| Sl No | Description | Qty | Unit | Sagar Chakraborty L1 |
|---|---|---|---|---|
| 1.00Civil Works | ||||
| 1.01 | Dismantling tile work in floors and roofs laid in cement mortar including stacking material within the campus as directed by Engineer in Charge. For thickness of tiles above 25 mm and up to 40 mm | 145.5 | sqm | 100 ₹14,550 Lowest |
| 2.00 | Dismantling aluminium/ Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable material and stacking of serviceable material with in 50 meters lead as directed by Engineerin-charge. | 173.2 | sqm | 100 ₹17,320 Lowest |
| 3.00 | Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge. | 12.4 | cum | 1,500 ₹18,600 Lowest |
| 4.00Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : | ||||
| 4.01 | 1:2:4 (1 cement : 2 coarse sand (zone-ill) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) | 5.85 | cum | 5,000 ₹29,250 Lowest |
| 5.00 | Damproofing in walls Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. | 64.8 | sqm | 100 ₹6,480 Lowest |
| 6.00 | Providing and laying water proofing treatment in wall of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : (a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours. (b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. | 64.8 | sqm | 600 ₹38,880 Lowest |
| 7.0012 mm cement plaster of mix : | ||||
| 7.01 | 1:4 (1 cement: 4 fine sand) | 83.8 | sqm | 200 ₹16,760 Lowest |
Tender Value
₹28.2 L
EMD Value
₹56,500
Closing Date
20 Oct 2025, 11:00 amClosed
HOS MAINTENANCE
IPM SECTION, IIT GUWAHATI
Repair and renovation of Usability Engineering Laboratory at Core-1 of Design Department in Academic Complex
2025_IITG_881234_1
IITG/IPM/NIT/R/2025-26/50
Open Tender
Civil Works
Works
120 days
IIT GUWAHATI
Please refer Tender documents.
2 documents required · 2 mandatory
₹2,000
IIT GUWAHATI
₹56,500
12 Dec 2025
14 Oct 2025
21 Oct 2025
14 Oct 2025
20 Oct 2025
14 Oct 2025
Amount
Civil Works
Dismantling tile work in floors and roofs laid in cement mortar including stacking material within the campus as directed by Engineer in Charge. For thickness of tiles above 25 mm and up to 40 mm
Dismantling aluminium/ Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable material and stacking of serviceable material with in 50 meters lead as directed by Engineerin-charge.
Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :
1:2:4 (1 cement : 2 coarse sand (zone-ill) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources)
Damproofing in walls Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead.
Providing and laying water proofing treatment in wall of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : (a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours. (b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.
12 mm cement plaster of mix :
1:4 (1 cement: 4 fine sand)
Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level.
Cement mortar 1:3 (1 cement :3 coarse sand)
12 mm cement plaster finished with a floating coat of neat cement of mix :
1:3 (1 cement: 3 fine sand)
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and einforcement - All work up to plinth level :
1:1.5:3 (1 cement : 1.5 coarse sand (zone-ill) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.
Thermo-Mechanically Treated bars of grade Fe-500D or more. kg 107.85 5.22B Steel reinforcement
Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement: 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing of edges to give high gloss finish etc. complete at all levels.
Granite stone slab of colour black, Cherry/Ruby red
Area of slab upto 0.50 sqm
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.
75 mm diameter
Cutting holes of required size in brick masonry wall for fixing of exhaust fan including providing and fixing 300 mm dia PVC pipe conforming BIS-12818 and making good the same etc. complete as per direction of Engineer-incharge.
Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms.
15 mm nominal bore
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in charge. (Glazing, paneling and dash fasteners to be paid for separately) :
For fixed portion
Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15)
For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately)
Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15)
Reassembling and fixing of existing aluminium partition and Glazing work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in charge
Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer-in-charge.
Pre-laminated particle board with decorative lamination on both sides
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):
With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm)
Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content.
With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre
Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour.
two coat or more coat
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete.
Size of Tile 600x600 mm
Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on interlocking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main “T” runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross “T” of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main “T” at 600 mm center to center to form a grid of 1200x600 mm and secondary cross “T” of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main “T” runners to be suspended from ceiling using Gl slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm Gl adjustable rods with galvanized butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge.
8 mm thick fully perforated calcium silicate board made with Calcareous & Siliceous materials reinforced with cellulose fiber manufactured through autoclaving process to give stable crystalline structure with minimum compressive strength 225 kg/ sq. cm, bending strength 100 kg/sq. cm , of size 595x595 mm, having perforation of dia. 10 mm with minimum perforated area 18 % with non woven tissue on the back side, having an NRC ( Noise Reduction Coefficient) of 0.85, with 50 mm thick rockwool of 48 kg /cum backing.
Providing and laying factory made FRP Gratings as per direction of Engineer in Charge (Grating size 1220 mmx450 mmx38 mm, mess size 38 mmx38 mm) Pcs 37.00 4500.00 1,66,500.00
AC Works
Supply installation Testing commssioning 3 TR inverter vertical tower AC to be run at 415volt/3phase/50Hz air flow volume (wet CFM)(high/low) 877/704 with rotary or scroll compressor and with first charge of refrigent R410A and LED remote with night glow function at remote buttion witn suction tube outer dia 19.5mm specification as per All specifications as per IS1391 (Part 2): 1992 Room air-conditioner
Supply installation of copper piping as per the size of the machine etc. complaete as required
Supply installation of pvc insulated 4 core 4 sq mm communication cable as per the machine specificaton
Supply instllation testing and commissioing of 1.5 TR 5 star rated Split Inverter type room Air Conditioner (For Cooling) having Rotary -R410a/R32 Compressor, Power supply 230V AC, 50HZ, Power Input:1600W or less, Running current :7.3 amp or less, Speed setting (Cooling/Fan): 4/3, also having features of LDC Remote Operating Control, Electronic Thermostat, Oscillating Lovers, auto air swing, Auto Start, ON/OFF timer, Dehumidification, Sleep mode etc complete as required
Supply and installation of Starter Switch
Supply and installation of Clamp for Outdoor Unit Fitting
Supply and installation of Copper pipe beyond 4 meter length
Supply and installation of Drain pipe 25mm dia CPVC inlcuding nitrile insulation complete as required
Supply of 15 amp Plug Top
Providing and laying of in position cement concrete of specified grade excluding the cost of centering and shuttering- All work upto plinth level
1:4:8 (1 cement: 4 coarse sand (zone-III): 8 graded stone aggregate 40 mm nominal size) for base of the pedestial and miscellaneous works
Dismantling aluminium/ Gypsum partitions, GI ductings, doors, windows, fixed glazing and false ceiling including disposal of unserviceable surplus material and stacking of serviceable material within 50 meters lead as directed by Engineer-in-charge.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required
2 X 4 sq. mm + 1 X 4 sq. mm earth wire
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
6 pin 15/16 A socket outlet
Supplying and , fixing of following modules GI boxes along with modular base & cover plate for modular switch in recess etc as required
1 or 2 Module
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Single pole
Supply, Installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, support etc. as per approved drawing and specifications of following sheet thickness complete as required.
thickness 0.63 mm sheet
Supplying & fixing of powder coated extruded aluminium Supply Air Grills with aluminium volume control dampers as per specifications.
Supplying & fixing of powder coated extruded aluminium Return Air Grills with louvers but without volume control dampers complete as required.
Supplying & fixing of supply air diffusers of powder coated extruded aluminium with aluminium volume control dampers with anti sumg ring & removable core as per specifications.
Supplying & fixing of return air diffusers of powder coated extruded aluminium without volume control dampers with anti sumg ring & removable core as per specifications.
Supplying and fixing of following thickness duly laminated aluminum foil of mat finish closed cell Nitrile rubber (Class "O") insulation on existing duct after applying suitable adhesive for Nitrile rubber. The joints shall be sealed with 50 mm wide and 3 mm thick self adhesive nitrile rubber tape insulation complete as per specifications and as required.
Electrical Works
Wiring for circuit /submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required
i) 2x4 sqmm + 1x4 sqmm earth wire.
i) 2x1.5 sqmm + 1x1.5 sqmm earth wire.
Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required
1 module
3 module
6 module
8 module
12 module
Supplying and drawing of UTP 4 pair CAT 6 LAN cable in the existing surface / recessed steel / PVC conduit as required
1 run of cable
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box inclding connections but excluding modular plate etc. as required.
3 pin 5/6 A socket outlet
5/6 A Switch
Telephone Socket Outlet
6 pin 15/16A Socket outlet
15/16A switch
Supplying and fixing 5A to 32A rating, 240/415V,10KA, "C" curve,miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required
Single pole
Supplying and drawing following pair 0.5mm dia FRLS PVC insulated annealed copper conductor, unarmoured telephone cable in the existing surface/recessed steel/PVC conduit as required
Supply and Install of 36W LED 2 X 2 surface light fitting as per approved brands. (Approved Make /Phillips/Havells/CG/Bajaj)
Supply and Install of 18 W LED 1 X1 surface light fitting as per approved brands.(approved make -/Phillips/Havells/CG/Bajaj)
Supplying and fixing of computer point RJ-45 modular type in compatiable box along with cover plate etc. complete make legrand or equivalent
Supply and Installation of Hanging Lights 36W Crompton CAT Ref : LSCUR4-36-CDL or equivalent
supply of five star rated Exhaust fan, 300mm Light duty Make -Havells/Crompton Greeves
supply of five star rated 450mm sweep wall bracket fan
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.62 MB
NIT.pdf
Tender Documents • 0.41 MB
BOQ_926241.xls
BOQ • 0.37 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .