| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹47.7 LAccepted-AOC STATION ROAD POST RANGIYA DIST KAMRUP ASSAM PIN 781354 | KAMRUP | ASSAM | 781354 | L-1 | Accepted-AOC RATES ARE FOUND REASONABLE AND THE FIRM BEING L1 BIDDER | |
| 2 | L-2₹48.4 L+₹14,698 (0.30%)Rejected-Finance C O SHRI AMRENDER KUMAR YADAV IACHHIPUR SANTOSH NAGAR GORAKHNATH GORAKHPUR UTTAR PRADESH PIN 273015 | GORAKHPUR | UTTAR PRADESH | 273015 | L-2 | Rejected-Finance BEING L2 BIDDER | |
| 3 | L-3₹48.7 L+₹43,268.96 (0.90%)Rejected-Finance P O RANGIA WARD NO 3 DIST KAMRUP ASSAM | KAMRUP | ASSAM | 781354 | L-3 | Rejected-Finance BEING L3 BIDDER | |
| 4 | L-4₹49.0 L+₹78,685.50 (1.63%)Rejected-Finance RANGIYA STATION ROAD WARD NO 2 PO RANGIYA DIST KAMRUP ASSAM PIN 781365 | BAKSA | ASSAM | 781365 | L-4 | Rejected-Finance BEING L4 BIDDER | |
| 5 | L-5₹49.1 L+₹90,981.68 (1.89%)Rejected-Finance C O DR UMASHANKAR SHARMA RANGIYA TINIALI NEAR RAIL GATE POST RANGIYA DIST KAMRUP ASSAM PIN 781354 | KAMRUP | ASSAM | 781354 | L-5 | Rejected-Finance BEING L5 BIDDER |
| Sl No | Description | Qty | Unit | MUKUL CHOUDHURY L3 | M/S S.S. Construction L5 | M/S SITAL BUILDERS L7 | M/S KIRAN ENTERPRISE L1 | M/s SHARMA BUILDERS & ENGINEERS L4 | JIBAN CHANDRA MEDHI L6 | Shiva Builders L2 |
|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Taking down Chowkhats or frames with shutters (without taking off shutters from the frames) not exc. 1.5 sq. m each, complete all as specified and as directed by Engineer-in-charge. | 10 | EACH | 111 ₹1,110 | 100 ₹1,000 | 79 ₹790 | 100 ₹1,000 | 50 ₹500 Lowest | 125 ₹1,250 | 125 ₹1,250 |
| 2.00 | Taking down Chowkhats or frames with shutters (without taking off shutters from the frames) exc 1.5 sqm but not exc. 4.0 sq. m each, complete all as specified and as directed by Engineer-in-charge. | 4 | EACH | 222 ₹888 | 200 ₹800 | 89 ₹356 | 150 ₹600 | 50 ₹200 Lowest | 150 ₹600 | 150 ₹600 |
| 3.00 | Dismantling timber scantlings 40 sq. cm and over in section, in any position and in unframed work, complete all as specified and as directed by Engineer-in-charge. | 2 | CUM | 444 ₹888 | 500 ₹1,000 | 599 ₹1,198 | 600 ₹1,200 | 250 ₹500 Lowest | 600 ₹1,200 | 600 ₹1,200 |
| 4.00 | Dismantling timber fillets, rails, posts, rafters, purlins, etc. under 40 sq. cm in section and in unframed work, complete all as specified and as directed by Engineer-in-charge. | 80 | RM | 44 ₹3,520 | 10 ₹800 Lowest | 19 ₹1,520 | 50 ₹4,000 | 10 ₹800 Lowest | 25 ₹2,000 | 25 ₹2,000 |
| 5.00 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises, complete all as specified and as directed by Engineer-in-charge. | 191 | SQM | 66 ₹12,606 | 50 ₹9,550 | 39 ₹7,449 Lowest | 50 ₹9,550 | 45 ₹8,595 | 45 ₹8,595 | 45 ₹8,595 |
| 6.00 | Demolition of reed, lathing, single or double, including battens and plaster or chicken wire lathing, complete all as specified and as directed by Engineer-in-charge. | 180 | SQM | 44 ₹7,920 | 15 ₹2,700 Lowest | 19 ₹3,420 | 50 ₹9,000 | 20 ₹3,600 | 20 ₹3,600 | 20 ₹3,600 |
| 7.00 | Demolition of Brickwork or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, complete all as specified and as directed by Engineer-in-charge. | 20 | CUM | 777 ₹15,540 | 400 ₹8,000 | 499 ₹9,980 | 600 ₹12,000 | 250 ₹5,000 Lowest | 650 ₹13,000 | 650 ₹13,000 |
| 8.00 | Demolition of Cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for, complete all as specified and as directed by Engineer-in-charge. | 3.75 | CUM | 444 ₹1,665 | 400 ₹1,500 | 599 ₹2,246.25 | 600 ₹2,250 | 250 ₹937.5 Lowest | 500 ₹1,875 | 500 ₹1,875 |
| 9.00 | Dismantling Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings, complete all as specified and as directed by Engineer-in-charge. | 245 | SQM | 33 ₹8,085 | 30 ₹7,350 | 19 ₹4,655 Lowest | 60 ₹14,700 | 20 ₹4,900 | 20 ₹4,900 | 20 ₹4,900 |
| 10.00 | Dismantling wrought iron or mild steel work of any description not otherwise provided for, complete all as specified and as directed by Engineer-in-charge. | 2.75 | QTL | 555 ₹1,526.25 | 300 ₹825 Lowest | 599 ₹1,647.25 | 600 ₹1,650 | 450 ₹1,237.5 | 500 ₹1,375 | 500 ₹1,375 |
Tender Value
₹36 L
EMD Value
₹72,000
Closing Date
25 Aug 2025, 6:00 pmClosed
GE Rangia
GE Rangia C/O 99 APO Rangia
SPL REP TO BLDG NO ET-332, ET-334 (CHANGSARI) AND PROVN OF TOILET, COMPOUND WALL, DRAIN NEAR MAIN GATE, ELECTRICAL EQUIPMENT AND COVERED SHED OF BLDG NO ET-09 (RANGIA) UNDER GE RANGIA
2025_MES_722457_3
8947/RNG/E8
Open Tender
Civil Works
Item Rate
180 days
CHANGSARI AND RANGIA
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE Rangia
₹72,000
Yes
13 Oct 2025
4 Aug 2025
27 Aug 2025
4 Aug 2025
25 Aug 2025
12 Aug 2025
4 Aug 2025 - 8 Aug 2025
Amount
Taking down Chowkhats or frames with shutters (without taking off shutters from the frames) not exc. 1.5 sq. m each, complete all as specified and as directed by Engineer-in-charge.
Taking down Chowkhats or frames with shutters (without taking off shutters from the frames) exc 1.5 sqm but not exc. 4.0 sq. m each, complete all as specified and as directed by Engineer-in-charge.
Dismantling timber scantlings 40 sq. cm and over in section, in any position and in unframed work, complete all as specified and as directed by Engineer-in-charge.
Dismantling timber fillets, rails, posts, rafters, purlins, etc. under 40 sq. cm in section and in unframed work, complete all as specified and as directed by Engineer-in-charge.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises, complete all as specified and as directed by Engineer-in-charge.
Demolition of reed, lathing, single or double, including battens and plaster or chicken wire lathing, complete all as specified and as directed by Engineer-in-charge.
Demolition of Brickwork or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, complete all as specified and as directed by Engineer-in-charge.
Demolition of Cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for, complete all as specified and as directed by Engineer-in-charge.
Dismantling Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings, complete all as specified and as directed by Engineer-in-charge.
Dismantling wrought iron or mild steel work of any description not otherwise provided for, complete all as specified and as directed by Engineer-in-charge.
Dismantling Wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets, complete all as specified and as directed by Engineer-in-charge.
Surface dressing n exc 15 cm deep and getting out in soft/loose soil, complete all as per specified and as directed by Engineer-in-charge.
Excavation in trenches n.exc 1.5m wide and n.exc 1.5 m in depth for foundation etc or for shafts, wells, cesspits, manholes, pier holes etc. and getting out in soft/loose soil complete all as per specified and as directed by Engineer-in-charge.
M&L for Excavation in post holes (or similar holes) each n.exc 0.5cum in soft/loose soil and getting out, returning filling in and ramming earth or broken rubble mixed with earth around in layers not exceeding 25cm, watering and removing of surplus soil to a distance n.exc 50 meters and making good surface, complete all as per specified and as directed by Engineer-in-charge.
Returning, filling in, including spreading, leveling, watering and well ramming in layers n exc 25cm, including dipositing the surplus soil along the line of pipe/ cable in the form of heap, complete all as per specified and as directed by Engineer-in-charge.
Removing excavated material not exc. 50 m & depositing where directed at a level not exc. 1.5 m above starting point complete all as per specified and as directed by Engineer-in-charge.
M&L for PCC 1:4:8 type D-2 (40mm graded stone aggregate) as in foundations, fillings and mass concrete complete all as per specified and as directed by Engineer-in-charge.
M&L for Hardcore with broken stones/ boulders of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface, complete all as specified and as directed by Engineer-in-charge.
M&L for earth filling, spreading in layers n exc. 30 cm thick; watering, ramming/rolling and finishing to required size, shape, etc., n exc. 1.5 m high from base, complete all as per specified and as directed by Engineer-in-charge. NOTE- Approved quality earth shall be brought by the contractor outside MoD land and cost of transportation also included in unit quoted rate.
M&L for PCC 1:3:6 type C-2 (using 40 mm graded crushed stone aggregate) in surface channels and drains, including necessary formwork, complete all as specified and as directed by Engineer-in-charge.
M&L for Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/ stopped ends, complete all as specified and as directed by Engineer-in-charge.
Add to or Deduct from Item No. 21 here-in-before for Every 25mm Girth or Part thereof Over or Under 30 Cm, complete all as specified and as directed by Engineer-in-charge. Note:- Quantity of this item shall be changed as per site requirement.
M&L for Reinforced Cement Concrete 1:½:3, M-20 (Nominal Mix) (20mm graded stone aggregate) in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete, complete all as specified and as directed by Engineer-in-charge. NOTE : Reinforcement & Formwork will be measured and paid separately under relevant Item.
M&L for Reinforced Cement Concrete 1:½:3, M-20 (Nominal Mix) (20mm graded stone aggregate) in Columns, pillars, piers, posts and struts, complete all as specified and as directed by Engineer-in-charge. NOTE : Reinforcement & Formwork will be measured and paid separately under relevant Item.
M&L for Reinforced Cement Concrete 1:½:3, M-20 (Nominal Mix) (20mm graded stone aggregate) in Beams, cantilevers, bressummers, lintels over 1.5m span, chajjas, complete all as specified and as directed by Engineer-in-charge. NOTE : Reinforcement & Formwork will be measured and paid separately under relevant Item.
M&L for Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter, rough finished flat surfaces of concrete, complete all as specified and as directed by Engineer-in-charge.
M&L for Formwork to sides of pillars, posts, struts, piers, columns and stanchions, rough finished flat surfaces of concrete, complete all as specified and as directed by Engineer-in-charge.
M&L for Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, chajjas, etc. also splays between floors and beams, etc., rough finished flat surfaces of concrete, complete all as specified and as directed by Engineer-in-charge.
S&F of TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and as directed by Engineer-in-charge.
S&F of TMT bars 6-8mm dia, cut to length, bent to shape required, in stirrups, spacers and binders and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and as directed by Engineer-in-charge.
S&F of Mild Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240, complete all as specified and as directed by Engineer-in-charge.
All as per Item No. 31 here-in-above, but for erection & febrication only, complete all as per specified and as directed by Engineer-in-charge.
S&F of mild steel Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment, confirming to Fe 410-W (Gde- E- 250) quality-A, complete all as specified and as directed by Engineer-in-charge.
S&F of mild steel Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165, complete all as specified and as directed by Engineer-in-charge.
S&F of mild steel posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165, complete all as specified and as directed by Engineer-in-charge.
M&L for Brickwork with Sub class B bricks, straight or curved on plan to any radius built and set in cement mortar 1:6, complete all as per specified and as directed by Engineer-in-charge.
M&L for Brickwork with Sub class B bricks, straight or curved on plan to any radius in half brick thick walls built and set in cement mortar 1:4, complete all as per specified and as directed by Engineer-in-charge.
M&L for Rendering 10mm thick in cement morter 1:6 on fair faces of brick work or concrete surfaces/ one side of lathing, finished even and smooth (without using extra cement), complete all as specified and as directed by Engineer-in-charge.
M&L for Rendering (Externally) 15mm thick in Cement Mortar 1:4 in two layers on other than fair faces Brick Walls/Concrete Surfaces/ other side of lathing, 5mm thick top layer mixed with WPC as per Manufactures instruction, plastered surfaces finished Even and Smooth without using Extra Cement, complete all as specified and as directed by Engineer-in-charge. NOTE: WPC shall be Measured and Paid as ‘Supply only’ under relevant Item.
Supply only Integral waterproofing compound, complete all as specified and as directed by Engineer-in-charge.
M&L for providing 100 mm thick Cement concrete type D-2, 1:4:8 (40mm graded stone aggregate) as in sub-base of floor/ path/ hardstanding/plinth protection, etc. or similar works, laid in altenate bays including use and waste of form work and finishing concrete surfaces even and rough, complete all as per specified and as directed by Engineer-in-charge.
M&L for providing 75 mm thick Cement concrete type C-2, 1:3:6 (40mm graded stone aggregate) as in floor/ path/ hardstanding/plinth protection, etc. or similar works, laid in altenate bays including use and waste of form work and finishing concrete surfaces even and fair, complete all as per specified and as directed by Engineer-in-charge.
M&L for providing 40 mm thick Cement concrete type B-1, 1:2:4 (20mm graded stone aggregate) as in base of floor/ path/ hardstanding/plinth protection, etc. or similar works, laid in altenate bays including use and waste of form work and finishing concrete surfaces even and rough, complete all as per specified and as directed by Engineer-in-charge.
M&L for providing Non-skid Ceramic coloured tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc., laid over 20mm thick cement screed 1:6 set and jointed in neat cement slurry and pointed in white or coloured cement to match, complete all as per specified and as directed by Engineer-in-charge.
M&L for providing Non-skid Ceramic coloured tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.36 sqm, in floors etc., laid over 20mm thick cement screed 1:6 set and jointed in neat cement slurry and pointed in white or coloured cement to match, complete all as per specified and as directed by Engineer-in-charge.
M&L for providing Non-skid Ceramic coloured tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.36 sqm in vertical surface (like skirting, dado, etc.), over 10mm thick cement screed 1:3 set and jointed in neat cement slurry and pointed in white or colour cement to match, complete all as per specified and as directed by Engineer-in-charge.
M&L for providing Glazed ceramic coloured tiles in vertical surface (like skirting, dado, etc.) 300x 450x 7 mm thick, over 10mm thick cement screed 1:3 set and jointed in neat cement slurry and pointed in white or colour cement to match, complete all as per specified and as directed by Engineer-in-charge.
M&L for providing glossy finished Chequered cement concrete coloured tiles 30cm x 30cm x 25mm thick, set, jointed and pointed in neat cement slurry in floors., laid over 20mm thick cement screed 1:6 with grey cement and pigments to match, complete all as per specified and as directed by Engineer-in-charge.
S&F of Steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded, complete all as specified and as directed by Engineer-in-charge.
S&F of Steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete without glazing bars, dovetailed or welded, complete all as specified and as directed by Engineer-in-charge.
S&F of Steel ventilator with top hung shutter including hinges, steel peg stay, complete all as specified and as directed by Engineer-in-charge.
S&F of Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube; complete all as specified and as directed by Engineer-in-charge.
S&F of Solid PVC Frame for double door shutter of size 50mm x 95mm made out of 5mm thick one side prelaminated other side plain colour PVC sheet reinforced with M.S. Square tube; complete all as specified and as directed by Engineer-in-charge.
S&F of Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement; complete all as specified and as directed by Engineer-in-charge.
S&F of Factory Made Solid PVC Moulded Door Shutter With wood free EPS, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick Moulded Prelam PVC Sheet on the front face & 2mm prelam PVC Sheet on back face; complete all as specified and as directed by Engineer-in-charge.
S&F of Factory made wire gauzed PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of wire gauzed shall be wrapped on an additional square 8mm M.S. Solid tube and this tube shall be welded to M.S. tubes; complete all as specified and as directed by Engineer-in-charge. NOTE- Cost of wire mesh shall deemed to be included in unit quoted rate.
S&F of 3mm thick Sheet glass, ordinary quality and glazing with oil putty in square not exc 0.5 sq. m in each pane, complete all as specified and as directed by Engineer-in-charge.
S&F in-repair of Galvanised mild steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks, or galvanised wire staples, complete all as specified and as directed by Engineer-in-charge.
S&F of 100 mm long Butt hinges, medium weight, galvanised mild steel, complete all as specified and as directed by Engineer-in-charge.
S&F of 150 mm long Extruded aluminium alloy handles, fabricated type, anodised, complete all as specified and as directed by Engineer-in-charge.
S&F of 150 mm long Aluminium anodised, barrel tower bolts of extruded section, complete all as specified and as directed by Engineer-in-charge.
S&F of 300 mm long Mild steel sliding door bolts, plate type, stove enamelled black, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate, complete all as specified and as directed by Engineer-in-charge.
S&F of Mild steel 300mm long, ordinary rat tail rod pattern springs including roller and roller plate, complete all as specified and as directed by Engineer-in-charge.
S&F of exposed powder coated GI snap grid frame work (600x600 mm) for false ceiling comprising of wall/cleat angle of size 25x25x0.35mm and cross tee of size 24x38x0.70mm with suspended hangers of 2 mm dia. G.I. (upto 1200mm length) adjusting level fixed to any type of roof by means of ceilling cleats with and including Supply & fixing/ laying/ inserting of pre-painted (white) 4mm thick designer classic E-boards (595x595 mm) to GI frame work, complete all as specified and as directed by Engineer-in-charge.
S&F of 0.50mm thick Pre-painted galvalume aluminum zinc coating GI based trapizoidal profile (Hi-Rib) steel sheet of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws, complete all as specified and as directed by Engineer-in-charge.
S&F of 0.50mm thick Pre-painted galvalume aluminum zinc coating GI based plain steel sheet of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws, complete all as specified and as directed by Engineer-in-charge.
M&L for preparing newly plastered surfaces of wall and applying three coats of white wash, complete all as specified and as directed by Engineer-in-charge.
M&L for preparing newly plastered surfaces of wall and applying two coats of cement base paint of any shade over a coat of alkali-resistant priming paint, complete all as specified and as directed by Engineer-in-charge.
M&L for preparing newly plastered surfaces of wall and applying two coats of distemper oil emulsion of any shade over a coat of chalk whitening, complete all as specified and as directed by Engineer-in-charge.
M&L for preparation of new or previously un-treated steel/iron surfaces of any description, not otherwise described, over 10cm width or girth and applying two coats of Synthetic enamel paint (1st quality) of any tint over a coat of red oxide primer, complete all as specified and as directed by Engineer-in-charge.
M&L for preparation of old painted steel/ iron surfaces of any description, not otherwise described, over 10cm width or girth and applying one coat of Synthetic enamel paint (1st quality) of any tint, complete all as specified and as directed by Engineer-in-charge.
S&F of Rotational Moulded Polyethylene Water Storage Tank 1000 Litre capacity (Cylindrical Vertical with Closed Top), 3 layered, hoisted and fixed in position, all as specified in MES Schedule Part-I with and including providing 20 mm dia ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed (Minimum weight 210gm), complete all as specified and as directed by Engineer-in-charge.
S&F of 15mm dia galvanised steel tubes, 'medium grade', with all fitting; fixed to walls and ceilings or laid in floors, complete all as specified and as directed by Engineer-in-charge.
S&F of 20mm dia galvanised steel tubes, 'medium grade', with all fitting; fixed to walls and ceilings or laid in floors, complete all as specified and as directed by Engineer-in-charge.
S&F of Vitreous China wash basin oval counter top type, white, self rimming basin, flat back, size 560x400x205mm including fixing of 15mm dia 450mm long PVC connection pipe and 32mm dia 900mm long PVC Flexible waste pipe with and including 32mm dia Waste fittings, brass, chromium plated for glazed ware sinks, basins, etc., complete all as specified and as directed by Engineer-in-charge.
S&F of Vitreous China bowl type urinal flat back, size of 465 x 355 x 265 mm white with and including grating, 15mm dia 450mm long PVC connection pipe and 32mm dia 900mm long PVC Flexible waste pipe, 15mm dia PTMT urinal spreader (minimum wt. 60gms) and providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long CP brass screws, pointing around urinal back in putty; complete all as specified and as directed by Engineer-in-charge.
S&F of Wash down couple water closet (Cistern mounted) pan and S/P trap of 670x365x740mm with and including Plastic water closet seat, white, closed pattern with flat bottom, and cover and mild steel chromium plated or anodised aluminium hinging device including connection to drain (or outgoing pipe) and antisyphonage pipe, etc., complete all as specified and as directed by Engineer-in-charge.
S&F of Brass chromium plated Tubular towel rail, 20mm dia, D type, 60cm long between flanges, complete all as specified and as directed by Engineer-in-charge.
S&F of Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position, complete all as specified and as directed by Engineer-in-charge.
S&F of 15 mm dia fancy type chromium plated Bib taps, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule, complete all as specified and as directed by Engineer-in-charge.
S&F of 15 mm dia fancy type chromium plated two-way Bib taps, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule, complete all as specified and as directed by Engineer-in-charge.
S&F of 15 mm dia fancy type chromium plated Pillar taps, cast copper alloy, with capstan heads, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe, complete all as specified and as directed by Engineer-in-charge.
S&F of 15 mm dia fancy type, chromium plated Stop valves/ Angle valve, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions, complete all as specified and as directed by Engineer-in-charge.
S&F of 110mm dia PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to walls, complete all as specified and as directed by Engineer-in-charge.
S&F of 75mm dia PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to walls, complete all as specified and as directed by Engineer-in-charge.
S&F of 110mm dia PVC (SWR) bends any radius, complete all as specified and as directed by Engineer-in-charge.
S&F of 75mm dia PVC (SWR) floor trap, plain with grating including jointing with solvent cement, complete all as specified and as directed by Engineer-in-charge.
S&F of stainless steel Grating doom of 100 mm dia with waste pipe hole, complete all as specified and as directed by Engineer-in-charge.
S&F of PVC connection pipe 15mm dia with PTMT nuts of length 450mm, complete all as specified and as directed by Engineer-in-charge.
S&F of 150 mm internal diameter of double wall corrugated (DWC) high density polyethelene pipes (HDPE) and stiffness classes-8 (SN-8) with ISI marked (with CML no) with and including all fitting & jointing material for sewage line and laid in trenches as specified in IS 16098-2013 part-2 complete all as per specified and as directed by Engineer-in-charge. MAKE- Sintex/ Supreme/ Astral
S&F for 32mm dia High density poly ethylene pipes (HDPE) of pressure rating 6 kg/ cm2 fixed to walls and ceilings or laid in floors, complete all as specified and as directed by Engineer-in-charge.
M&L for cutting chases, pinning in brick walls making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth, complete all as per specified and as directed by Engineer-in-charge.
Taking down carefully copper/alumunium point wiring for light, fan, bell, socket or power complete including fittings such as switches, ceiling roses pendents regulators, sockets, light fittings etc, removing materials from site and making good distrubed surface of wall, floors, etc. complete all as specified and as directed by Engineer-in-charge.
Taking down old unserviceable earthing of any description, complete all as specified and as directed by Engineer-in-charge.
M&L for disconnecting and taking down ceiling fan/ exhaust fan of any sweep, sealing cable end, dismantling blades and keep fan and blades in safe custody and re-fixing the same into existing position after proper cleaning and painting with synthetic enamel paint by spray painting, complete all as specified and as directed by Engineer-in-charge.
M&L for point wiring with 1.5 sqmm size (nominal area) PVC insulated unsheathed single core multi stranded FRLSH copper conductor cable drawn into and incl concealed (on wall only) PVC conduit (medium grade) with fittings of adequate dia and length with all accessories and fittings like bends, elbow, crosses, etc. with modular terminal boxes with cover plate and frame for mounting fittings like; switches, sockets, fan regulator, etc. incl 1.5 sqmm size PVC insulated multistranded FRLSH copper conductor cable as earth continuity conductor and connected to earth dolly for one light/ fan/ exhaust fan/ bell point controlled by one 1-way switch/ bell push, complete all as per specified and as directed by Engineer-in-Charge.
All as per Item No. 97 here-in-above, but for One 3 pin socket outlet, 5/6 Amps, on same board, complete all as specified and as directed by Engineer-in-charge.
All as per Item No. 97 here-in-above, but for One 3 pin socket outlet, 5/6 Amps, independent board, complete all as specified and as directed by Engineer-in-charge.
All as per Item No. 97 here-in-above, but for One 3 pin socket outlet, 15/16 Amps, independent board, with cables 2.5 sq. mm size, complete all as specified and as directed by Engineer-in-charge.
S&F Modular Switch, One Module, 1-Way, 5/6 Amps, 240 Volt, conforming to IS and connecting up, complete all as specified and as directed.
S&F Modular Switch, One Module, 1-Way, 15/16 Amps, 240 Volt, conforming to IS and connecting up, complete all as specified and as directed.
S&F Modular Socket, 2/3 Pin, combined, Two Module, 5/6 Amp, 240 Volt, conforming to IS and connecting up, complete all as specified and as directed.
S&F Modular Socket, 2/3 Pin, combined, Two Module, 15/16 Amp, 240 Volt, conforming to IS and connecting up, complete all as specified and as directed.
S&F of ceiling rose surface backelite three terminals, PVC/ polycarbonate, insulated body, complete all as specified and as directed by Engineer-in-charge.
S&F of stepped type modular electronic fan regulator, 120W, 2-module, 220-240V, AC, complete all as specified and as directed by Engineer-in-charge.
S&F of Sub-main Wiring with 2-Runs of Single Core 6.0 Sq mm PVC insulated FRLSH multi-stranded 1100 Volts grade with Copper Conductor drawn through and including PVC conduit (medium grade) ISI marked and its Accessories including 1-Run of Single Core 6.0 Sq mm PVC insulated FRLSH unsheated multi-stranded 1100 Volts grade with Copper Conductor Cable as Earth Continuty Conductor along with the Wiring and connected from DB to DB/Main Board, complete all as specified and as directed. NOTE :- (a) Cost of PVC conduit (medium grade) with all Fittings/Accessories will deem to be included in the quoted UNIT RATE. (b) Cables as mentioned in SCHEDULE ‘A’ Items and 1-Run of PVC conduit with all Fittings/Accessories will be measured and paid as ONE UNIT. (c) Sub-main Wiring will be measured as length of PVC conduit only. Wire required for looping, etc as ordered will deem to be included in the quoted UNIT RATE.
S&F in-repair of Sheet Metal Enclosure MCB DB SPN, 12 way 240 volt, with rated Bus-bar, Double door type MCB DB suitable for mounting incoming and outgoing MCBs of any type, complete all as specified and as directed by Engineer-in-charge.
S&F in-repair of Sheet Metal Enclosure MCB DB SPN, 8 way 240 volt, with rated Bus-bar, Double door type MCB DB suitable for mounting incoming and outgoing MCBs of any type, complete all as specified and as directed by Engineer-in-charge.
S&F of Sheet Metal Enclosure MCB DB SPN, 4 way 240 volt, with rated Bus-bar, Double door type MCB DB suitable for mounting incoming and outgoing MCBs of any type, complete all as specified and as directed by Engineer-in-charge.
S&F of RCCB Double Pole (DP), 40 Amps, breaking capacity 30mA, 240 Volt for fixing on DB’s, 10 KA, 50 Hz, conforming to IS/IEC 61008-1, connecting up and testing, complete all as specified and as directed by Engineer-in-charge.
S&F of RCCB Double Pole (DP), 25 Amps, breaking capacity 30mA, 240 Volt for fixing on DB’s, 10 KA, 50 Hz, conforming to IS/IEC 61008-1, connecting up and testing, complete all as specified and as directed by Engineer-in-charge.
S&F of MCB Single Pole & Neutral (SPN), 'C' Curve, 32 Amps, 240 Volt for fixing on MCB DB’s, 10 KA, 50 Hz, conforming to IS/IEC 60898, connecting up and testing, complete all as specified and as directed by Engineer-in-charge.
S&F of MCB Single Pole (SP), 'C' Curve, 6-32 Amps, 240 Volt for fixing on MCB DB’s, 10 KA, 50 Hz, conforming to IS/IEC 60898, connecting up and testing, complete all as specified and as directed by Engineer-in-charge.
S&F of exhaust fan, sturdy engineering plastic body, AC single Phase, 230V of size 250mm sweep with, blades, frame and louvers including connecting up with three core flexible copper cables of suitable size, complete all as specified and as directed by Engineer-in-charge.
S&F of surface and wall mounted LED tube light fitting (separate batten and rod shall be measured as single unit) 1x 20W, (4 Feet) with aluminium housing & integrated electronic driver, 6500K, 220-240 Volts, AC decorative regal type with and including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose to fitting, complete all as specified and as directed by Engineer-in-charge.
S&F of surface and wall mounted LED light fitting mirror type 1x 10W, (2 Feet) with aluminium housing & integrated electronic driver, 6500K, 220-240 Volts, AC decorative box type with and including LED lamp connecting up with three core flexible copper conductor cable of suitable size from ceiling rose to fitting, complete all as specified and as directed by Engineer-in-charge.
S&F of slim square panel LED luminaire with frame 600 mm x 600 mm, white powder coated with CRCA housing, 35/36 watt, 220-240 V, AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cables of suitable size, complete all as specified and as directed by Engineer-in-charge.
S&F of Energy saving new generation environmental friendly long life versatile presure die cast aluminium housing IP 66 building security light fitting luminaire with high power LEDs as light source and electronic driver of capacity 25 watts with pre wired and lens embedded PC cover having Bottom opening seperate driver compartment and Impact resistance of IK08 with necessary mounting arrangements, complete all as specified and as directed by Engineer-in-charge.
S&F of bracket suitable for LED Street light fitting/ house service bracket made out of 25mm bore (Dia) medium grade GI pipe of 0.6m long, bend to required shape, including necesary clamps (Mild Steel Flat iron of 25x5mm) for fixing of building security/ street light fitting as per existing and painting the MS Flat iron with two coats of synthetic enamel paint, complete all as specified and as directed by Engineer-in- Charge.
M&L for Sand Cushioning (dry) in trenches/ducts for protection of UG Cables (below, above and around the UG Cable laid in Trenches) of 230mm Spread thickness (8 Cm in depth before laying the Cable and 15 Cm in depth after laying the Cable) and consolidated (punned) upto 180mm thickness, complete all as per specified and as directed by Engineer-in-charge. NOTE : For the purpose of Payment, Punned thickness of Sand Cushioning only will be measured and paid for.
Supply & Laying Fly ash Bricks, laid breadth wise along the length of cable laid in trenches over sand cushion laid for UG cable protection, complete all as specified and as directed by Engineer-in-charge.
Supply & laying of LT XLPE insulated cable, sheathed, screened, PVC bedded, Galvanised Steel Strip or Wire armoured, Electic Power Cable (heavy duty) with Aluminium Conductor, 1100 Volts grade, cross-sectional area 95 Sqmm 3½ Core, laid in Pipe/ Ducts/ Trenches/ under Floor/ under Road/ fixing on pole/ above floor including testing, complete all as specified and as directed by Engineer-in-charge. NOTE : Earthworks, Sand Cushioning, Bricks, GI Pipe, etc. will be measured and paid under appropriate Items.
Supply, install, testing and commissioning of diesel engine driven generating set 62.5 KVA(50 KW) , 415V AC 3 Phase 4 wire 50Hz supply, (voltage regulation at ±1% of rated voltage from no load to load with Electronic Regulator) 1500 RPM, 0.8 PF (lagging) complete with standard AMF control panel, confirming to CPCB IV+, sturdy welded channel iron common base frame both for prime mover and alternator, anti- vibration pads etc, as specified by the manufacturer and comprising of following : (a) Prime mover shall be water cooled type, 1500 rmp under NTP conditions to drive the alternator complete with standard fittings, electric start arrangement including maintenance free batteries with connecting leads and terminals and charging system for batteries. Over load capacity shall be 10% for 1 hour in 12 hours operation. The prime mover shall have the following features: (i) Fuel pump as supplied by OEM (ii) Electronic governor (iii) Turbo charger, pulse tuned exhaust manifold, stainless steel exhaust flexible connection (iv) Radiator, coolant inhibitor, Low temperature after cooling (LTA) (V) lub oil cooler (vi) Full flow paper element filters-fuel, lube oil and by-passs (vii) Dry type replaceable paper element for air cleaner with restriction indicator (viii) Fly wheel housing & fly wheel to suit single bearing Alternator (ix) Starting Electric battery charging alternator (x) first fill lub oil (b) Fuel Storage Tank of adequate capacity for 12 hrs run along with cover, locking arrangement, level indicator in litres, inlet strainer, fuel out let, air vent, drain plug, incl MS Staging to the required height, fuel line up to DG Set with MS pipe of suitable dia, Fuel transfer pump with By pass connecting system all as per Manufacturer's recommendations. (c) Alternator shall confirm to IS-4722 of 1968 in SPDP constructions with IP23 degree of protection, Class 'H' insulation for Stator, Rotor and Exciter. Brashless excitation system with exciter filed supplied from the solid state regulator.
M&L for earthing complete with galvanised steel earth plate electrode of size 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below ground level, connected to galvanized earth wire 4.00 mm dia by means of bolts nuts check nuts & washers of galvanized iron or steel , procteded by GI pipe 15 mm bore( light grade) and watering pipe 20 mm bore GI pipe (medium grade) and chamber and coping shall be in PCC 1:3:6 type C1 using 20mm graded stone agg. 50 mm thick cover of RCC 1:2:4 type B1 using 20 mm graded stone agg. reinforced with 8 mm dia MS tor bar @ 80 mm c/c both ways including excvation and earth work and removal of surplus soil complete all as shown in electrical plate no 3 of SSR PT 1, 1991 with charcoal dust and salt complete and earth lead connected to earthing test point (up to main switches, DBs), complete all as specified & testing on completion. NOTE:- (i) Item includes the cost of 1.5 mtr length GI pipe for protection for GI earth wire. (ii) item rates includes the cost of 7.5 mtr GI earth wire.
All as per Item No.-125 here-in-above, but using 32x6mm galvanised earth strip as earth wire and protected with 40mm dia light grade glavanised pipe, complete all as specified & testing on completion.
M&L for laying 32mm dia (Outer) 3- layer PP-R (Polypropylene random copolymer) concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply with all PP-R plain & brass threaded fittings laid in trenches/ fixed to wall and testing, complete all as specified and as directed by Engineer-in-charge.
S&F of 32mm dia (Outer) PP-R Gate valves (brass insert), complete all as specified and as directed by Engineer-in-charge.
Shiva Builders (BID ID -3393447)
MUKUL CHOUDHURY (BID ID -3394809)
M/s SHARMA BUILDERS & ENGINEERS (BID ID -3397253)
M/S S.S. Construction (BID ID -3395207)
JIBAN CHANDRA MEDHI (BID ID -3394450)
M/S SITAL BUILDERS (BID ID -3396460)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .