Loading…
Loading…
Tender Value
₹2.1 Cr
EMD Value
₹1.5 L
Closing Date
13 Mar 2026, 5:00 pmClosed
Similar tender results from the same govt authority in the past 3 years.
MR Yognarayan sahu(DFLT)
CE(Raipur)
CONSTRUCTION OF (BALANCE WORK) HOSTEL BUILDING(4th & 5th FLOOR) FOR GIRLS AT GOVT. MEDICAL COLLEGE RAPIUR I/C. ELECTRIFICATION WORK. DIST. RAIPUR(DN. NO.2, RAIPUR).
186320
NIT No. 1017/TC/2025-26
RESTRICTED TENDER
WORKS
8 days
CE(Raipur)
Required Past Technical Experience: AS PER NIT
Required Financial Turnover (in INR): AS PER NIT
Required Bid Capacity (in INR): AS PER NIT
6 documents required · 6 mandatory
Public Works Department (PWD)
WORKS
MR Yognarayan sahu(DFLT)
RESTRICTED TENDER
PERCENTAGE
A B
CE(Raipur)
PWD Circle-1,Raipur
PWD Div No2 Raipur
120
08
No
0
186320
13 Mar, 2026 5:00:00 PM IST
18 Mar, 2026 10:00:00 AM IST
25 Feb, 2026 5:00:00 PM IST
NIT No. 1017/TC/2025-26
CONSTRUCTION OF (BALANCE WORK) HOSTEL BUILDING(4th & 5th FLOOR) FOR GIRLS AT GOVT. MEDICAL COLLEGE RAPIUR I/C. ELECTRIFICATION WORK. DIST. RAIPUR(DN. NO.2, RAIPUR).
150000.00 INR
RTGS/CHALLAN (ONLINE) Internet Banking (ONLINE)
21430000.00
2
17 Mar, 2026 5:00:00 PM IST
21430000
AS PER NIT
AS PER NIT
AS PER NIT
0.00 INR
15d 19h 55m
6 documents required · 5 mandatory · 1 optional
₹0
₹1.5 L
25 Feb 2026
25 Feb 2026
18 Mar 2026
25 Feb 2026
13 Mar 2026
25 Feb 2026
17 Mar 2026
Carriage by mechanical transport upto 5 km lead: 1.26.3 - Dismantled Building debris (Mulba)
Providing and fixing formwork including centering, shuttering, strutting, staging, propping bracing etc. complete and including its removal at all levels, for : 2.1.5 - Columns, Pillars, Piers and likes- rectangular or square in shape
Suspended floors, roofs, access platform, balconies (plain surfaces) and shelves (cast in situ)
Beams, lintels, cantilevers & walls
Weather shades, Chhajja, Cornices & Moulding
Stair cases of all types excluding spiral and folded plate type, including risers and landings
Providing and laying design mix reinforcement cement concrete with crushed graded stone aggregate 20mm nominal size using batching plant, transit mixer and concrete pump, in all works upto floor five level excluding cost of reinforcement and form work. 3.3.2 - M-25 (using minimum cement 410 kg/cum concrete)
Providing and placing in position reinforcement for R.C.C. work including straightening, cutting, bending, binding etc. complete as per drawings including cost of binding wire all complete: 3.12.1 - Thermo-Mechanically treated bars
Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of WC, kitchen and the like consisting of: i) 1st course of applying cement slurry @ 4.4 Kg/sqm mixed with water proofing compound conforming to IS 2645 including rounding off junction of vertical and horizontal surface. ii) 2nd course of 20mm cement plaster 1:3 (1 cement : 3 coarse sand) mixed with water proofing compound including rounding off junction of vertical and horizontal surface. iii) 3rd course of applying blown or residual bitumen applied hot @ 1.7 Kg. per sqm of area. iv) 4th course of 400 micron thick PVC sheet. (Overlaps at joints of PVC sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 Kg. per sqm of area.
Brick work with modular fly-ash lime bricks (FaLG Bricks) confirming to IS:12894-2002 of class designation 4.0 in foundation and plinth in: 7.5.3- Cement Mortar 1:5 (1 cement : 5 coarse sand)
Extra for brick work in superstructure above plinth level for every floor or part thereof in addition to rate for foundation and plinth:
Extra for brick work in superstructure above plinth level for every floor or part thereof in addition to rate for foundation and plinth:
Extra for brick work in superstructure above plinth level for every floor or part thereof in addition to rate for foundation and plinth:
Half brick thick brick masonry with fly-ash lime bricks (FaLG Bricks) confirming to IS:12894-2002 of class designation 4.0 in superstructure above plinth level upto plinth level: 7.11.2 - Cement Mortar 1:4 (1 cement : 4 coarse sand)
Extra for providing and placing in position hopping 25x1.60 mm or 2 Nos 6mm dia MS bars reinforcement at every third course of half brick masonry.
Extra for half brick work in superstructure above plinth level for every story or part thereof in addition to rate for upto plinth level: Fourth Floor
Fifth Floor
Providing and fixing flush door shutters, conforming to IS 2202 (Part 1), interior grade, commercial type, core of block board construction with frame of first class hard wood and well matched commercial ply veneering with vertical grains, cross bands and face veneers on both faces of shutters excluding hinges. 8.13.2 - 35 mm. thick (single leaf)
25 mm. thick (double leaf for cupboard shutters with piano type hinges
Extra for double leaf shutter instead of single leaf.
Providing and fixing lipping with second class teak wood lipping on all edges of shutters. 8.18.1- 25 x 6 mm size
Providing 40x5mm iron hold fast 40cm long including fixing to frame with 10mm bolts nuts and wooden plug and embedding in Cement Concrete 1:2:4 in blocks of size 30x10x15cm.
Providing and fixing stainless steel sliding door bolts with 16mm rod, 2.5mm thick flap, necessary stainless steel nuts bolts and screws etc complete. 8.137.1- 300mm
Providing and fixing stainless steel butt hinges IS : 12817 marked with necessary stainless steel screws etc complete. 8.132.2- 125x2.5mm (heavy)
Providing and fixing stainless steel door latch with 12mm rod, 2.5mm thick flap, necessary stainless steel screws etc complete. 8.138.2 - 250mm
Providing and fixing stainless steel tower bolts (Barrel type) with necessary stainless steel screws etc complete. 8.139.1- 250 x10mm
Providing and fixing stainless steel door handles having flap thickness 2.5mm, necessary stainless steel screws etc complete. 8.140.2- 125 mm
Providing and fixing 150mm bright finished brass floor door stopper with rubber cushion & brass polished MS screws etc complete to suit the shutter thickness. 8.144.2 - 75 mm long
Providing and fixing magnetic catcher in cupboard / ward robe shutters including fixing with necessary screws etc. complete. 8.145.1- Triple strip vertical type.
Providing and fixing special quality bright finished brass cupboard or wardrobe locks with four levers including necessary screws etc. complete (best make of approved quality) : 8.71.2 - 50 mm
Providing and fixing factory made UPVC door frame made of UPVC profile section having an overall dimension as below (tolerance ± 1mm) with wall thickness 2.0mm ± 0.2mm, corners of the door frame to be jointed with galvanized brackets and stainless steel screws, joints mitred and plastic welded. The hinge side vertical of the frames reinforced by galvanized M.S. tube of size 19 X 19mm and 1mm ± 0.1mm wall thickness and 3 nos. stainless steel hinges fixed to the frame complete as per manufacturers specification and direction of Engineer-in-charge 8.148.2 - Extruded section Profile size 42x50 mm
Providing and fixing factory made PVC door shutters of specified thickness made of styles and rails of a UPVC hollow section of specified size 59x24 mm and wall thickness 2 mm ± 0.2 mm with inbuilt edging on both sides. The styles and rails mitred and joined at the corners by means of M.S. galvanised/ plastic brackets of size 75x220 mm having wall thickness 1.0 mm and stainless steel screws. 8.149.2- 30 mm thick door shutters with styles and rails of size 60x30 mm
Steel work in tubular (round, square or rectangular hollow tubes etc.) structure in built-up sections, trusses and frame work including cutting,hoisting, fixing in position upto a height of 5m above plinth level, consisting of columns trusses, roof and bottom purlins, base plate, holdingdown bolts, wind ties bracing (if required), bolts, nuts and washers for fastening etc. complete with applying a priming coat of red oxide zinc chromate primer. 9.3.2- Electric resistance or induction butt welded tubes Grade-300
Providing and fixing steel door/ window with M.S. sheet 1mm thick, frame of angle iron, diagonal braces of angle/ flat iron of suitable size, 3.00 mm M.S. gusset plates at junctions and corners, all necessary fittings complete including applying a priming coat of red oxide zinc chromate primer
Providing and fixing M.S. grill of approved pattern made of M.S. flats or square or round bars welded to steel frame of windows etc. including applying a priming coat of red oxide zinc chromate primer..
Providing and fixing aluminium work for doors, windows, ventilators and partitions made out of extruded aluminium standard sections (main section with minimum 1.5mm thickness) conforming to IS: 733, IS: 1285 mitred and jointed mechanically including aluminium cleats, neoprene weather stripping gasket beveled edge beading, screws duly fixed in wall/ floor with fixing clips or hold fasteners or bolts and nuts as required aluminium sections shall be anodized transparent or dyed to approved shade according to IS: 1868, minimum anodic coating shall be of grade AC-15. (Glazing and panelling to be paid for separately 9.47.1 - For fixed portion
For shutter of doors, windows & ventilators including providing and making provision for fixing of fitting wherever required including the cost of PVC/ neoprene gasket required (Fittings shall be paid for separately).
meter
Raised Band
Providing and fixing chicken mesh weighting not less than 250 gms/ sqm as per IS : specification in the required width with 10mm long steel nails on vertical and horizontal surface near R.C.C. and brick walls junctions including scaffolding and all lead and lifts etc. complete before plastering upto 10mts in height.
Providing and mixing in cement mortar, triangular polyester fiber Recron 3s (Anti-shrinkage Admixture) of 6 mm length of approved make like Reliance industries Ltd etc. in proportion as recommended by manufacturer.
Cement concrete flooring with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm) finished with a floating coat of neat cement.. 12.3.3 - 75 mm thick
Cement plaster skirting upto 30 cm. height with cement mortar 1:3 (1 cement : 3 fine sand) finished with a floating coat of neat cement including rounding of junction with floor. 12.6.1- 18 mm thick in two layers of 12mm and 6mm
Providing and fixing rectified glazed ceramic glazed wall /dado tiles of 1st quality conforming to IS : 15622-2017 of approved make, colour, shade laid on 20 mm thick Cement Mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @3.3kg per sqm including pointing the joints with white cement mixed with matching pigment etc., complete. 12.75.1 - Size 300x450 mm Thickness 7 to 8 mm
Providing and fixing rectified glazed ceramic floor tiles of 1st quality conforming to IS : 15622-2017 of approved make, colour, shade laid on 20 mm thick Cement Mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @3.3kg per sqm including pointing the joints with white cement mixed with matching pigment etc., complete. 12.74.1 - Size 300x300 mm thickness 7 to 8mm
meter
Extra for providing edge moulding to 15mm thick stone counters, vanities etc. including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. 13.19.2 - Granite work
Providing and fixing both side polished 30 mm thick RAJIM SAND STONE shelves fixed in walls in cement mortar 1:3 (1 cement : 3 coarse sand) including finishing complete.
Applying one coat of cement primer on wall surface (applied @ 0.80 litrs/10 sqm) complete.
Painting on new work (two or more coats) to give an even shade with: 14.22.2 - Premium synthetic enamel paint
Demolishing brick masonry including arches, stacking of serviceable material disposal of unserviceable material within 50 metres lead. 16.3.3 - In cement mortar
Dismantling G.I. sheet roofing including ridges hips, valleys and gutters etc. and stacking the material with 50 m lead.
Demolishing cement concrete including disposal of material within 50 metre lead. 16.43.2 - 1:3:6 or richer mix
Providing and fixing 10 litre capacity P.V.C. low level flushing cistern conforming to IS : 7231, with all fittings and fixtures complete. 18.7.1- White
Providing and fixing vitreous china wash basin with C.I. brackets, 32 mm C.P. brass waste of standard pattern, including painting of brackets, cutting and making good the walls wherever required : 18.17.2 - White Size 550x400 mm
Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink with drain board as per IS 13983 with C.I. brackets and stainless steel plug 40 mm including painting of fittings and brackets, cutting and making good the walls wherever required : 18.21.1- 1145x510 mm bowl size 560x410x241 mm
Providing and fixing white vitreous china laboratory sink including making all connections excluding cost of fittings: 18.24.2 - Size 600x450x200 mm.
Providing and fixing cast iron grating for gully trap. 18.27.1- 100x100mm square or round
Providing and fixing 600x450 mm beveled edge 4mm mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
Providing and fixing sand cast iron S&S trap of self cleansing design with screwed down or hinged grating with or without vent arm as per IS: 1729 complete, including cost of cutting and making good the walls and floors : 18.56.1 - 100 mm inlet and 100 mm outlet
100 mm inlet and 75 mm outlet
Providing and fixing on wall face UV stabilized Unplasticised Rigid PVC pipes (single socketed) having 3.2mm wall thickness conforming to IS : 13592 (4kg/sqcm) including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. 18.76.1- 75 mm dia pipe.
110 mm dia pipe.
150 mm dia pipe
Providing and fixing on wall face UV stabilized Unplasticised - PVC moulded fittings/ accessories having 3.2mm wall thickness for Rigid PVC pipes conforming to IS : 13592 (heavy) jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. 18.77.1 - Tee/ Tee with door/ Bend 45°/ Bend 90° 18.77.1.1 - 75 mm
Double "Y" with or without door 18.77.2.1 - 75mm
vent covel 18.77.3.1 - 75 mm
Access door cap 18.77.4.1 - 75 mm
Nahani trap 110x75mm
Multi floor trap 110
Providing and fixing UV stabilized Unplasticised -PVC pipe clips of approved design to Rigid PVC pipes by means of 50x50x50mm hard wood plugs, screwed with M.S. screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 18.78.1 - 75 mm
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. CONCEALED WORK including cutting chases and making good the walls etc., 19.5.2 - 20 mm nominal outer dia .Pipes.
25 mm nominal outer dia .Pipes.
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This included jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. EXTERNAL WORK 19.6.2 - 120 mm nominal outer dia pipes
25 mm nominal outer dia pipes
32 mm nominal outer dia pipes
40 mm nominal outer dia pipes
50 mm nominal outer dia pipes
Long body bib cock (500gms)
Stop cock (concealed) (600gms)
Angle valve for basin mixer and geyser points (450gms)
Bottle trap set with extension pipes
Toilet paper holder
Soap dish plate
Shower rose (revolving type) (150mm)
Towel rail (600mm long x 20mm dia)
32 mm nominal bore.
40 mm nominal bore
50 mm nominal bore
50 mm nominal bore
litre
Cutting holes upto 15x15 cm in R.C.C. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including finishing complete so as to make it leak proof.
meter
meter
meter
150 mm diameter S.W. pipe
Providing and fixing square-mouth S.W. gully trap grade 'A'’ complete with C.I. grating brick masonry chamber with well burnt modular clay bricks crushing strength not less than 35kg/ cm², water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design : 20.3.1 - 100x100 mm size P type
Constructing brick masonry manhole with well burnt modular clay bricks crushing strength not less than 35kg/ cm² in cement mortar 1:4 ( 1 cement : 4 coarse sand), R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation in cement concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement complete as per standard design : 20.7.1-Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) :
Extra for depth for manholes 20.8.1 - Size 90x80 cm
meter
Providing and constructing soak pit 1.20x1.20x1.20m filled with brickbats including S.W. drain pipe 100 mm diameter and 1.20 m long complete as per standard design.
Construction of RCC Drain/Cover/Chamber (ii) Construction of RCC drain/chamber cover, placing in position, providing shuttering and concreting by using concrete mixer, compaction by vibration etc complete as per drawings and technical specifications excluding reinforcement. with RCC M-20
Supplying, Fitting and Placing un-coated HYSD bar Reinforcement in drain/cover/chamber complete as per Drawing and Technical Specifications.
Wall painting with acrylic premium emulsion (plastic) paint of required shade to give an even shade. 14.10.1 On new work (two or more coats)
On new work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm)
Wiring for light/ fan/ exhaust fan / call bell point with 3x1.5 sqmm FRLS PVC insulated stranded copper conductor wire for phase, neutral and earth in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) with 5/6 amp modular switch, modular base and cover plate, suitable size G.I. box as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) 1.7.1 Short Point
Medium Point
Long Point
Wiring for twin control light point with 3x1.5 sqmm FRLS PVC insulated stranded copper conductor wire for phase, neutral and earth in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) with 5/6 amp modular switch, modular base and cover plate, suitable size G.I. box as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5)
Extra for providing and fixing light plug point on board in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) point wiring with modular type 3 pin 5/6 amp socket outlet and 5/6 amp switch including cost of base and cover plate and G. I. box etc. as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5)
Wiring for light plug point with 3x2.5 sq mm FRLS PVC insulated stranded copper conductor wire for phase, neutral and earth in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) along with modular type 6 Amp switch and 3 pin 6 amps socket outlet with modular base and cover plate, suitable size G.I. box, earthing the switch box and socket outlet with same size wire etc. as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) 1.10.1 Short Point
Medium Point
Long Point
Extra Long Point I
Extra Long Point II
Extra Long Point III
Wiring for power plug point with 3x4 sq mm FRLS PVC insulated stranded copper conductor wire for phase, neutral and earth in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) along with modular type 16 Amp switch and 6 pin 16 amps socket outlet with modular base and cover plate, suitable size G.I. box, earthing the switch box and socket outlet with same size wire etc. as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) 1.11.1 Short Point
Medium Point
Long Point
Extra Long Point I
Extra Long Point II
Extra Long Point III
Wiring for circuit/ sub main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, wire in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) 1.13.1 3 X 1.5 sq. mm in 20mm conduit
3 X 2.5 sq. mm in 20mm conduit
6 X 2.5 sq. mm in 25mm conduit
9 X 2.5 sq. mm in 32mm conduit
12 X 2.5 sq. mm in 32mm conduit
3 X 4 sq. mm in 25mm conduit
Supplying and fixing of following sizes FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) along with accessories in concealed complete as per specification and IS: 9537 (2000 Part 5) 1.15.1 20 mm
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, multi strand wire in the existing surface/ concealed, FRLS PVC conduit / PVC casing caping as per specification and IS: 694 (2010) 3.11.35 5 x 10 sq. mm
Supplying and drawing following grade co-axial TV wire FRLS PVC insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ concealed Steel/PVC conduit as per specification and IS: 694 (2010) 3.13.2 RG-11 grade
Supplying and drawing UTP 4 pair Cat 6 LAN wire in existing surface/ concealed Steel/FRLS PVC conduit as per specification and IS: 694 (2010)
RJ-45 {CAT6} socket outlet
RJ-45 {CAT6} LAN, I/O Box
T.V. antenna socket outlet
Batten/ angle holder
Blanking plate
Providing and fixing fan hook made of 12mm dia steel bar in existing ceiling slab including cutting of roof, fixing hook above reinforcement on both side, repairing with cement mortar 1:2 (1 cement : 2 sand) etc. as per specification.
1400 mm sweep
Supplying, installation, testing and commissioning of following sizes heavy duty (continuous running) 1400 rpm exhaust fan in existing opening in wall including earthing etc. complete as per specification. P.F. should be greater than 0.9 6.6.1 300 mm sweep
Supplying, installation, testing and commissioning of following sizes fancy exhaust fan having built in louvers in existing opening in wall including earthing etc. complete as per specification. P.F. should be greater than 0.9 6.8.2 300 mm sweep
Supplying, installation, testing and commissioning of following LED tube light fitting including batten with Electronic Driver Heat sink Capacitor complete with all other accessories on surface/ in false ceiling, including connection, earthing etc complete as per specification and IP20, P.F. should be greater than 0.9. LED chip efficacy ratio ≥ 100 lumens /watt. 6.19.3 18/20 watt {4 feet}
25x5mm (200 amps)
40x5mm (300 amps)
Fabrication, supply, installation, testing and commissioning of cubicle type compartmentalized wall/ floor mounted power cum control panel board of specified size and following depth made out of not less than 2 mm thick CRCA MS powder coated sheet with suitable size compartments for bus bars, switchgears and necessary cutouts for voltmeters, ammeters etc as per specifications including powder coating painting but without busbars, switchgears and other accessories etc complete as per specification. 7.19.1 Upto 300 mm deep
Supply, installation, testing and commissioning of 4 pole (3 phase + neutral) aluminium bus bars in existing cubicle type compartmentalized wall/ floor mounted panel board along with suitable size and shape insulators, necessary bolts and nuts etc complete as per specification. 7.20.1 100 amp (20x5mm)
200 amp (30x5mm)
300 amp (50x5mm)
3 pole MCCB, 100A, Adjustable Thermal - Magnetic Release,25KA
3 pole MCCB, 125A, Adjustable Thermal - Magnetic Release,25KA
3 pole MCCB, 250A, Adjustable Thermal - Magnetic Release,35KA
6 way Double door
Supplying and fixing SP MCB, 240 volts, 'C' curve, suitable for inductive load in the existing MCB DB complete with connections, testing and commissioning etc. as per specification. 9.11.2 6 amps to 32 amps
Supplying and fixing DP MCB, 240 volts, 'C' curve, suitable for lighting and other loads in the existing MCB DB complete with connections, testing and commissioning etc. as per specification. 9.12.3 40 amps
Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as per specification.
Supplying and fixing sheet steel enclosure of suitable size made of 1.6mm thick CRCA MS sheet, for 100 amps MCCB on existing metal board/ wall including painting etc as per specification.
Providing and fixing panel mounting digital type VAF (Volt-amp-frequency combined) meter of size 100x100 (NS) in existing cubical panel including connection, testing and commissioning etc. as per specification.
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe, with charcoal and salt as per specification and IS Code 3043: 1987(R 2016)
Supplying and laying 8 SWG copper wire at 0.50 metre below ground level for conductor earth electrode, including soldering etc. as per specification.
Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including soldering, excavation and refilling the trench etc. as per specification.
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ concealed conduit/ submain wiring/ cable as per specification.
Providing maintenance free earthing with following size GI pipe including making bore pit of minimum 150mm dia, providing and laying approved make Earthing Electrode of Pipe-in-Pipe technology as per IS 3043(R 2016) -1987 made of corrosion free G.I. Pipes having outer pipe of 80mm dia and inner pipe of 50mm dia and filling with specified qty highly conductive compound around pipe and above that with soft soil in bore pit complete and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. as per specification: 12.19.1 With 3 metre long GI Pipes and 50 kg back filling compound.
meter
Supplying and laying following sizes one number FRLS PVC insulated/XLPE, PVC sheathed, steel armoured, aluminium conductor power cable of 1.1 KV grade direct in ground at a depth not less than 40 cm and upto 90 cm including excavtion, sand cushioning, protective covering and refilling the trench etc as per specification, IS: 1554 (1988, Part 1) & IS: 7098 (1988, Part 1). 15.1.16 3.5 x 120 sq. mm.
meter
meter
Supplying and making end termination with brass compression gland and aluminum lugs for following size armoured aluminum conductor power cable of 1.1 KV grade as per specification. 15.23.17 3½ X 120 sq. mm (45 mm)
Fire alarm Control panel (UL Listed) suitable for 50 addressable points (Detector & Devices). Comprising of the following system components: Operating units, Periphery boards, Power supplies,System enclosures, with battery backup 24hours and 30minutes,
Intelligent Addressable Type Manual Call Point: Intelligent Manual Fire Alarm Box is constructed of durable, molded and polycarbonate material that is matte finished in red with raised white lettering Single-action,Pull-down lever is down, until manually reset,Polarity insensitive via SureWireTM technology
Short circuit Isolator Base: Local light-emitting diode (LED) indicator UL 864 9th Edition Listed and ULC Listed; FM Approved
2 core x 1.5 sq.mm Armoured FRLS cable
Supply and erecting following ISI marked Fire extenguishers on wall/ column including erecting bracket etc complete. 26.17.2 ABC Fire Extinguisher 6KG Nitrogen Store Pressure As per IS: 15683:2018 Body Sheet Not Less Then 2mm Thickness, CE Mark NRV Valve With ABC Powder 90% UL 299 FIRE RATING: 4A, 144B. With all accessories.
ABC Fire Extinguisher 4KG Nitrogen Store Pressure As per IS: 15683:2018 Body Sheet Not Less Then 2mm Thickness, CE Mark NRV Valve With ABC Powder 90% UL 299 FIRE RATING: 2A, 89B. With all accessories.
CO2 type Fire Extinguisher ISI marked confirming to IS:15683:2018 Capacity 4.5Kg. INITIAL CHARGE:- Carbon dioxide used in extinguishers shall comply with IS 15222. FIRE RATING:- 55B. Complete with Hose Assembly and horn , locking arrangement, operation manual, bracket with two screw and sleeve
Supplying , installation , testing and commissioning of 4MP Bullet camera Weather & dust Proof IP based fixed lens day/night camera (IP67 IP 10) 1/3'' 4MP PS CMOS image sensor , H.265 and H.264 triple-stream encoding, WDR (120db), day/night support, UL, CE FCC Certified as per the Specification.
Supplying , installation , testing and commissioning of 2MP DOME camera Weather & dust Proof IP based fixed lens day/night camera (IP66) 2 Megapixel CMOS image sensor , H.265 and H.264 triple-stream encoding, WDR (120db), day/night support, UL, CE FCC Certified as per the Specification.
Supplying , installation , testing and commissioning of 32 Channel NVR 8 Sata Port - Up to 32 channel IP camera input , Max 320Mbps incoming bandwidth , Smart H.265+/H.265/Smart H.264+/H.264/MJPEG , Up to 12MP resolution preview and playback , Support 8 SATA HDDs up to 10TB each,1 eSata , 4 USB(2 USB3.0, 2USB2.0) , 2 HDMI / 2 VGA simultaneous video output ,ONVIF Version 2.4 conformance , Alarm In / out 16/6 , Two way talk 1 Channel Input, 2 Channel Output RCA , 1 RS485, 1 RS232 , 2 RJ-45 port (10/100/1000Mbps), Support ANPR Camera as per the Specification.
Supplying , installation , testing and commissioning of 16 Port Giga PoE switch 10/100/1000 16 Port with 2 Giga SFP uplink, PoE switch Power Budget 150 watt ,Single Port Max 30W , AI Extend ,AI VLAN as per the Specification.
Supplying , installation , testing and commissioning of 2 TB Surveillance HDD complete as required.
Supplying , installation , testing and commissioning of 16 Port Non PoE Giga Byte Switch- 10/100/1000 16 Port Gigabit Network Switch as per the Specification.
Supplying , installation , testing and commissioning of 9U Indoor Rack Wallmount 9U 630D With Front Glass Door Lock & Key 550 9U - (with 1U cable Manager;Fan;6 socket PDU) complete as required.
Supplying, installation, testing and commissioing of following size LED Monitor, table/wall mount with inbuild speaker minimum 5Wx2,with minimum 1 No of HDMI and USB port including remote control, connecting cable, batteries, and all accessories, connection etc complete as per specification. 27.49.2 43 inch
UOM Name
Percentage
Per mile
Siemens Per meter
Activity unit
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 1.07 MB
2901156594268322202_183747_Form A.doc
NIT • 0.15 MB
3662590503382863201_153213_1258250143523725404_129113_Guidelines_to_Bidders_EPS_v1.pdf
NIT • 0.13 MB
4573875830083443934_183747_ANNEXURE-E.doc
NIT • 0.08 MB
6400807594917203494_183747_NIT.doc
NIT • 0.35 MB
8821097056554481143_183747_LIST OF APPROVED MATERIAL.doc
NIT • 0.06 MB
793356254182602631_186320_Notice.docx
NIT • 0.04 MB
3052607276565469431_183747_BOQ.xls
BOQ • 0.19 MB
Download all tender documents and submit your bid