN 10 like NRV, isolation valve, SV, pressure gauge discharge header, bypass arrangements to equalisation tank with all required valves etc. to completethe job as per site requirement & as directed by Engineer-In-Charge. Scope shall also includes supply, laying, testing & commissioning (underground/ aboveground/ floor) power and control cable of required size, termination, cable tray from Pump to Control panel, control cable as whereever required etc. complete the job.
Treated Effluent Transfer Pumps ( ETP To STP Treated water tank ) with electrical drive & associated works Supply, installation, testing and commissioning (SITC) of centrifugal non-clog, Non submersible, horizontal mounted at uniform flow rate equipped with suitable electrical drive with all associated works etc. and shall be as per proposed design of the agency and duly approved by the department. Pumpset shall be variable speed, in-line installation, Electronic type low water level controller with LED panel to operate pump (necessary contacts along with minimum one PLC operated spare contacts required), with probe & all control wiring from Panel to tank to operate the system automatic/manual & shall prevent the pump from dry running.
Operation of pumpsets shall be fully automatic by PLC:- The PLC shall support MODBUS-IP communication for its compatability to intergrate with 3rd party BAS system. Controller shall authorise Read/Write command via BMS.System should be capable to compensate for frictional losses at lower flows. All alarms should be displayed in the controller. System should be equipped with dry running protection. Indication of all type of faults / on-off status / electrical parameters shall be available on panel and central IBMS monitors. On-off operation for all pumps shall be available on BMS system etc. complete as per requirement. Rating of Pumps : Flow 10 m3 / hr., Head :50 mtr, NPSH (A) 3.2 mtr, MOC Pumps : Body C.I., Impeller C.I., Shaft SS/ EN8, Solid handlind capacity upto 8 mm, Seal- Mechanical seal, Motor as per requirement..Qty- 2 sets (2 Working + 1 Standby - cascade operation).
TOTAL OF PART-A
PART-B: ELECTRICAL, INSTRUMENTATION, AUTOMATION & ASSOCIATED WORKS FOR ETP PLANT
Supply, Instalation, testing and commisioning of electrical equipment: MCC panel, RVMCC panel, PLC Panel & associated instrumentation works.
Fabrication, factory testing, supply to site installation, testing and commissioning of process motor control centre (PMCC panel), cable laying, connection, testing and commissioning etc.
Fabrication, supply, installation and testing and commissioning of remote valve MCC (RVMCC), cable laying, connection, testing and commissioning of motorised remote valves and process motors.
Supply, instalation, testing and commisionin of Plant autommation and insrumentation PLC panel : Fully wired with all required gadgets and relay boards for mounting PLC, Controller - 1 NO., Analog Input 4 Channel or as required- 1 No., Digital Input 16 Channel - 6 No., Analog Output 2 Channel - 1 No., Digital Output 8 Channel - 6 No., HMI 7" (Parameter display/set-points/operations) - 1 No., Power Supply - 1 No., with full programming code writing, installation and testing executed at the site as per the process flow chart & all as per system requirement.
Supply and fixing of Level Transmitter - Ultrasonic Level Transmitter Supply and fixing of Flote type level Switch - Range 5.0 m Supply and instalation of Flowmeter Magnetic Flow Meter / Dial Gauge ventury flow meter - 65 NB Line , Flow range - 0 - 50.0 m3/hr. Magnetic Flow Meter / Dial Gauge ventury flow meter - 40 NB Line , Flow range - 0 - 50.0 m3/hr. Glass tube Rotameter - Flange type mounting , Flow range 0 - 50 m3/hr. Supply and instalation of quantity meter Quantity meter - 50 NB, indicator and transmitter - For Liquid, Flow range 0 - 50 m3 / hr. Quantity meter - 80 NB, indicator and transmitter - For Liquid, Flow range 0 - 50 m3 / hr. Supply and fixing of Dissolved Oxygen - DO Sensor With Controller, indicator and tranmitter, upto 3.0 m Depth Supply and fixing of Differiatial Pressure Gauge - Differential Pressure Gauge Range : 0 – 1 kg/cm2 "Pressure Gauges - Bourdon Sensing Pressure Gauge ( glycerine filled) Range : 0-10Kg/cm2, It includes pipe fitting with vent valve and drain valve.
Cables - Core cables and Signal cables: 1 Pair/2 Core or as required,1 sq mm/1.5 sq mm Control Room: Cabin with heat insulated or standered panel of size 3 m x 3m x 2.5m with Air-conditioner in control room. The works also including the following Supply and installation of power socket boxes with 5 pin metal clad socket and plug top with 32a cat-c MCB of 4 pole, fixing against wall with suitable support Digital energy meter
Power Cables & Control Cables (FRLS) Supply, installation, testing & commissioning of 1.1 KV grade multicore copper soild/ stranded conductor ,HRPVC insulated, FRLS PVC sheated armoured power & control cable with suitable fixing arragement & accessories as per system requirement & as directed by Engineer-In-Charge (E.I.C.)
Cable Tray Supply & fixing ladder type GI cable trays with vertical sides on both ends and suitable MS supports i.e.channel, beam, angle including concrete bolts, hold fast etc. The scope includes supply of readymade bends, reducers,Tee, covers etc. as required as per instructions of EIC. Note : The scope of work also includes End jointing of above cables by crimping with supply of all jointing materials like solderless tinned copper cable socket, cable glands, gland earthing, insulation tape, flux, duplicate interconnection between gland earthing strip & to the nearest earthing bus terminals as per the drawings, specifications and as per the instructions of the Engineer-in-charge.
Earthing system Supply, installation, testing & commissioning of earthing system ( 2 sets) & associated accessories, etc. complete as per requirements & as per the instructions of E.I.C. Note 1) Measurements of resistance of each earth station & resistance of complete scheme of earthing layout must be measured & recorded 2. Jointing of the earth strip shall be with brass nuts bolts and also with solder joints.
3. Jointing of the earth wire shall be with solder joints with tinned cable sockets GI earth plate electrode 600 x 600 x 6 mm earth station 2.5 m below ground level conforming to IS 3043 complete with all required materials like coke/charcoal, salt, brass nut-bolts & washers, watering arrangement, G.I pipe (B class) masonary chamber, min. 10mm thick chequered plate cover associated materials like 40 x 40 x 5mm angle iron frame work, hinges, locking arrangement etc. & excavation in all types of soil, refilling & removal of excess earth. GI strip/wire fixed to wall/side of trench/ slab/column/beam/shaft with 5mm thick G.I spacers & GI saddles or on existing cable tray with saddles or in ground at 750 mm below including excavation in all types of soil with protective baked bricks, refilling & removal of excess earth within a radius of 500 m temporary reinstatement & back filling of trench, interconnections of earth strip/wire with brass nuts, bolts & washers and solder jointing, painting with two coats of black bituminous compound for earth wire/strip in ground & green enamel paint for earth wire/strip on surface , etc. MOC: 25 x 6 mm GI Strip & 8 SWG copper wire
TOTAL OF PART-B
PART - C - OPERATION & MAINTENANCE OF ETP
Statutory approval for ETP plant Statutory approval/ Permission : Obtaining Statutory approval for above plant from local bodies/ Muncipal corporation, State bodies/ State pollution control board, MOEF and obtaining permissions & clearances for running the plant on regular basis.
Operation & Maintenance of ETP plant Operation & Maintenance of plant : Operation & Maintenance of above plant for one year on 24 x 7 basis in three shift during defect liability period from the date of succesful commissioning & handing over the plant to the Department/ User including deployment of technical manpower (minimum 1 person per shift).
The scope also includes the follwing Note 1: All chemicals required for period of one year including initial charge of chemicals. Note 2: Cost of all chemicals required for NaoCl dosing system & poly dosing system for period of one year including initial charge of chemicals. Note 3: Cost of all chemicals required for acid dosing system, coagulants dosing system, alkali dosing system for period of one year including initial charge of chemicals. Note 4: Cost of Sodium Hypo Chloirde solution ( 5 to 10 % concentration of chlorine) for dis-infecton of treated effluent outlet from ETP plant for period of one year including initial charge of chemicals. Note 5: Disposal of collected oil, grease, floating materials, grit should be disposed off at suitable location within radius of 2 KM at regular intervals as per instruction of E.I.C./ Department. Contractor has to make necessary arrangement at his own cost for disposal with necessary arrangement for transportation, manpower etc..
Testing Of Samples Testing samples & submiting the testing report to Department of raw effluent at bar screen/ Grit chamber inlet ( 01 Sample) & treated effluent from ETP ( 01 Sample) . Sample testing includes the parameters like PH, COD, BOD, TSS, Oil & grease, TDS as mention in Design Basis. Sample should be tested from approved lab like NABET Accredited, MOEF, TPCB or Govt. approved lab as per instruction and as directed by Engineer-In-charge (E.I.C.). Note: One sample for raw sewage & One sample for treated sewage will be count as a one set.
TOTAL OF PART-C
NET TOTAL Part-V-C: 50 KLD ETP at Plot-A
Description of Work / Item(s)
Amount
ABSTRACT FOR PART - I : CIVIL WORK
PART I-A : SUB-STRUCTURE
PART I-B : SUPER-STRUCTURE (STRUCTURAL)
PART I-C : FORM WORK
PART I-D : STEEL REINFORCEMENT WORK
PART I-E : MASONRY WORK
PART I-F : FLOORING WORK
PART I-G : DOORS AND WINDOWS
PART I-H : FITTINGS AND FIXTURES
PART I-I : WATERPROOFING TREATMENT
PART I-J : PLASTERING WORK
PART I-K : PAINTING WORK
PART I-L : MISCELLANEOUS WORK
PART I-M : FACADE WORK
PART I-N : INTERIORS WORK
PART I-O : SIGNAGE WORK
PART I-P : AREA DEVELOPMENT WORK
PART I-Q : TENSILE STRUCTURE
PART I-R : SOFTSCAPE WORK
Description of Work / Item(s)
Amount
PART - I : CIVIL WORK
PART I-A : SUB STRUCTURE
Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and including removal & disposal of rubbish within campus at directed place, area cleaning etc complete all as per specifications and as directed by EIC.
Cutting and felling trees of girth as specified below (measured at a height of 1 m above ground level) including cutting of trunks and branches, removing the roots and stacking of serviceable material and disposal of unserviceable materials within campus at directed place etc complete all as per specifications and as directed by the Engineer-in-charge
Girth beyond 30 cm, up to and including 60 cm girth.
Girth beyond 60 cm, up to and including 120 cm girth.
In all soil other than soft and hard rock
In soft rock
Depth not exceeding 1.5 m from ground level
Depth exceeding 1.5 m & up to 3.0m from ground level
Depth not exceeding 1.5 m from ground level
Depth exceeding 1.5 m & up to 3.0m from ground level
Depth exceeding 3.0 m & up to 4.5m from ground level
Depth exceeding 4.5 m & up to 6.0 m from ground level
Depth exceeding 6.0 m & up to 7.5 m from ground level
Providing and laying in position, at all locations & depths, plain cement concrete of grade as specified below including machine mixing, consolidation, finishing, curing and including cost of form work, shuttering, centering etc. complete all as per specifications and directed by EIC. (Note:- Reinforcement provided if any shall be measured & paid under relevant item.)
Concrete of M10 grade
Concrete of M15 grade
Providing and laying in position, at all levels & loactions, for structural members of all geometrical shape & design as per drawing, Reinforced Cement Concrete (RCC) of grade as specified below, conforming to latest revisions of IS:456-2000 and IS:13920, using 20 mm maximum size aggregates and approved quality sand including admixtures of approved brand and quality (plasticisers / super plasticisers), weigh batching, mechanical mixing, transporting, placing, vibrating, consolidation, finishing, curing etc.complete all as per specifications & as directed by EIC. Please refer Additional Notes. Below Plinth Level ( In Sub Structure)
Reinforced cement concrete of Grade M-25
Reinforced cement concrete of Grade M-30
Reinforced cement concrete of Grade M-35
Extra for providing RMC (Ready Mixed Concrete) conforming to IS:4926 (Latest revision) in lieu of site batch mix RCC & PCC items, supplied by approved RMC manufacturers including transportation, pumping etc.complete all as per specifications and as directed by EIC. Note:- The contractor shall obtain prior approval of RMC manufacturer from Engineer in Charge in writing. The rate shall apply for all levels and locations including all type of structure etc. This item shall be measured in addition to the original items of RCC and PCC of any grade mentioned elsewhere in Schedule of Quantities for sub structure. Please refer Additional Notes.
Providing, erecting, fixing in position, striking / removing and cleaning steel / timber shuttering & centering for form work including single / multiple staging at all floors, level & locations for all geometrical shapes in plain, curved surfaces of structural / R C C elements and including rails, bracings, props, brackets, cutting holes for pipes etc., providing & applying approved form oil on all surfaces of form work coming in contact with concrete including close hacking of all exposed concrete work after removal of form work, all materials, labour etc. complete as per specifications, drawings & as directed by the Engineer-in-Charge. (Area of form work in contact with concrete shall only be measured for payment & stop boards for construction joints etc. will not be measured for payment). Please refer Additional Notes.
For all type of structural / RCC elements including all geometrical shapes and single / multiple staging at all floors and location For Below Plinth Level (In Sub Structure)
Reinforcement for RCC work including supplying, delivering, storing of various diameters as required at site of work including loading, unloading, transporting, decoiling, straightening, cutting, bending, placing in position at all floors, locations & levels and binding with 18 gauge, soft drawn annealed steel binding wire including carrying out various tests as required etc. all as per specifications, drawings & as directed by the Engineer-in-Charge. (Note: The cost of binding wire shall be borne by the contractor and binding wire shall not be measured for payment.)
For Below Plinth Level (In Sub Structure) Thermo Mechanically Treated bars of grade Fe-550 D, manufactured by SAIL, TATA STEEL, JSW, JSPL and RINL only.
Extra over above item for using Thermo Mechanically Treated Bar of grade CRS (Corrosion Resistant Steel) Fe-550 D in place of Thermo Mechanically Treated bars of grade Fe-550 D.
Brick masonry work using well burnt bricks from approved lot of class designation 7.5 (classification as per IS:1077-1992 and min. average compression strength not less than 7.5 N/mm2) using ready mixed cement sand mortar (1.4), to correct line, level and plumb including raking out joints & simultaneous flush pointing using ready mixed cement sand mortar (1.4), curing, scaffolding all as per specifications, drawings and as directed by Engineer in charge. Notes for Masonry Work: 1) The contractor shall get approved the samples of bricks / AAC block from the Engineer-In-Charge before procurement on large scale and shall maintain the same for the entire work. 2) Necessary Openings/ nitches/ pipe sleeves/ cut-outs, wherever required as per drawings and asked for by the Engineer-In-Charge, shall be provided by the contractor without any extra cost. 3) One masonry wall thickness shall be considered as 230 mm and half brick wall as 115 mm and lesser wall thickness if any shall be made up to the required dimensions by the contractor in cement mortar 1:4 (using ready mix mortar) to proper line, level and plumb without any extra cost to the Department. 4) The rate shall include cost of making brick / AAC block masonry to all geometrical shapes and sizes without any extra cost to the Department.
In sub structure (Foundation, plinth, cable pits, trenches, steps etc.)
Providing 15 mm thick Cement plastering work in single coat using ready mixed cement sand mortar (1:4) and finished smooth with neat cement punning, at all levels, locations & depth, over concrete/ masonry surface including surfaces preparation, even & smooth surface in correct line, level, plane, plumb and including scaffolding, curing etc complete all as per specifications and as directed by EIC. (For Inside trenches, Nallah, Pit, Storm water drain, Chambers, steps etc.)
Disposing off the surplus excavated materials beyond initial lead by mechanical transport to the near by dumping pits/ dumping area inside campus including all leads, lifts, loading, unloading, stacking, spreading, levelling etc. complete as per drawings, specifications & as directed by the Engineer in charge. The disposal shall be as per latest guidelines of Construction & Demolition waste management plan as approved by Local Municipal Authority. Royalty for transportation, disposal of earth, spreading etc. including obtaining permission from statutory authority, if any shall be borne by the contractor. Note: Voids @ 20% for soils and 50% for soft rock/ hard rock shall be deducted from fully loaded truck measurements to arrive at the net quantity for payment in case direct measurement is not possible.
230 mm consolidated thickness
150 mm consolidated thickness
Supplying and spreading pesticides chlorpyriphos or other chemical approved by central insecticides board as directed by the manufacturer and spraying the mixture uniformly by sprayer as pre-construction anti-termite treatment at the rate of 7.5 liters per sq.m. on vertical and 5 ltrs. per sq.m. on horizontal surfaces (or as directed by the manufacturer) within the trenches, 50% of the emulsion to be filled in the holes made in trenches at 150 mm. centre to centre etc. complete as per IS 6313 Part-II. (The payment will be made on the basis of plinth area measurement only at ground floor/ stilt area for all stages of operation and vertical face will not be measured for payment) all complete as per specifications, drawings and as directed by the Engineer in charge. Note: a) This item will be executed through approved agency who is a member of Indian Pest Control Association, approved by Central Insecticides Board. b) The contractor shall have to furnish ten years guarantee in the prescribed proforma as per Section-10 (iv) Conditions and clauses of contract-2008, to maintain the anti-termite treated area/ structure free from termite. c) Prior approval of Engineer in Charge shall be obtained after testing the chemical for antitermite to be used and shall be tested in approved laboratory and to be submitted to Engineer in Charge. Cost of testing shall be included in the rates quoted.
Providing and laying damp proof course 38 mm thick at plinth level in cement concrete 1:2:4 using 10 mm. maximum size and down graded stone aggregate, mixed with approved waterproofing compound at 2% by weight of cement laid to levels, slopes etc. including applying a coat of hot bitumen of (grade 80/100) / (VG-10) at 17 kg./10 sq.m. including cost of form work, curing all complete as per specifications & as directed by the Engineer in charge.
Providing and laying patented box type cement based water proofing treatment from outside, by approved water proofing agency for basement, raft, vertical walls, lift well, trenches and other under ground structures during construction etc. at all levels & locations as per specification of the water proofing agency including cleaning of surfaces, curing and testing the basement raft/pit for water tightness, rectification of defects if any, etc. complete as per specification, drawing and as directed by the Engineer-in-charge as per the following. Please refer Additional Notes.
Providing waterproofing treatment on horizontal surfaces for base / floor consisting of i) 1st layer shahabad stone (rough stone slab) of approx. size 600x600x20 mm thick of approved quality over a 25 mm thick base of Ready mixed cement mortar (1:4) mixed with waterproofing compound conforming to IS:2645 in the recommended proportion. Joints shall be sealed and grouted with compound conforming to IS: 2645 in proportions recommended by the manufacturer. ii) 2nd layer of 25mm thick Ready mixed cement mortar (1:4) mixed with water proofing compound in recommended proportions. iii) Finishing top with stone aggregate of 10 mm to 12 mm nominal size spreading @ 8cudm/sqm thoroughly embedded in the 2nd layer.
Providing and laying integral cement based treatment for water proofing on the vertical surface by fixing shahabad stone of approx size 600x600x20 mm thick of approved quality (rough stone slab) with cement slurry mixed with water proofing compound conforming to IS: 2645 in recommended proportion with a gap of 20 mm (minimum) between stone slabs and the receiving surfaces and filling the gaps with neat cement slurry mixed with waterproofing compound and finishing the exterior stone slab with Ready mixed cement mortar (1:4), 20mm thick with neat cement punning mixed with water proofing compound in recommended proportion complete at all levels, locations including scaffolding and as directed by Engineer-in-charge.
Structural steel work at all floors, levels and locations in grills, guard bars for windows, frames, Fence, pit/ trench covers, cover bracket for slanting chajja, trap door, railing, balcony hand railing, hoisting hooks, smoke vents etc. using angles, channels, I-Section, tees, flats, bars, chequered plates, plain plates, hollow section, bright bars etc. of required sizes including supplying, cutting, fabricating, welding, erecting, making holes/ chases wherever required and fixing / embedding in position in concrete/ brickwork/blockwork/ marble/ granite stone with necessary hold fasts/ stainless steel screws & rawl plugs by drilling etc. and finishing the concrete/ brick work/ blockwork after fixing/ embedding including painting two coats of anti corrosive bitumastic paint on all unexposed surfaces and two coats of synthetic enamel paint of approved make and colour on all exposed surfaces over a coat of approved zinc chromate primer etc. complete as per specifications, drawings and as directed by the Engineer in charge. Note:- All structural steel work shall be as per latest version IS:800 & IS:806. All Rectangular and Square Hollow Sections (RHS & SHS) shall be conforming to latest version of IS:4923. All rolled sections shall be of Grade E-250 and conforming to latest verison of IS:2062. Welding shall be as per IS:816 & IS:6227.
Using structural steel sections of specified grade (YSt 240 / 310)
Providing & laying NP-2 class of following diameter RCC hume pipe, conforming to IS:458, in underground for passing of various service lines etc including making holes in masonry/ concrete work wherever required, making good the holes after laying the hume pipe with collar joints using stiff mixture of ready mixed cement mortar (1:4) and sealing open ends with wooden bush etc. all complete as per specifications & as directed by the Engineer-in-charge. (Earthwork, road work and PCC for embedment shall be paid under relevant items)
250 mm dia pipe
450 mm dia pipe
600 mm dia pipe
Total of PART I-A : SUB STRUCTURE
PART I-B : SUPER STRUCTURE (Structural) Note:- Super structure items included in this schedule pertains to all the works above plinth level up to roof level including parapets, water tanks, machine rooms, terrace level works etc unless specified otherwise. Please refer Additional notes.
Providing and laying in position, at all levels & loactions, for structural members of all geometrical shape & design as per drawing, Reinforced Cement Concrete (RCC) of grade as specified below, conforming to latest revisions of IS:456-2000 and IS:13920, using 20 mm maximum size aggregates and approved quality sand including admixtures of approved brand and quality (plasticisers / super plasticisers), weigh batching, mechanical mixing, transporting, placing, vibrating, consolidation, finishing, curing etc.complete all as per specifications & as directed by EIC. Above Plinth Level ( In Super Structure)
Reinforced cement concrete of Grade M-25
Reinforced cement concrete of Grade M-30
Reinforced cement concrete of Grade M-35
Extra for providing RMC (Ready Mixed Concrete) conforming to IS:4926 (Latest revision) in lieu of site batch mix RCC & PCC items, supplied by approved RMC manufacturers including transportation, pumping etc. complete all as per specifications and as directed by EIC. Note:- The contractor shall obtain prior approval of RMC manufacturer from Engineer in Charge in writing. The rate shall apply for all levels and locations including all type of structure etc. This item shall be measured in addition to the original items of RCC and PCC of any grade mentioned elsewhere in Schedule of Quantities for super structure. Please refer Additional Notes.
Total of PART I-B : SUPER STRUCTURE (Structural)
PART I-C : Form Work Notes for form work: a) Area of form work in contact with concrete shall only be measured for payment and stop boards for construction joints will not be measured for payment. b) The rate of form work shall include all type of structural/ RCC elements and geometric shapes including circular and any other curved surfaces. c) For double/ multi stage shuttering design calculations and details / drawings for scaffolding shall be submitted by the contractor well in advance. Prior written approval of formwork shall be obtained from Engineer in Charge, before commencement of work. d) Nothing extra shall be entertained for revision in drawings
Providing, erecting, fixing in position, striking / removing and cleaning steel / timber shuttering & centering for form work including single / multiple staging at all floors, level & locations for all geometrical shapes in plain, curved surfaces of structural / R C C elements and including rails, bracings, props, brackets, cutting holes for pipes etc., providing & applying approved form oil on all surfaces of form work coming in contact with concrete including close hacking of all exposed concrete work after removal of form work, all materials, labour etc. complete as per specifications, drawings & as directed by the Engineer-in-Charge. (Area of form work in contact with concrete shall only be measured for payment & stop boards for construction joints etc. will not be measured for payment).
For all type of structural / RCC elements including all geometrical shapes and single / multiple staging at all floors and location Above Plinth Level (In Super Structure)
Providing, erecting, fixing, in position, striking / removing and cleaning Shuttering & centering, for formwork using ply board (Using Minimum 12 mm thick Shuttering Plywood, conforming to IS:4990) to obtain form finished concrete surfaces of F3 finish to ceilings at all floors, heights, levels & locations including single / multiple staging at all floors and locations for all geometrical shapes in plane, curved surfaces of structural / R C C elements including chamfers, splays, keys, wedges, props, rails,bracings, brackets, cutting hole for pipes etc. providing and applying approved form oil to all surfaces of form work coming in contact with concrete and skirting / removal of the same including finishing by filling form-tie-holes, removal of fins, ridges and irregularities by including all materials labour etc complete as per specifications, drawings and directed by Engineer-in-Charge.
Total of PART I-C : Form Work
PART I-D : Steel Reinforcement work
Reinforcement for RCC work including supplying, delivering, storing of various diameters as required at site of work including loading, unloading, transporting, decoiling, straightening, cutting, bending, placing in position at all floors, locations & levels and binding with 18 gauge, soft drawn annealed steel binding wire including carrying out various tests as required etc. all as per specifications, drawings & as directed by the Engineer-in-Charge. (Note: The cost of binding wire shall be borne by the contractor and binding wire shall not be measured for payment.)
Above Plinth Level (In Super Structure) Thermo Mechanically Treated bars of grade Fe-550 D manufactured by SAIL, TATA STEEL, JSW, JSPL and RINL only.
Total of PART I-D : Steel Reinforcement work
PART I-E : Masonry work Notes for Masonry Work: 1) The contractor shall get approved the samples of bricks / AAC block from the Engineer-In-Charge before procurement on large scale and shall maintain the same for the entire work. 2) Necessary Openings/ nitches/ pipe sleeves/ cut-outs, wherever required as per drawings and asked for by the Engineer-In-Charge, shall be provided by the contractor without any extra cost. 3) One masonry wall thickness shall be considered as 230 mm and half brick wall as 115 mm and lesser wall thickness if any shall be made up to the required dimensions by the contractor in cement mortar 1:4 (using ready mix mortar) to proper line, level and plumb without any extra cost to the Department. 4) The rate shall include cost of making brick / AAC block masonry to all geometrical shapes and sizes without any extra cost to the Department.
Total of PART I-E : Masonry work
PART I-F : Flooring work Please refer Additional Notes.
Providing and laying machine cut and machine polished Kotah stone flooring, skirting, riser, treads at all floors, levels & location including cement mortar (using ready mix mortar) bedding / backing, close jointed & grouted with matching cement slurry and finished to line, level, curing etc. as required, including cutting of stone slab, wastage, making cut outs, wherever required, machine polishing/ hand polishing (where machine cannot have access) and including providing and laying 6 mm thick POP during construction period etc. complete all as per specifications, drawings and as directed by the Engineer in charge.
In flooring with mirror polished, 25 mm minimum thickness kotah stone slab of size 600mm x 600mm / 575mm x 575mm / (and any other size and pattern as per drawing) laid over bedding of 20 mm Ready mix mortar having Cement: Sand (1:4)
In staircase treads with mirror polished, 25 mm minimum thickness kotah stone slab in single piece upto 2.1 m length laid over bedding of 20 mm. thick Ready mix mortar having Cement: Sand (1:4), including half round moulding & polishing of nosing for exposed face, making three anti skid grooves (5 mm wide & 2 mm deep at 25 mm C/C)
In riser with mirror polished, 20 mm minimum thick kotah stone in single piece up to 2.1 m length, fixed over bedding of 12 mm thick Ready mix mortar having Cement: Sand (1:4)
Providing and laying machine cut River Washed Kotah stone flooring, skirting, riser, treads at all floors, levels & location including cement mortar (using ready mix mortar) bedding / backing, close jointed & grouted with matching cement slurry and finished to line, level, curing etc. as required, including cutting of stone slab, wastage, making cut outs, wherever required, and including providing and laying 6 mm thick POP during construction period etc. complete all as per specifications, drawings and as directed by the Engineer in charge.
In flooring with 25 mm minimum thickness River Washed kotah stone slab of size 600mm x 600mm / 575mm x 575mm / (and any other size and pattern as per drawing) laid over bedding of 20 mm Ready mix mortar having Cement: Sand (1:4)
In staircase treads with 25 mm minimum thickness River washed kotah stone slab in single piece upto 2.1 m length laid over bedding of 20 mm. thick Ready mix mortar having Cement: Sand (1:4), including half round moulding & polishing of nosing for exposed face, making three anti skid grooves (5 mm wide & 2 mm deep at 25 mm C/C)
In riser with 20 mm minimum thick River Washed kotah stone in single piece up to 2.1 m length, fixed over bedding of 12 mm thick Ready mix mortar having Cement: Sand (1:4)
Providing & laying machine cut & machine polished (mirror finish) 18mm thick Granite Stone of Steel Grey /Sadarhalli / Z Brown / Brown or other approved colour at all floor & location in necessary cement mortar bedding /backing, close jointed & grouted with matching cement slurry and rounding of edges, finished to line, level,curing etc. as required, including cutting of stone slab, wastage, making cut outs, grooves wherever required, machine polishing/ hand polishing (where machine cannot have access) etc. complete all as per specifications, drawings and as directed by the Engineer in charge. Note: Top exposed surface on plan &exposed vertical finished face shall be measured for payment in Sqm. Note:- 1) All finished natural stone except for flooring & Platform shall be applied with aralide or equivalent stone adhesive on back surface,spreading/splashing of sand particles on adhesive applied surface before a day of fixing of stones. 2) Window jamb, cill & lintel bottom with granite / green marble shall be mitred / partly mitred joint as directed by Eingineer-In-Charge. 3)Exposed inside vertical finished face of window below platform shall be measured for payment in sqm. 4)Agencies shall quote rate accordingly.
In flooring with machine polished Granite stone of size 800mm x 800mm/ 1000mm x 1000mm / (and any other size and pattern as per drawing) laid over & including 20mm thick cement mortar1:4 ( 1 cement : 4 coarse sand) bedding. (Using ready mix mortar) including cement slirry at 4.40 Kg/Sqm over bedding and matching slurry with white cement at 2.20 Kg/Sqm for grouting the joints.
18 mm thick one side machine polished granite stone of approved colour, shade and surface finish for cladding/ dado/skirting/lift jamb /Facia with stone slabs of various sizes in pattern including 12 mm thick 1:4 cement mortar (Using ready mix mortar) backing, fixing of 6mm (approx.) size angular stone chips to the backside of granite after applying araldite to the unpolished surface of the granite to create a surface suitable for proper bond with backing and filling the space between granite and backing with cement slurry including adequate curing etc. complete as directed and including rounding & polishing the exposed edges in semicircle / chamfering / or as per drawing & as ditected.
18 mm thick machine cut and single side machine polished Granite stone of approved colour & shade in stepped form laid over 20 mm thick 1:4 cement mortar (Using factory made Ready Mix Mortar only) including half round moulding & polishing of exposed face etc complete. (for window cill)
For top of dwarf walls, parapets, seat wall, planter wall etc using machine polished Granite stone of approved colour, shade & size as per drawing laid over & including 20mm thick cement mortar1:4 ( 1 cement : 4 coarse sand) bedding. (Using ready mix mortar) including cement slirry at 4.40 Kg/Sqm over bedding and matching slurry with white cement at 2.20 Kg/Sqm for grouting the joints. including half round / semi circle / camfering moulding & polishing of exposed face etc complete.
Providing & laying machine cut & River washed finish 30 mm thick Granite Stone of Steel Grey / Sadarhalli / Brown or other approved colour at all floor & location in necessary cement mortar bedding /backing, close jointed & grouted with matching cement slurry and rounding of edges, finished to line, level,curing etc. as required, including cutting of stone slab, wastage, making cut outs, grooves wherever required, machine polishing/ hand polishing (where machine cannot have access) etc. complete all as per specifications, drawings and as directed by the Engineer in charge. Note: Top exposed surface on plan &exposed vertical finished face shall be measured for payment in Sqm.
In flooring with River wash finished Granite stone of size 800mm x 800mm/ 1000mm x 1000mm / (and any other size and pattern as per drawing) laid over & including 20mm thick cement mortar1:4 ( 1 cement : 4 coarse sand) bedding. (Using ready mix mortar) including cement slirry at 4.40 Kg/Sqm over bedding and matching slurry with white cement at 2.20 Kg/Sqm for grouting the joints.
18 mm thick one side River wash finished granite stone of approved colour, shade and surface finish for dado/skirting/Riser stone slabs of various sizes in pattern including 12 mm thick 1:4 cement mortar (Using ready mix mortar) backing,
Providing & laying at all floors & locations Homogeneous Full body Vitrified tile/ Glazed vitrified tile/ Anti Skid Vitrified tileVitrified tile double charge/ multi charge (Glossy /Matt/ Satin)/ approved manufacturers of sizes 600 mm X 600mm / 800mm X 800mm / 1000 mm X 1000 mm size or as per approved size and having mimimum thickness 8.5 mm or as specified by approved manufacturer tiles conforming to IS:15622 having water absorption less than or equal to 0.08% (Group B I a), in flooring/ skirting/ dado/ cladding / staircase tread/ riser at all floors and location, heights/ levels and lead in approved pattern and colour, shade laid over cement mortar bedding/ backing/ adhesive backing, including cleaning and preparing the surface for bedding/backing, spreading the neat cement slurry, close jointed and grouted with matching coloured readymade cement grout and approved pigment as per manufacturer's specifications, finished to level, line, slope and plumb, cutting of tiles, wastage, making openings / cut out if neccesary, final cleaning of surfaces, curing etc. all as per drawings, specifications & as directed by Engineer in charge. Please refer Additional Notes.
In flooring using Double Charged vitrified tile polished Finish of size 600 mm X 600 mm laid over 20 mm thick cement mortar1:4 bedding (using reday mix mortar) and spreading neat cement slurry by using minimum cement about 2 kg/sqm prior to bedding and spreading cement paste using minimum cement of about 4.50 kg/sqm over bedding, and including Providing and laying Durafloor protector XF 3 mm thick sheet of approved make and brand over the whole vitrified tile / stone flooring area along with removing and cleaning the same before handing over without damaging the finished surface & making good the damages, if any etc and including Providing in flooring & skirting 3 mm thick and 8.5 mm deep grout line using PVC spacers for creating true alignment and gap between vitrified tile work, if shown in the drawing & the 3 mm spacer joints filled with approved cement based tile grout including all labour material, wastage complete.
In flooring using Glazed vitrified tile Matt / Anti Skid Finish of size 600 mm X 600 mm laid over 20 mm thick cement mortar1:4 bedding (using reday mix mortar) and spreading neat cement slurry by using minimum cement about 2 kg/sqm prior to bedding and spreading cement paste using minimum cement of about 4.50 kg/sqm over bedding,, and including Providing and laying Durafloor protector XF 3 mm thick sheet of approved make and brand over the whole vitrified tile / stone flooring area along with removing and cleaning the same before handing over without damaging the finished surface & making good the damages, if any etc and including Providing in flooring & skirting 3 mm thick and 8.5 mm deep grout line using PVC spacers for creating true alignment and gap between vitrified tile work, if shown in the drawing & the 3 mm spacer joints filled with approved cement based tile grout including all labour material, wastage complete.
In dodo / skirting / cladding / sloped skirting laid over 12 mm thick CM 1:4 (1 cement : 4 sand, using reday mix mortar) backing, including providing grooves as per drawing on top of skirting. ( Using Double charge vitrified tiles)
In dodo / skirting / cladding / sloped skirting laid over 12 mm thick CM 1:4 (1 cement : 4 sand, using reday mix mortar) backing, including providing grooves as per drawing on top of skirting. (Using Homegeneous Full body vitrified tiles)
In flooring using Homogeneous full body vitrified tile of size up to 1200 mm X 2400 mm laid over 20 mm thick cement mortar1:4 bedding (using reday mix mortar) and spreading neat cement slurry by using minimum cement about 2 kg/sqm prior to bedding and spreading cement paste using minimum cement of about 4.50 kg/sqm over bedding, and including Providing and laying Durafloor protector XF 3 mm thick sheet of approved make and brand over the whole vitrified tile / stone flooring area along with removing and cleaning the same before handing over without damaging the finished surface & making good the damages, if any etc and including Providing in flooring & skirting 3 mm thick and 8.5 mm deep grout line using PVC spacers for creating true alignment and gap between vitrified tile work, if shown in the drawing & the 3 mm spacer joints filled with approved cement based tile grout including all labour material, wastage complete.
Providing and fixing over smooth base flooring with PUF sheet cushioning factory made, pre-polished 15 mm thick solid wood Parquet flooring of approved herringbone or distinct pattern, shade & texture and sizes (width:130-170 & length 600-2000mm), at all levels, locations, floors including all labour and accessories required for installation etc. complete as per specification and as per direction of Engineer-in Charge.
Providing laying and fixing in position at all floors and levels machine cut, machine polished approved colour Dholpur sand stones of following thickness of approved quality and shade for flooring, skirting, cladding, treads , risers, window & lift jamb /cills, etc. on brick concrete surface etc., of required sizes fixed over and including necessary mortar bedding/ backing coat, close jointed and grouted with matching cement slurry mixed with suitable pigments including providing & fixing suitable & approved stainless steel cramps / pins at suitable intervals and approved adhesive such as araldite to ensure fixing of stone securely including making necessary recess in the stone to accommodate the hold cramps / pins and approved quality adhesives to ensure the fixing of stone securedly grouting the joints with approved pigments, curing, cleaning and final hand polishing etc. complete all as per specifications, drawings and as directed by Engineer in Charge.
In wall cladding with polished dholpur stone of approved colour and shade laid / fixed over and including 12 mm thick cement mortar 1:4 (1 cement : 4 sand, using reday mix mortar) including rounding in semicircle / chamfering the exposed edges, grouting the joints with approved pigments etc. complete as per specification, drawing and as directed by the Engineer in Charge.
Providing & laying machine cut machine polished natural stones as mentioned for the followings for kitchen / Basin platform topping, counter topping and facia over and including necessary cement mortar for backing / bedding, close jointed and grouted with matching cement slurry and finished to line, slope, level, plumb, curing etc, as required including cutting of stone slabs, wastages, making cut outs wherever required etc all as per specifications and as directed by the Engineer in charge. Notes : 1) Verticals, shelves, platform shall be embedded minimum 25 mm in wall/ flooring. 2) Top exposed surface on plan & exposed vertical finished face shall be measured for payment in sqm.
For kitchen / Basin platform top, Vertical support for Counter, upto 750 mm wide and maximum length upto 1.80 m in single piece consisting machine cut machine polished 35 mm thick cuddappah stone at bottom and mirror polished machine cut 18mm thick Jet black/ approved Granite stone at top fixed with 47 mm thick 1:3 cement mortar (Using ready mix mortar), between two stone slabs (Double stone slab sandwitch type) including providing cut out if any, moulding and polishing the edges etc complete.
For kitchen platform horizontal & vertical facia upto100 mm wide machine cut machine polished on one side 18 mm thick Jet black/ approved Granite stone fixed with epoxy resin base (Araldite adhesive orequivalent) including round moulding and polishing the edges etc complete.
Providing & laying interlocking mat made of JSR (Japenese Synthetic Rubber) in size (1m X 1m) having thickness 30 mm manufactured by approved manufacturer, in approved colour, pattern, design and shade, mat made of 100% fresh material, light weight and comfortable for gym area, easy to clean, water resistant, non-slippery surface etc complete all as per specifications and as directed by EIC.
Providing & fixing Glass Mosaic tiles on finished wall surface of size (20 mm X 20 mm X 4 mm / 25 mm X 25 mm X 4 mm) in approved colour, shade, pattern, design and of approved manufacturer and including providing & fixing with approved adhesive applied at the rate of 2.5 Kg/Sqm (or as per manufacturer's specifications), grouting, finishing etc complete all as per specifications and as directed by the Engineer-in-Charge.
Providing and fixing removable raised/false access flooring with system and its components of approved make for different plenum height with possible height adjustment upto 50 mm, comprising of modular load bearing floor panels supported on G.I. rectangular stinger frame work and G.I. Pedestal etc. all complete, as per the architectural drawings, as specified and as directed by Engineer-in-charge consisting of: (a) Providing at required spacing to form modular framework, pedestalsmade out of GI tube of thickness minimum 2 mm and 25 mm outer diameter, fully welded on to the G.I. Base plate of size 100mm x 100mm x 3mm at the bottom of the pedestal tube, G.I. pedestal head of size 75mmx75mmx3.5 mm welded with GI fully threaded stud 16mm outer diameter with two GI Check nuts screwed on the stud for level adjustment upto 50mm, locking and stabilizing the pedestal head in position at the required level. The pedestals shall be fixed to the subfloor (base) through base plate using epoxy based adhesive of approved make or the machine screw with rawl plug.
(b) Stringers system in all steel construction hot dipped galvanized ofrectangular size 570x20x30x0.80mm thick having holes at both ends for securing the stringers on to the pedestal head using fully threaded screws ensuring maximum lateral stability in all directions, the grid formed by the pedestal and stringer assembly shall receive the floor panel, this system shall provide adequate solid, rigid support for access floor panel, the system shall provide a minimum clear uninterrupted clearance between the bottom of the floor for electrical conduits and wiring etc. all complete as per the architectural drawings, as specified and as directed by the Engineer-in-charge.
(c) Providing and fixing Access Floor panel of 600x600x32 mm mediumgrade Filled Steel anti static high pressure Lamination of 800H grade (FS800H). Access Floor panel shall be steel welded construction with an enclosed bottom pan with uniform pattern of 64 hemispherical cones. The top and bottom plates of Steel Gauges: top 0.6 mm and bottom 0.7 mm fused spot welded together (minimum 64 welds in each dome and 20 welds along each flange). The panel should be Corroresist epoxy coated for lifetime rust protection and cavity formed by the top and bottom plate is filled with Pyrogrip noncombustible Portland cementitious core mixed with lightweight foaming compound. The access floor shall be factory finished with Anti-static High Pressure laminate with Non Warp technology upto 1mm thickness for superior adhesion and Surface flatness within 0.75mm.The panel is to withstand a Concentrated Load of 363 kgs applied on area 25mm x 25mm without collapse in the centre of the panel which is placed on four steel blocks. The panel will withstand and Uniformly Distributed Load (UDL) minimum 1250 kg/sqm and an impact load of 50kg all complete as per the approved manufacturers specification and as per the direction of Engineer-in-charge. All specification must be printed on the side of the panel to ensure the quality of the product.
450 mm Finished Floor Height (FFH).
Total of PART I-F : Flooring work
PART I-G : Doors and windows Please refer Additional Notes.
Providing second class teak wood work in frames of doors, windows, clear story openings and other frames, wrought framed and fixed in position of required size and shape including sawing, jointing, making rebates for shutters, making grooves as shown in the drawings, finishing the surfaces to the required finish all as per specifications and drawings including necessary MS hold fasts 40 mm X 3 mm thick, 200 mm long / with coach screws including protective painting to the suface that will come in contact with walls, joining materials, labour and including polishing with two coats of french spirit polish over a coat of wood filler to form uniform neat finish of approved make and shade. etc. complete all as per specifications and as directed by the Engineer-in-charge.
Supplying & fixing in position the following type solid core block board flush door shutter (Single/ double leaf) with commercial ply facing / prelamination on both sides conforming to IS 2202 (Part-1) of approved make & brand with external / internal type second class teak wood lipping alround of required width and depth (20 minimum thickness all around) of shutter as per IS/as specified, fixing shutters in position to HMPS door frames/ wooden frames/ granite frame works (door frames shall be paid separately under relevant item) at all floors by cutting/ planing if necessary including labour for fixing of the fittings & fixtures as per drawing with wooden packing pieces if necessary (but excluding the cost of fittings and fixtures with SS screws which shall be paid separately under relevant item), including view panel wherever required as per drawing, finishing as specified all as per specifications, drawings and as directed by Engineer In Charge.
35 mm thick flush door shutter, With 1.0 mm thick decorative laminate sheet of approved colour, pattern & shade fixed on both faces of shutter
30 mm thick flush door shutter (for shaft doors), With 1.0 mm thick decorative laminate sheet of approved colour, pattern & shade fixed on one face of shutter and 1.0 mm thick white / off white lamination on another face.
Wooden Fire Rated Doors with Wooden Frames. Fire Resistant Door (FRD) assembly having 120 minutes (2 hr) Fire rating, Non-Metallic and conforming to IS 3614:2021 (Single / Double lef Shutter) Providing and fixing factory made Fire rated door assembly of wooden door frame with non mettallic single leaf door shutter with accessories, the entire door assembly including shutter, frame and fittings shall be confirming to 120 minutes (2 hr) fire rating as per IS 3614. Frame:- The door frame shall be made of second class teak wood. The frame shall be of grooved profile of minimum size 90 × 60 mm with inbuilt sealing system to take appropriate fire rated smoke seal. Frame shall be provided with appropriate reinforcement suitable for hardware and flush fixing. Frames shall be provided with stiffener pieces and mitred cut joints (self tab/screwed assembled at site). Fire rated EPDM smoke seal, confirming to IS 3614 : 2021 shall be fixed within the inbuilt groove or stuck with adhesive on the entire perimeter of the frame. Door frames shall be fixed to all round the opening with minimum 8 mm dia CSK headed fastner of minimum 80 mm long with 8mm dia Polyamide sleeves @ 3 Nos at each side.
Finishing: Frame to be factory finished with fire rated french spirit polish of approved colour and shade all complete as per manufacturer’s Specification and direction of the engineer in charge. Door Shutter: The factory made fire resistant non mettallic wooden solid minimum 45 mm thick single leaf shutter of size (900 X 2350 mm / 1200 X 2350 / 750 X 1500 mm etc ), asbestos free with P&F vision panel of size (as per drawing) with fire rated glass & accessories. Accessories Hardware: Fire doorset shall include all accessories like, Fire rated SS 304 grade ball bearing type hinges of minimum size 100 mm ×75 mm × 3 mm one (3 numbers per leaf upto 2100 mm height or as per test evidence), one number fire rated SS mortise lock with handle, fire rated door closer, fire intumescent seal, "Installation: Post installation space / gap of door frame shall be filled with fire rated self-extinguishing type polyurethane foam. Rate shall include for supply and installation of complete door assembly, by the manufacturer. (All mechanical and functional hardware like hinges, lever handles, door closers with fire rating are to be used on doors and must conform to relevant IS 3614 : 2021.
all as per manufacturer's specification and providing Fire Resistant certification (manufacturing & installation) as required by local fire statutory authority shall be furnished by manufacturer of Door assembly (Frame, Shutter, fitting) and all cutting/ planning if necessary, labour for fixing the fittings and fixtures with suitable packing if necessary including providing and fixing 120 minutes (2 hr) fire rated approved shade lamination on both side of shutter (preferably teak wood colour) etc. all complete all as per specifications, drawings & as directed by Engineer in charge.
Wooden Fire Rated Doors with HMPS Steel Frames. Fire Resistant Door (FRD) assembly having 120 minutes (2 hr) Fire rating, Non-Metallic and conforming to IS 3614:2021 (Single / Double lef Shutter) Providing and fixing factory made Fire rated door assembly of galvanised Iron Steel door frame with non mettallic single leaf door shutter with accessories, the entire door assembly including shutter, frame and fittings shall be confirming to 120 minutes (2 hr) fire rating as per IS 3614. Frame:- The door frame shall be made of minimum 1.20 mm thick GI Sheet with minimum 120 GSM coating as per IS:277. The frame shall be of grooved profile of minimum size 90 × 60 mm with inbuilt sealing system to take appropriate fire rated smoke seal. Frame shall be provided with appropriate reinforcement suitable for hardware and flush fixing. Frames shall be provided with stiffener pieces and mitred cut joints (self tab/screwed assembled at site). Fire rated EPDM smoke seal, confirming to IS 3614 : 2021 shall be fixed within the inbuilt groove or stuck with adhesive on the entire perimeter of the frame. Door frames shall be fixed to all round the opening with minimum 8 mm dia CSK headed fastner of minimum 80 mm long with 8mm dia Polyamide sleeves @ 3 Nos at each side.
Finishing: Frame to be factory finished with polyester powder coating of minimum thickness of 30 microns (500 hrs salt spray test) of approved colour and shade all complete as per manufacturer’s Specification and direction of the engineer in charge. Door Shutter: The factory made fire resistant non mettallic wooden solid minimum 45 mm thick single leaf shutter of size (900 X 2350 mm / 1200 X 2350 / 750 X 1500 mm etc ), asbestos free with P&F vision panel of size (as per drawing) with fire rated glass & accessories. Accessories Hardware: Fire doorset shall include all accessories like, Fire rated SS 304 grade ball bearing type hinges of minimum size 100 mm ×75 mm × 3 mm one (3 numbers per leaf upto 2100 mm height or as per test evidence), one number fire rated SS mortise lock with handle, fire rated door closer, fire intumescent seal,
Installation: Post installation hollow space within door frame shall be filled with fire rated self-extinguishing type polyurethane foam. Rate shall include for supply and installation of complete door assembly, by the manufacturer. (All mechanical and functional hardware like hinges, lever handles, door closers with 120 minutes fire rating are to be used on doors and must conform to relevant IS 3614 : 2021. all as per manufacturer's specification and providing Fire Resistant certification (manufacturing & installation) as required by local fire statutory authority shall be furnished by manufacturer of Door assembly (Frame, Shutter, fitting) and all cutting/ planning if necessary, labour for fixing the fittings and fixtures with suitable packing if necessary including providing and fixing 120 minutes (2 hr) fire rated approved shade lamination on both side of shutter (preferably teak wood colour) etc. all complete all as per specifications, drawings & as directed by Engineer in charge.
Steel Fire Rated Doors with HMPS Steel Frames. Fire Resistant Door (FRD) assembly having 120 minutes (2 hr) Fire rating, Metallic and conforming to IS 3614:2021 (Single / Double lef Shutter) Providing and fixing factory made Fire rated door assembly of galvanised Iron Steel door frame with mettallic single / double leaf door shutter with accessories, the entire door assembly including shutter, frame and fittings shall be confirming to 1200 minutes (2 hr) fire rating as per IS 3614. Frame:- The door frame shall be made of minimum 1.20 mm thick GI Sheet with minimum 120 GSM coating as per IS:277. The frame shall be of grooved profile of minimum size 90 × 60 mm with inbuilt sealing system to take appropriate fire rated smoke seal. Frame shall be provided with appropriate reinforcement suitable for hardware and flush fixing. Frames shall be provided with stiffener pieces and mitred cut joints (self tab/screwed assembled at site). Fire rated EPDM smoke seal, confirming to IS 3614 : 2021 shall be fixed within the inbuilt groove or stuck with adhesive on the entire perimeter of the frame. Door frames shall be fixed to all round the opening with minimum 8 mm dia CSK headed fastner of minimum 80 mm long with 8mm dia Polyamide sleeves @ 3 Nos at each side.
Finishing: Frame to be factory finished with polyester powder coating of minimum thickness of 30 microns (500 hrs salt spray test) of approved colour and shade all complete as per manufacturer’s Specification and direction of the engineer in charge. Door Shutter: The factory made fire resistant mettallic door leaf shall be minimum 60 mm thick fully flush double skin step design door, insulated with or without vision. Door leaf shall be manufactured from 1.2 mm (18guage) minimum thick galvanised steel sheet. The internal construction of the door should be rigid reinforcement pads for receiving appropriate hardware. The infill material shall not be less than be 120kg/m3 high density mineral wool insulation material. Intumescent seals 15 x 1.5mm to be provided. All ISI labelled doors shall be factory prepped for receiving appropriate hardware and provided with necessary reinforcement for hinges, locks, and door closers panic bar etc. The edges should be interlocked with a bending radius of 1.4mm. For pair of doors integrated astragals has to be provided on the meeting stile for both active and inactive leaf. Vision lite wherever applicable shall be maximum 200 x 450mm with clear borosilicate fire rated glass of 6mm. Glass shall be fixed with suitable gasket and with clip-on arrangement..
The door leaf shall be factory finished with polyester powder coating of minimum thickness of 30 microns (500 hours of salt spray test) of approved colour and shade all complete as per manufacture's Specification and as per the directions of Engineer - in- charge. Accessories Hardware: Fire doorset shall include all accessories like, Fire rated SS 304 grade ball bearing type hinges of minimum size 100 mm ×75 mm × 3 mm one (3 numbers per leaf upto 2100 mm height or as per test evidence), one number fire rated SS mortise lock with handle, fire rated door closer Installation: Post installation hollow space within door frame shall be filled with fire rated self-extinguishing type polyurethane foam. Rate shall include for supply and installation of complete door assembly, by the manufacturer. (All mechanical and functional hardware like hinges, lever handles, door closers with 120 minutes fire rating are to be used on doors and must conform to relevant IS 3614 : 2021.
all as per manufacturer's specification and providing Fire Resistant certification (manufacturing & installation) as required by local fire statutory authority shall be furnished by manufacturer of Door assembly (Frame, Shutter, fitting) and all cutting/ planning if necessary, labour for fixing the fittings and fixtures with suitable packing if necessary including providing and fixing 120 minutes (2 hr) fire rated approved powder coated steel door set etc. all complete all as per specifications, drawings & as directed by Engineer in charge.
Wooden Acoustic Doors & frame system: Providing & fixing non mettalic acoustic door shutter (minimum 35 mm thick) with non mettalic frame of minimum size (90 X 60 mm). The non mettalic shutter consists of minimum 6 mm thick, 2 nos. non combustible board, sandwiching acoustic insulation filler, faced with 6 mm thick ply and 1 mm thick approved colour & shade lamination on both sides, Hard wooden lipping all around the shutter, including providing & fixing Acoustic seals for sound reduction properties, SS ball bearing hinges of size 100x75x3mm, locking arrangments with handle & lock, and including providing & fixing all acoustic seals, necessary fittings, fixtures, finishing of door frame surface etc complete all as per specifications and as directed by the Engineer-in-Charge.
Providing & fixing Hollow Metal Pressed steel (HMPS) door frames of following profile fabricated out of 1.60 mm thick G.I sheet of coating (Class VIII of zinc coating) 120 gram/sqm, manufactured by Sail / Lloyds/ Jindal or equivalent of profiles / size generally conforming to IS 4351-2003 with suitable one/two set rebates for fixing shutters and also rebate suitable for fixing fixed glazing including hole for self tapping screws wherever shown in the drawing, each frame to contain hinge jamb, lock jamb and head all rigidly fixed together with welded /mechanical joints with back plates /angles to correct shape & angles including providing and fixing base ties with GI channel 50x25mm, 1.25mm thick suitable section to suit floor thickness / angle thresholds with MS angle 25x25x3mm, 6nos. of adjustable lugs per frame, providing and welding of 40x40x5mm,150mm long angle cleats for hinges with necessary tapped holes for fixing counter sunk headed machine screws to suit heavy duty oxidised / stainless steel hinges of size 125mm x 65mm x 2.8mm/125mm x 76mm x 2.80mm/ 100mm x59mm x2.6mm/75mm x 48mm x 2.45mm or shop type welding and self taping screw for fixing hinges/ piano hinges etc. and finishing the same to smooth etc. (but excluding the cost of hinges which shall be paid under the relevant item) including providing each door frame with necessary lock strike plates, mortar guards, buffers, bushes etc. required
Profile 90mm x 60 mm with single rebate for doors.
Scientific / Clean Room Door Shutter & frame system Non Fire Rated : Providing & fixing Hollow metal clean room doors as per IS 4351 & IS 16074 made of pressed stainless steel. Frame: Door frame shall be single rebate grooved profile of size 125 x 55 mm made out of minimum 1.2 mm (18 gauge) thick stainless steel sheet. Frames shall be mitered and field assembled with self-tabs. Frames to have in build grooved sealing system and shall be site fitted with PVC seal as standard. All provision should be mortised, drilled and tapped for receiving appropriate hardware. Frames should be provided with back plate bracket and anchor fasteners for installation on a finished plastered masonry wall opening. Frames shall be filled with non-fire rated puff and the gaps shall be filled with backer rod & silicon sealant.
Shutter: Door leaf shall be 46 mm thick fully flush double skin door, with or without vision lite. Door leaf shall be manufactured from minimum 0.8 mm (22 gauge) thick tainless steel sheet. The internal construction of the door should be rigid reinforcement pads for receiving appropriate hardware. The infill material shall be resin bonded honeycomb core. All doors shall be factory prepped for receiving appropriate hardware and provided with necessary reinforcement for hinges, locks, and door closers. The edges should be interlocked with a bending radius of 1.4 mm. For pair of doors integrated astragals has to be provided on the meeting stile for both active and inactive leaf. Vision lite wherever applicable should be double glazed flush fixed in line with shutter as per manufacturers recommendation. Vision glass: Doors shall be with vision glass as a part of complete door assembly. The glass should be 4 mm clear toughened double glazed unit flush fixed with sealant on the surface of the door. Finish: All doors and frames shall be finished Pure Polyester Powder coated and shall have passed minimum 500 hours of salt spray test, etc complete all as per specifications and as directed by the Engineer-in-Charge.
Providing and fixing following type of approved quality glass panes for doors/ windows/ ventilators/ louvers, of approved manufacturer and fixing with frame work including fixing and providing and fixing with necessary teak wood beading of size 10 mm X 20 mm / cleats etc necessary SS screws etc, all complete generally as per drawings specifications and as directed by the Engineer-in-charge. Note:- Only clear opening of glass shall be measured for payment.
Vision panel in wooden door shutter using 6 mm thick toughened clear float glass
Vision panel in Steel door shutter using 6 mm thick toughened clear float glass
SS KICK PLATE: Providing and fixing SS 304 grade 1.2 mm thick kick plate of required size disable toilet door/ kitchen door as drawing of approved make including fixing with necessary material like adhesive, adhesive tape, SS screws etc complete as directed by engineer in charge. Kick plate have cute corner and grinded edges as per approved sample. Max. Height of Kick Plate to be 600mm and max. door width shall be as per drawing/site requirement.
Fixed Glass panels:- Providing and fixing at all levels & locations, 10 mm thick clear glass pane having 120 minutes (2 Hr) fire rating manufactured by approved manufacturer and fixing with steel/wooden door frame work including providing and fixing with necessary teak wood beading of size 10 mm X 20 mm / MS cleats etc necessary SS screws etc, all complete generally as per drawings specifications and as directed by the Engineer-in-charge. Note:- Only clear opening of glass shall be measured for payment.
Aluminium Framed Doors: Providing, supply, fabrication, installing, fixing, testing, cleaning, protection and handing over the single & double shutter Aluminium framed doors system, at all levels, locations, floors as per approved drawings including all labour, material, wastage, transporation, fixing in position, scaffolding etc complete all as per specifications, drawings and as directed by the Engineer-in-Charge. The Aluminium framed doors system shall with stand the wind pressure of confirming to IS -875 part III. The Aluminium framed doors system shall have two barrier gasket system for weather sealing at bottom. The system shall have necessary arrangments for three leaf projected type hinges, locking cylinder, SS-316 grade H type handles, door closure, tower bolts. Including providing & fixing microwave cured EPDM gasket, non staining weather sealant, SS-304 grade pan head screws etc complete.
Supplying and fixing in position at all floors, levels & locations, aluminium section [extruded] for aluminium framed doors as per drawing of approved manufactures with extruded sections of Jindal / Indal / Aluminax or other approved eqivalent sections with size and weights as shown in the drawing (door shutter profile shall be suitable to accommodate 6 mm SGU & 24 MM DGU glass), for frames and shutters [including wastages if any] conforming to relevant I.S specifications, including providing and fixing aluminium channel beading / glazing clips fixed with necessary matching anodised screws, grouting the gap with thermocole & polysulphide sealant, 9 mm thick brushseal at bottom shutter etc. all complete generally as per drawings, specifications etc., all as directed by Engineer in charge, but excluding the cost of glazing, which will be paid separately. (The aluminium system consist of the extruded aluminium sections of alloy 6063 T5/T6 & tolerances confirming to DIN / EN standards from approved make and manufacturer. The aluminium sections shall have approved shade and colour super durable powder coating with minimum 50 micron thickness. The non visible aluminium sections shall have approved chromatizing treatment. {The weight of extruded aluminium sections only will be mesured for payment}). (For Aluminium Single and Double shutter)
Providing, Supplying, assembling & installing at all levels, locations & floors, hermatically sealed 6-12-6 mm double glazed vision panel units of approved make comprising of an outer heat strengthened float glass 6 mm thick, of approved colour and shade with reflective soft coating on surface # 2 of approved colour and shade, an inner heat strengthned clear float glass 6 mm thick, spacer tube 12mm wide, dessicants, with moisture absorbing compound (silica gel) including primary seal and secondary seal (structural silicone sealant), refelective coating like Metallic Blue glass / Sterling Silver or Green or other approved equivalent shade, T&P, scaffolding and other incidental charges, wastages etc all complete as per approved shop drawings and specifications and as directed by the Engineer-in-Charge. (Note:- Doubled glazed fixed vision panels shall be measured to the overall dimension on external face as fixed on site (Actual size). For payment, only the actual area of glass on face # 1 of the glass panels (excluding the areas of the grooves and weather silicone sealant) provided and fixed in position, shall be measured in sqm.
Providing and fixing following type of approved quality glass panes for aluminium sliding windows, of approved manufacturer and fixing with aluminium frame work including providing and fixing with 2 way EPDM gasketing , to ensure water and air tightness and neoprene cushions/ gasket accommadated in grooves, necessary SS-304 screws etc all complete generally as per drawings specifications and as directed by the Engineer-in-charge. Note:- Only clear opening of glass shall be measured for payment. ( 6 mm thick Single Glass Unit (SGU) using heat strengthened (HS) clear float glass of M/s. Saint Gobain ET/ST series or approved equivalent)
Frameless Swing Doors (Patch Fitting Doors): Providing, supply, fabrication, installing, fixing, testing, cleaning, protection and handing over the single leaf / double leaf frameless swing doors (patch fitting door) system made out of 12 mm thick fully tempered (FT) glass with approved make, shape, size stainless steel patch fittings, at all levels, locations, floors as per approved drawings including all labour, material, wastage, transporation, fixing in position, scaffolding etc complete all as per specifications, drawings and as directed by the Engineer-in-Charge. The system shall with stand the wind pressure of confirming to IS -875 part III. Fabrication, supply and installation of frameless Façade using clear, fully tempered glass of specified thickness for fixed glazing and openable panels (doors) with crystal edge polish using glass of approved make and brand fixed in aluminium frame work or without frame work including making necessary holes (wherever required for door fittings & fixtures), providing & fixing heavy quality and approved make necessary patch fittings etc complete all as per specifications, drawings and as directed by the Engineer in Charge. (Note:- Door lock, Floor springs, SS handles, Anodised alumnium frame work will be paid under relevant item. The cost of work is inclusive for any SS patch fittings required for work such top & bottom pivot, fixing arrangement for floor spring)
Frameless openable panels (swing doors) using 12mm thick fully tempered (FT) glass for door leaves including making cut outs/ holes, finishing the edges with crystal edge polish ,sealents etc complete (Note:- Glass area alone shall be measured and paid)
Automatic Sliding Doors: Providing, supply, fabrication, installing, fixing, testing, cleaning, protection and handing over the Automatic sliding doors system consist of 12 mm thick fully tempered (FT) glass, at all levels, locations, floors as per approved drawings including all labour, material, wastage, transporation, fixing in position, scaffolding etc complete all as per specifications, drawings and as directed by the Engineer-in-Charge. The system shall with stand the wind pressure of confirming to IS -875 part III. Fabrication, supply and installation of automatic sliding door using clear, fully tempered glass of specified thickness for fixed glazing and openable panels (doors) with crystal edge polish using glass of approved make and brand including making necessary holes (wherever required for fittings & fixtures), Including providing & fixing microwave cured EPDM gasket, non staining weather sealant, SS-304 grade pan head screws etc complete.
Frameless openable panels (sliding doors) using 12mm thick fully tempered (FT) glass for door leaves including making cut outs/ holes, finishing the edges with crystal edge polish , sealents etc complete (Note:- Glass area alone shall be measured and paid)
Providing & fixing in position Structural steel work using mild steel for frame work as per drawing & design using sections such as pipes, angles, plate, tee, channels etc conforming to IS standards including providing & applying blast cleaned surface, zinc rich epoxy primer (75 micron), epoxy barrier (125 micron) and polyurethene finish (50 micron) for exposed surfaces including providing & fixing approved quality, size, shape SS-304 anchor fastners for fixing the system with RCC members, SS nut bolt for connections, cutting, welding etc complete all as per specifications, drawings & as directed by the Engineer-in-Charge. {The weight of structural steel sections only will be mesured for payment}).
Providing and Fixing of Auto-Sliding door system with All required Hardware's and accessories (Make-Dorma / OZONE / RECORD) or approved equivalent including Providing & fixing motor, roller, all required parts, components & accessories for smooth functioning of automatic sliding door system etc complete all as per drawing, specifications and as directed by the EIC. Fail Safe: The above system is incoporated with Electro magnetic lock - Failsafe. Incase of power failure the operator draws the power from battery back up & remain in opening position. Fail Secure: The above system is incoporated with Electro Mechanical lock - Failsecure. Incase of power failure the operator draws the power from battery back up & close the moving panel.
The system shall be easy in operation and very sturdy design with Self balancing Panel suspension system and with Anti-Jump fitting. The track profile should be separate from the main profile for enabling reduction in vibration insulation, With backplate for easy Installation. Microprocessor-controlled control unit, Self-learning, with adjustable parameters for opening and closing speed, hold-open time and opening and closing force, reversing when obstruction is encountered, with SMPS, Class of protection IP 20. The system is connected with External PLC logic module to create vestibule Airlock system. Activators- dormakaba Vio / IXIO Combination Radars System (04 Nos) on Inside & Outside,Program Switch with Key, C ES 200 Easy, Minimum Panel Weight Carrying Capacity of 2 X 100 Kgs.
Sliding Windows: Providing, supply, fabrication, installing, fixing, testing, cleaning, protection and handing over the Sliding window system, at all levels, locations, floors as per approved drawings including all labour, material, wastage, transporation, fixing in position, scaffolding etc complete all as per specifications, drawings and as directed by the Engineer-in-Charge. The Sliding Window system shall with stand the wind pressure of confirming to IS -875 part III. The sliding window system shall have SS-304 grade mesh Net shutter panel, drainage gutter profile at bottom track, wool pile with film for weather protection and complete sir sealing. The shutter engagement shall be minimum of 15 mm at top and bottom track to ensure stability under deflection of vertical mullions. Including providing & fixing ball bearing rollers smooth movement of shutters, flush type lock with manual opeartion, microwave cured EPDM gasket, non staining weather sealant, SS-304 grade pan head screws etc complete.
Supplying and fixing in position at all floors, levels & locations, aluminium section [extruded] for aluminium sliding windows sliding as per drawing of approved manufactures with extruded sections of Jindal / Indal / Aluminax or other approved eqivalent sections with size and weights as shown in the drawing, for frames and shutters [including wastages if any] conforming to relevant I.S specifications, with all approved shade & colour anodised aluminium fittings and accessories, locking arrangements, 2 / 3 rollers with ball bearings for sliding shutters of approved quality all as shown in the drawing, including providing and fixing aluminium channel beading / glazing clips fixed with necessary matching anodised screws, grouting the gap with thermocole & polysulphide sealant etc. all complete generally as per drawings, specifications etc., all as directed by Engineer in charge, but excluding the cost of glazing, which will be paid separately. (The aluminium system consist of the extruded aluminium sections of alloy 6063 T5/T6 & tolerances confirming to DIN / EN standards from approved make and manufacturer. The aluminium sections shall have approved shade and colour super durable powder coating with minimum 50 micron thickness. The non visible aluminium sections shall have approved chromatizing treatment.
Providing, Supplying, assembling & installing at all levels, locations & floors, hermatically sealed 6-12-6 mm double glazed vision panel units of approved make comprising of an outer heat strengthened float glass 6 mm thick, of approved colour and shade with reflective soft coating on surface # 2 of approved colour and shade, an inner heat strengthned clear float glass 6 mm thick, spacer tube 12mm wide, dessicants, with moisture absorbing compound (silica gel) including primary seal and secondary seal (structural silicone sealant), refelective coating like Metallic Blue glass / Sterling Silver or Green or other approved equivalent shade, T&P, scaffolding and other incidental charges, wastages etc all complete as per approved shop drawings and specifications and as directed by the Engineer-in-Charge. (Note:- Doubled glazed fixed vision panels shall be measured to the overall dimension on external face as fixed on site (Actual size). For payment, only the actual area of glass on face # 1 of the glass panels (excluding the areas of the grooves and weather silicone sealant) provided and fixed in position, shall be measured in sqm.
Providing and fixing following type of approved quality glass panes for aluminium sliding windows, of approved manufacturer and fixing with aluminium frame work including providing and fixing with 2 way EPDM gasketing , to ensure water and air tightness and neoprene cushions/ gasket accommadated in grooves, necessary SS-304 screws etc all complete generally as per drawings specifications and as directed by the Engineer-in-charge. Note:- Only clear opening of glass shall be measured for payment. ( 6 mm thick Single Glass Unit (SGU) using heat strengthened (HS) clear float glass of M/s. Saint Gobain ET/ST series or approved equivalent)
Providing and fixing in position, at all levels & loaction, stainless steel (SS-304) Mosquito Net/ Wire Mesh/ Wire gauze made with 0.5 mm dia wire and 1.4 mm aperture (on both directions) including fixing, cutting, wastage, scaffolding etc. complete all as per specifications and as directed by the Engineer-in-Charge. Note:- 1) For aluminium work with aluminium beading channel. (Aluminium beading channel will paid under relevant item).
Side Hung / Casement Aluminium Windows: Providing, supply, fabrication, installing, fixing, testing, cleaning, protection and handing over the Side Hung / Casement Aluminium window system, at all levels, locations, floors as per approved drawings including all labour, material, wastage, transporation, fixing in position, scaffolding etc complete all as per specifications, drawings and as directed by the Engineer-in-Charge. The Side Hung / Casement Aluminium Window system shall with stand the wind pressure of confirming to IS -875 part III. The Side Hung / Casement window system shall have heavy duty self balancing pivot hinges, three point locking with handle, friction hinges (250 mm) microwave cured EPDM gasket, non staining weather sealant, SS-304 grade pan head screws etc complete.
Supplying and fixing in position at all floors, levels & locations, aluminium section [extruded] for aluminium Side Hung / Casement windows sliding as per drawing of approved manufactures with extruded sections of Jindal / Indal / Aluminax or other approved eqivalent sections with size and weights as shown in the drawing, for frames and shutters [including wastages if any] conforming to relevant I.S specifications, with all approved shade & colour anodised aluminium fittings and accessories, including providing and fixing & grouting the gap with polysulphide sealant etc. all complete generally as per drawings, specifications etc., all as directed by Engineer in charge, but excluding the cost of glazing, which will be paid separately. (The aluminium system consist of the extruded aluminium sections of alloy 6063 T5/T6 & tolerances confirming to DIN / EN standards from approved make and manufacturer. The aluminium sections shall have approved shade and colour super durable powder coating with minimum 50 micron thickness.
Providing and fixing following type of approved quality glass panes for aluminium sliding windows, of approved manufacturer and fixing with aluminium frame work including providing and fixing with 2 way EPDM gasketing , to ensure water and air tightness and neoprene cushions/ gasket accommadated in grooves, necessary SS-304 screws etc all complete generally as per drawings specifications and as directed by the Engineer-in-charge. Note:- Only clear opening of glass shall be measured for payment. ( 6 mm thick Single Glass Unit (SGU) using heat strengthened (HS) clear float glass of M/s. Saint Gobain ET/ST series or approved equivalent)
Total of PART I-G : Doors and windows
PART I-H : Fittings and Fixtures Note:- Fittings & Fixtures i) One sample board consisting of each item of schedule of quantities with approved quality fittings & fixtures & necessary accessories including chromium plated brass screws, bolts, nuts, washers should be submitted for approval of Engineer-in- charge. Large scale procurement shall be taken up only after approval of the Engineer-in-charge. After approval, the samples shall be kept in the office of the Engineer-in-charge to ascertain the approved quality for the entire work. ii) All fittings & fixtures shall conform to relevant IS code.
Providing and fixing aluminium die cast body tubular type universal hydraulic door closer of approved make conforming to IS: 3564 with ISI mark including necessary accessories and screws etc for fixing with alumnium/ wooden/ steel doors with necessary bolts & nuts, labour, scaffolding etc complete all as per specifications and as directed by the Engineer-in-charge.
Providing, fixing & Supplying at site of work approved quality and manufacturer, confirmed & marked with relevant IS (wherever applicable), Stainless steel (SS-304) fittings, fixtures and fastenings along with Stainless steel screws/concealed SS screws, bolts, nuts, washers,wooden packing pieces if necessary etc.and other accessories etc complete all as per specifications and as directed by the Engineer-in-Charge.
SS But hinges (Heavy Weight) of size (100 X 75 X 3.0 mm) , ball bearing type, (Two / Three leaf Hinges)
SS top hung Pivot scissor hinge, heavy quality stainless steel (SS-304 grade) adustable friction window stay (205 X 19 mm)
S. S. Tower bolt 300 mm long x 12 mm barrel
Providing, supplying, fixing approved make back to back stainless steel Handle-450 mm long (Set including a pair of handles), of minimum 25 mm dia, including accessories for fixing it to glass, aluminium, wood shutter, brackets etc.complete as directed by EIC. (Note:- Cost is for one set consists of two nos of handles to fix on shutter both side (Inside & Outside))
S. S. Aldrop 250 mm long x 16 mm diameter rod with an extra staple.
GRAB HANDLE FOR ADA TOILETS: Providing & fixing 25 mm diameter (1.5mm thick) SS 304 satin (brush) finish Grab handle for disabled toilet door of 600mm long of approved make with necessary SS 304 grade screws etc. complete as per drawing as sample approved by Engineer-in-charge.
Providing & Fixing 6- lever Mortice lock of chromium plated SS-304 parts & body of approved brand & make, 200 mm Handle Set Lock Body CK mortice lock with chromium plated SS screws, with duplicate keys etc. lock shall be fitted as per manufacturer specification and as directed by Engineer in charge.
Providing & Fixing 6- lever Mortice lock of chromium plated SS-304 parts & body of approved brand & make, 200 mm Mortice latch & lock (without Handle Set) Lock Body CK mortice lock with chromium plated SS screws, with duplicate keys etc. lock shall be fitted as per manufacturer specification and as directed by Engineer in charge.
Providing and fixing 6 Lever Mortice Lock (Chromium plated SS-304 100 mm mortice latch and lock without pair of handles) of approved make suitable for aluminium sections with necessary screws, material, labour, cutting, making good, duplicat keys etc complete all as per specifications and as directed by the Engineer-in-Charge.
Providing and fixing Mortise shaft dead bolt with key (Alen Key lock) with 57mm backset and 25mm square forend in stainless steel satin finish of approved make including all labour, material etc complete all as per specifications and as directed by the Engineer-in-Charge.
Aluminium Framed Doors Providing, fixing & Supplying at site of work approved quality and manufacturer, confirmed & marked with relevant IS (wherever applicable), Stainless steel (SS-304) fittings, fixtures and fastenings along with Stainless steel screws/concealed SS screws, bolts, nuts, washers,wooden packing pieces if necessary etc.and other accessories etc complete all as per specifications and as directed by the Engineer-in-Charge.
Multipoint cylinder lock, cover with triplicate keys, having size 100 mm long
Concealed tower bolt for aluminium double door shutters (Overall size of 171 mm X 25 mm)
Providing, supplying, fixing glass to glass 6 lever SS patch lock (Round type) of approved make on glass for doors complete as per drawing. Frameless Swing Doors (Patch Fitting Doors) :
Providing and fixing double action hydraulic floor spring of approved brand and manufacture having ISI mark as IS : 6315, having brand logo embossed on the body / plate with double spring mechanism for doors, including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and having minimum 1.25 mm thickness stainless steel cover plates with brass pivot and single piece M.S. sheet outer box with slide plate, and other accessories required for the works to facilitate smooth operation of the door shutter etc complete all as per specifications and as directed by the Engineer-in-charge.
Total of PART I-H : Fittings and Fixtures
PART I-I : Waterproofing treatment Please refr Additional Notes.
Providing and laying water proofing treatment to vertical and horizontal surfaces W.C., Bath & Kitchen and the like consisting of: 1st course of applying cement slurry @ 4.4.Kg/sqm mixed with water proofing compound conforming to IS:2645 in recommended proportions. 2nd course of cement plaster 1:4 (1 cement : 4 coarse sand) using Reday Mix Mortar mixed with water proofing compound in recommended proportions, 20mm thick up to finished floor level and 15mm thick above finished floor level up to 600 mm. 3rd course of applying blown or residual bitumen applied hot at 1.7 Kg per sqm of area. 4th course of 400 micron thick PVC sheet (Overlaps at joints of PVC sheet should be 100 mm wide and pasted to each other with bitumen @1.7 Kg/sqm) etc complete all as per specifications and as directed by Engineer-in-Charge.
Providing cement based waterproofing treatment to the inside surface of water tank by giving injections to concrete bottom slab and walls with cement and approved water proofing compound solution to fill up all inherent holes, voids, honey combs etc in concrete as per 'Injection & Surface' method of the agency approved by the department using cement based waterproofing treatment of 50 mm and 25 mm thick for the floor and walls respectively, of the overhead water tank on terrace / Underground water tank / swimming pool, finished perfectly smooth to correct line, level and plumb including preparing the existing surfaces, necessary scaffolding, finishing smooth, curing etc. complete as per waterproofing agency's specifications and testing water tank for the water tightness and rectification of defects, if any, to render the outer surface bone dry etc complete as per specifications & as directed by the Engineer in charge. (Note:- The measurement for payment shall be actual area covered by treatment.).
Providing and laying integral cement based waterproofing treatment of the agency approved by department, including preparation of surface as required for treatment of roofs, terraces etc mixing with waterproofing compound as per IS:2645, with average thickness of 115mm and minimum thickness at drain point as 65 mm. Following works are included in above item
(i) Applying and grouting a slurry coat of neat cement using 2.75 kg/sqm. of cement admixed with proprietary water proofing compound over the RCC slab including cleaning the surface before treatment. (ii) Laying cement concrete using broken bricks/brick bats 25 mm to 100 mm size with 50% of cement mortar 1:4 (1 cement : 4 coarse sand) using Ready mix mortar admixed with proprietary water proofing compound over 20 mm thick layer of cement mortar of mix 1:4 (1 cement : 4 coarse sand) using Ready mix mortar admixed with proprietary water proofing compound to required slope and treating similarly the adjoining walls up to 300 mm height including rounding of junctions of walls and slabs. (iii) After two days of proper curing applying a second coat of cement slurry admixed with proprietary waterproofing compound. (iv) Finishing the surfaces with 20 mm thick jointless cement mortar of mix 1:4 (1 cement : 4 coarse sand) using Ready mix mortar admixed with proprietary water proofing compound and finally finishing the surface to receive the China Mosaic waterproofing treatment. (v) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by the Engineer in Charge.
Extra for additional thickness of brick bat coba over and above standard average thickness of 115 mm for effective slope wherever required etc complete all as per specifications and as directed by Engineer-in-Charge.
Providing China Mosaic water proofing over concrete / plastered surface of horizontal, vertical, sloped/ curved surfaces, rounded vatas, sharp corners, junctions etc., using broken pieces of approved colour/assorted ceramic tile laid over and including 20mm thick cement mortar 1:4 using Reday mix mortar screed mixed with approved waterproofing compound @ 2% by weight of cement, cost of all materials, labour, curing, breaking the tiles to the pieces of required size and shape, laying / fixing the tile pieces to the required line, slope, levels etc., providing extra screed as required for quick & easy flow of water, curing etc., at all height sincluding necessary scaffolding, cleaning the surface initially with saw dust and finally with acid all as per specifications and as directed by the Engineer-in-Charge.
Supplying, applying and placing swellable type water stop tape of size 19 mm x 25 mm thick of expansive nature for construction joints treatment of RCC structures such as raft slab, retaining walls, walls of water tank & at junction of raft slab with the reatianing wall including cleaning the construction joints of loose mortar and dust, applying primer @ as per manufacturer specification, unroll the water bar slowly and carefully on the joint without pulling and stretching it too much after the primer dries a little and became sticky and tying with the reinforcement bars as directed all complete as per manufacturer's specification and as directed by Engineer-in-Charge.
Providing and laying at all levels, floors & loaction an elastic (300%), pasty, solvent-free and UV resistant synthetic Waterproofing system with excellent bonding to the substrate manufatured by approved manufacturer, the waterproofing system is brush applied in two coats, reinforced with Glass Fiber Mesh between each coat, which forms a highly flexible, water-tight and water permeable coating. including treating the joints such as construction joint and separation joint with High Strength Polymer Modified Mortar, cleaning etc to ensure an un-interrupted and even coating of waterproofing application, testing the water tightness by ponding water for 7 days etc complete all as per specifications and as directed by the Engineer-In-Charge. Note: No extra payment shall be made for arrangement of water for carrying out necessary water tightness test.
Total of PART I-I : Waterproofing treatment
PART I-J : Plastering work Notes:- a) Before commencement of plastering, the area shall be cleaned, wetted and shall be marked with Thiyyas' or 'Tapanis' and shall be got approved by the Engineer-in-charge. b) Whenever the electrical contractor/agency has to fix up switch boxes in walls, necessary Thiyyas or 'Dhadas' shall be arranged prior to plastering so that the electrical boxes are fixed properly in line with the finished plastered surfaces. c) Finishing around the junction boxes shall be done at all floor, level and position to the line, level and right angles as required while carrying out plastering work. d) No extra claim/cement consumption shall be entertained by the department for the plastering done more than the specified thickness shown in the schedule of quantities, to bring the plastered surface to perfect line, level and plumb with adjoining columns and beams.
Cement plastering work using ready mixed cement sand mortar and finished thickness as specified below at all floors, levels & locations, in single/ double coat (as specified) over concrete/ masonry surface including surfaces preparation, even & smooth surface in correct line, level, plane, plumb and including scaffolding, curing etc complete all as per specifications and as directed by EIC.
6 mm thick cement plaster in single coat Using ready mix cement mortar having Cement : Sand (1:4) for exposed concrete surfaces, soffit of slabs, soffit of beams, stair case waist slab etc.
15 mm thick cement plaster in single coat Using ready mix cement mortar having Cement : Sand (1:4) for internal masonry work, concrete surfaces for walls, beams flush with walls, mullinons etc.
Sand faced plastering work cement sand mortar (1:4) using ready mix cement mortar having cement : sand (1:4) and finished thickness as specified below at all floors, levels & locations, in single/ double coat (as specified) over concrete/ masonry surface including surfaces preparation in correct line, level, plane, plumb and including scaffolding, curing etc complete all as per specifications and as directed by EIC. (20 mm thick in two coats for brick/ concrete surfaces (external / internal) (back coat and finishing coat of 10 mm. thick each) with water proofing agent @ 2% by weight of cement or as per manufacturers specifications.
Providing & fixing in position GI chicken wire mesh / plaster mesh (Hexagonal shape) of 12 mm size hole, made out of galvanised wire of nominal thickness 22 Gauge with zinc coating with necessary "U" hooks, clips or nails at all floors, levels & locations, wherever required to prevent development of cracks in plaster surfaces (Wall-beams joint, Wall-column joint, electrical chasing work, opening of door window to prevent diagonal cracks and other similar loactions to prevent development of cracks in plaster surface) including cutting, fixing, wastage etc complete all as per specifications, drawings and as directed by the Engineer in charge (Only area of chicken mesh provided shall be measured for payment)
Providing vatas 150 x 150 mm at junction of walls and chajjas canopies etc. with cement mortar 1:4 using Ready Mix Mortar (RMM) of approved maufacturer to match surrounding plaster to the required profile including adding water proofing compound @2% by weight of cement or as per manufacturers specification, scaffolding‚ curing etc. complete as per specifications and drawings and as directed by the Engineer-in-charge.
Sand faced plastering work cement sand mortar (1:4) using ready mix cement mortar having cement : sand (1:4) and finished thickness as specified below at all floors, levels & locations, in single/ double coat (as specified) over concrete/ masonry surface including surfaces preparation in correct line, level, plane, plumb and including scaffolding, curing etc complete all as per specifications and as directed by EIC. (12 mm thick in single coat for independent concrete surfaces with water proofing agent @ 2% by weight of cement or as per manufacturers specifications.
Total of PART I-J : Plastering work
PART I-K : Painting work
Providing and applying 1.5 mm thick white cement based wall care putty in two coats of approved make, at all floors, levels and locations, over plastered surfaces finished smooth to correct line, level, plane, plumb etc., including preparing the surfaces, scaffolding smoothen the putty surfaces with very fine water proof emery paper to get a glossy finish etc. complete as per specifications, as per manufacturers specifications, drawing & as directed by the Engineer-in-charge.
Providing & applying acrylic emulsion (plastic) paint for internal plastered surfaces in two or more coats on new surfaces at all floors, levels & location using ready mixed & ready made acrylic emulsion paint of approved make and shade including one coat of approved cement / acrylic primer (water thinnable) including labour, material, scaffolding, surface preparation, cleaning etc complete all as per specifications and as directed by Engineer-in-Charge. (Note:- Acrylic emulsion shall have VOC content less than 50 grams/ litre)
Providing & applying 100% premium acrylic emulsion (plastic) paint having Alkali & fungal resistance, dirt resistance, for internal plastered surfaces in two or more coats on new surfaces at all floors, levels & location using ready mixed & ready made acrylic emulsion paint of approved make and shade including one coat of approved cement / acrylic primer (water thinnable) including labour, material, scaffolding, surface preparation, cleaning etc complete all as per specifications and as directed by Engineer-in-Charge. (Note:- Premium Acrylic emulsion shall have VOC content less than 50 grams/ litre)
Providing & applying exterior grade 100% acrylic emulsion paint for external surfaces (plastered / concrete) in two or more coats on new surfaces at all floors, levels & location using ready mixed & ready made acrylic emulsion paint of approved make, shade and pattern including one coat of approved acrylic based water repellent primer including labour, material, scaffolding, surface preparation, cleaning etc complete all as per specifications and as directed by Engineer-in-Charge. (Note:- Acrylic emulsion shall have VOC content less than 50 grams/ litre. UV resistance as per IS:15489, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives.
Total of PART I-K : Painting work
PART I-L : Miscellaneous work Please refer Additional Notes.
Structural steel work at all floors, levels and locations in grills, guard bars for windows, frames, Fence, pit/ trench covers, cover bracket for slanting chajja, trap door, railing, balcony hand railing, hoisting hooks, smoke vents etc. using angles, channels, I-Section, tees, flats, bars, chequered plates, plain plates, hollow section, bright bars etc. of required sizes including supplying, cutting, fabricating, welding, erecting, making holes/ chases wherever required and fixing / embedding in position in concrete/ brickwork/blockwork/ marble/ granite stone with necessary hold fasts/ stainless steel screws & rawl plugs by drilling etc. and finishing the concrete/ brick work/ blockwork after fixing/ embedding including painting two coats of anti corrosive bitumastic paint on all unexposed surfaces and two coats of synthetic enamel paint of approved make and colour on all exposed surfaces over a coat of approved zinc chromate primer and including cost of required scaffolding, propping, stagging etc. complete as per specifications, drawings and as directed by the Engineer in charge. Note:- All structural steel work shall be as per latest version IS:800 & IS:806. All Rectangular and Square Hollow Sections (RHS & SHS) shall be conforming to latest version of IS:4923. All rolled sections shall be of Grade E-250 and conforming to latest verison of IS:2062. Welding shall be as per IS:816 & IS:6227.
Using structural steel sections of specified grade (Yst 240)
Using structural steel sections of specified grade (Yst 310)
Using structural steel sections of specified grade (Yst 350)
Providing & fixing, at all levels, floors & location, Deck Sheet TR60+, minimum 0.9 mm thick, 275 GSM, 355 Mpa, Accessories & Shear Studs : Providing and fixing of M/s. JSW or approved equivalent SMD TR60+, 0.9 mm, S355 composite floor decking of profile depth 60mm and cover width 666mm, manufactured from Hot Dip galvanized structural quality of grade S355 (minimum yield strength of 355 MPa ) steel coil to BS EN 10143 & BS EN 10346 of specified thickness and with a minimum galvanized coating mass of 275g/m2. The decking is profiled with indentations to achieve adequate bonding with concrete to act as a composite deck. The decking profile is designed to support wet concrete loads, superimposed live loads, dead loads (including self-weight of slab), with minimum 2 hr fire rating. The deck sheet shall be fixed to support with self tapping screws of Hilti S-MD05Z (5.5mm x 38 mm) or approved equivalent as per manufacturer’s recommendation
and including providing and fixing of Edge Trims, Flashings, end caps and restraint straps to form slab edges to perimeter and service voids, shear studs of 19mm diameter x 95mm length after weld (LAW) of material type SD with minimum yield strength of 355MPa and ultimate tensile strength of 450MPa in accordance with BS EN ISO 13918, including providing & fixing 3 mm dia wire mesh having 100 mm X 100 mm grid, scaffolding, staging etc complete all as per specifications, drawings and directed by the Engineer-in-Charge.
Providing and fixing Duraboard HD 100 filler board of M/s. Supreme Industries Ltd. of specified thickness and width as shown in the drawing, for expansion joint at all floors and locations in RCC columns,beams , slab, brackets etc. including cutting, laying in position in line, level and plumb etc. as per manufacturers specifications including cost of all materials, labour, scaffolding etc. complete all as per specifications, drawings and as directed by the Engineer- in- Charge. (100 mm thickness)
Providing and laying of light weight material fill of RIGID CELLULAR STYROFILL Geofoam Blocks conforming to IS: 4671, manufactured by approved manufacture, on structural slab at all floors, levels & locations, the Styrofill blocks having higher compressive strength, low water absorption, good flexural strength, durability and including surface preparation, cutting the styrofill blocks to required dimensions at site, fixing of styrofill blocks to required line & level using rubberised cold bitumen adhesive (RBA compound) all as per specification, drawing and as directed by the Engineer In Charge. (Styrofill Foam Blocks with load bearing capacity 2.5 Tons/M2 - Medium duty (flexural strength of minimum 172 kPa. Water absorption max 2%)
Providing copper metal cradle of suitable width [approximate 600mm] for expansion joint at floor level bent to shape, cutting, screwing, over lapping etc., filled up with Bitumen filler including placing 20 mm thick Kotah stone/18mm granite stone laid over a coat of Hot Bitumen for entire length along the joint, to match the floor finish, fixing aluminium flats/ angles/ sheets (to be paid under relevant items) at bottom to cover the joint, cut to required size and shape etc. including cutting, positioning, supporting, wastages, filling with approved polysulphide, sealing compound, chipping the old concrete surface etc., including all tools and plants at all levels & location all as specification and as directed by the Engineer in charge. Note:- a) Granite/Kotah stone is to be measured under relevant items.
Providing & fixing in position anodised (Transparent or dyed to required shade, Minimum anodic coating of 15 micron) Aluminium flats / angles/ tees / plates (200mm wide & 5mm thick sheets) / foils etc of required size & pattern to cover the expansion joint in walls, floors, ceilings and columns etc including drilling holes, chasing the surface wherever required, fixing with wooden gutties, rawl plugs and C.P. brass screws, making oval shaped slot in aluminium on one side, fixing stainless steel washers, making good the concrete/ Brick surface, scaffolding etc, complete as per drawing, specification and as directed by the Engineer in charge.
Providing and applying single component low VOC water based acrylic Instumescent coating of M/s. SUNNOFLAME IP or approved equivalent make, the total DFT of system shall be minimum 4 mm thick having fire rating of 2 hrs and applying using heavy duty airless spray equipment (recommended) at a coverage of 1 sqm/kg/coat for a wet film thickness not more than 700 micorns per coat, at all floors, levels, location including all wastage, labour, material, scaffolding etc complete all as per specifications and as directed by the Engineer-in-Charge. (For Vertical member)
Providing and Applying Low Density Vermiculite Spray of M/s. Newkem Isolatek or approved equivalent make, Fire Proof Coating of Structural Steel comprising of single pack factory blended & ready-mix fireproof coating consisting of exfoliated vermiculite with cement / gypsum and special additives and fillers but excluding glass fibers or organic aggregates and designed to adhere firmly to structural elements from cellulosic fire and tested to BS 477 Pt 20/21 - UL 273 for the required fire rating of (2 Hrs) for the structural steelwork, at all floors, levels, location including all wastage, labour, material, scaffolding etc complete all as per specifications and as directed by the Engineer-in-Charge. (For Horizontal members)
Providing and Applying single coat of topcoat with aliphatic acrylic polyurethane coating having very good gloss retention, and DFT of 50 microns to be achieved in one coat, at all floors, levels, location including all wastage, labour, material, scaffolding etc complete all as per specifications and as directed by the Engineer-in-Charge. (For vertical members)
Supplying and Grouting of Conbextra GP2 (FOSROC or approved equivalent) free flow, high strength, Non shrink, cementitious precision grout below base plates of columns, trusses, equipment, around foundation bolts, gap between pedestal top of columns and base plate etc. grouting should be carried out with grouting gun including cleaning by water/ compressed air or suitable grouting compound / chemical as per the manufacture's specifications including making the pockets for concrete foundations, pedestals etc, as per the requirement, necessary formwork, cost of labour, materials, scaffolding, transportation, tools & plants, loading and unloading charges, devices for grouting, finishing, all other incidental charges, etc. complete with lead & lifts at all levels etc complete all as per specifications and as directed by Engineer-in-charge
Providing and fixing PUF Insulated continueous sandwich panels for roofs of total thickness not less than 30 mm made out from continue line method, Panel shall have 0.5 mm thick pre coated GI sheet on both side of Polyurethane foam with external face being corrugated in shape for GI and PU foam both material, The crest height of the panel shall be of 35mm minimum wiht 250mm c/c pitch, The Precoated sheet shall be of minimum 240 mpa steel grade confirming to IS 14246:1995 and shall have zinc coating of 120 gsm as per IS:277 , 5 microns epoxy primer on both side of the sheet and polyester top coat 15 micron, the GI Sheet shall have protective guard film of minimum 25 microns to avoid scratches wihile trasportation and including fixing over a frame work of trusses, columns and purlins fixed using 90mm self drilling bolt with rubber washer including all types of flashings, PU Foam must be self-extinguishing, fire retardant type having minimum density of 40 Kg/Cu.mt.( +, - 2 Kgs) including 0.25mm craft paper edging, including scaffolding etc complete all as specifications and as directed by EIC.
Back Painted Glass:Providing and fixing of minimum 6 mm thick annealed premium lacquered glass manufactured by curtain coating process with PU lacquer (50 micron thick), opaque (if viewed against a support wall) conforming to standards for back painted glass, of approved colour & shade, highly durable (passes PERSOZ hardness test for minimum 220 oscillations); humid resistant (conforms to BS EN 1036 1999); environmentally friendly (no lead, no arsenic, no copper, no formaldehyde); appropriate recycled content (12% post industrial / 6% post consumer); compressive strength (1000 MPa) and tensile strength (40 MPa),same as float glass and including P&F epoxy based silicone for glass fixing having Shear Bond Strength (Dry, 24 hours), greater than 450 kpa and tack free time of 10 to 30 mins compatible for installation of mirror and lacquered glass / Mirror mounting tape - Foam based double sided adhesive tape for instantaneous adhesion, compatible with mirror and lacquered glass having Shear bond strength
(Dry, 15 mins) of 250 to 350 kpa on a perfectly leveled 12mm thick water proof marine plywood / MDF / Mineral fiber board which is mounted on the RCC wall/any other structure, including submitting test reports for back painted glass from manufacturer - High humidity Resistance (conforms to BS EN 1036 1999); Color fastness ISO 105B02 standard and Mechanical Resistance ISO 7784 ( Taber Abrasion test ) ISO 2409 ( Cross Hatch Test ) standard, environmentally friendly (no lead, no arsenic, no copper, no formaldehyde); appropriate recycled content (12% post industrial / 6% post consumer); compressive strength (1000 MPa) and tensile strength (40 MPa) etc complete all as per specifications and as directed by the EIC.
Providing and fixing in position, Gear Type operated by mechnically winding handle, Steel Rolling Shutters of approved make, made from M.S.laths 18 G, 3" (75 mm) size interlocked together throughout entire length and jointed together at the end by end locks mounted on specially desogned pipes shaft with brackets as per IS standards including all necessary fixtures andfittings, top hood (0.90 mm thick), brackets, guide channels, side guides, ceiling strips, inside & outside locking arrangement and painting with a coat of approved steel primer and two coats of approved make and shade synthetic enamel paint, fixing in position in masonry/concrete with necessary coach screws, nuts, bolts etc. making good the masonry/concrete complete all as per specifications and as directed by the Engineer-in-Charge. (Note:- The measurement for Rolling shutters will be as per structural openings. Hood etc will not be measured separately.)
Providing and fixing at all levels, locations and at all floors, 50 mm thick Reinforced precast Jali in C.C 1:2:4 of approved pattern, design and shape including pointing and proper joining of junctions with ready mix cement mortar including all formwork, reinforcement, finishing the surface, curing, scaffolding, hoisting, erecting & fixing in position etc complete all as per specifications and as directed by EIC.
Supplying and fixing in position various dia GI pipe for sleeves, using 'B' class (medium duty) GI pipes of any diameter as per requirement and as per drawing for sleeves etc. including cutting, placing in position, bending, welding, in line and level, at all levels & location including painting with one coat of approved zinc chromate primer, scaffolding. labour, wastage etc. complete all as per specifications, drawings and as directed by the Engineer in charge
Total of PART I-L : Miscellaneous work
PART I-M : Facade work Please refer Additional Notes
Conventional Cap Curtain wall system: Providing, supply, fabrication, installing, fixing, testing, cleaning, protection and handing over the conventional cap curatin wall system, at all levels, locations, floors as per approved drawings including all labour, material, wastage, transporation, fixing in position, scaffolding etc complete all as per specifications, drawings and as directed by the Engineer-in-Charge. The Conventional capped curtainwall system shall with stand the wind pressure of confirming to IS -875 part III. The profile system is based on capped curtainwall design and glass is held all around by mechanical pressure plate and cap with microwave cured EPDM gaskets in all four sides of glazing, with necessary brackets MS with HDG with three dimensional adjustment with serrations and serrated washers to arrest the wind load movement, anchor Fasteners, screws and fasteners with Non-staining weather sealant and Aluminium flashing all around parameter inside and outside to seal the gaps between curtain wall and the building structure etc
all complete requirement to perform as per specification and drawing in conjunction with item description. The system shall include pressure equalization with minimum 2 barrier gaskets for improved weather performance, drainage at all floor levels, to accommodate building movements, thermal expansions & the seismic movements. The system shall be perform considering surface temperatures of 80-90 deg Cel & temperature differential of 25 deg cel without creating excess stress in the system.
All metal joints in the wet area shall be small joint sealant applied to ensure water tightness. The system shall be installed spanning between the floors with brackets with provision to accommodate movement at all floor levels and at every grid panels horizontally. The system shall be installed to accommodate vision panel area . The system shall be including providing & fixing openable panel as per drawing of system. All fix vision glass and openable shall look similar in the elevation. Aluminium Edge Guard with Black Anodized shall be fixed at all vertical & Horizontal grooves. Each glass panel shall be supported for dead load at the bottom of glass with black anodised glass retainers two per panel. Including Providing & fixing Flasing / Trim / Floor Closure at Parapet level, floor level, beam bottom level and required flashings shall be provided continueously with required GI / Aluminium sheet (as per darwing). Internal & External concealed Flashings shall be 1.0 mm thk GI sheet. External exposed flashing shall be 1.5mm thk. Aluminium sheet with SDF coated matching with external Aluminium profiles. Internal exposed flashing shall be 2mm thk. Aluminium sheet with powder coated matching with internal aluminium profiles.
The aluminium system consist of the extruded aluminium sections of alloy 6063 T5/T6 & tolerances confirming to DIN / EN standards from M/s. Jindal/Hindalco or approved equivalent make and manufacturer. The aluminium sections shall have approved shade and colour super durable powder coating with minimum 50 micron thickness. The non visible aluminium sections shall have approved chromatizing treatment. Including providing & fixing approved make EPDM Gasket ( Micro cured (online curing) with shore A hradness of 60-65), approved make non staining weather & structural sealant, SS-304 pan head screws, nut bolts, washers, SS-304 grade anchor fastners (M/s. Hilti or approved equivalent) etc complete. ( The weight of extruded aluminium sections only will be mesured for payment).
Providing and fixing following type of approved quality glass panes of approved manufacturer and fixing with aluminium work and providing and fixing with EPDM gasketing, to ensure water and air tightness and neoprene cushions/ gasket accommadated in grooves, necessary bronze anodised screws etc, all complete generally as per drawings specifications and as directed by the Engineer-in-charge. Note:- Only clear opening of glass shall be measured for payment. (10 mm thick Single Glass Unit (SGU) using heat strengthened (HS) clear float glass of M/s. Saint Gobain ET/ST series or approved equivalent)
Providing, Supplying, assembling & installing at all levels, locations & floors, hermatically sealed 6-12-6 mm double glazed vision panel units of approved make comprising of an outer heat strengthened float glass 6 mm thick, of approved colour and shade with reflective soft coating on surface # 2 of approved colour and shade, an inner heat strengthned clear float glass 6 mm thick, spacer tube 12mm wide, dessicants, with moisture absorbing compound (silica gel) including primary seal and secondary seal (structural silicone sealant), refelective coating like Metallic Blue glass / Sterling Silver or Green or other approved equivalent shade, T&P, scaffolding and other incidental charges, wastages etc all complete as per approved shop drawings and specifications and as directed by the Engineer-in-Charge. (Note:- Doubled glazed fixed vision panels shall be measured to the overall dimension on external face as fixed on site (Actual size). For payment, only the actual area of glass on face # 1 of the glass panels (excluding the areas of the grooves and weather silicone sealant) provided and fixed in position, shall be measured in sqm.
Extra for openable side hung, top hung, doors, windows, ventilators shutter vision glass panels (IGUs) including providing and supplying at site all accessories and hardwares for the openable panels as specified and of the approved make such as heavy duty stainless steel friction hinges, min 4- point cremone locking sets with stainless steel plates, handles, buffers etc. including necessary stainless steel screws/ fasteners, nuts, bolts, washers etc.all complete as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer- in-Charge.
Providing and fixing frosted strip glass film (Vinyl Sheets Sticker) 25 micron thick of approved shade/design of approved make & manufacturer (M/s. Garware / Lukzer or approved equivalent) over glass doors / windows etc including cutting to size, solution for fixing, cleaning the glass, wastage, labour etc. all complete as per specifications and as directed by Engineer in Charge.
Providing & fixing in position Structural steel work using mild steel for Conventional Cap Curtain wall system as per drawing & design using sections such as pipes, angles, plate, tee, channels etc conforming to IS standards including providing & applying blast cleaned surface, zinc rich epoxy primer (75 micron), epoxy barrier (125 micron) and polyurethene finish (50 micron) for exposed surfaces including providing & fixing approved quality, size, shape SS-304 anchor fastners for fixing the system with RCC members (M-10, 110 mm long), SS nut bolt (M-6) for connections, cutting, welding etc complete all as per specifications, drawings & as directed by the Engineer-in-Charge. {The weight of structural steel sections only will be mesured for payment}).
Extra Over for providing and fixing the spandrel panel with the Glass wool insulation of 50mm thick 48 kg/m3 density slab with inbuilt black veil of 0.65mm firmly held on the GI tray Backing of 1.2 mm thk. all assembly is kept at least Min. 50mm away from the glass surface etc complete all as per drawings & specifications
Extra over for providing and fixing the fire stop (smoke seal) for 2 hr Fire rating with smoke seal & Acoustic Seals at all floor slab levels & office to office wall required as per local fire authority with Tested to EN 1364-4 Stnd. 120mm thk. and 25dB(RW) density of Siderise CW-FS & Siderise-AB slab with required GI flashings to hold the assembly shall be fixed in 25% compressed form between the gap of Building RCC and Curtain wall system. The floor closure shall be provided continuously at floor top level with 1mm thk. GI flashing closing gap between curtain wall and building line.
Providing and fixing of 4 mm thick Aluminium Composite Panel (ACP) cladding of approved make and shade at all levels, location & floors including soffits of over-hangs but excluding aluminium frame work with grids filled in with weather silicon sealant as per the drawings for linear as well as curvilinear portions of the building. The Aluminium Composite panel (ACP) composition shall be of 0.5 mm thick PVDF coated aluminium sheet + 3 mm thick low density polyethelene virgin resin core + 0.5 mm thick polyester (PVDF) coated Aluminium sheet, including all labour, material, stainless steel screws, nuts, bolts, washers, cleats, weather silicone sealant, backer rods, cutting, fixing, wastage, scaffolding all complete as per approveddrawings, specifications and as directed by the Engineer-In-Charge. (Note:- Aluminium frame work will be paid under relevant item. ACP shall be measured to the actual visible area of the ACP sheet including silicon joints as fixed on site.).
Dry Stone Cladding (Hard Stone): Providing, supply, fabrication, installing, fixing, testing, cleaning, protection and handing over the Dry stone cladding (Hard Stone) ventilated facade, at all levels, locations, floors as per approved drawings including all labour, material, wastage, transporation, fixing in position, scaffolding etc complete all as per specifications, drawings and as directed by the Engineer-in-Charge. The stone cladding system shall have minimum 30 mm thick Dholpur stone of approved colour & shade to with stand the wind pressure of confirming to IS -875 part III.
Providing & fixing Dholpur stone dry cladding using minimum 30 mm thick Dholpur stone of approved uniform colour, shade, size & source including groove cutting/drilling in stone to fix under cut anchors, chamfering, edge polishing, cutting, wastage, installing under cut anchors with impact free setting tools to avaoid damages to stones & anchors, fixing in position as per drawing in proper line & level including providing & filling non staining weather sealant etc complete all as per specifications, drawings & as ditected by the Engineer-in-Charge.
Supplying and fixing in position at all floors, levels & locations, aluminium section [extruded] for dry stone cladding system as per drawing of approved manufactures with extruded sections of Jindal / Indal / Aluminax or other approved eqivalent sections with size and weights as shown in the drawing [including wastages if any] conforming to relevant I.S specifications, including grouting the gap with polysulphide sealant, etc. all complete generally as per drawings, specifications etc., all as directed by Engineer in charge. (The aluminium system consist of the extruded aluminium sections of alloy 6063 T5/T6 & tolerances confirming to DIN / EN standards from approved make and manufacturer. The aluminium sections shall have approved shade and colour super durable powder coating with minimum 50 micron thickness. The non visible aluminium sections shall have approved chromatizing treatment. {The weight of extruded aluminium sections only will be mesured for payment}).
Providing & fixing in position Structural steel work using mild steel for dry stone cladding system as per drawing & design using sections such as pipes, angles, plate, tee, channels etc conforming to IS standards including providing & applying blast cleaned surface, zinc rich epoxy primer (75 micron), epoxy barrier (125 micron) and polyurethene finish (50 micron) for exposed surfaces including providing & fixing approved quality, size, shape SS-304 anchor fastners for fixing the system with RCC members (M-10, 110 mm long), SS nut bolt (M-6) for connections, cutting, welding etc complete all as per specifications, drawings & as directed by the Engineer-in-Charge. {The weight of structural steel sections only will be mesured for payment}).
Dry Stone Cladding (Hard Stone Perforated Claddding): Providing, supply, fabrication, installing, fixing, testing, cleaning, protection and handing over the Dry stone cladding (Hard Stone Perforated Cladding), at all levels, locations, floors as per approved drawings including all labour, material, wastage, transporation, fixing in position, scaffolding etc complete all as per specifications, drawings and as directed by the Engineer-in-Charge. The dry stone perforated cladding system shall have minimum 30 mm thick Dholpur stone of approved colour & shade to with stand the wind pressure of confirming to IS -875 part III.
Providing & fixing Dholpur stone dry cladding (Perforated Cladding) using minimum 30 mm thick Dholpur stone of (Size 1200 X 300 mm size) having approved uniform colour, shade, size & source including groove cutting/drilling in stone to fix under cut anchors M8x37L, Every single stone panel is fixed In-out 20mm from facade outer surface in a staggered manner with supporting aluminum grid work as per details & drawings, chamfering, edge polishing, cutting, wastage, installing under cut anchors with impact free setting tools to avaoid damages to stones & anchors, fixing in position as per drawing in proper line & level including providing & filling non staining weather sealant etc complete all as per specifications, drawings & as ditected by the Engineer-in-Charge.
Supplying and fixing in position at all floors, levels & locations, aluminium section [extruded] for dry stone cladding system as per drawing of approved manufactures with extruded sections of Jindal / Indal / Aluminax or other approved eqivalent sections with size and weights as shown in the drawing [including wastages if any] conforming to relevant I.S specifications, including grouting the gap with polysulphide sealant, etc. all complete generally as per drawings, specifications etc., all as directed by Engineer in charge. (The aluminium system consist of the extruded aluminium sections of alloy 6063 T5/T6 & tolerances confirming to DIN / EN standards from approved make and manufacturer. The aluminium sections shall have approved shade and colour super durable powder coating with minimum 50 micron thickness. The non visible aluminium sections shall have approved chromatizing treatment. {The weight of extruded aluminium sections only will be mesured for payment}).
Providing & fixing in position Structural steel work using mild steel for dry stone cladding system as per drawing & design using sections such as pipes, angles, plate, tee, channels etc conforming to IS standards including providing & applying blast cleaned surface, zinc rich epoxy primer (75 micron), epoxy barrier (125 micron) and polyurethene finish (50 micron) for exposed surfaces including providing & fixing approved quality, size, shape SS-304 anchor fastners for fixing the system with RCC members (M-10, 110 mm long), SS nut bolt (M-6) for connections, cutting, welding etc complete all as per specifications, drawings & as directed by the Engineer-in-Charge. {The weight of structural steel sections only will be mesured for payment}).
Providing & fixing Rock Wool Insulation having Density 50 kg/cum, having 100 mm thickness and supported on G.I. tray of 1.2 mm thick etc complete all as per specifications and as directed by EIC.
Aluminium Louvers (Box Type Louvers) System: Providing, supply, fabrication, installing, fixing, testing, cleaning, protection and handing over the Aluminium box type louvers system, at all levels, locations, floors as per approved drawings including all labour, material, wastage, transporation, fixing in position, scaffolding etc complete all as per specifications, drawings and as directed by the Engineer-in-Charge. The Aluminium box type louver system shall with stand the wind pressure of confirming to IS -875 part III. The Aluminium box type louver system shall have louvers of size 150 mm X 75 mm X 2 mm thickness vertical box louvers at 175 mm c/c. Including providing & fixing Aluminium frame to support aluminium louvers, Louver profile shall be fixed at an angle (as per drawing) to form a frame, necessary MS brackets with SS-316 fastners, EPDM gasket, non staining weather sealant, SS-304 grade pan head screws etc complete.
Supplying and fixing in position at all floors, levels & locations, aluminium section [extruded] for aluminium box type louver system as per drawing of approved manufactures with extruded sections of Jindal / Indal / Aluminax or other approved eqivalent sections with size and weights as shown in the drawing [including wastages if any] conforming to relevant I.S specifications, including grouting the gap with thermocole & polysulphide sealant, providing & fixing MS brackets etc. all complete generally as per drawings, specifications etc., all as directed by Engineer in charge. (The aluminium system consist of the extruded aluminium sections of alloy 6063 T5/T6 & tolerances confirming to DIN / EN standards from approved make and manufacturer. The aluminium sections shall have approved shade and colour super durable powder coating with minimum 50 micron thickness. The non visible aluminium sections shall have approved chromatizing treatment. {The weight of extruded aluminium sections only will be mesured for payment}).
Aluminium (Y-Type) Louvers System: Providing, supply, fabrication, installing, fixing, testing, cleaning, protection and handing over the Aluminium (Y-Type) louvers system, at all levels, locations, floors as per approved drawings including all labour, material, wastage, transporation, fixing in position, scaffolding etc complete all as per specifications, drawings and as directed by the Engineer-in-Charge. The Aluminium box type louver system shall with stand the wind pressure of confirming to IS -875 part III. The Aluminium Y type louver system shall have louvers of size 60 mm X 36 mm X 1.5 mm thickness of Y shape louvers, fixed at fixed distance (as per drwing) to alumnium frame, louver profile to be fixed on 3 mm thick aluminium flat to form a frame, the louver frame is supported on the aluminium box frame including providing & fixing SS-316 fastners, necessary MS brackets with SS-316 fastners, EPDM gasket, non staining weather sealant, SS-304 grade pan head screws etc complete.
Supplying and fixing in position at all floors, levels & locations, aluminium section [extruded] for aluminium Y type louver system as per drawing of approved manufactures with extruded sections of Jindal / Indal / Aluminax or other approved eqivalent sections with size and weights as shown in the drawing [including wastages if any] conforming to relevant I.S specifications, including grouting the gap with thermocole & polysulphide sealant, providing & fixing MS brackets etc. all complete generally as per drawings, specifications etc., all as directed by Engineer in charge. (The aluminium system consist of the extruded aluminium sections of alloy 6063 T5/T6 & tolerances confirming to DIN / EN standards from approved make and manufacturer. The aluminium sections shall have approved shade and colour super durable powder coating with minimum 50 micron thickness. The non visible aluminium sections shall have approved chromatizing treatment. {The weight of extruded aluminium sections only will be mesured for payment}).
Providing and fixing in position, at all levels & loaction, stainless steel (SS-304) Mosquito Net/ Wire Mesh/ Wire gauze made with 0.5 mm dia wire and 1.4 mm aperture (on both directions) including fixing, cutting, wastage, scaffolding etc. complete all as per specifications and as directed by the Engineer-in-Charge. Note:- 1) For aluminium work with aluminium beading channel. (Aluminium beading channel will paid under relevant item).
Supplying and fixing in position at all floors, levels & locations, aluminium section [extruded] for aluminium manual operable type louver system as per drawing of approved manufactures with extruded sections of Jindal / Indal / Aluminax or other approved eqivalent sections with size and weights as shown in the drawing [including wastages if any] conforming to relevant I.S specifications, including grouting the gap with thermocole & polysulphide sealant, providing & fixing MS brackets etc. all complete generally as per drawings, specifications etc., all as directed by Engineer in charge. (The aluminium system consist of the extruded aluminium sections of alloy 6063 T5/T6 & tolerances confirming to DIN / EN standards from approved make and manufacturer. The aluminium sections shall have approved shade and colour super durable powder coating with minimum 50 micron thickness. The non visible aluminium sections shall have approved chromatizing treatment. {The weight of extruded aluminium sections only will be mesured for payment}).
Skylight with laminated Glass: Providing, supply, fabrication, installing, fixing, testing, cleaning, protection and handing over the Skylight System, at all levels, locations, floors as per approved drawings including all labour, material, wastage, transporation, fixing in position, scaffolding etc complete all as per specifications, drawings and as directed by the Engineer-in-Charge. The Skylight system shall with stand the wind pressure of confirming to IS -875 part III and live load of 125 kg/m uniformly distributed load as per IS:875 Part-II. The profile system is based on capped curtainwall design and glass is held all around by mechanical pressure plate and cap with microwave cured EPDM gaskets in all four sides of glazing, with necessary brackets MS with HDG with three dimensional adjustment with serrations and serrated washers to arrest the wind load movement, anchor Fasteners, screws and fasteners with Non-staining weather sealant and Aluminium flashing sealed all around parameter inside and outside to seal the gaps between skylight and the building structure etc all complete required to perform as per specification and drawing in conjunction with item description.
The system shall include pressure equalization with minimum 2 barrier gaskets for improved weather performance, drainage at all floor levels, to accommodate building movements, thermal expansions & the seismic movements. The system shall be perform considering surface temperatures of 80-90 deg Cel & temperature differential of 25 deg cel without creating excess stress in the system.
The aluminium system consist of the extruded aluminium sections of alloy 6063 T5/T6 & tolerances confirming to DIN / EN standards from M/s. Jindal/Hindalco or approved equivalent make and manufacturer. The aluminium sections shall have approved shade and colour super durable powder coating with minimum 50 micron thickness. The non visible aluminium sections shall have approved chromatizing treatment. Including providing & fixing approved make EPDM Gasket ( Micro cured (online curing) with shore A hradness of 60-65), approved make non staining weather & structural sealant, SS-304 pan head screws, nut bolts, washers, SS-304 grade anchor fastners (M/s. Hilti or approved equivalent) etc complete. ( The weight of extruded aluminium sections only will be mesured for payment).
Providing, Supplying, assembling & installing at all levels, locations & floors, skylight glass having 17.52 mm laminated glass (8 mm thick heat strengthened clear glass+ 1.52 mm thick SGP (Sentry Glas Plus) interlayer + 8 mm thick heat strengthened clear glass) with digital printing on 70% area as per design including T&P, scaffolding and other incidental charges, wastages etc all complete as per approved shop drawings and specifications and as directed by the Engineer-in-Charge. (Note:- Skylight shall be measured to the overall dimension on external face as fixed on site (Actual size) provided and fixed in position, shall be measured in sqm.
Providing & fixing in position Structural steel work using mild steel for skylight system as per drawing & design using sections such as pipes, angles, plate, tee, channels etc conforming to IS standards including providing & applying blast cleaned surface, zinc rich epoxy primer (75 micron), epoxy barrier (125 micron) and polyurethene finish (50 micron) for exposed surfaces including providing & fixing approved quality, size, shape SS-304 anchor fastners for fixing the system with RCC members , SS nut bolt for connections cutting, welding etc complete all as per specifications, drawings & as directed by the Engineer-in-Charge. {The weight of structural steel sections only will be mesured for payment}).
SS support for Green Wall with SS String: Providing, supply, fabrication, installing, fixing, testing, cleaning, protection and handing over the SS support for Green Wall with SS String System, at all levels, locations, floors as per approved drawings including all labour, material, wastage, transporation, fixing in position, scaffolding etc complete all as per specifications, drawings and as directed by the Engineer-in-Charge.
Providing & fixing in position Stainless steel work using SS-304 grade Jali / Mesh (100 mm X 100 mm) using 4 mm thick SS string as per drawing including fixing in position with MS structure etc complete all as per specifications, drawings & as directed by the Engineer-in-Charge. {The weight of stainless steel sections only will be mesured for payment}).
Providing & fixing in position glavanised structural steel work for green wall using structural steel sections such as angle, channel, flat, pipes, hollow section and including providing & fixing approved shape, size, SS anchor fastners to fixing system with RCC menbers of structure including providing & applying one coat of zinc chromate primer and two coats of approved make, shade & colour sytnthetic enamel paint etc complete all as per specifications, drawings & as directed by the Engineer-in-Charge. {The weight of structural steel sections only will be mesured for payment}).
Providing & fixing in position heavy quality FRP bucket (UV resistant) of below mentioned size, at all floors, levels & location having approved colour & shade, including labour, material, fixing arrangements, screw, washer, scaffolding etc complete all as per specifications, drawings & as directed by the Engineer-in-Charge.
1200mm L x 300mm B x 750 mm H, wall thickness minimum 4 mm.
900mm L x 300mm B x 750 mm H, wall thickness minimum 4 mm.
1200mm L x 400mm B x 600 mm H, wall thickness minimum 4 mm.
950mm L x 650mm B x 500 mm H, wall thickness minimum 4 mm.
Total of PART I-M : Facade work
PART I-N : Interiors work
Providing & fixing stainless steel work for pipe hand rail at staircase, Entrance Ramp and other stainless works such as spool pieces, pipe sleeves etc, at all floors, levels & location conforming to SS-304 grade of steel preferably schedule-10, using SS pipe in horizontal at top, vertical, inclined including solid pipes as per drawing or as per pattern & design approved by EIC and including necessary S.S bend, tees, Embeded plates, nuts, SS bolt,necessary welding, anchoring with SS anchor fastner of M/s Hilti, grinding, buffing, polishing and fixing in concrete / wall with S.S lugs, making pockets, concreting, making good the surfaces etc. as per specifications, drawings and as directed by Engineer-in-Charge. ( Note:- For payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) Please refer Additional Notes.
Providing and fixing following type of approved quality 12mm thick toughened glass panes of approved colour, shade and design for railing of staircase at all floors and levels windows/ ventilators, of all geometrical shape of M/s. Saint Gobain fixing with stainless steel satin finish holder as shown in drawing ( stainless steel holder to be paid separately under relevant item) including rounding the edges cost of all fittings and fixtures, watages labour , scaffolding etc.all complete as per complete generally as per drawings specifications and as directed by the Engineer in Charge.
Providing and fixing in position at all levels, location & floors, the factory made single extruded WPC (Wood Polymer Composite) solid plain board having 10 mm thickness, of approved shade & colour for railing of balcony & straircase having 125 mm width (approx) including fixing with stainless steel railing work using SS screws, nuts, bolts etc (stainless steel railing work to be paid separately under relevant item) including rounding the edges, cost of all fittings and fixtures, watages, labour , scaffolding etc complete all as per specifications and as directed by EIC.
Supplying, providing, placing, installing and fixing in position in true line and level as per detail drawing approved by EIC, MODULAR TOILET PARTITIONS along with specified brand or approved equivalent of size as per detail drawings, Floor mounted including providing and fixing all accessories, fixtures, fastenings, hinges, anchorages, all hardware with approved locking arrangement as recommended by manufacturer and as approved by EIC etc. complete as directed, at all levels. Item description: Cubicle size - 900mm x 1550mm x 2100 mm (height is including 150 mm gap from bottom). Colour of Boards : As per the Shade card - approved by EIC. Thickness of Compact Sheet : 12mm (min.). Material:Compact Laminate in panels. Made from solid grade compact high-pressure laminate as per IS:2046 and EN438- manufactured under high specific pressure > 5 MPa and temperature 120° C with bunch of kraft papers impregnated with thermosetting phenolic resin and decorative papers made of cellulose fibre impregnated with thermosetting melamine resin which provide superior scratch, abrasion,
heat, chemical, impact, graffiti & moisture resistance along with anti-bacterial properties. Panels have a black core that when machined, presents a distinctive black edge. Size of panels to be as per drawing. Door size - 1750 x 600(H X W) All doors will be of single colour and made of 12 mm thick HPL compact panel. The doors will have chamfered edges. Each door will be supported by 3 stainless steel made hinges affixed to the pilasters. Stainless steel made coat hook and Lock set (comprised of Thumb turn and occupancy indicator) are provided with each door. All the doors will be routed at the vertical ends and the rubber sponge lining will be incorporated at the routed ends. Pilaster dimension - 1830 x 300 (H X W) All pilasters will be made of 12 mm thick HPL compact panel with chamfered edge and completed with stainless steel made thumb turn lock set. Pilasters will be anchored to the floor using stainless steel made adjustable legs. All pilasters will be routed at their vertical ends to facilitate closure of doors. The bottom gap is 150-100 mm.
Dividers - 1775 x 1550 (H X W) All intermediate partitions or dividers will be made of 12 mm thick HPL compact laminate panels. They are affixed with stainless steel made U-channel at their ends for ultimate stability of the system. Hardware and Accessories Details : below mentioned all accessories – Stainless Steel - 304 Grade a) Adjustable Pedestal Footing of base diameter 60 mm made from Stainless steel grade 316 giving an adjustable height of 100mm to 150mm. Surface finish to be matt type. b) SS U -Channel c) SS F Channel d) SS Door Stopper Channel e) SS Top Rail with circular cross section (Diameter 32mm). Surface finish will be mirror type. f) SS Coat Hook with rubber stopper made from Stainless steel grade 304. Surface finish to be lacquer type. g) SS Privacy Thumb turn c/w Occupancy Indicator made from Stainless steel grade 304. Surface finish to be lacquer type.
h) Round Door knob diameter 30 mm with grooves for better hand grip made from Stainless steel grade 304. Surface finish to be matt type. I) SS Spring Loaded Butt Hinges with Cover j) Anti-noise rubber padding of thickness 2 mm and width 10 mm k) Screws & Wall Plugs. Stainless steel grade 304 screws. l) Tubular panel holder made of stainless steel grade 304. Surface finish will be lacquer type. m) Corner joinery section made from Stainless steel grade 304. Surface finish to be brush type. A thin plastic film pasted for surface protection. Size to be 35mm x16.4mm x 0.8 mm. n) Wall joinery section with hamming profile made from Stainless steel grade 304. Surface finish to be brush type. A thin plastic film is pasted for surface protection. Size to be 21mm x 16mm x 0.8 mm.
Supplying, providing, placing, installing and fixing in position in true line and level as per detail drawing and approved EIC, Modular Toilet Urinal partition UMP along with specified brand or approved equivalent of size as per detail drawings, Colour of Boards : As per the Shade card - approved by EIC. Item description: The Urinary Panel has a 12 mm thick High Pressure Laminates (HPL) Compact Board, with a recommended panel width dimensions of 400-500 mm. The size of the panel is 500 mm (W-Top) X 400 mm (W-Bottom) X 1200 mm (H), with the overall height of 1200 mm. Final Size of Partitions : As per drawing given - shop drawings approved by EIC. Accessories Details : below mentioned all accessories – Stainless Steel - 304 Grade made 2 brackets used to fix each urinal panels to the walls.
Providing and fixing false ceiling with frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm
high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound, jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint all as per specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge. Note:- The entire grid system shall be designed to bear a distributed load of minimum 15 kg/sqm. The rate shall include providing necessary openings for light fixtures, diffusers, trap doors etc to be made as per layout drawings. The work shall be carried out as per directions of Engineer-in-charge. (Only false ceiling area will be measured for the purpose of payment)
Using 12.5 mm thick tapered edge gypsum plain board conforming to IS: 2095- (Part I) (Board with BIS certification marks)
Using 12.5 mm thick tapered edge moisture resistant gypsum plain board conforming to IS: 2095- (Part I) (Board with BIS certification marks)
(Acoustic Gypsum board False Ceiling) Using Fully Perforated Gypsum Board of size 1200 x 2400x12.5 mm having approx 16 % perforated area with perforation size and pattern, having 8 perforation sets per board and each set of size (487 X 487 mm), 56.5 mm border and 113 mm centre band or as approved by the Engineer-in-charge and as per manufacturer's specification, (with all 4 side tapered and backed by acoustical tissue with NRC value not less than 0.65)
Providing & fixing of Perforated Aluminium U-shaped Panel ceiling of approved colour powder coating consisting of 2mm dia perforated Panel 50mm wide x 100mm deep x 0.7mm thick (TCT) with NWC ( Non-Woven Cloth) & glass wool of 48kg/M2 and 50mm thick to be placed to achieve the maximum NRC value of 0.9, square edges, panel length up to 5000 mm, Powder Coated Roll formed, Panel shall be clipped to G.I. panel carrier of 20 mm wide x 45mm deep x 0.6 mm thick in standard length of 3000 mm black with cut outs to hold the panels in a module of 150 mm (width of clear gap 100mm), The Carrier shall be suspended by means of G.I. suspension rod 4mm diameter and a Galvanised Suspension Butterfly Clip at a distance of 1200mm. Hangers fixed to the roof by ceiling fasteners, Panel lengths up to maximum 5000 mm. Edge profiles or wall angles are 24 mm x 24 mm x 0.3 mm thick and match the colour of the panels. Paint Finish: Aluminium panels shall be Interior grade powder coating not less than 50 microns for maximum bond between metal and paint etc complete all as per specifications and as directed by the EIC. (Only false ceiling area will be measured for the purpose of payment)
Linear Aluminium Roll formed System with interlocking “F” Carrier (200 mm). Providing and fixing Green Pro Certified Exterior Aluminium 200mm (0.7mm) Plain Aluminium Panel Ceiling of approved colour, 200F consisting of panels 200mm wide x 17mm deep x 0.7mm thick, panel length up to 6mtrs, the coated coil is passed thru Six Hi configuration roller levelling process to ensure the flatness of the coil. The Coil is Coated on a Continuous Paint Line, Double baked and Roll formed from enamelled Corrosion Resistance Aluminium Alloy AA3105 (Al. Mg) for higher strength and good Roll Forming characteristics. Panel shall be clipped to a baked enamelled Aluminium Panel Carrier of 34.5mm wide x 48mm Deep made of 0.90 mm thick in standard lengths of 5mtrs made of Double baked enamelled Aluminium Alloy AA 3005 (Al. Mg) colour Black with cut outs to hold the panels in a module of 200mm at a distance of 1.2mtrs c/c. The panel carrier shall be suspended by means of G.I. suspension rod 4mm diameter and galvanised spring clip at a distance of 1.5 mtr. c/c.
Paint Finish: Aluminium panels shall be chromatised for maximum bond between metal and paint, stove enamelled twice under high temperature on one side with full primer on the rear side, The paint system shall be Luxacote Hybrid or PVDF finish to withstand high UV and external conditions, other side (inner side) with a primer coat on a Continuous Paint Line. etc complete all as per specifications and as directed by the EIC. (Only false ceiling area will be measured for the purpose of payment)
Providing and fixing lay in false ceiling 600 x 600 m corrosion resistant Aluminium magnesium alloy metal panel fixed in 24 mm 'T' frame work of module 600 x 600 mm, Panels shall be manufactured in approved colour in 0.70 mm thick Aluminium alloy 3105 with square edges Tiles to be stove enamelled on a continuous application for pre-treatment. The coils to be go through 4 stages of pre treatment three times of oven baked through conversion coating, priming and finish coat ensuring superior adhesion, high corrosion resistance and good colour stability.The coils to be painted on both sides after degreasing. inside surface to have a primer of 5 microns and a coat of natural colour of 5 microns, exposed surface to have a primer of 5 microns, binder of 5 microns and a top coat of approved colour 15 microns. Grid system for fixing ceiling tiles shall comprise of tees. The 24mm main tee runers shall be suspended at an interval of 1200mm centre to centre. The 24mm cross tee runner shall be suspended at an interval of 600mm centre to centre and further supported with 24mm cross tee with inter locking arrangements to form a Grid of 600mm x 600m.
The main tee shall be supported by means of 4mm G.I.rod from slab / roof. The suspension shall be provided at 1200 to 1500mm centre to centre. Provision for lights, diffusers etc to be made including extra supports wherever necessary. Measurements shall be as per actual area of false ceiling.
Using Unperforated corrosion resistant aluminium magnesiusm alloy metal panel of size 600 X 600 mm (Approx.)
GYPSUM BOARD PARTITIONS: Providing and fixing partition upto ceiling height consisting of G.I. frame and required board, including providing and fixing of frame work made of special section power pressed/ roll form G.I. sheet with zinc coating of 120 gms/sqm(both side inclusive), consisting of floor and ceiling channel 50mm wide having equal flanges of 32 mm and 0.50 mm thick, fixed to the floor and ceiling at the spacing of 610 mm centre to centre with dash fastener of 12.5 mm dia meter 50 mm length or suitable anchor fastener or metal screws with nylon plugs and the studs 48 mm wide having one flange of 34 mm and other flange 36 mm and 0.50 mm thick fixed vertically within flanges of floor and ceiling channel and placed at a spacing of 610 mm centre to centre by 6 mm dia bolts and nuts, including fixing of studs along both ends of partition fixed flush to wall with suitable anchor fastener or metal screws with nylon plugs at spacing of 450 mm centre to centre, and fixing of boards to both side of frame work by 25 mm long dry wall screws on studs, floor and ceiling channels at the spacing of 300 mm centre to centre.
The boards are to be fixed to the frame work with joints staggered to avoid through cracks, M.S. fixing channel of 99 mm width (0.9 mm thick having two flanges of 9.5 mm each) to be provided at the horizontal joints of two boards, fixed to the studs using metal to metal flat head screws, including jointing and finishing to a flush finish with recommended jointing compound, jointing tape, angle beads at corners (25 mm x 25 mm x 0.5 mm), joint finisher and two coats of primer suitable for board as per manufacture's specification and direction of engineer in charge.
122 mm overall thickness partition with 12.5 mm thick double skin fire rated Glass Reinforced Gypsum (GRG) plaster board conforming to IS: 2095: part 3 (Board with BIS certification marks) having 2 hr fire rating and including providing & fixing 50 mm glasswool of density 20 Kg/cum, shall be placed in metal frame work with the help of holding clips.
154 mm overall thickness partition with 15.0 mm thick double skin fire rated Glass Reinforced Gypsum (GRG) plaster board conforming to IS: 2095: part 3 (Board with BIS certification marks) having 2 hr fire rating and including providing & fixing 50 mm glasswool of density 20 Kg/cum, shall be placed in metal frame work with the help of holding clips.
Total of PART I-N : Interiors work
PART I-O : Signage work Note:- The agency shall quote rates by considering cost of name print, sign printing with approved colour, shade, font, size having flat bed UV resistant print including vinyl sticker, printing, material etc complete, the all items in this section are inclusive of priting work as directed by EIC.
Informative Siganage Work
Providing and fixing signs made using minimum 1 mm thick modular Aluminium extrusions sheet having minimum 15 micron premium grade anodizing, at all floors, levels & loactions, the aluminium profile click fitted on plastic injection moulded black encaps at both ends including cost all injection moulded endcaps, fixing, screws, double sided tape, labour, material, scaffolding, flat bed UV resistant printing etc complete all as per specifications, drawings & as directed by the EIC.
Door name plate sign, having size 400X125X12 mm, door/wall mounted type
Door name plate sign, having size 300X125X12 mm, door/wall mounted type
Door name plate sign, having size 200X125X12 mm, door/wall mounted type
Wall mounted sign, having size 300X125X12 mm, door/wall mounted type
Providing and fixing signs made using minimum 1 mm thick modular Aluminium extrusions sheet having minimum 15 micron premium grade anodizing, at all floors, levels & loactions, the aluminium profile with side track and common tracks click clips for panel fittings fitted on plastic injection moulded black encaps at both ends including cost all injection moulded endcaps, click clips, side tracks, fixing, screws, double sided tap, labour, material, scaffolding flat bed UV resistant printing etc complete all as per specifications, drawings & as directed by the EIC.
Floor directory sign, having size 750X1500X15 mm, wall mounted type
Building directory sign, having size 1000X2000X15 mm, wall mounted type
Providing and fixing signs made using two aluminium sheet each sheet minimum 1 mm thick modular Aluminium extrusions sheet having minimum 15 micron premium grade anodizing, at all floors, levels & loactions, the double sided sign with two aluminium profile connected with each other including cost all injection moulded endcaps, fixing, screws, double sided tap, labour, material, scaffolding, flat bed UV resistant printing and icluding providing & fixing 2 mm dia multistrand G.I. wire for hanging (Upto 1.5 m in length) wit SS suspension clips, with adjustment mechanism etc complete all as per specifications, drawings & as directed by the EIC. (Ceiling suspended sign, having size 900X187X20 mm)
Providing and fixing signs made using minimum 1 mm thick modular Aluminium extrusions sheet having minimum 15 micron premium grade anodizing, at all floors, levels & loactions, the aluminium profile click fitted on plastic injection moulded black encaps at both ends including cost all injection moulded endcaps, fixing, screws, double sided tap, labour, material, scaffolding, flat bed UV resistant printing, vinyl wrapping, design of profile etc complete all as per specifications, drawings & as directed by the EIC. (Toilet door sign, having size 156X156X12 mm, door/wall mounted type and Photoluminescent)
Mandatory Siganage Work
Providing and fixing signs made using minimum 1 mm thick modular Aluminium extrusions sheet having minimum 15 micron premium grade anodizing, at all floors, levels & loactions, the aluminium profile click fitted on plastic injection moulded black encaps at both ends including cost all injection moulded endcaps, fixing, screws, double sided tap, labour, material, scaffolding, flat bed UV resistant printing etc complete all as per specifications, drawings & as directed by the EIC.
Lift mandatory sign, having size 250X187X12 mm, wall mounted type and Photoluminescent
Fire extinguisher sign, having size 300X156X12 mm, wall mounted type and Photoluminescent
Total of PART I-O : Signage work
PART I-P : Area development work
Construction of granular sub - base by providing close graded material, mixing in a mechanical mix plant at OMC, carriage of mixed material to work site, spreading in uniform layers with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per MORTH specifications 401. (The material of the GSB layer confirming Table 400.1 shall be spread in layers of uniform thickness of 200 mm compacted thickness).
Providing and fixing 80 mm thick (min.) factory made paver blocks of specified finish (shot blasted etc), approved make and colour, shade, size, shape laid in pattern manufactured with cement concrete grade not less than M-40 and conforming to IS:15658, including providing & laying 20 mm thick bedding of cement mortar (using ready mix mortar having cement: sand, 1:4) finishing to line, level and slope, finally filling the joints with matching cement mortar and cleaning the surface etc. complete all as per specification and as directed by the Engineer- in- Charge.
Providing and fixing 60 mm thick (min.) factory made paver blocks of specified finish (shot blasted etc), approved make and colour, shade, size, shape laid in pattern manufactured with cement concrete grade not less than M-35 and conforming to IS:15658, including providing & laying 20 mm thick bedding of cement mortar (using ready mix mortar having cement: sand, 1:4) finishing to line, level and slope, finally filling the joints with matching cement mortar and cleaning the surface etc. complete all as per specification and as directed by the Engineer- in- Charge.
Providing and laying design mix cement concrete in road, pavement etc of grade specified below using ready mixed concrete from batching plant, using graded stone aggregate of 20 mm nominal size including compaction & finishing with screed board vibrator, vacuum dewatering process and finally finished by floating, brooming with wire brush, including steel form work with sturdy M-S channel sections including curing and providing and filling construction joints and dummy joints with approved joint filler primer or equivalent including rounding of the edges and filling the grooves 10 x 25 mm deep at top for construction joints and 10 mm x 50 mm deep at top for dummy joints (spacing as per IRC Code) with joint sealing compound including making necessary arrangements for expansion joints and including Providing and fixing mild steel dowel/tie bars of dia, spacing & length as per IRC approved make including greasing of ends and including providing and mixing hardening compound of approved quality as per manufacturer's specification in cement concrete etc complete all as per specifications and as directed by Engineer-In-Charge. (Using Cement Concrete of M-30 grade)
Providing and fixing Granite cobble stone of size 100 X 100 X 100 mm thick, in approved pattern using granite stone of approved colour & shade, including providing & laying 20 mm thick bedding of cement mortar (using ready mix mortar having cement: sand, 1:4) finishing to line, level and slope, finally filling the joints with matching cement mortar and cleaning the surface etc. complete all as per specification and as directed by the Engineer- in- Charge.
Providing & laying machine cut & River washed finish mimimum 25 mm thick Tandoor stone of approved colour at all floor & location in necessary cement mortar bedding /backing, close jointed & grouted with matching cement slurry and rounding of edges, finished to line, level,curing etc. as required, including cutting of stone slab, wastage, making cut outs, grooves wherever required, etc. complete all as per specifications, drawings and as directed by the Engineer in charge. Note: Top exposed surface on plan &exposed vertical finished face shall be measured for payment in Sqm.
In flooring with River washed finish mimimum 25mm thick Tandoor stone of approved colour as per drawing laid over & including 20mm thick cement mortar1:4 ( 1 cement : 4 coarse sand) bedding. (Using ready mix mortar) including cement slirry at 4.40 Kg/Sqm over bedding and matching slurry with white cement at 2.20 Kg/Sqm for grouting the joints.
25 mm thick one side River washed finish mimimum 25 mm thick Tandoor stone of approved colour, shade and surface finish for dado/skirting/Riser stone slabs of various sizes in pattern including 12 mm thick 1:4 cement mortar (Using ready mix mortar) backing,
Providing & laying machine cut & Leather finish mimimum 25mm thick Tandoor stone of approved colour at all floor & location in necessary cement mortar bedding /backing, close jointed & grouted with matching cement slurry and rounding of edges, finished to line, level,curing etc. as required, including cutting of stone slab, wastage, making cut outs, grooves wherever required, etc. complete all as per specifications, drawings and as directed by the Engineer in charge. Note: Top exposed surface on plan &exposed vertical finished face shall be measured for payment in Sqm.
In flooring with Leather finish mimimum 25mm thick Tandoor stone of approved colour as per drawing laid over & including 20mm thick cement mortar1:4 ( 1 cement : 4 coarse sand) bedding. (Using ready mix mortar) including cement slirry at 4.40 Kg/Sqm over bedding and matching slurry with white cement at 2.20 Kg/Sqm for grouting the joints.
Providing and laying at or near ground level factory made kerb stone (Flat top / Half Batter / Dropper / radius / Angle kerb or other approved shape) of minimum M-25 grade cement concrete, of approved manufacturer in position, having shape & approx size ( 600 X 450 X 150 mm / 600 X 300 X150 mm /300X300X 150 mm) / or as directed by EIC / as per IS:5758, to the required line, level and curvature, jointed with ready mix cement mortar 1:3 (1 cement: 3 coarse sand) as specified, including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm) & including Providing & laying 200 mm wide and 75 mm thick PCC 1:2:4, including making drainage opening wherever required complete, and painting in pattern with approved shade & colour synthetic enamel paint two coat over a coat of primer etc. as per direction of Engineer-in-charge (Length of finished kerb edging shall be measured for payment. Only Kerb stone in cum measured for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge).
Galvanised Structural steel work in MS Bright bars using joists, bars, tubes, flats, SHS, RHS and other sections, welded and / or bolted in built up sections for Gates, structural steel floors, frame works, monorails and other structures including supplying, cutting, welding, fabricating, bending to shape (Curve and as approved design / any shape as per drawing) hoisting/erecting, wastages, fixing in position, scaffolding, bracing, providing and fixing in position with necessary masonry / RRM / RCC fasteners, making holes / chases wherever required and fixing / embedding in position in concrete / brick work / RRM with necessary heavy duty holdfasts /screws & rawl plugs and finishing the concrete/ brick work /RRM after fixing / embedding including getting hot dip galvanising treatment to all MS work in approved galvanizing plant etc. and applying two coats of as per approved by Architect for approved shade synthetic enamel paint over a two coats a priming coat of approved zinc chromate steel primer etc. complete all as per specifications, drawings and as directed by the Engineer-In-Charge.
Rubble Stone pitching, 230 mm thick using spotless stones including supply of stone, preparation of surface, setting the stone to the proper line and slopes, Grouting the joints in stone pitching 230 mm thick with ready mix mortar having cement mortar 1:4, and pointing the surface with the same mortar, curing including all labour, material etc complete all as per specification and as directed by the Engineer in charge. (Weep holes / pipes , if provided shall be mesured and paid under relevant item)
Providing and laying 200 microns thick High density polyethylene sheet (HDPE) manufactured by approved manufacturer between pitching and embankment slopes on which pitching is laid to prevent escape of the embankment material through the voids of the stone pitching & Lake bottom necessary overlapping of minimum 200mm and sealing with suitable tape, the HDPE sheet shall be laid after thorough cleaning of the surfaces to make sure there will not be any protrusions from the surface which shall cause damage to the sheet, the rate shall include for cost of materials, wastages, labour, tools & plants, loading and unloading charges, transportation, cleaning, all other incidental charges, etc ., complete with all leads and lifts as per specifications and drawings at all levels and as directed by the Engineer in Charge.
Treilles - Providing & fixing in position glavanised structural steel work using structural steel sections such as angle, channle, flat, pipes, hollow section and including providing & fixing approved shape, size, SS anchor fastners to fixing system with RCC menbers of structure including providing & applying one coat of zinc chromate primer and two coats of approved make, shade & colour sytnthetic enamel paint etc complete all as per specifications, drawings & as directed by the Engineer-in-Charge. {The weight of structural steel sections only will be mesured for payment}).
Aluminium Section System for Trellies: Providing, supply, fabrication, installing, fixing, Aluminium section system, at all levels, locations, floors as per approved drawings including all labour, material, wastage, transporation, fixing in position, scaffolding, the aluminium sections shall have approved shade and colour super durable powder coating with minimum 50 micron thickness. The non visible aluminium sections shall have approved chromatizing treatment. etc complete all as per specifications, drawings and as directed by the Engineer-in-Charge. {The weight of extruded aluminium sections only will be mesured for payment}).
Providing and fixing various types and sizes of signage and wayfinding for outdoors, (as specified below) Signage with Vinyl printing and lettering and including complete fabrication, arrangement including cost of subframe, installation over provided concrete pedestals, at all levels, scaffolding etc complete all as per specifications, drawings and as directed by the Engineer in Charge.
Using 3.0 mm thick ACP sheet with 25 mm thick alumnium frame in Signage of minimum size 1.65m X 0.90m.
Using 3.0 mm thick ACP sheet with 25 mm thick alumnium frame in Signage of minimum size 1.05m X 0.90m.
Building Identification Plate of minimum size 1 m X 0.2 m size using 0.8mm thick SS plate with etching, for Front media including Polypropylene (PP) corners used to create frame and Double sided tape to hold the front media, including Providing & fixing with 25mm depth using Aluminium extrusions (Alloy 6060) with Anodizing (Thickness minimum 15 microns).
Providing & fixing at all heights, SS-316 LED Letter for Logo & institute Name (as per approved pattern, and shape), Logo Size 2ft Height, Letter Size 1ft height each letter, having thickness of 1.6 mm SS plate including providing & fixing LED module, water proof power supply arrangmnets, installation using heavy duty chemical anchor fastners, design propotinately as per drawing & as directed by EIC. (Institute Name : TIFR and Institute Logo as per drawing)
Providing and fixing in Stainless steel Floor Mounted Dustbin with dimensions and design as per drawing, in SS 304, Dual bins with 50 liters each having Matt / Mirror Finish the SS sheet thickness not less than 3 mm for all members, using SS plate, Perforated plate, pipes, angle etc including required foundation, anchor bolts etc complete all as per specifications, drawing and as directed by EIC. (Note:- Only Stainless steel members will be measured for payment)
Supplying , filling, spreading & leveling pea gravel of size range of 6 mm to 10 mm of approved colour, shade and combination using grey / brown and other approved shade & colours,, in required thickness, for all leads & lifts, transporation, spredaing etc all complete as directed by the Engineer-in-charge.
Horizonal drilling of earth (Up to 500mm dia) using mechanical method and laying of RCC hume pipe of up to 450 mm dia pipe in drilling hole at the depth as per invert level of pipe line complete in all respect as directed by EIC. Note : 1) Item inlcudes mobilizing the mechanical horizontal driller machine, all tools and tackles and laying of pipe in the drilled hole, the pipe shall be measured & paid under relevant item).
Shifting of existing boulders from various location within campus to directed place and fixing for decorative purpose including loading, unloading, transportations, placing in position, including necessary ready mix mortar as required etc complete all as per drawing & direction of EIC.
Having approx size from 300X300X300 mm and upto 500X500X500 mm.
Having approx size from more than 500X500X500 mm and upto 1000X1000X1000 mm.
Having approx size from more than 1000X1000X1000 mm and upto 1500X1500X1500 mm.
Having approx size from more than 1500X1500X1500 mm and upto 2000X2000X2000 mm.
Having approx size from more than 2000X2000X2000 mm and upto 3000X3000X3000 mm.
Dismantling / demolishing work by manual /Chiselling/ mechnical means, carefully without damaging & disturbing adjacent structures, at all levels, locations & floors including labour, machine, loading, unloading, transportation, stacking of serviceable material at directed place & disposal of debris & unserviceable material within campus at directed place, scaffolding etc complete all as per specifications and as directed by Engineer-in-Charge.
Plain Cement Concrete (PCC)
Reinforced Cement Concrete (RCC) including cutting of steel reinforcement bars by cutter, gas welding etc
Brick masonry work in cement mortar including cement mortar plastering / pointing work
Tile/stone / granite work in dado/Skirting/ flooring, including backing / bedding cement mortar
Removing rough/ smooth finished interlocking paver blocks of 60/80 mm thickness for pavement in footpath / parking at required loactions including cleaning the surface, stacking and storing serviceale materials at directed place within campus and disposing off the debris at directed place within campus etc. complete all as per specification and as directed by the Engineer- in- Charge.
Removing the existing kerb stones from location with base mortar & including cleaning the surface, stacking and storing serviceale materials at directed place within campus and disposing off the debris at directed place within campus etc. complete all as per specification and as directed by the Engineer- in- Charge.
Total of PART I-P : Area development work
PART I-Q : Tensile Structure
Supplying, Providing, Fabricating, Assembling, hoisting, erecting and placing in position MS Built-up section/Tubular Structure ( MS built-up section :-Rolled section & plates confirming to IS 2062 Grade Yst 350,Tubular Structure:- made from Steel hollow sections, ISI marked from SAIL / RINL / TATA/JINDAL, conforming to IS 1161/4923/1239, Minimum Yst 240 thickness upto 10mm ) in the profile shape as per drawings with special plate connector, pinion joints, Plates, hollow sections etc. With special plate connectors, pinion joints, plates, hollow sections including preparation of detailed fabrication, erection shop drawings of Structural steel work from design drawings, including transportation, cutting, wastage, threading, machining, leads and lifts upto all heights, tools and plants and necessary scaffolding etc. required for all operations involved to make structure of Tensile Membrane shade, the tubular structure system with plate connectors, pinion joints, etc.
is to be provided, the structure has to be provided as per conceptual drawings of Tensile fabric profile , including all arch beam, curved lateral beams and bracings, vertical support columns, nodal joints, ,bases of columns and high tensile bolts of grade not less than 10.9 having black phosphate coating, the complete structure to be Hot Dip Galvinized along with one coat of epoxy primer and two coats of Polyurethane paint on steel work at all locations prepared by sand blasting in required minimum 310 micron DFT (dry film thickness) for each coat as specified etc complete all as per specifications, drawings and as directed by EIC.
Supply, Fabrication and Installation of Membrane Panels & steel Cables and GI corner fittings nuts and bolts and associated accessories with PVC/ PVDF coated membrane works. Membrane shall be High Translucent PVC/ PVDF coating with HT Polyester Yarns of 1100 Dtex and Type 2 from Serge Ferrari (1002s2) or Eauivalent with minimum Weight of 1050 g/m2, minimum Tensile Strength (Warp/ Weft) - 4200/ 4000 N/5cm, minimum Tear Strength (Warp/ Weft) - 550/500 N. Fabric Flame Retadancy Rating to be Euro Class - Bs2, d0, Micro Organism Resistance and Warranty of 15 years. The design complies with the requirements of BS and, EU Standards. The tensioned membrane structure shall include engineering design of structural members and accessory parts. Membrane system shall include PVC/ PVDF coated Membrane Fabric, Wire Ropes and Cables, Shackles, Rigging Screws, Clamps and tensioning hardware as per specification, drawings and as directed by EIC.
Providing, fabricating and installing of Tensile Cable Net Structure, including fabrication and installation of fabric canopy as per design and details, using coloured 0.6 mm thick architectural structural fabric, both sides Weldable coated with Ferrari FT 381 550 g/sqm. or Similar Membrane With Precontrant Technology , Tensile Strength Warp/ Weft: 3300/ 3300N/ 5cm - EN ISO 1421,Tear Strength Warp/ Weft:-800/ 900N - DIN 53.363, Pororsity (Openess Factor)-28%meeting the EN ISO 1421 standard in parameters of tensile strength, DIN 53.363 in tear strength, and adhesion, meeting the DIN 4102 1 standard for flame retardancy, having polyester woven scrim and PVC layers, HF heat sealed at joints and hot air or cyanoacrylate pasting other required locations, with PVC fabric interlay at joints, including providing & fixing necessary required SS nuts, bolts, SS accessories, aluminium clamping bars / extruded sections with Stailness steel cables other required hardware as required per design & drawing, (standard 10 yrs fabric warranty to be provided) etc. complete all as per specifications, drawing & as directed by EIC. (Total area of work in plan only will be measured for payment)
Total of PART I-Q : Tensile Structure
PART I-R : Softscape Work
Excavation for foundation by mechanical / manual means in all kind of soils & soft rock up to 0.9mtx 0.9 mt x 1.5mt. depth including backfilling, shoring, strutting dewatering as necessary, sorting out and stacking of useful materials and disposing of the surplus excavated material within campus etc complete all as per specifications and as directed by EIC.
Trees: Supplying and planting of shade, ornamental, fruit, flowering trees, small, medium and large specimens suitable for region, adaptable to low water, as per under noted varieties, with ht. as specified in drawings including excavation of pit of size 0.9 m x 0.9 m x 0.9 m filling the pit with soil mixture etc. as per specifications and as directed complete in all respect including watering and nurturing the trees. The trees may be planted individually in rows or in cluster as per direction in drg. and all plant material and its sizes and height/girth and crown should be shown to the EIC & written approval to be sought before planting.
Albizia lebbeck; 400 mm polybag size; 3500 mm height; As per drawing
Neolamarckia cadamba; 400 mm polybag size; 3000 mm height; As per drawing
Alstonia scholaris; 300 mm polybag size; 3000 mm height;As per drawing
Pongamia glabra; 300 mm polybag size; 3000 mm height; As per drawing
Schleichera oleosa; 400 mm polybag size; 3500 mm height; As per drawing
Putranjiva roxburghii; 350 mm polybag size; 3200 mm height; As per drawing
Mesua ferrea ; 300 mm polybag size; 3000 mm height;
Terminalia cattappa ; 400 mm polybag size; 5000 mm height;
Mimusops elengi; 300 mm polybag size; 1500 mm height; As per drawing
Cassia siamea; 400 mm polybag size; 3000 mm height; As per drawing
Syzygium cumini; 400 mm polybag size; 4500 mm height; As per drawing
Bombax ceiba; 450 mm polybag size; 5000 mm height; As per drawing
Butea monosperma;450 mm polybag size; 5000 mm height; As per drawing
Moringa oleifera; 350 mm polybag size; 3500 mm height; As per drawing
Erythrina indica ; 400 mm polybag size; 4000 mm height; 6 m c/c distance
Prosopis cinererea; 400 mm polybag size; 3500 mm height; As per drawing
Tamarindus indica; 400 mm polybag size; 3500 mm height; As per drawing
Gliricidia sepium; 450 mm polybag size; 4500 mm height;As per drawing
Thespesia populnea; 450 mm polybag size; 3000 mm height; As per drawing
Polyalthia longifolia var Pendula; 350 mm polybag size; 6000 mm height; As per drawing
Acacia auriculiformis; 400 mm polybag size; 4000 mm height; As per drawing
Melia azedarach ; 400 mm polybag size; 3000 mm height;
Samania saman ; 500 mm polybag size; 6000 mm height;
Mitragyna parviflora; 450 mm polybag size; 4000 mm height; As per drawing
Couropita guianensis; 450 mm polybag size; 4000 mm height; As per drawing
Azadirachta indica; ; 500 mm polybag size; 6000 mm height;
Terminalia arjuna; 350 mm polybag size; 4500 mm height; As per drawing
Jacaranda mimosifolia ; 400 mm polybag size; 3500 mm height; As per drawing
Holoptelea integrifolia; 400 mm polybag size; 3500 mm height; As per drawing
Colvillea racemosa ; 400 mm polybag size; 3500 mm height; 6 m c/c distance
Ficus religiosa ; 500 mm polybag size; 6000 mm height; 12 m c/c distance
Ficus benghalensis; 500 mm polybag size; 6000 mm height; As per drawing
Dalbergia sisso; 450 mm polybag size; 4000 mm height; As per drawing
Techtona grandis; 350 mm polybag size; 3500 mm height;As per drawing
Madhuca longifolia; 350 mm polybag size; 3500 mm height; As per drawing
Peltophorum pterocarpum; 400 mm polybag size; 4000 mm height; As per drawing
Swietenia mahagoni; 400 mm polybag size; 4000 mm height; As per drawing
Millingtonia hortensis ; 350 mm polybag size; 3000 mm height;
Kigelia africana ; 400 mm polybag size; 4000 mm height;
Spathodea campanulata ; 400 mm polybag size; 4000 mm height; As per drawing
Parkia biglandulosa ; 400 mm polybag size; 4000 mm height; As per drawing
Adansonia digitata; 500 mm polybag size; 5000 mm height;As per drawing
Mangifera indica; 300 mm polybag size; 3000 mm height; As per drawing
Careya arborea; 400 mm polybag size; 3500 mm height; As per drawing
Cebia pentandra; 400 mm polybag size; 4000 mm height; As per drawing
Grewia tiliifolia; 400 mm polybag size; 3000 mm height; 6 m c/c distance
Delonix regea ; 450 mm polybag size; 5000 mm height; 12 m c/c distance
Saraca asoka; 400 mm polybag size; 3500 mm height; As per drawing
Tabebuia rosea ; 400 mm polybag size; 5000 mm height; As per drawing
Tabebuia aurea; 400 mm polybag size; 5000 mm height;As per drawing
Cassia fistula; 400 mm polybag size; 3000 mm height; As per drawing
Lagerstroemia speciosa; 300 mm polybag size; 2500 mm height; As per drawing
Crateva adansonii ; 300 mm polybag size; 2500 mm height; As per drawing
Cassia javanica; 300 mm polybag size; 2500 mm height; As per drawing
Plumera obtusa; 450 mm polybag size; 2500 mm height; As per drawing
Plumera rubra; 450 mm polybag size; 2500 mm height; As per drawing
Cordia sebastena; 300 mm polybag size; 2500 mm height; As per drawing
Lagerstroemia indica; 300 mm polybag size; 2500 mm height; As per drawing
Bauhinia variegata ; 300 mm polybag size; 2500 mm height; As per drawing
Ehretia laevis; 300 mm polybag size; 2500 mm height; As per drawing
Nyctanthes arbor-tristis; 350 mm polybag size; 2500 mm height; As per drawing
Magnolia champaca; 400 mm polybag size; 2500 mm height; As per drawing
Sterculia foetida; 400 mm polybag size; 2500 mm height; As per drawing
Melaleuca leucadendron; 350 mm polybag size; 2000 mm height; As per drawing
Gardenia jasminoides ; 300 mm polybag size; 1500 mm height;
Callistemon ; 350 mm polybag size; 2000 mm height; As per drawing
Calliandra tergemina ; 400 mm polybag size; 2500 mm height; As per drawing
Terminalia mantalay; 400 mm polybag size; 6000 mm height;As per drawing
Bauhinia variegata var. candida; 300 mm polybag size; 2500 mm height; As per drawing
Firminia colorata; 300 mm polybag size; 3000 mm height;As per drawing
Psidium guajava ; 300 mm polybag size; 2000 mm height; 6 m c/c distance
Citrus limon; 300 mm polybag size; 2000 mm height; 6 m c/c distance
Punica granatum; 300 mm polybag size; 2000 mm height; 6 m c/c distance
Manilkara zapota; 300 mm polybag size; 2000 mm height; 6 m c/c distance
Annona reticulata; 300 mm polybag size; 2000 mm height; 6 m c/c distance
Palms: Supplying and planting of palms as per under noted varieties, with ht. as specified in drg., including excavation of pit of size 0.9 m x 0.9 m x 0.9 m, removal of excavated earth to desired location filling the pit with soil mixture etc. as per specifications and as directed complete in all respect including watering and nurturing the trees. The trees may be planted individually in rows or in cluster as per direction in drg. and all plant material and its sizes and height/girth and crown should be shown to the EIC & written approval to be sought before planting.
Borassus flabellifer ; 500 mm polybag size; 2000 mm height; c/c NA
Phoenix sylvestris : 350 mm polybag size; 1800 mm height; c/c NA
Caryota urens: 500 mm polybag size; 1800 mm height
Hyphaene dichotoma: 350 mm polybag size; 1500 mm height; c/c NA
Cocos nucifera: 500 mm polybag size; 6000 mm height; c/c NA
Phoenix rupicola : 350 mm polybag size; 2000 mm height; c/c NA
Shrubs: Providing, planting and developing plants/ flower bed with under noted varieties of plants (both shade & sun loving), including excavating the soil to a depth of 450mm of required area as per plant species, removal of excavated earth to directed location, filling the excavated bed with approved soil mixture and manure, planting the approved variety plants, providing strong stack etc. as per specification and as directed complete in all respect, including watering and nurturing the plants.
Ground cover and low shrubs
Wedelia trilobata ; 200 mm polybag size;900 mm height; 0.30 m c/c distance
Rhoeo tricolor ; 200 mm polybag size;900 mm height; 0.30 m c/c distance
Chrysogonum ; 200 mm polybag size;900 mm height; 0.30 m c/c distance
Ophiopogon japonicus ; 200 mm polybag size;900 mm height; 0.30 m c/c distance
Syngonium ; 200 mm polybag size;900 mm height; 0.40 m c/c distance
Ipomea batatas ; 200 mm polybag size;900 mm height; 0.30 m c/c distance
Fern ; 200 mm polybag size;900 mm height; 0.45 m c/c distance
Angelonia purple; 200 mm polybag size;900 mm height; 0.45 m c/c distance
Angelonia White ; 200 mm polybag size;900 mm height; 0.45 m c/c distance
Medium Shrubs
Jasminum sambacum ; 200 mm polybag size; 900 mm height; 0.6 m c/c distance
Canna indica; 200 mm polybag size; 900 mm height; 0.6 m c/c distance
Eranthemum nigrum; 200 mm polybag size; 900 mm height; 0.6 m c/c distance
Jatropha ; 200 mm polybag size; 900 mm height; 0.6 m c/c distance
Plumbago; 200 mm polybag size; 900 mm height; 0.6 m c/c distance
Heliconia ; 200 mm polybag size; 900 mm height; 0.6 m c/c distance
Russelia ; 200 mm polybag size; 900 mm height; 0.6 m c/c distance
Pentas ; 200 mm polybag size; 900 mm height; 0.6 m c/c distance
Strelitzia reginae ; 200 mm polybag size; 900 mm height; 0.6 m c/c distance
Polianthes tuberosa ; 200 mm polybag size; 900 mm height; 0.6 m c/c distance
Pseuderanthemum reticulatum; 200 mm polybag size; 600 mm height; 0.6 m c/c distance
Alpinia Purpurata ; 200 mm polybag size; 900 mm height; 0.6 m c/c distance
Ecbolium viride - Green shrimp plant ; 200 mm polybag size; 900 mm height; 0.80 m c/c distance
Spider lily ; 200 mm polybag size; 900 mm height; 0.85 m c/c distance
Strelitzia nicolai ; 200 mm polybag size; 900 mm height; 0.8 m c/c distance
High Shrubs
Caesalpinia pulcherrima ; 200 mm polybag size; 900 mm height; 0.9 m c/c distance
Stachytarpeta ; 200 mm polybag size; 900 mm height; 0.9 m c/c distance
Gardenia ; 200 mm polybag size; 900 mm height; 0.9 m c/c distance
Barleria cristata ; 200 mm polybag size; 900 mm height; 0.9 m c/c distance
Hamelia patens ; 200 mm polybag size; 900 mm height; 0.9 m c/c distance
Mussenda ; 200 mm polybag size; 900 mm height; 0.9 m c/c distance
Acalypha hispida ; 200 mm polybag size; 900 mm height; 0.9 m c/c distance
Tabernaemontana ; 200 mm polybag size; 900 mm height; 0.9 m c/c distance
Chamaedorea elegans ; 300 mm polybag size; 900 mm height; 0.8 m c/c distance
Bambusa balcooa ; 200 mm polybag size; 900 mm height; 0.9 m c/c distance
Phyllostachys aurea - fishpole bamboo ; 200 mm polybag size; 900 mm height; 0.6 m c/c distance
Bambusa ventricosa ; 200 mm polybag size; 900 mm height; 0.6 m c/c distance
Rhapis excelsa ; 200 mm polybag size; 900 mm height; 0.6 m c/c distance
Dypsis lutescens ; 200 mm polybag size; 900 mm height; 0.6 m c/c distance
licuala grandis - ruffled palm ; 200 mm polybag size; 900 mm height; 0.9 m c/c distance
Tecoma stans ; 200 mm polybag size; 900 mm height; 0.9 m c/c distance
Duranta plumieri Syn. O. plumieri ; 200 mm polybag size; 900 mm height; 0.6 m c/c distance
Alocasia ; 300 mm polybag size; 900 mm height; 0.8 m c/c distance
Lawns Providing, planting and developing ground covers with the approved variety of plants including excavating the existing soil to a maximum depth of about 300 mm, removal of excavated earth to directed location, dressing the soil in proper slopes, filling excavated bed with approved soil mixture and manure, planting approved quality grass, including weeding out and removal of foreign matter, watering etc complete.
Cynodon dactylon
Stenotaphrum secundatum
Grasses Providing, planting and developing Grass bed with under noted varieties of grasses (both shade & sun loving), including excavating the soil to a depth of 450mm of required area as per grass species, removal of excavated earth to directed location, filling the excavated bed with approved soil mixture and manure, planting the approved variety grasses, providing strong stack etc. as per specification and as directed complete in all respect, including watering and nurturing the plants.
Saccharaum spontaneum ; 200 mm polybag size;900 mm height; 0.9 m c/c distance
Vetiver ; 200 mm polybag size;900 mm height; 0.6 m c/c distance
Cymbopogon flexuosus ; 200 mm polybag size;900 mm height; 0.6 m c/c distance
Typha latifolia ; 200 mm polybag size;900 mm height; 0.6 m c/c distance
Pennisetum setaceum white ; 200 mm polybag size;900 mm height; 0.6 m c/c distance
Pennisetum setaceum purple ; 200 mm polybag size;900 mm height; 0.6 m c/c distance
Cyperus alternifolious ; 200 mm polybag size;900 mm height; 0.6 m c/c distance
Asperagaceae family: Providing, planting and developing plants with under noted varieties of plants (both shade & sun loving), including excavating the soil to a depth of 450mm of required area as per plant species, removal of excavated earth to directed location, filling the excavated bed with approved soil mixture and manure, planting the approved variety plants, providing strong stack etc. as per specification and as directed complete in all respect, including watering and nurturing the plants.
Agave angustifolia : 200 mm polybag size; 900 mm height; distance as per dwg
Yucca filamentosa : 200 mm polybag size; 900 mm height;distance as per dwg
Furcraea foetida : 200 mm polybag size; 900 mm height; distance as per dwg
Aloevera : 200 mm polybag size; 900 mm height; 0.6 m c/c distance
Dracaena trifasciata - Snake plant : 200 mm polybag size; 900 mm height; 0.6 m c/c distance
Dracaena marginata - Coloroma : 200 mm polybag size; 900 mm height; 0.6 m c/c distance
Vegetable patch Providing, planting and developing plants with under noted varieties of plants (both shade & sun loving), including excavating the soil to a depth of 450mm of required area as per plant species, removal of excavated earth to directed location, filling the excavated bed with approved soil mixture and manure, planting the approved variety plants, providing strong stack etc. as per specification and as directed complete in all respect, including watering and nurturing the plants.
Bottle gourd,Cauliflower, Spinach, Cabbage, Coriander, Fenugreek, Mint, Potatoes, Carrots, Chilli, brinjal, Purple Yam
Aquatic Plants Providing, planting and developing plants with under noted varieties of aquatic plants, including Potting the plants in pots of 350 mm dia and 400 mm depth with appropriate clay soil mixture as per plant species, planting the approved variety plants, providing strong stack etc. as per specification and as directed complete in all respect, including manuring and nurturing the plants.
Pistia stratiotes - Water cabbage : 100 mm polybag size; 450 mm height; as per dwgs
Nymphaea spp. - Water Lily : 150 mm polybag size; 450 mm height; as per dwgs
Nelumbo lutea - Yellow Lotus : 150 mm polybag size; 450 mm height; as per dwgs
Thalia dealbata - Thalia : 150 mm polybag size; 450 mm height; as per dwgs
Eichhornia crassipes - Water Hyacinth : 100 mm polybag size; 450 mm height; as per dwgs
Creepers Providing, planting and developing plants with under noted varieties of plants (both shade & sun loving), including excavating the soil to a depth of 300mm of required area as per plant species, removal of excavated earth to directed location, filling the excavated bed with approved soil mixture and manure, planting the approved variety plants, providing strong stack etc. as per specification and as directed complete in all respect, including watering and nurturing the plants.
Thunbergia grandiflora: 100 mm polybag size; 450 mm height; as per dwgs
Jacquemontia: 100 mm polybag size; 450 mm height; as per dwgs
Allamanda cathartica: 100 mm polybag size; 450 mm height; as per dwgs
Trachelospermum jasminoides: 100 mm polybag size; 450 mm height; as per dwgs
Allamanda blanchetii: 100 mm polybag size; 450 mm height; as per dwgs
Epipremnum aureum -Money plant: 100 mm polybag size; 450 mm height; as per dwgs
Total of PART I-R : Softscape Work
Description of Work / Item(s)
Amount
ABSTRACT FOR PART - II : PUBLIC HEALTH ENGINEERING WORK
PART II-A : SANITARYWARES & CP APPURTENANCES.
PART II-B : INTERNAL WATER SUPPLY SYSTEM
PART II-C : INTERNAL DRAINAGE SYSTEM
PART II-D : EXTERNAL WATER SUPPLY
PART II-E : EXTERNAL SEWARAGE SYSTEM
PART II-F : RAIN WATER HARVESTING
PART II-G : CONTINGENT MECHANICAL WORK TO PH WORKS
PART II-H : LANDSCAPE IRRIGATION SYSTEM WORK
PART II-I : SWIMMING POOL WORKS
Description of Work / Item(s)
Amount
PART - II : PUBLIC HEALTH ENGINEERING WORK
Part II-A : Sanitarywares & C.P Appurtenances. Note:- 1) All sanitaryware shall be provided from same brand 2) All CP fittings / Fixtures from same brand shall be provided.
Providing and fixing in position following Vitreous China Wall Hung type Wash down pattern water Closet consisting following items of work:- i) Providing Vitreous China wall hung type wash down pattern Water Closet ( EWC ) conforming to IS 2556 (part XVI) with integral "P" trap outlet with water seal not less than 50 mm with vent and necessary C.I. brackets supports. ii) Providing thermosetting or thermoplastic Seat & cover conforming to IS 2548, fixing seat & cover for water closet as per manufacturer's specification including the cost of corrosion resistant hinges, bolts, nuts, non ferrous or S.S washer etc. all complete. iii) Fixing the Water closet in position, jointing the trap, water closet and CI/UPVC pipe by Epoxy grout or Rubber seal as per pipe manufacturer. iv) Cutting hole, making grove or chases in the wall, floors, slabs etc., reinstating to it's original condition after completion of work, painting all metallic parts with two coats of flat oil paint of approved make & shade over a coat of primer, finishing the gaps with white / matching colour cement etc. all complete. v) Testing the system to the full satisfaction of the Engineer-in-Charge.
Vitreous China European Water Closet of Starwhite/snow white/bright colour with P trap of "Hindware" Cat. No. 20069/20097 Lara model with slow falling seat cover or Cera cat. No. S1041111 Cruse model with slow falling seat cover or Parryware Cat. No. C0264 Cardiff model with slow falling seat cover.
Providing Flushing arrangement to water closet including providing and fixing manually operated PVC low level concealed flushing cistern consisting following items of work :- Providing 3.0 / 6.0 ltrs. capacity white colour PVC low level, leak proof, water saving, dual flush, durable concealed Flushing Cistern with all inside syphonic fittings & flush plate, duly assembled conforming to IS:7231 of following make, fixing the cistern in position using CP brass screws, rawl plugs, brackets etc. as per the manufacturer's recommendation, making outlet connection with EWC including the cost of supplying & fixing PVC Flush pipe etc. all complete. Cutting hole, making chases in the walls, floors, slabs etc and reinstating the surface to the original condition, painting all metallic parts with two coats of flat oil paint of approved make and shade over a coat of primer, finishing the gaps with white / matching cement etc. all complete. Testing the entire system to the full satisfaction of the E.I.C.
Providing and fixing PVC low level Dual Flush Concealed Cistern, as per Hindware Cat. No. 525063 "NEO full frame & drain set - QF" model including "Loop Neo Chrome" flush plateor Cera cat. No. B1110111+B1190104+B1190105+ B1190106+B1190107 "CHEVRON" model including "B1120101" flush plate, PVC Flush pipe etc. all complete or approved equivalent Make
Providing and fixing urinal of approved make consisting following items of work: i) Providing urinal of approved make, and placing it in position as shown in the drawing or as per manufactures specification or as directed including finishing the joints with white / matching colour cement all complete. ii) Providing various CP fittings such as Waste Coupling , Bottle Trap including provision and fixing 32 mm minimum 10kg class PVC pipe conforming to IS:4985 (and fittings conforming to IS:7834) Waste Pipe from Bottle trap to adaptor / Nahani trap / Floor Trap. ( Bottle trap & waste coupling will be paid separately under the relevant item.) iii) Fixing the urinal in position, including providing M.S. Brackets & Screws for the urinal as per Manufactures specification or as directed by Engineer-in Charge. iv) Cutting hole, making grove or chases in the wall, floors, slabs etc., reinstating to it's original condition after completion of work, painting all metallic parts with two coats of flat oil paint of approved make & shade over a coat of primer, finishing the gaps etc. all complete as directed by Engineer-in Charge. v) Testing the system to the full satisfaction of the Engineer in Charge.
Vitreous china urinal of Starwhite/snow white/bright colour as per Hindware Cat. No. 60010 "Dyna" model or Cera cat. No. S4020113 "Civic" model or Parryware Cat. No.C0580+C8123 "Whiz" model with connector etc.all complete or approved equivalent Make
Providing Flushing arrangement to Urinal including providing and fixing Sensors / manually operated flush valves consisting following items of work:- i) Providing and fixing flush valve/Sensor in position as per the manufacturer's recommendation, making water inlet connections all complete. ii) Providing & laying 15 mm dia. CPVC (SDR11) / 15 mm n.b GI class 'C' Flush Pipe / CP brass inlet connection from Flush Valve / Sensor to Urinal, concealed/exposed in the wall as directed making connection with Urinal spreader and flush valve / Sensor including the cost of heavy quality CP brass Spreader combatible to the Urinal, necessary fittings, fixtures, jointing materials etc. all complete. iii) Cutting hole, making chases in the wall, floors, slabs etc. and reinstating the surface to the original condition, painting all metallic parts with two coats of flat oil paint of approved make and shade over a coat of primer, finishing the gaps with white/ matching cement etc. all complete. iv) Testing the entire system to the full satisfaction of the E.I.C.
Flushing arrangement with flush valve of Jaquar 'Sensor' make Cat No.SNR-STL-51087, Flush bend, cutting hole, testing etc.for Urinal or approved equivalent Make or approved equivalent Make
Providing and fixing first Quality Vitreous China hand wash Basin Consisting following items of work. - i) Providing Wash Basin and placing it in position as shown in the drawing or as per manufactures specification or as directed including finishing the joints with white / matching colour cement all complete. ii) Fixing various CP fittings such as Waste Coupling, Bottle Trap including fixing 32 mm minimum 10kg class PVC pipe conforming to IS:4985 (and fittings conforming to IS:7834). Placing and fixing Waste Pipe from Bottle trap to adaptor / Nahani trap / Floor Trap. iii) Fixing the Wash Basin in position, including providing M.S./C.I. Brackets & Screws for the basin. iv) Cutting hole, making grove or chases in the wall, floors, slabs etc., reinstating to it's original condition after completion of work, painting, finishing the gaps etc. all complete as directed by Engineer-in Charge. v) Fixing Vitreous China under / over the counter / semi recessed type Wash Basin of following model and make conforming to IS 2556 and placing it in position with the granite platform as shown in the drawing or as directed including finishing the joints with white cement all complete. vi) Testing the system to the full satisfaction of the Engineer in Charge
iv) Cutting hole, making grove or chases in the wall, floors, slabs etc., reinstating to it's original condition after completion of work, painting all metallic parts with two coats of flat oil paint of approved make & shade over a coat of primer, finishing the gaps etc. all complete as directed by Engineer-in Charge. v) Fixing Vitreous China under / over the counter / semi recessed / over table type Wash Basin of following model and make conforming to IS:2556 and placing it in position with the granite platform as shown in the drawing or as directed including finishing the joints with white cement all complete. vi) Testing the system to the full satisfaction of the Engineer in Charge
Vitreous China Wash Hand Basin of StarWhite colour of Hindware Cat. No. 10104 "Fabio" model or Cera Cat. No. S2021167 "Cleen" model or Parryware Cat. No. C8845 "Clara" model, table tap model or approved equivalent Make
Providing braided hose with nuts, nipples etc. for Watersupply Inlet connection of following make for washbasin, flush tank, kitchen sink etc with brass check nutson both ends and fixing it in position as directedincluding the cost of jointing materials and testing for leak proof joints all complete.
450mm Long Braided Hose with Two 15mm Nuts & Rubber Washers (Suitable for Geysers) of Jaquar cat. No. ALD-805B or approved equivalent make.
Providing & fixing in position best quality bevelled edge plate Glass Mirror with PVC frame of following size with 6 mm thick marine ply wood (confirming to IS:710), fixed with required numbers of CP brass cupscrews and caps, washers etc. including drilling holes, providing & fixing rawl plug in RCC/ brick wall, woodenpacking behind the mirror if necessary, reinstating the damages to its original condition etc. all complete as directed by EIC.
Mirror with all accessories for fixing on wall of Jaquar 'Kubix Prime' Cat.No.AKP-35795, Swivel Mirror 630 X 445mm, Rectangular Shape or approved equivalent make
Providing and fixing in position following Vitreous China Pedastal type Wash down pattern water Closet, Wash Basin and supporting rails for Paraplegic consisting following items of work:- i) Providing Vitreous China padastal type wash down pattern Water Closet (EWC) conforming to IS:2556 (Part II) with integral "P" trap outlet with water seal not less than 50mm with vent and necessary supports. ii) Providing thermosetting or thermoplastic Seat & cover conforming to IS:2548, fixing seat & cover for water closet as per manufacturer's specification including the cost of corrosion resistant hinges, bolts, nuts, non ferrous or S.S. washer etc. all complete. iii) Fixing the Water closet in position, jointing the trap, water closet and UPVC pipe by Epoxy grout or Rubber seal as per pipe manufacturer. iv) Providing Wash Basin and placing it in position as shown in the drawing or as per manufactures specification or as directed including finishing the joints with white / matching colour cement all complete.
v) Providing various CP fittings such as Waste Coupling of Jaquar Cat No. 705/709, Bottle Trap of Jaquar Cat. No. 769 including fixing 32/40/50 mm minimum 10kg class PVC pipe conforming to IS:4985 (and fittings conforming to IS:7834). Placing and fixing Waste Pipe from Bottle trap to adaptor / Nahani trap / Floor Trap. vi) Fixing the Wash Basin in position, including providing M.S./C.I. Brackets & Screws for the basin. vi) Fixing grab rails as per drawing or manufacturer's recomandations vii) Cutting hole, making grove or chases in the wall, floors, slabs etc., reinstating to it's original condition after completion of work, painting all metallic parts with two coats of flat oil paint of approved make & shade over a coat of primer, finishing the gaps with white / matching colour cement etc. all complete. viii) Testing the system to the full satisfaction of the Engineer-in-Charge.
Providing & fixing a Vitreous China European Water Closet Paraplegic set of Starwhite (Standard) colour with P trap of Hindware make Cat. No. 70002 Matrix Set-1 consisting of Wash Basin 65 x 35 with one pair mounting brackets, EWC & Cistern complete with fittings & seat cover, one no. hinged rail 76 cm and four nos of grab rails 60 cm.
Providing & fixing in position following approved quality water saving CP fittings / Fixtures of 15 mm nominal dia. with ISI mark / approved make of following type including providing & fixing specials, wall flanges and fixing to concealed / exposed pipe line with leak proof threaded joints using tephlon tapes, testing the joints hydraulically to a pressure of 10 kg./ sq.cm, rectifying the leaky joints. if any, including cleaning etc. complete all as per specification.
C.P. brass 2 Way Bib Cock with wall flange of Jaquar 'Florentine' Cat.No.FLR-5041N or approved equivalent make
C.P. brass 2 Way Bib Cock with wall flange of Jaquar 'Solo' Cat.No.SOL-6041 or approved equivalent make
C.P. brass Bib Cock with wall flange of Jaquar 'Florentine' Cat.No.FLR-5047N or approved equivalent make
C.P. brass Pillar Cock with wall flange of Jaquar 'Florentine' Cat.No.FLR-5011N or approved equivalent make
C.P. brass Angular Stop Cock with wall flange of Jaquar 'Florentine' Cat.No.FLR-5053N or approved equivalent make
C.P. brass Sink Cock with wall flange of Jaquar 'Florentine' Cat.No.FLR-5347SD/FLR-5357SD or approved equivalent make
C.P. brass Single lever Diverter consealed Body of Jaquar Cat. No. ALD-079N with Exposed Part kit of Jaquar 'Florentine' Cat. No. FLR-5079NK and Spout with wall flange of Jaquar Cat. No. SPJ-5429S or approved equivalent
C.P. brass Shower of Jaquar Cat.No.OHS-1989 or approved equivalent make
C.P. brass Shower Arm with wall flange of Jaquar Cat.No.SHA-477 or approved equivalent make
C.P. Health Faucet with 8 mm dia 1.5 m long flexible tube & Wall Hook of Jaquar Brand 'Allied' Cat. No. ALD-587 or approved equivalent make
C.P. brass Waste Coupling 32mm size of Jaquar Cat.No.ALD-709/709L130/705/705L130 or approved equivalent make
C.P. brass Bottle Trap 32mm Size including Wall Connection Pipes & Wall Flange of Jaquar Cat.No. ALD-769L250x190 / 769L300x190 or approved equivalent make
Providing and fixing the following C.P. Brass Bathroom / toilet accessories of following make and fixing on the wall using C.P. brass screws, rawl plugs etc. as per manufacturer's requirement all complete at the locations shown and as directed by the Engineer Incharge.
C.P. Brass Toilet paper Roll Holder of Jaquar Brand 'Continental' Cat. No. ACN-1151N or approved equivalent make
C.P. brass single Towel Rail 600mm long of Jaquar Brand 'Continental' Cat. No. ACN-1111SM or approved equivalent make
C.P. brass Towel Ring Square with Flange of Jaquar Brand 'Continental' Cat. No. ACN-1121N or approved equivalent make
C.P. brass Double Coat Hook of Jaquar Brand 'Continental' Cat. No. ACN-1161N or approved equivalent make
C.P. brass Soap Dispenser with Glass Bottle of Jaquar Brand 'Continental' Cat. No. ACN-1135N or approved equivalent make
C.P. brass Soap Dish Holder with Glass Dish of Jaquar Brand 'Continental' Cat. No. ACN-1131N or approved equivalent make
Supplying Stainless steel Sink of following size with or without Drain board, approved make, moulded out of 19 SWG (1mm) stainless steel sheet of grade AISI304 (18/8) with waste coupling conforming to IS:13983,placing and fixing the Sink in position to correct line and level with basket type choke-stop strainer (wastecoupling), Check nuts etc. including the cost of jointing materials, finishing the edges with white / matching colour cement as per manufacturer's recommendation all complete as per specification and as directed by EIC.
Stainless steel Sink of Nirali brand 'Grace Plain' Medium without Drain board and with 'Satin' finish of overall size 510 x 432 mm (Bowl size 450 x 375 x 200 mm) or approved equivalent make.
TOTAL OF Part II-A : Sanitarywares & C.P Appurtenances.
Part-II- B : Internal Water Supply System
Supplying & fixing on Exposed surfaces the following sizes uv-stabilized Chlorinated Poly Vinyl Chloride (CPVC) pipes & Fittings of specified class having thermal stability for both hot & cold water supply consisting following items of work:- i) Supplying CPVC pipes and all required CPVC plain and brass threaded fittings, SDR - 11 having thermal stability for hot & cold water supply of approved make conforming to IS:15778 with ISI mark for CPVC pipe having nominal size up to 50 mm and conforming to ASTM F 441 (IPS SERIES) Schedule 40/80 for CPVC pipe having nominal size 65 mm (2½”) and above. ii) Supplying & providing providing CPVC/GI flanges, any other required specials and other jointing materials for connecting the CPVC pipe lines with spool pieces of water tank and for connecting the CPVC pipe lines with any fittings & fixtures etc., of the water supply line iii) Laying and fixing the pipe and specials on exposed surfaces/ underground, to correct line, level and plumb for water supply line, using metal straps (On wall surfaces) at 1.00 mtr. interval or as directed by the EIC. iv) Jointing the pipes and Specials using Solvent cement conforming to IS:15225 & Teflon tape ( For threaded joins ) of approved makes including cutting the pipe to required size, preparation of surfaces, necessary tools etc. all complete.
v) Cutting or making hole or chases in RCC or brick work structure such as wall, column, beam, slab, chajja, dado etc. for passing the pipe line and reinstating all the damage to its original condition. vi) Testing the pipe line as per relevant code to a hydraulic pressure of 10 Kg / Sq.cm to assess leakages if any, rectifying the defect, retesting etc till water tightness of pipe line is ensured. vii) CPVC pipes and fittings/ specials shall be of same brand. NOTE: 1) The rate shall also include for cPVC pipe & specials required for making connections with the existing GI/ CPVC/PP-R/ UPVC/HDPE pipe line laid by other agency. 2) All threaded joints shall be made with brass threaded fittings only. 3) Exposed pipe fixing arrangement include providing & fixing slotted G.I. section & U clamps bolts arrangement for grouping of pipe. Sloted section thickness should not be less than 2mm.
20 mm(¾") n.size (SDR-11 as per IS:15778)
25 mm (1") n.size (SDR-11 as per IS:15778)
32 mm (1¼") n.size (SDR-11 as per IS:15778)
40 mm (1½") n.size (SDR-11 as per IS:15778)
50 mm (2") n.size (SDR-11 as per IS:15778)
65 mm (2½") n.size (Shedule 80)
80 mm (3") n.size (Shedule 80)
100 mm (4") n.size (Shedule 80)
Supplying, fixing & concealing on wall / beams / columns etc. the following sizes UV- stabilised Chlorinated PolyVinyl Chloride (CPVC) Pipes & (male / female) brass threaded fittings Fittings of specified class having thermal suitable for both hot & cold water supply & suitable for fixing various fittings & fixtures such as taps, jet sray, wall mixture, concealed stop cock, flush valves etc., consisting following items of work :- i) Supplying CPVC pipes and all required CPVC plain/ and brass threaded fittings, SDR - 11 having thermal stability for hot & cold water supply of approved make conforming to IS:15778 with ISI mark for CPVC pipe having nominal size up to 50 mm and conforming to ASTM F 441 (IPS SERIES) Schedule 40 for CPVC pipe having nominal size 65 mm (2½”) and above. ii) Laying and concealing the pipe and specials for water supply by cutting/ making 75 mm X 75 mm groove on the wall, fixing the pipe using metal straps wherever required and filling the groove with cement mortar mixed with water proofing compound, after laying and testing the pipe line including making leak proof joints using cement solvent/ Teflon tape ( For threaded fittings) of approved make, cutting the pipe to required length, preparation of surface, necessary tools etc. all complete.
iii) Cutting or making hole or chases in RCC or brick work structure such as wall, column, beam, slab, chajja, dado etc. for passing the pipe line and reinstating all the damage to its original condition. iv) Testing the pipe line as per relevant code to a hydraulic pressure of 10 Kg / Sq.cm to assess leakages if any, rectifying the defect, retesting etc till water tightness of pipe line is ensured. v) CPVC pipes and fittings/ specials shall be of same brand. NOTE:- 1) The rate shall also include for cPVC pipe & specials required for making connections with the existing GI/ CPVC/PP-R/ UPVC/HDPE pipe line laid by other agency. 2) All threaded joints shall be made with brass threaded fittings only.
20 mm(¾") n.size (SDR-11 as per IS:15778)
25 mm (1") n.size (SDR-11 as per IS:15778)
32 mm (1¼") n.size (SDR-11 as per IS:15778)
40 mm (1½") n.size (SDR-11 as per IS:15778)
50 mm (2") n.size (SDR-11 as per IS:15778)
Providing class-2 following diameter Gate Valve (full way) of brass or gun metal with Cast iron wheel conforming to IS:778, fixing to pipe line including the cost of white zinc, spun yarn etc., testing for leak proof joints at a hydraulic pressure of 10 Kg / Sq.cm, rectifying the leakages if any, all complete as per specification and as directed. Note: 1) Wherever required union joint shall be provided in pipe to facilitate removal of valve. 2) Threaded fittings of CPVC/UPVC shall be of Brass Threaded only.
20 mm size (PN 1.6)
25 mm size (PN 1.6)
32 mm size (PN 1.6)
40 mm size (PN 1.6)
50 mm size (PN 1.6)
65 mm size (PN 1.6)
80 mm size (PN 1.6)
100 mm size (PN 1.6)
Providing following size Cast Iron / Spiroidal Iron Singal Air valve of PN 1.6 of approved quality and make conforming to IS:14845 with ISI mark & Copper/Brass isolation Gate valve of PN as per air valve of approved quality and make conforming to IS:778/IS:13114, Tapers and specials etc. including making necessary screwed / flanged joints by providing all jointing materials testing the joints and valves hydraulically to a pressure & duration as specified along with the pipeline all as per the specifications and as directed by the E.I.C.
25 mm size (PN 1.6)
Providing and fixing Nitrile Rubber Insulation with UV protected CLASS-O ALUPET FOIL over insulation pipes in wall chase and filling the wall chase as per manufature's specifications for hot water insulation. (INTERNAL WORK : INSIDE THE WALL/ COVERED INSTALLATION/ SUNK SLAB) (EXPOSED WORK : VERTICAL PIPE / TERRACE ROUTING PIPE)
20 mm dia. (9MM Thick)
25 mm dia. (13MM Thick)
32 mm dia. (13MM Thick)
40 mm dia. (13MM Thick)
50 mm dia. (13MM Thick)
65 mm dia. (13MM Thick)
Providing Gun metal Pressure Reducing Valves as per IS:9739 of approved make with ISI mark and fixing the same on the Down take pipe line using white Zinc, hemp yarn etc. including testing the system for leakproofness all complete as shown & directed by EIC. Note: 1) Wherever required union joint shall be provided in pipe to facilitate removal of valve. 2) Threaded fittings of CPVC/UPVC shall be of Brass Threaded only.
40 mm (1½") n.size
50 mm (2") n.size
Supplying & fixing following size C.P. brass Coupling with approved quality C.P. brass Mosquito proof jalli including providing CPVC/UPVC/GI connector, bend and any other CPVC/ GI specials, if required for fixing the coupling, jointing materials such as tefflon tapes, spun yarn, white zinc, fixing the same to GI/CPVC/UPVC pipes etc. complete as specified & directed for overflow / vent pipe of water tank.
50 mm size
Supplying & fixing following Stainless Steel (grade 316) spool pieces of required diameter having flange on one/ both end with flange holes in flanges for fixing with nut & bolts (OR) with screwed ends on both/ one end as per site requirement and as directed by the Engineer in charge, having 450 mm/ required length, providing 3D x 3D (where D is the outer diameter of pipe) and 4 mm thick stainless steel puddle plate (minimum size 150mmx 150mm) welded to it including cutting the plate to required shape and fixing in the reinforcement at the center of RCC wall/ slab at required level, height etc including cutting the form work provided for casting concrete etc., complete all as per specifications and as directed by Engineer-in-Charge. Note:- Actual weight of spool piece only will be measured for payment and no payment will be made for any wastages.
40 mm to 450 mm dia
Providing class-2 following diameter Check Valve (full way) of brass or gun metal conforming to IS:778, fixing to pipe line including the cost of white zinc, spun yarn etc., testing for leak proof joints at a hydraulic pressure of 10 Kg / Sq.cm, rectifying the leakages if any, all complete as per specification and as directed. Note: 1) Wherever required union joint shall be provided in pipe to facilitate removal of valve. 2) Threaded fittings of CPVC/UPVC shall be of Brass Threaded only.
20 mm size (PN 1.6)
25 mm size (PN 1.6)
40 mm size (PN 1.6)
65 mm size (PN 1.6)
Providing, instaling, fixing, connecting, testing 75 micron Super Flow Plus filter, of M/s. Jain Irrigation Systems Ltd., of following Model Nos, fitted with pressure gauge, water drain and emptying plug. etc all as per specifications, Drawings and as directed by EIC. NOTE: Threaded fittings of CPVC/UPVC shall be of Brass Threaded only.
DJPSFP25SW, Max. working pressure = 10 kg/cm², Flow rate = 25 m³/hr, Inlet/Outlet Connection = 2"
DJPSFP40SW, Max. working pressure = 10 kg/cm², Flow rate = 40 m³/hr, Inlet/Outlet Connection = 2½"
DJPSFP50SW, Max. working pressure = 10 kg/cm², Flow rate = 50 m³/hr, Inlet/Outlet Connection = 3"
Providing, instaling, fixing, connecting, testing 75 micron Super-Clean 'Y' Deluxe filter, of M/s. Jain Irrigation Systems Ltd., of following Model Nos, fitted with pressure gauge, water drain and emptying plug. etc all as per specifications, Drawings and as directed by EIC. NOTE: Item Includes Flange jointing with required new flanges and hardware.
DSCYM060 with flanges, Max. working pressure = 10 kg/cm², Flow rate = 60 m³/hr, Inlet/Outlet Connection = 4"
DSCYM120 with flanges, Max. working pressure = 10 kg/cm², Flow rate = 120 m³/hr, Inlet/Outlet Connection = 6"
Providing GRP / FRP composite Mosquito proof hinged cover with frame for Overhead Water Tank manhole (having loading capacity not less than 300 Kg) of approved manufacturers, having suitable locking arrangement for Manhole opening of water tank, fixing the cover by providing corrosion resistant studs, nuts, built-in hold fasts etc. by chasing or cutting holes and grouting with cement mortar 1:1 by adding approved water proofing compound @ 2% by weight of cement, all complete as per specification and as directed by EIC. Note: OHT manhole cover shall be approved by local autority like BMC
600 mm dia.
Providing, hoisting and installing at required elevation Rotational moulded polyethylene cylindrical vertical storage tanks with BIS mark confirming to IS:12701 of Sintex make or approved equivalent make of below said capacity with suitable municipal approved mosquto proof cover at top with proper locking arrangement including the cost of hoisting the tank carefully to the required elevation without causing any damage, labour charges for making required number of holes for inlet, required number of outlets to each tank, required number of vent pipe outlets to each tank and overflow outlets in the tank without causing any damage to tank, including cost of providing all required CPVC/GI/UPVC/PPR specials, fixtures, fittings, tank connectors, adopters, union etc., providing and fixing required numbers of flexible PVC pipe / polymer reinforced thermoplastic hoses suitable for Suction / delivery lines of agricultural pumps confirming to IS:15265 of Kissan Brand or approved equivant make Heavy Grade suction / delivery hose to inlets & outlets having dia suitable for connecting to 50 mm nominal size CPVC/GI/UPVC water supply line, having length (flexible pipe) of about 0.75 Metre/
Tank of 500 liter capacity of M/s. Sintex or approved equivalent.
TOTAL of Part-II- B : Internal Water Supply System
Part-II-C : Internal Drainage System
Supplying and fixing following size uPVC UV-Stabilised soil / waste quality pipes and fittings ( SWR ) for soil, waste, vent, anti syphonage, HVAC waste pipe and rain water pipe lines consisting following items of work:- i) Providing and fixing uPVC UV-Stabilised Soil/ waste pipe as per IS:13592 and IS:14735 Type-B laid in floor & on Exposed faces of wall of approved make ii) Fixing the pipeline vertically by Metal clamps with rubber seal of approved make iii) Fixing the pipeline Horizontaly with specified slope below the ceiling by Metal clamps with rubber seal and GI hanger rods not less than 5mm dia at specified spacing, including all required hardware. iv) Providing and fixing uPVC cowl at the top of soil, waste water & vent pipe line. v) Providing and fixing uPVC P/S trap on line as per requirement for soil,waste water pipeline. vi) Laying the pipe below floor / ground to the slope and gradient equal to (or) steeper than 1 in 50, making leak proof connections of soil /waste pipe line from the shaft with inspection chamber / Manhole / Gully trap Chamber including the cost of filling around the holes of inspection chamber / Manhole / Gully trap with cement mortar 1:1 mixed with water proofing compound
vii) Jointing the pipe / fittings with Solvent Cement & Rubber ring gasket with making holes in walls / floor grooving and redoing the same and brick support etc. Carrying out water-tightness test for the pipes laid as per codal provisions. Providing Ring Joint pipes at verticals and solvent cement jointed pipes at concealed locations. viii) Cutting the pipe to the required length including providing short pieces, necessary connectors, fittings & specials with & without door, assorted fittings such as plugs, tees, couplers, reducers, cross tees, reducing tees, elbows, bends, single & double Y, vent cowl, gaskets, offsets etc. including providing necessary clean outs, cleaning pipe, extension pipe if any for clean outs, door bend, door elbow, door Y, socket plug, etc wherever required for accessing every segment of soil and waste pipes to enable removal of any Chock up after installation. ix) Providing necessary specials for connecting UPVC SWR (IS:13592/ IS:14735) pipe with UPVC (IS:4985) pipe etc x) Dewatering the pit/ trenches if necessary till completion of work
xi) Testing the pipe line for any leakages, rectifying the leakages if any, retesting etc., till water tightness of the pipe line is ensured. xii) Exposed pipe fixing arrangement include slotted G.I. section and U clamps. Note: Earthwork excavation for trenches shall be paid under relevant items For Soil & waste, Vent and Rain water pipe lines
75 mm dia.
110 mm dia.
160 mm dia.
Supplying, fixing & concealing on walls/ beams/ floors columns etc. the following sizes uPVC Pipes & Fittings of specified class consisting following items of work:- i) Supplying uPVC pipes conforming to IS:4985 and uPVC moulded plain / threaded fittings conforming to IS:7834 for waste water pipe line of approved make with ISI mark / equivalent approvals as per relevant standards, providing necessary specials for connecting UPVC (IS:4985) pipe with UPVC SWR (IS:13592) pipe etc. ii) Laying and concealing the pipe and specials for waste water by cutting/ making 75 mm X 75 mm groove on the wall, fixing the pipe using metal straps wherever required and filling the groove with cement mortar 1:3 mixed with water proofing compound, after laying and testing the pipe line including making leak proof joints using cement solvent/ Teflon tape ( Forthreaded fittings) of approved make, cutting the pipe to required length, preparation of surface, necessary tools etc. all complete.
iii) Cutting or making hole or chases in RCC or brick work structure such as wall, column, beam, slab, chajja, dado etc. for passing the pipe line and reinstating all the damage to its original condition (No Chases in RCC wall, column, beam, slab, chajja,etc shall be made with out getting the permission from Engineer In charge & structural design Enginner) iv) Concealing the pipes in wall, Laying the pipe below floor/ ground to the slope and gradient equal to (or) steeper than 1 in 50 v) Testing the pipe line for any leakages, rectifying the leakages if any, retesting etc., till water tightness of the pipe line is ensured. For Urinal/ wash basin/ Anti syphonic/ Sink waste. (10kg Pressure)
Providing & fixing uPVC Floor P-Trap of following size having not less than 55mm effective water seal, fixing the trap in position and connecting with waste water pipe by cement solvent/ as per manufacturer's recommandation, embedding the trap in cement concrete 1:2:4 to correct level and gradient, providing and fixing 150 x 150 mm size top tile with central strainer & flat cover/ flush strainer, closing the side inletes with plugs if required etc. complete all as per specification and as directed by the Engineer in charge.
Providing and fixing stainless steel (SS304) Perforated grating 'of 18 gauge thick, with 'circular perforation including Cockroach trap of 'approved pattern over CI/PVC 'traps. The grating shall be of size 153mm x 153mm or circular of 100mm dia '(as directed) and shall 'be set in cement, sand mortar 1:3 etc. complete. (Euronics/ Chilly Makes) MAKE: CHILLY MODEL : CCT-SSGFC-153 or approved equivalent Make
Providing and fixing stainless steel (SS304) tile insert grating 'of 18 gauge thick, with 'circular perforation including Cockroach trap of 'approved pattern over CI/PVC 'traps. The grating shall be of size 153mm x 153mm or circular of 100mm dia '(as directed) and shall 'be set in cement, sand mortar 1:3 etc. complete. (Euronics/ Chilly Makes) MAKE: CHILLY MODEL : CCTL-SMR-152 or approved equivalent Make
Providing and fixing Height Riser of 110 x 75 x 50 size of approved make. Complete all as per specification and as directed by the Engineer in charge.
Providing & fixing uPVC Floor nahni trap of following size having not less than 55mm effective water seal, fixing the trap in position and connecting with waste water pipe by cement solvent/ as per manufacturer's recommandation, embedding the trap in cement concrete 1:2:4 to correct level and gradient, providing and fixing 150 x 150 mm size top tile with central strainer & flat cover/ flush strainer, closing the side inletes with plugs if required etc. complete all as per specification and as directed by the Engineer in charge.
Providing and fixing HDPE sheet flashing fabricated by welding HDPE flexible sheet with 160 mm dia HDPE pipe about 400mm long for PVC rain water pipes, fixing the same on RCC/cement concrete surface using approved synthetic glue, covering the HDPE sheet wateright with cement mortar 1:2 mixed with water proofing compound and forming the proper shape and grade and finishing with inlet mouth of rain water pipe, cutting RCC slab or wall if required, including the cost of bitumen, cement mortar etc. complete all as per specification and as directed by the Engineer-in-charge. NOTE: HDPE sheet flashing shall be sticked watertight over RCC / Cement Concrete surface by using approved synthetic glue as per manufacturers recommendation and as directed by the Engineer incharge. After fixing HDPE sheet flashing over RCC/ Cement concrete surface, the top potion of HDPE sheet flashing shall be spread with approved synthetic glue, fine (0.5 mm size) sand shall be sprinkled over it immeadiately, allowed to be dried and after drying it is to be covered watertight with cement mortar1:2 mixed with waterproofing compound @ 2% by weight of cement as per required shape and form. Item includes providing uPVC reducer for connecting to 110 mm dia pipe.
450 x 450 mm size HDPE sheet Flashing fabricated from 8 mm thick HDPE sheet and PN 6 grade 160mm dia HDPE pipe including 160 x 110 dia reducer.
Providing and fixing Stainless steel Dome mesh fabricated by welding from 2mm dia 304 grade stainless steel wire for PVC rain water pipes (sheet flashings), with 5mm x 10mm L base ring of 0.5mm thickness 304 grade Stainless steel. L ring to be embedded in waterproofing & dome to be placed on it, including the cost of fixing material etc. all complete as specified and as directed by the E.I.C.
Half Spherical Dome having opening 5 to 10 mm of 160 mm ID
TOTAL Part-II-C : Internal Drainage System
Part-II-D: External Water Supply System
Supplying and laying below the ground or floor, the following diameter uv-stabilized Chlorinated Poly Vinyl Chloride (C-PVC) pipe line of specified class, consisting the following items of work:- i) Supplying CPVC pipes and all required CPVC plain / brass threaded fittings, SDR - 11 having thermal stability for hot & cold water supply of approved make conforming to IS:15778 with ISI mark for CPVC pipe having nominal size up to 50 mm and conforming to ASTM F 441 (IPS SERIES) Schedule 40/80 for CPVC pipe having nominal size 65 mm (2½”) and above. ii) Laying and fixing the pipe and specials below the ground or floor to correct line, level and plumb for water supply line. iii) Making leak proof threaded/welded joints. including cutting the pipe, cleaning, marking, jointing, etc. and including the cost of jointing materials. iv) Cutting or making hole or chases in RCC or brick work structure such as wall, column, beam, slab, chajja, dado etc. for passing the pipe line and reinstating all the damage to its original condition. v) Providing and fixing C-PVC weldable / threaded fittings such as Union, Nipples, Bends, Elbows, Tees, Reducers, End caps, Couplers, Adaptors, Saddles, Plugs, Tank connectors, Expansion loops, Bypass bends, etc.vi) CPVC pipes and fittings shall be of same brand.
vii) Testing the pipe line as per relevant code to a hydraulic pressure of 10 Kg/Sq.cm to assess leakages if any, rectifying the defect, retesting etc till water tightness of pipe line is ensured NOTE:- 1) The rate shall also include for cPVC pipe & specials required for making connections with the existing GI / CPVC pipe line laid by other agency. 2) All threaded joints shall be made with brass threaded fittings Only. 3) Excavation and refilling shall be paid under relavent item.
20 mm(¾") n.size (SDR-11 as per IS:15778)
25 mm (1") n.size (SDR-11 as per IS:15778)
32 mm (1¼") n.size (SDR-11 as per IS:15778)
40 mm (1½") n.size (SDR-11 as per IS:15778)
50 mm (2") n.size (SDR-11 as per IS:15778)
65 mm (2½") n.size (Shedule 80)
80 mm (3") n.size (Shedule 80)
Providing & laying in trenches socket spigot centrifugally cast Ductile ( Spun ) iron pressure Pipes for water supply, Class K9 of approved make conforming to1S:8329, external zinc-bitumen coated and internal cement mortar lined with ISI mark, including lowering and keeping them in position to correct alignment and levels, laying (IS:12288), jointing with rubber gasket of SBR/EPDM as per IS 5382 and/or IS:12820 with ISI mark, cutting the pipe to the required length including the cost of wastage of pipes if any, cutting or making hole or chases in RCC or brick work structure such as wall, column, beam, slab, chajja, dado etc. for passing the pipe line and reinstating all the damage to its original condition. testing the pipes after making necessary joints to appropriate hydraulic pressure with minimum duration of testing for two hours with clean and potable water all as per specification and as directed by the Engineer incharge NOTE:- The pipe line shall be measured along the centre line duly deducting the outer to outer length of the specials. The above cost includes making 'push on' joints with Gasket.
100 mm dia.
Providing, laying and jointing following Ductile iron (fittings & specials), external Zinc bitumen coated & internal cement mortar lined with ISI mark, Mechanical, Flanged, and / or Push on' type Specials / Fittings, K12 Class conforming to IS 9523 of approved make such as Tees, Bends, Collars, reducers, tapers etc. of all sockets/ flanged/socket spigot etc. etc. with sealing Rubber Gasket of SBR conforming to IS 5382 and / or IS 12820 with ISI mark, cast / Ductile iron follower Gland, MS nuts & bolts coated or otherwise protected from rusting, suitable for D.I pressure pipes for water supply to correct alignment and levels including testing the specials to appropriate hydraulic pressure alongwith the pipe line with clean and potable water, as per specifications and directed by EIC. NOTE: Fittings shall be of specified type only. The above cost includes making 'push on' / Mechanical joints with Gasket, bolts, Nuts etc. and making flanged joints without new flanges.
Mechanical Joint Type Fittings / Flanged Joint Fittings / Push On Joint Type Fittings
Providing & fixing following dia. Flanged type Cast Iron / Spiroidal Iron Sluice Valve of PN 1.6 having stainless steel non-rising spindle with hand wheel conforming to IS:14846 (latest revision) with ISI mark, approved make, making necessary flanged joints with rubber gasket of EPDM/SBR as per IS:5382 and / or IS:12820 with ISI mark of approved make, providing all jointing materials & testing the joints and valves hydraulically to a pressure & duration as specified along with the pipeline all as per the specifications and as directed.
50 mm size (PN 1.6)
65 mm size (PN 1.6)
80 mm size (PN 1.6)
100 mm size (PN 1.6)
Construction of fly ash / AAC /kiln burnt clay brick masonry valve chambers of following dimensions for depth as mentioned below comprising of 230 mm thick brick masonry in cement mortar 1:4 over a bed of 150 mm thick cement concrete of grade 1:2:4 for foundation with 150 mm offset allround, including racking out joints & plastering in cement mortar 1:3, 20 mm thick both on internal and external surfaces, internal surfaces finished smooth with a floating coat of neat cement, Fixing (FRP/GRP coposite / DI / CI / SFRC / RCC / MS) Frame and cover of approved make all as per specifications and directions of the E.I.C. including dewatering the pit, if required till completion of the work all complete. Note: steps / foot rests / rungs will be mesured and paid under relavant item.
Chamber measuring 0.9 mtr. X 0.9 mtr. for an initial depth of 600 mm (Clear internal dimension)
Extra over above item no. 38.1 for additional depth of valve chamber beyond initial depth of 0.60 mtr. without steps / foot rests / rungs etc. all complete.
Making connection from Municipal water supply line to make new water supply connection including breaking them in a systematic way with suitable excavation, dewatering, dismantling of the RCC or masonry wall or pipe line, passing the plumbing storm water line in the existing structure either through masonry or RCC and providing suitable "Y" tee to the connect to existing pipe line, Reconstructions of dismantled existing structure according to the original one to bring to the working conditions testing etc. work to be done in the presence of municipal eng. including Liasoning cost. complete as per standard as directed by Engineer-in-charge to complete the job. (Water Supply connection From Municipal line)
TOTAL OF Part II-D : EXTERNAL WATER SUPPLY SYSTEM
Part-II- E : External Drainage System
Constructing fly ash / AAC /kiln burnt clay brick masonry Gully Trap chamber of following size and upto 600 mm initial depth including providing and fixing gully trap, consisting following items of work:- i) Providing square mouth uPVC gully trap of size 150 X 150 mm squre or 150mm dia with 110 mm outlet of Approved Make embedding in position in cement concrete 1:2:4 inside the chamber. ii) 230 mm thick brick masonry in 1:4 cement mortar over 150 mm thick cement concrete 1:2:4. iii) 15 mm thick plaster in cement mortar 1:3 on internal and external surfaces, internal surfaces and top finished with a floating coat of neat cement. iv) Providing and fixing precast approved make Composite(FRP/GRP) / CI / DI / SFRC Manhole covers & frame of size 300mm x 300mm as approved by E.I.C having loading capacity not less than HD20 with name of department and year engraved as specified / approved, including cost of necessary hardware and cement concrete / mortar for fixing the frame.
300 X 300 mm size Gully Trap chamber with FRP/GRP Composite frame and cover
Constructing fly ash / AAC /kiln burnt clay brick masonry Road Gully / Trap chamber of following size and upto 600 mm initial depth including fixing gully trap, consisting following items of work:- i) Fixing square mouth uPVC gully trap of size 150 X 150 mm squre or 150mm dia with 110 mm outlet of Approved Make embedding in position in cement concrete 1:2:4 inside the chamber. ii) 230 mm thick brick masonry in 1:4 cement mortar over 150 mm thick cement concrete 1:2:4. iii) 15 mm thick plaster in cement mortar 1:3 on internal and external surfaces, internal surfaces and top finished with a floating coat of neat cement. iv) Providing and fixing precast approved make Composite(FRP/GRP) / CI / DI / SFRC Manhole covers & frame of given size as approved by E.I.C having loading capacity not less than HD20 with name of department and year engraved as specified / approved, including cost of necessary hardware and cement concrete / mortar for fixing the frame.
450 X 450 mm size Road Gully Trap chamber with FRP/GRP Composite frame and gratting (HD20)
600 X 600 mm size Gully chamber and fixing FRP Composite frame and cover for initial internal depth of 600mm. NOTE: Excluding providing/suppling Frame & cover
Extra over above item no. 41.2 for additional depth of inspection chamber beyond 600 mm initial depth & upto a depth of 900 mm. all as per specification and as directed.
Providing & fixing square mouth uPVC gully trap of size 150 X 150 mm squre or 150mm dia with 110 mm outlet. As directed by Engineer-in-charge to complete the job.
Providing & laying UPVC under ground drainage pipes & Fittings of Approved make for storm water drains & Sewer lines of following size conforming to IS:15328 to proper level & grade, jointing including providing coupler with solvent cement / welded joints / as per manufacturer's requirement, encasing the pipe alround using cement concrete 1:3:6 complete if required all as per specifictions, drawing and as directed by the E.I.C. item includes Providing and fixing UPVC fittings such as Bendes, Tees & Y, Reducers, Blanking Plugs, Couplers, Adaptors etc For Sewer line and Storm water Drains NOTE:- Cement concrete for encasing shall be paid under relevant item.
110 mm DN (SN 8kN/m²-SDR34)
160 mm DN (SN 8kN/m²-SDR34)
200 mm DN (SN 8kN/m²-SDR34)
250 mm DN (SN 8kN/m²-SDR34)
315 mm DN (SN 8kN/m²-SDR34)
400 mm DN (SN 4kN/m²-SDR41)
Constructing fly ash / AAC /kiln burnt clay brick masonry Inspection chambers of internal sizes 900 X 600mm at bottom and 900 X 450mm at top for an initial depth of 600mm consisting following items of work. i) 230 mm thick brick masonry in cement mortar 1:2 over 150 mm thick bed in cement concrete of grade 1:2:4 with 150 mm offset all-around, tapering of longitudinal walls starting from the height of 450 mm from the top of chamber frame & cover and tapering of longitudinal walls ending at the height of 200 mm from the top of frame & Cover to obtain an internal dimensionof 900 X 450mm at 200 mm from top of chamber. ii) 20 mm thick plaster in cement mortar 1:1 mixed with water proofing compound @ 2% by weight of cement on internal and external surfaces, internal surfaces and top finished with a floating coat of neat cement. iii) Making benching and haunching in cement concrete of grade 1:2:4 and finishing with floating coat of neat cement. iv) Fixing frame and cover at top using cement concrete of grade 1:2:4 (for bed block / bearing course and capping) and cast iron steps / foot rests, all as per specification and as directed by Engineer in charge.
NOTE: i) Providing & fixing foot-rests/ steps and CI/ RCC/ Composite frame & cover including CC of grade 1:2:4 & C.M 1:2 plaster for fixing the frame and cover, will be paid under relevant item/ included in other relevant item. ii) Additional depth of chamber will be measured in cm and paid as per actual depth.
NOTE FOR INSPECTION CHAMBER & MANHOLE i) Depth of Inspection chamber shall be the vertical distance from the top of the frame & cover of manhole/ chamber to the outgoing invert of the main drain channel. ii) The internal diameter/ sizes of inspection chambers & manholes mentioned in the item shall be measured from finished plastered surfaces. iii) The cost of 1:2:4 grade concrete and plastering with CM 1:2 for fixing frame & cover is included under the scope of work of item for providing Everlast Cover iv) Slope of 1:6 for benching shall be started from channel of depth equal of the outgoing sewer diameter. v) The slope of conical wall of manhole and longitudinal walls of rectangular Inspection Chamber starts from the vertical height of 200mm from top of frame and cover. vi) While making payment for extra over initial depth, the thickness of RCC frame & cover and the thickness of cement concrete bed block (bearing course) shall not be deducted from the depth of manhole or chamber.
Inspection chamber of internal sizes 900 X 600 mm at bottom and 900 X 450 mm at top for an initial depth of 600 mm.
Extra over above item no. 43.1 for additional depth of inspection chamber beyond 600 mm initial depth & upto a depth of 1800 mm. all as per specification and as directed.
Construction of circular manhole of 1200 mm internal diameter at bottom and 530 / 560 / 600 mm at top for 1.5m initial depth & fly ash / AAC /kiln burnt clay brick masonry in 1:2 cement mortar, 230 mm thick wall for 1400 mm measured from top of frame & cover of manhole in conical shape and remaining height constructed 345 mm thick in cylindrical shape over a 300 mm thick cement concrete bed of grade 1:2:3 with 300 mm offset from outer finished wall surface of the manhole, also for benching and fixing frame & cover at top of brick masonry i.e. below and around frame and cover for bed block (bearing course) and capping including providing and fixing frame & cover, CI steps, 20mm thick plaster in 1:1 cement mortar mixed with water proofing compound @2% by weight of cement or or as per manufacturer's recommendation on internal and external surfaces, internal surfaces and channel finished smooth with floating coat of neat cement and external surfaces finished rough with wooden float, along the depth at juction where thickness of brick masonary changes and intermidiate depth/height not exeding 1m a RCC band of 230mm depth and width equal to brick wall shall be provided, all as per specifications, drawings and as directed by E-in-C.
NOTE:- Providing & fixing foot-rests / steps and CI / RCC / Composite frame & cover including CC of grade 1:2:4 for fixing the frame and cover - plastering in C.M 1:2 on exposed surfaces of bed block & capping, making smooth cement finish etc. will be paid under relevant item.
Top internal dia 530 / 560 / 600 mm to suit MD,HD & EHD cover for initial depth of 1.8m
Extra over Item No. 44.1 for additional depth of Chamber upto 3m.
Construction of circular manhole of 1500 mm internal diameter at bottom and 530 / 560 / 600 mm at top. Constructing fly ash / AAC /kiln burnt clay brick masonry in 1:2 cement mortar 230mm thk for initial 2.1m, 345mm thick wall from 2.1m to 2.85m, 460mm thick wall from 2.85m to 4.95m, 575mm thick wall from 4.95m to 9.0m, 690mm thick wall from 9.0m to 13.0m, measured from top of frame & cover of manhole in conical shape upto 2.85m from top and remaining height constructed in cylindrical shape over a 300 mm thick cement concrete bed of grade 1:2:3 with 300 mm offset from outer finished wall surface of the manhole, also for benching and fixing frame & cover at top of brick masonry i.e. below and around frame and cover for bed block (bearing course) and capping including providing and fixing frame & cover, CI steps, 20mm thick plaster in 1:1 cement mortar mixed with water proofing compound @2% by weight of cement or as per manufacturer's recommendation on internal and external surfaces, internal surfaces and channel finished smooth with floating coat of neat cement and external surfaces finished rough with wooden float, along the depth at juction where thickness of brick massonary changes and intermidiate depth/height not exeding 1m a RCC band of 230mm depth and width equal to brick wall shall be provided, all as per specifications, drawings and as directed by E-in-C.
NOTE:- Providing & fixing foot-rests / steps and CI / RCC / Composite frame & cover including CC of grade 1:2:4 for fixing the frame and cover - plastering in C.M 1:2 on exposed surfaces of bed block & capping, making smooth cement finish etc. will be paid under relevant item.
Top internal dia 530 / 560 / 600 mm to suit MD, HD & EHD cover for initial depth of 2.85m
Extra over Item No. 45.1 for additional depth of Chamber above 2.85m & upto 4.95m.
Providing & fixing precast approved brand FRP/GRP Composite Manhole covers as approved by Competant athority / E.I.C tested as per IS:1726, including cost of necessary hardware, 1:2:4 grade concrete for fixing frame, bed block (bearing course) and capping including necessary form work and CM 1:2 mortar for fixing the frame & for plastering exposed surfaces of concrete bed block (bearing course) and capping finished smooth with floating coat of neat cement etc., complete as per specifications, drawings and as directed by the E.I.C. Note: Shade and Colour and design pattern to be get approved from Engineer-in-Charge.
Rectangular Recessed Heavy duty (Grade HD - 20 designation as per IS:1726/ C-250 as per EN124 or higher loading class) frame and cover size 900 x 450mm
Square Recessed Heavy duty (Grade HD - 20 designation as per IS:1726/ C-250 as per EN124 or higher loading class) frame and cover size 600 x 600mm.
Square Recessed Heavy duty (Grade HD - 20 designation as per IS:1726/ C-250 as per EN124 or higher loading class) frame and cover size 900 x 900mm.
Circular Recessed Heavy duty (Grade HD - 20 designation as per IS:1726/ C-250 as per EN124 or higher loading class) frame and cover clear internal dia. 600mm
Rectangular Heavy duty (Grade HD - 20 designation as per IS:1726/ C-250 as per EN124 or higher loading class) frame and Grating size 300 x 700mm.
Providing and fixing Heavy duty SFRC type manhole cover conforming and tested as per IS:12592 of following size clear opening with frame and cover with provisions to match with surrounding finished level without any undulation for smooth running as approved and as specified having clear opening of given size and also covers have pick holes with a handle to lift manhole cover. It allows to fix with C:M 1:3 mortar with proper grading and on true line & level etc. complete as directed by EIC.
Square Heavy duty (Grade HD - 20 designation as per IS:12592) frame and cover size 600 x 600mm.
Square Heavy duty (Grade HD - 20 designation as per IS:12592) frame and cover size 1200 x 1200mm.
Providing and fixing copolymer polypropylene steel reinforced plastic Foot-rests / Steps of approved brand or eq. as per ASTM D - 4101 specification and moulded a 12 mm dia. IS - 1786 grade Fe - 415 steel reinforcing bar and in "U" shape having dimensions 263 x 168 mm and fixing in concrete / wall as shown in the drawing and as directed all complete.
Construction of Oil Grease trap of size 1000X900X2500 & 1000X600x2500mm Combined chamber including excavation, backfilling, watering, soling, compaction, Reinforcement etc. complete. It includes R.C.C work of for walls, top and bottom slabs, Rubble soiling and also having 100mm thick PCC in M-15 at bottom level. It shall be plastered with 20mm thick Plaster with neat coat in CM 1:3 on internal two coat at all sides. Top shall be covered with FRP Reccessed heavy duty Solid Top Manhole cover with clear opening of 600x600mm with frame and cover as Mentioned in Drawing. It shall be completed with all respect in ture line level, plumb with neat & clean surface as per coordinated infrastructure detail drawing up to the level of satisfaction.
Making new sewer connection with the existing manhole, which consist of making hole in the existing manhole with out causing any damage to the existing manhole, finishing the hole with cement mortar 1.1 (mixed with waterproofing compound) to the original condition after connecting the new sewer line to the existing manhole, disposing off the debris at directed place up to a lead of 150 metre all as per specifications and as directed by EIC. upto 600 mm nominal dia. pipe
Making connection to Municipal storm water line/ existing drain including breaking them in a systematic way with suitable excavation, dewatering, dismantling of the RCC or masonry wall or pipe line, passing the plumbing storm water line in the existing structure either through masonry or RCC and providing suitable "Y" tee to the connect to existing pipe line, Reconstructions of dismantled existing structure according to the original one to bring to the working conditions testing etc. work to be done in the presence of municipal eng. including Liasoning cost. complete as per standard as directed by Engineer-in-charge to complete the job. (Storm water connection to Municipal line)
TOTAL OF Part-II-E : Drainage System
PART-II-F : RWH Works
Construction of circular percolation well (PW) of 3000mm internal diameter with percolation bore having/including following items: 1. Constructing fly ash / ACC / kiln burnt clay brick masonry work (class of 7.5) in 1:4 cement mortar 230mm thk for initial 1.8m from finished ground level (FGL), 345mm thick wall from 1.8m to 3.6m from FGL, 460mm thick wall from 3.6m to 4.7m from FGL, 575mm thick wall from 4.7m to 5.05m from FGL, 805mm thick wall from 5.05m to 5.4m from FGL. 2. Providing and placing cement concrete 150mm thk bed of grade 1:2:3 with 150 mm offset from outer finished wall surface of the PW. 3. Providing and placing 230mm thk rubble soling of with 150 mm offset from outer finished PCC/CC of the PW. 4. Providing and placing RCC slab and beam including reinforcement as per design and drawing, of specified grade. 5. Providing 20mm thick plaster in 1:3 ready mix cement mortar on internal and external surface of PW. 6. Providing shuttering and scaffolding as per requirement.
7. Providing 110mm weep holes using 110 dia 6kg uPVC pipe as per design and drawing. 8. Providing inlet and outlet pipe connection as specified in drawing. Providing and fixing perforated uPVC 6kg pipe with perforated endcap and specials, fixtures, from inlet point to the granite slab. 9. Providing and placing Granite slab of size 0.8m x 0.8m and having thickness not less than 70mm, as per drawing. 10. Providing & fixing precast approved make 2 No. 600mm x 600mm clear opening FRP/GRP Composite Manhole covers (recessed or non recessed as per Architect) and frame of loading class HD-20 or higher as per IS:1726, including cost of necessary hardware, 1:2:3 grade concrete for fixing frame, bed block (bearing course) and capping including CM 1:2 mortar for fixing the frame & for plastering exposed surfaces of concrete bed block (bearing course) and capping finished smooth with floating coat of neat cement etc., complete as per specifications, drawings and as directed by the E.I.C.
11. Boring/Drilling bore well of 400 dia. by suitable method prescribed in IS: 2800 (Part-1), including collecting soil samples from different strata, preparing & submitting strata chart/ bore log, including hire & running charges of all equipment, tools, plants & machineries required for the job, all complete as per the direction of Engineer- in- Charge, Upto minimum 50 mtr. depth below ground level or upto the 2m above from aquifer whichever is higher. 12. Supplying, assembling, lowering & fixing in vertical position in the bore well, unplasticized PVC slotted and non slotted (casing) pipe of 250mm OD size, solvent cement jointed, class 5 (10kg) conforming to IS:4985, including jointing and suitable heavy fittings like elbows, collars, tees, unions, couplings, reducers, bends, enlargers, Coupler, End Cap, F.T.A., M.T.A., Reducer, Adapter and all other fittings required for the completion of laying and jointing as per IS:7634, including required Hire & labour charges, all complete for all depths as per drawings and as per the direction of EIC.
13. For ventilation of PW providing, fixing, laying, jointing & testing below the ground / above ground UPVC socketed 110 dia pipes for solvent cement joint CLASS 5 pipes as per IS:4985 (Agri pipe) including suitable heavy fittings like elbows, collars, tees, unions, couplings, reducers, bends, enlargers, flanged tailpieces, mosquito proof SS jali vent cowl and all other fittings required for the completion' laying and jointing as per IS, testing pipelines with fittings to be carried out using Hold-ties, Teflon tape, PVC & GI clamps, wooden gutties, SS screws, cement, solvent cement etc. required for the completion of the work and all as per specifications, drawings and direction of the Engineer-in-charge. 14. Supplying, filling, spreading & levelling filter media of following sizes in PW of 500mm depth for all leads & lifts all complete as directed by EIC. i. Coarse sand 1.5 to 2mm size, ii. Gravel 5mm to 10mm, iii. Boulders 40mm to 65mm. 15. Gravel packing in tube well construction ( Around casing pipe ) in accordance with IS:4097, including providing gravel fine/medium/course, in required grading & sizes as per actual requirement, all complete as per direction of EIC.
16. Providing and fixing copolymer polypropylene steel reinforced plastic Foot-rests / Steps of approved brand or eq. as per ASTM D - 4101 specification and moulded a 12 mm dia. IS - 1786 grade Fe - 415 steel reinforcing bar and in "U" shape having dimensions 263 x 168 mm and fixing in concrete / wall as shown in the drawing and as directed all complete. 17. Includes Excavation, dewatering, refilling the soil. All as per drawings, specifications and as directed by EIC.
TOTAL OF PART-II-F : RWH Works
PART-II-G : Contingent Mechanical Work to PH Works
Providing, fixing, testing and commissioning C.I. body, Motorised Butterfly valve (PN10 rating) of the following sizes with quarter turn, on/off electric actuator, SG Iron disc with EPDM/Nitrile seat, wafer type,with panel, IP-67 water tight alluminium enclosure with postion indicator, operated by level sensors and manually, VOLTAGE 220V AC., compatible with BMS system, complete with integration with level sensors as approved by Engineer-in-charge.
150 mm Dia
100 mm Dia
80 mm Dia
65 mm Dia
50 mm Dia
40 mm Dia
Providing and fixing enclosed type water meter (bulk type) of following size conforming to IS : 2373 and tested by Municipal Board complete with bolts, nuts, rubber insertions etc.
65 mm Dia
50 mm Dia
40 mm Dia
Each incomer and Outgoing feeder should be capable for protection against Overload, Short Circuit and Phase reversal condition and shall be capable to communicate with BMS. Scope shall also include supply, laying, termination of control and power cables of adequate size, and arrangement of cable tray from Pump to Control panel etc. to complete the job. SITC of elctronic type low water level controller with LED panel to operate pump (necessary contacts along with minium one spare contacts required), with probe & all control wiring to operate the system automatic/manual & shall prevent the pump from dry running. Mounting Height : 500mm from the bottom of tank. SITC of elctronic type low & high water level controller with LED panel to operate pump (necessary contacts along with minium one spare contacts required), level controller with operational mode as one pump working at low level, both pumps at high level with a hooter alarm and cut off at dry level with probe & all control wiring to operate the system automatic/manual & shall prevent the pump from dry running. Mounting Height (Low Level) : 500mm from the bottom of tank Mounting Height (Hight Level) : free board level of tank All Automatic valve to be Electronic operated. Location: TERRACE
RO WATER STORAGE TANK Supply, Installation, Testing & Commissioning of 1000LTR SS 316 Drinking Water storage tank Working Pressre - 6 Bar, test pressure shall be 1.5 time with flanged connection as required, capable of storing Cold water insulated with 50 mm thick PUF Insulation with 26 swg aluminium cladding. Shell shall be fabricated with 10 mm thick plate and dished ends with 12 mm thick plates complete with man hole cover, safety valve drain, nozzle, inlet and outlet nozzles industrial type temperature indicator. The storage tank shall be provided with Manhole Cover. item including of necessary supporting stand etc. complete the job. Location: TERRACE
Cooler with Storage tank for drinking station Supplying, Installation, testing and commissiong of 1000 Ltrs/hr size drinking water cooler storage type ISI marked, eco friendly non CFC refrigarant, water tank and cooler cabinet sheet material - stainless steel {gradeAISI304} with thickness >= 0.8mm, with PUF insulation including all accessories connection etc item including of necessary interconnection piping with control valve etc complete the job. Location: Terrace
Solar pannel for the hot water Supply of Solar Water Heating System of the CAPACITY: 300 LPD Pressurized consist of : Tank : 2.5mm with double internal layer of enamle, processed at 860 oC, according to DIN 4753 standard double jacket heat exchanger, 1.5 mm thick, Insulation: thermal insulation, ecological, >50kg/m3 external casing : marine grade alluminium alloy. capacity : 300 ltr maximum tested pressure : 15 bars maximum working pressure : 10 bars no. of collector : 2
HEAT PUMP Supplying, Installing, testing and commissioning of Air to Water Heat Pump capable of operation on air to water basis, . The Heat Pump System should be based on a open circuit hot water design temperature of 60 °C out of the unit with 20°C input water temorature for operation . Heat Pump Capacity : 2000 LPH / Pump Refrigerent - R407C/ 410a/ R134a Total Heating Capacity of System: As per Vendor Out Put Heating Capacity : As per Vendor Power Connected Load – As per Vendor COP : 3.5 to 4 Set of inter connecting GI C Class Piping with Insulation , all valves , Stainers , Pressue Guages , Temprature Guages Provided as per requirement. All the pipes and fittings shall be insulated with 50mm Rock wood insulation with 26G Aluminium Cladding The unit shall have all electrical and Hydraulica safety devises inbuilt. These units shall be completely factory assembled including thermetic scroll compressor, air cooled condenser. Machine is equipped with microprocessor based control, safety device, digital display unit, electrical panel, inbuilt pumping system & Self cleaning system
Quantity:(Working + Partial Stand by) with Automatic Cascade Operation Single point power and Single point water supply shall be provided by user. Location : At terrace
Set of accessories such as GI headers of suction and discharge for (working and stand by pump assembly), control valves, non return valves, pressure switches, pressure transducers, pressure gauge of PN 10 etc. complete the job. Capacity per pump - 5m3/hour, Head - 30mt, 1Set = 2Nos. Pump (1Working + 1Standby - cascade operation),
HOT WATER STORAGE TANK 5000 LTR Storage Glass Enemel Tank with 50 mm PUF Insulation, Tank working Pressure 6 Kg and Test Pressure 8 Kg.Inlet outlet connection size as per design. Make Benchmark, Ao Smith, 1500 LTR GLASS ENAMEL HOT WATER COLLECTION TANK
R.O. with Cooler for drinking station Water Storage Capacity – Warm 40 liter. Water Storage Capacity – Cold 40 liter. Water Storage Capacity – Normal 40 liter. Water Cooling Capacity :40 LPH *Output water temperature being 17°c Instant warm water supply : 40 LPH 1KW Geyser No. Of Faucet : 3 faucets (1 warm, 1 cold & 1 normal) Dynamic monitor and controller (DMC) 3 faucets (1 warm, 1 cold & 1 normal) bar graph for Cartridge life, Pump status, No Water,Flushing of membranes. Outer Body Material Full SS Outer Body Dimensions (LxWxH) (mm) 1155 x 575 x 1335 Net Weight 119 kgs ± 2 kgs Refrigeration – Green (eco) gas R-134 A Green Gas Operating Voltage 230 ± 10%V AC, 50Hz Power Consumption in watts (Max) 1.3 ± 0.1 KW Purification Capacity Up to 100 ltrs/hour* Pure water recovery Up to 70% Auto Sanitization – Storage Tank ESS – Electrolytic Sanitizing System – Active Silver protects storage water tank from external contaminations and offers pure water for 24×7.
Pond WATER TREATMENT PLANT Supply Installation, Testing and Commissioning of Pond Water Treatment Plant comprising of Pipe Flocculator, pH correction Dosing system, coagulant Dosing pump, Flocculant Dosing accrording to input water quality/analysis. This water treatment plant shall be operated for monsoon/pond water treatment having Multimedia Filter as per requirment. Required CPVC SCH 80 piping, isolation valves, instruments supports in vendor scope. The scope shall include CPVC SCH 80 interconnection piping, Butterfly Cast Iron valves, NRV, instruments, .Scope shall also includes one month operation including consumable and training for operation of staff. Required civil work for this pond water treatment plant is not in vendor scope. Inlet Flow Range : 30 m3/hour Output Water Turbidity : < 05 PPM
RAINWATER HEAVESTING WATER TREATMENT PLANT Supply Installation, Testing and Commissioning of Pond Water Treatment Plant comprising of Pipe Flocculator, pH correction Dosing system, coagulant Dosing pump, Flocculant Dosing accrording to input water quality/analysis. This water treatment plant shall be operated for monsoon/pond water treatment having Multimedia Filter as per requirment. Required CPVC SCH 80 piping, isolation valves, instruments supports in vendor scope. The scope shall include CPVC SCH 80 interconnection piping, Butterfly Cast Iron valves, NRV, instruments, .Scope shall also includes one month operation including consumable and training for operation of staff. Required civil work for this pond water treatment plant is not in vendor scope. Inlet Flow Range : 30 m3/hour Output Water Turbidity : < 05 PPM
HYDRO PNEUMATIC SYSTEM FOR Domestic Water Distribution, Variable Speed Hydro-booster System Compact self contained Hydro-booster system comprising of following SITC of In-line, vertical multistage, centrifugal clear water pumps with SS-304 casing, S.S 304 impeller and SS-304 shaft, C.I. Base CED (Cathode Electrode Deposition) coating & head TEFC motor (with mechanical seal), dry run protection, antivibration paid, 2 pole Motor & IE3 Efficiency. Vendor to submit performance curves and technical catalogue of the proposed model for review and information. Panel mounted microprocessor based multi pump controller with large graphical display with VGA 240 x 320 pixels and variable frequency drive (VFD) integrated in a single body, pressure sensor transmitter, IP 55 enclosure, diodes to indicate pump ready, earthing, pump running and fault condition, Cascade Operation. Each incomer and Outgoing feeder should be capable for protection against Overload, Short Circuit and Phase reversal condition and shall be capable to communicate with other controllers following. The PLC shall support MODBUS-IP communication for its compatability to intergrate with 3rd party BAS system.
Controller shall authorise Read/Write command via BMS.System should be capable to compensate for frictional losses at lower flows. All alarms should be displayed in the controller. System should be equipped with dry running protection. Indication of all type of faults / on-off status / electrical parameters shall be available on panel and central IBMS monitors. On-off operation for all pumps shall be available on BMS system. Electronic type low water level controller with LED panel to operate pump (necessary contacts along with minimum one PLC operated spare contacts required), with probe & all control wiring from Panel to tank to operate the system automatic/manual & shall prevent the pump from dry running. Scope shall also include power and control cable of required size, termination, cable tray from Pump to Control panel, control cable as whereever required etc. complete the job. Pre-charged diaphragm pressure vessel with interchangeable membrane, charging connection, connected to outlet header with necessary flanges, gaskets, isolating valves, nuts/bolts etc. complete (size of pressure vessel shall be as per manufacturer recommendation).
Set of accessories such as GI C Class headers of suction and discharge for (working and Standby pump assembly) with CED Coating, Cast iron control valves, Cast Iron non return valves, pressure transducers, pressure gauge with Isolation Valve of PN 10 etc. complete the job.Require complete company fitted ready-to-connect packaged system. Capacity per pump - 16.0 m3/hour, Head -70 mt, 1 Set = 3 Nos. Pump (2 Working + 1 Standby - cascade operation), Location - UGT Pump Room, Suction head - flooded positive suction
HYDRO PNEUMATIC SYSTEM FOR Domestic Water Distribution, Variable Speed Hydro-booster System Compact self contained Hydro-booster system comprising of following SITC of In-line, vertical multistage, centrifugal clear water pumps with SS-304 casing, S.S 304 impeller and SS-304 shaft, C.I. Base CED (Cathode Electrode Deposition) coating & head TEFC motor (with mechanical seal), dry run protection, antivibration paid, 2 pole Motor & IE3 Efficiency. Vendor to submit performance curves and technical catalogue of the proposed model for review and information. Panel mounted microprocessor based multi pump controller with large graphical display with VGA 240 x 320 pixels and variable frequency drive (VFD) integrated in a single body, pressure sensor transmitter, IP 55 enclosure, diodes to indicate pump ready, earthing, pump running and fault condition, Cascade Operation. Each incomer and Outgoing feeder should be capable for protection against Overload, Short Circuit and Phase reversal condition and shall be capable to communicate with other controllers following. The PLC shall support MODBUS-IP communication for its compatability to intergrate with 3rd party BAS system. Controller shall authorise Read/Write command via BMS.System should be capable to compensate for frictional losses at lower
flows. All alarms should be displayed in the controller. System should be equipped with dry running protection. Indication of all type of faults / on-off status / electrical parameters shall be available on panel and central IBMS monitors. On-off operation for all pumps shall be available on BMS system. Electronic type low water level controller with LED panel to operate pump (necessary contacts along with minimum one PLC operated spare contacts required), with probe & all control wiring from Panel to tank to operate the system automatic/manual & shall prevent the pump from dry running. Scope shall also include power and control cable of required size, termination, cable tray from Pump to Control panel, control cable as whereever required etc. complete the job. Pre-charged diaphragm pressure vessel with interchangeable membrane, charging connection, connected to outlet header with necessary flanges, gaskets, isolating valves, nuts/bolts etc. complete (size of pressure vessel shall be as per manufacturer recommendation).
Set of accessories such as GI C Class headers of suction and discharge for (working and Standby pump assembly) with CED Coating, Cast iron control valves, Cast Iron non return valves, pressure transducers, pressure gauge with Isolation Valve of PN 10 etc. complete the job.Require complete company fitted ready-to-connect packaged system. Capacity per pump - 6.0 m3/hour, Head -70 mt, 1 Set = 3 Nos. Pump (2 Working + 1 Standby - cascade operation), Location - UGT Pump Room, Suction head - flooded positive suction
HYDRO PNEUMATIC SYSTEM FOR RAINWATER HARVESTING TANK TO DOMESTIC WATER TANK, Variable Speed Hydro-booster System Compact self contained Hydro-booster system comprising of following SITC of In-line, vertical multistage, centrifugal clear water pumps with SS-304 casing, S.S 304 impeller and SS-304 shaft, C.I. Base CED (Cathode Electrode Deposition) coating & head TEFC motor (with mechanical seal), dry run protection, antivibration paid, 2 pole Motor & IE3 Efficiency. Vendor to submit performance curves and technical catalogue of the proposed model for review and information. Panel mounted microprocessor based multi pump controller with large graphical display with VGA 240 x 320 pixels and variable frequency drive (VFD) integrated in a single body, pressure sensor transmitter, IP 55 enclosure, diodes to indicate pump ready, earthing, pump running and fault condition, Cascade Operation. Each incomer and Outgoing feeder should be capable for protection against Overload, Short Circuit and Phase reversal condition and shall be capable to communicate with other controllers following. The PLC shall support MODBUS-IP communication for its compatability to intergrate with 3rd party BAS system. Controller shall authorise Read/Write command via BMS.System should be capable to compensate for frictional losses at lower
flows. All alarms should be displayed in the controller. System should be equipped with dry running protection. Indication of all type of faults / on-off status / electrical parameters shall be available on panel and central IBMS monitors. On-off operation for all pumps shall be available on BMS system. Electronic type low water level controller with LED panel to operate pump (necessary contacts along with minimum one PLC operated spare contacts required), with probe & all control wiring from Panel to tank to operate the system automatic/manual & shall prevent the pump from dry running. Scope shall also include power and control cable of required size, termination, cable tray from Pump to Control panel, control cable as whereever required etc. complete the job. Pre-charged diaphragm pressure vessel with interchangeable membrane, charging connection, connected to outlet header with necessary flanges, gaskets, isolating valves, nuts/bolts etc. complete (size of pressure vessel shall be as per manufacturer recommendation).
Set of accessories such as GI C Class headers of suction and discharge for (working and Standby pump assembly) with CED Coating, Cast iron control valves, Cast Iron non return valves, pressure transducers, pressure gauge with Isolation Valve of PN 10 etc. complete the job.Require complete company fitted ready-to-connect packaged system. Capacity per pump - 15.0 m3/hour, Head -50 mt, 1 Set = 3 Nos. Pump (2 Working + 1 Standby - cascade operation), Location - STP Pump Room, Suction head - flooded positive suction
Electromagnetic Water Meter- AMR Based: Design, Supply, Installation, Testing, Commissioning of electromagnetic Water Meter, CI/ Brass/ Bronze body material, totalizer made of copper can/ suitable anti corrosive metallic material, totaliser metalic shall have 5 mm thick glass cover suitable against antifraud attempts, Flange End process connection, IP 68 protection class, AMR Woltman Type Water Meter with removable mechanism, magnetic drive, dry dial, and be fitted with a low mass rotor which is parallel to the direction of water flow and exhibits dynamic thrust relief, water meters complete with T Type strainer, ISO 4064 : 2005 with valid CE mark mentioning notified body number along with MlD / OIML / ISO certification from a recognized International laboratory. AMR System :AMR System shall be Walk By / Drive By mode, Wireless AMR trans-receivers shall be directly fitted on meter or inbuilt, IP 68 protection class, water meter & AMR Module shall be of same brand, Single Command based AMR Reading and Minimum 90 days historical data retrive facility, alaram indication/ recording (for Reverse Flow, back flow, Peak Flow,Minimum Flow, Low Battery Alram, Volume below threshold, Volume above threshold, Reverse Meter, Meter Stopped), Minimum 10 years of AMR module bateery life considering one no. communication per day.
Water Meter: 100mm
Water Meter: 80mm
Water Meter: 65mm
Water Meter: 50mm
Providing supplying and fixing of Organic Waste Converter of capacity of 450Kg/day. (Plot-A & B Phase -I) Technical specification of System:- Organic Waste Machine OR composting machines to be used to effectively dispose of organic wastes (food waste and similar biodegradable wastes) in Vegetable, fruits, kitchen waste etc. The unit can efficiently treat organic waste resulting in volume reduction of upto 90% and convert the residual material into high quality compost. This fully automated composting machine can be used onsite and is capable of reducing solid waste from food sources, marine products and agriculture resources into high quality compost in an eco-friendly manner. The end product i.e high quality compost can be used for horticulture/gardening. OWC machine Composter is fully automatic and compact in size, housing with epoxy painted and Composite reactor tank material (Blades, shaft, input & output door) shall be of Stainless steel-304 Grade, processes all types of organic waste, Noiseless, Odourless, Maintenance-free, No harmful gases let out, No pathogens and does not need a skilled person to operate it. The minimum requirement is as Shrader inbuilt helical gearbox, Mixer motor with planetary gearbox, Blower 1.50 HP Min., External body shall be in M.S plate with paint, Machine heating System shall be with suitable
Ceramic Coil. Overall space for operation of 450 KG per day OWC shall be 4.00 mtr X 2.40 mtr X 3.60 mtr (LXWXH) with 6" plinth required base support foundation, FRP shed, incoming power cable with MCCB suitable for 20 KW power rating. (this power connection , foundation and FRP shed work in Civil Contractor’s scope.) Panel for auto operation of OWC in OWC supplier scope. This organic waste converter can efficiently mix organic waste and convert the same into compost. This fully automated composting machine can be used on-site and is capable of reducing solid waste from food sources, marine products and agriculture resources into high quality compost in an eco- friendly manner. The unit is a fully enclosed automatic composting machine that disposes of any food matter. A rotating arm inside the machine slowly churns the waste food to constantly mix the organic waste The process is a practical alternative to traditional waste disposal. The composting machine is designed for all types of cooked and uncooked vegetables, fruits, fish, poultry and meat products, dairy, wheat, flour, rice, tea, coffee, grass clippings, leaves and all such types of processed and unprocessed biodegradable waste. The composting process takes place in a closed composting barrel, preventing any external handling or contamination, while eliminating any sources of food for insects and rodents.
The composters are sealed to prevent odors to be released, eliminating in this way a common nuisance and source of public complaints frequent in open air or traditional composting sites. This composter is designed and manufactured according to the toughest industry standards. High quality materials and components coupled with a responsive technical after sales team provide a long service life and faultless reliability. Make:- Kelvin/ECS/Ecobot Salient Features and Advantages. • Fully Automatic and compact in size., • All contact parts are in Stainless Steel construction.• Processes all types of organic waste (Canteen Waste, Kitchen Waste and garden Waste).• Volume reduction of organic waste into high quality compost.• Ready compost in 24 hours.• Noiseless, Odorless, Maintenance-free.• No harmful gases. • No pathogens.• Reduces large amounts spent on transportation to landfill sites.• In-house waste management reducing dependence on any outside agency.• Segregation and separation of the organic waste.• Inbuilt Shredding of the organic waste while feeding in the composter.• Processing in the composter. • Finished ready compost for use. Inclusive-• Unloading and placement the machine at installation site.• Installation, Testing and commissioning of Machine.
Mode of Measurements: The rate shall include the cost of all materials, labours etc. complete as specified in the Item. The rate shall be measured in No. Basis. Civil work, FRP shed and Incoming power cable with MCCB is not included in this Line Item.
HYDRO PNEUMATIC SYSTEM FOR Irrigation Water Distribution, Variable Speed Hydro-booster System Compact self contained Hydro-booster system comprising of following SITC of In-line, vertical multistage, centrifugal clear water pumps with SS-304 casing, S.S 304 impeller and SS-304 shaft, C.I. Base CED (Cathode Electrode Deposition) coating & head TEFC motor (with mechanical seal), dry run protection, antivibration paid, 2 pole Motor & IE3 Efficiency. Vendor to submit performance curves and technical catalogue of the proposed model for review and information. Panel mounted microprocessor based multi pump controller with large graphical display with VGA 240 x 320 pixels and variable frequency drive (VFD) integrated in a single body, pressure sensor transmitter, IP 55 enclosure, diodes to indicate pump ready, earthing, pump running and fault condition, Cascade Operation. Each incomer and Outgoing feeder should be capable for protection against Overload, Short Circuit and Phase reversal condition and shall be capable to communicate with other controllers following. The PLC shall support MODBUS-IP communication for its compatability to intergrate with 3rd party BAS system.
Controller shall authorise Read/Write command via BMS.System should be capable to compensate for frictional losses at lower flows. All alarms should be displayed in the controller. System should be equipped with dry running protection. Indication of all type of faults / on-off status / electrical parameters shall be available on panel and central IBMS monitors. On-off operation for all pumps shall be available on BMS system. Electronic type low water level controller with LED panel to operate pump (necessary contacts along with minimum one PLC operated spare contacts required), with probe & all control wiring from Panel to tank to operate the system automatic/manual & shall prevent the pump from dry running. Scope shall also include power and control cable of required size, termination, cable tray from Pump to Control panel, control cable as whereever required etc. complete the job. Pre-charged diaphragm pressure vessel with interchangeable membrane, charging connection, connected to outlet header with necessary flanges, gaskets, isolating valves, nuts/bolts etc. complete (size of pressure vessel shall be as per manufacturer recommendation).
Set of accessories such as GI C Class headers of suction and discharge for (working and Standby pump assembly) with CED Coating, Cast iron control valves, Cast Iron non return valves, pressure transducers, pressure gauge with Isolation Valve of PN 10 etc. complete the job.Require complete company fitted ready-to-connect packaged system. Capacity per pump - 8.0 m3/hour, Head -50 mt, 1 Set = 3 Nos. Pump (2 Working + 1 Standby - cascade operation), Location - STP Pump Room, Suction head - flooded positive suction
HYDRO PNEUMATIC SYSTEM FOR Pond to STP treated water tank, Variable Speed Hydro-booster System Compact self contained Hydro-booster system comprising of following SITC of In-line, vertical multistage, centrifugal clear water pumps with SS-304 casing, S.S 304 impeller and SS-304 shaft, C.I. Base CED (Cathode Electrode Deposition) coating & head TEFC motor (with mechanical seal), dry run protection, antivibration paid, 2 pole Motor & IE3 Efficiency. Vendor to submit performance curves and technical catalogue of the proposed model for review and information. Panel mounted microprocessor based multi pump controller with large graphical display with VGA 240 x 320 pixels and variable frequency drive (VFD) integrated in a single body, pressure sensor transmitter, IP 55 enclosure, diodes to indicate pump ready, earthing, pump running and fault condition, Cascade Operation. Each incomer and Outgoing feeder should be capable for protection against Overload, Short Circuit and Phase reversal condition and shall be capable to communicate with other controllers following. The PLC shall support MODBUS-IP communication for its compatability to intergrate with 3rd party BAS system.
Controller shall authorise Read/Write command via BMS.System should be capable to compensate for frictional losses at lower flows. All alarms should be displayed in the controller. System should be equipped with dry running protection. Indication of all type of faults / on-off status / electrical parameters shall be available on panel and central IBMS monitors. On-off operation for all pumps shall be available on BMS system. Electronic type low water level controller with LED panel to operate pump (necessary contacts along with minimum one PLC operated spare contacts required), with probe & all control wiring from Panel to tank to operate the system automatic/manual & shall prevent the pump from dry running. Scope shall also include power and control cable of required size, termination, cable tray from Pump to Control panel, control cable as whereever required etc. complete the job. Pre-charged diaphragm pressure vessel with interchangeable membrane, charging connection, connected to outlet header with necessary flanges, gaskets, isolating valves, nuts/bolts etc. complete (size of pressure vessel shall be as per manufacturer recommendation).
Set of accessories such as GI C Class headers of suction and discharge for (working and Standby pump assembly) with CED Coating, Cast iron control valves, Cast Iron non return valves, pressure transducers, pressure gauge with Isolation Valve of PN 10 etc. complete the job.Require complete company fitted ready-to-connect packaged system. Capacity per pump - 15.0 m3/hour, Head -50 mt, 1 Set = 3 Nos. Pump (2 Working + 1 Standby - cascade operation), Location - STP Pump Room, Suction head - flooded positive suction
Design, supply, installation, testing, and commissioning of a submersible dewatering pump set with a discharge capacity of 3 m³/hr and a total head of 20 meters. The pump set shall operate on a 3-phase, 415 V AC power supply with a motor speed of 1500 RPM, featuring a continuous-rated squirrel cage induction motor with class-F insulation. The system includes a 40 mm diameter GM gate valve at the outlet, and either a GI (Heavy class) or CPVC or PVC flexible hose pipe for delivery, with a diameter of 40 mm and an approximate length of 70 meters. This item covers all necessary fittings, flanges, valves, jointing, supports, and painting. Additionally, the cost includes all items, accessories, fittings, tools, and tackles required for installation, including the construction of a pit for installing the pump into an underground tank and packing for putting the pump into service. All work shall be completed as per the specifications and directions of the Engineer In Charge (EIC)
TOTAL OF PART-II-G : Contingent Mechanical Work to PH Works
PART-II-H : Landscape Irrigation System Work SPRINKLER , DRIP & HYDRANT IRRIGATION SYSTEM
Providing, installing, testing and commissioning of HDPE pipes confirming to IS 4984 or ISO 4427 suitable for the respective working pressures with all electrofusion or compression type PN16 fittings and accessories e.g. couplings, tees, bends, reducers, screwed adapters, flanged tail pieces etc. jointing as per manufacturers' instruction,with Excavation & Backfilling upto 600mm for main and 450 mm for submian depth Make : Approved Makes
HDPE Pipe 110mm PN 8
HDPE Pipe 90mm PN 8
HDPE Pipe 75mm PN 8
Piping Network Providing & fixing of following dia. white PVC pipe conforming to ASTM D 1785 SCH 40 or D 2241 Class 200/315 standards with all fittings and accessories e.g. couplings, tees, bends, reducers, screwed adapters, flanged tail pieces etc. as required with Excavation & Backfilling upto 450mm for for submian depth. Make:Approved Makes
PVC Pipe Sch 40 / Class 200 2.5" - 65mm
PVC Pipe Sch 40 / Class 200 2" - 50mm
PVC Pipe Sch 40 / Class 200 1-1/2" - 40mm
PVC Pipe Sch 40 / Class 200 1-1/4" - 32mm
Drip & Accessories
Providing, installing, testing and commissioning of 16mm inline tubing with pressure compensating,, Flat emitter and resistance to UV damage, algae growth brown in colour from outer surface and black innter surface, with flow rate 3.4 lph, dripper spacing 18" Pressure rating 0.58 to 4.1 kg/cm2 wall thickness 1.2mm The flexible polyethylene tubing shall have factory-installed pressure-compensating, inline emitters installed every 18 inches. The flow rate from each installed inline emitter shall be 3.4 Litre per hour. The inline emitter shall be pressure compensating with a spring-action design which will provide a a self-rinsing mechanism if grit accumulates within the emitter. The bend radius shall be 3 inches whether bending the tubing with the natural bend of the coil or against it. The inline emitter inlet shall be raised off the inside tube wall to minimize dirt intrusion. Make: Rainbird/Smartflows/Toro/Netafim
Providing, installing, testing and commissioning of High Quality kg/cm2bs Grab Tubing for a Secure Fit. Unique kg/cm2b Design to Reduce Insertion Force. Non - Obtrusive 17mm Insert Fittings - Brown Color - Take Off Adopter, Elbow,Tees, End Cap with PP Clamp Saddle having nuts and bolts in zinc chromed steel, o-ring gasket in NBR. Male: Rainbid/Toro/Smartflows/Netafim or approved equivalent Make
Providing, installing, testing and commissioning of 9" Long Galvanized Lateral Hold Stake Make: Rainbird/Toro/Smartflows/Netafim or approved equivalent Make
Sprinklers & Accessories
Providing, installing, testing and commissioning of Supply,Fixing & commissioning of 3/4" Rotor pop up sprinkler full/part circle having radius of 10m - 12m @ 2.5 kg/cm2 with discharge of 0.22 ltr./sec. the sprinklers having Arc Adjust through Top Cover w/ Std. Screwdriver The sprinkler is gear driven rotary type with having 3/4" bottom inlet. Oversized wiper seal, Rain Curtain technology, gentle close-in watering and Self-flushing arc adjustment port and also having tapered riser stem with Wiper Seal The sprinkler shall have Plus (PL) Flow shut off feature for maintanace and nozzle insertion online, 45 psi pressure regulator with flow optimizer technology, internal Seal - A - Matic device which prevents low head drainage (upto 3.1m) & hence puddling & erosion. The body of sprinkler should be of non - corrodible, heavy duty, ABS plastic.O-ring Slip Clutch,Racheting Slip Clutch and having 4” (10.2 cm) pop-up height to center line of nozzle to clears taller turfgrass Make: Rainbird/Toro/Weathematics or approved equivalent Make
Providing, installing, testing and commissioning of 3/4" x 12" Long Pop up Connecting Swing joint Assembly. The tubing shall be made of polyetylene having wall thickness of 2.3mm ,a working pressure of 5.5 kg/cm2 at 43oC and a surge pressure of 16.6 kg/cm2. Flex pipe textured for wet conditions.The fittings shall be made of UV resistant thermo plastic with PP Clamp Saddle Chromed Nut Bolt & Nitrile Rubber Gasket. Make: Lasco/Toro/Rainbird/Smarflows/Astore or approved equivalent Make
Providing, installing, testing and commissioning of 4" Pop up spray head with SAM PRS Series Spray bodies , having Co-moulded wiper seal is moulded into the cap and features an encased plastic 'cage' to provide resistant to grit, with Rotary nozzle having mutilple stream MPR sprayhaving Co-moulded wiper seal is molded into the cap and features an encased plastic 'cage' to provide unmatched resitence to grit, nozzle capable of covering 4.0-7.3m at 1.4 - 3.8 kg/cm2s pressure, and the enviroment. Rotary nozzles shall have hand adjustable ( without tools) radius and arc-45 to 270 degree or full circle,True flushing mechanism,Thick streams and large water droplet & Low precipitation rate. Make: Rainbird/Toro/Weathermatics or approved equivalent Make
Providing, installing, testing and commissioning of 1/2" x 12" Long Pop up Connecting Swing joint Assembly. The tubing shall be made of polyetylene having wall thickness of 2.3mm ,a working pressure of 5.5 kg/cm2 at 43oC and a surge pressure of 16.6 kg/cm2. Flex pipe textured for wet conditions.The fittings shall be made of UV resistant thermo plastic with PP Clamp Saddle Chromed Nut Bolt & Nitrile Rubber Gasket Make:Lasco/Toro/Rainbird/Smarflows/Astore or approved equivalent Make
Valves Providing of Various Valves with required Fittings & Tapping PP Clamp Saddles with Chromed Nut Bolt & Nitrile Rubber Ring
Providing, installing, testing and commissioning of PVC Ball Valve 63mm Make : Astore / FIP / GF or approved equivalent Make
Providing, installing, testing and commissioning of PVC Ball Valve 40mm Make : Astore / FIP / GF or approved equivalent Make
Providing, installing, testing and commissioning of PVC Butter Fly Valve 90mm (3") PN 10, having EPDM Seals, Galvnized Steel Stem Disc - PVC U Make: Astore/GF/FIP or approved equivalent Make
Providing, installing, testing and commissioning of PVC Butter Fly Valve 75mm (2.5") PN 10, having EPDM Seals, Galvnized Steel Stem Disc - PVC U Make: Astore/GF/FIP or approved equivalent Make
Providing, installing, testing and commissioning of PVC Flush Valve 40mm Make: Rainbird/Smartflows/Netafim or approved equivalent Make
Providing, installing, testing and commissioning of 3/4" Quick Couppling Valve Make: Rainbird/Toro/Smartflows or approved equivalent Make
Providing, installing, testing and commissioning of 3/4" Quick Couppling Valve Key Make Rainbird/Toro/Smartflows or approved equivalent Make
Providing, installing, testing and commissioning of Saddle Tee 160/140/110/90/75/63mmX3/4" witth ASTM Pipe (12" Long) Make Asore/Smartflows/Astral or approved equivalent Make
Providing, installing, testing and commissioning of Swivel Elbow 3/4" X 3/4" - Rainbird/Toro/Smartflows or approved equivalent Make
Providing, installing, testing and commissioning of 1" - 25mm Double Acting Air cum Vacum Release Valve, Body: Glass-reinforced Nylon, Float Assembly: Polypropylene, Elastomers: EPDM, operating pressure minimum 0.1 kg/cm2, maximum 10 kg/cm2, Aerodynamic full-body kinetic shield, Straight flow body with large diameter orifice size 0.787mm dia and area of 0.496 sqmm Make:Bermad/Rainbird/Crispin or approved equivalent Make
Providing, installing , testin and commissioning of PP Saddle Tee 160/140/110/90/75/63mmX1" witth ASTM Pipe (12" Long) Make: Astore/Smartflows/FIP/Astral or approved equivalent Make
Providing, installing, testing and commissioning of 12" Rectangular Standard Commercial grade Valve Box with greenlid and corrugated structure with unique shovel access slot and bolt hole knockout & having Dimensions @ Top Opening:14.5" L X 9.4" W 12.1" H & bottom opening :18.7" L X 14.1"W with Nut Bolt Lock Make: RainBird/Toro/Smarflows or approved equivalent Make
Providing, installing, testing and commissioning of 10" Round Valve Box with greenlid and corrugated structure with unique shovel access slot and bolt hole knockout & Having Dimensions @ Top Opening 8.9" Dia & Bottom Opening 11.9" Dia,with Nut Bolt Lock, Make: RainBird/Toro/Smarflows or approved equivalent Make
Providing, installing, testing and commissioning of 6"Round box with greenlid Having Dimensions @ Top Opening :6 1/8" Dia & Bottom Opening 8 5/8" Dia, with Nut Bolt Lock, Make: RainBird/Toro/Smarflows or approved equivalent Make
Providing, installing, testing and commissioning of 12" Jumbo Rectangular Standard Commercial grade Valve Box with greenlid and corrugated structure with unique shovel access slot and bolt hole knockout & having Dimensions @ Top Opening:18.7" L X 12.2" W & bottom opening :24" L X 17.5 "W X 12.1" H, with Nut Bolt Lock Make: RainBird/Toro/Smarflows or approved equivalent Make
Providing, installing, testing and commissioning of 4.0" Hydro Meter - Water Meter cum Master Valve in one common body Make:Rainbird/Bermad/Smartflows/Cal-Valve or approved equivalent Make
Providing, installing, testing and commissioning of 2.0" Hydro Meter - Water Meter cum Master Valve in one common body Make:Rainbird/Bermad/Smartflows/Cal-Valve or approved equivalent Make
Automation Providing Automation Items for Irrigation with all its required accessories.
Providing, installing, testing and commissioning of 230V Input, DC output Irrigation Controller combines electromechanical and microelectronic circuitry capable of fully automatic or manual operation. Make:Netafim/Toro/Rainbird or approved equivalent Make
Providing, installing, testing and commissioning of D.C. 2"-50mm Durable Glass filled nylon Solenoid Valve - BSP Female Threaded, with Nylone scrubber / Filter Sentry Pressure - 1 to 13.8 kg/cm2 along with Filed Device - DC Solienoid Coil with interface module in-built in one device mountable on Solenoid Valve to connect Controller and Valve on one wire path Make: Bermad/Netarim/RainBird/Toro or approved equivalent Make
Providing, installing, testing and commissioning of D.C. 1.5"-40mm Durable Glass filled nylon Solenoid Valve - BSP Female Threaded, with Nylone scrubber / Filter Sentry Pressure - 1 to 13.8 kg/cm2 along with Filed Device - DC Solienoid Coil with interface module in-built in one device mountable on Solenoid Valve to connect Controller and Valve on one wire path Make: Bermad/Netarim/RainBird/Toro or approved equivalent Make
Providing, installing, testing and commissioning of FLOW Sensor Make: Bermad/Netarim/RainBird/ Toro or approved equivalent Make
Providing, installing, testing and commissioning of Rain Sensor Make: Bermad/Netarim/RainBird/Toro or approved equivalent Make
Providing, installing, testing and commissioning of Maxi Jackated Direct Burrial Irrigation Automation Cable 14 AWG Tin coated copper conductors, insulated with PVC and having a high density polyethylene direct burial jacket. Conductor - Soft annealed tin coated solid copper conforming to ASTM B-33. Insulation: Polyvinyl Chloride conforming to UL Standard 493 for TYPE UF/TWU rated 75°C. Outer Jacket: Pressure Extruded High Density PE conforming to ICEA S-61-402, and NEMA WC5 Jacket Thickness 3/64" minimum jacket material to completely fill interstices between the two insulated conductors. Make: RainBird/Paige/Smartflows/Toro or approved equivalent Make
Providing, installing, testing and commissioning of Pressure Regulatr to Maintain constant outlet pressure between 1.04 to 6.9 Kg/cm2 Make: Bermad/Netarim/RainBird/Toro or approved equivalent Make
Providing, installing, testing and commissioning of direct bury -on wire connector with strain relief ,UL486 D certified ,with waterproof silicon sealant ,fits wire from 22ga to6 ga as per specifications complete. Make 3M/Smartflows/Rainbird or approved equivalent Make
Providing, installing, testing and commissioning of Surge Protector Make: Bermad/Netarim/RainBird/ Toro or approved equivalent Make
Providing, installing, testing and commissioning of Copper Grounding Rod 5/8" x 8' Make: Paige/Smartflows/Rainbird or approved equivalent Make or approved equivalent Make
Providing, installing, testing and commissioning of Maxi Surge Pipe Bermad/Netarim/RainBird/Toro or approved equivalent Make
Providing, installing, testing and commissioning of Maxi Grounding Plate Bermad/Netarim/RainBird/ Toro/Paige or approved equivalent Make
Providing, installing, testing and commissioning of Voltage Stabilizer Make: APC/V Guard/Lumineous or approved equivalent Make
Providing, installing, testing and commissioning of PLB Duct Pipe 32/26mm with pre inserted 3mm nylone rope for cable pulling, length Make: Supreme/Smartflows/Reliance or approved equivalent Make
Filteration Unit
Providing, installing, testing and commissioning of Filter Station Fully Automatic Self Cleaing Filter, Pressure Differential Based, 100/130 Micron, Flanged End & all required Accessories Screen Filter Self Cleaning 50m3 / Hr Make : Rain Bird / Yardeney / Smartflows / VAF or approved equivalent Make
Providing, installing, testing and commissioning of Filter Station Fully Automatic Self Cleaing Filter, Pressure Differential Based, 100/130 Micron, Flanged End & all required Accessories Screen Filter Self Cleaning 25m3 / Hr Make : Rain Bird / Yardeney / Smartflows / VAF or approved equivalent Make
Pump Station
Pump Station Providing, installing and commissioning of Pumping System - Vurticle Multistage Pump having system flow of 37.8 m3/Hr @ 55 Mtr Head (2 Working + 1 SB), combination of 3 Pumps capacity of 18.9 m3/Hr @ 55m Head of each Pumps with All Header, Pressure Tank, Pressure switch, NRV and Butter Fly Valve with VFD Control Panel with all GI C Class Pipes and Fittings (Jindal/TATA/Surya) etc. complete as directed by engineer in charge Make : Grundfos / ITT / Smartflows / Watertronics or approved equivalent Make
Pump Station Providing, installing and commissioning of Pumping System - Vurticle Multistage Pump having system flow of 13.40 m3/Hr @ 45 Mtr Head (1 Working + 1 SB) with All Header, Pressure Tank, Pressure switch, NRV and Butter Fly Valve with VFD Control Panel with all GI C Class Pipes and Fittings (Jindal/TATA/Surya) etc. complete as directed by engineer in charge Make : Grundfos / ITT / Smartflows / Watertronics or approved equivalent Make
Providing, installing and commissioning of Surge anticipation cum Quick Pressure relief Valve 2" Make : Bermad/Rainbird/ Cal-Valve or approved equivalent Make
Providing, installing and commissioning of DWC SN 8 Pipe 6" - Road Sleeve Make : Supreme/Duraline/Astral/Smartflows or approved equivalent Make
Operation & Maintenance of Irrigation System Daily Operation of Irrigation System by using Automation, Routine Check up of Pump Station, Cleaning of Screen Filter, Cehcking Cable Connection, Valves & Servicing them as per requirement. Attending minor repair works as & when required. Maintaining Daily Log sheet provided.
1st year
2nd year
3rd year
4th year
5th year
TOTAL OF PART-II-H : Landscape Irrigation System Work
PART-II-I : Swimming Pool Works
FILTRATION EQUIPMENT Providing/Suppling, instaling, fixing, connecting, testing totally anti-corrosive Bobbin Wound filter, of 900mm diameter Side mount filter with connection of 2"/2½", fitted with pressure gauge panel, manual air bleeder, water drain and emptying plug. Filtration velocity 50m³/hr/m². Max. working pressure : 2.5 kg/cm². Flow rate = 30m³/hr. Fitted with 1” arm collectors and easy-to remove cone diffuser and Transparent top lid with V-clamp system. Working temperature range upto 50ºC. The scope includes supply and installation of filter midia supplied by fiter manufacturer complete as required as per instructions of EIC. (Make: Astral Pool / Certikin) or approved equivalent Make
Providing/Suppling, instaling, fixing, connecting to filter and testing of Side mounted Manual multiport valves with six channels to carry out different functions in an hydraulic circuit suitable to connect to filter connection of 2"/2½". Its design, basically functional, offers a wide range of possibilities of connection to any installation, assuring perfect water-tightness and comfortable handling. complete as required as per instructions of EIC. (Make: Astral Pool / Certikin) or approved equivalent Make
Providing/Suppling, instaling, fixing, PVC 3 Piece Union 2" connecting to filter and Multiport valve and piping, including testing complete as required as per instructions of EIC. (Make: Astral Pool / Certikin) or approved equivalent Make
FILTER FEED PUMP Design, supply, installation, testing at manufacturers works & commissioning of Swimming pool Filteration Feed Pump. Pump body and support in heat-resistant plastic. Double-protected shaft with IP- 55 protection. Large capacity strainer. Noryl Impeller, self priming, suitable to deliver 34 cu.m per hour at 10m Head, complete with common base frame, vibration isolator Neoprene rubber pads air cock, air vent, etc. the motor shall be of suitable 3 H.P for operation at S Phase. the scope shall includes all the items and accessories required to put Pump into service duly tested and commissioned as required and as per instructions of EIC. (Make: Astral Pool / Certikin) or approved equivalent Make
DOSING EQUIPMENT (ph & Chlorine Dosing) Supply, installation, testing, & commissioning of Class On-Off dosing pump. Constant flow membrane dosing pumps whose flow can be manually regulated using a potentiometer that determines the frequency of injections. Regulation range of 0-100% and 0-20%. dosing pump of capacity 20 L/hr @ 3 bar, suitable for mounting on base as well as on wall with suitable MS supports, complete with antiacid plastic case and operating panal protection cover. The pump motor shall be of suitable H.P for operation at 240 V, single Phase, 50 HZ supply. Scope of work includes the tube and necessary foot valve and prefilters etc all require to make the system funcltional, complete as required as per instructions of EIC. (Make: Astral Pool / Certikin) or approved equivalent Make
Supplying, instaling, fixing and connecting Semi transparent polyethelene tank of capacity (minimum) 500 litres with water inlet, drain, outlet, overflow piping, necessory valves & external scale for water/chemical level checking. Tank design should facilitate mounting of dosing pumps on it. The scope includes supply of agitators/stirrer with stearing grip, rod, propeller arm in PE, suitable for mounting in tank as required and as per the instructions of EIC (Make: Astral Pool / Certikin) or approved equivalent Make
Supply, installation, testing & commissioning Ozone Generating Equipment of Approved make producing 100gm/hr. with Feed gas preparation system as per requirement, water chilling system as per requirement, suitable booster pumps, NRV, Injectors, piping etc. The system with controls for ozone output and oxygen feed flow, with indicators for power on, Blown fuse (control & power), ozone output, with protection and interlocks for high/low voltage,control supply fuse,HT supply MCB, high overload. The scope of work includes supply and installation of suitable eqipment and accembly to produce/generate Oxygen from atmospheric air and mixing & piping arrangement. complete as required as per Specifications and instructions of EIC (Make: Astral Pool / Certikin / ORIPAL / AMOZONICS ) or approved equivalent Make
POOL BASIN ITEMS Providing, fixing, laying, jointing & testing following fixtures required as swimming pool accessories as per the drawing, specifications and directed by EIC etc. complete. (Make: Astral Pool / Certikin) or approved equivalent Make
Floor Inlet. Adjustable flow rate. Made of ABS plastic and screws in stainless steel. Maximum recommended flow rate : 12 m3/h
Suction Nozzle. Outer 2" thread, Ø 50 mm inner wall.. Made of white ABS with 11/2" threaded plug.
Wall conduit with 2" rear male thread and Ø 50 mm smooth inner wall. 2" front female thread nozzles with 2" male thread
Drain grille in stainless steel-AISI-304. 300mm x 300mm. Flow Rate: 43 m3/h
Swimming pool Overflow Chanel / Gutter Gratings made in white, U.V. Stabilized PP. 24X300mm
"MIXED" model stainless steel AISI-304 ladders, width: 500mm, handrails dia 43mm stainless steel non-slip steps, provided with electrical earthing connection and anchoring fixtures. No. of treads - 4
Supplying of Lifeguard Chair Made in Stainless Steel AISI-304. With Steps, Platform, Chair, made of Plastic.
CONTROL & REGULATORY VALVES Providing and Fixing uPVC Ball valve/ Butterfly valve / Check Valve (white, offwhite or greay colour suitable and copatible with swimming pool pipes) of Approved make suitable for pipe pressure class of approved make with material and labour, making water proof joints, including cost of jointing material and specials if required & testing the joints. etc complete as per directions of engineer-in-charge.
Ball Valve (2.5" - Pump suction & discharge)
Ball Valve 2" (Filter Inlet, Backwash & Outlet, Pump Suction)
BF Valve 6" (Drain to Balancing Tank)
Check Valve 2.5"(Pump discharge)
Check Valve 4" (Header)
POOL CLEANING SYSTEM Providing / supplying, fixing, laying, jointing & testing following cleaning equipment required as swimming pool cleaning accessories as per the drawing, specifications and directed by EIC etc. complete. Includes making system functional. (Make: Astral Pool / Certikin) or approved equivalent Make
SS Trolley with starter and cable
Cartridge Filter system
Victoria Plus Silent Pump 3HP - S. Phase
Anodised aluminium Vac -Head 350mm - Clip connection
Telescopic Pole 3M X 3 pieces
Vacuum Hose 38mm- 1.5" 30m
Surface net made in polypropelene and
Deep Bag Leaf Net - Shark Series
Curved Brush - Shark Series
Straight brushes made in polypropelene
5" Steel Algae Brush - Graphite
Supply & demonstration of Water Test Kit suitable for, Free Chlorine Total Chlorine Ozone pH Alkalinity Calcium Hardness Copper Cyanuric Acid
Providing, fixing, laying, jointing & testing below the ground / above ground UPVC socketed pipes for solvent cement joint / plain ended CLASS 5 pipes as per IS 4985 ( Agri pipe) including suitable heavy fittings like elbows, collars, tees, unions, couplings, reducers, bends, enlargers, flanged tailpieces and all other fittings required for the completion' laying and jointing as per IS 7634, testing pipelines with fittings for 10 kg/cm2 hydrostatic pressure for minimum duration of two hours with clean water and rectifying the leaks if found, cutting the pipes to the size, threading as required, jointing of pipes and fittings to be carried out using Hold-ties, Teflon tape, PVC clamps, wooden gutties, SS screws, cement, solvent cement etc. required for the completion of the work and all as per specifications, drawings and direction of the Engineer-in-charge.
Nominal OD 63mm
Nominal OD 90mm
Nominal OD 110mm
Nominal OD 160mm
Nominal OD 200mm
Nominal OD 280mm
UNDER WATER LIGHT FITTINGS Supply,installation,testing & commissioning of 12VAC, 28 W LED flat cool white (5700K), 2750 lumen underwater light fitting, IP 68 having white ABS face plate, suitable surface mounted housing the fitting, 2.5/3 m long EPR or silicon rubber insulated copper flexible cable of size 2C X 2.5 sq.mm. The scope also includes ABS body connection box with cover and threaded outlets complete with flexible PVC conduit of suitable length having threaded ends to fix in connection box at one end and light fitting at other end, sockets etc. including all connectors accessories complete as required as per drawing & as per instructions of E-I-C.
Transformer Housing for Underwater light Light fittings: 220V/12VAC, 300 VA transformer suitable for underwater light, 6A DP MCB , interconnections of MCB with transformers, all mounted in weather proof 14 SWG CRCA powder coated enclosure all required as per specifications & as per instruction of E-I-C.
ELECTRIC CONTROL PANEL Supply, Installation, testing & Commissioning of Standard Relay based non-compartmentalised Electric Control panel with Switchgear and internal Panel cabling for Swimming Pool Pump on/off & power supply to Underwater light
SUMP PUMP Supplying of Submersible type non-clog Sump pump in the filtration area for the backwash water drain out Flow: 30 cu. m. /hr @ 1 bar
TOTAL OF PART-II-I : Swimming Pool Works
Description of Work / Item(s)
Amount
ABSTRACT FOR PART - III : ELECTRICAL WORKS
PART - III-A : TTA PANEL
PART - III-B : NON TTA PANEL
PART - III-C : FEEDER PILLAR
PART - III-D : LT CABLES
PART - III-E : LT CABLE END JOINTS
PART - III-F : READYMADE DISTRIBUTION BOARDS
PART - III-G : POINT WIRING
PART - III-H : LUMINAIRES
PART - III-I : LIGHTNING PROTECTION
PART - III-J : EARTHING
PART - III-K : FA
PART - III-L : LAN SYSTEM
PART - III-M : UPS
PART - III-N : HT PANEL
PART - III-O : HT CABLE & END TERMINATION
PART - III-P : ONAN TRANSFORMERS
PART - III-Q : DRY TYPE TRANSFORMERS
PART - III-R : BUS DUCT
PART - III-S : DG SET
PART - III-T : ROOF TOP SOLAR
PART - III-U : LIFTS
PART - III-V : MISCELLANEOUS
Description of Work / Item(s)
Amount
PART III-A - TTA Panel
TTA PANEL: Design, manufacture,shop testing at works, supply, installation, testing & commissioning of floor mounting front operated front/ rear access, extensible type, complete design verified LT Switchgear Panel as per IEC 61439 totally enclosed with IP-42 protection, IK 10 rating and form 3b separation, suitable for use at 415 V, 3 phase 4 wire 50 Hz system, and to withstand a fault level as specified in SOQ. All switchboards shall have provision for entry of cables from the top/bottom as required. The powder coating colour shade for LT Panels shall be as follows:- 1. Panels fed from normal power supply - RAL 7035 2. Panels fed from DG power supply - (Emergency) other shade as per instructions of EIC.
11) Scope includes the cutting of M.S.chequered plate trench covers to required size after installation of Panel. Additional Notes for Substation Panels: 1.Control transformer of 415/240/110V, 1 kVA shall be provided, for suppyling control AC power to Panel equipments and indications. 2.Panels shall have 2 nos. 110V DC bus fed from 2 nos. battery bank through DCDB & with changeover facility. The battery bank & DCDB is measured seperately under item no. xxxx of Section - xxxx 3.All ACBs shall be provided with microprocessor based LSIG protection release. 4.The ACB's to be provided in Panel shall cater to following general specifications : 3 pole/4 pole as specified, 415V EDO type air circuit breaker with breaking capacity of 65/ 50/35 kA at 415V as specified in the respective item description. i) Shunt trip coil suitable for operation on 110 V DC ii) Spring charging mechanism with motor suitable for operation on 240 volts A.C. and with manual spring charging facility. iii) Closing coil suitable for 110 V DC iv) Circuit breaker moving carriage. Carriage will be drawn sequence locking type switch). out horizontally. v) T-N-C switch for electrical operation (ODS type, spring return vi) Mechanical trip knob for actuation in emergency.
Bus Coupler: 1no. 4000A FP EDO ACB with microprocessor based releases, ON-OFF-TRIP indication(All I/C shall be inter connected through bus coupler through electrical & mechanical interlock) Bus bar :4000 A TPN Al bus bar to withstand symmetrical fault level of 65 kA at 415 V. The neutral bus bar shall have 100% capacity. Outgoings :-1 no. 2500A FP, 65kA EDO ACB complete with microprocessor release having over current & short circuit protection 7 noS. 1250A FP, 65kA EDO ACB complete with thermal magnetic release having over current & short circuit protection 2 nos. 800A FP, 65kA EDO ACB complete with thermal magnetic release having over current & short circuit protection 5 nos. 630A FP, 65kA MCCB complete with thermal magnetic release having over current & short circuit protection 1 nos. 400A FP, 65kA MCCB complete with thermal magnetic release having over current & short protection circuit
2 no. 250A FP, 65kA MCCB complete with thermal magnetic release having over current & short circuit 3 no. 125A FP, 65kA MCCB complete with thermal magnetic release having over current & short circuit PLC: PLC shall be suitable for Auto load sensing, controlling, breaker switching sequence and interlock of outgoing breakers of DG synchronization panel, incomers of LT panel after DG synchronization as per specification and instruction of EIC. The preparation of control logic, PLC I/O list, ladder diagram etc and getting approved by EIC is included in the scope of work.
4 nos. 80A FP, 50kA MCCBs complete with star/delta starter 1 no. 63A FP, 50kA MCCB complete with thermal magnetic release having over current & short circuit protection 1 no. 40A FP, 50kA MCCB complete with thermal magnetic release having over current & short circuit protection 6 nos. 25A FP, 50kA MCCB complete with thermal magnetic release having over current & short circuit protection 4 nos. 40A FP, 50kA MCCB complete with star/delta starter for 10 kW motor load
Outgoings : 2 nos. 800A FP, 35kA EDO ACB complete with thermal magnetic release having over current & short circuit protection 2 nos. 630A FP, 35kA MCCB complete with thermal magnetic release having over current & short circuit protection 5 nos. 400A FP, 35kA MCCB complete with thermal magnetic release having over current & short circuit protection 1 nos. 200A FP, 35kA MCCB complete with thermal magnetic release having over current & short 1 nos. 25A FP, 35kA MCCB complete with thermal magnetic release having over current & short circuit protection
Bus bar :1250 A TPN Al bus bar to withstand symmetrical fault level of 50 kA at 415 V. The neutral bus bar shall have 100% capacity. Outgoings :-2 nos. 800A FP, 50kA EDO ACB complete with microprocessor release having over current & short circuit protection 1 no. 250A FP, 50kA MCCB complete with thermal magnetic release having over current & short circuit protection 1 no. 160A FP, 50kA MCCB complete with thermal magnetic release having over current & short circuit protection 5 nos. 100A FP, 50kA MCCB complete with thermal magnetic release having over current & short circuit protection 1 nos. 63A FP, 50kA MCCB complete with thermal magnetic release having over current & short circuit protection 4 nos. 40A FP, 50kA MCCB complete with thermal magnetic release having over current & short circuit 5 no. 25A FP, 50kA MCCB complete with thermal magnetic release having over current & short circuit
Outgoings :-1 No. 315A FP, 50kA MCCB complete with thermal magnetic release having over current & short circuit protection 2 Nos. 160A FP, 50kA MCCB complete with thermal magnetic release having over current & short circuit protection 2 Nos. 100A FP, 50kA MCCB complete with thermal magnetic release having over current & short circuit protection 2 Nos. 63A FP, 50kA MCCB complete with thermal magnetic release having over current & short circuit protection 4 Nos. 40A FP, 50kA MCCB complete with thermal magnetic release having over current & short circuit protection 2 Nos. 25A FP, 50kA MCCB complete with thermal magnetic release having over current & short circuit protection
2 Nos. 40A FP, 35kA MCCB complete with thermal magnetic release having over current & short circuit protection 2Nos. 25A DP, 35kA MCCB complete with thermal magnetic release having over current & short circuit protection
4 Nos. 40A FP, 35kA MCCB complete with thermal magnetic release having over current & short circuit protection 3 Nos. 25A DP, 35kA MCCB complete with thermal magnetic release having over current & short circuit protection
Total of PART III-A - TTA Panel
PART III-B - Non TTA Panel
Design, manufacture,supply, installation,testing & commissioning of floor mounting front operated front access extensible type cubicle panel totally enclosed with IP-42 protection with hinged and lockabale doors. Switchboards fabricated from 2 mm thick CRCA sheets including interconnections,tinned copper strip /Wire crimping lugs, bonding to earth suitable for use at 415 V, 3 phase 4 wire 50 Hz system, and to withstand a fault level of 35/25kA for 1sec or as specified, symmetrical at 415 V complete as per specifications, as required & as below. All switchboards shall have provision for entry of cables from the top/bottom as required. All live accessible parts shall be shrouded and all equipment shall be finger touch proof. The bus bars shall be insulated with heat shrinkable sleeves & color coaded. SMC/DMC shrouds and busbar supports shall be used. Please refer notes for further specifications.
6) All non current carrying metallic parts of the equipment shall be earthed with copper flexible wire / strip of adequate size. 7) All concealed hinged doors and covers shall be provided with suitable flexible earthing connections. 8) The size of the earth bus chosen shall be to withstand full fault current of 35/25kA for 1 sec, asspecified at 415V. 9) Earth bus bar shall be supported at suitable intervals. 10) All the current transformers are resin cast type class-1 only. 11) Scope includes cable end boxes, reverse entry boxes as per site conditions and extension of busbars as required for terminating the number of cables as per schematic diagram. 12) G.A. & detailed fabrication drawing and short circuit forces and temp rise calculation for panel including the panel fabricator shall be submitted for dept. approval. 13) Bimetallic washers to be used for all aluminium to copper joints wherever required & it shall be of approved make & quality whereever required.
14) Indication lamp shall be cluster heavy duty type LED. 15) All Outgoing feeders shall have 'ON', 'OFF', 'Autotrip'. 16) All neutral shall be isolatable type. 17) All inter connection for incoming & outgoing should be with suitable size extension link and insulated copper flexible wire for less than 100A current carrying member. 18) Vertical bus rating shall be based on outgoing feeders. 20) Cubicle illumination lamp & space heater in the cable alley should be provided 21) Scope includes the cutting of M.S.chequered plate trench covers to require size after installation of Panel.
Additional Notes for DG Sync Panels: 1.Control transformer of 415/240/110V, 1 kVA shall be provided, for suppyling control AC power to Panel equipments and indications. 2.Panels shall have 2 nos. 110V DC bus fed from 2 nos. battery bank through DCDB & with changeover facility. The battery bank & DCDB is measured seperately under item no. xxxx of Section - xxxx 3.All ACBs shall be provided with microprocessor based LSIG protection release. 4.The ACB's to be provided in Panel shall cater to following general specifications : 3 pole/4 pole as specified, 415V EDO type air circuit breaker with breaking capacity of 65/ 50/35 kA at 415V as specified in the respective item description. i) Shunt trip coil suitable for operation on 110 V DC ii) Spring charging mechanism with motor suitable for operation on 240 volts A.C. and with manual spring charging facility. iii) Closing coil suitable for 110 V DC iv) Circuit breaker moving carriage. Carriage will be drawn sequence locking type switch). out horizontally. v) T-N-C switch for electrical operation (ODS type, spring return vi) Mechanical trip knob for actuation in emergency.
6.1) 1250 / 5, Class 5P 10 ,15VA resin cast CT. 6.2) 1250 / 5, Class- 1.0 , 15VA resin cast CT. 7) Potential transformer : 7.1) 1 no. ( 415 / sq.rt 3) / (110 / sq.rt 3), 50 VA resin cast PT 8) Push button & switches : 1 Lot 9) Cluster LED indication lamps :1 Lot 10) 12 window Annunciation panel - 1no. 11) Hooter - 1 no. 12) Necessary MCB’s for supply to canopy lighting, battery charger etc. 13) Necessary HRC fuses for control supply etc. 14) Synchronisation through DG controller or separate synchronising relay as per OEM standard and with HMI 15) Protections like U/V, O/V, U/F, O/F, reverse power, field failure through DG controller or separate relay. Busbars: 2500A TPN tinned copper busbar having maximum current density of 1.24 A/sq.mm to with stand symmetrical fault level of 50 KA at 415 V. The neutral busbar shall have100% capacity. Outgoing Feeders: 4P, 415V, 2500A, 50kA ACB as per description at sr. no.14 of notes - 3 nos. Each feeder shall comprise of the following:
Notes: 1) The contractor/ DG manufacturer shall make complete protection curves and discrimination chart for relay/ release and engine controller protection settings and shall adjust all these readings at site. 2) The contractor/DG Manufacturer shall submit ladder diagram of PLC for approval. The components which are not indicated above, but are required for the functioning & for safety of Synchronising Panel shall be included in the scope of work without extra financial implication.
Outgoings: i) 3 Nos. 200 A, 50 kA TP MCCB with tinned Cu neutral link & complete with microprocessor based over current & short circuit release and each including following: a) 3P 95A capacitor duty contactor - 2nos. b) ON/OFF LED type indicating lamps - 2sets c) 7% detuned reactors with Cu windings d) 480V, 100 kVAr (adjusted capacity at bus level) hermetically sealed metallized polypropylene capacitor units MPP-H complete with fuse protection, discharge resistors, interconnections etc complete as required - 1 no. e) ON/OFF push button for manual operation of capacitor unit - 1 set. ii) 4 nos. 100 A, 50 kA TP MCCB with tinned Cu neutral link & complete with microprocessor based over current & short circuit release and each including following: a) 3P 95A capacitor duty contactor - 2nos. b) ON/OFF LED type indicating lamps - 2sets c) 7% detuned reactors with Cu windings d) 480V, 50 kVAr (adjusted capacity at bus level) hermetically sealed metallized polypropylene capacitor units MPP-H complete with fuse protection, discharge resistors, interconnections
etc complete as required - 1 no. e) ON/OFF push button for manual operation of capacitor unit - 1 set. iii) 4 nos. 63 A, 50 kA TP MCCB with tinned Cu neutral link & complete with microprocessor based over current & short circuit release and each including following: a) 3P 95A capacitor duty contactor - 2nos. b) ON/OFF LED type indicating lamps - 2sets c) 7% detuned reactors with Cu windings d) 480V, 25 kVAr (adjusted capacity at bus level) hermetically sealed metallized polypropylene capacitor units MPP-H complete with fuse protection, discharge resistors, interconnections etc complete as required - 1 no. e) ON/OFF push button for manual operation of capacitor unit - 1 set.
iv)1 no. 200A FP, 50kA MCCB complete with thermal magnetic release having over current & short circuit protection v) 1 no. 100A FP, 50kA MCCB complete with thermal magnetic release having over current & short circuit protection vi)1 nos. 63A FP, 50kA MCCB complete with thermal magnetic release having over current & short circuit protection
Outgoings: i) 1 No. 200 A, 50 kA TP MCCB with tinned Cu neutral link & complete with microprocessor based over current & short circuit release and each including following: a) 3P 95A capacitor duty contactor - 2nos. b) ON/OFF LED type indicating lamps - 2sets c) 7% detuned reactors with Cu windings d) 480V, 100 kVAr (adjusted capacity at bus level) hermetically sealed metallized polypropylene capacitor units MPP-H complete with fuse protection, discharge resistors, interconnections etc complete as required - 1 no. e) ON/OFF push button for manual operation of capacitor unit - 1 set. ii) 1 no. 100 A, 50 kA TP MCCB with tinned Cu neutral link & complete with microprocessor based over current & short circuit release and each including following: a) 3P 95A capacitor duty contactor - 2nos. b) ON/OFF LED type indicating lamps - 2sets c) 7% detuned reactors with Cu windings d) 480V, 50 kVAr (adjusted capacity at bus level) hermetically sealed metallized polypropylene capacitor units MPP-H complete with fuse protection, discharge resistors, interconnections
etc. complete as required - 1 no. e) ON/OFF push button for manual operation of capacitor unit - 1 set. iii) 2 nos. 63 A, 50 kA TP MCCB with tinned Cu neutral link & complete with microprocessor based over current & short circuit release and each including following: a) 3P 95A capacitor duty contactor - 2nos. b) ON/OFF LED type indicating lamps - 2sets c) 7% detuned reactors with Cu windings d) 480V, 25 kVAr (adjusted capacity at bus level) hermetically sealed metallized polypropylene capacitor units MPP-H complete with fuse protection, discharge resistors, interconnections etc complete as required - 1 no. e) ON/OFF push button for manual operation of capacitor unit - 1 set. iv)1 no. 200A FP, 50kA MCCB complete with thermal magnetic release having over current & short circuit protection v) 1 no. 100A FP, 50kA MCCB complete with thermal magnetic release having over current & short circuit protection vi) 1 no. 63A FP, 50kA MCCB complete with thermal magnetic release having over current & short circuit protection
AMF Panel- 1. Incomer : 2 nos. 800 A, 50 kA, 415 volt 4P EDO ACB each with microprocessor based O/C+S/C+E/F release and Type 1+2 combined lightning current & surge protection device (SPD) complete with enclosure comprising of following: i) Shunt trip coil suitable for operation on 230V AC. ii) Closing coil suitable for operation on 230V AC. iii) Under voltage coil suitable for operation on 230V/415V AC iv) Spring charging mechanism with motor suitable for operation on 415 volts A.C. and with manual spring charging facility v) T-N-C switch for electrical operation (ODS type, spring return sequence locking type switch). vi) R/Y/B LED indication lamps for mains ON. vii) LED indicating lamps for ON/OFF/Auto trip/spring charged/service position. 2. Bus bar : 800 A TPN Al bus bar to withstand symmetrical fault level of 65 kA at 415 V. The neutral bus bar shall have 100% capacity.
3. Outgoing: 1no. 800 A, 50 kA, 415 volt 4P EDO ACB each with microprocessor based O/C+S/C+E/F release and Type 1+2 combined lightning current & surge protection device (SPD) complete with enclosure comprising of following: i) Shunt trip coil suitable for operation on 110V DC. ii) Closing coil suitable for operation on 110V DC. iii) Under voltage coil suitable for operation on 230V/415V AC iv) Spring charging mechanism with motor suitable for operation on 415 volts A.C. and with manual spring charging facility v) T-N-C switch for electrical operation (ODS type, spring return sequence locking type switch). vi) R/Y/B LED indication lamps for mains ON. vii) LED indicating lamps for ON/OFF/Auto trip/spring charged/service position. 4. Microprocessor based AMF controller comprising of, but not limited to following: 4.1 Mains supply failure monitor (voltage sensor). 4.2 Supply failure timer. 4.3 Restoration timer. 4.4 Control unit incorporating 3 impulse automatic engine start/stop & failure to start lockout.
8.1 RYB – Mains ON with fuse 8.2 RYB- DG Set ON with fuse 8.3 Load on Mains 8.4 Load on DG Set 8.5 DG Set on Test mode 8.6 Trip circuit healthy 9) Annunciation panel (24 V D C) shall be provided with following indications. 9.1 Engine fails to start 9.2 High water temperature. 9.3 Low lub oil pressure. 9.4 Engine over speed. 9.5 Generator under voltage. 9.6 Generator over voltage. 9.7 Generator under frequency. 9.8 Generator over frequency. 9.11 Battery Charger fail. 9.12 Canopy temperature high. 10) Hooter (24 V D C), auxiliary contactors, relays, indicating lamps, MCB’s, fuse etc. as required shall be provided. 11) Necessary auxiliary contactors for contact multiplication.
12) Necessary MCB’s for supply to canopy lighting, battery charger etc. 13) Necessary 2A, HRC fuses for control supply etc. The components which are not indicated above, but are required for the functioning & for safety of AMF Panel shall be included in the scope of work without extra financial implication. 14) Battery charging arrangement with trickle & boost mode, DC ammeter & Voltmeter etc. – 1 nos. to be tapped from load side (O/G) through controlling 32 A TP MCB. (for DG set starting batteries) Notes: 1 Following tests shall be conducted at site in the presence of the E.I.C. before commissioning. The contractor shall provide all testing equipment, labour and any additional materials/consumables required for the testing. a. Checking the alignment b. Insulation resistance test on alternator, control panel and cabling. c. Checking the AMF operation both on auto and manual mode.
d. Checking the engine safeties for satisfactory operation. e. Checking vibration levels. f. Testing of individual protective devices on engine and alternator and ensuring that the wiring is carried out properly. g. Full load running for 8 hours continuously. All the readings shall be logged to evaluate the fuel consumption, lube oil pressure, water & oil temperature vis-à-vis the electrical load. The load for DG set shall be arranged by contractor including consumables like fuel, lube oil etc. for conducting the test. h. The responsibility of erection, testing and commissioning of the set and the accessories shall rest with the bidder.
250A Onload Changeover switch between Main LT Panel & Station Transformer LT side at Plot-A
ATS Panel (Solenoid based) for Student Housing 1 no. 630A FP Auto Transfer Switch similar to ASCO 7000 series with Group 5 controller with overlapping neutral along with multifunction meter with RS-485 communication facility. The panel shall have the following: i) Undervoltage coil suitable for 415V AC ii) R,Y,B phase indication lamps LED type with fuses
Starter Panel for Fire Booster Pump Design, manufacture, supply ,installation, testing and commissioning of star delta starter control panels suitable for 415V, 3 phase, 4 wire, 50 hz power distribution system . Control panel shall consists of 40A Breaker , contactor, Over load relay and other require components to finish satisfactory work. Control panel should be communicate with pressure switch. Necessasary integration between control panel and pressure switch shall be part of scope. scope shall also include all required accessories for dry run protection & shall prevent the pump from dry running All components in the control panel shall be as per type 2 coordination of respective OEM. (Fire Booster Pump Panel). (Cost of wiring with pressure switches / switching on and switching off the pumps locally and remotely as per the drawing and as per local CFO requirement)
Notes: 1. Each incomer and Outgoing feeder should be capable for protection against Overload, Short Circuit and Phase reversal condition and shall be capable to communicate with BMS. 2. All alarms should be displayed in the controller and BMS. 3. System should be equipped with dry running protection. 4. Indication of all type of faults / on-off status / electrical parameters shall be available on panel and central IBMS monitors. On-off operation for all pumps shall be available on BMS system. 5. For centrifugal main fire pump (diesel driven), auto start facility with battery & battery charger, necessary wiring for automatic start of the water pump on drop of pressure in the hydrant and sprinkler system. 6. Pumping System shall be capable to communicate with BMS . 7. Cost of wiring with pressure switches / switching on and switching off the pumps locally and remotely as per the drawing and as per local CFO requirement
Providing and fixing 80A FP MCCB of 25KA having TM Based release with inbuilt and terminal spreaders in metal enclosure/cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.
Providing and fixing 100A FP MCCB of 25KA having TM Based release with inbuilt and terminal spreaders in metal enclosure/cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.
Total of PART III-B - Non TTA Panel
PART III-C - Feeder Pillar
Feeder Pillar: Design, manufacture, supplying, fixing in position, testing and commissioning of feeder pillar with double door with detachable canopy, front operated, front access, 3mm thick MS CRCA sheet steel enclosed free standing, dust and vermin proof, Feeder Pillars with IP-55 protection with hinged and lockable doors complete with interconnections, copper crimping lugs, brass glands, bonding to earth and painting. Feeder Pillar shall be suitable for use at 415 volts, 3 phase 4 wire 50 Hz system, and with 25 KA short circuit capacity at 415 volts. All live accessible parts shall be shrouded and all equipment shall be finger touch proof. The busbar insulation shall be with heat shrinkable sleeves. SMC/DMC shrouds and busbar supports shall be used. Padlocking facility shall be provided. Scope includes suitable angle iron frame work for mounting arrangement 600 mm above ground level necessary grouting, PCC base etc. Also scope incudes enclosing the supports by 3 mm thick MS CRCA sheet steel all around with detachable covers, etc all as per specification and instructions of E-I-C.
Total of PART III-C - Feeder Pillar
PART III-D - LT Cables
L.T Cables: Supply, installation, testing & commissioning of 1.1 kV grade stranded circular/ sector shape core conductor with XLPE insulation, extruded PVC inner sheathed, G.I flat strip/wire armoured, extruded FRLS grade antirodent & anti termite PVC (ST-2) outer sheathed cable conforming to IS 7098 Part-I with latest amendments, fixed on wall/column/ slab/false ceiling or in existing hume pipe/trench/ shaft/pit/ on 5mm thick M.S. flat /GI spacer/angle/ support fixed with coach screws/grouted in wall/anchor fasteners 2mm. thick G.I. fabricated saddle, all fixing accessories, etc complete including painting of M.S. spacers/angles and saddles or in ground at a - depth of 900 mm below ground level , providing brass cable number tag as per enclosed detailed specifications, drawings & as per instructions of the E-I-C & of the following sizes. Notes: 1) Sealing of hume pipes with wooden bushes after cable laying shall be included in the scope of work. 3) Clamping of cables on trays including supply of clamping materials as per instruction of EIC shall be included in the scope of work. 4) Excavation in ground shall be measured separately under relevant item.
3.5C x 300 sq.mm Al conductor armoured cable
3.5C x 240 sq.mm Al conductor armoured cable
3.5C x 185 sq.mm Al conductor armoured cable
3.5C x 150 sq.mm Al conductor armoured cable
3.5C x 120 sq.mm Al conductor armoured cable
3.5C x 95 sq.mm Al conductor armoured cable
3.5C x 70 sq.mm Al conductor armoured cable
3.5C x 50 sq.mm Al conductor armoured cable
3.5C x 35 sq.mm Al conductor armoured cable
4C x 25 sq.mm Al conductor armoured cable
4C x 16 sq.mm Cu conductor armoured cable
4C x 10 sq.mm Cu conductor armoured cable
4C x 6 sq.mm Cu conductor armoured cable
4C x 4 sq.mm Cu conductor armoured cable
4C x 2.5 sq.mm Cu conductor armoured cable
3C x 16 sq.mm Cu conductor armoured cable
3C x 10 sq.mm Cu conductor armoured cable
3C x 6 sq.mm Cu conductor armoured cable
3C x 4 sq.mm Cu conductor armoured cable
3C x 2.5 sq.mm Cu conductor armoured cable
3C x 2.5 sq.mm Cu conductor flexible cable
3C x 4 sq.mm Cu conductor flexible cable
2C x 4 sq.mm Cu conductor flexible cable
1C x 240 Sq.mm. CU XLPE flexible cable
Total of PART III-D - LT Cables
PART III-E - LT Cable End joints
LT CABLE END TERMINATIONS LT Cables End Joints End jointing of following sizes of cable by crimping with supply of all jointing materials like solderless aluminium lugs, double compression brass cable glands, gland earthing, insulation tape, flux, duplicate interconnection between gland earthing strip & to the nearest earthing bus terminals as per the drawings, specifications and as per the instructions of the Engineer-in-charge.
3.5C x 300 sq.mm Al conductor armoured cable
3.5C x 240 sq.mm Al conductor armoured cable
3.5C x 185 sq.mm Al conductor armoured cable
3.5C x 150 sq.mm Al conductor armoured cable
3.5C x 120 sq.mm Al conductor armoured cable
3.5C x 95 sq.mm Al conductor armoured cable
3.5C x 70 sq.mm Al conductor armoured cable
3.5C x 50 sq.mm Al conductor armoured cable
3.5C x 35 sq.mm Al conductor armoured cable
4C x 25 sq.mm Al conductor armoured cable
1C x 240 Sq.mm. CU XLPE flexible cable
LT Cables End Joints End jointing of following sizes of cable by crimping with supply of all jointing materials like solderless tinned copper cable socket, copper lugs, double compression brass cable glands, gland earthing, insulation tape, flux, duplicate interconnection between gland earthing strip & to the nearest earthing bus terminals as per the drawings, specifications and as per the instructions of the Engineer-in-charge.
3/4C x 16 sq.mm Cu conductor cable
3/4C x 10 sq.mm Cu coductor armoured cable
3/4C x 6 sq.mm Cu conductor cable
3/4C x 4 sq.mm Cu coductor cable
3/4C x 2.5 sq.mm Cu coductor armoured cable
2C x 4 sq.mm Cu conductor flexible cable
Supplying and making straight through joint with cast resin compound including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3.5C X 240 sq.mm
Supplying and making straight through joint with cast resin compound including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3.5C X 300 sq.mm
Total of PART III-E - LT Cable End joints
PART III-F - Readymade Distribution Boards
READYMADE DISTRIBUTION BOARDS: Supply, installation, testing & commissioning of following readymade distribution boards, double door, IP 42 degree protection complete with necessary, MCB isolators , MCBs, earth leakage circuit breaker (ELCB) etc including interconnections with appropriate capacity size of PVC insulated copper conductor wires (ISI marked), suitable for concealed mounting /wall mounting with MS frame work of 40 x 40 x 5 mm MS angle iron, with M.S. enclosure fabricated of M.S. CRCA sheet as per manufacturers standard, with sheet as per manufacturers standard, with concealed hinged door, locking arrangement etc. including earthing clamps for both incoming & outgoing circuits, interconnections, per phase isolation kit as required,cable end box & wire way box if required, continuous copper earth wire in the wire way box with single/duplicate brass earthing terminals, danger board, name plate, flexible earthing for the door, metal treatment & powder coated painting, Phase Distribution drawing etc. all as per drawings (G.A. & fabrication drawing to be got approved), etc.
Notes: 1. MCCB shall be of 25kA breaking capacity. 1. MCBs (Type –C) shall be minimum 10 kA breaking capacity, as specified. 2. Blanking Plates shall be included in scope of work. 3. DB shall be of standard readymade type as per catalogue No. from approved manufacturers as indicated in preferred makes of material. 4. Routine tests will be conducted at factory as per relevant IS.
SPN DB Type-1 a) 40 A DP 30mA RCBO - 1 No. b) 6 A -32 A SP MCB -- 6 nos C) 8 way brass neutral link -- 2 Sets.
SPN DB Type-2 a) 40 A DP 30mA RCBO - 1 No. b) 6 A -32 A SP MCB -- 4 nos C) 8 way brass neutral link -- 2 Sets.
Horizontal TPN DB Type-1 a) 40 A FP MCB - 1 No. b) 40 A, DP ELCB with 30mA sensitivity- 3Nos. c) 6 A -32 A SP MCB -- 18 nos d) 8 way brass neutral link -- 4 Sets.
Horizontal TPN DB Type-2 a) 40 A FP MCB - 1 No. b) 40 A, DP ELCB with 30mA sensitivity- 3Nos. c) 6 A -32 A SP MCB -- 24 nos d) 8 way brass neutral link -- 4 Sets.
Horizontal TPN DB Type-3 a) 40 A FP MCB - 1 No. b) 40 A, DP ELCB with 30mA sensitivity- 3Nos. c) 6 A -32 A SP MCB -- 36 nos d) 8 way brass neutral link -- 4 Sets.
VTPN DB Type-1 a) 63 A FP MCCB - 1 No. b) 6A-32A TP MCB - 8 Nos.
VTPN DB Type-2 a) 100 A FP MCCB - 1 No. b) 40A TP MCB - 8 Nos.
VTPN DB Type-3 a) 100 A FP MCCB - 1 No. b) 6A-32A TP MCB - 4 Nos. c) 6A-32A SP MCB - 12 Nos.
VTPN DB Type-4 a) 63 A FP MCCB - 1 No. b) 6A-32A TP MCB - 7 Nos. c) 6A-32A SP MCB - 15 Nos.
VTPN DB Type-6 a) 100 A FP MCCB - 1 No. b) 6A-32A TP MCB - 8 Nos.
VTPN DB Type-7 a) 125 A FP MCCB - 1 No. b) 6A-32A TP MCB - 10 Nos. c) 6A-32A SP MCB - 6 Nos.
VTPN DB Type-5 a) 40 A FP MCCB - 1 No. b) 6A-32A TP MCB - 4 Nos.
VTPN DB Type-8 a) 63 A FP MCCB - 1 No. b) 6A-32A TP MCB - 12 Nos.
Flexi-DB with acrylic door : a) 40 A FP MCB type Isolator -- 1 No. b) 40A, 4 NO Power contactor -- 1 no c) Auxiliary changeover switch for 40A contactor--1 No. d) Digital time switch with one channel - 1 No. e) 25A FP MCB (D-Curve) -- 3 nos. f) 8 way brass neutral link -- 4 sets
Supply, installation, testing & commissioning of 63 A FP RCBO with 300mA sensitivity in a readymade powder coated MS CRCA wall mounted enclosure with MS cover and with necessary cutouts, interconnections earthing stud etc. (in Machine Room for Lift machines)
Supply, installation, testing & commissioning of 16 A DP RCBO with 30mA sensitivity in a readymade powder coated MS CRCA wall mounted enclosure with MS cover and with necessary cutouts, interconnections earthing stud etc. (Shaft lighting)
Supply, installation, testing & commissioning of 6 A DP RCBO with 30mA sensitivity in a readymade powder coated MS CRCA wall mounted enclosure with MS cover and with necessary cutouts, interconnections earthing stud etc.(for Car lighting)
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.
100A 50kA TP MCCB
630A 50kA TP MCCB
Weather Proof Isolators & Sockets Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32 A 240 V "C" curve DP MCB complete with connections, testing and commissioning etc. as required.
Supplying and fixing TP sheet steel enclosure on surface/ recess along with 16/25/32 A 415 V "C" curve TP MCB complete with connections, testing and commissioning etc. as required.
Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top along with 20 A "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
Supplying and fixing 32 A, 415 V, TPN Industrial type socket outlet, with 4 pole and earth, metal enclosed plug top along with 32 A "C" curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
Supplying and fixing FP sheet steel enclosure on surface/ recess along with 40 A ,415 V ELCB 100mA, complete with connections, testing and commissioning etc. as required.
Supplying and fixing FP sheet steel enclosure on surface/ recess along with 63 A ,415 V ELCB 100mA, complete with connections, testing and commissioning etc. as required.
Supplying and fixing 125 A, 415 V, TPN Industrial type socket outlet, with 4 pole and earth, metal enclosed plug top along with 32 A "C" curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
Total of PART III-F - Readymade Distribution Boards
PART III-G - Point Wiring
POINT WIRING: Point wiring for light/ceiling fan/6A/ 16A/ socket outlet /6A outlet for exhaust fan , bell point etc. with 1.1 KV grade FRLS PVC insulated multistranded copper conductor wire(ISI marked), in 25 to 40 mm dia High mechanical stress (HMS) rigid PVC conduit having ISI marked IS 9537 Part - 3, including fixing accessories & hardware concealed /exposed in slab/wall or on 5mm. thick G.I. spacers fixed with no. 10 nettle fold wood screws with nylon plug complete with all conduit accessories 20 SWG G.I. Saddles, ready made MS switchboxes & socket outlet boxes of min 18 SWG / 20 SWG thickness , brass earthing stud 1/2 nos, controlling modular switches, sockets with moulded front plate and inner plate etc. including appropriate size of FRLS PVC insulated copper earth wire, brass/bakelite (straight / angular) lamp holders, 3 plate ceiling rose,16 A, connectors, painting etc. as per specifications and drawings and as per instructions of E-I-C and as detailed below : (sample switch Box etc. to be got approved before fabrication). Note:- Modular Plates for Emergency Lighting Switchboards and UPS powered Switch-Socket Power Points & Computer Workstation Points should be considered of Grey Colour.
Wiring for light point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed heavy duty class 25 mm dia PVC conduit, with modular switch, modular plate, suitable Gl box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
Group C
Wiring for light point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed heavy duty class 25 mm dia PVC conduit, with modular switch, modular plate, suitable Gl box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
Group A
MCB Controlled Light Point Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed heavy duty class 25 mm dia PVC conduit, controlled by MCB and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
Group C
Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed heavy duty 25 mm dia PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.
Group A
Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed heavy duty class 25 mm dia PVC conduit, 2 way modular switch, modular plate, suitable Gl box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required.
Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed heavy duty 25 mm dia PVC conduit as required.
2 X 1.5 sq. mm + 1X1.5 sq. mm earth wire
2 X 2.5 sq. mm + 1X2.5 sq. mm earth wire
2 X 4 sq. mm + 1 X 4 sq. mm earth wire
2 X 6 sq. mm + 1 X 6 sq. mm earth wire
Supplying and fixing Seperate 6A Switch-Socket with suitable size Gl box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 6 A modular socket outlet and 6 A modular switch, connections etc. as required.
Supplying and fixing Seperate 6/16A Switch-Socket withsuitable size Gl box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 6 & 16 A modular socket outlet and 16 A modular switch, connections etc. as required.
Supplying and fixing Onboard 6A Switch-Socket with suitable size Gl box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 6 A modular socket outlet and 6 A modular switch, connections etc. as required.
Supplying and fixing Computer Point with suitable size Gl box with modular plate and cover in front on surface or in recess, including providing and fixing 2 nos 3 pin 6 A modular socket outlet control by 1 nos 16 A modular switch & and 6 A modular switch and 6 pin 6 & 16 A modular socket outlet and 16 A modular switch, connections etc. as required.
Supplying & fixing suitable size Gl box with modular plate and cover in fronton surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, "C" curve including connections, painting etc. as required.
Total of PART III-G - Point Wiring
PART III-H - Luminaires
Light Fixtures & Fittings: Supply, installation, testing & commissioning of fixtures & fittings,ceiling fans, exhaust fans,etc complete with accessories, tube/ lamp etc in on surface of slab/ beam by 2 nos (minimum) of 6 mm anchor fasteners or on wall with 2 nos of wood screws, nylon plug etc., provision & connection with 1.5 sq.mm multistranded copper conductor FRLS PVC wires etc., all as per drawing, specifications & as per the instruction of E.I.C. Notes: 1) Sample fixture/fittings shall be got approved from Dept. with complete technical data. 2) The Cat No. indicated below is only indicative. 3) All fixtures shall be with low loss electronic ballast/ drivers. 4) Cost of mounting accessories shall be included in Fixture cost. 5) Final wattage capacity, light fixture colour, light CCT,Fixture sample is to be done and approved by the Engineer incharge after sampling and mock-up before finalization. 6) Luminaire should be Tested Under NABL Accredited lab having LM79/80 and Type test report, BIS Certification.
7) Driver and luminaire shall be of same make. 8) LM79 and LM80 reports must be submitted from a NABL accredited laboratory. BIS certificate for driver as well as the luminaire must be submitted for records. 9)LED used Should be of Reputed makes only such as CREE/Lumiled / NICHIA / OSRAM / SAMSUNG / APT. 10) Heat sink should be designed for better heat dessipation 11) Operating Voltage range of driver should be 150 – 270 VAC. 15) Surge Protection > 2.5Kv for indoor products and > 4Kv for Outdoor products 16) Luminaire must be supplied along with all the accessories such as driver, moutning tracks/ clips, end caps, diffuser, strip connectors etc as applicable.
36 W IP20 LED Batten Light System Lumen(min) 4000. System Efficacy( min) 110 Lm/W, Extruded Al housing with UV Shielding PC diffuser, CCT of 6500 K, IP20 and IK02 Protected.
30 W LED Recess mounted (2X2feet) luminaire, 3600 System Lumen(min), System Efficacy (min) 125 LM/W. CRCA Housing with Glare Free PS Diffuser,IP20 and IK02 Protected. CCT of 6500 K.
9W recessed mounted downlighter polycarbonate diffuser and PDC Al housing 1000 Lumen(min), System Efficacy(min) 110 Lm/w, 4000K / 6500K, IP20 and IK02 protected.
18W LED recessed mounted Downlighter polycarbonate diffuser and PDC Al housing recessed design 150 mm Cutout for visual comfort Downlighter delivering 2000 Lumen(min),System Efficacy(min) 110 Lm/W, 4000K / 6500K, IP20 and IK02 Protected.
40W recessed mounted Downlighter High quality polycarbonate diffuser and PDC Al housing, lumen output (min) 4000 Lumen, 4000K / 6500K, IP20 and IK02 Protected.
9W LED Round Surface mounted downlighter 1000 Lumen(min), System Efficacy (min) 110 LM/W. High-Grade Opaque polycarbonate Housing with moulded high transitivity PC diffuser with IP20 and IK02 Protected, CCT of 6500 K.
10 W LED IP65 Up light suitable for wall mounting, pressure Die cast aluminium housing, proper heat sink designed for better heat dessipation , clear toughned glass diffuser with IK08 protection , Electronic driverpower factor>0.95, THD <15 % Minimum lumen 2000 Lumens in CCT range of 3000/4000/5700
2X10 W IP 65 LED Up light suitable for wall mounting, pressure Die cast aluminium housing, proper heat sink designed for better heat dessipation , clear toughned glass diffuser with IK08 protection. Electronic driver power factor>0.95, THD <15 %. Minimum lumen 2000 Lumens in CCT range of 3000/4000/5700.
22 W Recess Mounted Linear Light with Connected option with system lumen of Min 2200, system efficacy (min) 100Lm/w. White Powder coated Extruded Al housing with Glare free PC diffuser.LED should be of 6500 K.
20 W LED Track Light mounted on Track with LEDs of wattage 0.2 Watt to 0.5 Watt assembled on single MCPCB, with CRCA/ aluminium die cast powder coated housing/ heat sink made of thick Sheet Steel and high U.V. & corrosion resistance with diffuser, THD < 15%,CCT 3000 K to 6500K, Luminaire efficacy> 85 lumens/watt ,LED driver efficiency > 85 % including Track with inbuilt copper bus & other required accessories etc.
36 W Suspended Linear Light with 4000 system lumen (min), system efficacy(min) 110Lm/W, Powder coated (White ) Extruded Al Housing only with Glare free PC diffuser. CCT: 6500 K.
15W LED Wall Mounted Decorative Luminaire, IP20 , with CRCA housing powder coated and high U.V. & corrosion resistance with diffuser and/or Polycarbonate, Luminaireefficacy> 100 lumens/watt.
11 Watts, wall mounted MIRROR LIGHT with housing and LED lamp with > 100 Lumen/watt efficiency as approved by the Engineer.
80W circular ring suspended type Luminaire (1200 MM DIA CIRCULAR RING) diffused Light fixture of Tentative Dimension: Ø=1200mm, H=80mm of approved make suitable for operation at 230V,50Hz complete with housing, cover and LED lamp with > 100 Lumen/watt efficiency, Life : 50000 burning hrs.
60W circular ring suspended type Luminaire (900 MM DIA CIRCULAR RING) diffused Light fixture of Tentative Dimension: Ø=900mm, H=80mm of approved make suitable for operation at 230V,50Hz complete with housing, cover and LED lamp with > 100 Lumen/watt efficiency, Life : 50000 burning hrs.
36W circular ring suspended type Luminaire (400 MM DIA CIRCULAR RING) diffused Light fixture of Tentative Dimension: Ø=400mm, H=80mm of approved make suitable for operation at 230V,50Hz complete with housing, cover and LED lamp with > 100 Lumen/watt efficiency.
STRIP/COVE LIGHT IP20 LED strip including driver with a nominal system lumen output of 800 lm /m with system efficacy of 105lm/W. 30,000 burning hours. CCT: 4000K
12 W Bulk Head light fixture System Wattage: 12W LED, LED Lumens: 500 lm, CRI (Ra): ≥80, LED Colour Temperature: 3000K / 4000K / 5700K, IP66 & IK 09.
3 W LED concealed step light (dimension: 150 x 80 x 70mm.), BIS approved, pressure Die cast aluminium housing, clear toughned glass diffuser, THD <15 %. 700 Lumens(min), CCT range of 3000/4000/5700
12Watts IP-65 Wall bracket light (Outdoor Type) System Wattage: 12W LED, LED Lumens: 500 lm CRI (Ra): ≥80, LED Colour Temperature: 3000K / 4000K / 5700K.
Passive Infrared(PIR) technology based occupancy sensor having high performance, non regulating programmable type, suitable for connected load upto 10Amp , for mounting height up to 2.8 mtr and for 5 m diameter coverage area along with necessary fixing arrangements i/c programming at site etc. complete as required. Note: Scope includes wiring also.
20 W LED surface mounted IP 20 cylindrical light, pressure Die cast aluminium housing, clear toughned glass diffuser with IK08 protection, THD <15 %. 800 Lumens(min) in CCT range of 3000/4000/5700 as per ANSI,life of 50000 burning hours.
Emergency exit sign- illuminated, surface mount (wall or ceiling) Dual sided made up of plastic material , battery backup of 3 hours (180 mins), Li- ion battery, Viewing distance: 30 metre, degree of protection IP20, white light colour full back (white colour) LED illumination with green white coloured graphic inserted on both sides on 0.4 mm PC (sizes, texts, symbols or graphics as per standard safety norms & regulationsand instructions of EIC). Test facilty button self test plus auto self test, opreration in maintained mode. Sign provided with dual mounting arrangement of mounting on wall & celing both ( with flat rigid support/base). Sign includes all connection wires (upto 1 mtr) & high tensile strength zinc coated self tapering screws, installed at site in plumb and level at specified location as per drawing to the satisfaction of the engineer-in-charge.
Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with remote control/regulator with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, with double ball bearing with 26 cm to 100 cm long down rod as per requirement, canopies, shackle kit, safety rope (safety secondary suspension provision), copper winding, Air delivery minimum 230 Cum/Min. with all accessories including continous earthing and final connection with 24/0.2 mm dia copper conductor 2/3 core twisted PVC flexible wire, etc. Note: BLDC fan should be as per technical specifications and testing conforming to IS; 374/79 with latest amendments all as per specifications & instructions of EIC.
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Fan Hook Boxes: Supply, installation, testing of concealed fan hook boxes of size 150 x 150 x 75 mm deep fabricated outof 2mm thick M.S CRCA sheet with nominal 12 mmdia M.S tested rod hook with brass earthing stud & welded nut from inside and 2mm thick round M.Scover plate overlapping by 15 mm, including redoxide and two coats of white synthetic enamel paints and brass chromium plated screws and cupwashers for fixing and all as per conceptional drawing No.: CED/EM /STD/11 R4 & instruction of Engineer-in-charge (Sample box with cover to be got approved before fabrication including the fabricator)
T type Fan hook: Providing Ceiling fan hook fabricated out of 150mm x 150mm x 10mm (Approx.) MS sheet with 12mm MS rod hook wilded on MS sheet, holes on corners & painting with two coat of enamel paint over one coat of red oxide and with four nos. of anchor fasteners 10mm dia ( Approx.), all as required & instruction of Engineer-in-charge (Sample to be got approved)
Fly Kill :Supply, installation, testing & commissioning of UV Fly Catcher Machine (Flying Insect Killer Machine) of 20W Power Consumption, duly suspended from the ceiling with electro-zinc coated TF rods, ceiling mounting brackets etc.
Electrical hand dryer,fully automatic type , cover shall be fabricated in extra heavy duty18 gauge type 304 SS with exposed surfaces satin finished, the unit shall deliver not less than 30 l/sec of hot air and electrical rating shall be 230 V / 1 phase. Make : Jaquar, Model no. PTD-SAP-DT0106CS
Providing and fixing C.P. brass air purifier fixed to wooden cleats with C.P. brass screws complete. Air Purifier: Dolphy , Model No: DAPD0001
Water Heaters: Supply, installation, testing & commissioning of storage type (Horizontal/Vertical mounting) water heater of following capacity to work on 230V AC supply with 2000 W heating element complete with all accessories, ISI mark, BEE min 4star rated with MS polymer/glass rust proof coating inner container and ABS plastic outer body, PUF insulation between inner & outer container, thermostat , thermal cut out, pressure release valve,3 Cx 2.5 sq.mm PVC insulated stranded copperchord for interconnection between water heater to junction box, connector, flexible pipe of suitable size for inlet and outlet water connection etc .Scope includes M.S supports fabricated out of 25mm x 5 mm thick M flat supports fabricated out of 25 mm x 5 mm thick M flat fixed on wall with 4 nos.of No. 10 nettle fold screws in wall with nylon/phil plug & all mounting accessories including connection with suitable lugs, all as per specificaiton and instruction of E-I-C. Note: Sample water heater to be submitted for approval. including all required accessories, etc. complete including cutting and making good the wall where required.
Water Geyser 6 L
Water Geyser 70 L
Water Geyser 100 L
LUMINAIRES TO BE DIMMED DALI dimmable recessed linear LED fixture, 2600 lumen output(min), 120 lm/W . CR>80, CCT 4000K or 6500K, extruded aluminum housing with PS diffuser. PF>0.95, THD<10%, Ripple <5%. Lifetime 50000 hours @ L70B50 at 450C. .
40W DALI dimmable recessed LED downlighter with efficacy (min) 100 lm/W, CRI>80, CCT 4000K/5700K/6500K, 30000 hours @L70B50 Beam angle of 24/36 0, die cast aluminum housing, PF>0.9, THD<10%.
DALI dimmable LED batten with 4000 lumen output(min), efficacy(min) 110 lm/W, extruded aluminum housing and polycarbonate cover, PF > 0.9, THD<10%. CRI>80, CCT4000K/6500K
DALI dimmable LED luminaire recessed accent lighting luminaire with 4000 lumen output(min), efficacy: 100lm/W, CCT: 4000K, die cast aluminum housing and glass cover, beam angle : 36 0
DIMMING & CONTROL SYSTEM Supply, Installation, Testing & Commissioning of LED Luminaire Dimming Control System, real-time, preemptive multi-threaded/multitasking kernel, Transaction-Safe Extended FAT file system; supports up to 10 simultaneously running programs, Ethernet: 100 Mbps, auto‑switching, auto‑negotiating, auto‑discovery, full/half duplex, industry-standard TCP/IP stack, UDP/IP, CIP, DHCP, SSL, TLS, SSH, SFTP (SSH File Transfer Protocol), FIPS 140-2 compliant encryption, IEEE 802.1xX, SNMP, BACnet and IP3, IPv4 or IPv6, Active Directory® service authentication, HTTPS web server, HTTPS web browser setup and Cloud client, SMTP email client, USB, RS-232/ 422/485, IR/ Serial.
Supply, Installation, Testing & Commissioning of PoE Injector, 802.3af compliant Power over Ethernet (PoE) power source designed to support PoE powered devices.
Supply, Installation, Testing & Commissioning of DIN Rail 2-Channel DALI Interface, Interfaces with 2 independent DALI® loops Controls up to 128 DALI ballasts, PoE communication for single-wire installation, Integrated DALI power supply
Supply, Installation, Testing & Commissioning of DIN Rail 60 Watt Power Supply, 60 Watt, DIN rail-mounted power supply module for powering automation processors and other devices.
Supply, Installation, Testing & Commissioning of DIN Rail Distribution Hub, 3-segment hub for with more than 20 devices, Configurable power distribution.
Supply, Installation, Testing & Commissioning of Keypad with Communications, Standard Engraved, Black: keypad that provides network control of lighting, shading, audio, and other amenities. Default engraving on a five pushbutton button assembly.
Supply, Installation, Testing & Commissioning of Backlit Pushbutton, Custom Engraved, Black is a button assembly that consists of three single pushbuttons and two split rocker buttons that includes Custom Engraving.
Supply, Installation, Testing & Commissioning of Control Cable, Non-Plenum, Black, 1000 ft (304 m) box: flexible 4-wire network that provides bidirectional communication and 24VDC power for devices. It allows for both homerun and daisy-chain wiring topologies, with cable lengths up to approximately 3000 feet (915 meters) per run.
Supply, Installation, Testing & Commissioning of Enclosure for DIN Rail Devices, 3 DIN Rails, 18 M Wide, enclosure that provides a centralized mounting solution for DIN rail products.
INSTALLATION DETAILS Supply, Installation, Testing & Commissioning of Power Cable 2.5 Sqmm x 3 core (80/0.20mm) ATC copper Conductor, 1.5 Sqmm x 2 core shielded Cable for Control, and other related cables, accessories and containment for First Floor - Academic Block as required. All drawings, Cable Samples to be installed after approval of AV Consultant.
Supply, Installation, Testing & Commissioning of Power Cable 2.5 Sqmm x 3 core (80/0.20mm) ATC copper Conductor, 1.5 Sqmm x 2 core shielded Cable for Control, and other related cables, accessories and containment for Second Floor - Academic Block as required. All drawings, Cable Samples to be installed after approval of AV Consultant.
EXTERNAL LIGHTING 60W LED Post Top fittings with IP 65 Luminaire efficacy(min) 130 lm/w and corrosion free High pressure die cast aluminum housing with smooth finish powder coated and heat sink extruded aluminium with diffuser and Polycarbonate, CCT : 3000 K to 4000K, Tentative Dimension: Ø=600mm, H=400mm Post Top Lantern LED fitting comprises of Copper dust finish cast aluminum spigot and spun aluminum canopy fixed with opal polycarbonate, pipe arrangement for vertical mounting,open construction driver and accessories wired upto terminal block.
16 W LED IP65 Bollard light fittings luminaire efficacy > 130 lm/w and corrosion free High pressure die cast aluminum housing with smooth finish powder coated and heat sink extruded aluminium with diffuser and Polycarbonate optics/ lenses, CCT 3000 K to 4000K, Tentative Dimension: Ø=165mm, H=900mm LED Bollard of height (min) 900 mm and dia 165 mm, polycarbonate clear/milky diffuser mounted on 3mm thick aluminum finished powder coated pipe with base plate 160x160 mm with erection by M8x75mm fastner with required PCC foundation , water proof 2/3way straight or T-shaped connector, Surge -4KV
12W IP65 LED Step Light with fibre reinforced plastic housing, with housing used as a heat sink, CRCA powder coated and high U.V. & corrosion resistance with diffuser and/or Polycarbonate optics, CCT 3000 K to 4000K, Uniformity ratio >0.7,Luminaire efficacy> 100 lumens/watt ,LED driver efficiency > 85 %, Sample and Colour Temperature of fixture to be approved from EIC. water proof 2/3way straight or T-shaped connector. Tentative Dimension: L=200mm, B=150m
18 Watt bush light led light fixture with housing used as a heat sink shall be made of thick sheet Steel / CRCA polyester powder coated and high U.V. & corrosion resistance with Die cast aluminum, compact, aesthetic, pure polyester,powder coated housing, IP 66, IK 10, optically sealed housing with toughened glass totally, sealed using Silicon gasket ensuring IP and lifelong,performance, CCT 3000 K to 4000K, Luminaire efficicacy> 85 lumens/watt. Tentative Dimension: Ø=80mm, H=120mm
36 W – IP66 LED Batten Light System Lumen(min) of 4000, System Efficacy (min) 110 Lm/w., Extruded Al housing with UV Shielding Acrylic diffuser, CCT of 3500/4000 K.
200W LED Flood light fittings, Luminaire efficicacy >130 lm/w and corrosion free High pressure die cast aluminum housing with smooth finish powder coated and heat sink extruded aluminium with diffuser and Polycarbonate optics/ lenses, with toughened glass, CCT 3000 K to 5700K
Supplying and erecting approved make Circular pole made of MS. The pole Shall be coated zinc rich epoxy primer coating and finished using environmentally stable Polyurethane base paint. , suitable suspend local wind speed with pole sections are welded using special v groove technique by certified welders using high end MIG welding processes with (D) 4.3 Mtr. Long , 100 mm dia throughout, 3 mm thickness with 250mmX250mmX10mm base plate with steel grade E250, 4-M20 Bolts and 600mm long J-Bolt for foundation bolt of grade 4.6 Final finish paint shall be charcoal shade or as per approved by EIC.
45W IP67 Outdoor surface mounted LED linear grazer (OSC1a) made of extruded aluminum, with matte dark grey powder coating finish, 3460lm, luminaire efficacy 77lm/W, IK08 Protection, Integral Switched driver with adjustable tiltable mounting Aluminium bracket and custom anti-glare Aluminium shield, CCT : 3000K (1200mm module) 3460lm, luminaire efficacy 77lm/W, IK08 Protection, Integral Switched driver, Nominal Luminaire dimensions: L: 1200mm, W: 95mm, Luminaire height H: 62mm, Total height: 95mm, F: Dark grey
IP67 Outdoor recessed ground LED uplight (ORG2) with anti-glare louvers and recessing box, CCT : 3000K / As required luminous flux: 855lm, Minimum luminaire efficacy 65lm/W, IK10 Protection corrosion resistant die-cast aluminum Housing. Nominal Luminaire dimensions: Dia:129mm H: 173mm, F: SS
IP20 Recessed LED round downlight (RC1), CCT : 3000K, luminous flux is 370-450lm, luminaire efficacy 85lm/W, Round recessed spotlight, die-cast aluminium housing, Nominal Luminaire dimensions: Dia:48mm, H:80 mm
45W IP67 Outdoor surface LED linear grazer (OSC1b) with aluminium tiltable mounting bracket, CCT : 3000K, luminous flux is 1825lm, luminaire efficacy 76lm/W, IK08 Protection Nominal Luminaire dimensions: L: 600mm, W: 95mm, Luminaire height H: 62mm, Total height: 95mm, F: Dark grey
IP67 Outdoor surface ground 45W LED linear grazer (OSG1a) with adjustable tiltable mounting bracket and custom anti-glare shield, CCT : 3000K (1200mm module) luminous flux is 1825lm, luminaire efficacy (min) 76lm/W, IK08 Protection extruded aluminum housing, matte dark grey powder coating finish. Nominal Luminaire dimensions: L: 1200mm, W: 95mm, Luminaire height H: 62mm, Total height: 95mm, F: Dark grey
IP67 Outdoor surface ground 45W LED linear grazer (OSG1b) with adjustable tiltable mounting bracket and custom anti-glare shield, CCT : 3000K (1200mm module) luminous flux is 1825lm, Minimum luminaire efficacy 76lm/W
IP65 Outdoor surface ceiling LED Wallwasher (OSC2) , CCT : 3000K, lumen output 1560lm, luminaire efficacy (min) 52lm/W, Nominal Luminaire dimensions: Dia: 175mm H: 262mm F: Dark grey/ as per architect and site engineer in-charge
IP67 Outdoor recessed ground LED uplight (ORG1) with anti-glare louvers and recessing box, CCT : 3000K, luminous flux is 3109lm, luminaire efficacy (min) 111lm/W, IK10 Protection, corrosion resistant die-cast aluminum Housing. Nominal Luminaire dimensions: Dia:224mm H: 345mm, F: SS
IP67 Outdoor surface ceiling LED striplight (OSG2) with diffuse cover and mounting profile, CCT : 3000K, luminous flux is 1930-2000lm/m(without diffuser), luminaire efficacy (min) 137lm/W (without diffuser) Nominal Luminaire dimensions: W: 20mm (with mounting profile), H: 20mm (with mounting profile) , F: Standard
IP67 Outdoor recessed ground asymmetric wall washer (ORG3) optic LED uplight with antiglare louvers & recessing box, CCT : 3000K, luminous flux is 2580lm-2850lm, Minimum luminaire Efficacy 95lm/W, Nomnal Luminaire dimensions Top Dia:240mm, Bottom Dia: 306mm, H:104mm
IP66 Outdoor integrated into landscape elements LED linear grazer (OSC-3) with antiglare louver/cowl & surface mounting profile, CCT : 3000K
IP67 Outdoor surface ground LED low height bollard (OSG-3), CCT : 3000K, luminous flux is 1080-1150lm, luminaire efficacy: 77lm/W, Nominal Luminaire dimensions: Top Dia:130mm, Bottom Dia: 165mm, H:157mm
IP67 Outdoor surface ground adjustable LED Floodlight (OSG4) with barn doors, CCT : 3000K, luminous flux is2400-2640lm, luminaire efficacy (min) 120lm/W, IK07 Protection, Nominal Luminaire dimensions L: 155mm, W: 45mm, H: 145mm, F: Dark grey
SPORTS LIGHTING High-quality integrated LED Flood Light with a minimum system lumen of 25000 Lumen and system wattage not exceeding 200W (Nominal) with a nominal efficiency 130 lumen/watt. CCT of 5700K with SDCM of < 5 and CRI: 70. The housing should be of non-corrosive high-pressure die-cast aluminum to with stand extreme environments. It should have corrosion resistant powder coating to pass NSS of 500 Hrs. with PF > 0.95. Lifetime of 50K hours @L70B50. Product should be suitable for continuous operation (10-12 Hrs. per day). The Ingress protection should be minimum IP 66 with an IK rating of 08. Optical and control gear compartments shall be maintainable/replaceable without impacting the LED units. The access to the optical and the gear compartment should be separate. While accessing the gear compartment, the optical compartment should not be accessible. The Luminaire should have a 20 KV /10 KA SPD duly bolted in the Luminaire . The SPD should be able to sustain a minimum 15 hits of 10KA rating i.e. Total of 45 hits across all the three modes as per IEEE 62.41.2. The Luminaire should have a breather to ensure that air balance inside and outside of the Compartment. The luminaire should be of Class B Serviceability.
The wattage of each LED should be greater than 1 watt and less than 3 Watt. Only high power Single white LED chip with ceramic based suitable for outdoor use is allowed. Multi Chip , array multi die , mid power ,Integrated arrays and COB’s are not permitted. The luminaire should be capable of with standing voltage stress of 440V for 8 Hrs., should have an auto shutdown @ 325V and have an auto recovery feature. The Drivers should be a potted driver not a printed circuit board without casing, mounted inside the luminaire. The Dimension of the luminaires should be minimum 538 x 162 x243 mm and have a breather ensuring a stable optical and thermal management. The weight of the luminaire should not be more than 7 Kg. The luminaire should be dimmable with capability of minimum 8 step dimming. There should be provision of remote monitoring and 8 step dimming of the luminaire through existing electrical wiring witout need of any other cabling or any wireless network. (Reference Model BVP483 LED257 CW SMB A1 SIGNIFY)
High-quality integrated LED Flood Light with a minimum system lumen of 25000 Lm and system wattage not exceeding 200W (Nominal) with a nominal efficiency 130 lumen/watt. CCT of 5700K with SDCM of < 5 and CRI: 70. The housing should be of non-corrosive high-pressure die-cast aluminum to with stand extreme environments. It should have corrosion resistant powder coating to pass NSS of 500 Hrs. with PF > 0.95. Lifetime of 50K hours @L70B50. Product should be suitable for continuous operation (10-12 Hrs. per day). The Ingress protection should be minimum IP 66 with an IK rating of 08. Optical and control gear compartments shall be maintainable/replaceable without impacting the LED units. The access to the optical and the gear compartment should be separate. While accessing the gear compartment, the optical compartment should not be accessible. The Luminaire should have a 20 KV /10 KA SPD duly bolted in the Luminaire . The SPD should be able to sustain a minimum 15 hits of 10KA rating i.e. Total of 45 hits across all the three modes as per IEEE 62.41.2. The Luminaire should have a breather to ensure that air balance inside and outside of the Compartment. The luminaire should be of Class B Serviceability.
The wattage of each LED should be greater than 1 watt and less than 3 Watt. Only high power Single white LED chip with ceramic based suitable for outdoor use is allowed. Multi Chip , array multi die , mid power ,Integrated arrays and COB’s are not permitted. The luminaire should be capable of with standing voltage stress of 440V for 8 Hrs., should have an auto shutdown @ 325V and have an auto recovery feature. The Drivers should be a potted driver not a printed circuit board without casing, mounted inside the luminaire. The Dimension of the luminaires should be minimum 538 x 162 x243 mm and have a breather ensuring a stable optical and thermal management. The weight of the luminaire should not be more than 7 Kg. The luminaire should be dimmable with capability of minimum 8 step dimming. There should be provision of remote monitoring and 8 step dimming of the luminaire through existing electrical wiring witout need of any other cabling or any wireless network. (Reference Model BVP483 LED259 CW NB A1 SIGNIFY)
Total of PART III-H - Luminaires
PART III-I - Lightning Protection
LIGHTNING PROTECTION SITC of structurally Integrated lightning protection system confirming to IS/IEC 62305-3,NBC 2016 and IS 3043. includes ring earthing with exothermic weld, raiser conductor and air termination, earthing , test links etc with necessary mounting and fixing accessories . Designing, Supply, installation , Testing & Commissioning of below mentioned Structural Type Lightning Protection System to complete the Job.The quantities given below are approximate for estimation , However exact quantity shall be as per design.
Vertical Air Terminator of SS with Base- 10 mm dia and 1000 mm long. Air Termination Base tested for conditioning, Ageing Test & Lightning impulse current withstand test: 100 kA of 10/350µs waveform in an accredited Third party laboratory as per 6.3 & 6.4 of IEC 62561-1 2017 protocol
10 mm Dia Stainless steel Air termination- 3 Mtrs Long with 2 nos SS Clamp Suitable for side mounting on wall; Supply of Cross splicer Universal cross and T Connector -SS -for 10mm conductor should be tested for conditioning, Ageing Test & Lightning impulse current withstand test: 100 kA of 10/350µs waveform in an accredited Third party laboratory as per 6.3 & 6.4 of IEC 62561-1 2017 protocol
Vertical Air Terminator of SS with Base- 10 mm dia and 1000 mm long. MAST 34mm dia 2 mtr long- Cold Galvanised for RCC roof. Air Termination Base tested for conditioning, Ageing Test & Lightning impulse current withstand test: 100 kA of 10/350µs waveform in an accredited Third party laboratory as per 6.3 & 6.4 of IEC 62561-1 2017 protocol
Concrete block for fixing/Mounting Vertical Air Termination / Mast on RCC Floor with special concrete compound Quick and easy mounting of interception rod using anchor.
10 Dia Stainless steel Air terminator- 2 Mtrs Long with 2 nos SS Clamp Suitable for side mounting on wall;Supply of Cross splicer Universal cross and T Connector -SS -for 10mm conductor should be tested for conditioning, Ageing Test & Lightning impulse current withstand test: 100 kA of 10/350µs waveform in an accredited Third party laboratory as per 6.3 & 6.4 of IEC 62561-1 2017 protocol
Vertical Air Terminator Solid aluminium with Base- 10 mm dia and 1000 mm long mounted on Standing seam fixture for fixing AT on PEB structure. Air Termination Base tested for conditioning, Ageing Test & Lightning impulse current withstand test: 100 kA of 10/350µs waveform in an accredited Third party laboratory as per 6.3 & 6.4 of IEC 62561-1 2017 protocol.
Vertical Air Termination Solid aluminium with Base- 10 mm dia and 1000 mm long ;MAST 34mm dia 1 mtr long- Cold Galvanised for RCC roof;Special Fixing Arrangement for fixing Air Terminal. Air Termination Base tested for conditioning, Ageing Test & Lightning impulse current withstand test: 100 kA of 10/350µs waveform in an accredited Third party laboratory as per 6.3 & 6.4 of IEC 62561-1 2017 protocol;Supply of Vertical Air Terminal of 1 Mtr Mast consisting of Air Terminal with base 34 mm dia and 1000 mm length GI Mast with base plate suitable for mounting on concrete / RCC roof Suitable for high wind load .Mounting arrangement may vary based on site requirement;Special Fixing Arrangement for fixing Air Terminal
8 mm dia solid SS Conductor tested as per IEC 62561- 2 conducted in the Govt. aggregated thirty party laboratory to meet the requirement of IS/ IEC 62305
Polyamide Holder for fixing 8mm dia Conductor
Standing Seam clamp :To hold 8 mm Al conductor at every 1m dist on the top roof without any drilling on roof , Installation can be made through simple fastening system ,mainly used for seaming sheet roof application tested as per IEC-62561-2 for conditioning & Ageing test & conducted in the Govt. accredited Third party laboratory to meet the requirements of IS/IEC 62305
Special fixure Clamp for conductor on Metal Structure roof/wall-Site specific
Concrete block for Conductor fixing- 100x100x50mm thick
Universal cross and T Connector -SS - for 8mm dia conductor
Straight Splicers for 8mm and 10 mm SS Conductor to meet the requirement of IS IEC 62305 tested for conditioning, Ageing Test & Lightning impulse current withstand test: 100 kA of 10/350µs waveform in an accredited Third party laboratory as per 6.3 & 6.4 of IEC 62561-1 2017 protocol
10mm Dia steel conductor with 100 micron copper bonded down conductor solid Conductor (Smooth Surface) to meet the requirement of IS IEC 62305 and tested as per IEC 62561-2
Universal Rebar clamp for holding 10mm Dia Conductor with the Rebar with reinforcement inside the concrete for structural earthing system should be tested for conditioning, Ageing Test & Lightning impulse current withstand test: 100 kA of 10/350µs waveform in an accredited Third party laboratory as per 6.3 & 6.4 of IEC 62561-1 2017 protocol
Universal cross and T Connector -SS -for 10mm conductor
SS Straight Splicers for 8mm and 10 mm Conductor to meet the requirement of IS IEC 62305 tested for conditioning, Ageing Test & Lightning impulse current withstand test: 100 kA of 10/350µs waveform in an accredited Third party laboratory as per 6.3 & 6.4 of IEC 62561-1 2017 protocol
Earthing stud/point of dimension SS-75mm OD plate with 10mm dia tail connector used in structural steel ring earthing system to meet the requirements of IS/IEC 62305. (For Interconnecting the Column and the Terrace AL Conductor / Strip/Flat tested for Electrical resistivity as per IEC-62561-2 conducted in the Govt. accredited thirty party laboratory
SS accessory to connect 8-10 mm conductor to Earth point
25 X 6 mm GI strip from AL Conductor to the earth pit station and further the same strip shall be used for interconnecting all the earth pits below ground leve Zinc coating: 500 g/m square (Approx :70 micron coating) Should be tested and use exclusively for lightning protection ,earthing system and ring equipotential bonding
Holder -GI for fixing 25 x 6 mm GI Strip
Total of PART III-I - Lightning Protection
PART III-J - Earthing
MAINTENANCE FREE EARTHING SYSTEM : MAINTENANCE FREE EARTHING SYSTEM : Supply,installation,testing & commissioning of maintenance free earthing system & associated works, etc. complete as per specifications & instructions of E-I-C. NOTE: Measurement of resistance of earthing grid must be carried out as per instructions of EIC.
Providing & making concrete chamber (1:2:4) of size 600 x 600 x 600 mm (inside dimension) with 10 mm thick MS hinged cover mounted on 40 x 40 x 5 mm thick angle iron frame, 37 x 6 mm & 150 mm long GI equipotential bar mounted inside chamber as per instructions of EIC. (For housing Equipotential bar) Notes: 1. The date of testing and earth resistance value shall be written on the cover with black base with yellow paint. 2. Acceptable earth resistance shall be less than 5 ohm.
G.I. (hot dipped galvanised)/ tinned Cu earth wire/earth strip fixed on wall/side of trench/slab /column /beam/ shaft connection to panel/ DBs/SFU's etc. with 5mm thick G.I. Spacers & 2mm thick G.I. Saddle or in ground at 500 mm below with earth enhancing material surrounding the strip, including excavation in ground, refilling & removal of excess earth within a radius of 500 m, temporary instatement & back filling of trench, consolidation, painting with two coats of black bituminous paint for earth wire/ strip in ground & green enamel paint for earth wire/ strip on surface etc.
50 X 6 mm GI strip
25 X 6 mm GI strip
4mm dia Copper wire
Providing and fixing 6 SWG dia G.l. wire (for loop earthing as required)
Supply & installation of discharge gap device with parallelconnected surge voltage protector to couple differentearthing system similar to M/S OBO make FS-V20 orequivalent in fibreglass reinforced polyester enclosure IP65 & IK08 of size 200 (H) x 250 (W) x 115 (D) mm similarto M/s Spelsberg cat no. Abox-i 250. Note:1) The enclosure housing discharge gap device shall beinstalled in concrete chamber housing equipotential bar 2) The scope includes interconnection of equipotentialbars of lightning & body earthing with suitable size flexibleCu conductor with bimetallic lug at one end as per site &instructions of EIC.
Supply of CPRI tested maintenance free ,Low carbon mild steel copper coated earth rod of 3 metre electrode having diameter of 17.2 mm with copper coating thickness of 250micron tested as per IEC 62561-2 with threaded top with 1 mtr length seperate rod of same dia size with thread at both end with female threaded socket for joining both rods , universal clamp made of SS to connect rod with flat conductor. Earth conductivity enhancing compound shall be of 25 kg/pit tested as per IEC 62561-7,TCLP tested. The above arrangements shall be provided with Heavy duty earth chamber of 5000kg load bearing capacity having rust proof heavy duty weather proof Polyethylene material with following dimensions :254 mm dia (top), 330 mm dia (bottom) & 260mm (height) to ensure the safety of earthing system
Supply of CPRI tested maintenance free, Low carbon mild steel copper coated earth rod of 3 metre electrode having diameter of 14.2 mm with copper coating thickness of 250micron tested as per IEC 62561-2 with threaded top with 1 mtr length seperate rod of same dia size with thread at both end with female threaded socket for joining both rods , universal clamp made of SS to connect rod with flat conductor. Earth conductivity enhancing compound shall be of 25 kg/pit tested as per IEC 62561-7,TCLP tested. The above arrangements shall be provided with Heavy duty earth chamber of 5000kg load bearing capacity having rust proof heavy duty weather proof Polyethylene material with following dimensions :254 mm dia (top), 330 mm dia (bottom) & 260mm (height) to ensure the safety of earthing system.
Total of PART III-J - Earthing
PART III-K - FA
FIRE ALARM SYSTEM Design,supply,installation,testing & commissioning of Analogue addressable microprocessor controlled fire alarm system as per relevant Indian Standard specifications and conforming with relevant specifications of fire authorities of local Municipal Corporation, and as directed by E-I-C. Fire alarm system shall be capable of being IP networked to the central monitoring System connecting through optical Fiber cable network to monitor and integrate above quantity of accessories like detectors, MCP's/ loop power sounder/control modules, Fault Isolation Modules, Loop powered hooters, response indicators, fire/fault indicators, audio-visual signals, central processing units, complete with LED visual indicators, alpha-numeric display and audible alarm both for fire & fault, mains ON indication, test & reset provisions. Each loop should provided with minimum 125 detectors /devices. The panel shall include integral SMF lead acid batteries with sealed cells (max24 V) with appropriate AH capacity, as per IS requirement with integral battery charger, wire way box , if required , front openable lockable cover with front glass etc. complete as required and as per specification & instructions of EIC.
Note: If charger & battery-capacities provided in redymade panel are not meeting operation requirement as per IS 2189 then charger & batteries shall be provided separately including wiring at no extra cost.
Notes: 1) The system shall be got approved by municipal fire authority before start of work and after completion if required. 2) Scope includes submission of factory test report of detectors, break glass and hooters and main panel and final inspection at site. 3) Make of all the components of FAS shall be same. 4) The Panel shall be suitable for networking using open technologies such as TCP/IP, Rs 485, modbus. 5) Capable of being IP networked to the Central Monitoring System connecting through OFC network to monitor & integrate loop devices like detectors, hooters, etc. 6) The panel shall work in degrade mode in case of CPU failure. In the non availability of the feature, a redundant CPU may be provided; having min 640 character alpha numeric display and audible alarm both for fire & fault, mains ON indication , test & reset provisions. 7) Each loop shall provide 150 detectors & devices.
FA Panel: Supply, installation, testing & commissioning of Fire Alarm Panel suitable for wall mounting complete with operating front, loop cards, interconnecting cables etc. as per instructions of FA panel with angle iron framework etc. without extra cost.
2 Loop Panel
6 Loop Panel
Central graphical fire alarm management system to centrally monitor and operate the fire alarm system complete as required.
Repeater panel wih 320 character/ Touch screen LCD display with inbuilt reset, acknowledge and silence switches complete as required.
Intelligent analog addressable photothermal detector complete with mounting base complete as required.
Response Indicator: Response indicator suitable for connecting in parallel to the multisensor & wall mounting type with provision of 25mm dia conduit entries, painting & other materials as complete as per specifications & as per instructions of E-I-C.
Intelligent addressable programmable sounder complete as required.
Fault isolator complete with base as required.
Heat Detectors (Thermal Detectors): Analog Addressable Heat Detectors with solid state design with sensing element combination of fixed type and rate of rise of temperature indicating LED,mounting base etc. as per detailed specification.
Addressable fire control module complete as required.
Addressable Monitor module complete as required.
Addressable beam detector with short circuit isolator (inbuilt or seperate) complete with emitter and receiver including connections with remote test features etc complete as required.
Intelligent addressable duct detector including suitable Photo detector complete with base as required.
Manual Call Point :Dust and vermin proof Addressable Manual Call Point
Addressable horn cum strobe complete as required.
Addressable strobe complete as required.
Fire fighter telephone handset complete as required.
Fire fighter phone jack complete as required.
Wiring for Fire Alarm System :Wiring with 2x1.5 sqmm fire survival armoured cable, 600/1000V rated with annealed copper conductor having glass mica fire barrier tape covered by an extruded layer of Cross Linkable Ethylene Propylene Rubber (EPR) insulation and LSZH inner bedding, steel wire armouring & LSZH outer sheath complete as required. termination’s as required, complete as per instructions of E-I-C.
Total of PART III-K - FA
PART III-L - LAN System
LAN SYSTEM Special Conditions: 1. CAT-6A cabling for DATA, voice & wifi. 2. CAT-6 cabling for CCTV and access control system. 3. Separate colour code for copper cabling of Data, Voice & Other services like CCTV, Access control system. 4. Separate colour for I/Os of different systems. 5. Separate colour for Patch cords accordingly. 5. Testing & Performance requirement with 25 years certificate.
LAN rack :Supply, installation, testing & commissioning of double section 19" wall/floor mounted pivoting type, following size/height rack having safety glassdoor, 2 PDUs per rack & with standard accessories, including power supply panel, fans, cable manager, full cable entryplate with brush at top & bottom etc. complete as required & as per instructions of EIC.
42U Rack 800x1000
15U Rack 600x600
9U Rack 600x600
Horizontal Cabling for DATA, Voice & Wi-Fi
Supply, Installation, Testing and Commissioning of Cat6A U/UTP 23 AWG LSZH cable complete in all respect complying EIA/TIA atandards.
Supply, Installation, Testing and Commissioning of Cat6A U/UTP Tool Less Termination, 23 AWG, Information Outlet with multiple color options
Supply, Installation, Testing and Commissioning of Simplex/Duplex Faceplate as per requirement including compatible concealed metal/GI box.
Supply, Installation, Testing and Commissioning of 19" 1U Straight Modular Type 24 port fully loaded CAT-6A Patch Panel Black Powder coated with all accessories with cable manager, labelling for idntification complete as per EIA/TIA standards.
Supply, Installation, Testing and Commissioning of Cat6A U/UTP LSZH 3m. Patch cord of following sizes with multiple color options as per EIA/TIA standards.
Horizontal Cabling for CCTV & ACS
Supply, Installation, Testing and Commissioning of Cat6 U/UTP 23 AWG LSZH cable complete in all respect complying EIA/TIA atandards & IEC 60332-1.
Supply, Installation, Testing and Commissioning of Cat6 U/UTP Tool Less Termination, 23 AWG, Information Outlet with multiple color options
Supply, Installation, Testing and Commissioning of Simplex /Duplex Faceplate including compatible concealed metal/GI box.
Supply, Installation, Testing and Commissioning of 19" 1U Straight Patch Panel Modular Type including compatible concealed metal/GI box. Loaded Black Powder coated with all accessories
Supply, Installation, Testing and Commissioning of Cat6 U/UTP LSZH 3m. Patch cord with multiple color options
Back Bone Cabling from Core to Distribution
Supply, Installation, Testing and Commissioning of 12 Core Single mode OS2 Outdoor Armored HDPE/LSZH Cable in 40/33 mm OD/ID self lubricated HDPE pipe in ground at depth of 750 mm sand bedding, laying of warning tape on top, temporary reinstatement, back filling of trench, disposal of excess earth at radius of 500mm or in existing conduit/cable tray consolidation, paintig with two coats of black bituminous paint of earth wire/strip in ground & green enamel paint for earth wire/strip on surface. Notes: 1. Excavation in soft soil /soft rock to be measured under item xxxxx of secxxxx. 2. Scope includes HDPE pipe with accessories such as warning tape, coupler,cable end plug, cable sealing plug, etc.
Supply, Installation, Testing and Commissioning of 19" 1U Fiber Panel fully Loaded with 24 port LC Duplex SM Adapater, OS2 Pigtails, spool and splice trays with all accessories.
Supply, Installation,Termination, Testing and Commissioning of 19" 1U Fiber Panel (LIU)fully Loaded with 12 port LC Duplex SM Adapater, OS2 Pigtails, spool and splice trays with all accessories.
Supply, Installation, Testing and Commissioning of LC LC Duplex SM OS2 Fiber Patch cord LSZH 3m
Total of PART III-L - LAN System
PART III-M - UPS
Supplying and erecting approved make online 60 KVA Un-interruptible Power Supply system comprising float cum-boost charger with IGBT base rectifier & Inverter & sealed maintenance free SMF batteries. Inverter having output 440V,50 Hz Ac with 0.8 load power factor with three phase input & three phase output with over/under voltage output with over load & short circuit protection equipment. The system housed in CRC sheet duly powder coated paint with 10 Mins backup.with MS painted batteries stand, 10% Overload capacity for momentary load.
Supplying and erecting approved make online 30 KVA Un-interruptible Power Supply system comprising float cum-boost charger with IGBT base rectifier & Inverter & sealed maintenance free SMF batteries. Inverter having output 440V,50 Hz Ac with 0.8 load power factor with three phase input & three phase output with over/under voltage output with over load & short circuit protection equipment. The system housed in CRC sheet duly powder coated paint with 10 Mins backup.with MS painted batteries stand, 10% Overload capacity for momentary load.
Supplying and erecting approved make online 20 KVA Un-interruptible Power Supply system comprising float cum-boost charger with IGBT base rectifier & Inverter & sealed maintenance free SMF batteries. Inverter having output 440V,50 Hz Ac with 0.8 load power factor with three phase input & three phase output with over/under voltage output with over load & short circuit protection equipment. The system housed in CRC sheet duly powder coated paint with 10 Mins backup.with MS painted batteries stand, 10% Overload capacity for momentary load.
Supplying and erecting approved make online 10 KVA Un-interruptible Power Supply system comprising float cum-boost charger with IGBT base rectifier & Inverter & sealed maintenance free SMF batteries. Inverter having output 440V,50 Hz Ac with 0.8 load power factor with three phase input & three phase output with over/under voltage output with over load & short circuit protection equipment. The system housed in CRC sheet duly powder coated paint with 10 Mins backup.with MS painted batteries stand, 10% Overload capacity for momentary load.
Supplying and erecting approved make online 6 KVA Un-interruptible Power Supply system comprising float cum-boost charger with IGBT base rectifier & Inverter & sealed maintenance free SMF batteries. Inverter having output 440V,50 Hz Ac with 0.8 load power factor with three phase input & three phase output with over/under voltage output with over load & short circuit protection equipment. The system housed in CRC sheet duly powder coated paint with 10 Mins backup.with MS painted batteries stand, 10% Overload capacity for momentary load.
Total of PART III-M - UPS
PART III-N - HT Panel
HT PANEL COMMON NOTES FOR HT PANELS: 1) Interlock shall be provided between incomer & bus coupler breakers such that it shall be possible to close only any two breakers at a time. 2) Intertripping between upstream & downstream breakers of transformer feeder shall be provided. 3) Routine tests on breaker shall be performed in presence of departmental engineers as per relevant specifications at works. Type test certificate as indicated in the specification shall be submitted prior to inspection & testing at manufacturers works. 4) Proper labels and ferrule numbers should be affixed alongside various components and control wire. Concurence of dept. engineers shall be obtained on location, qty. etc. 5) Tenderer shall hire manufacturer commissioning team or their authorised representatives for installation, testing & commissioning of HT switchboard at site. 6) Provision of cable entry shall be from bottom only. 7) The HT Panel shall be extensible type on both sides to accommodate future 36kV Panels. 8) All the VCB shall be interchangeable.
9) HT Panel shall have provision for remote monitoring / control through central station unit through SCADA, in future. Therefore, following provisions shall be made for BMS compatibility : 1) Breaker 'ON', 'OFF', 'Trip', Test / Service / isolation position, ready to close, Spring Charged to be provided in form of soft data points i.e. on RS-485 port with Modbus protocol/ with potential free contacts. 2) Suitable I/O points shall be provided for remote control of incomer & bus coupler breaker through SCADA screen. 3) All numerical relays and multifunction meters shall be provided with RS-485 port on Modbus communication protocol. 4) All communication devices should be compatible and set on same baud rate. 5) MS channels (ISMC 100) required for installation of Panel on cable trench including cutting of chequered plate cover etc. is included in the scope of work.
36 KV Indoor Vacuum Circuit Breaker Switchboard: Design, manufacture, shop testing at works, supply, assembling, installation, precommissioning testing at site and commissioning of 36 KV,1250 A, 25 KA, breaking capacity at 33 KV, 3 pole metal clad indoor vacuum circuit breaker switchboard, IP 4X including all relays, meters, CTs & other accessories with 3 phase insulated/ encapsulated copper bus bars of 1250 A rating (high conductivity, electrolytic copper ). The closing and tripping coil should be rated for 110V AC/DC supply & 230 V AC for spring charging motor. The cubicle shall be type tested for internal arc in all three breaker, bus bar & cable compartment for 25kA for 0.1 sec. The 36 kV Switchboard shall be comprising of :
Breaker Switchboard: Design, manufacture,shop testing at works, supply, assembling, installation,precommissioning testing at site and commisioning of 36 KV,1250 A, 25 KA ,breaking capacity at 33 KV, 3 pole metal clad indoor vaccum circuit breaker switchboard, IP 4X including all relays, meters, CTs & other accessories with 3 phase insulated/ encapsulated copper bus bars of 1250 A rating (high conductivity, electrolytic copper ) . The closing and tripping coil should be rated for 110V AC/DC supply & 230 V AC for spring charging motor. The cubicle shall be type tested for internal arc in all three breaker, bus bar & cable compartment for 25kA for 0.1 sec. The 36 kV Switchboard shall be comprising of
Design, manufacture,shop testing at works, supply, assembling, installation,precommissioning testing at site and commisioning of 36 KV,1250 A, 25 KA ,breaking capacity at 33 KV, 3 pole metal clad indoor vaccum circuit breaker switchboard, IP 4X including all relays, meters, CTs & other accessories with 3 phase insulated/ encapsulated copper bus bars of 1250 A rating (high conductivity, electrolytic copper ). The closing and tripping coil should be rated for 110V AC/DC supply & 230 V AC for spring charging motor. The cubicle shall be type tested for internal arc in all three breaker, bus bar & cable compartment for 25kA for 0.1 sec.
Flooded Lead Acid Tubular Battery with Battery Charger: Supply, installation, testing & commissioning of Lead acid battery set with polypropylene container comprising of 55 cells of 2V, 100AH capacity at 10hr rate of discharge complete with inter cell connectors, acid level indicating floats etc. all as per IS 1651 1984 and as per instructions of E-I-C & as per technical specifications.The following accessories shall be included in the scope of work: a) Battery stand constructed out of Teak wood and coated with anti acid paint suitable suitable for accomodating above cells in single row double tier arrangement b) Tubular type cells c) Stand insulators d) Syringe type hydrometer suitable for specific gravity readings - 2 nos. e) Thermometers -2nos. f) Digital type cell testing voltmeter (3-0-3) complete with leads - 2 nos. g) Spanner (Inter connector bolt wrenches ) - 2 nos. h) Inter cell connector with nuts, bolts & washers i) Vent plugs
j) Acid resisting jugs & funnels - 1 set k) Rubber gloves & Rubber Aprons - 2 nos. l) Protective Goggles - 2 nos. m) Syringes n) Small pack of petroleum jelly o) Teak wood hoolder for thermometer & hydrometer - 2nos. Scope includes suitable battery charger cubicle panel, indoor type, IP 42, floor mounted intended to operate on 415 V 50 Hz 3 phase, 4-wire incoming supply. The charger unit shall be complete with float charger & boost charger along with relays, contactor, switches, Ammeter,voltmeter etc complete as required & as per manufacturers standard design. The scope also includes supply of DCDB which shall be common for both battery banks with 1 no. incomer and 8 nos. outgoings MCB.
Total of PART III-N - HT Panel
PART III-O - HT Cable & End Termination
HT Cable & End Joint :
Supply, Installation, Testing & Commissioning of following voltage grade Aluminium stranded circular core conductor with semi conductor shielding, XLPE insulation with semi conductor sheilding & copper tape screening, PVC (ST-2) extruded inner sheath, G.I strip/ wire armoured, anti rodent & anti termite, FRLS PVC (ST-2) outer sheathed cable conforming to IS 7098 (Part-II) with latest amendments, laid in ground /in existing hume pipes/ on wall / in cable trench/on existing cable tray etc. as required ,as per technical specifications and as per instructions of EIC. NOTE: 1. Clamping of cables on trays including supply of clamping materials as per instruction of EIC shall be included in the scope of work. 2. Cost of excavation shall be paid under relavent item
33kV(E), 3Cx300 sqmm FRLS XLPE Aluminium cable
HT Cable End Joint : Supply,installation and termination for following voltage grade Aluminium conductor armoured XLPE insulated cable including heat shrinkable indoor jointing kit complete with tinned copper lugs,all accessories and materials required to make complete joint as required and as per technical specification & as per instruction of EIC. Note: HI-pot testing & commissioning of joint is included in the scope of this item.
33KV (E), 3Cx300 Sq.mm XLPE Al conductor cable
HT Straight Through Cable Joints : Supply,installation, testing & commissioning of straight through joint for following voltage grade Aluminium conductor armoured XLPE insulated cable including heat shrinkable jointing kit complete with tinned copper ferrules,all accessories and materials required to make complete joint as required and as per technical specification & as per instruction of EIC. Note: HI-pot testing & commissioning of joint is included in the scope of this item.
33KV (E), 3Cx 300 Sq.mm XLPE Al conductor cable
Total of PART III-O - HT Cable & End Termination
PART III-P - ONAN Transformers
TRANSFORMERS Design, manufacture, shop testing at works, supply, assembling, installation, precommissioning testing at site and commissioning of following capacities & voltage rating, ONAN, 50 Hz, Dyn 11, core type, double wound outdoor type transformer with transformer oil, copper winding, degree of protection IP-55 complete with H.V cable box with disconnecting chamber having inspection cover suitable to receive HT XLPE insulated armoured cable and LT box suitable for LT Al sandwich type bus duct, neutral CT 4000/1A, Class PS with Vk, Imag, Rct suitable value for REF protection, Winding temperature indicator, Oil temperature indicator, MOG , Bucholz relay, Oil surge relay (OSR), ON Load tap changer with RTCC Panel with AVR (+10% to -10% in steps of 1.25%), standard mounting accessories, fittings, etc., first filling of oil, painting at works & touch up painting at site etc including 10% extra transformer oil in non returnable drums. Transformer shall be suitably mounted on rail including supplying & grouting of rail and locking the bidirectional flanged wheels of transformer.
Note :- 1) G.A drawings to be got approved from E.I.C 2) Tenderer shall hire transformer OEM commissioning team or their authorised representatives for installation, testing & commissioning of Transformers. 3) Use of crane and other tools & plants for assembly of transformer is included in the scope of item. 4) Routine tests & acceptance test on transformer shall be performed in presence of departmental engineers as per relevant specifications at works before despatch . Type test certficate as indicated in the specification shall be submitted along with GTP during tender evaluation stage. 5) The transformer shall conform to Energy efficiency level 2 as per IS 1180 (Part-1) : 2014. 6) Transformer shall meet all the technical requirement of specifications. 7) Filteration of transformer oil & OLTC at site, topping of oil after filteration including complete oil testing from NABL accredited lab , all as per relevant IS specifications & as per instructions of E.I.C are included in the scope of tender. 8) WTI/OTI setting for alarm & Trip shall be marked on marshalling Box by permanent Marker 9) Neutral of Transformer shall be identified by name or Green Color.
10) Size of cable & source from which supply is given to the equipment shall be written on terminal box of the Transformer. 11) The control cabling between marshalling box & RTCC with armoured Cu cable of min. 1.5sqmm size shall be included in the scope of work.
2.5 MVA, 33/0.433 kV transformer as per above description
Temperature rise test & Impulse test on Transformer as item no. 13.1 as per IS 2026 on 1 no. transformer
800 KVA, 33/0.433 kV transformer as per above description Temperature rise test & Impulse test as per IS 2026 on 1 no. transformer
Temperature rise test & Impulse test on Transformer as item no. 13.3 as per IS 2026 on 1 no. transformer
Total of PART III-P - ONAN Transformers
PART III-Q - Dry Type Transformers
Suply, installation, testing and commissioning of Indoor air cooled Cast resin Dry type transformer 100 KVA 33/0.415 kV, 3 phase, 50 Hz, Dyn 11 vector group, copper wound, class-F insulation, enclosed in MS CRCA powder coated enclosure of minimum 2 mm thickness with IP-23 degree of protection . Transformer winding shall be protected by means of winding temperature indicator/controller actuated by means of resistance temperature detector embedded in LV windings. Spare RTD embeded in windings shall be wired and brought upto marshalling box. The transformer shall have cable end boxes on both sides suitable for 1 no. 3.5C x 95 sqmm Al XLPE cable. The transformer enclosure shall be suitably mounted on M.S. channel including supplying and grouting of suitable M.S. channel with all accessories and confirming to IS 2026 & as per specification attached & instructions of EIC. The transformer losses shall be as per ECBC-2017 latest revision
Total of PART III-Q - Dry Type Transformers
PART III-R - BUS DUCT
BUS DUCT Supply, Installation, Testing & Commissioning of readymade 415 V, 50Hz, triple pole & neutral totally enclosed, IP 54 for indoor mounting, 1.5 mm GI sheet steel clad, duly powder coated bus duct with compact sandwiched type insulated Aluminium bus bars having following configuration: a) Bus bar current rating : 4000A/ 1250A b) Bus bar configuration : 3 Phase + neutral Al bus bar. Neutral shall have 100% capacity. c) Symetrical short circuit rating :65 kA at 415 V d) External earthing : 2 nos 50 x 6 mm GI strip to be measured under item 'Maintenance Free Earting' of Electrical Section respectively. The bus duct shall be complete with following components / accessories inclusive of joint covers as required,wall crossing unit with fire barrier, transposition units etc. as required & as per instructions of EIC & as per technical Specification. Any components/features etc not specifically mentioned but which are required functionally & for safety of system shall be inlcuded in scope of work without extra financial implication. The cost of supporting arrangement by MS angle, hangers, vertical supports etc. shall be included in the scope of work. Any components/features etc not specifically mentioned but which are required functionally & for safety of system shall be inlcuded in scope of work without extra financial implication.
Notes: 1) The horizontal/ Vertical elbow shall be measured seperately under item 'vertical elbow' & 'Horizontal elbow' as mentioned in below sub-section 15.1.3, 15.2.3 & 15.3.3 below. The elbow shall not be measured in straight length feeder. 2) All routine, acceptance & temperature rise test of each rating of bus duct shall be carried out in manufacturer's factory in presence of departmental representatives.
For 4000A Bus Duct :
Copper braided flexible jumper for ATS/ LT Panel end connection, Panel to Panel interconnection. (1 set = RYBN) (1 set = RYBN)
Flange end unit Note: The scope shall include providing flange end box, if necessary, to match Panel & transformer end dimensions with flange dimensions etc. Rubber bellows shall be provided between flange end/box & transformer terminal box for vibration isolation. Note: The scope shall include providing flange end box, if necessary.
90 degree Vertical/ Horizontal elbow
Straight length feeder
For 2500A Bus Duct :
Copper braided flexible jumper for ATS/ LT Panel end connection, Panel to Panel interconnection. (1 set = RYBN) (1 set = RYBN)
Flange end unit Note: The scope shall include providing flange end box, if necessary, to match Panel & ATS end dimensions with flange dimensions etc. Note: The scope shall include providing flange end box, if necessary. Rubber bellows shall be provided between flange end/box & alternator terminal box for vibration isolation.
90 degree Vertical/ Horizontal elbow
Straight length feeder
For 1250A Bus Duct :
Copper braided flexible jumper for ATS/ LT Panel end connection, Panel to Panel interconnection. (1 set = RYBN) (1 set = RYBN)
Flange end unit Note: The scope shall include providing flange end box, if necessary, to match Panel & ATS end dimensions with flange dimensions etc. Note: The scope shall include providing flange end box, if necessary. Rubber bellows shall be provided between flange end/box & alternator terminal box for vibration isolation.
90 degree Vertical/ Horizontal elbow
Straight length feeder
Total of PART III-R - BUS DUCT
PART III-S - DG SET
Supply, erection, testing and commissioning of 3 phase 415 volts 50 cycle per second 1500 RPM radiator cooled by water with fan etc. Diesel Generator Sets of rating as below. The engine shall be 4 stroke and shall include flywheel to suit rigid coupling with guard, stainless steel bellow, air cleaner, fuel pump, electronic variable speed governor complete with all accessories fuel filter, lub oil filter & pump, dynamo, Lead acid type battery of capacity as suggested by manufacturer, battery stand, battery cable,engine controller along with fuel tank hand pump and complete as required comprising of switch with key, 990 ltrs day oil tank (as per Item No. 16.11 of this Section), fuel piping from day tank to DG Set, residential silencer etc. as required. The alternator shall be seperately excited through PM exciter, self regulated and continuously rated as below suitable for 3 phase 415 volts 50 cycles, 0.8 pf,4 wire system and shall be provided with brushless excitation unit, Alternator insulation shall be class 'H' suitable to withstand tropical conditions and shall generally comply with BS 5000 and IS 4722 and suitable for working on
Synchronisation Panels complete with Droop CT's etc. as required. The overload capacity shall not be less than 110% of rated capacity for 1 hour in every 12 hours. The terminal box shall be suitable for termination of sandwich type bus duct along with bellow. The DG set shall be mounted on a fabricated rigid common base frame with resilient anti-vibration mountings to provide 70% vibration isolation or better. The DG set shall include all accessories, fittings and instrument complete as per specifications and as required. The entire D.G. Set shall be housed in Sound & Weatherproof accoustic enclosure, suitable for indoor duty, as per Central Pollution Control Board latest norms and as per details given in Technical Specifications. An additional hot air duct shall be provided on the top of enclosure at radiator end for directional dissipation of radiator exhaust outside DG room.
The scope includes obtaining approval of erection of D.G. Sets from latest CPCB/ PWD / State Government & other statutory bodies as applicable.Rates for above activities, shall be inclusive of : a) Preparation of layout drawings, follow up of necessary applications , liason with all Govt. bodies for approvals etc. The Payment towards fees/registration charges shall be made by TIFR and receipt shall got prepared in the favour of authorities making payments. b) Testing of assembled DG set at works & at site. Necessary load bank for site testing shall be included in scope. c) Control cabling between DG sets , Synchronizing and Main emergency Panel Panel with shielded / unshielded cable as per OEM recommendations.
750 kVA DG set
Exhaust Piping: Design, Supply, installation, testing and commissioning of following MS exhaust piping, heavy duty class-B complete with all accessories such as bends flanges, flexible connections at a suitable distance etc. and insulated with 75 mm thick layer of LRB rock wool having 96 kg/m3 density, cladding with 24 gauge aluminium sheet all-round the exhaust pipe complete as required at site indoor and outdoor, exhaust piping shall be extended above S/S building height as per as per MoEF/CPCB norm including MS supports properly painted,fixing of residential grade silencers, flexible bellows complete as per technical specifications & instructions of EIC. Note: 1) The outdoor exhaust piping shall be supported by free standing MS structure grouted in concrete foundation & shall got approved by EIC before execution. 2) Free standing MS structure consisting of MS angle iron / channel/sheet complete with two coats of enamel paint shall be measured seperately under item no. 4.0 of Section-VII. 3) The RCC foundation for free standing MS exhaust structure shall be measured seperately under respective items of Section-VIII.
300 mm dia ( I/D)
250 mm dia ( I/D)
HSD storage tank : Design, Supply and fabrication of Underground Bulk Oil (HSD) Storage Tank, with dished ends, of 20,000 ltrs nominal capacity conforming to IS 10987 - 1992. The tank shall be fabricated from MS plates as per IS 2062, 6 mm thick for tanks and 8 mm thick for ends, provided with all standard appurtenances/ mountings like manholes with hinged cover, access ladders, lifting lugs, earthing bosses, appurtenances for fill, suction and sump overflow connections, dip stick, vent pipe, 2 coats of Black bituminous paint on outside surface of the tank etc. complete as per specifications and as required. The scope also includes installation, testing and commissioning of the Bulk Oil Storage Tanks as above below ground level including the cost of providing asphalt doping after surface preparation , sand filling, compaction, levelling, dressing etc. complete as required.
Notes: 1) The successful Tenderer shall submit all the drawings for approval as per the norms required by the statutory authorities such as PESO, Fire service Department & local PCB etc. The necessary approval and obtaining safety certificate/NOC/license for HSD tank with connected works as required at site is included in the scope of work. 2) Contractor to design and install tank with all require components and accessories if anything missing to mentioned.
Fuel Transfer Pumps: Design, Supply, installation, testing and commissioning of 110 lpm at 20m head Fuel Transfer Pump sets with rotary gear pumps and flameproof motors suitable for transferring HSD oil from the Underground Bulk Storage Tank to the Oil Tanks in DG room. (One No. Pump shall be standby). Note: a) All pumps shall be flame proof /explosion proof. Squirrel cage induction motor suitable for Zone 1 & Gas group IIA & IIB and as per IS:2148 or equivalent std. b) Motors shall be induction type, squirrel cage with sealed bearing & suitable for 415V AC, 50Hz, 3 phase power supply. c) Contractor to design and install system with all require components and accessories.
Fuel piping : Design, Supply, laying testing and commissioning of Oil piping with heavy duty MS pipes as per IS 1239, laid directly buried in ground including the cost of bends, supports, clamps etc. and including the cost of earth works (excavation and back filling) and including the cost of surface preparation of pipes, application of corrosion protection tape similar to Pypekote' and including the cost of hydraulic testing before wrapping of rust preventing tape complete as per specification, as required and as below. Contractor to design completed sysem and install with all require components and accessories if any missing below.
80 NB (Fill pipe)
50 NB (Suction piping)
25 NB (from buffer tank to day tank, Overflow piping to return line)
Supply, installation, testing and commissioning of piping accessories complete as required and as below:
80 NB flexible hose with flanged ends suitable for oil company's delivery hose.
80 NB brass gate valve
80 NB strainer with SS screen of 80/100 mesh.
Oil recording flow meter
50 NB brass foot valve
50 NB ball valves.
50 NB brass Y strainer
50 NB brass check (NRV) valve
25 NB ball valves
Pressure Gauge 6" Dial sealed Diaphragm Type, 0-25k/sq.cm range with shut-off cock.
Pump Starter Panel : (Non-design verified assembly as per IEC-61439): Design, Supply,installation,Testing and Commissioning of outdoor Flame proof DOL starter Panel with following configuration and floor/wall mounting complete with all mounting accessories etc. as per instructions of EIC. Panel shall be communicable type and integrate with BMS. Incomer: 1) 1 no. 125A FP MCCB with microprocessor based O/C+ S/C release. 2) 1 set of RYB indication lamps with control fuses. 3) 3 nos. 125/5 5VA class 1.0 CT 4) 1 no. Digital Multi function meter, Acc. Cl-1.0 Busbar: Tinned Cu TPN busbars rated at 100 A having a maximum current density of 1.24 A /sqmm suitable to with stand symmetrical fault level ocurrent density of 1.24 A /sqmm suitable to with standf 25 kA at 415 V. The neutral is to be of 100 % capacity of phase busbar. Outgoing feeders : A) Starter for Fuel transfer pump:- 2 sets DOL starter suitable for fuel transfer pump 110 lpm at 20m head with fuseless backup protection
Supply, Erection, Testing and commissioning of Weather & Flame Proof Local ON/OFF Push Button Station suitable for outdoor mounting with suitable MS angle iron frame work etc, including internal wiring etc. complete as required and instructions of EIC.
Supply, erection, testing and commissioning of 3 phase 415 volts 50 cycle per second 1500 RPM radiator cooled by water with fan etc. Diesel Generator Sets of rating as below. The engine shall be 4 stroke and shall include flywheel to suit rigid coupling with guard, stainless steel bellow, air cleaner, fuel pump, electronic variable speed governor complete with all accessories fuel filter, lub oil filter & pump, dynamo, Lead acid type battery of capacity as suggested by manufacturer, battery stand, battery cable,engine controller along with fuel tank hand pump and complete as required comprising of switch with key, 990 ltrs day oil tank (as per Item No. 2.0 of this Section), fuel piping from day tank to DG Set, residential silencer etc. as required. The alternator shall be self excited, self regulated and continuously rated as below suitable for 3 phase 415 volts 50 cycles, 0.8 pf,4 wire system suitable for operation at 50 degree C ambient , accordingly derating shall be considered and shall be provided with brushless excitation unit, Alternator insulation shall be class 'H' suitable to withstand tropical conditions and shall generally comply with BS 5000 and IS 4722.
The overload capacity shall not be less than 110% of rated capacity for 1 hour in every 12 hours. The terminal box shall be suitable for termination of sandwich type bus duct along with bellow. The DG set shall be mounted on a fabricated rigid common base frame with resilient anti-vibration mountings to provide 70% vibration isolation or better. The DG set shall include all accessories, fittings and instrument complete as per specifications and as required. The entire D.G. Set shall be housed in Sound & Weatherproof accoustic enclosure, suitable for indoor duty, as per Central Pollution Control Board latest norms and as per details given in Technical Specifications. An additional hot air duct shall be provided on the top of enclosure at radiator end for directional dissipation of radiator exhaust outside DG room. The scope includes obtaining approval of erection of D.G. Sets from latest CPCB/ PWD / State Government & other statutory bodies as applicable. Rates for above activities, shall be inclusive of :
a) Preparation of layout drawings, follow up of necessary applications , liason with all Govt. bodies for approvals etc. The Payment towards fees/registration charges shall be made by GCNEP/DAE and receipt shall got prepared in the favour of authorities making payments. b) Testing of assembled DG set at works & at site. Necessary load bank for site testing shall be included in scope. c) Control cabling between DG sets , Synchronizing and Main emergency Panel Panel with shielded / unshielded cable as per OEM recommendations.
320 kVA DG set
Supply, installation, testing and commissioning of 990 liters capacity buffer & Day Fuel Tanks, fabricated from 3 mm thick M.S. sheets including the cost of removable cover with locking arrangement, painting and also providing all the required appurtenances like inlet and outlet connections, float valves, drain connection, overflow connection to oil sump, Prismatic oil level indicator and including the cost of support arrangement etc. complete as required.
Supply & installation of Electronic level controller cum sensor with high and low level limits in buffer tank suitable- for automatic operation of solenoid valve & main fuel transfer pump.
Total of PART III-S - DG SET
PART III-T - Roof Top Solar
ROOF TOP SOLAR Design, supply, installation, testing and commisisoning of 250 KWp Roof top solar system on buildings(Proposed Location: Research block-1&3) having 550Wp Mono crystalline solar PV cells along with require size or capacity of Inverter as per design and site condition. Scope shall also include hot dip galvenized structure, AC and DC DBS along with all relative cables, earthings, LA and all other require components and accessoires to finish the job . Contractor shall also supply generation meter and Net meter as per local Electricty board specification and requirement. All satutory approval from authority /concern departments shall also be part of contractor's scope of work. Note: Designing of Solar PV system on PV SYST or equivalent software along with STADD analysis of solar PV structure, Array layout drawings, SLD's of system etc. The same shall be submitted to the department approvals.
Following scope shall be part of contract: 1. Contractor to do detail feasibility on site. 2. Contractor to provide detail technical design report. 3. Prepare Overall layouts and General arrangement of the components. Single line diagram, Civil requirement drawing etc. 4. Provide all technical data sheets of all components. 5. Quality Assurance plan. 6. As built drawings. 7. Project Hand over documents.
Total of PART III-T - Roof Top Solar
PART III-U - Lifts
The lift shall be machine room less type with gearless machine in the shaft on top of guiderails.Complete with all accessories including automatic rescue device and having following other features. Including all steel civil and electrical work required for installation of elevator in the existing lift well and machine room, scaffolding, cutting holes, grouting and making good to damages in wall , floor, ceiling etc. for fixing accessories foundation bolts etc., hoistway wiring and other associated wirings including fireman's switch complete in all respect and also conveyance, loading, unloading, royalties, taxes all material and cost all labours sundries, TandP required as per the direction of the Engineer-in-charge.
Landing operating panel - Red LED Dot Matrix Individual landing operating panel for each elevator with buttons Car Operating Panel - Red LED Dot Matrix fill length panel with buttons and braille
Handrail - Round handrail in Stainless Steel finish provided on rear wall of car Landing operating panel - Red LED Dot Matrix Individual landing operating panel for each elevator with buttons Car Operating Panel - Red LED Dot Matrix fill length panel with buttons and braille
Handrail - Round handrail in Stainless Steel finish provided on rear wall of car Landing operating panel - Red LED Dot Matrix Individual landing operating panel for each elevator with buttons Car Operating Panel - Red LED Dot Matrix fill length panel with buttons and braille
Handrail - Round handrail in Stainless Steel finish provided on rear wall of car Landing operating panel - Red LED Dot Matrix Individual landing operating panel for each elevator with buttons Car Operating Panel - Red LED Dot Matrix fill length panel with buttons and braille
Handrail - Round handrail in Stainless Steel finish provided on rear wall of car Landing operating panel - Red LED Dot Matrix Individual landing operating panel for each elevator with buttons Car Operating Panel - Red LED Dot Matrix fill length panel with buttons and braille
Handrail - Round handrail in Stainless Steel finish provided on rear wall of car Landing operating panel - Red LED Dot Matrix Individual landing operating panel for each elevator with buttons Car Operating Panel - Red LED Dot Matrix fill length panel with buttons and braille
The lift shall be machine room less type with gearless machine in the shaft on top of guiderails.Complete with all accessories including automatic rescue device and having following other features. Including all steel civil and electrical work required for installation of elevator in the existing lift well and machine room, scaffolding, cutting holes, grouting and making good to damages in wall , floor, ceiling etc. for fixing accessories foundation bolts etc., hoistway wiring and other associated wirings including fireman's switch complete in all respect and also conveyance, loading, unloading, royalties, taxes all material and cost all labours sundries, TandP required as per the direction of the Engineer-in-charge.
SL-1 (Research Lab) Capacity - 2500 KG Speed - 0.50 m/s No. of Stops - 4 Travel Height - 5.4/7.2 m Control - Simplex Full Collective Control Well Dimension - 3000 mm width and 3000 mm depth (required) Head Room height - 4500 mm (required) Pit Height - 1900 mm (required) MAP Floor Position - Topmost floor (TOP) Car dimensions - 2000 mm wide x 2300 mm deep x 2300 mm high Door dimensions - 1400 mm wide x 2100 mm internal height Car door - 4 panel automatic center opening door with ACVF drive Finishes & Accessories: Car doors - SUS 304/ AISI441 (or equivalent) with hairline finish Car suspended ceiling- Stainless Steel Silver Sky finish with round/square LED for car lighting Car flooring - 6mm ST - Checkered, steel; with car skirting of SS hairline finish
Handrail - Round handrail in Stainless Steel finish provided on rear wall of car Landing operating panel - Red LED Dot Matrix Individual landing operating panel for each elevator with buttons Car Operating Panel - Red LED Dot Matrix fill lenggth panel with buttons and braille
Total of PART III-U - Lifts
PART III-V - Miscellaneous
CABLE TRAYS AND CABLE MANAGEMENT SYSTEM : Providing and fixing approved make Ladder type cable tray. Made from M.S sheet. The cable tray should be bended as per IS 2062/1079 shall be fabricated of double bended channel section longitudinal members with single bended Channel section. Rungs of members welded to the base of the longitudinal members at 250 mm c/c spacing . as per IS and shall be coated with hot dip galvanizing of 80 micron as per IS 2629/4759. with coupler plate / Fish plate and GI hardware like nut - bolt and washers & other accessories etc. erected on existing support as per Specification and as per instruction of engineer in charge.Rate Should include all bends , cross members , T Joints etc as per the requirement of site.
150 X 50 X 1.6 mm Thick
200 X 50 X 1.6 mm Thick
300 X 100 X 2.0 mm Thick
450 X 100 X 2.0 mm Thick
600 X 100 X 2.0 mm Thick
900 X 100 X 2.0 mm Thick
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray with single bended channel section along with cable tray cover (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.l. suspenders including G.l. bolts & nuts, etc. as required.
100 mm width X 50 mm depth X 1.6 mm thickness
150 mm width X 50 mm depth X 1.6 mm thickness
200 mm width X 50 mm depth X 1.6 mm thickness
300 mm width X 50 mm depth X 1.6 mm thickness
450 mm width X 62.5 mm depth X 2.0 mm thickness
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "bends" (Galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.l. suspenders including G.l. bolts & nuts, etc. as required.
100 mm width X 50 mm depth X 1.6 mm thickness
150 mm width X 50 mm depth X 1.6 mm thickness
200 mm width X 50 mm depth X 1.6 mm thickness
300 mm width X 50 mm depth X 1.6 mm thickness
450 mm width X 62.5 mm depth X 2.0 mm thickness
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "Tee" (Galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.l. suspenders including G.l. bolts & nuts, etc. as required.
100 mm width X 50 mm depth X 1.6 mm thickness
150 mm width X 50 mm depth X 1.6 mm thickness
225 mm width X 50 mm depth X 1.6 mm thickness
300 mm width X 50 mm depth X 1.6 mm thickness
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "Cross member" (Galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.l. suspenders including G.l. bolts & nuts, etc as required.
100 mm width X 50 mm depth X 1.6 mm thickness
150 mm width X 50 mm depth X 1.6 mm thickness
225 mm width X 50 mm depth X 1.6 mm thickness
300 mm width X 50 mm depth X 1.6 mm thickness
450 mm width X 62.5 mm depth X 2.0 mm thickness
600 mm width X 62.5 mm depth X 2.0 mm thickness
Closed GI Cable trays: Supply & fixing of the following closed GI cable tray 1.6 mm wall thickness and with every 500 mm distance two numbers of 25mm knock out hole provision on both side, and closed tray clamped at every one metre distance, and smooth finishing for DATA cable application and including supply & fixing of 8mm dia threaded rod with washers, check nuts, anchor fasteners, etc. as directed by E.I.C.
300 mm width X 50 mm height with removable top cover sheet
150 mm width X 50 mm height with removable top cover sheet
GI box for Closed Cable Trays: Supply, fixing of junction box 1.6mm thick with top cover, adequate closed tray entry and conduit entry with knock out provision and unused area closed with suitable GI sheet and as per instructions of E.I.C.
320 mm X 320 mm x 60 mm size
175 mm X 175 mm x 60 mm size
Blank PVC (HMS) Conduits : Supply & installation of high mechanical stress (HMS) rigid PVC conduit having ISI marked IS 9537 Part - 3, including fixing accessories & hardware concealed /exposed in slab/wall or on 5mm. thick G.I. spacers fixed with no. 10 nettle fold wood screws with nylon plug complete with all conduit accessories 20 SWG G.I. Saddles, MS/PVC pull out boxes, MS/PVC junction boxes, couplers, bends binding wires etc. as per site condition & as per instructions of E-I-C and of following sizes :-
25 mm dia Blank PVC (HMS) Conduits
32 mm dia Blank PVC (HMS) Conduits
M. S. Boxes: Fabrication, supply and installation of M.S. supports/boxes as per specification.
MS Fabrication : Supply, fabrication and installation of supports using MS channel/ angle/ flat/MS rod hangers etc. including painting with two coats of primer and two coats of epoxy paint of approved shade as per instructions of EIC.
Supply, installation of GI pipe of B class of following sizes sleeves in beams/ column/ slab for passing electrical cables/conduit as per instruction of E-I-C.
50 mm dia GI pipe
100 mm dia GI pipe
Supply & laying of following size (dia) self lubricated DWC HDPE pipes in ground at a depth of 600mm, cutting of existing footpath, road, etc., sand bedding, laying of warning tape on top, temporary reinstatement back filling, dewatering if necessary consolidation, disposal of excess earth with in the radius of 500mm etc. or fixed on wall/coloumn/slab with 5mm thick M.S. flat/ GI spacer/angle/ support fixed with coach screws/ grouted in wall/ anchor fasteners 2mm thick GI fabricated saddle, all fixing accessories, etc. complete including painting of M.S. spacers/ angles all as per the attached work specifications and instructions of E-I-C.
90 mm dia (OD-90 mm & ID-76 mm nominal)
160 mm dia (OD-160 mm & ID-135 mm nominal)
300 mm outer dia (OD-300 mm & ID-260 mm nominal)
Excavation of earth with All types of soil including murram
Excavation of earth with Hard Rock
Supply and installtion of expanding firestop foam equivalent to Hilti CP 620 on both sides of wall, with minimum 2 hours fire rating when tested in accordance with UL 1479/ASTM-E 814, for horizontal openings in floors or slabs made of concrete/ masonry or Gypsum after passing service lines like cable trays or cables/cable bundles. The expanding foam expands seven times its volume to fill the cavity at the time of dispensing the material and shall fully cure within two minutes after dispensing. The product shall be age tested as per Dafstb and DIBT standards. The product shall provide water tightness when tested for W rating as per UL standards and shall carry test certificate for sound insualtion of 50 db when tested in accordance with ASTM E 90. The product volume shall be shall be minnimum 300 ml per cylinder. The product shall carry test certificate for mold resistance rating of 0 as determined by ASTM G21-96 and shall have a VOC content of approx. 1.3 g/l as per LEED 2009. The product shall be tested in accordance with IEC 60068-2-57:1999-11 (Environmental Testing) as per Part 2-57: Test for Vibration-Time-history method and VERTEQII for seismic zone 4. The system shall be UL listed & classified. The system shall be UL & FM approved.
Supply and installation of Fire stop mortar system equivalent to Hilti CP 636 , with minimum 2 hours fire rating when tested in accordance with UL 1479/ASTM-E 814 standards, for horizontal openings in floors or slabs after passing service lines like cables/cable bundles, cable trays etc. The mortar shall be a light weight cementitious product and shall carry test certificate in accordance with IEC 60068-2-57:1999-11 (Environmental Testing) as per Part 2-57: Test for Vibration-Time-history method and VERTEQII for seismic zone 4. The product shall be age tested as per Dafstb and DIBT standards. The product shall carry test certificate for mold resistance rating of 0 as determined by ASTM G21-96. The product shall be age tested as per Dafstb and DIBT standards.The system shall be UL listed. The gaps around inaccessible or complicated openings shall be sealed with exapnding firestop foam.
Supply and installatio of Acrylic Firestop Sealant equivalent to Hilti CP 606 in gaps between wall and slab made of concrete/masonary/gypsum on both sides of wall to provide minimum 2 hours fire rating when subject to the test conditions of UL 2079 standards. The product shall be age tested as per DafStb guidelines. The product shall be age tested as per Dafstb and DIBT standards.Sealant should provide sufficient MAF, water and gas tight seal. The product volume shall be shall be minnimum 310 ml per cylinder. Sealant shall also provide airborne sound transmission reduction (STC of 50) and shall be tested as per DIN 52210 for sound insulation. Sealant shall carry test certificate for mold resistance rating of 0 as determined by ASTM G21-96 and should have a VOC content of approx. 75 g/l as per LEED 2009. The sealant shall carry test certificate in accordance with IEC 60068-2-57:1999-11 (Environmental Testing) as per Part 2-57: Test for Vibration-Time-history method and VERTEQII for seismic zone 4. (310ml)
RACEWAYS & FLOOR JUNCTION BOX Supplying & laying under floor pregalvanised corrosion proof rectangular sheet steel cable trunking of 1.6 mm thick having with stand point load up to 1.33 Ton & free from seepage of concrete of screed water having following size of dimensions and No of compartments (W x D x T)
100mm x 38mm x 1.6 mm with One Compartments
225mm x 38mm x 1.6 mm with Three Compartment
300mm x 38mm x 1.6 mm with Three Compartments
[C] G.I. Junction cross over box for metal trunking with duct entry 25mm x 38mm size having epoxy powder coated trap lead with corrosion & rust free having load bearing capacity of 3.6 TONS with adjustable levelling screw of following size with required accessories.
150mm x 150mm x 60/75 mm depth
300mm x 300mm x 60/75 mm depth
450mm x 450mm x 60/75 mm depth
Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.
Insulating Mat : Supply and fixing in position of 'C' class ELASTOMER' 'insulating mat for protection to operators for working voltages upto 65 KV as per IS 15652 - 2006 of 2000 mm (W) as per instructions of EIC.
Supply and fixing in position of 'A' class ELASTOMER' 'insulating mat for protection to operators for working voltages upto 3.3 KV as per IS 15652 - 2006 of size 1000 mm (W) as per instructions of EIC.
Safety Equipment: Providing and fixing danger plates made of mild steel atleast 2 mm thick & vitreous enameled white on both sides and with inscriptions in single red colour on front side as required.
High voltage size 250 mm x 200 mm
Medium Voltage size 200 mm x 150 mm
Providing and fixing carbon di-oxide (CO2) type fire extinguishers conforming to IS 15683 and cylinders fully charged of 4.5kg capacity.
Supply and fixing of foam fire extinguishers, portable type 9 litres capacity ( IS 15683) hanged on wall with bracket complete as required.
Supply & fixing of ABC type Fire extinguisher (IS 15683) - 5 kg capacity
Supply and fixing safety instruction chart in three languages with necessary lamination mounted on wooden frame with 5 mm thick glass as required ( approx front area 1.20 sq.mt)
Supply and fixing of electric schematic as built drawing (A0 size) in AUTOGLO with Al frame & as per instructions of E-I-C
Supply & erection of canopy type MS structure made of 40 NB medium MS pipe as per IS 1239 grouted in 1:2:4 PCC foundation , 25 x 25 x 3 mm angle iron framework and 14 SWG GI sheet covering and providing 4 nos 9.5 litre capacity GI bucket painted in post office red colour with prior coat of red-oxide paint with written with white paint 'FIRE' and including filling with clean sand, complete as required & as per instructions of EIC.
Providing fire aid box as approved by St. John Ambulance Brigade/Indian Red Cross conforming to IS 2217-1963 including necessary wall mounting MS frame etc. as required.
Supply and fixing shock treatment chart in three languages with necessary lamination mounted on wooden frame with 5 mm thick glass as required ( approx front area 1.20 sq.mt)
Supply of pedestal type sign board for substation of size 1530 mm x 900 mm fabricated out of 50 mm x 50 mm x 5 mm angle including providing and fixing 900 mm x 600 mm x 1.6 mm MS sheet duly welded , painted and printing as desired and fixing in ground complete as required & as per instructions of EIC.
Supply & fixing of display board for sub-station of 5 mm perspex sheet including printing on the sheet etc and fixing the same on door/wall complete as required and as per the instructions of E-I-C.
Supply of artificial respirator as per Director General of Medical Supplies , Govt of India , required as per IE Rule no. 44
Supply of HT rubber gloves & gum boots of approved quality suitable for use at 33kV, confirming to relevant statutory regulations, IS as required & as per instructions of EIC.
Supply & fixing 'NO SMOKING' & RESTRICTED ZONE' 'AUTOGLO' sign boards 150 mm (H) x 400mm (W) in three 'language with Al. frame as required & instructions of EIC.
Supply and installing of Boom Barrier (6mts) with Telescopic Aluminium Boom with Reflectors, with required microprocessor control board and base plate, having an opening time of 3 seconds including the cost of extra accessories such as photocell, safety loop coil, push button, 2 sets of remoe reciever, suitable for operation with smart card reader controller (access control system) and installation charges complete. Notes: 1. It also includes Shop drawing, Material approval & 2 mockups for approval as per specifications and direction of the Architectural design. 2. Power & control cabling is included in the cost.
Construction of fly ash / AAC /kiln burnt clay brick masonry chambers of following dimensions for depth as mentioned below comprising of 230 mm thick brick masonry in cement mortar 1:4 over a bed of 150 mm thick cement concrete of grade 1:2:4 for foundation with 150 mm offset allround, including racking out joints & plastering in cement mortar 1:3, 20 mm thick both on internal and external surfaces, internal surfaces finished smooth with a floating coat of neat cement, Fixing (FRP/GRP coposite / DI / CI / SFRC/ RCC/ MS) Frame and cover of approved make all as per specifications and directions of the E.I.C. including dewatering the pit, if required till completion of the work all complete. Note: steps / foot rests / rungs will be mesured and paid under relavant item.
Chamber measuring 0.6 mtr. X 0.6 mtr. for depth of 600 mm (Clear internal dimension)
Chamber measuring 0.9 mtr. X 0.9 mtr. for an initial depth of 600 mm (Clear internal dimension)
Extra over above item no. 19.37.2 for additional depth of valve chamber beyond initial depth of 0.60 mtr. with steps / foot rests / rungs etc. all complete.
Chamber measuring 1.2 mtr. X 1.2 mtr. for an initial depth of 600 mm (Clear internal dimension)
Extra over above item no. 19.37.4 for additional depth of valve chamber beyond initial depth of 0.60 mtr. with steps / foot rests / rungs etc. all complete.
Providing & fixing precast approved brand FRP/GRP Composite Manhole covers as approved by Competant athority / E.I.C tested as per IS:1726, including cost of necessary hardware, 1:2:4 grade concrete for fixing frame, bed block (bearing course) and capping including necessary form work and CM 1:2 mortar for fixing the frame & for plastering exposed surfaces of concrete bed block (bearing course) and capping finished smooth with floating coat of neat cement etc., complete as per specifications, drawings and as directed by the E.I.C. Note: Shade and Colour and design pattern to be get approved from Engineer-in-Charge.
Square Heavy duty (Grade HD - 20 designation as per IS:1726/ C-250 as per EN124 or higher loading class) frame and cover size 600 x 600mm.
Square Heavy duty (Grade HD - 20 designation as per IS:1726/ C-250 as per EN124 or higher loading class) frame and cover size 900 x 900mm.
Providing and fixing Heavy duty SFRC type manhole cover conforming and tested as per IS:12592 of following size clear opening with frame and cover with provisions to match with surrounding finished level without any undulation for smooth running as approved and as specified having clear opening of given size and also covers have pick holes with a handle to lift manhole cover. It allows to fix with C:M 1:3 mortar with proper grading and on true line & level etc. complete as directed by EIC.
Square Heavy duty (Grade HD - 20 designation as per IS:12592) frame and cover size 1200 x 1200mm.
Providing and fixing copolymer polypropylene steel reinforced plastic Foot-rests / Steps of approved brand or eq. as per ASTM D - 4101 specification and moulded a 12 mm dia. IS - 1786 grade Fe - 415 steel reinforcing bar and in "U" shape having dimensions 263 x 168 mm and fixing in concrete / wall as shown in the drawing and as directed all complete.
Total of PART III-V - Miscellaneous
Description of Work / Item(s)
Amount
ABSTRACT FOR PART - IV : MECHANICAL WORKS
PART IV-A : HVAC SYSTEM
PART - IV-A-1 : WATER COOLED CHILLER PLANT ROOM
PART - IV-A-2 : AIR HANDLING UNITS AND TFA
PART - IV-A-3 : DX SYSTEM
PART - IV-A-4 : CHILLED WATER PIPE AND PIPE INSULATION
PART - IV-A-5 : CHILLED WATER VALVE ACESSORIES
PART - IV-A-6 : AIR DISTRIBUTION SYSTEM
PART - IV-A-7 : VENTILATION SYSTEM
PART - IV-A-8 : VRF SYSTEM
PART - IV-A-9 : CIVIL SUPPORT STRUCTURE
TOTAL OF PART IV-A : HVAC SYSTEM
PART IV-B : HVAC BUILDING MANAGEMENT SYSTEM
PART - IV-B-1 : BMS SERVER / WORK STATION COMPUTER / PRINTER
PART - IV-B-2 : BMS SOFTWARES / ENERGY MANAGEMENT
PART - IV-B-3 : IP BASED 3RD PARTY INTEGRATOR
PART - IV-B-4 : DDC CONTROLLERS
PART - IV-B-5 : SENSORS & FIELD DEVICES
PART - IV-B-6 : NETWORK SWITCH
PART - IV-B-7 : CABLES & ACCESSORIES FOR BMS
TOTAL OF PART IV-B (HVAC BMS SYSTEM)
PART IV-C : FIREFIGHTING SYSTEM
PART - IV-C-1 : FIRE EXTINGUISHERS AND SIGNAGES
PART - IV-C-2 : FIRE RISER & PIPING SYSTEM
PART - IV-C-3 : TERRACE PUMP & ACCESSORIES
PART - IV-C-4 : SPRINKLER & RELATED ACCESSORIES
PART - IV-C-5 : PIPES AND RELATED ACCESSORIES
PART - IV-C-6 : FIRE PUMP & RELATED ACCESSORIES
PART - IV-C-7 : HIGH VELOCITY WATER SPRAY SYSTEM FOR 2500 KVA TRANSFORMER.
PART - IV-C-8 : CIVIL ITEMS - FFTG VALVE CHAMBER
TOTAL OF PART IV-C : FOREFIGHTING SYSTEM
Description of Work / Item(s)
Amount
PART IV : MECHANICAL WORKS
PART IV-A : HVAC SYSTEM
PART IV-A-1 : WATER COOLED CHILLER PLANT ROOM
WATER COOLED SCREW CHILLERS Supply, installation, lifting-shifting at site, testing & commissioning and field performance of water cooled screw type water chilling machines with soft starter having following designed capacity comprising of hermetic/semi hermetic twin screw type twin or multi compressors , with refrigerant circuits, step less capacity control, direct driven motor with class 'F' insulation suitable for operation on 415 volts ±10%, 50 Hz, A.C. supply, suitable for operation on refrigerant R-134a or equivalent green CFC and HCFC free refrigerant with necessary drive arrangement, safety switches, forced feed lubrication system etc. complete as per specifications and as required. Chiller shall be capable for running at low load condition till 25%. Chillers shall have AHRI / Eurovent certification.
Chiller should be supplied with unit mounted Starter cum control panel. Chiller shall also be provided with the following:- (i) Matching shell and tube water cooled condenser of C.S. shell and integrally finned copper tubes having multi passes.- Supplier to provide matching flanges. (ii) Matching shell and tube flooded type chiller for screw type units of CS shell and copper tubes having max. Multi passes - Supplier to provide matching flanges. (iii) Refrigerant piping fittings, valves, Expansion valves and accessories to inter connect compressor, condenser, chiller and expansion valve etc. complete as per specification as required.
Design conditions: Chiller Capacity : 400 TR (2 Working +1 SB) at Duty Point Condition Condenser water Temp diff. : 5˚C Chilled water IN : 11.7˚C Chilled water OUT : 6.7˚C Fouling factor evaporator : 0.0001 FPS (hr ft2 ⁰F/Btu) Fouling factor condenser : 0.00025 FPS (hr ft2 ⁰F/Btu) Chilled Water Flow Rate : 1067 USGPM Cooling Water Flow Rate : 1350 USGPM Max Pressure Drop Across Evaporator & Condensor : 12 mt COP @ AHRI conditions shall not be less than 5.9 IPLV @ AHRI conditions shall minimum 10 IKW/TR @ design conditions shall not exceed 0.65 Refrigerant : R134a / Equivalent Green CFC & HCFC Free Chiller factory test to be required both at duty point & AHRI conditions. Test shall be performed at 4 point - 25%, 50%, 75% and 100%
Chiller Plant manager
Supply, Installation, Testing and Commissioning of intelligent chiller plant manager cum Optimizer suitable for All Variable system including LCD display, PLC controller with all instrument, sensors, accessories and interconnecting control and power cabling etc, supporting and controlling the water cooled chiller plant. The programmable logic controller shall be specifically designed to control 4 water cooled Screw chillers , 4 cooling tower fans, 4 cooling tower isolation valves, 4 condenser pumps, 4 fixed speed primary pumps, 4 Variable Speed Secondary Pumps , 4 chiller isolation valves, 1 no. 2 way modulating valve on by pass line to maintain minimum flow requirement of chillers with the help of flow meter, 1 zone demand sensor (DP + temp sensor both each ), Pressurization Unit , Chemical dozing plant and Water level switches in cooling towers , BTU meter , Cooling water make up water flow meter. The CPM controller should be capable of sequencing, staging, scheduling, load sharing between chillers and optimization along with chilled water reset & Pump pressure optimization.The CPM shall have cooling tower optimization software .
Mono Rail Mechanical Crane with Chain Pully Block Supply, erection, testing and commissioning of single girder type mechanically operated operated crane with chain pully operated hoist, geared trolley, railtrack, moving or cross girder, brake, safety device, locking arrangement and all other required accessories as per data sheet and specification.
Capacity : 2.0 Ton Span : 12.5 mtrs.(min) Lift : 5.00 mtrs. (min) Bay length: 25 mtrs.
PRIMARY CHW PUMP Chilled Water Pumping System with accessories dedicated Primary Chilled Water Pump
Supply of factory designed, built, tested & assembly skid mounted VIL(Vertical Inline) Long Coupled Pumps. Skid shall be comprising of 4 nos pumps (3 Working +1 standby/Assist) as per the following description and each pump with Star Delta Starter, will have 1 Butterfly valve, 1 Suction Guide, 1 Tripple duty valve , 2 pressure gauges. Pipe work,asessories, pumps shall be suitable for PN-16 rating mouted in a single skid from OEM factory. In case the OEM does not supply the skid comprising all the above mentioned items, the same shall have to be assembled at site comprising of all the items and quantities as mentioned above. In either case the makes of all the material shall be from the list of preffered maked mentioned in the tender. Vertical inline split coupled pumps, complete with IE3 motor, drain valves and other accessories. Minimum efficiency of pump shall be 75%. . Hydrostatic pressiure testing of the complete pumping package skid to be done at factory. The factory built skid should be tested as a single unit along with individual pump tested before assembly at OEM works to ensure desired pumping performance. It should be designed that the complete unit is balanced & free from vibrations with necessary vibration isolations whereever required. Suction guide, Triple duty valve to be supplied by pump manufacturer for unit responsibility.
The unit shall be rested on engineered spring vibration isolator. The chilled water pumps shall include thermal insulation & cladding with Corrosion resistant painted MS factory-fabricated base frame. The unit shall have suitable capacity induction motor with class 'F' insulation suitable for operation on 415 volts ±10%, 50 Hz, A.C. supply. The given head are an indicative head requriement , how ever contractor to submit the head calculation along with the technical data sheet before supply ( with out andditional cost).
Primary Chilled Water Pump = 1067 USGPM ( For 400 TR Chiller ) Total Dynamic Head = 12 M WC 1 skid set = ( 3 working + 1 SB/A)
CONDENSER PUMP Supply of factory designed, built, tested & assembly skid mounted VIL(Vertical Inline) Long Coupled Pumps. Skid shall be comprising of 4 nos pumps (3 Working +1 standby/Assist) as per the following description and each pump with Star Delta Starter, will have 1 Butterfly valve, 1 Suction Guide, 1 Tripple duty valve , 2 pressure gauges. Pipe work,asessories, pumps shall be suitable for PN-16 rating mouted in a single skid from OEM factory. In case the OEM does not supply the skid comprising all the above mentioned items, the same shall have to be assembled at site comprising of all the items and quantities as mentioned above. In either case the makes of all the material shall be from the list of preffered maked mentioned in the tender. Vertical inline split coupled pumps, complete with IE3 motor, drain valves and other accessories. Minimum efficiency of pump shall be 75%. . Hydrostatic pressiure testing of the complete pumping package skid to be done at factory. The factory built skid should be tested as a single unit along with individual pump tested before assembly at OEM works to ensure desired pumping performance.
Condenser Pump = 1350 USGPM ( For 400 TR Chiller ) Total Dynamic Head = 25 M WC Pumps shall be checked for Parallel Pumping Operation 1 skid set = ( 3 working + 1 SB/A)
SECONDARY CHW PUMP Variable Speed Pumping System with accessories dedicated for Secondary Chilled Water Pump & Cooling Water Pump
Supply of factory designed, built, tested & assembly skid mounted VIL(Vertical Inline) Long Coupled Pumps. Skid shall be comprising of 4 nos pumps (3 Working +1 standby/Assist) as per the following description and each pump with VFD starter, will have 1 Butterfly valve, 1 Suction Guide, 1 Tripple duty valve , 2 pressure gauges. Pipe work,asessories, pumps shall be suitable for PN-16 rating mouted in a single skid from OEM factory. In case the OEM does not supply the skid comprising all the above mentioned items, the same shall have to be assembled at site comprising of all the items and quantities as mentioned above. In either case the makes of all the material shall be from the list of preffered maked mentioned in the tender. Vertical inline split coupled pumps, complete with IE3 motor, drain valves and other accessories. Minimum efficiency of pump shall be 75%. . Hydrostatic pressiure testing of the complete pumping package skid to be done at factory. The factory built skid should be tested as a single unit along with individual pump tested before assembly at OEM works to ensure desired pumping performance. It should be designed that the complete unit is balanced & free from vibrations with necessary vibration isolations whereever required. Suction guide, Triple duty valve to be supplied by pump manufacturer for unit responsibility.
The unit shall be rested on engineered spring vibration isolator. The chilled water pumps shall include thermal insulation & cladding with Corrosion resistant painted MS factory-fabricated base frame. The unit shall have suitable capacity induction motor with class 'F' insulation suitable for operation on 415 volts ±10%, 50 Hz, A.C. supply. Design basis for variable pumping shall be as per design specifications enclosed separately VFD protection shall be suitable for indoor applications, shall be offerd as Motor mounted or as an integratl part of skid .Variable pump controller offered should not be housed in any VFD and shall be separately housed in a separate panel mounted on the skid package offered. Single point power supply shall be made available to each pump skid from the plant room ele panel.
Microprocessor based pump logic controller pump controller shall be IP-55 suitable for parallel pumping software duly downloaded, 02 No. Differential Pressure Sensor / Transmitters or sensorless logic, interfacing amongst all components and compatibility of I/O signals, BMS compatible etc complete with other accessories as required. It should be complete as per manufacturer's Specifications. VFD shall be capable to operate on Sensorless Control application along wth controller or alternately need to supply 2 nos DPT for signal to microprocessor. Controller should have parallel pump logic to operate all set of the pumps with the following features: Parallel pump operation for power savings. - Controller shall control pump VFD's as per building load variation. The given head are an indicative head requriement , how ever contractor to submit the head calculation along with the technical data sheet before supply ( with out andditional cost).
Secondary Chilled Water Pump = 1994 USGPM ( For Academic / Lab / Canteen Buildings ) Total Dynamic Head = 40 M WC 1 skid set = ( 3 working + 1 SB/A)
Cooling Tower Make-up Tank Pump Supply, installation, testing & commissioning of Submersible Non Clog, single stage, single entry pumps connected to TEFC submersible motor for 415 + 10% volts, 3 phase, 50 cycles A.C. power supply with mechanical seal, pump connector unit with rubber diaphragm and bend, vertical discharge pipe. The pump shall be provided with a lifting devise of pull chain/guide rail. (Pumps suitable with C.I. body, SS304 shaft, SS impeller). Panel mounted microprocessor based multi pump controller with large graphical display with VGA 240 x 320 pixels and IP 55 enclosure, diodes to indicate pump ready, earthing, pump running and fault condition, Cascade Operation. Each incomer and Outgoing feeder should be capable for protection against Overload, Short Circuit and Phase reversal condition and shall be capable to communicate with other controllers following. The PLC shall support MODBUS-IP communication for its compatability to intergrate with 3rd party BAS system. Controller shall authorise Read/Write command via BMS.All alarms should be displayed in the controller. System should be equipped with dry running protection. Indication of all type of faults / on-off status / electrical parameters shall be available on panel and central IBMS monitors.
On-off operation for all pumps shall be available on BMS system.Scope shall also include supply, laying, termination of control and power cables of adequate size and arrangemnt of cable trayfrom pump to control panel etc. to complete the job. Electronic type low, Medium & High water level controller with LED panel to operate pump (necessary contacts along with minimum one PLC operated spare contacts required),level controller with operational mode as one pump working at Medium level, both pumps at High level with a hooter alarm and cut off at Low level complete the job. Mounting Height (Low Level ): (Sump) Mounting Height (Medium Level) : (Sump) Mounting Height (Hight Level ): (Sump) with probe & all control wiring from Pump room Panel to Sump to operate the system automatic/manual & shall prevent the pump from dry running. Scope shall also include power and control cable of required size, termination, cable tray from Pump to Control panel, control cable as whereever required etc. complete the job. Set of accessories such as CPVC SCH 80 headers of discharge for (working and Standby pump assembly) , Gun Metal Isolation valves, Gun Metal non return valves, pressure gauge with Isolation Valve of PN 10 etc. complete the job.
Capacity per pump - 10.0 m3/hour, Head -20 mt, 1 Set = 2 Nos. Pump (1 Working + 1 Standby - cascade operation).
Water flow rate : 1350 USGPM ( For 400 TR Chiller ) Water Temp. at INLET : 37⁰C Leaving Water temp. : 32⁰C Design ambient wet bulb temp : 29.9⁰C (85.8⁰F) (To be designed for extreme WB temp. for Hyderabad) Cooling tower approach required : 2.8⁰C (Not exceeding 3⁰C )
Closed Expansion Tank Supply, installation, testing and commissioning The closed expansion tank will be of M.S. construction with interchangeable Synthetic Rubber membrane. The expansion tank shall be complete with safety relief valve and pressure gauge. The tank will be of pressure rating to suit the system pressure and will be sized to adequately compensate for water expansion due to operating temperature variations. For chilled water application, it will be insulated with 50 mm thick insulation to the specifications and cladded with 26G-aluminum cladding.
Size: 2000 Liter ( Apx. )
TOTAL OF PART IV-A-1 : WATER COOLED CHILLER PLANT ROOM
PART IV-A-2 : AIR HANDLING UNITS AND TFA
AIR HANDLING UNIT (RECIRCULATING TYPE AHU) a) Supply, Installation, testing & Commissioning of Factory built Air Handling Units (AHUs). AHU shall be provided with mixing box , filter section , coil section , humidifier section , fan section , Fresh air connection with damper, limit switch, drain connections, stainless steel (18G) drain pan with Nitrile rubber insulation 19 mm thick, auto purge valve, drain valve wherever required. etc. conforming to specifications with all the necessary mounting accessories as required for complete installation include Lifting, shifting, assembling & positioning of the equipment comprising of the following and complete as per specification/drawings and as directed by Engineer In Charge. b). Unit must in Double skin type with Extruded Aluminium profile having thermal break and complete with Plug fan with VFD, min 48±2 mm thick panels consisting of GI casing of thickness 0.8mm pre-plasticized outside & 0.8 mm non coated inside layer with factory injected PUF (Density-40±2 kg/m3) between them.
f). Filter sections with velocity less than equal to 500 FPM. - MERV 8 (confirming to standard ASHRAE 52.2) - For AHU & CSU - MERV 13 (confirming to standard ASHRAE 52.2) - For AHU (for Labs AHU only 28500 CFM 44 TR AHU ) - Commissioning Filters (Disposable) also to be provided. g). Minimum 6 row deep cooling coil & Electrical Heating Coil suitable for 2 kw x 5 Nos. (Applicable for Lab area) Coil face velocity shall be kept 500 FPM, Coil shall have hydrophilic coating & SS End Plates: - Material of Tube - Copper, - Chilled Water inlet/ outlet temperature - 6.7°C / 11.7°C h). AHU shall have provision for the following; - DP switch across all filters, both Coil & Fan Section.. - Return air temperature & RH sensor. (Note:- Contractor shall coordinate with IBMS contractor for necessaries provision to be made in AHU's.)
i). AHU shall have heater element comprise of Terminal Box containing Terminations and wiring , Heating element of SS or Alloy Sheath to prevent Oxidation & corrosion , Heating element to have tubular element along with finned element for increased heat transfer area. This heater shall be mounted with in the AHU or supply air duct with nut bolt flange arrangement. Heater on off and modulation controller shall housed the thyristor driver along with primary safety thermostat, on / off / trip indicator light , Air state to control operation during no air flow , and AHU starter interlocking arrangement. j). Fan Static Indicated below are tentative , Contractor shall submit Fan static calculations based on approved shop drawings & as per actual site condition before ordering the unit. Any rise in static required shall be offer by contractor without any additional cost. k). AHU shall be designed to ensure NC 35 in the Lab , hence AHU unit noise level to confirm accordingly.
28500 CFM / 44.0 TR / 50mm ESP (AHU with MERV 8 and MERV 13 filter as per (f))
10000 CFM / 30.5 TR / 30mm ESP (AHU with MERV 8 filter only as per (f))
9000 CFM / 22.5 TR / 30mm ESP (AHU with MERV 8 filter only as per (f))
UVGI SYSTEM FOR EACH FMAHU (For Lab Areas) SITC of AHU coil mounted UVGI system shall be designed for effective disinfection and provide a UV dose of not less than 611 µJ/cm2 in a single pass to achieve kill rate at least 90% of virus/bacteria susceptible to this dose. The computer simulation provided by the manufacturer will state the UV dose imparted to the airstream and the irradiation profile on the AHU coil. The UV-C should be of 254 nm wavelength and no ozone shall be produced as a by-product. The lamps should be of High Output type (800 mA each). These lamps should be specially designed to be used in low temperature applications and shall provide a rated average life of 12,000 hours. The reflector shall be built from an high UV reflective aluminium material capable of withstanding air velocities of up to 2000 ft/min without excessive noise, wobble, or vibration. The vendor shall supply the test certificate for each unit showing conformance to the technical specifications.
Each UVGI module shall be equipped with a dish antenna shaped aluminium parabolic reflector with high spectral reflectivity. This ensures no stray UV-C intensity is leaked onto surfaces and parts located behind the UVGI lamp, which can result in rapid degradation of the wirings, linings, belts, and other plastic/rubber parts. The MOC of each lamp should be High Purity Fused Quartz. The ballasts must be integrated onto the module in a sealed aluminium enclosure to protect against moisture and humidity present in the AHU or duct and be certified for installation inside the duct along with the emitter. The ballast shall be installed inside AHU only to enhance ballast life & performance. The device submitted shall be classified by UL (Underwriters Laboratories) as an Air Duct Mounted Accessory (ABQK) and meet the UL Standards 1995 (Heating and Cooling Equipment) and 2043 (Fire Test for Heat and Visible Smoke Release). The appropriate UL mark along with manufacturers UL file number shall be permanently marked on the exterior of the product.
28500 CFM / 44.0 TR / 30mm ESP
CEILING SUSPENDED AIR HANDLING UNIT (RECIRCULATING TYPE AHU) a) Supply, Installation, testing & Commissioning of Factory built Air Handling Units (AHUs) with Ceiling mount arrangements. AHU shall be provided with filter section , coil section , fan section connection with damper, limit switch, drain connections, stainless steel (18G) drain pan with Nitrile rubber insulation 19 mm thick, auto purge valve, drain valve wherever required. etc. conforming to specifications with all the necessary mounting accessories as required for complete installation include Lifting, shifting, assembling & positioning of the equipment comprising of the following and complete as per specification/drawings and as directed by Engineer In Charge. b). Unit must in Double skin type with Extruded Aluminium profile and complete with DIDW Direct Drive Fan, min 48±2 mm thick panels consisting of GI casing of thickness 0.8mm pre-plasticized outside & 0.8 mm non coated inside layer with factory injected PUF (Density-40±2 kg/m3) between them.
g). Minimum 6 row deep cooling coil. Coil face velocity shall be kept 500 FPM, Coil shall have hydrophilic coating & SS End Plates: - Material of Tube - Copper, - Chilled Water inlet/ outlet temperature - 6.7°C / 11.7°C h). AHU shall have provision for the following; - DP switch across all filters & both Coil. - Return air temperature & RH sensor. (Note:- Contractor shall coordinate with IBMS contractor for necessaries provision to be made in AHU's.) i). Fan Static Indicated below are tentative, Contractor shall submit Fan static calculations based on approved shop drawings & as per actual site condition before ordering the unit. Any rise in static required shall be offer by contractor without any additional cost.
1200 CFM / 3.0 TR / 30mm ESP
1800 CFM / 4.0 TR / 30mm ESP
2000 CFM / 5.0 TR / 30mm ESP
4500 CFM / 7.5 TR / 30mm ESP
1000 CFM / 3.0 TR / 30mm ESP
1400 CFM / 3.0 TR / 30mm ESP
2800 CFM / 6.0 TR / 30mm ESP
3200 CFM / 6.5 TR / 30mm ESP
3800 CFM / 8.0 TR / 30mm ESP
6000 CFM / 12.0 TR / 30mm ESP
Units shall be supplied along with 4'' LCD display thermostat / controller of proportional type, power supply 220±6% VAC with output control signal of 0-10 VDC and output power supply for 24 VAC for motoric modulating actuator. Thermostat shall have intelligent ΔT manager to maintain set 5 Deg C ΔT of chilled water. It shall be able to monitor outlet chilled water temperature 11.7 Deg. C and inlet chilled water temperature 6.7 Deg. C and maintain set 5 Deg C ΔT by modulating flow of water. The controller will be BMS compatible with all required open protocol and required licence software. Units shall be BMS compatible with Modbus protocol Units shall have provision for fresh air intake
400 CFM / 1.0 TR
600 CFM / 1.5 TR
800CFM / 2.0TR
Units shall be supplied along with 4'' LCD display thermostat / controller of proportional type, power supply 220±6% VAC with output control signal of 0-10 VDC and ouput power supply for 24 VAC for motoric moulating actuator. Thermostat shall have intelligent ΔT manager to maintain set 5 Deg C ΔT of chilled water. It shall be able to monitor outlet chilled water temperature 11.7 Deg. C and inlet chilled water temperature 6.7 Deg. C and maintain set 5 Deg C ΔT by modulating flow of water. The controller will be BMS compatible with all required open protocol and requried licence softares.
300 CFM / 1.0 TR
450 CFM / 1.5 TR
Units shall be supplied along with 4'' LCD display thermostat / controller of proportional type, power supply 220±6% VAC with output control signal of 0-10 VDC and ouput power supply for 24 VAC for motoric moulating actuator. Thermostat shall have intelligent ΔT manager to maintain set 5 Deg C ΔT of chilled water. It shall be able to monitor outlet chilled water temperature 11.7 Deg. C and inlet chilled water temperature 6.7 Deg. C and maintain set 5 Deg C ΔT by modulating flow of water. The controller will be BMS compatible with all required open protocol and requried licence softares.
300 CFM / 1.0 TR
450 CFM / 1.5 TR
Valve Package for Fan Coil Unit SITC of factory fitted (Preferably) and tested complete valve package assembly for Fan Coil Units comprising of Pressure independent balancing and control valve with motoric modulating Actuator (0-10Volt DC signal) and 2nos. isolating valve at inlet and return line with 1no. strainer at inlet line, in chilled water lines and with stainless steel auxiliary drain pan at each unit.
Valve Package Assembly 2 Way Valve 20 mm (for 1.0 / 1.5 / 2.0 Tr Units)
TREATED FRESH AIR UNIT a). Supply, Installation, testing & Commissioning of Factory built Outdoor mounted Treated Fresh Air Unit with thermal break profile and complete with Plug fan. Unit Shall in double skin construction, comprising of supply air section & fresh air section with Damper, chilled water coil section, filter section , limit switch, drain connections, purge section. Supply air Al. dampers, stainless steel (18G) drain pan with Nitrile rubber insulation 19 mm thick, auto purge valve, drain valve wherever required for complete installation include Lifting, shifting, assembling & positioning of the equipment comprising of the following and complete as per specification/drawings and as directed by Engineer In Charge. b). Unit must in Double skin type with Extruded Aluminium profile having thermal break and complete with DIDW Direct Drive Fan, min 48±2 mm thick panels consisting of GI casing of thickness 0.8mm pre-plasticized outside & 1.0 mm non coated inside layer with factory injected PUF (density-40±2 kg/m3) between them.
f). Filter sections with velocity less than equal to 500 FPM. - MERV 8 (confirming to standard ASHRAE 52.2) - Commissioning Filters (Disposable) also to be provided. g). Minimum 8 row deep cooling coil. Coil face velocity shall be kept 500 FPM, Coil shall have hydrophilic coating & SS End Plates: - Material of Tube - Copper, - Chilled Water inlet/ outlet temperature - 6.7°C / 11.7°C h). Unit shall have provision for the following sensors; - DP switch across all filters, both Coil & Fan Section. - Temperature sensor (Note:- Contractor shall coordinate with IBMS contractor for necessaries provision to be made in TFA) i). Fan Static Indicated below are tentative , Contractor shall submit Fan static calculations based on approved shop drawings before ordering the unit. Any rise in static required shall be offer by contractor without any additional cost.
1850 CFM / 9.5 TR / 30 ESP (Fan without VFD)
1600 CFM / 8.0 TR / 30 ESP (Fan without VFD)
3330 CFM / 16.5 TR / 30 ESP (Fan without VFD)
6025 CFM / 30.0 TR / 30 ESP (Fan with VFD)
7600 CFM / 38.0 TR / 30 ESP (Fan with VFD)
HRU - TFA UNITS WITH CHW COIL a). Supply, fixing and commissioning of Floor Mounted Type Compact Double skin construction Energy / Heat recovery unit with ARI Certified Energy/Heat Recovery Heat Transfer Media suitable for accommodating two parallel air streams rated for following duty CFM average and as per the specifications and working conditions b). Design shall be based on minimum 75% Recovery efficiency and for the Ambient conditions for Hyderabad weather data; FA Temp is 37.3 deg C, RA conditions of 26 deg C DBT/55% Rh and Average air quantity as specified below
g). Filter sections with velocity less than equal to 500 FPM. - MERV 8 (confirming to standard ASHRAE 52.2) - Commissioning Filters (Disposable) also to be provided. h). Minimum 6 row deep cooling coil, Coil face velocity shall be kept 500 FPM, Coil shall have hydrophilic coating & SS End Plates: - Material of Tube - Copper, - Chilled Water inlet/ outlet temperature - 6.7°C / 11.7°C i). TFA-HRU shall have provision for the following; - DP switch across all filters & both Coil. - Return air temperature & RH sensor. (Note:- Contractor shall coordinate with IBMS contractor for necessaries provision to be made in HRU's.) j). Fan Static Indicated below are tentative , Contractor shall submit Fan static calculations based on approved shop drawings & as per actual site condition before ordering the unit. Any rise in static required shall be offer by contractor without any additional cost.
k). Return/Fresh air intake Section High Performance HRW Total Energy Recovery Wheel in Aluminium, coated with Molecular Sieve 3Å* for limiting cross contamination Drain pan insulated with 19 mm close cells high density insulation to prevent condensation of moisture on exteriors or interiors of the unit.
F.A.- 2500 CFM / 12.5 TR , E.A.- 2400 CFM, 30 mm ESP
AHU Room Thermostatic Controller
Supply / Installation / Testing and Commissioning of BMS Communicable Thermostatic Decorative LCD Display Room Controller with require cable / control wire and conduit as actual from AHUs
TOTAL OF PART IV-A-2 : AIR HANDLING UNITS AND TFA
PART IV-A-3 : DX SYSTEM
DX Fan Coil AC Unit Supply, Installation, testing & Commissioning of (nominal capacity) Air-cooled inverter type split type AC unit along with indoor/outdoor units, refrigerent type R-410a or R-32, controls suitable to operate on 230 Volts 50 Hz AC supply etc. complete as required including voltage stabiliser of suitable rating to give constant output of 230V for input range of 180 V to 260 V with time delay, high/low cut off, meter to read input and output voltages, ON/OFF switches etc. as required. Quoted price shall include cost of wireless remote controller, cooling thermostat, refrigerant filling. Unit shall be provided with auto timer setting. As per technical specifications with all the necessary mounting accessories as required for complete installation. The noise level of HI- Wall indoor unit shall not be more than 35 dB (A) at 1.5 meter distance. As per specification/drawings and as directed by Engineer In Charge. (Refrigerant piping shall be paid separately )
2.5 TR Fan Coil type AC Unit with 6mm ESP
2.0 TR Fan Coil type AC Unit with 6mm ESP
1.0 TR Fan Coil type AC Unit with 6mm ESP
DX Inverter Type Hiwall type AC unit Supply, Installation, testing & Commissioning of minimum 4 star, BEE rating (nominal capacity) Air-cooled inverter type split type AC unit along with indoor/outdoor units, refrigerent type R-410a or R-32, controls suitable to operate on 230 Volts 50 Hz AC supply etc. complete as required including voltage stabiliser of suitable rating to give constant output of 230V for input range of 180 V to 260 V with time delay, high/low cut off, meter to read input and output voltages, ON/OFF switches etc. as required. Quoted price shall include cost of wireless remote controller, cooling thermostat, refrigerant filling. Unit shall be provided with auto timer setting. As per technical specifications with all the necessary mounting accessories as required for complete installation. The noise level of HI- Wall indoor unit shall not be more than 35 dB (A) at 1.5 meter distance. As per specification/drawings and as directed by Engineer In Charge. (Refrigerant piping shall be paid separately )
1.0 TR Hi Wall Split AC Unit (Min 4 Star)
2.0 TR Hi Wall Split AC Unit (Min 4 Star)
1.5 TR Hi Wall Split AC Unit (Min 4 Star)
Refrigeration Piping, Control Cabling & Insulation of Air Conditioning Units SITC of Seamless 18G Copper piping of following size duly insulated with 19mm thk. Nitrile Rubber Insulation covered with self bonded UV resistant canvass cloth ( As per Specified with K Value of 0.027-0.029 K Cal/Hr.M Deg C at 0-16 Deg C) . Refrigeration piping will have to be taken in the piping rack / engineered Support as specified individually connecting to all indoor units for the respective floors. Even necessary supports, fittings, valves & ref. joints where ever required will be included. The said quantities are single line measurement between indoor unit and out door unit irrespective of number of refrigerant circuit in AC unit, i.e liquid line and gas line jointly considered as 1 unit.
For 2.5 TR Unit
For 2.0 TR Unit
For 1.5 TR Unit
For 1.0 TR Unit
TOTAL OF PART IV-A-3 : DX SYSTEM
PART IV-A-4 : CHILLED WATER PIPE AND PIPE INSULATION
Pre Insulated Pipe ( For Infrastructure ) The pre-insulated piping shall be suitable for under-ground application for supplying chilled water in the range of 5.5 Deg C to 12.5 Deg C. The Service Pipe material shall be MS ERW, conforming to IS 1239 (Part 1) : 2004 Class C (up to 150mm) & IS 3589 :2001 MS ERW (Above 150mm). Pre-Insulated Pipes & Fittings shall be manufactured at factory with a built in twisted-pair design leak detection cables consisting of two insulated 1.5mm2 insulated copper wires. The system shall be capable of detecting & locating multiple leaks & identifying the location of breaks and shorts on the cable.
The service pipe insulation shall be rigid, closed cell polyurethane insulation with the minimum properties listed below. The polyurethane insulation properties shall be in accordance with ASTM C1029, Type III. For pipe sizes 80 mm and larger, the insulation shall be applied by spraying the foam directly onto the pipe and extruding the HDPE jacket directly on top of the foam having wind-down end seal (water stop seal) of same jacket thk. Metal diffusion barrier shall be applied between the outer surface of the insulation and the jacketing material so as to eliminate the effect of reduced insulation properties to aging. The insulation shall be bonded to the service pipe & HDPE jacket and shall meet the shear strength requirement as per EN253. For pipe sizes up to and including 65 mm the insulation can be applied by injecting the polyurethane foam into the annulus between the service pipe and a pre-extruded HDPE casing. The Insulation shall have minimum density 48 kg/m3, minimum compressive strength of 300 kPa, max thermal conductivity of 0.023 W/mk at 25 Deg C, 88% min closed cell content & water absorption less than 10%. Insulation & HDPE Jacket thickness as mentioned. Note : Bare pipe shall be ispected at factory before insulation casted.
350 mm NB / 6 mm Pipe wall Thk / 50 mm PUF / 3 mm HDPE Thk
300 mm NB / 6 mm Pipe wall Thk / 50 mm PUF / 3 mm HDPE Thk
250 mm NB / 6 mm Pipe wall Thk / 50 mm PUF / 3 mm HDPE Thk
200 mm NB / 6 mm Pipe wall Thk / 50 mm PUF / 3 mm HDPE Thk
150 mm NB / 5.4 mm Pipe wall Thk / 50 mm PUF / 3 mm HDPE Thk
125 mm NB / 5.4 mm Pipe wall Thk / 50 mm PUF / 3 mm HDPE Thk
100 mm NB / 5.4 mm Pipe wall Thk / 50 mm PUF / 3 mm HDPE Thk
INSULATED CHILLED WATER PIPING (Nitrile rubber insulation) (Within the Building) Supplying, laying fixing, testing and commissioning of following nominal sizes of chilled water piping inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with following closed cell elastomeric nitrile rubber of minimum 45 Kg / cum density, (µ value should grater than 7000) thermal conductivity 0.037 W/MK or better at 20 deg mean temperature class O insulation applied by suitable adhesive complete including repairing of damage to building etc. as per specifications and as required complete in all respect Note: The Pipes of sizes 150mm & below shall be M.S. 'C' class as per IS 1239 and pipes size above 150mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above.
350mm NB (32 mm Thick Insulation)
250 mm NB (32 mm Thick Insulation)
200mm NB (32 mm Thick Insulation)
150mm NB (32 mm Thick Insulation)
125 mm NB (32 mm Thick Insulation)
100 mm NB (32 mm Thick Insulation)
80 mm NB (32 mm Thick Insulation)
65 mm NB (32 mm Thick Insulation)
50 mm NB (32 mm Thick Insulation)
40 mm NB (32 mm Thick Insulation)
32 mm NB (19 mm Thick Insulation)
25 mm NB (19 mm Thick Insulation)
CONDENSER WATER PIPING WITHOUT INSULATION Supplying, fixing, testing and commissioning of condenser water pipes of following sizes of MS 'C' class along with necessary. clamps, vibration isolators and fittings such as bends,tees etc.but excluding valves, strainers, gauges etc. adequately supported on rigid supports duly painted/buried in ground excavation and refilling etc as per specification and as required complete in all respect. Note:-The Pipes size 150mm & below shall be M.S. 'C' class as per IS: 1239 and pipes size above 150mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. And from minimum 7mm thick MS sheet for pipes of 400 mm dia and above.
FRP Coating on Cooling Water Pipe Supply , applying lining for the cooling water pipe. The pipe shall be applied with paint and FRP Coating for weather protection
DRAIN PIPING : Providing and Fixing Hard CPVC drain water piping with fittings, support and insulated with 9mm thick closed cell elastomeric nitrile rubber insulation with ASTM E84 25/50 rated - where Flame Spread Index is 25 and Smoke Developed Index is 50, UL94(VO,HB) Passed ,GRIHA(V.3 criterion:14; V.2015 criterion: 8) certified and ASHRAE 90.1, NFPA 90A/NFPA 90B standards compliant Anti Microbial Closed Cell Nitrile Rubber with company bonded GC sheet of 7 mils/200 gsm having K value of 0.036 w/m.k at 24 Deg C with temp range of (-)50 to 105 Deg C. Water Vapor Permeability to be minimum 0.05 Perm-inch without any external barrier with protection against harmful Microbes as per ASTM G-21/UL-181/ASTME-2180-18 with Antimicrobial & Antiviral additive to be EPA approved for use in Drain piping. The material should have JIS Z 2801 Standard for Anti Viral Properties. The insulation material shall and have ozone resistance as per ASTM D 1149 . Adhesives to be GRIHA/IGBC compliant. Installation should be as per manufacturers SOP.
TOTAL OF PART IV-A-4 : CHILLED WATER PIPE AND PIPE INSULATION
PART IV-A-5 : CHILLED WATER VALVE ACESSORIES
SITC of BALANCING VALVE WITH BUILT IN MEASURING FACILITY with CI body flanged construction with EPDM coated disc with long pitch with protected out pipe insulation & PN 16 pressure rating for chilled /hot water circulation as specified.
SITC of BUTTERFLY VALVE (MANUAL) with C I body SS Disc, Nitrile Rubber Seal & O-Ring PN 16 pressure rating for chilled water eater circulation as specified (CHW Valves)
Supply, Installation, Testing & Commissioning of Ball Valve with Gun Metal Body & SS Moving Part. It will be applicable for Test point & Drain. The valve shall be insulated as per insulation specification
Supply and Installation of Flexible Groved Couplings for Chilled Water Chiller, Pump & Cooling tower etc. Connection as per the drawing, specification and as per instruction of Engineer-in Charge.
Supply Fixing Testing Commissioning of Following sizes Motorized Butterfly valves with C I body, SS Disc, O - ring and minimum PN- 16 pressure rating, confirming to BS 5155, IS 13095, with IP-55 actuator, capable of accepting up to 10V DC, and Up to 20mA electric Signal and providing similar transduced feedback output to control system as required. Note : It should be on/off type.
SITC of Y - STRAINER of Ductile Cl Body flanged ends with stainless steel strainer for chilled / hot water circulation including insulation as specified Notes : Strainers shall have a removable stainless steel minimum 1mm thick screen with 3 mm perforations. Strainers shall be provided with flanges / threaded sockets as required. Note : It should be with permanent magnet
Supplying, fixing, testing and commissioning of following sizes 2 WAY High Rangeability modulating control valve (Pressure Independent Balancing Control Valve - Energy Valve) with CI Body, Suitable to ensure constant delta T across the AHU coil , SS Disc,O - ring and minimum PN-16 pressure rating , conforming to BS 5155, IS 13095, The actuator shall be capable of accepting upto 10V DC and upto 20mA electric signal and shall provide similar transduced feedback output to control system. It should be BMS compatible. The valve shall be insulated as per insulation specification (Rates Shall be including Insulation). Sizes to be as per approved drawing of the department / Consultants (Valves shall be with Flanged end 125 to 50 mm NB / Threaded 40mm NB and below) Valves to be installed on
SITC of Automatic Air Purge/Release Valve. This arrangement assemble with Ball Valve, 1" Nipple of 150mm length. Valve material should be brass type and suitable upto 10bars operating pressure. The assembly shall be insulated as per insulation specification
Providing and fixing in position the industrial type pressure gauges with gun metal / brass valves complete with 150 mm dial size with SS needle valve and fittings 0-10 kg / cm2 range as required
Providing & fixing in position the mercury in glass industrial type thermometers 0 - 50 °C range.
SITC of insulated Braided Coil Flexible Connector for chilled water FCU. The same will be connected between the last point of MS Chilled water pipe and the FCU connection as per site condition. The scope covers 2 nos of braided connected for each FCU connection
U Tube Hg Manometer Instandered Construction With Required Fixtures And Calibration Chart
Supply, Installing, Testing and commissioning of PN-16 pot strainer, MS (IS 2062-1992 Gr A) body and bonnet with Stainless Steel 3 mm perforated x 24 G thick filter screen, black rubber gasket, heavy duty mild steel hand wheel & stainless steel-410 drain plug etc. Testing confirming to BS - 6755 Part-1. As per specification/drawings and as directed by Engineer In Charge.
350 mm NB - Pot Strainer
Suitable for 100 mm Water supply connection to Cooling Tower
Suitable for 350 mm for CHW Connection
Chemical Flushing of the chilled water pipe network as per the specifications
Providing class 1/2 following diameter Gate Valve (full way) of brass or gun metal with Cast iron wheel conforming to IS:778, fixing to pipe line including the cost of white zinc, spun yarn etc., testing for leak proof joints at a hydraulic pressure of 10 Kg / Sq.cm, rectifying the leakages if any, all complete as per specification and as directed. Note: 1) Wherever required union joint shall be provided in pipe to facilitate removal of valve. 2) Threaded fittings of CPVC/UPVC shall be of Brass Threaded only. PN 1.6 valves
Supplying & fixing following Stainless Steel (grade 316) spool pieces of required diameter having flange on one/ both end with flange holes in flanges for fixing with nut & bolts (OR) with screwed ends on both/ one end as per site requirement and as directed by the Engineer in charge, having 450 mm/ required length, providing 3D x 3D (where D is the outer diameter of pipe) and 4 mm thick stainless steel puddle plate (minimum size 150mmx 150mm) welded to it including cutting the plate to required shape and fixing in the reinforcement at the center of RCC wall/ slab at required level, height etc including cutting the form work provided for casting concrete etc., complete all as per specifications and as directed by Engineer-in-Charge. Note:- Actual weight of spool piece only will be measured for payment and no payment will be made for any wastages.
50 mm dia
65 mm dia
TOTAL OF PART IV-A-5 : CHILLED WATER VALVE ACESSORIES
PART IV-A-6 : AIR DISTRIBUTION SYSTEM
Sheet Metal Work Supply installation balancing & Commissioning of Factory Fabricated GSS sheet metal rectangular / round ducts, complete with neoprene rubber gasket, elbows, splitters dampers, vanes, hangers, supports etc as per approved drawings & specifications of following sheet thickness complete as required. Note : Sheet should be 120 GSM
Thickness 0.63 mm sheet (750 mm & Below)
Thickness 0.8 mm sheet (751 mm to 1500 mm)
Thickness 1.00 mm sheet (1501 mm to 2250 mm)
Sheet Metal Work Supply installation balancing & Commissioning of Fabrication at site GSS sheet metal rectangular / round ducts, complete with neoprene rubber gasket, elbows, splitters dampers, vanes, hangers, supports etc as per approved drawings & specifications of following sheet thickness complete as required. Note : Sheet should be 120 GSM
Thickness 0.63 mm sheet (750 mm & Below)
Thickness 0.8 mm sheet (751 mm to 1500 mm)
Thickness 1.00 mm sheet (1501 mm to 2250 mm)
Supply and installation of MS Welded rectangular ducts, complete with required flanges , necessary supports of pregalvanised steel of 275 GSM and Grade 4.8 strength class threaded rods (as directed) and ETA Approved anchor bolts, supply air collars, vanes, splitters dampers and as per specification for Air Conditioned Areas - For Kitchen Exhaust
16 G MS Ducting
Supply Installation Testing And Commissioning Of Diffusers/ Grilles As Per Following Schedule
Supply & Fixing of Powder coated extruded aluminium Supply Air Grills with aluminium volume control dampers as per specifications.
Supply & Fixing of Powder coated extruded aluminium Return Air Grills without volume control dampers completed as required.
Supply, Fixing, Testing, Commissioning of Supply air diffusers powder coated aluminium volume control dampers with anti smudge ring & removable core.
Supply & Fixing of Powder coated extuded aluminium Displacement ventilated Perforated diffuser suitable for out let air velocity of 0.5 m / sec, the unit will supply with its pleanum box. The supplied plenum box's cross section sizes should be 50mm bigger than the diffuser size and height as per supplier / vendor's design. The plenum should be supplied with inside or outside insulation as specified insulation specification. Diffuser size : (1200 mm X 450 mm)
Supply, Installation, Testing, Commissioning Of GI Powder Coated Duct Dampers
Supply, installation, testing and commissioning of Gl volume control duct damper complete with neoprene rubber gaskets, nuts, bolts, screws linkages, flanges etc, as per specifications.
Supplying, Fixing testing and commissioning of fire dampers in supply air duct/main branch and return air path as and where required of required sizes i/c control wiring, the damper shall be motorized and spring return so as to close the damper in the event of power failure automatically and open the same in case of power being restored. The spring return action shall be inbuilt mechanism and not externally mounted. The damper shall also be closed in the event of fire signal complete as required and as per specifications. Note : Dampers shall be fire & smoke type and BMS compatibility as per specification
Fire Damper
Actuator
Rain Protected Façade Louver Grill
Supply, installation, testing and commissioning of decorative facade louver grill suitable for rain protection. Colour & Finish : Approval shall be obtained from Architect Planner / Interior consultant. As per specification/drawings and as directed by Architect & Engineer In Charge
Flexible Canvass Connections
Supply , installation, testing commissioning of Flexible canvass connections to isolate vibrations produced by Air handling units , fans and other air moving equipments when these are to be connected to air ducts where ever specified. Canvass connections shall be of the same cross-sectional area as the mating fan inlet/outlet or duct section. Flexible Duct connector shall be tested and certified in accordance with BS 476 part 7 for class 1 and NFPA -701 from NABL accredited lab for which test certificated need to be submitted.
VAV Box Supply of Pressure Independent Variable Air Volume boxes (AHRI Certified) with cross flow sensor of amplification factor 2 to 3 for accurate measurement with pressure signals , consisting of BACnet/MSTP communicable DDC controller (Fully controllable BTL certified ), BMS Compatible, damper actuator, low pressure velocity transducer, temperature sensor & digital room thermostat. Minimum flow should be maintained as per OEM standards. VAV should be dynamically calibrated & tested in factory on live test bed as per designed CFM. Each unit shall supplied with LCD Display room thermostatic controller with require length of communicable wire with duly laid in HMS PVC conduit.
VAV-10 - 3700 to 5000 CFM
VAV-12 - 7100 to 11500 CFM
Duct Thermal Insulation Supplying and fixing of following thickness duly laminated aluminium foil of mat finish closed cell nitrile rubber (Class "O") insulation on existing duct after applying suitable adhesive for nitrile rubber. The joints shall be sealed with 50mm wide and 3mm thick self adhesive nitrile rubber tape insulation complete as per specifications and as required.
Nitrile rubber Insulation - 13 mm ( Ducts in the loose return air path )
Nitrile rubber Insulation - 19 mm ( Duct routed in non conditioned spaces )
Nitrile rubber Insulation - 25 mm (Duct Routed in Ambient spaces)
Insulation Protecting Cover (For Duct / CHW / VRF pipe Insulation within the Building)
SITC of self-adhesive fiber glass cloth which is Acrylic based woven fiberglass fabric made from E glass(self adhesive) and has total thickness 0.19±0.02 mm. It shall have GSM 280 (±5%). Material should be Rodent Residence and it shall supply with Colour As per Design - Red / Blue / Green / Black / Gray / other as per requirement.
Insulation Protecting Cover (For Duct / CHW / VRF pipe Insulation Outside the Building & Plant Rm)
Insulation shall be covered with Aluminum Cladding for mechanical protetion. It shall be Aluminum cladding of 26G thickness sheet. Item should be fixed with joints & Rivets. Joints for Elbow & Valve shall be considered.
Duct Acoustic Insulation Providing and fixing acoustic Insulation of open cell nitrile rubber sheet having density of 180-220 kg/m3 and recommended thickness of 15 mm. Absorption coefficient value of Insulation material shall be 0.90 for the 2000 Hz frequency band in accordance to IS:8225/ISO:354/ASTM 423C. Material shall have fire class 1 as per BS 476 , part 7. Material Shall be EPA approved and Anti-Fungal & Anti- Bacterial in accordance with ASTM G21 & ASTM E 2180 respectively. It shall be fixed inside of the duct with the help of adhesive as per the specifications given.FSK tape shall be applied at joints.
15 mm (For AHU Ducts)
10 mm (For CSU & FCU Ducts)
Kitchen Exhaust Duct Insulation (within the building) Supply & Fixing insulation over exhaust duct with fire rated insulation in encapsulated fire wraps having density of 96 kg/m3 & 25 mm thickness applied with the help of mechnical support & GI flat strip above it. Thermal conductivity (k-value) of base material (Ceramic Wool) shall not exceed 0.035 W/mK at 25˚C means temperature as per ASTM C-518.Base material shall be Confirming to ASTM E 84, NFPA 90A, 90B, LIFE SAFETY CODE NFPA101. Base material shall confirm 2 hours fire rating as per Building Insulation requirement in accordance with ASTM E 119.
Kitchen Exhaust Duct Insulation (Exposed to atmosphere) Supply & Fixing insulation over exhaust duct with fire rated insulation in encapsulated fire wraps having density of 96 kg/m3 & 25 mm thickness applied with the help of mechnical support & GI flat strip above it. Above it additional 26 gauge aluminum cladding shall be applied. Thermal conductivity (k-value) of base material (Ceramic Wool) shall not exceed 0.035 W/mK at 25˚C means temperature as per ASTM C-518.Base material shall be Confirming to ASTM E 84, NFPA 90A, 90B, LIFE SAFETY CODE NFPA101. Base material shall confirm 2 hours fire rating as per Building Insulation requirement in accordance with ASTM E 119.
AHU ROOM ACCOUSTIC INSULATION Providing and fixing acoustic Insulation of open cell nitrile rubber sheet having density of 180-220 kg/m3 and recommended thickness of 20 mm. Absorption coefficient value of Insulation material shall be 0.90 for the 2000 Hz frequency band in accordance to IS:8225/ISO:354/ASTM 423C. Material shall have fire class 1 as per BS 476 , part 7. Material Shall be EPA approved and Anti-Fungal & Anti- Bacterial in accordance with ASTM G21 & ASTM E 2180 respectively. It shall be fixed inside of the surface with the help of adhesive as per the specifications given. FSK tape shall be applied at joints.
20 mm thick
Under Deck Insulation
Supply & Fixing Under deck Insulation with 50 mm thick Fire Retardant Extruded Polystyrene having density of 32 Kg / M3 and thermal resistance of 1.78 M2 K / W
TOTAL OF PART IV-A-6 : AIR DISTRIBUTION SYSTEM
PART IV-A-7 : VENTILATION SYSTEM
200 CFM / 25 mm TSP
300 CFM / 25 mm TSP
350 CFM / 30 mm TSP
500 CFM / 25 mm TSP
700 CFM / 25 mm TSP
750 CFM / 30 mm TSP
1000 CFM / 25 mm TSP
1000 CFM / 30 mm TSP
1800 CFM / 30 mm TSP
2200 CFM / 30 mm TSP
2400 CFM / 30 mm TSP
2500 CFM / 40 mm TSP
3000 CFM / 40 mm TSP
4000 CFM / 40 mm TSP
5400 CFM / 40 mm TSP
6500 CFM / 50 mm TSP
6600 CFM / 40 mm TSP
7500 CFM / 40 mm TSP
11000 CFM / 40 mm TSP
15000 CFM / 40 mm TSP
1200 CFM / 25 mm TSP
1300 CFM / 30 mm TSP
1700 CFM / 40 mm TSP
2000 CFM / 40 mm TSP
2500 CFM / 30 mm TSP
3500 CFM / 30 mm TSP
5600 CFM / 40 mm TSP
6400 CFM / 40 mm TSP
9400 CFM / 40 mm TSP
13000 CFM / 40 mm TSP
800 CFM / 25 mm TSP
400 CFM / 25 mm TSP
WALL MOUNTED PROPELLER EXHAUST FAN WITH GRAVITY LOUVERS Supply, Installation, testing & Commissioning of Propeller fan for wall or panel mounting suitable for supply or exhaust use having casing, protection guard and impeller. Impeller shall be made with galvanized steel. Entire assembly shall be black enamel painted to avoid the rust. The fan should have sickle blade impellers with external rotor motor, fan assembly shall be AMCA certified (AMCA certification requird for Air Performance & Sound) & totally enclosed, fan-cooled, provided with class F insulation, and of approved make., Fan shall be provided with TEFC Sq.cage, direct driven B' Class induction motor with minimum IP-54 protection Motor shall be suitable for 230 ± 5% volts, Single phase, 50 cycles electric supply- I. The motor (Eff1 Class-Motor) Max. noise level shall be 60 dBA at 3 meter The complete fan assembly shall be CE/AMCA/ISO Certified. (Vendor shall submit the certifications for below listed fans)
250 CFM / 15 TSP
300 CFM / 15 TSP
500 CFM / 15 TSP
600 CFM / 15 TSP
1000 CFM / 15 TSP
1500 CFM / 15 TSP
2500 CFM / 15 TSP
KITCHEN EXHAUST FAN a). Supply, Installation, testing & Commissioning of Fan - SISW backward curved centrifugal fan with necessory supports arrangement, sq cage induction motor, GSS frame support work, belt drive with required size pullys and belts, spring type vibratioin isolator, base frame along complete installation include Lifting, shifting, assemblling & positioning of the equipment comprising of the following and complete as per specification/drawings and as directed by Engineer In Charge
d). Fan Static Indicated below are tentative , Contractor shall submit Fan static calculations based on approved shop drawings before ordering the unit. Any rise in static required shall be offer by contractor without any additional cost. Necessary VFD starter with remote operting push button at Kitchen location and power and control cabling from fan to kitchen shall be in scope of HVAC Contract. Power cable will be availabe up to starter panel by electrical contractor.
13015 CFM / 65 ESP
Dry Scrubber
b). Operating voltage - 220 Vac+/-10%, 50 Hz (Single phase) Cell - Ionizing voltage - 12 KVdc Collector voltage - 6 KVdc One cell comprising of 9 ionizing wires and 25 collection plates Controls - Auto cut-off when door is opened. Indicator lights for fault, normal or wash function. Pre-filter - Aluminium mesh, washable Dry contact for BMS. Unit must be of Autowash type.
13015 CFM / 65 ESP
Air Washer Unit Supplying, installing, testing and commissioning of Double Skinned Sandwiched insulated sectionalised construction air washer unit complete with Cellulose Fill Air Washer, giving 90% efficiency at 500 FPM air velocity across pads, factory assembled and complete with 16 gauge GI casing, 3 mm thick SS water tank,plug fans , Cellulose fill, water distribution header, heavy class C PCV piping, brass ball valves , make up connection with float valve, drain connection with drain valve, for quick fill with valves, overflow connection, isolation of tank, pumps and brass strainers, Y strainers and necessary fittings. The quoted price shall also include provision of GSS partitions duly reinforced at intake side of air washer and GSS louvers with bird-screen fabric filters and drift eliminators. The price shall also include horizontal monoblock pumps of Beacon weir / KEC make of suitable rating (including one standby pump), factory mounted on mild steel channel base with electric motor for circulation of water. Pumps shall be aligned and suitable for 415±6% volts, 50 cycles 3 phase power supply. One No. 3 phase isolator switch in weather proof enclosure shall be provided near motor.
starter with remote operting push button at Kitchen location and power and control cabling from fan to kitchen shall be in scope of HVAC Contract. Power cable will be availabe up to starter panel by electrical contractor.
7770 CFM / 65 ESP
Air Curtaion Unit Supply, Installation, Testing and commissioning of Air Curtain as per specifciation.
1800mm ( Length )
900mm ( Length )
STP Exhaust Air Foul Odor, Microorganisms & Pollutant Destruction System
STP Exhaust Air Foul Odor, Microorganisms & Pollutant Destruction System
TOTAL OF PART IV-A-7 : VENTILATION SYSTEM
PART IV-A-8 : VRF SYSTEM
VRF AHU a) Supply, Installation, testing & Commissioning of Factory built Outdoor mounted VRF System Connected AHU as per the Specification and AHU Schedule with thermal break profile having internally lined acoustic panels and complete with Plug Fan. Unit Shall in double skin construction, comprising of supply air section, fresh air section, filter section , limit switch, drain connections, purge section & Inspection light. SA / RA / FA Al. aerofoil dampers, stainless steel (18G) drain pan with Nitrile rubber insulation 19 mm thick, auto purge valve, drain valve as required for complete installation include SITC , Lifting, shifting, assemblling & positioning of the equipment comprising of the following and complete as per specification/drawings and as directed by Engineer In Charge. b). Unit must in Double skin type with Extruded Aluminium profile having thermal break , internaly acoustic lined and complete with Plug fan, min 48±2 mm thick panels consisting of GI casing of thickness 0.8mm pre-plasticized outside & 0.8 mm non coated inside layer with factory injected PUF (Density-40±2 kg/m3) between them.
f). Minimum 6 row deep cooling coil.Coil face velocity shall be kept 500 FPM, Coil shall have hydrophilic coating & SS End Plates: - Material of Tube - Copper g). Fan Static Indicated below are tentative , Contractor shall submit Fan static calculations based on approved shop drawings before ordering the unit. Any rise in static required shall be offer by contractor without any additional cost.
10000 CFM , ESP -35 mm , 20.0 TR AHU (N1-RF-FMAHU-01 / 02)
VRF TREATED FRESH AIR UNIT a) Supply, Installation, testing & Commissioning of Factory built Outdoor mounted VRF System Connected AHU as per the Specification and AHU Schedule with thermal break profile having internally lined acoustic panels and complete with DIDW Direct Drive Fan. Unit Shall in double skin construction, comprising of supply air section, fresh air section, filter section , limit switch, drain connections, purge section & Inspection light. SA / RA / FA Al. aerofoil dampers, stainless steel (18G) drain pan with Nitrile rubber insulation 19 mm thick, auto purge valve, drain valve as required for complete installation include SITC , Lifting, shifting, assemblling & positioning of the equipment comprising of the following and complete as per specification/drawings and as directed by Engineer In Charge. b). Unit must in Double skin type with Extruded Aluminium profile having thermal break , internaly acoustic lined and complete with DIDW direct driven fan, min 48±2 mm thick panels consisting of GI casing of thickness 0.8mm pre-plasticized outside & 0.8 mm non coated inside layer with factory injected PUF (Density-40±2 kg/m3) between them.
e). Filter sections with velocity less than equal to 500 FPM. - MERV 8 (confirming to standard ASHRAE 52.2) f). Minimum 8 row deep cooling coil.Coil face velocity shall be kept 500 FPM, Coil shall have hydrophilic coating & SS End Plates: - Material of Tube - Copper g). Fan Static Indicated below are tentative , Contractor shall submit Fan static calculations based on approved shop drawings before ordering the unit. Any rise in static required shall be offer by contractor without any additional cost.
600 CFM , ESP -15 mm , 8 Row Coil, 3.0 TR Treated Fresh Air Unit (N1-RF-TFAU-01)
900 CFM , ESP -15 mm , 8 Row Coil, 4.5 TR Treated Fresh Air Unit (N1-RF-TFAU-03)
1100 CFM , ESP -15 mm , 8 Row Coil, 5.5 TR Treated Fresh Air Unit (N1-RF-TFAU-02)
VRF Coil Kit for 20 TR Unit ( VRF ODU - 24 HP )
VRF Coil Kit for 3 TR Unit ( VRF ODU - 4 HP )
VRF Coil Kit for 4.5 TR Unit ( VRF ODU - 6 HP )
VRF Coil Kit for 5.5 TR Unit ( VRF ODU - 8 HP )
Ductable Type AC Unit Supply, installation, testing and commissioning of following minimum capacity and external static pressure VRF/VRV ceiling mounted ductable type Indoor unit equipped with washable synthetic media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX copper coil, electronic expansion valve, corded remote control, outer cabinet, vibration isolators, drain pan, other necessary supports etc., suitable for operation on single phase AC supply 230 V ± 10%, 50 Hz complete as required. The unit shall have automatic force shut down provision in case of fire on receiveing signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature
Mid Static Ductable units (minimum 45 pascal external static pressure) 4.0 TR Mid static Ductable Unit
High Static Ductable units (minimum 110 pascal external static pressure) 5.5 TR High static Ductable Unit
8.0 TR High static Ductable Unit
Hi wall Type AC Unit Supply, installation, testing and commissioning of following minimum capacity VRV/VRF High wall type Indoor unit equipped with washable synthetic media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX copper coil, electronic expansion valve, outer cabinet, cord less remote control, drain pan, necessary accessories etc., suitable for operation on 230 V ± 10%, 50 Hz, single phase AC supply, complete as required. The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS System.
2.0 TR Hi wall Type AC Unit
One Way Cassette Type AC Unit Supply, installation, testing and commissioning of following minimum capacity 1-way flow VRV/VRF Cassette Type Indoor ceiling mounted unit equipped with synthetic washable media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX Copper coil, electronic expansion valve, outer cabinet, drain pump, grill, necessary supports, vibration isolation, cord less remote control etc., suitable for operation on single phase 230 V ± 10%, 50Hz AC supply, complete, as required. The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS System.
1.0 TR One Way Cassette Type AC Unit
1.5 TR One Way Cassette Type AC Unit
VRF Out Door Unit Supply Installation, Testing & Commissioning of modular type Variable Refrigerant Volume air cooled Outdoor units suitable for cooling only, having all hermetically sealed inverter type Scroll Compressor(s), microprocessor based Controller, top discharge type condensing unit(s), with R410 A Refrigerant (Or Eco Friendly Green Gas if any), vibration isolators, with suitable foundation, MS Stand for Unit with necessary paint etc. complete as required. The unit shall deliver the rated capacity at AHRI Conditions and work even at 50°C ambient temperature without tripping. The unit shall be suitable to work on 400V +/- 10%, 3 Phase, 50Hz AC power supply. The unit shall be filled with first charge of the refrigerant and ready for use as required. The COP at AHRI conditions shall not be less than 3.1 and IEER not less than 6.5. (Design should be got approval before execution from engineer in charge)
VRF System Remote Controller
Supply / Installation / Testing and Commissioning of Corded remotes with LCD Desplay for VRF indoor units ( All IDUs except High Wall Units )
Supply / Installation / Testing and Commissioning of Cordlesss remotes for VRF indoor units ( For Hi Wall Type IDUs )
Supply, Installation, testing & Commissioning of Central Controller for entire VRV system , the scope includes the control wiring and conduting of the same in a lot. Controller should capable for 30nos +20% IDU&ODU. The controller shall be progremmed for soft integration with the building BMS system. The controller have LCD screen and touch panel for onplace controlling.
Branch Distrubution refrigerant Pipe joints with precase insulation
Supply of Branch Distribution Joints for VRF system.
Refrigeration Piping & First Charge of Refrigerant For VRF System Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft / hard drawn copper refrigerant piping for VRV / VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing / brazing including accessories, insulated with Class O tubular insulation closed cell elastometric nitrile rubber having factory bonded GC bonding of specified thickness as given below for Suction and Liquidlines, all accessories as per specifications etc. as required. All the exposed pipe insulation have an additional protective cover of UV resistant paint suitably covered with glass cloth as per specification :
9.5 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation
12.7 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation
15.86 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation
19 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm with 19 mm thick insulation
22.2 mm dia (OD) (Hard drawn) with tube thickness 1.62 mm with 19 mm thick insulation
28.58 mm dia (OD) (Hard drawn) with tube thickness 1.62 mm with 19 mm thick insulation
34.9 mm dia (OD) (Hard drawn) with tube thickness 1.62 mm with 19 mm thick insulation
41.27 mm dia (OD) (Hard drawn) with tube thickness 1.62 mm with 19 mm thick insulation NOTE:- 1)The Copper Piping & Piping Circuit should be with Minimum Number of joints, which shall be attained by : (1) Using One End Expanded Tubes (2) Bending the tubes instead of using elbow joints wherever 90 degree bending is required. (3) Piping should be routed at site in such a manner, that brazed joints in the refrigeration piping are kept to a minimum. (4) The makes of tube fittings shall be same as that of tubes. (5) The thickness of fittings used shall be same as that of the pipe.
4 HP Capacity
6 HP Capacity
8 HP Capacity
24 HP Capacity
26 HP Capacity
Power & Communication Cabling For VRF System
Tray with cover For VRF pipings
Supply and Installation of GI perforated trays with Top close cover for VRV / VRF system refrigerent piping for outdoor areas. Piping tray and top cover should be 18G thickness and with complete fittings & supports, with 450mm width or suitable size, jointing accessories, and all installation accessories as required.
TOTAL OF PART IV-A-8 : VRF SYSTEM
PART IV-A-9 : CIVIL SUPPORT STRUCTURE
Civil Support Structure
Vibration Absorbent spring supports for AHUs / Fan Units ( 4 to 8 Support for each )
Engineered Rubber Support Pad for Split AC Out Foor Unit (Set considered for All Legs).
MS Welded Structure (Supply and erection of M.S. angle stand with 1 cot of red oxide Primer then synthetic epoxy paint )
Core Cut up to 150mm Dia
Ceiling of All AHU Room The pipes & duct works includes making holes/cutout in brick or RCC walls, slabs/ roofs and making good the damages by bringing to the original condition to the satisfaction of the Architect/Consultant/Client. With sound absorbing and fire retardant ceiling material ensuring water tight joints.
VRF ODU Engineered floor support ( 4 to 6 Support for each ODU ) Support shall have heavy duty framework, non drill system shall have anti-vibration pads. Material of frameworks shall be galvanising to BS EN ISO 1461:1999.
Vibration Absorbant spring supports for Chiller ( 4 to 8 Support for each Chiller )
Vibration Absorbant spring supports for Pumps ( 4 to 8 Support for each )
TOTAL OF PART IV-A-9 : CIVIL SUPPORT STRUCTURE
TOTAL OF PART IV-A ( HVAC System)
PART IV-B : HVAC BUILDING MANAGEMENT SYSTEM
PART IV-B-1 : BMS SERVER / WORK STATION COMPUTER / PRINTER
Design, Supply, Installation, Testing and Commisioning (DSITC) of the Server cum Workstation as follows: Processor Intel Xeon 2.8 GHz, Quad core CPU. RAM 16 GB or Higher Key Board & Mouse: 12 function-key keyboards (English) with Mouse pointing device. (Raid 5 Configuration) DVD +/- RW Drive Required USB PORT Required Ethernet Ports Required OS : 2019 or 2022 Server License Trend analysis, graph, and report generation : Required
Design, Factory Testing where applicable, Supply, Installation and commissioning of Building Automation System Client Grade Work station with i7 Based with 8 GB RAM Graphics Card – Two NVS 315 or higher version,1024MB DDR3 or better, NIC (network interface card) for Ethernet Networking compatible with TCP/IP network protocols Complete with with AntiVirus, Client Software compatible with offered BMS SoftwareTotal of HVAC System
SITC of 21" HD flat screen, Color Monitor, minimum 1920 x 1080 resolution, LED display with HDMI, complete with wall mounted/table mounted brackets
SITC of Laser Jet B/W Printer - A4 Size
TOTAL OF PART IV-B-1 : BMS SERVER / WORK STATION COMPUTER / PRINTER
PART IV-B-2 : BMS SOFTWARES / ENERGY MANAGEMENT
Supply, installation, testing & commissioning of the following Software for BMS:
SOFTWARE BMS Software: Niagara Platoform Supported Web Based Graphical Software up to 30000 Tag Point Based with Unlimited Client User with meeting the requirements in the Given I/O Summary and technical specifications including configuration and facility to create / provide the graphic mapping for all I/O Summary points , animate the Graphics, Navigation between pages, display of logs, changing the time zones, popup alarms, configurable password protection for Building Management System as per Specifications. The BMS GUI software should be with email Facility supporting not less 10,000 points. This data shall reside on a server for all database access. Systems requiring proprietary database and user interface programs shall not be acceptable. Software shall be able to communicate with Lonworks, BACnet, Modbus devices simultaneously, with unlimited user capacity. (All required Software with original license competent with BMS software)
Supply, Installation, Configuration, Programming, of Web Based Energy Management for 250 Nos. of Energy Meters, & Reporting Tool software for Monitoring Building efficiency & Customization of Energy Management Application that will Communicate with the Main Framework having Capability of Energy Profiling, Energy Mapping, Load Calculations, Predictive Energy Analysis, Energy Spectrum Analysis etc as per Functional Specifications of the Bid for 250 points. Bidders Must Consider all Application Modules and Licenses to be Part of the Bid.
Web based RUNTIME Unlimited Client User Software for "View & Operation" Application
Supply of Licensed version, Installation, Testing, Progrmming, Configuration, Data base generation, Integration, Commissioning of Email / SMS Notification module which shall function as any Alarm Log being transmitted as email and as SMS Text message; the receipients shall be decided by the owner at the time of software development stage post order but shall be minimum configured for 5 receipients for Email and SMS text Note : The BMS Software,Controllers,Field divices/Sensors & Protocol Integrators should be UL & BTL Approved & Certified
TOTAL OF PART IV-B-2 : BMS SOFTWARES / ENERGY MANAGEMENT
PART IV-B-3 : IP BASED 3rd PARTY INTEGRATOR
Supply, Installation, Testing, Commissioning of INTEGRATION OF FOLLOWING SYSTEMS ON MODBUS-rtu / BACNET: The corresponding mentioned third party vendor shall be responsible to provide serial converter [RS 485 to RS 232] and the BMS vendor to accommodate the software address required for integration. including all necessary mounting hardware and accessories. All Integrators are Must be with Dual IP Port with 32 Bit Microprocessor Based, with inbuilt RTC, Integrator Should be Same OEM Manufacturing, 3rd Party Make Integrator Strictly not Allowed, Each Integrators should be UL & BTL Approved & Certified.
Developing and commissioning of software interface for CPM Soft Data Integration on Modbus-RS485 / Bacnet Over IP as per IO Sumamry.
Developing and commissioning of software interface for FIRE ALARM SYSTEM Soft Data Integration on Bacnet Over IP as per IO Sumamry. (Upto 500 Soft point)
Developing and commissioning of software interface for VFD, IAQ, VAV BOXES Soft Data Integration on Modbus-RS485 / Bacnet Over IP as per IO Sumamry.
Developing and commissioning of software interface for THERMOSTATE Soft Data Integration on Modbus-RS485 / Bacnet Over IP as per IO Sumamry. (For 1 FCU)
Developing and commissioning of software interface for THERMOSTATE Soft Data Integration on Modbus-RS485 / Bacnet Over IP as per IO Sumamry. (For 2 FCU)
Developing and commissioning of software interface for THERMOSTATE Soft Data Integration on Modbus-RS485 / Bacnet Over IP as per IO Sumamry. (For 3 FCU)
Developing and commissioning of software interface for THERMOSTATE Soft Data Integration on Modbus-RS485 / Bacnet Over IP as per IO Sumamry. (For 4 FCU)
Developing and commissioning of software interface for THERMOSTATE Soft Data Integration on Modbus-RS485 / Bacnet Over IP as per IO Sumamry. (For 5 FCU)
TOTAL OF PART IV-B-3 : IP BASED 3rd PARTY INTEGRATOR
PART IV-B-4 : DDC CONTROLLERS
IP BASED DDC CONTROLLERS: SITC of Supply Installation, Testing & Commissioning of Onboard Dual IP Port with 32 Bit Microprocessor Based Direct Digital controllers with IO Module Expandable, Each DDC Shall Support up to 145 Input / Output, Master Slave Topology is NOT acceptable, it shall be supporting BACNet / Modbus communication platform designed for the required IO paramteres as per Mentioned In IO Summary with 20% Spare IO. Use of AI to DI multiplexer is also not acceptable. Each Controllers should be UL & BTL Approved & Certified.
IP DDC FOR HVAC CHW BASED FLOOR MOUNTED AHU ALONG WITH EXHAUST FANS AS PER IO SUMMARY (1 AHU + 1 EX.FAN PER DDC)
IP DDC FOR HVAC CHW BASED FLOOR MOUNTED AHU AS PER IO SUMMARY (1 AHU with 2 nos. fans PER DDC)
IP DDC FOR HVAC CHW BASED FLOOR MOUNTED AHU AS PER IO SUMMARY (1 AHU with 1 no. fan PER DDC)
IP DDC FOR HVAC CHW BASED CS AHU AS PER IO SUMMARY (1 CSU PER DDC)
IP DDC FOR HVAC CHW BASED CS AHU AS PER IO SUMMARY (2 CSU PER DDC)
IP DDC FOR HVAC CHW BASED TFA AS PER IO SUMMARY (1 TFA PER DDC)
IP DDC FOR HVAC CHW BASED HRU AS PER IO SUMMARY (1 TFA with HRU PER DDC)
IP DDC FOR HVAC VENTILLATION FANS (EXHAUST / TOILET FANS / PROPELLER FANS) AS PER IO SUMMARY
ENCLOSURE / PANEL SITC of Supply Installation, Testing & Commissioning of Rittal / Hoffmann Make Enclosure Panel Also with lockable MS mounting with ELMAX Make connectors, strip current transformer, MCB, internal wiring & relays,shall confirm its I/O provision w.r.t requirement on basis of data point).
Supply, installation, testing and commissioning of hand held Touch portable operator terminals. (POT). These shall be required if the Controllers and Integration Units do not have a built in keypad on the facia . With required connectors etc. - 7inch
TOTAL OF PART IV-B-4 : DDC CONTROLLERS
PART IV-B-5 : SENSORS & FIELD DEVICES
Supply, Installation, Testing & Commissioning (SITC) of Water Level Transmitter as per technical specification.The rate shall be inclusive of all necessary fittings & Accessories to install the same .
Supply, Installation, Testing & Commissioning of Outside Air Ambient Temperature & RH Sensor as per technical specification. The rate shall be inclusive of all necessary fittings & Accessories to install the same . Temp - 0 to 100 Deg C, RH 0 - 100%. Accuracy 2%.
Supply, Installation, Testing & Commissioning of Air Type Differential Pressure switches the for indicating the Blower status in Air able to measure pressure at zero pascal pressure..(DP Range : 40 to 400 Pa) with two plastic tubes, outside diameter: 6.0 mm (0.24”) & IP 54 Protection.
Supply, Installation, Testing & Commissioning of Duct Mount Temperature with Humidity Transmitter (Temperature Range : 0 to +40 °C, Accuracy : :± 0.5 °C) & (Humidity Range :0 to 100 %RH non-condensing, Accuracy : :± 3 %RH)
Supply, Installation, Testing & Commissioning of Air Type Differential Pressure switches the for indicating the Filter status in Air able to measure pressure at zero pascal pressure..(DP Range : 40 to 400 Pa) with two plastic tubes, outside diameter: 6.0 mm (0.24”) & IP 54 Protection.
Supply, Installation, Testing & Commissioning of Duct CO2 Sensor as per technical specification. The rate shall be inclusive of all necessary fittings & Accessories to install the same . 0 - 2000 PPM. Accuracy - 2%
Supply, Installation, Testing & Commissioning of Duct DEW point Sensor as per technical specification. The rate shall be inclusive of all necessary fittings & accessories to install the same. -40 to +60 Deg CDP. Accuracy - 2%
Supply, Installation, Testing & Commissioning of IAQ (Internal) Sensor as per technical specification. The rate shall be inclusive of all necessary fittings & Accessories to install the same . Range 0 - 2000 PPM, Accuracy - 2%
Supply, Installation, Testing & Commissioning of Relay for High Voltage to Potential Free Conversion with all Accessories.
TOTAL OF PART IV-B-5 : SENSORS & FIELD DEVICES
PART IV-B-6 : NETWORK SWITCH
Supply, Installation, Testing & Commissioning of 24 Port L3 Switches with 10% spare ports as specified Minimum Feature : IP v4: Static Routing, OSPF, RIP, VRRP, ECMP, PIM Spares Mode, SSM IP v6: Static Routing, RIPng, OSPFv3 IP v6 Tunneling Router Discovery Protocol
Supply, Installation, Testing & Commissioning of 24 Port L2 Switches - Type Network Switch with 10% spare ports as specified Minimum Feature : MAC based Learning IEEE 802.1QVLAN Supportforatleast1200VLANs. 802.1s and802.1w IPv4: IGMPv1, v2and v3 IPv6: MLD Multicast VLAN Registration Link Aggregation based on 802.3adacrosstheswitches.
Rack Side Data Accessories
Supply, Installation, Testing & Commissioning of Cat 6 24 port loaded rack mountable Patch panel, fully unshielded
Supply, Installation and dressing of 6U wall mount rack with single position fan tray, front door, cable mangers, 4 socket power strip and mounting hardware.
Supply, Installation, Testing & Commissioning of 2 Mtr Cat 6 patch cord with 24 AWG suitable for GIGAbit connection, it should be suitable to maintain the bending radius as per relevant code, tender specification and direction of engineer in charge for data
Supply, Installation, Testing And Commissioning of Single mode Gigabit 1310nm Mini-GBIC module supports up to 10km
Supply, Installation, Testing & Commissioning of 12 Port Light interface Unit (LIU) with splicing & required accessories
Supply, Installation, Testing & Commissioning 24 Port Light interface Unit (LIU) with splicing & required accessories
Supply installation testing commissioning of CAT6 IO
Supply installation testing commissioning of CAT6 Patch cord
Supply, Installation, Testing & Commissioning of Optical Fibre patch cord LC SC 3 RMT
Supply, Installation, Testing & Commissioning of Optical Fibre patch cord LC LC 3 RMT
Supply, Installation, Testing & Commissioning of Optical fibre pigtail single mode
SITC of Accessories viz Face Plate / Back Box etc
SITC of Loaded LIU Rack mount BLK with Splice Tray and Cable spool 6 Port each
Supply, Installation, Testing And Commissioning of O. F. Cable 6F Loose Tube Single Mode.
SITC of Fibre Splicing on Site
TOTAL OF PART IV-B-6 : NETWORK SWITCH
PART IV-B-7 : CABLES & ACCESSORIES FOR BMS
Supplying, installing, testing and commissioning (SITC) of 2 Core X 1.0 Sqmm Shielded Armoured FRLS Copper Cable Specification : 500 Voltage Grade, Cable type pair, Conductor ABC, Conductor Class II, Insulation XLPE, Overall Shielding, Inner Sheath Type ST2 extruded, Armouring Galvanized Steel Wire, Outer Sheath ST2 FRLS Blue as per IS 5831-1984
Supplying, installing, testing and commissioning of 4 Core X 1.0 Sqmm UnShielded Armoured FRLS Copper Cable Specification : 500 Voltage Grade, Cable type pair, Conductor ABC, Conductor Class II, Insulation XLPE, OS-NA, Inner Sheath Type ST2 extruded, Armouring Galvanized Steel Wire, Outer Sheath ST2 FRLS Blue as per IS 5831-1984
Supplying, installing, testing and commissioning of 4 Core X 1.0 Sqmm Shielded Armoured FRLS Copper Cable Specification : 500 Voltage Grade, Cable type pair, Conductor ABC, Conductor Class II, Insulation XLPE, Overall Shielding, Inner Sheath Type ST2 extruded, Armouring Galvanized Steel Wire, Outer Sheath ST2 FRLS Blue as per IS 5831-1984
Supplying, installing, testing and commissioning of 3 Core X 1.5 Sqmm Shielded Armoured Cable Specification : 1100 Voltage Grade, Cable type Multicore, Conductor ABC, Conductor Class II, Insulation XLPE, Inner Sheath Type ST2 extruded, Armouring Galvanized Steel Wire, Outer Sheath ST2 FRLS Black as per IS 5831-1984 (per DDC to UPS Power Supply).
Supplying, installing, testing and commissioning of CAT-6 Armoured Cable Specification : CAT6, Solid bare copper, Twisted pair, unshielded, Armoured-ECCS Tape, UV & Rodent Protection
Supply and Installation of the following Cable Trays /Accessories Prefabricated hot dip galvanized sheet perforated cable tray including all necessary curved bends-tees reducers,coupler plates, fasteners etc.,for the following sizes. Inclusive necessary fixing arrangement etc.
Cable Tray Size : 50 x 50 x 1.6
Cable Tray Size : 150 x 50 x 2.00
Cable Tray Size : 300 x 50 x 2.00
Supply , Fabrication and Installation of structral steel support like MS plate, angles, channels, etc for Cable tray support , DDC Panel Frame etc. Rate shall inclusive of cutting, welding, grinding, fixing accessories and one coat of primer & two coats of enamel paints, etc. as required.
TOTAL OF PART IV-B-7 : CABLES & ACCESSORIES FOR BMS
TOTAL OF PART IV-B (HVAC BMS System)
PART IV-C : FIREFIGHTING SYSTEM
PART IV-C-1 : FIRE EXTINGUISHERS AND SIGNAGES
Proividing & fixing of Dry Chemical Powder (ABC) type fire extinguisher of 06 Kg capacity either portable or trolley mounted as per approved make fitted with pressure indicating gauge, internal tube, squeeze lever type valve fully charged with ABC powder (Mono Ammonium Phosphate) pressured by Nitrogen complete in all respects including wall suspension bracket and conforming to IS 15683-2006 or latest applicable Indian Standard. The Fire extinguisher shall be supplied and placed without any damage, scratches and loss of accessories as per specifications and as instructed by Engineer-In-Charge.
Providing & fixing of, CO2 type fire extinguisher of 4.5 Kg capacity either portable or trolley mounted, highly effective against B & C class of fire, having ISI certification mark, having flat base including valve, discharge hose & complete in all respects including initial fill with CO2 gas conforming to IS 15683:2006/ IS 2878 or latest applicable Indian standards, wall suspension bracket as required & as per instructions of Engineer In Charge. The Fire extinguisher shall be supplied and placed without any damage, scratches and loss of accessories as per specifications and as instructed by Engineer-In-Charge.
Supplying, installation testing and commissioning of CLEAN AGENT FK 5-1-12 Automatic Modular(Self Activated) fire extinguisher Automatic type 15 kg Fire Extinguishers Applicable fire classes A,B & C, UGTS Pressure Gauge, Empty Weight 6.40 kg, Full weight 21.40 kg. Can Height 425mm, Diameter 400 ± 10mm, Made up from 2 mm thick sheet,, Body Construction Deep Drawn with MIG Welding technology, Brass forged sprinkler valves with Nozzle is specially designed to give more than 99% discharge. Together with orifice characteristic to cover adequately fire risks with scattering cone of 40 to 45° Angle. Internal & External Pure polyester (UV Resistant) powder coated, Heat Sensitive Glass bulb of 68 °C. including pressure indicating gauge , celling mounted bracket.
Providing and fixing of 6 liter K type Fire Extinguisher. In Stainless Steel Cylinders ISI marked fitted with pressure indicating gauge, internal tube, squeeze lever type brass valve fully charged with wet type chemical complete in all respects including wall suspension bracket.
Design, supply and installation of safety signages made of zinc base glow in the dark rigid sheet with high luminous with pasted on 3mm thick on rigid PVC foam sheet. Providing AUTOGLOW Signages in Block / Small Letters of Specified Sizes: Fire Hydrant: 4" X 12"
Design, supply and installation of safety signages made of zinc base glow in the dark rigid sheet with high luminous with pasted on 3mm thick on rigid PVC foam sheet. Providing AUTOGLOW Signages in Block / Small Letters of Specified Sizes: "ABC" Extinguisher: 8" X 4"
Design, supply and installation of safety signages made of zinc base glow in the dark rigid sheet with high luminous with pasted on 3mm thick on rigid PVC foam sheet. Providing AUTOGLOW Signages in Block / Small Letters of Specified Sizes: "CO2" Extinguisher: 8" x 4"
Design, supply and installation of safety signages made of zinc base glow in the dark rigid sheet with high luminous with pasted on 3mm thick on rigid PVC foam sheet. Providing AUTOGLOW Signages in Block / Small Letters of Specified Sizes: "K" Extinguisher: 8" x 4"
TOTAL OF PART IV-C-1 : FIRE EXTINGUISHERS AND SIGNAGES
PART IV-C-2 : FIRE RISER & PIPING SYSTEM
Supplying, installation, testing and commissioning of ‘C' class GI pipe as per IS: 1239 with welded / flanged / screwed joints and also include Design, Fabrication, Supply, installation, testing & commissioning of all the engineered support as per detail technical specification,supports, guides, anchors, etc. including all fresh plate, channel, angles, beams, hardwares, etc,. Complete , heavy clamps, hangers, brackets or pipe supports (all with screwed/welded joints) as required including GI C class pipe of shorter lengths, tapering connecting pieces, short or long bends, GI C class specials like sockets, union nuts, elbows, reducers, plugs, Tees etc. complete to make the system operative as required by LFA/ authorities. all pipe fittings should match with class of pipes. The pipes will have to be laid and fixed on walls, ceilings, into brick walls or RCC with lead anchor fasteners. The work includes making holes in brick or RCC walls, slabs/ roofs and making good the damages by bringing to the original condition to the satisfaction of the Engineer in charge and painting two coats of approved shade(Post office red)of enamel paint over a coat of approved primer for over ground / overheads pipes Note : The piping installation has to be put to hydraulic test to1.5 times the working pressure for 2 hours & as per latest applicable code & standard before applying paint etc. complete
150 mm dia. Pipe
100 mm dia. Pipe
80 mm dia. Pipe
65 mm dia. Pipe
50 mm dia. Pipe
40 mm dia. Pipe
32 mm dia. Pipe
25 mm dia. Pipe
Sypply , installation, testing & commisioning of double flanged CI/Cast Steel sluice valve of rating PN 1.6 with non rising spindle , bronze/gun metal seat, ISI marked complete with nuts , bolts, washers, guslets and conforming to IS 780 or 14846 of following sizes as required:
300 mm dia.
250 mm dia.
200 mm dia.
150 mm dia.
100 mm dia.
80 mm dia.
65 mm dia.
50 mm dia.
40 mm dia.
Supply, installation, testing and commissioning of ball valve ,PN 16.0 tested to 1.5 times working pressure with necessary companion flanges, bolts, nuts, gasket packing, support and any other spares, including indicator for open and shut position as per fire practice etc. complete. 25 mm dia.
Supply, installation, testing & commissioning of Double outlet SS hydrant landing valve conforming to IS 5290 having 80 mm diameter flanged inlet 63 mm diameter instantaneous type female outlet with SS hand wheel, SS blank cap & GI chain conforming to IS 901, twist release type plug including nuts, bolts, washers, gaskets with necessary fittings like Tees, elbows etc. including providing 80 mm diameter GI pipe heavy class conforming to IS 1239 of suitable length to extend the hydrant from downcomer/wet riser making flanged/welded joints, testing the unit, all as per specification and as instructed by Engineer-In-Charge. The GI pipe will be measured separately as per relevant work order item.
Supply, installation, testing & commisioning of single outlet Hydrant valve of oblique Morris pattern Stainless Steel (SS-304) landing valve with C.I./ S.S. hand wheel, detachable stainless steel female coupling, confirming to IS-5290/5041 having instantaneous coupling having 63 mm dia. SS blank cap and chain to suit the hose pipes, including nuts, bolts, washers, gaskets, with necessary fittings like tee, bend etc, testing the unit, all as per specifications and as directed by E-I-C.
Supply and installation of 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) fitted with male and female SS coupling with guaranteed bursting pressure of 35 kg/sq.cm and complete as per the technical specifications and as instructed by Engineer-In-Charge.
Providing and fixing as per ISO fire hose cabinet size 600x 750x 250mm to house fire hydrant and hose, including all other related accessories fabricated from M.S. sheet (16 Gauge) of fully welded construction having front door with locking arrangement, partially glazed with 4 mm thick glass. Cabinet shall be powder coated and painted with post office red colour of size as shown in the drawing (or as approved by EIC) to house the hydrant valve, 15m x 2 No. hose and hose reel.
Providing and fixing approved fire hose cabinet stand mount type for external size 600x 750x 250mm to house fire hydrant and hose, including all other related accessories fabricated from M.S. sheet (14 Gauge) of fully welded construction having front door with locking arrangement, partially glazed with 4 mm thick glass. scope shall also include suitable size MS angle stand and required civil work as per drawing and Cabinet shall be powder coated and painted with post office red colour of size as mentioned in drawing (or as approved by the EIC) to house 15m x 2 No. hoses.
Supplying and fixing Wall Mounted first aid fixed type fire hose reel of braided rubber suitably reinforced 25 mm size and 36 m standard length with 5 mm tapering branch nozzle ,32mm dia. Pipe to connect to riser with cut off ball valve attachment. Hose to be fixed type wall mounted drum and recessing into hose cabinet to suit location including fixing with lead anchor fasteners and bolts ( Including drum and fixing type arrangement ) etc. complete.
Design, supply and fixing of stainless steel (304) orifice plate of not less than 6 mm thick having suitable bore for reducing the pressure at the fire hydrant outlet as per fire brigade requirement and to restrict the operating pressure within 3.5 kg/sq.cm. at the fire hydrant outlet. The orifice plate shall be fixed in position & it shall be fitted between the flanges. The orifice plates shall have test certificate and calibrated to give the required pressure, complete all as per specification, drawings & as directed by E.I.C.
Providing, fixing and testing of forged brass 25 mm dia screwed inlet single acting air release valve PN 16 with 25 mm dia ball valve on inlet side and pressure gauge with isolating cock.
Supplying & fixing 63 mm dia Stainless Steel short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required : Stainless Steel (grade 304)
Supply, installation, testing and commissioning of 14 SWG MS CRCA sheet, remote ON/OFF push button enclosure, with ON / OFF indication lamps, IP 42, wall mounting type, powder coated with RAL 7032 shade/approved shade by EIC complete with internal wiring. Note: 1) ON - OFF indication lamps shall be heavy duty LED type, 240V, 50 Hz 2) PB station shall be lockable type to prevent unauthorize operation of booster pump.
TOTAL OF PART IV-C-2 : FIRE RISER & PIPING SYSTEM
PART IV-C-3 : TERRACE PUMP & ACCESSORIES
Supplying & installing completely testing & commissioning of centrifugal type fire Electric Booster pump of cast iron body and bronze/SS 316 impeller with stainless shaft complete with coupling, coupling guard necessary base frame, foundation bolts, RCC foundation, Suitable cement concrete foundation duly plastered and with anti-vibration pads. and suitable air veesel tank as rerquired size and required accesories capable of discharging 900 lt/min against 35 mtr. head against all losses complete. The scope shall also include electrical TEFC motor, operated on 3-ph, 440-V, 50 Hz, 1500 RPM Syn. speed with ‘B’ class winding, as approved by LFA. Booster Electric Pump - Motor : Discharge : 900 LPM, , Head : 35 mtr.
Design, Supply and erection of of precharged air vessel (size 450mm dia x 1500 mm height) with provision of adequate pressure switches with valves to operate as per operating sequence including 25 mm drain valve, pressure relief valve , stop cock on top, 25 mm inlet with isolation valve & the vessel shall be painted inside & outside and required all other accesories. The tank shall be fabricated from 8 mm thick MS plate with painting. The rate shall be inclusive of pressure relief/release valve of suitable pressure setting range and size.
Supply, installation, testing and commissioning of double flanged non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, Gl bolts, nuts, washers etc.as per drawing, specification and as instructed by Engineer-in-charge .
200 mm dia.
150 mm dia.
100 mm dia.
50 mm dia.
Supply, installation, testing of flanged stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes complete as per the specification and instruction of EIC.
300 mm dia.
200 mm dia.
150 mm dia.
80 mm dia.
Supply, installation, testing & commissioning of suitable Pressure switches with a suitable range (Maximum range shall not be lessthan 15 kg/sqcm and minimum shall be as per the OEM standard and site requirement) with low & high set points conforming to relevant IS specification, on air cushion tank/Pipe, complete in all respects as required and as per instructions of Engineer in charge.
Supply, installation testing and commisioning of pressure gauges of SS material with dial not less than 150 mm dia of appropriate range and complete in all respects with shut off gauge, cocks , all fittings etc, duly calibrated before installation and duly tested after installation as per drawing and as instructed by Engineer-In-Charge.
Supply, testing & commissioning of flange ends of following size PN 1.6 Expansion Bellow as per EJMA standards of overall length of minimum 200 mm, designed for 15 mm axial compression and 5 mm axial extension with tie rods etc. of following MOC & pressure ratings. MOC: Bellows: SA 240 Gr. 304, Internal Sleeve: SA 240 Gr. 304, Weldends: IS 2062 Gr. B, Flanges: IS 2062 Gr. B (Drilling as per IS 1538 /IS 6392 ) & Limit Rods & Nuts: CS - IS 1367.
TOTAL OF PART IV-C-3 : TERRACE PUMP & ACCESSORIES
PART IV-C-4 : SPRINKLER & RELATED ACCESSORIES
SITC of 5 mm standard response glass bulb type UL approved and FM approved 68 degree rated brass pendent sprinklers having 15 mm NPT connection with all accessories 5 mm glass bulb 68 deg. Pendent Sprinkler Standard Coverage 5.6 K-factor
Supply, installation, testing and commissioning of 5 mm standard response glass bulb type UL approved and FM approved 68 degree rated brass upright sprinklers having 15 mm NPT connection with all accessories 5 mm glass bulb 68 deg. Upright Sprinkler Standard Coverage 5.6 K-factor
Supply, installation, testing and commissioning of 5 mm standard response glass bulb type UL approved and FM approved 93 degree rated for Kitchen brass pendent sprinklers having 15 mm NPT connection 5 mm glass bulb 93 degree rated for Kitchen Pendent Sprinkler 5.6 K-factor
Supply, installation, testing and commissioning of test & drain assembly with all piping & sight glass including 25mm diameter 2 nos drain valve, required 25mm diameter drain pipe etc. complete as per drawing.
Providing & fixing flow switch in following sizes M.S. pipe including connection etc and compatible with fire alarm system as required. Header size : 150 mm
Providing & fixing flow switch in following sizes M.S. pipe including connection etc and compatible with fire alarm system as required. Header size : 100 mm
Supplying, installation, testing & commissioning of sprinkler flexible pipe (UL Listed) of stainless steel complete with 15 NPT on reducer thread with maximum working pressure of 175 PSI test pressure of 875 PSI (Burst) with branch line (Inlet) 25mm NPT male thread to sprinkler head (Outlet) 15mm NPT female thread with reducer, nipple, 2 side brackets, center bracket, stockbar of following sizes complete as required. 1000 MM
Supplying, installation, testing & commissioning of sprinkler flexible pipe (UL Listed) of stainless steel complete with 15 NPT on reducer thread with maximum working pressure of 175 PSI test pressure of 875 PSI (Burst) with branch line (Inlet) 25mm NPT male thread to sprinkler head (Outlet) 15mm NPT female thread with reducer, nipple, 2 side brackets, center bracket, stockbar of following sizes complete as required. 1500 MM
Providing, installation, testing & commissioning of adjustable rosette plate for 15mm dia in white finish UL Listed or FM approved complete as required.
TOTAL OF PART IV-C-4 : SPRINKLER & RELATED ACCESSORIES
PART IV-C-5 : PIPES AND RELATED ACCESSORIES
Supplying, fixing, testing and commissioning of MS seamless pipe as per ASTM A106 grade B sch 40 complete with fitting & welding of pipes & fittings wherever required complete with flanges & painting , with all the engineered support as per detail technical specification and also include design, fabrication, supply, installation, testing & commissioning of all the engineered support as per detail technical specification,supports, guides, anchors, etc. including all fresh plate, channel, angles, beams, hardwares, etc,. complete , heavy clamps, hangers, brackets or pipe supports as required including MS C class pipe of shorter lengths, tapering connecting pieces, short or long bends, MS C class specials like sockets, union nuts, elbows, reducers, plugs, Tees etc. complete to make the system operative as required by LFA/ authorities. all pipe fittings should match with class of pipes. The pipes will have to be laid and fixed on walls, ceilings, into brick walls or RCC with lead anchor fasteners. The work includes making holes in brick or RCC walls, slabs/ roofs and making good the damages by bringing to the original condition to the satisfaction of the Architect/Consultant/Client and painting two coats of approved shade(Post office red)of enamel paint over a coat of approved primer for over ground / overheads pipes Note : The piping installation has to be put to hydraulic test to1.5 times the working pressure for 2 hours & as per latest applicable code & standard before applying paint etc. complete
300 mm dia. Pipe
250 mm dia. Pipe
200 mm dia. Pipe
150 mm dia. Pipe
100 mm dia. Pipe
80 mm dia. Pipe
50 mm dia. Pipe
40 mm dia. Pipe
32 mm dia. Pipe
25 mm dia. Pipe
Supplying, installation testing and commissioning of the following ‘C’ class MS seamless pipe as per ASTM A106 grade B sch 40 complete with fitting & welding of pipes & fittings wherever required complete with flanges & painting , with all the engineered support as per detail technical specification. underground pipes with welded / flanged connection with saddles, supports as required including pipe of shorter lengths, tapering connecting pieces, short or long bends, specials like sockets, union nuts, elbows, reducers, plugs, Tees etc. complete to make the system operative as required by LFA authorities. all pipe fittings should match with class of pipes. the pipes will have to be laid and fixed in trenches. making holes in brick or RCC walls, slabs/ roofs and making good the damages by bringing to the original condition to the satisfaction of the Architect and painting two coats of approved shade(Post office red)of enamel paint over a coat of approved primer for over heads pipes and providing and fixing pypkote (corrosion protection tape) including supply and application of pipe coating and spiral Wrapping for underground piping (wrapping should have overlap of 15 to 20 mm) etc. complete as per ASTM standards/IS:10221 for corrosion protection of pipes for the under ground installation.
Note : The piping installation has to be put to hydraulic test to1.5 times the working pressure for 2 hours & as per latest applicable code & standard before applying paint etc. complete 250 mm dia. Pipe
250 mm dia. Pipe
200 mm dia. Pipe
150 mm dia. Pipe
100 mm dia. Pipe
80 mm dia. Pipe
Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required : 2 way-100 mm dia M.S. Pipe
Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required : 4 way-150 mm dia M.S. Pipe
SITC of fire brigade draw out connection with 100 mm MS suction pipe and 100 mm dia Cast iron foot valve. The scope shall also include required valves, piping, M.S cabinet as required.
TOTAL OF PART IV-C-5 : PIPES AND RELATED ACCESSORIES
PART IV-C-6 : FIRE PUMP & RELATED ACCESSORIES
Supplying & installing completely testing & commissioning of centrifugal main fire pump(electrical driven) for hydrant main / sprinkler main with cast iron casing & bronze impeller & internal parts, make as approved by ISO/CFO for fire duty, complete with coupling, coupling guard necessary base frame, foundation bolts, RCC foundation, antivibration paid , capable of discharging 2850 lt/min against 90 mtr. head against all losses complete. The scope shall also include electrical TEFC motor, operated on 3-ph, 440-V, 50 Hz, 1500 RPM Syn. speed with ‘B’ class winding, make as approved by LFA. The pump shall be capable of giving not less than 150% discharge at a head not less than 65% of the rated head and complete as per specification and instruction of EIC.
Supplying & installing completely testing & commissioning centrifugal main fire pump (diesel driven)with cast iron casing & bronze or phosphor bronze internal parts, make as approved by ISO/CFO for fire duty, complete with coupling, coupling guard necessary base frame, foundation bolts, RCC foundation,antivibration paid , capable of discharging 2850 lt/min against 90 mtr. head against all losses complete with suitable diesel engine of speed matching the pump speed ,auto start facility with battery & battery charger, necessary wiring, fuel tank ,exhaust system, foundation gauges & wired for automatic start of the water pump on drop of pressure in the hydrant and sprinkler system. The pump should confirm to LFA / SEB & and IE Regulations. The pump shall be capable of giving not less than 150% discharge at a head not less than 65% of the rated head and complete as per specification and instruction of EIC. Pump - Diesel Engine : Discharge : 2850 LPM, Head 90 mtr
Supplying, installing, testing and commissioning of Vetrical Centrifugal jockey pump-motor with discharge 180 lpm against 90 mtr. head with 3 phase, 415 V, 50 Hz motor having 2900 RPM, complete with coupling, coupling guard necessary base frame, foundation bolts, RCC foundation,antivibration paid , as per site conditions and instructions of site engineer-in-charge including proper fixing, The electrical motor for the pump should comply as per Specification. The scope shall also include necessary coupling, coupling guard, base frame, foundation bolts, RCC foundation, etc. complete as per specification and instrudction of EIC. Pump - Motor : Discharge : 180 LPM, Head : 90 mtr.
SITC of precharged MSEP air vessel (size 600mm dia x 2000 mm height) with provision of adequate pressure switches with valves to operate as per operating sequence including 25 mm drain valve, pressure relief valve , stop cock on top, 25 mm inlet with isolation valve & the vessel shall be painted inside & outside. The tank shall be fabricated from 8 mm thick MS plate with painting. The rate shall be inclusive of pressure relief/release valve of suitable pressure setting range and size. Air Vessel : 600 mm dia x 2000 mm h
Supply, testing & commissioning of flange ends 150mm diameter C.I woltman water flow meter confirming to ISO 4064 class-B( inline) with factory calibrated, , flanged connection, flow mete with all accessories complete as per following specifications including fixing using flanged specials with bolts, nuts & packing with testing. Scope also including testing and commissioning complete as per standard design as per detail technical specification etc. complete as per standard as directed by Engineer-in-charge to complete the job.
TOTAL OF PART IV-C-6 : FIRE PUMP & RELATED ACCESSORIES
PART IV-C-7 : High velocity water spray system for 2500 KVA Transformer.
Providing, fixing, testing and commissioning of 80mm diameter Deluge valve conforming to UL Listed PN 30 tested to 1.5 times working pressure with necessary companion flanges,complete assmebly , Horizontal/Vertical mounting, Ductile Iron body, Aluminium bronze Clapper and Latch, EPDM Clapper seal, Nitrile rubber bushing and seat O ring, S.S Shaft and EPDM diaphragm complete with electric release trim assembly for deluge valve with two way solelnoid valve, weather proof operation on 24 volts DC supply complete, Hydraulic Release trim, including all necessary accessories.
Supplying, Installation, Testing and commissioning of High velocity Water Spray Nozzle (HVW Spray Nozzles) , Model (HV-BS), MAT (STAINLESS STEEL CONSTRUCTION ASTM CF8M) SIZE(20NB) K(23) ANGLE(120°) END CONNECTION (3/4" NPT MALE) APPROVALS UL Listed & FM Approved FINISH (NATURAL)
Providing, fixing, testing and commissioning of Quartzoide Bulb Detector (QBD) - with 15mm Screwed end connection K 5.6 Rating 79 Deg. C, UL Listed with required accessories UL Listed & FM Approved in Chrome Plated Brass Constrn.
Supplying, Installation, Testing and commissioning of Electrical Solenoid Valve, Weather Proof, 24 VDC -1/2" NPT(F)
Supplying, Installation, Testing and commissioning of Pressure switch for HVW system including all necessary accessories.
Supply, Installation, Testing and Commissioning of Deluge Valve Local control Panel consisting of Panel (Relays and Interface Units considered in FDA BOM) fabrication MS 16 SWG, CRCA sheet, panel cubical, front access, wall mounting, bottom side cable entry, indoor type IP 54, MCB 6 Amp, 24V DC 1 Amp SMPS Power Supply, Glass fuse 2 Amp, 24V DC 8 pin relay with base, Push button for Manual & Test mode with break glass, Connector 4 sq.mm, Power & control wiring laying, termination 1 sq.mm, Incoming power cable for panel - 3 core x 1.5 sq.mm copper armoured FRLS cable, Double compression brass cable gland etc. complete as per specification/drawings and as directed by Architect / Engineer in charge .
Supplying, Installation, Testing and commissioning ERW MAT(MILD STEEL) MAT STD(IS-1239) pipe GR(HEAVY) SIZE(65 NB) for Pylon support including all necessary supprots, clamps and accessories.
Supplying, Installation, Testing and commissioning of Addressable Monitor module including all necessary accessories.
Supplying, Installation, Testing and commissioning of Addressable Control module including all necessary accessories.
Supplying, Installation, Testing and commissioning of Power supply unit including all necessary accessories.
Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Copper conductor with water swellable coating which should protect against saline water & 1.1 KV. to be laid on wall with necessary clamps or in existing trench / pipe at road crossing or floor of following size of cable. 2C X 1.5 sq.mm cable
TOTAL OF PART IV-C-7 : High velocity water spray system for 2500 KVA Transformer.
PART IV-C-8 : CIVIL ITEMS - FFTG Valve Chamber
Depth not exceeding 1.5 m from ground level
Depth exceeding 1.5 m & up to 3.0m from ground level
Providing and laying in position, at all locations & depths, plain cement concrete of grade as specified below including machine mixing, consolidation, finishing, curing and including cost of form work, shuttering, centering etc. complete all as per specifications and directed by EIC. (Note:- Reinforcement provided if any shall be measured & paid under relevant item.)
Concrete of M10 grade
Providing and laying in position, at all levels & loactions, for structural members of all geometrical shape & design as per drawing, Reinforced Cement Concrete (RCC) of grade as specified below, conforming to latest revisions of IS:456-2000 and IS:13920, using 20 mm maximum size aggregates and approved quality sand including admixtures of approved brand and quality (plasticisers / super plasticisers), weigh batching, mechanical mixing, transporting, placing, vibrating, consolidation, finishing, curing etc.complete all as per specifications & as directed by EIC.
Reinforced cement concrete of Grade M-25
Extra for providing RMC (Ready Mixed Concrete) conforming to IS:4926 (Latest revision) in lieu of site batch mix RCC & PCC items, supplied by approved RMC manufacturers including transportation, pumping etc.complete all as per specifications and as directed by EIC.
Providing, erecting, fixing in position, striking / removing and cleaning steel / timber shuttering & centering for form work including single / multiple staging at all floors, level & locations for all geometrical shapes in plain, curved surfaces of structural / R C C elements and including rails, bracings, props, brackets, cutting holes for pipes etc., providing & applying approved form oil on all surfaces of form work coming in contact with concrete including close hacking of all exposed concrete work after removal of form work, all materials, labour etc. complete as per specifications, drawings & as directed by the Engineer-in-Charge. (Area of form work in contact with concrete shall only be measured for payment & stop boards for construction joints etc. will not be measured for payment).
For all type of structural / RCC elements including all geometrical shapes and single / multiple staging at all floors and location For Below Plinth Level (In Sub Structure)
Reinforcement for RCC work including supplying, delivering, storing of various diameters as required at site of work including loading, unloading, transporting, decoiling, straightening, cutting, bending, placing in position at all floors, locations & levels and binding with 18 gauge, soft drawn annealed steel binding wire including carrying out various tests as required etc. all as per specifications, drawings & as directed by the Engineer-in-Charge. (Note: The cost of binding wire shall be borne by the contractor and binding wire shall not be measured for payment.)
For Below Plinth Level (In Sub Structure) Thermo Mechanically Treated bars of grade Fe-550 D, manufactured by SAIL, TATA STEEL, JSW, JSPL and RINL only.
Extra over above item for using Thermo Mechanically Treated Bar of grade CRS (Corrosion Resistant Steel) Fe-550 D in place of Thermo Mechanically Treated bars of grade Fe-550 D.
Brick masonry work using well burnt bricks from approved lot of class designation 7.5 (classification as per IS:1077-1992 and min. average compression strength not less than 7.5 N/mm2) using ready mixed cement sand mortar (1.4), to correct line, level and plumb including raking out joints & simultaneous flush pointing using ready mixed cement sand mortar (1.4), curing, scaffolding all as per specifications, drawings and as directed by Engineer in charge.
Providing 15 mm thick Cement plastering work in single coat using ready mixed cement sand mortar (1:4) and finished smooth with neat cement punning, at all levels, locations & depth, over concrete/ masonry surface including surfaces preparation, even & smooth surface in correct line, level, plane, plumb and including scaffolding, curing etc complete all as per specifications and as directed by EIC. (For Inside trenches, Nallah, Pit, Storm water drain, Chambers, steps etc.)
150 mm consolidated thickness
Providing & fixing precast approved brand FRP Composite Manhole covers as approved by Competent authority / E.I.C tested as per IS:1726, including cost of necessary hardware, 1:2:4 grade concrete for fixing frame, bed block (bearing course) and capping including necessary form work and CM 1:2 mortar for fixing the frame & for plastering exposed surfaces of concrete bed block (bearing course) and capping finished smooth with floating coat of neat cement etc., complete as per specifications, drawings and as directed by the E.I.C. Square Recessed Heavy duty (Grade HD - 20 designation as per IS:1726/ C-250 as per EN124 or higher loading class) frame and cover of Size 600mm X 600 mm/ 900mm X 900mm/ As per mentioned in Drawing. Note: Shade and Colour and design pattern to be get approved from Engineer-in-Charge.
Providing and fixing copolymer polypropylene steel reinforced plastic Foot-rests / Steps of approved brand or eq. as per ASTM D - 4101 specification and moulded a 12 mm dia. IS - 1786 grade Fe - 415 steel reinforcing bar and in "U" shape having dimensions 263 x 168 mm and fixing in concrete / wall as shown in the drawing and as directed all complete
Total of PART IV-C-8 : CIVIL ITEMS - FFTG Valve Chamber
TOTAL OF PART IV-C (FIREFIGHTING SYSTEM)
DEE VEE PROJECTS LIMITED
KMV PROJECTS LIMITED
Varindera Constructions Limited
KPC PROJECTS LIMITED
URC Construction (P) Ltd
KEC International Ltd
Renaatus Projects Private Limited
Varindera Constructions Limited
KEC International Ltd
KPC PROJECTS LIMITED
KMV PROJECTS LIMITED
URC Construction (P) Ltd
Renaatus Projects Private Limited
Varindera Constructions Limited
KEC International Ltd
KPC PROJECTS LIMITED
KMV PROJECTS LIMITED
URC Construction (P) Ltd
KPC PROJECTS LIMITED
Renaatus Projects Private Limited
DEE VEE PROJECTS LIMITED
KMV PROJECTS LIMITED
KEC International Ltd
URC Construction (P) Ltd
KPC PROJECTS LIMITED
Renaatus Projects Private Limited
DEE VEE PROJECTS LIMITED
KMV PROJECTS LIMITED
KEC International Ltd
URC Construction (P) Ltd
Renaatus Projects Private Limited
KPC PROJECTS LIMITED
KMV PROJECTS LIMITED
Varindera Constructions Limited
URC Construction (P) Ltd
KEC International Ltd
Renaatus Projects Private Limited
KPC PROJECTS LIMITED
KMV PROJECTS LIMITED
Varindera Constructions Limited
URC Construction (P) Ltd
KEC International Ltd
URC Construction (P) Ltd
Renaatus Projects Private Limited
DEE VEE PROJECTS LIMITED
KEC International Ltd
KPC PROJECTS LIMITED
Varindera Constructions Limited
URC Construction (P) Ltd
Renaatus Projects Private Limited
DEE VEE PROJECTS LIMITED
KEC International Ltd
KPC PROJECTS LIMITED
Varindera Constructions Limited
URC Construction (P) Ltd
Renaatus Projects Private Limited
DEE VEE PROJECTS LIMITED
KPC PROJECTS LIMITED
KEC International Ltd
Varindera Constructions Limited
URC Construction (P) Ltd
Renaatus Projects Private Limited
DEE VEE PROJECTS LIMITED
KPC PROJECTS LIMITED
KEC International Ltd
Varindera Constructions Limited
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.16 MB
RFPDetailedNIT1.pdf
Tender Documents • 2.44 MB
AdditionalTechlSpec.pdf
Tender Documents • 3.88 MB
NITSummary1.pdf
Tender Documents • 0.15 MB
BOQ_860288.xls
BOQ • 2.14 MB
Download all tender documents and submit your bid