Loading…
Loading…
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Tender Value
₹24.3 L
EMD Value
₹49,000
Closing Date
22 Oct 2026, 4:00 pm
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Executive Eng. II
Construction office,P.U. Campus
Repair of roofs of other buildings(Other than houses and hostels) of Single story market area, Post office in P.U. Campus, Sector-14, Chandigarh.
2026_PU_95739_1
6913/EE/Mtc.
Open Tender
Civil Works
Percentage
150 days
P.U. Campus, Sector-14
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
₹49,000
25 Sept 2026
25 Sept 2026
23 Oct 2026
25 Sept 2026
22 Oct 2026
25 Sept 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Civil Work | |||||
| 1.01 | Disposal of moorum/building rubbish/ malba/ similar unserviceable, dismantled or waste material by mechanical transport including loading, transporting, unloading to approved municipal dumping ground for lead upto 5km for all lifts, complete as per directions of Engineer-in-charge.(1.1.18) | 62 | Cum | 178 | ₹11,036 |
| 2Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10mm and down gauge) including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design. | |||||
| 2.01 | In 75x75mm deep chase (12.21.1) | 500 | Rmt | 246 | ₹1,23,000 |
| 3 | Making khurras 45x45 cm with average minimum thickness of 5cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1mx1mx400micron, finished with 12mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement rounding the edge sand making and finishing the outlet complete. (12.22) | 15 | no. | 278 | ₹4,170 |
| 4 | Regrading terracing of mud phuska covered with tiles or brick, in cement by dismantling tiles or bricks, removing mud plaster preparing the surface of mud phaska to proper slope relaying mud plaster gobri leaping and tiles or bricks, grouted in cement mortar 1:3 (1 cement : 3 fine sand ) including replacing unserviceable tiles or bricks with new ones and disposal of unserviceable material to the dumping ground (the cost of the new tiles or brick excluded) within 50 metres lead. (14.13) | 1,700 | sqm | 504 | ₹8,56,800 |
| 5Providing and fixing APP (Atactic Polypropylene Polymer) modified prefabricated five layer 3 mm thick water proofing membrance, black finished reinforced with glass fibre matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the same membrance manufacture of density at 25°C, 0.87 - 0.89 kg/ litre and viscocity 70 - 160 cps. Over the primer coat the layer of membrane shall be laid using Butane torch and sealing all joints etc., and preparing the surface complete. The vital physical and chemical parameters of the membrane shall be as under : Joint strength in longitudinal and transverse direction at 23°C as 350/300 N/ 5 cm. Tear strength in longitudinal and transverse direction as 60/80N. Softening point of membrane not less than 150°C. Cold flexibility shall be upto -2°C when tested in accordance with ASTM, D - 5147. The laying of membrane shall be got done through the authorised applicator of the manufacture of membrane. | |||||
| 5.01 | 3mm Thick (14.90.1) | 1,700 | Sqm | 528 | ₹8,97,600 |
| 6 | Removal of old existing water proofing treatment i.e. tarfelt sheet up to 3mm thickness(up to 2 layers), old bitumen layer, loose dust particles, algae, green vegetation by means of steel wire brush/ scrapping paper, existing brick tiles and plaster. After cleaning, minor cracks or holes to be filled with modified polymer mortar mixed with cement as per manufacurer's specification. Complete in all respects to trhe entire satisfaction of the engineer in-charge. ( Ref:- N.S) | 2,000 | Sqm | 50 | ₹1,00,000 |
| 7 | Dismantling old PCC(any Mix) gola, band, haunch,drain etc. and cleaning the surface for making new surface at per site. Complete in all respects to the entire satisfaction of the engineer in-charge.( Ref:- N.S) | 700 | Rmt | 17 | ₹11,900 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 7.31 MB
BOQ_117618.xls
BOQ • 0.34 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .