Tender Value
₹85.2 L
EMD Value
₹1.5 L
Closing Date
7 Apr 2025, 6:00 pmClosed
CE Bhopal Zone
HQ Chief Engineer Bhopal Zone SI Lines Bhopal PIN - 462001
COMPLETION OF INCOMPLETE WORKS FOR PROVN OF OTM ACCN FOR MDC AT GWALIOR
2025_MES_698445_1
CEBZ/GWL/TOKEN/22 OF 2024-25
Open Tender
Civil Works
Lump-sum
110 days
Gwalior
As per tender documents
4 documents required · 4 mandatory
₹1,000
GE Gwalior
₹1.5 L
Bhopal
30 Jun 2025
18 Feb 2025
9 Apr 2025
18 Feb 2025
7 Apr 2025
24 Mar 2025
4 Mar 2025
Amount
Note: (i) Please refer schedule 'A' notes before quoting the tender. (ii) Amount of Schedule of credit shall be deducted off line by the department.
GENERAL SUMMARY
Lump sum price worked out by the contractor for Building works as listed in Schedule ‘A’ Part- I ( Ref prepriced schedule attached seperately)
Lump sum price worked out by the contractor for INTERNAL WATER SUPPLY as listed in Schedule ‘A’ Part- II ( Ref prepriced schedule attached seperately)
Lump sum price worked out by the contractor for INTERNAL ELECTRIFICATION as listed in Schedule ‘A’ Part- III ( Ref prepriced schedule attached seperately)
Lump sum price worked out by the contractor for EXTERNAL WATER SUPPLY as listed in Schedule ‘A’ Part- IV ( Ref prepriced schedule attached seperately)
Lump sum price worked out by the contractor for EXTERNAL ELETRIC SUPPLY as listed in Schedule ‘A’ Part- V ( Ref prepriced schedule attached seperately)
Lump sum price worked out by the contractor for ROAD, PATH & CULVERT as listed in Schedule ‘A’ Part- VI ( Ref prepriced schedule attached seperately)
Lump sum price worked out by the contractor for COMPOUND WALL,SECURITY FENCING & GATE as listed in Schedule ‘A’ Part- VII ( Ref prepriced schedule attached seperately)
Lump sum price worked out by the contractor for AREA DRAINAGE as listed in Schedule ‘A’ Part- VIII ( Ref prepriced schedule attached seperately)
Lump sum price worked out by the contractor for FIRE ALARM & FIRE DETECTION SYSTEM as listed in Schedule ‘A’ Part- IX ( Ref prepriced schedule attached seperately)
Lump sum price worked out by the contractor for HOT WATER SUPPLY as listed in Schedule ‘A’ Part- X ( Ref prepriced schedule attached seperately)
Lump sum price worked out by the contractor for SEWAGE DISPOSAL as listed in Schedule ‘A’ Part- XI ( Ref prepriced schedule attached seperately)
Lump sum price worked out by the contractor for EXACAVATION, EARTH WORK & SITE DEVELOPMENT as listed in Schedule ‘A’ Part- XII ( Ref prepriced schedule attached seperately)
PRIME COST SUM Provide Prime cost sum for designing, supply and fixing structural glazing for Sch "A" Part I item no 1 for the locations shown on drgs complete . (i) Add/deduct__________% (Contractor to quote lumpsum amount in column 6 which will be converted to percentage over /below) Amount quoted by the contractor shall not exceed 15% above the amount incerted in col 5. However contractor may quote lower amount than inserted in col 5 . If contractor quotes amount more than 15% then it will be reduced/ revised to 15% only.
Sch'A' Part-XIII (Miscellaneous)
INTERNAL WATER SUPPLY
S&F, bib tap,fancy type, long nose ,cast copper alloy (ISI Marked), chromium plated with crutch or butter fly handle, screwed down and screwed for iron pipe 15 mm dia as specified and directed.
S&F angle valve, cast copper alloy, fancy type, chromium plated 15 mm bore, screwed down, high pressure, screwed both end for iron pipe or for union all as specified and directed.
INTERNAL ELETRIFICATION NOTE:- For items of internal Electrifications notes given at the beginning of Sch ‘A’ Part-III (internal Electrification) shall also be applicable.
M & L for Point wiring using approved colour coding as per IS (Red, Black and Green for single phase circuits), with multi-stranded copper conductor 1.5 Sq. mm nominal cross-sectional area, single core, PVC insulated and unsheathed FRLS cable 1100 volts grade, ISI-694 marked with valid CML No., drawn in and including medium grade, rigid PVC concealed conduit and conduit accessories concealed in wall/roof/floor etc, ISI marked with valid CML No.(IS-9537-1983 for conduits and IS:3419:1976 for conduit accessories), in mild steel/pressed steel sunken boxes (with earth dolly) with 3mm thick phenolic laminated hylam sheet cover for fixing of switches, sockets and fan regulators etc, including PVC insulated multi-stranded copper conductor 1.5 Sq mm nominal cross sectional area single core FRLS cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed at site for the fwg:-
One light point controlled by one 5/6 amps one way switch
One fan point controlled by one 5/6 amps one way switch .
M & L for Point wiring using approved colour coding as per IS (Red, Black and Green for single phase circuits), with multi-stranded copper conductor 1.5 Sq. mm nominal cross-sectional area, single core, PVC insulated and unsheathed FRLS cable 1100 volts grade, ISI-694 marked with valid CML No., drawn in existing medium grade, rigid PVC concealed conduit and conduit accessories concealed in wall/roof/floor etc, ISI marked with valid CML No.(IS-9537-1983 for conduits and IS:3419:1976 for conduit accessories), & in existing mild steel/pressed steel sunken boxes (with earth dolly). Also, M&L for provision of 3mm thick phenolic laminated hylam sheet cover for fixing of switches, sockets and fan regulators etc, including PVC insulated multi-stranded copper conductor 1.5 Sq mm nominal cross sectional area single core FRLS cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed at site for the fwg:-
One light point controlled by one 5/6 amps one way switch
One fan point controlled by one 5/6 amps one way switch .
One Socket outlet, three/five pin, 5 Amp, controlled by by one 5/6 amps one way switch or switch/socket combination 5 amps, 5 pin. on independent board
One Socket outlet, three/five pin, 5 Amp, controlled by by one 5/6 amps one way switch or switch/socket combination 5 amps, 5 pin. on the same board with other switches,sockets, fan regulators etc.
One exhaust fan point controlled by one 5/6 amp switch.
One Bell/Buzzer points controlled by one 5/6 Amps bell push.
M & L for Point wiring using approved colour coding as per IS (Red, Black and Green for single phase circuits), with multi-stranded copper FRLS conductor 2.5 Sq. mm nominal cross-sectional area, single core, PVC insulated and unsheathed cable 1100 volts grade, ISI-694 marked with valid CML No., drawn in and including medium grade, PVC concealed conduit and conduit accessories concealed in wall/roof/floor etc, ISI marked with valid CML No.(IS-9537-1983 for conduits and IS:3419:1976 for conduit accessories), in mild steel/pressed steel sunken boxes (with earth dolly) with 3mm thick phenolic laminated hylam sheet cover for fixing of switches and sockets etc, including PVC insulated multi-stranded copper conductor 2.5 Sq mm nominal cross sectional area single core cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed at site for the one 3/5 pin amps 15/16 Amp socket outlet independent:
M & L for Point wiring using approved colour coding as per IS (Red, Black and Green for single phase circuits), with multi-stranded copper FRLS conductor 2.5 Sq. mm nominal cross-sectional area, single core, PVC insulated and unsheathed cable 1100 volts grade, ISI-694 marked with valid CML No., drawn in existing medium grade, PVC concealed conduit and conduit accessories concealed in wall/roof/floor etc, ISI marked with valid CML No.(IS-9537-1983 for conduits and IS:3419:1976 for conduit accessories), and in existing mild steel/pressed steel sunken boxes (with earth dolly). Also, M&L for provision of 3mm thick phenolic laminated hylam sheet cover for fixing of switches and sockets etc, including PVC insulated multi-stranded copper conductor 2.5 Sq mm nominal cross sectional area single core cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed at site for the one 3/5 pin amps 15/16 Amp socket outlet independent:
M & L for point wiring using approved colour coding as per IS (Red, Black and Green for single phase circuits), with multi-stranded copper FRLS conductor 4.0 Sq. mm nominal cross-sectional area, single core, PVC insulated and unsheathed cable 1100 volts grade, ISI-694 marked with valid CML No. drawn in and including medium grade, PVC concealed conduit and conduit accessories concealed in wall/roof/floor etc, ISI marked with valid CML No.(IS-9537-1983 for conduits and IS:3419:1976 for conduit accessories), in mild steel/pressed steel sunken boxes (with earth dolly) with 3mm thick phenolic laminated hylam sheet cover for fixing of switches and sockets etc , including PVC insulated multi-stranded copper conductor 4.0 Sq mm nominal cross sectional area single core cable as earth continuity conductor to common earth and connecting to earth dolly complee all as specified and directed at site for the one 3/5 pin 15/16 amps socket outlet independent: (NOTE: Sheat Metal enclosure with switch & sockets will be measured & paid separetly )
M & L for point wiring using approved colour coding as per IS (Red, Black and Green for single phase circuits), with multi-stranded copper FRLS conductor 4.0 Sq. mm nominal cross-sectional area, single core, PVC insulated and unsheathed cable 1100 volts grade, ISI-694 marked with valid CML No. drawn in existing medium grade, PVC concealed conduit and conduit accessories concealed in wall/roof/floor etc, ISI marked with valid CML No.(IS-9537-1983 for conduits and IS:3419:1976 for conduit accessories), and in existing mild steel/pressed steel sunken boxes (with earth dolly). Also, M&L for provision of 3mm thick phenolic laminated hylam sheet cover for fixing of switches and sockets etc , including PVC insulated multi-stranded copper conductor 4.0 Sq mm nominal cross sectional area single core cable as earth continuity conductor to common earth and connecting to earth dolly complee all as specified and directed at site for the one 3/5 pin 15/16 amps socket outlet independent: (NOTE: Sheat Metal enclosure with switch & sockets will be measured & paid separetly )
Supply, fixing and testing ceiling fan of 1400mm sweep, 230 Volts, single phase, 50 Hz 3 blades, double ball bearing, BE rating connection up complete with and including three core flexible PVC insulated multi stranded copper conductor cable of size 0.5 sqmm from ceiling rose / connector, including extra GI / MS pipe down rode, as per site requirement (approximate length 01 Mtr) complete all as specified and directed.
Supply and fixing telephone socket multipurpose for telephone complete all as specified and directed.
Supply and fixing ceiling fan regulator electronic step type 120 Volts, 100W ISI marked with valid CML No. and connecting up complete
Supply fixing and testing exhaust fan electric single phase AC 240 Volts 50 HZ supply heavy duty corrosion resistant of 300 mm sweep size , 1400RPM , aluminium pressure die cast motor powder coated paint finished , light weight heavy duty , double ball bearing ,with louvers and connecting including provision 3 core flexible PVC insulated multi stranded copper conductor of size 0.5 Sqmm from ceiling rose/connector to fan incl four Nos of nuts,bolts and washers for fixing the frame, guarantee card complete all as specified. Make:- Bajaj / Crompton Greave /Almonard.
Supply fixing and testing plastic exhaust fan / Refresh air -DX electric single phase AC 240 Volts 50 HZ supply corrosion resistant of 250 mm sweep size , 1350 RPM , Air dilvery 520 cfm , light weight and connecting including provision 3 core flexible PVC insulated multi stranded copper conductor of size 0.5 Sqmm from ceiling rose/connector to fan incl four Nos of nuts,bolts and washers for fixing the frame, guarantee card complete all as specified and directed . Make:- Bajaj / Grompton Greave /Almonard.
Supply & Fixing of LED tube light wall / ceiling mounting, minimum capacity of 1 x 22W LED box type tube light with system lumens with system efficacy > 115 Lm /W at System level (including the driver loss) . The Luminaire should have Cool day light color temp of 6500 K CRI> 80. Life 40,000 burning hours with 70% lumen maintenance . PF > 0.95 Surge protection of > 2 KV. All the photometrical and electrical parameters must be supported by LM 79-80 test report from NABL, Accredited Lab OR UL Switching cycle of 50,000 times, lamp starting time is not more than one sec. The LED tube light confirms to applicable IS 10322/EN 60598. Housing of Batten should be made from single piece powder coated CRCA sheet steel.complete all as specified and directed at site Make- Wipro /Bajaj /Philips Notes: 1. Warranty for replacement of each LED shall not be less than 1 year from the date of purchase. 2. Date of Purchase shall be marked on each fixture with permanent marker for redeeming warrenty + benifits.
Supply and fixing 1 X40 W LED Porch light including lamp 40W square shape suitable for 230V Ac , 50 Hz single phase all as directed and specified , Make- Philips, Bajaj, Crompton Greaves, Wipro
Supply & fixing of Recess mounted minimum 15W LED 1'x1' White powder coated CRCA housing with LEDs. Seamless front frame with white coloured flat acrylic cover with electronic drive including testing & commissioning complete all as specified and directed. Make- Philips, Bajaj, Crompton Greaves, Wipro
Supply & fixing of Recess mounted minimum 22W LED 1'x1' White powder coated CRCA housing with and including LEDs. Seamless front frame with white coloured flat acrylic cover with electronic drive including testing & commissioning complete all as specified and directed. completion with complete in all respect. Make- Philips , Bajaj, Crompton Greaves, Wipro
Supply and fixing batton holder including 9W LED lamp , 230 Volt, 50 Hz, Ac all as specified and directed Make- Philips , Bajaj, Crompton Greaves, Wipro
Supply and fixing street light fitting LED fitting minimum capacity 1 X 24W with and including LED 24 W single phase 240 V , 50 Hz , IP 66 powder coated pressure die cast aluminium compact high power with heat resistant toughened glass all fittings/fixtures prewired, gear cum reflector including 25 mm dia galvanised iron pipe light grade bracket bent to shape over all length 1.6 mtr fixed to wall with 2 Nosclamps made of flat iron of size 25 x 6mm and suitable bolts and nuts with washers, including connecting with PVC insulated multi stranded copper flexible cable of size 0.5 Sqm three core from ceiling rose to fitting complete all as specified and directed, Street light fitting Make:-Phillips, Bajaj , wipro .
Supply , installation & commissioning MCB/MCCB Vertical Distribution board TPN double door with Provision 100 Amp MCCB, four Pole as incomer and provision for 12 Nos single phase MCB outgoing factory made, confirming to IS, fabricated out of CRCA sheet, fitted with DIN channel, neutral link and 200 Amp bus bar, DBs shall be semi glossy finished with epoxy polyester based powder paint sprayed and backed at high temperature, between powder paint process the sheet steel having to go through the anti rust conditioning in not less than seven tank process to ensure smooth finish and protection against corrosion atmosphere. The DBs shall be double door type with hinged door with locking arrangement. The DP/SP/TP MCB shall be of same make as DB. DB shall also be provided with label marking indicating the incoming and outgoing circuits on all way as specified. The DBs shall be of IP 43 - IK 09 with metal door complete all as specified and directed . NOTE:- MCCB and MCB will be measured and paid seperately.
Supply and Fixing Distribution board SPN 12 way Double door including connecting of mounting MCBs isolator, ELCBs etc factory made, confirming to IS:13032 fabricated out of CRCA sheet not less than 1.2 mm thick fitted with DIN channel, neutral link and 200 Amps rated bus bar. DBs shall be semi glossy finished with epoxy polyster based powder paint sprayed and backed at high temperature, between powder paint process the sheet steel having to go through the anti rust conditioning in not less than seven tank process to ensure smooth finish and protection against corrosion atmosphere. The DBs shall be single door type with hinged door with locking arrangement. The DBs shall be of same make as MCBs /Isolator. DB shall also be provided with lable marking indicating the incoming and outgoing circuits on all way as specified. The DBs shall be of IP 42 protection class.
All as per item no 3.26 above but DB SPN 4 way
Supply and Fixing MCB , SPN 20 Amp, 240 Volt , breaking capacity 10KA with "B" Charactristic complete all as specified and directed .
Supply and Fixing MCB , SP 40 Amp, 240 Volt single pole, breaking capacity 10KA with "B" Charactristic complete all as specified and directed .
Supply and Fixing MCCB TPN 100A, 415 Volts , breaking capacity 16 KA complete all as specified and directed
Supply and Fixing MCB , SP ( upto 32 Amp) 240 Volt single pole, breaking capacity 10KA with "B" Charactristic complete all as specified and directed
Supply and fixing MCB SPN 63 Amp 240 Volt breaking capacity 10 KA with B characterstic complete all as specified and directed.
Supply and fixing MCB SP 63 Amp 240 Volt breaking capacity 10 KA with B characterstic complete all as specified and directed.
Supply and fixing MCB SPN 32 Amp 240 Volt breaking capacity 10 KA with B characterstic complete all as specified and directed.
Sub main wiring with approved colour coding as per IS (Red, Black and Green for single phase circuits) with two single core PVC insulated cable with stranded copper conductor of nominal cross section area as under and drawing into existing PVC non metallic rigid conduit suitable dia including PVC insulated stranded copper conductor nominal cross section area as under as contineous earth continuity wire complete all as specified for item No 5.37 to 5.38:- Note :- Two runs of current carrying conductor and one run of earth conductor and one run of conduit shall be measured as unit length.
(a) Two runs of 6 Sq mm as current carrying conductor and one run of 6 Sq mm as earth conductor.
(b) Two runs of 4 Sq mm as current carrying conductor and one run of 4 Sq mm as earth conductor.
Sub main wiring with approved colour coding as per IS (Red, Black and Green for single phase circuits) with two single core PVC insulated cable with stranded copper conductor of nominal cross section area as under and drawing into and including PVC non metallic rigid conduit suitable dia including PVC insulated stranded copper conductor nominal cross section area as under as contineous earth continuity wire complete all as specified item No 5.40 to 5.42:- Note :- Two runs of current carrying conductor and one run of earth conductor and one run of conduit shall be measured as unit length.
(a) Two runs of 16 Sq mm as current carrying conductor and one run of 16 Sq mm as earth conductor
(b) Two runs of 6 Sq mm as current carrying conductor and one run of 6 Sq mm as earth conductor.
(c) Two runs of 4 Sq mm as current carrying conductor and one run of 4 Sq mm as earth conductor.
Supply and fixing PVC rigid conduit medium grade suitable for telephone wiring concealed on wall floor ceiling etc of size 20mm including all fitting like bend elbow socket reducers etc all as specified and directed
M & L for Earthing complete with galvanized steel earth plate electrode 600 x 600 x 6 mm thick buried directly in ground (earth pit not less than 2.25 metre deep below ground level) with top edge of plate not less than 1.5 metre below normal ground level connected to galvanized earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical Plate No 3 of MES SSR-2009 Part-I connected to main switch board or main control board all as specified and testing on completion including provision of earth wire protected by 15mm dia light grade GI pipe and watering pipe shall be 20mm bore light grade including all excavation and earth work in any type of soil, PCC pit with pre-cast RCC cover with handle of 8 mm dia bar, charcoal/salt, funnel with wire mesh etc complete all as directed. NOTE :- (i) The concrete pit shall be PCC (1:3:6) type C-1, 40 mm thick pre cast cover slab of RCC (1:2:4) type B-1 using 20mm graded stone aggregate reinforced with 8mm TMT bars @ 10 cm C/C on both sides with suitable cast iron handle shall be provided in lieu of cast iron cover shown in electrical plate No 3 of MES SSR Part-I. (ii) The unit rate includes the cost of GI pipe light grade for protection of earth wire and 4mm dia earh lead wire upto 7.5 M. (iii) PCC pit shall be provided at least 500 mm away from the pit and not on the earth pit itself. (NOTE- 04 nos Eathing for Internal Electification and 02 nos for External Electrification)
Supply & Fixing PVC junction boxes suitable for (1 to 4 way ) for PVC conduits of 20mm complete all as specified and directed.
EXTERNAL WATER SUPPLY--
Material and labour for contruction of valve pit Brick/stone/PCC block masonary constructed of size 900 x 900x 900mm (Internal dimensions) complete with mild steel sheet cover 3mm thick and angle iron frame of size 50x 50x 6mm , heavy duty fabricated hinges duly painted with two coats of synthetic enemal paint over a coat of red oxide primer and including locking arrangement and lifting handle including plastering in 1:4 cement mortar, 15mm thick, complete all as specified including excavation and earth work in any type of strata, plastering all walls surfaces internally and flush pointing to brick work externally competely all as specified and as directed.
EXTERNAL ELETRIFICATION -
Supply & fixing LED street light fitting pressure dia cast aluminum housing IP-66 with all accessoreis of minimum 45 Watt 240 Volt, 50 Hz complete with and including connection from junction box to fitting connecter with suitable multistranded copper conductor cable of 2.5 Sqmm 3 core complete all as specified and as directed.NOTE-Cost of LEDs included in unit rate quoted.
Supply and fixing 40 mm bore or next suitable size ( for LED fittings) light grade GI bracket 1.20 mtr long bent to shape by cutting welding and well finishing including MS clamp of flat iron of size 40x6mm suitable length 2 nos complete for steel tubular poles with nuts bolts and painting with two coats of aluminium paint over a coat of primer on MS clamp complete all as specified & directed.
S & F street light Engineering plastic one piece moulding control box (size 350x250x150mm) with locking arrangment made out of HDPE and FI clamp 25 x 3 mm complete including MCB SP 6 Amp 240 Volts complete with 04 Nos aluminum busbar of rating 63 amps for phase and neutral on porcelain based insulators and fixing clamps to pole for street lights, all as required and directed at site.Make- Sintex/ Hensel/ Eqv.
M & L for Boring of holes under road/railway crossing, pavement, hardstanding by trenchless technology using ultra sound technique and necessary machine suitable for and including HDPE pipe of 150mm dia suitable for 0.4mpa working pressure complete all as specified and directed.
S & F intelligent outdoor street light control for single phase load of capacity of 1 KW including MCB,power contactor and SMC enclosure complete all as specified and directed.
Supply and fixing for LT cable route indicator , 6mm thick CI plate of size 100mm dia welded to MS angle iron 50x50x6 mm embeded in PCC 1:3:6 type C-1 block size 150x150x160 mm and painted with brown colour complete all as specified and as directed.
M&L for earthing complete with galvanized steel earth plate electrode of size 60cm X 60 cm X 6 mm buried directly in ground (earth pit not less than 2.25m deep below the normal ground level) with top edge of plate not less than 1.5 m below the normal ground level connected to GI earth strip 32 X 6 mm dia as earth lead by means of bolts, nuts, check nuts and washers of galvanized iron or steel, protected by GI pipe light grade 40mm bore all as shown on electrical plate No 3 of SSR Part-I connected to earth test point electrode, PCC pit with RCC cover, funnel with wire mesh, watering pipe 20mm dia protection pipe etc and testing on completion complete all as specified and directed. Note No 1 :- The unit rate shall also include for earth work in hard/dense soil, PCC (1:3:6) type C1 chamber, RCC 1:2:4 type B-1 cover 50 mm thick reinforced with 8 mm dia TMT bar @ 150 mm c/c both ways, funnel with watering pipe 20 mm dia medium grade, GI protection pipe light grade 40 mm dia and wire mesh complete in addition to item No 1 (a) to (e) of preamble (Notes) under sub-heading earthing, specified on Serial Page No 389 of SSR Part –I. Note No 2 :- Earthing strip and GI protection pipe beyond 7.5 m will be measured and paid separately if required (iii) PCC pit shall be provided at least 500 mm away from the pit and not on the earth pit itself.
FIRE ALARM & DETECTION SYSTEM ---
Supply and fixed concealed rigid non metallic PVC conduit 25mm external dia inclusive of boxes (junction terminals) , all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, locks, nuts, saddles, pipe hooks suitable for 25 mm external dia of pipe complete all as specified and directed
M & L for providing 3 zone fire repecated panel (adressable type) with suitable battery backup provision to be mounted on wall for zone status of main fire alarm panel all as complete all as specified and directed
M & L for Fire alarm control panel complying with BS EN 54 three loop panel of capacity from 99 to detectors and 99 modules upto 300 detector and modules (99 each per loop) panel should have additional provision for local fire alarm inside the panel ( i.e. it should give audio alarm in case of fire) complete all as specified and as directed.
M & L for cabling for fire detection and alarm sys with 2 core enamelled tinned copper conductor PVC sheathed, flexible, 4 X 1.5 Sqmm armoured cable as per specification complete all as specified and directed.
M & L for 8 Core 1.5 Sqmm wire from main fire alarm panel to repeater panel ( 1 pair for power supply, 3 pairs for 3 zones and 1 pair for extra) complete all as specified and as directed.
M & L for 2 core 1.5 Sqmm sheathed cable running with PVC conduit all as specified and directed.
M & L for installing at the top of bldg code conductor (IP-65) protection adressable sired siren with fully supervisied power 66 DB pizzo siren high power and it is to be connected/ interfaced with the fire alarm control panel (for its automatic operation in case of fire detection ) complete all as specified and as directed.
HOT WATER SUPPLY ---
Supply, Installation, testing and commisioning of water heater storage type metallic outer body and Copper inner container of 25 Ltrs capacity, electric suitable for single phase, 50Hz, AC supply,5 star rating, including all necessary fittings and fixtures with 2.5 sqmm multistranded 3 core copper conductor cable PVC sheathed of suitable length,PVC connection with brass couplingwashers etc uo to 450 mm dia long suitable for 15 mm dia PVC pipe as required on site with three pin plug top complete all as specified and directed.
(c) Insulated stainless steel Hot water storage tank non pressure type made of stainless steel grade 04 Cr 18 NI or 07 Cr 18 NI of IS 1570 (Part-3)-1985, TIG tank welded of 100 ltrs capacity non magnetic tank with stainless steel fitting with following specification -01 No Shall be insulated with 40mm thermal grade PU insulation FRP cladding, tank stand assembly shall be made of angle of size 38x38x4 mm duly pretreated and stove enammeled with black colour paint. (d) Provision of electric back up minimum 2 KW heating element including providing all necessary items like 1 x 16 Amp MCB SP 10 KA rupturing capacity fixed in enclosure and sub-main wiring in and including concealed conduit with 4 sqmm single core stranded copper conductor conductor, PVC insulated wire from outlet of MCB to electric back up with connected acessories- 01 Job. The solar water heater system shall be provided on roof of single/double story building, the electric back up connection shall be tapped from sub main board provided at ground floor (e) Heat exchanger shall be cage type and make of stainless steel tube of grade for Cr 18 NI of IS 1570 (part-V)-1885 (f) All other pipe/ civil work, steel staging work with min 50 x 50 x 6mm angle iron frame and 6mm thick MS sheet base for PVC tank ,including rotational moulded PVC water storage tank of 500 ltr capacity each including guarding against wind pressure, electrical work outlet and inlet thermometer, air release valve, chek valve gate valve, control and instrument etc of as required shall be deemed to be including in unit rate quoted. System internal piping shall be ISI marked PP-R pipe SDR 7.4 &SDR 11 UV stabilized and antimicrobial duly insulated with 50mm thick of rock wool of 48 Kg/Cum density and 26 SWG aluminium cladding. Note :- (i) The system shall be tested on completion to ensure that 100 (as specified) liters of water at 60 degree centigrade is available in hot water tank on a normal. Normal water pipes and accessories from the normal water over head tank to inlet of plate collector shall be deemed to be included in the cost. similarly hot water pipes from hot water storage tank to bathroom/kitchen shall be deemed to be included in the cost.
Supply, install, connecting and testing of water cooler fully stainless steel non- corrosive electric driven (single phase) having approx storage capacity 150 Ltrs self contained drinking water cooler with (Non - CFC refrigerent) energy efficient compressor and nominal cooling capacity of 140 Ltrs/Hrs including connecting of incoming and outgoing GI pipe medium grade and gate valve of suitable size with necessary PVC Nylone braided pipe, PCC platform including drainig water provision etc. complete all as specified and directed.
Supply & install refrigerator ,electric driven (single phase), 230 Volts, single phase, 50 HZ ,BEE certified minimum 5 star rating) capacity 195 Litres frost free complete .
Supply, installation and testing of commercial evaporative type Air cooler (Desert Cooler) Plastic body, 230 Volts, single phase, having capacity of 4000 cum/hr (450 mm Sweep) Water storage capacity not less than 40 Ltrs, 15 mm dia floot valve and suitable PVC connectors, moquesto proofing net for all sides including fixing arrangements with suitable size of MS angle iron stand with wheel arrangments complete .
Supply & install voltage stabiliser for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170V to 250V with output voltage stabilized at 230V with accuracy of + or - 2.5% for 2 KVA capacity complete all as specified and directed.
Supply & install voltage stabiliser for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170V to 250V with output voltage stabilized at 230V with accuracy of + or - 2.5% for 5 KVA capacity complete all as specified and directed.
Supply, install,testing and commissioning of 5 Star rated air cooled spilt type airconditioners electric driven( 250 Volts, single phase, 50 HZ supply) with Energy efficient Rotary Compressor, working on R-134 or superior enviornment-friendly refrigerant, cordless remote operated, comprising of indoor unit,wall mounted, material of construction of indoor unit ABS, Nominal cooling capacity 6000 KCal/Hr, Minimum Power consumption , Minimum room discharge airflow 700 CuM /Hr Guranteed cooling capacity(Min) 4275 KCal/Hr, outdoor unit, Material of Cabinet GI Sheet 1.0 mm thick powder coated,Copper tubing, electric connection (Between indoor and outdoor unit located upto a maximum distance of 10 Meters) and condensate water drainage arrangement etc complete of capacity 2 Ton complete all as specified and directed at site. Note :- The outdoor unit shall be fixed on wall with standard bracket or fixed on roof /floor with proper MS stand. The cost is deemed to be included in the quoted rates.
M&L for RCC hume pipe culvert 450mm bore dia and 5.60 meter long, class NP-2 (single pipe) laid and jointed complete with collar with PCC (1:4:8) type D-2 in foundation including excavation and earth work in any type of soil and disposal of surplus soil at a distance not exceeding 50 meter, encasing, bedding and hunching of hume pipe in PCC (1:3:6) type C- 1, stone masonry 380 mm thick in CM (1:6) for parapet wall, PCC (1:2:4) type B-1 as in coping, 15mm thick plaster in CM (1:6) on walls including three coats of white wash on plastered surface complete all as shown on drawing No CEBZ/TD/119/2011 Sheet 1/1 and as specified.
Construction of balance portion of Septic tank including excavation, in any type of soil, foundation In PCC 1:2:4 type B-2, brick work in CM 1:4, RCC M25 (with and including reinforcement), Slab covers including RCC precast manhole cover having 6mm plate embedded all around/fibre reinforced cover with angle iron frame Vent pipe shaft and sludge chambers etc., complete for 200 users all as specified and shown in drawing No. CEBZ/TD/77/2011 Sheet 1/3 & 3/3. Note: The work for above Item No 01 partially executed upto approx 95% by previous contractor shall be handed over to the contractor on “as is where is” basis. It shall be the responsibility of the contractor to complete the balance work as per drawings, specification and other conditions of CA including rectification of defects if any left out by previous contractor in such a manner that the finally completed works are structurally sound. However, before quoting the tender, tenderers are requested to visit the site of work and actually workout the quantities of left over works for full and entire completion of the work including minor extra as required to execute the work in a workmanship like manner.
Construction of balance portion of Soakage wells including excavation in any type of soil, foundation in PCC 1:3:6, wells of honey combed and solid in M-25 Concrete type C2, including intercepting chamber, screen chamber Brick work in CM, RCC cover slab in M-25/ RR masonry/ filling with brick bats, complete of size 3m in dia and 6.00m in deep (effective depth) all as specified and shown in drawing No.CEBZ/TD/78/2011 Sheet 1/2 & 2/2. Note: The work partially executed upto approx 80% by previous contractor shall be handed over to the contractor on “as is where is” basis. It shall be the responsibility of the contractor to complete the balance work as per drawings, specification and other conditions of CA including rectification of defects if any left out by previous contractor in such a manner that the finally completed works are structurally sound. However, before quoting the tender, tenderers are requested to visit the site of work and actually workout the quantities of left over works for full and entire completion of the work including minor extra as required to execute the work in a workmanship like manner.
Schedule of credit ( to be deducted offline by the department) (-) 5,45,742.56
M/s Kohli Builders (BID ID -3277354)
Raja enterprises (BID ID -3277025)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .