Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.0 LAccepted-AOC | L1 | Accepted-AOC BEING L1 | |
| 2 | L2₹25.3 L+₹1.3 L (5.43%)Rejected-Finance | L2 | Rejected-Finance BEING NOT L1 | |
| 3 | L3₹26.2 L+₹2.2 L (9.31%)Rejected-Finance | L3 | Rejected-Finance BEING NOT L1 | |
| 4 | L4₹26.3 L+₹2.3 L (9.51%)Rejected-Finance | L4 | Rejected-Finance BEING NOT L1 | |
| 5 | L5₹27.2 L+₹3.2 L (13.4%)Rejected-Finance FLAT NO 201 GREEN VALLEY CHS PLOT NO 26 SECTOR 19 NERUL EAST NAVI MUMBAI 400 706 | THANE | MAHARASHTRA | 400706 | L5 | Rejected-Finance BEING NOT L1 |
Tender Value
Refer Docs
EMD Value
₹60,000
Closing Date
25 Jan 2021, 6:00 pmClosed
GE NW KARANJA
NAVAL STATION KARANJA, URAN, RAIGAD, MAHARASHTRA
REPAIR REPLACEMENT OF METER PANELS MS SHEET METAL ENCLOSURE SUBMAIN WIRING DBS CONTROL SWITCH AND OTHER MISC WORKS AT MD ACCN OTM ACCN AT NAVAL STATION KARANJA
2020_MES_408043_1
8329/E8
Open Tender
Electrical and Maintenance Works
Item Rate
240 days
GE NW KARANJA
REPAIR REPLACEMENT OF METER PANELS MS SHEET METAL ENCLOSURE SUBMAIN WIRING DBS CONTROL SWITCH AND OTHER MISC WORKS AT MD ACCN OTM ACCN AT NAVAL STATION KARANJA
8 documents required · 8 mandatory
₹500
Yes
GE NW KARANJA
₹60,000
Yes
8 Mar 2021
30 Dec 2020
27 Jan 2021
30 Dec 2020
25 Jan 2021
13 Jan 2021
30 Dec 2020 - 13 Jan 2021
Amount
Taking down carefully copper/aluminium point wiring( light, fan socket or power)through steel / pvc conduit / casing caping (fitting such as switchs, ceiling croses , pendants regulators socket etc to be measured separately.) removing material to store for keeping in safe custody for reuse at site and making good disturbed surfaces of floor etc. all as specified and directed.
M & L for point wiring with 1.5 sqmm (nominal area) PVC insulated and unsheathed multistranded FRLS copper conductor cable (using colour code as per IS) 1100 volts grade drawn through and including PVC CASING CAPPING(ISI marked) with all accessories including surface / concealed sheet steel terminal / CI box with 3 mm thick hylam / masonite sheet top cover including 1.5 sqmm size PVC insulated unsheathed copper conductor multistranded cable for continuous earth conductor ( using green colour) to common earth and connecting to earth dolly, complete all as specified & directed for One light /fan/bell point controlled by one switch 5 Amp, SP, one way 240 volts.
All as per item No 2 above but One 5 Amp, 3 Pin socket point on the same board all as specified and directed.
All as per item No 2 above but One 5 Amp, 3 Pin socket point independent all as specified and directed.
All as per sl item No 2 above, but using 2.5 sqmm (nominal area) PVC insulated and unsheathed multistranded FRLS copper conductor cable for phase & 2.5 sqmm PVC insulated unsheathed multistanderd copper conductor cable for earth continuity ( green colour) for one 3 pin socket outlet 15 Amp multi purpose independent controlled by 15 Amp switch, SP, one way, 240 Volts & socket, complete all as specified and directed.
All as per sl item No 2 above, but using 4 sqmm (nominal area) for phase and 4 sqmm PVC multistanderd FRLS copper conductor cable for earth continuity ( green colour) for one 15 Amp socket point controlled by 15 Amp switch, SP, one way, 240 Volts & socket, complete all as specified and directed.
S & F switch piano flush button single pole one way 5 Amps (ISI marked ) complete all as specified and directed.
S & F for Buzzer AC 230 Volts singel pole (ISI marked) Make Anchor or equivalent complete all as specified and directed.
S & F for Bell push flush type 5 Amp (ISI marked) complete all as specified and directed.
S & F switch socket outlet 2-in-1, 3 pin 6 A controlled by one switch (ISI marked) complete all as specifed and directed.
S & F switch socket combination 5-in-1, 5A/15 A controlled by one switch (ISI marked) Make as prroved in command list.
S & F ceiling rose surface bakelite 65 x 50 mm three terminals complete (IS marked) as per all as specified and directed.
S & F EME rotary step fan regulator suitable for operation in 230 V, AC, 50 Hz complete all as specified
S & F in repair Earth plug & socket board SP & N enclosure with 2 pole and earth metal plug & socket 20A, 240 V with and including one MCB SP 20A, 240V complete all as specified and directed.
S&F 6 to 32 Amp MCB single pole 240 V 10 KA (C-Series) all as specified and directed.
S & F SPN MCB 240 V 50 Hz 10 KA confirming to IS 8828 of rating 32 Amp as per as in repairs all as specified and directed.
S & F TPN MCB 415 V 50 Hz 10 KA confirming to IS 8828 of rating 40 to 63 Amp all as specified and directed.
Supply and fix in repair modular switch 1 module 6 amp one way ISI marked all as specified and directed.
Supply and fix in repair modular switch 1 module 16 amp one way all as specified and directed.
Supply and fix in repair modular socket 2 module universal type 5/6 amp one way all as specified and directed.
Supply and fix in repair modular socket 2 module universal type 15/16 amp one way all as specified and directed.
Supply and fix in repair modular bell push with indicator all as specified and directed.
BLANK
Supply and fix modular cover plates with frame up to 4 module as per site requirements apart from the rates included in the point wiring for cover plates and metal flush boxes which is catered for new point wiring in item no 2 above. NOTE-cover plates considered in this item only for the maintanance of switches of existing modular fitting qtrs all as specified and directed.
Supply and fix modular cover plates with frame 6 to 8 module as per site requirements apart from the rates included in the point wiring for cover plates and metal flush boxes which is catered for new point wiring in item no 2 above .NOTE-cover plates considered in this item only for the maintanance of switches of existing modular fitting qtrs all as specified and directed.
Supply and fix modular metal flush box as per site requirements 6 to 8 modules complete all as specified and directed. NOTE-metal flush boxes considered in this item only for the maintanance of switches of existing modular fitting qtrs all as specified and directed.
S & F in repair switch piano flush button single pole one way, 6 Amp (ISI marked) complete all as specified and directed by Engineer-in-Charge
S & F in repair socket outlet 2 in 1, 3 pin, 6 Amp flush type (ISI marked) complete all as specified and directed by Engineer-in-Charge.
S & F EME rotary step fan regulator suitable for operation in 230 V, AC, 50 Hz complete all as specified
S & F in repair switch socket 2 in 1, 3 pin, 6 Amp flush type (ISI marked) complete all as specified and directed by Engineer-in-Charge.
M & L for submain wiring with 2 runs of single core 6 sqmm PVC insultaed, unsheathed multi stranded copper concuctor cable, 1100 Volts conforming to IS-694 1990 with ISI mark, drawn through and including laying of PVC conduit 25 mm bore size including one run of 6 Sqmm PVC insulted multistanded copper conductor cable, 1100 Volts grade conforming to IS -694, 1990 green colour for earth contuinity and connecting up to common earth dolly complete all as specified and directed. Note:- Two run of 6 Sqmm and one run of 6 Sqmm earth wire will be measured as one running metre
M & L for submain wiring with 4 runs of single core 6 sqmm PVC insultaed, unsheathed multi stranded copper conductor cable, 1100 Volts grade conforming to IS-694 1990 with ISI mark, laying and drawn through PVC conduit 25 mm bore size including one run of 6 Sqmm PVC insulted multistanded copper conductor cable, 1100 Volts grade conforming to IS -694, 1990 green colour for earth continuity and connecting up to common earth dolly complete all as specified and directed. Note:- Three runs of 6 sqmm cable, one run of 6 sqmm earth wire will be measured as one running metre
S & F MCB SPN distribution board sheet steel, phosphorised powder painted MCB DBs with busbar neutral link, earth bar and DIN rail conforming to IS, 4 way double door, 230 volts, 50 HZ, AC complete all as specified and directed.
All as per item No 33 above but 8 way double door all as specified and directed by engr-in-charge.
S & F in MCB distribution board TPN, 4 ways, 415 Volts, 50 Hz, AC, double door made out of sheet metal phosphatised and painted with epoxy polyster based powder paints with 200 Amps rated bus bar and earth bar, ISI marked complete all as specified and directed.
All as per item No 35 above 8 way double door complete all as specified and directed.
S&F in repair double door MCCB DB VTPN 4 way made out of 18SWG CRCA steel sheets, Phosphates powder coated with copper bus bar, Earth stud, Din Rail, Polyamide Terminal Blocks for incoming and outgoing circuits, inbuilt loose wire box, Ground terminal blocks, with thimble flame retardant copper conductors and 250 Amps rated bus bar double door open able complete, including taking out old unsv MCB DB any size/type.
S & F in repair MCCB 3 Pole, thermal release range 63-80 Amps of breaking capacity 25 kA, 415 Volts, 50 Hz, Series complete all as specified
S & F in repair MCCB 3 pole, thermal release range 80-100 Amps of breaking capacity 25 kA, 415 Volts, 50 Hz, Series complete all as specified
S & F in repair MCCB 4 pole, thermal magnetic release range 63-80 Amps of breaking capacity 25 kA, 415 Volts, 50 Hz, Series complete all as specified and directed.
Supply and fix LED batten including 18W LED tube light in wall/surface connecting with all required accessories like PVC box base,flexible cable from ceiling rose etc Surface and wall mounted LED batten, Engineering plastic batten and 18W tube light rod as directed and specified by engr-in-charge. Make as approved in command list.
Supply and fix LED batten including LED tube light 10w 2ft in wall/surface connecting with all required accessories like flexible cable from ceiling rose etc as directed and specified by engr-in-charge. Make as per command approved list.
S & F LED tube rod 20 watt change with existing 36 watt tube rod complete all as specified and directed.
Checking of earth resistace and continuity in all married accomodation DBs and all points and checking of voltage differences in between earth and neutral points between phase and neutral /phase and earth also making Register and properly note down the value volts of initial and rectified value and also getting signature from engr-in charge will also includes in the job. NOTE:-checking should be carried out through Digital multi meter of reputed company of ISI marked and will get approved from engr-in-charge before commencing testing and the required sub main wiring and point wiring required for rectification will mesured and paid under relevent item above
Material and labour for enhancement of soil resistivity of earthing by Taking out pit cover and filling salt water through watering pipe of earth pit for improvement of earth resistance complete all as specified and directed by engr-in-charge.
Supply and fixing LED building security light fitting with suitable size bracket/angle to fit security light of 45w IP 66 protection LED complete all specified and directed.
Supply and fixing LED building security light fitting with suitable size bracket/angle to fit security light of 60w IP 66 protection LED complete all specified and directed.
Supply and fix LED recess mounted 2x2 luminarie 36w fitting Make as per appoved command list complete all as specified and directed by engr-in-charge.
S & F in repairs / replacement LED PL-L ultra bright lamp 18 watt as per sample complete all as specified and directed by Engineer-in-Charge. Make as per approved command list.
Supply and fix LED recess mounted Spot light 12W alongwith 12W driver complete including taking down of existing light, colour of light as directed Engr-in-Charge. Make as per appoved command list.
Supply and fixing wall mounted meter & DB box of suitable size having internal depth not less than 30cm made by not less than 2.0mm thick of CRCA sheet having dobule door duly powder coated paint,manufacturered by CPRI approved factory, including making all arrangements for fixing the meter box on the wall at suitable place (To be decided by Engr-in-charge) duly locking arrangement, cable glands etc and confirming the following and locking arrangement, complete all as specified and directed INCOMING (1) MCCB 100 AMP 4 P 25 kA, 415 Volts, 50 Hz thermal magnetic based with o/c, s/c protection & ROH - 01 nos (b) Copper bus bar for phase and neutral having 150 Amp rated capacity mounted over the PVC/Porcelean insulators duly enclosed into the busbar chamber with locking arrangements and having colour coded sleeves of R Y B and green colour. (c) Suitabel Insulated sheild -03 Nos and spreaders set of four - 02 nos
OUT GOING :(1) 40 amp MCB DP 10 ka with enclosure-09 nos. (2) Space for refixing existing electrical meter -09 nos. (2) refixing of electric energy meter retrived from site after duly caliberation and including carying out proper wiring from busbar to SPN MCB and MCB to KWH meter through single core 6 sqmm, FRLS multistranded copper conductor of proper colour code. (3) Multifunctional digital meter showing amp, volt, frequency etc.-01 (4) LED phase indicator-01 set. NOTE-Contractor should visit the site and to prepare panel as per size required to fit in below stair case complete all as specified and directed by Engr-in-charge
Supply and fixing wall mounted meter & DB box of suitable size having internal depth not less than 30cm made by not less than 2.0mm thick of CRCA sheet having dobule door duly powder coated paint,manufacturered by CPRI approved factory, including making all arrangements for fixing the meter box on the wall at suitable place (To be decided by Engr-in-charge) duly locking arrangement, cable glands etc and confirming the following and locking arrangement, complete all as specified and directed INCOMING (1) MCCB 63 AMP 4 P 25 kA, 415 Volts, 50 Hz thermal magnetic based with o/c, s/c protection & ROH - 01 nos (b) Copper bus bar for phase and neutral having 100 Amp rated capacity mounted over the PVC/Porcelain insulators duly enclosed into the busbar chamber with locking arrangements and having colour coded sleeves of R Y B and green colour. (c) Suitabel Insulated sheild -03 Nos and spreaders set of four - 02 nos
OUT GOING :(1) 40 amp MCB DP 10 ka with enclosure - 05 nos. (2) refixing of electric energy meter 05 Nos retrived from site after duly caliberation and including carrying out proper wiring from busbar to SPN MCB and MCB to KWH meter through single core 6 sqmm, FRLS multistranded copper conductor of proper colour code. (3) Multifunctional digital meter showing amp, volt, frequency etc.-01 (4) LED phase indicator-01 set. NOTE-Contractor should visit the site and to prepare panel as per size required to fit in below stair case complete all as specified and directed by Engr-in-charge
Supply and fixing wall mounted meter & DB box of suitable size having internal depth not less than 30cm made by not less than 2.0mm thick of CRCA sheet having dobule door duly powder coated paint,manufacturered by CPRI approved factory, including making all arrangements for fixing the meter box on the wall at suitable place (To be decided by Engr-in-charge) duly locking arrangement, cable glands etc and confirming the following and locking arrangement, complete all as specified and directed INCOMING (1) MCCB 63 AMP 4 P 25 kA, 415 Volts, 50 Hz thermal magnetic based with o/c, s/c protection & ROH - 01 nos (b) Copper bus bar for phase and neutral having 100 Amp rated capacity mounted over the PVC/Porcelain insulators duly enclosed into the busbar chamber with locking arrangements and having colour coded sleeves of R Y B and green colour. (c) Suitabel Insulated sheild -03 Nos and spreaders set of four - 02 nos
OUT GOING :(1) 40 amp MCB DP 10 ka with enclosure - 03 nos. (2) refixing of electric energy meter 03 Nos retrived from site after duly caliberation and including carrying out proper wiring from busbar to SPN MCB and MCB to KWH meter through single core 6 sqmm, FRLS multistranded copper conductor of proper colour code. (3) Multifunctional digital meter showing amp, volt, frequency etc.-01 (4) LED phase indicator-01 set. NOTE-Contractor should visit the site and to prepare panel as per size required to fit in below stair case complete all as specified and directed by Engr-in-charge
Supply and fix decorative wall light fitting including 10w LED lamp complete all as specified and directed by Engr-in-charge.
S&F SPN MCB 240V 50Hz 10KA confirming to IS 8828 of rating 40 to 63 Amp as per in repairs all as specified and directed.
S & F in repair/replacement of old existing sunken/terminal box of size 10x10cm, cocealed/surface mounted alongwith hylam sheet for fixing existing switches, sockets & regulators etc and making good disturbed surfaces of walls all as specified and directed.
S & F in repair/replacement of old existing sunken/terminal box of size 20x15cm, cocealed/surface mounted alongwith hylam sheet for fixing existing switches, sockets & regulators etc and making good disturbed surfaces of walls all as specified and directed.
S & F in repair/replacement of old existing sunken/terminal box of size 20x25cm, cocealed/surface mounted alongwith hylam sheet for fixing existing switches, sockets & regulators etc and making good disturbed surfaces of walls all as specified and directed.
JAVEED TRADERS
D.N.PATIL
INDIA ENGINEERS AND CONTRACTORS
M.K Enterprises
India enterprices
K A ELECTRIC CO
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .