| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹53.6 LAccepted-AOC | 1 | Accepted-AOC Being L-1 | |
| 2 | 2₹64.0 L+₹10.4 L (19.4%)Rejected-Finance 1 128 A SECOND FLOOR MOHAMMADPUR NEAR BHIKAJCAMA PLACE NEW DELHI 110066 | NEW DELHI | NEW DELHI | DELHI | 110066 | 2 | Rejected-Finance Being other than L-1 | |
| 3 | 3₹86.1 L+₹32.5 L (60.5%)Rejected-Finance III 6 7 2ND FLOOR ABOVE BANK OF BARODA GOPINATH BAZAR DELHI CANTT 110 010 | DELHI CANTT | NEW DELHI | DELHI | 110010 | 3 | Rejected-Finance Being other than L-1 |
Tender Value
₹59 L
EMD Value
₹1.1 L
Closing Date
22 Nov 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Col Sharath Ravindran CWE
HQ CWE (AF) Chakeri Pin-208008
PROVN OF LIFT IN P-45 AT 7AFH KANPUR
2022_MES_542185_4
CA NO.CWE(AF)/CHK/BR/T-17 OF 2022-23
Open Tender
Civil Works
Item Rate
180 days
GE (AF) B/R Chakeri
Please refer Tender documents.
7 documents required · 7 mandatory
₹1,000
GE (AF) B/R Chakeri
₹1.1 L
15 Dec 2022
3 Nov 2022
24 Nov 2022
3 Nov 2022
22 Nov 2022
10 Nov 2022
Amount
Demolition of RCC any description in any position not otherwise described including cutting reinforcement as required and removing the debris out of MD land complete all as specified and directed.
Excavation in over area not exceeding 1.5m deep and getting out in soft/loose soil complete all as specified and directed.
Excavation in over area exceeding 1.5 m and not exceeding 3.0 m deep and getting out in soft/loose soil complete all as specified and directed.
Returning filling in including spreading, leveling, watering and well ramming in layers not exceeding 25 CM complete all as specified and directed.
Removing excavated material not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 Mtr above the starting point complete.
M&L for PCC Type D-2 (1:4:8) (Using 40 mm graded stone aggregate) lean concrete as in foundation filling and mass concrete complete all as specified and directed.
M&L for brick work with fly ash bricks using old size bricks on plan not exc 6.0 mtr mean radius built in cement mortar 1:6 as in wall etc complete all as specified and directed.
M&L for RCC M-25 design mix (using 20mm graded stone aggregate) as in foundation including raft , footing, foundation beams and plinth beam complete all as specified and directed.
M&L for RCC M-25 design mix (using 20mm graded stone aggregate) as in columns, pillar, post ,piers, struts complete all as specified and directed.
M&L for RCC M-25 design mix (using 20mm graded stone aggregate) as in slab supported on walls, beams in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed.
M&L for TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
All as per item No 11 above, but 8 mm dia and over upto and including 10 mm dia as in stirrups, spacers and binders.
Use and waste of formwork (rough finished) to side of concrete foundation , footing, bases of column , side of beam and plinth beam complete all as specified and directed.
Use and waste of formwork to sides of columns, pillar, post ,piers, struts complete all as specified and directed.
Use and waste of formwork to side & soffits floor / roof beam, lintel, cantiliver , shelves, retaining wall etc complete all as specified and directed.
Use and waste of formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work (Horizontal or sloping) complete all as specified and directed.
M&L for rendering 5 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4, complete all as specified and directed.
M&L for applying two or more coat of 100% premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489-2004, Alkali & fungal resistance , dirt resistance exterior paint of required shade (company depot tinted) with silicon additive @ 1.43 litre/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm over new surfaces complete all as specified and directed.
M&L for preparation of newly plastered surfaces of wall and applying two coats of white wash complete all as specified and directed.
M&L for preparation of newly plastered surfaces of ceiling and applying two coats of white wash complete all as specified and directed.
M&L for preparation of new plastered surfaces of walls or ceilings and applying two coats of OBD over one coat of alkaline resistant primer complete all as specified and directed.
Demolition of PCC not exc. 15 cm thickness in floors, roofs or pavings and throwing debris at low lying area not exc. 1.0 km complete all as specified and directed
M&L for 75mm thick PCC Type C-2 (1:3:6) (Using 40 mm graded stone aggregate) as in sub base of flooring complete all as specified and directed.
M&L for industrial, heavy duty, virtrified tiles, scratch, stain & acid resistant, 600 x 600x 15 mm thick, MOH not less than 6, water absorption less than 0.5%, laid and jointed with adhesive, with minimum 3 mm spacer, as in floor as per manufacturer's instruction including 15 mm thick screed bed in CM (1:6) and jointed in neat cement slurry and pointed in white or coloured cement to match shade of tiles complete all as specified and directed.
M&L for vitrified ceramic tiles double charged 10 mm thick (square/rectangular) polished area of each tiles exceeding 0.42 sqm not exceeding 1.00 sqm in vertical surface etc set and jointed in neat cement slurry and pointed in white or coloured cement to match (dark as approved by GE) over and including 10 mm thick cement plaster as backing coat in CM (1:4) complete all as specified and directed.
Excavation in post holes (or similar holes ) each not exceeding 0.50 cum, getting out, returning filling in and ramming earth or broken rubble mixed with earth around, in layers not exc. 25 cm as in soft / loose soil / PCC complete all as specified and directed.
S&F rolled mild steel joist, channel, angle or tee sections, fixed independently, as in roof truss with connecting plates etc (cut to ordinary lengths i.e within 20mm of the length indicated) conforming to grade E-250 (Fe-410W quality) of any size shape complete all as specified and directed.
S&F steel work as stair case, baluster, hand rail etc conforming to Fe 410 Grade E-250 complete all as specified and directed.
S&F pre painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws complete as all specified & directed. Note : Colour & profile of sheet shall be approved by GE.
S&F pre painted galvalume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws complete as all specified & directed.
M&L for preparation of new or previously untreated steel surfaces and applying two coats of synthetic enamel paint exceeding 10 cm width or girth over a coat of red oxide primer complete all as specified and directed.
M&L for 10 mm thick cement plaster in cement mortar (1:4) mixed with and including water proofing compound @ 3% of by weight of cement over PCC padding over roof complete all as specified and directed.
M&L for providing roof treatment as under : - (a) Applying bitumenous primer @ 0.30 litres per sqm over cleaned and dry roof surface including parapet. (b) M&L for applying a coat of blown bitumen 85/25 grade @ 1.20 kg per sqm over priming coat of roof . (c) Supply and laying APP modified polyester reinforced water proofing membrane with minimum weight of 3.5 kg/sqm . The APP membrane shall be laid using torch-on application with minimum 10 cm side overlap and 15 cm end over lap. The APP membrane shall be fixed with termination bar and fasteners and end shall be properly sealed with sealent.
M&L for 10 mm thick plaster in CM (1:3) finished even & smooth w/o using extra cement on ceiling complete all as specified and directed.
S&F stainless steel (grade 304) as in hand rail, balustar, walkway etc complete all as specified and directed.
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 mtr in depth for laying of under ground electric cable and getting out in soft/loose soil complete all as specified and directed.
Supply & filling of sand cushioning (dry sand) free from impurities or vegetable grass in under ground cables for cable protection in layer of 8 cm deep before laying of cable and 15 cm depth after laying the cable, complete all as specified and directed. (NOTE : Punned thickness of sand layers shall be measured and paid .)
M&L for sub class B bricks old size well burnt, laid dry flat in trenches for protection of cable over LT/HT cable complete all as specified and directed.
Supply, laying & testing of XLPE insulated , screened, PVC bedded galvanised steel strip or wire armoured electric power cable heavy duty with aluminium conductor 1100 volts grade cross sectional 25 sqmm 4 core, laid in trenches/ducts /encased in GI pipe /fixed to pole complete all as specified and directed
S&F in trenches /fixed on pole / wall GI pipe of light grade,IS-1239 marked with required size of flat iron clamp duly painted with two coats of synthetic enamel paint over a coat of red oxide primer complete with bolts, nuts and washers of sizes 50 mm bore complete all as specified and directed.
M&L for earthing with galvanised cast iron earth plate of size 600 x 600 x 6 mm thick burred directly in ground not less than 2.25 Mtr below normal ground level, earth plate packed on all side with charcoal mixed wih salt to a thickness of 150 MM connected by GI earth strip of size 32 x 6mm thick soldered and rivetted to earth plate. GI earth strip will be protected by using 50 mm bore light grade GI pipe earth plate to steel tubular pole including flat iron clamp 25 x 3 mm including bolts nut and washers complete including watering GI pipe 20 mm dia light grade 2.5 Mtr long the earthing include PCC pit including necessary earth work and disposal of surplus soil to a distance not less than 50 Mtrs, chamber of PCC (1:4:8) type D 2 using 40 MM graded stone aggregate, coping shall be PCC(1:3:6) type C1 using 20 MM graded stone aggregate, RCC pit cover 50 MM thick (1:2:4) type B1 using 20 MM graded stone aggregate, reinforced with 8 MM MS bar at 80 MM C/C both way in lieu of CI pit cover and angle iron frame including flame funnel, wire mess, GI earth wire, 8 SWG under the earth and on the pole upto height of 1.5 Mtr shall be protected by 15 MM dia GI pipe (Light grade) GI pipe to be fixed with pole by means of 2 Nos flat iron clamp 25 x 3 MM size complete with bolts with nuts washers etc complete all as specified and shown in Electrical plate No 3 of MES SSR part -I 2009. (NOTE: 1. GI earth strip upto & including 7.5RM from the earth test point shall be deemed included in quoted unit rate. 2. GI earth strip beyond 7.5RM shall be measured and paid separately under respective items).
S&F sheet metal enclosure for MCB distribution board VTPN, 4 way double door type including with MCCB 4 Pole, 63 Amps, 36 KA fixed type as incomer with 200 amp rated bus bar and MCB 40 Amp TP, 10 KA, C Curve-01 Nos and 6 to 32 Amp SP, 10 KA C Curve-04 No complete all as specified and directed
M & L for one light , fan, call bell concealed point wiring on wall and surface on ceiling/roof with necessary fixing arrangements with PVC-FRLSH insulated and unsheathed copper multi-stranded conductor of size 1.5 Sqmm, 1100 volts grade drawn in and including rigid non metallic white / ivory PVC conduit medium grade ISI marked not less than 19 mm dia with all conduit accessories/ fittings such as junction boxes, bends, tee, elbow etc including anodized MS sunken boxes made out of MS sheet of thickness not less than 1.5 mm with earth dolly and Bakelite laminated sheet 3mm thick ISI marked for fixing of switches / sockets, fan regulators, wall mounting fittings, door bell & bulkhead etc with MS screw and cup washers including PVC-FRLSH insulated and unsheathed copper multi-stranded conductor of size 1.5 Sqmm, 1100 volts grade for continuous earthing including cutting the chases and making good the surface by cement mortar (1:3) and for matching / finishing of new surfaces either by means of plaster of paris/ Putty or distemper / colour wash with same existing colour surfaces complete all as specified and directed .
All as per item No-43 here-in-before but with 2.5 Sqmm PVC insulated unsheathed copper stranded conductor and earth wire with 2.5 Sqmm for one 5 in 15 Amp socket on independent board
S&F ceiling rose surface backelite 65x20 mm three terninal complete all as specified and directed.
S&F switch flush type single pole one way 5 Amps, 240 volts, white finish complete all as specified and directed.
S&F switch socket combination outlet 5 pin, 5/15 Amps flush type white finish complete all as specified and directed.
S&F fluorescent tube light fitting complete efficient LED batten and integrated type single tube 20 wat, 4ft long white complete with LED rod, LED driver and LED three core flexible cord in min size 0.5 sqmm and preconnector etc including provision of hanging and wall mounting complete all as directed"
(a) Speed : 1.0M/Sec.
(b) Drive : VVVF (Variable voltage variable frequency) drive.
(c) Operation : Full collective operation
(d) Type of machine : PM Gearless (Located in shaft on top of guide rails) Machine room less (MRL)
(e) Stops and Opening : 2 stops with (on 1 floor thru type opening and same side opening on 2 nd floor)
(f) Floor Designation : G+1
(g) Car rise : 4.5 M
(h) Car door finish : Stainless steel #4 (Hairline finish)
(j) Car Entrance : Telescopic 2 speed doors
(k) Car Size : About 1000mm wide x 2400mm deep x 2200mm High
(l) Door opening : About 900mm Wide x 2000mm High
(m) Hoist way dimensions : 1850mm wide x 2800mm deep
(n) Elevator pit depth : 1350mm
(o) Over head : 4200mm
(p) Mains supply : 415v, 3 phase, 50 Hz.
(q) Flooring : Vinyl Tiles
(r) Signals : Indicator for all landings, floor position indicator for all landings.
(s) Special Features : Anti-nuisance Car Call Protection, Independent Service (for Duplex only), Overload Device, Nudging, Emergency Firemen's Service, Emergency car Light Unit, Infrared Curtain door protection, Door time protection, Emergency Alarm Button, Extra Door time of lobby & Parking, Door open/Close Button, Manual rescue operation, Belt inspection drive 7 Auto fan cut off.
Manning and Operation of Hospital passenger cum stretcher elevator/lift of capacity 15 passenger (1020 Kgs), at building number P-45 through OEM trained technician for round the clock duties responsible for attending/ monitoring the breakdown, operation of lift and including periodical maintenance /checking of all installed components and testing as per OEM and as specified complete in three shifts i.e 0600 Hrs to 1400 Hrs , 1400 Hrs to 2200 Hrs , 2200 Hrs to 0600 Hrs including sunday and holidays by deploying 03 Persons (one person in each shift ) skilled OEM trained technician having ITI certificate of relavant field or minimum 5 years experence in this trade all as specified and directed. The technician shall be competent in following field:- (a) Trouble shooting, repairs and maintenance of lift control panels. (b) Uploading and downloading of ladder logic based programs. (c) Manual/ remote operation of lift and act as assistant for rescue in case of any failure of lift. (d) Technician shall be responsible for all short of periodical servicing required for the system like as cabin, doors control panel, drives, pulley, chain, gears system, electric motor, sensors etc and maintain proper log sheets of the work carried out. Note :- (i) T&P required such as insulated cutting plier , insulated Screw driver , megger , earth tester , Ladder , Crimping machine suitable to 6 sqmm to 300 sqmm cable , hand torch, Emergency light , test lamp, Double ended spanner set, adjustable wrench, LN Key, gloves suitable for 33/11 KV ,First Aid box , etc, shall be provided by the contractor with out any extra cost to the Government.
Note (Contd.....) :- (ii) Duty staff will maintain the installation, machinery, control panels and the premises clean and tidy and will report break downs or any defects immediately to the Engineer-in-charge / concern JE. (iii) One MOBILE PHONE for the manning staff will be provided by the contractor at the installation to keep liaison / communication with MES staff / Users. (iv) In case of trade man employed at lift found absent from duty fine of Rs. 1000.00 per shift will be recovered and will be not paid for that shift. (v) The firm /Contractor shall be soley and fully responsible to his representatives/staff for any accident /damage during maintenance and operation . The department will not entertain any claim , compensation etc. on this account and shall have no liability in this regard. (vi) The contractor shall enter a MOU with OEMs for the provision of the lift and further maintenance. (vii) Attendance in attendance register shall be marked twice during the duty hrs. Firstly at the start of duty hrs and secondly at the completion of duty hrs before leaving the assigned duty place. (viii) Payment to the contractor shall be made as per attendance of workmen, registered in the attendance register. (ix) Monthly printout of attendance, duly verified by contractor and Engineer-in-Charge, shall be kept in record for payment.
Note (Contd.....) :- (x) Contractor shall regularly monitor and verify the attendance being marked in the attendance register and bring any absence or change of workmen to the notice of Engr-in-Charge in writing immediately. (xi) Employment of workmen and payment thereof shall be regulated by EPF & MP Act 1952 as amended time to time by GOI. (xii) PAYMENT OF WORKERS:- Contractor shall arrange to open bank account in any Nationalised Bank of all labour/ workers employed for execution of work and wages paid to workers through bank transaction i.e. NEFT, cheque etc. The proof of the same shall be produced to the Engr-in-Charge for verification. (xiii) UNIFORM / CLOTHING:- The duty staff/ operator should be in proper uniform, uniform to be provided by contractor after getting approval of GE/EIC. (xiv) Contractor will carryout routine maintenance of the lift as per the manufacturere norms or instructions give by GE/ EIC. (xv) Minimum wages:- While dropping the tender for the subject work it is advised to the contractor that the minimum wages for the technicians must not be lower than the Govt rates under the minimum wages act1948 IX Vol). During execution also it must be ensured that contractor will provide minimum wages prevailing at that time to the individulas employed and contractor quoted rate shall be deemed to be inclusive of the same. (xvi) Any minor/ major repair/ replacement in the plant/ lift if required will be carried out by the contractor without any extra payment within the defect liability period.
M/s Dhapola Elevator and Engineering
MB Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .