Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.4 CrAdmitted-Finance | ₹6.4 Cr | L1 | Admitted-Finance |
| 2 | L2₹6.6 Cr+₹17.7 L (2.75%)Admitted-Finance | ₹6.6 Cr+₹17.7 L (2.75%) | L2 | Admitted-Finance |
| 3 | L3₹6.8 Cr+₹40.0 L (6.21%)Admitted-Finance | ₹6.8 Cr+₹40.0 L (6.21%) | L3 | Admitted-Finance |
| Sl No | Description | Qty | Unit | MARUTHI ENGINEERING CONTRACTORS L2 | SAHARA INFRASTRUCTURES L3 | JAI BABA LAL ENTERPRISES L1 |
|---|---|---|---|---|---|---|
| 1.00 | (A) AUGMENTATION OF WATER SUPPLY SCHEME BHUPNERGARH UNDER JJM: RAPID SAND FILTERATION PLANT (Capacity 5000 GPH) Design, drawing,fabrication,construction, instalation and commissioning of 5000 GPH capacity Rapid Sand Gravity Filter Plant under (Turn Key bases) using stainless steel grade SS 304 all welded wedge wire screen pipe as per IS 8110 internal part of screen pipe lateral should be duly assembled with HDPE/PVC base pipe duly perforated covered & screen should not have any circumferential or longitudinal joints in screen section. The screen opening should be 200 to 300 microns to faclitate the direct retention of filter media and must be designed to suit filtrate rate upto 4.8m^3/hr/m^2 of bed area. The under-drain system should be equipped separate air back wash system for each lateral. The filter bed should have central and side channel in RCC/MS for smooth traveling of backwash water/The Water Treatment Plant consisting of static mixture, Flocculation of tank, chemical dosing system for PAC/Alum, multi-grade gravity filter with best quality filter charging materials including all fittings like valve and other special fittings, filter feed pump, Mcc, cabling, cost of providing and applying epoxy paint on the exposed equipment , including necessary testing and commissioning and trial run for 1 (one) year. | 1 | Job | 55,25,000 ₹55,25,000 | 55,40,000 ₹55,40,000 | 54,50,000 ₹54,50,000 Lowest |
| 2.00 | Design, Drawing, Construction and commissioning of treated RCC clear water storage tank of 10000 Gallons capcity in M-25 concrete mix (Spherical Shape) Incl all type of carriages with leads and lifts (Clear storage Ht. 3.50 Mtr.) & provision for manhole covering, Steel stairs, possible measuring gauge, inlet, outlet , overflow and wash out pipes (100 mm dia) complete Job have to be executed as CPHEEO norms/BIS Specifications on turn key basis. | 1 | Job | 6,70,000 ₹6,70,000 | 6,95,000 ₹6,95,000 | 6,55,000 ₹6,55,000 Lowest |
| 3.00 | Pump Room Building (Size 7.95 x 3.70 x 3.65 M) Design, drawing and construction of Pump Room Building covering design for permissible seismic effects (size 7.95 m x 3.70 m , height 3.65 mtr) with mass concrete in foundation, brick walls and RCC roofings along with insulated floor mating, painting & writings, electric fittings, steel girders, drainage, Plumbing, sanitation and water supply including attached toilet with septic tank and soakage pit. | 1 | No. | 13,50,000 ₹13,50,000 | 13,30,000 ₹13,30,000 Lowest | 13,30,000 ₹13,30,000 Lowest |
| 4.00Pipe Works: Providing, Laying & fitting of G.I pipes( of any make as per Bureau of Indian Standard) for Rising main and Distribution system including clearance of site, earth work in excavation as per perscribed trenches and available classfiications of soil complete with cost & fixing of all required fittings / specials/ Gate Valves/Sluivce Valves/ Check Valves (ISI marked branded make) along with allied accessories, mainfolds, , fabrication /welding of joints weherever required, cutting/ crossing of roads / berm surfaces, lanes and drains including restoration of same after laying of pipes .Refilling of earth back in trenches including disposal of surplus earth/mulba to designated place and carriages of all sorts complete with testing & commissioning (complete Job/rm). | ||||||
| 5.00 | GI pipe 65mm dia (Medium) (trench size 0.60 x 0.60) | 5,450 | Mtr. | 980 ₹53,41,000 | 984 ₹53,62,800 | 967 ₹52,70,150 Lowest |
| 6.00 | Providing/Installation of household connections | 90 | Nos. | 5,100 ₹4,59,000 | 5,300 ₹4,77,000 | 5,000 ₹4,50,000 Lowest |
| 7.00 | Interconnection of Rising Main and Distribution Systen incl. fabrication works and valve pits | 1 | Job | 2,15,000 ₹2,15,000 | 2,05,000 ₹2,05,000 Lowest | 2,05,000 ₹2,05,000 Lowest |
| 8.00 | Supply , installation. testing and commissioning of Flow Metering System (ISI Marked with reputed branded for make to be approved by Engineer -in -Incharge ) | 1 | No. | 1,05,000 ₹1,05,000 | 1,07,000 ₹1,07,000 | 1,00,000 ₹1,00,000 Lowest |
| 9.00 | Storage Tanks (Cap 5000 Gallons) Design , Drawing , construction and comissioning of RCC 5000 Glns capacity Sump Tank/GSR/ collection Tank spherical shape (ht. 3.00 mtr excl. free board) with dome shaped roof covering with provision & fixing of manhove covering, Steel Stairs, measuring gauge including inlet / outlet G.I. pipes embeded in cement concrete complete in all respects. | 3 | Nos. | 5,29,000 ₹15,87,000 | 5,30,000 ₹15,90,000 | 5,25,000 ₹15,75,000 Lowest |
| 10.00 | Mechanical Works: Providing, Installation, testing and commissioning of 02 Nos. HC pumps of parameters 5000 GPH x 250 mtr head (of any make as per Bureau of Indian Standard ) preferbly low speed prime movers with automatic control panel and with provision of standby manual starter , the delivery and suction should be of MS pipe of standard make , 01 No. voltage stablizer 150 KVA (of any make as per Bureau of Indian Standard) alongwith and creation/erection 100 KVA (Level 2) eletcric sub-staion from existing HT source to proposed site , the electric cables/ items should be of any make as per Bureau of Indian Standard with allied works at proposed site | 1 | Job | 31,75,000 ₹31,75,000 | 31,50,000 ₹31,50,000 | 29,50,000 ₹29,50,000 Lowest |
Tender Value
₹5.4 Cr
Closing Date
12 Mar 2021, 4:00 pmClosed
Executive Engineer Jal Shakti, PHE division Samba
Executive Engineer Jal Shakti, PHE Division Samba District Offices Complex Nandni Hills Samba
Please refer BOQ
2021_PHE_118937_1
PHES/175 of 2020-21
Open Tender
Civil Works - Water Works
Item Rate
180 days
Bhupnergarh, Sarna Patyari and Tund Sarain, Samba
Please refer e-Nit and SBD
8 documents required · 8 mandatory
₹6,000
Executive Engineer Jal Shakti, PHE Division Samba
Exempted
17 Mar 2021
3 Mar 2021
13 Mar 2021
3 Mar 2021
12 Mar 2021
3 Mar 2021
Amount
(A) AUGMENTATION OF WATER SUPPLY SCHEME BHUPNERGARH UNDER JJM: RAPID SAND FILTERATION PLANT (Capacity 5000 GPH) Design, drawing,fabrication,construction, instalation and commissioning of 5000 GPH capacity Rapid Sand Gravity Filter Plant under (Turn Key bases) using stainless steel grade SS 304 all welded wedge wire screen pipe as per IS 8110 internal part of screen pipe lateral should be duly assembled with HDPE/PVC base pipe duly perforated covered & screen should not have any circumferential or longitudinal joints in screen section. The screen opening should be 200 to 300 microns to faclitate the direct retention of filter media and must be designed to suit filtrate rate upto 4.8m^3/hr/m^2 of bed area. The under-drain system should be equipped separate air back wash system for each lateral. The filter bed should have central and side channel in RCC/MS for smooth traveling of backwash water/The Water Treatment Plant consisting of static mixture, Flocculation of tank, chemical dosing system for PAC/Alum, multi-grade gravity filter with best quality filter charging materials including all fittings like valve and other special fittings, filter feed pump, Mcc, cabling, cost of providing and applying epoxy paint on the exposed equipment , including necessary testing and commissioning and trial run for 1 (one) year.
Design, Drawing, Construction and commissioning of treated RCC clear water storage tank of 10000 Gallons capcity in M-25 concrete mix (Spherical Shape) Incl all type of carriages with leads and lifts (Clear storage Ht. 3.50 Mtr.) & provision for manhole covering, Steel stairs, possible measuring gauge, inlet, outlet , overflow and wash out pipes (100 mm dia) complete Job have to be executed as CPHEEO norms/BIS Specifications on turn key basis.
Pump Room Building (Size 7.95 x 3.70 x 3.65 M) Design, drawing and construction of Pump Room Building covering design for permissible seismic effects (size 7.95 m x 3.70 m , height 3.65 mtr) with mass concrete in foundation, brick walls and RCC roofings along with insulated floor mating, painting & writings, electric fittings, steel girders, drainage, Plumbing, sanitation and water supply including attached toilet with septic tank and soakage pit.
Pipe Works: Providing, Laying & fitting of G.I pipes( of any make as per Bureau of Indian Standard) for Rising main and Distribution system including clearance of site, earth work in excavation as per perscribed trenches and available classfiications of soil complete with cost & fixing of all required fittings / specials/ Gate Valves/Sluivce Valves/ Check Valves (ISI marked branded make) along with allied accessories, mainfolds, , fabrication /welding of joints weherever required, cutting/ crossing of roads / berm surfaces, lanes and drains including restoration of same after laying of pipes .Refilling of earth back in trenches including disposal of surplus earth/mulba to designated place and carriages of all sorts complete with testing & commissioning (complete Job/rm).
GI pipe 65mm dia (Medium) (trench size 0.60 x 0.60)
Providing/Installation of household connections
Interconnection of Rising Main and Distribution Systen incl. fabrication works and valve pits
Supply , installation. testing and commissioning of Flow Metering System (ISI Marked with reputed branded for make to be approved by Engineer -in -Incharge )
Storage Tanks (Cap 5000 Gallons) Design , Drawing , construction and comissioning of RCC 5000 Glns capacity Sump Tank/GSR/ collection Tank spherical shape (ht. 3.00 mtr excl. free board) with dome shaped roof covering with provision & fixing of manhove covering, Steel Stairs, measuring gauge including inlet / outlet G.I. pipes embeded in cement concrete complete in all respects.
Mechanical Works: Providing, Installation, testing and commissioning of 02 Nos. HC pumps of parameters 5000 GPH x 250 mtr head (of any make as per Bureau of Indian Standard ) preferbly low speed prime movers with automatic control panel and with provision of standby manual starter , the delivery and suction should be of MS pipe of standard make , 01 No. voltage stablizer 150 KVA (of any make as per Bureau of Indian Standard) alongwith and creation/erection 100 KVA (Level 2) eletcric sub-staion from existing HT source to proposed site , the electric cables/ items should be of any make as per Bureau of Indian Standard with allied works at proposed site
Fencing/Compound Wall
Design, drawing, providing and construction of Chain link fencing all around the Civil Structures (av. Area 85.00 sqm).
Design, drawing, providing and construction of Compound wall (covering seismic effects) around the pheriphery of the station (avg. covering area 600 sqm), Development of Pumping station inclusive drainage of overflowing water & catchment, outer Illumination by Halogen Lights (minium 4 to 6 Nos), erection of sign board & levelling of ground / land scaping and plantings with provision of Rain Water Conservation depending on site conditions at Spots.
(B) RETROFITTING OF EXISTING WATER SUPPLY SCHEME SARNA PATYARI UNDER JJM
RAPID SAND FILTERATION PLANT (Capacity 5000 GPH): Design, drawing,fabrication,construction, instalation and commissioning of 5000 GPH capacity Rapid Sand Gravity Filter Plant under (Turn Key bases) using stainless steel grade SS 304 all welded wedge wire screen pipe as per IS 8110 internal part of screen pipe lateral should be duly assembled with HDPE/PVC base pipe duly perforated covered & screen should not have any circumferential or longitudinal joints in screen section. The screen opening should be 200 to 300 microns to faclitate the direct retention of filter media and must be designed to suit filtrate rate upto 4.8m^3/hr/m^2 of bed area. The under-drain system should be equipped separate air back wash system for each lateral. The filter bed should have central and side channel in RCC/MS for smooth traveling of backwash water/The Water Treatment Plant consisting of static mixture, Flocculation of tank, chemical dosing system for PAC/Alum, multi-grade gravity filter with best quality filter charging materials including all fittings like valve and other special fittings, filter feed pump, Mcc, cabling, cost of providing and applying epoxy paint on the exposed equipment , including necessary testing and commissioning and trial run for 1 (one) year.
Design, Drawing, Construction and commissioning of treated RCC clear water storage tank of 10000 Gallons capcity in M-25 concrete mix (Spherical Shape) Incl all type of carriages with leads and lifts (Clear storage Ht. 3.50 Mtr.) & provision for manhole covering, Steel stairs, possible measuring gauge, inlet, outlet , overflow and wash out pipes (100 mm dia) complete Job have to be executed as CPHEEO norms/BIS Specifications on turn key basis.
CHECK DAM AND INTAKE STRUCTURE( Length 20 Mtr):Design, Drawing, Construction of RCC Check Dam across the breadth of nallah with foundation below scourcing depth and along with wing walls on the both ends and protection work along banks upstream and downdstream of the Check Dam along with construction of intake structure with sufficient quantity or storage of underground inflow of water.
Bore-Well (Discharge 3500 GPH): Deep Drilling of 200 mm dia bore-well by using ODEX/ Drilling Method having minimum safe discharge of 3500 GPH upto required depth (minimum 130 BGL mtr and further technically feasible depth) for acquiring desired discharge including lowering of 200 mm dia MS casing pipes and providing / fixing of casing drive shoe including cost of 200 mm dia ERW M.S. casing pipes. Development of bore by air compressor of adequate capacity till the clear portable water free from sand and other impurities along with clearance of site by way of bush cutting, making approach road , shiting of machinery, tools and tackle and all material prepration of site ,Stablization and testing of bore-well by way of pumping for maximum four days using verticl turbine pump / submersible pump set till the clear portable drinking water is achived including the yield test .Fabrication, Providing and fitting of steel supporting clamps.
Pump Room Building (Size 7.95 x 3.70 x 3.65 M): Design, drawing and construction of Pump Room Building covering design for permissible seismic effects (size 7.95 m x 3.70 m , height 3.65 mtr) with mass concrete in foundation, brick walls and RCC roofings along with insulated floor mating, painting & writings, electric fittings, steel girders, drainage, Plumbing, sanitation and water supply
Pipe Works: Providing, Laying & fitting of G.I pipes( of any make as per Bureau of Indian Standard) for Rising main and Distribution system including clearance of site, earth work in excavation as per perscribed trenches and available classfiications of soil complete with cost & fixing of all required fittings / specials/ Gate Valves/Sluivce Valves/ Check Valves (ISI marked branded make) along with allied accessories, mainfolds, , fabrication /welding of joints weherever required, cutting/ crossing of roads / berm surfaces, lanes and drains including restoration of same after laying of pipes .Refilling of earth back in trenches including disposal of surplus earth/mulba to designated place and carriages of all sorts complete with testing & commissioning (complete Job/rm).
GI pipe 80mm dia (Light) (trench size 0.80 x 0.60)
GI pipe 65mm dia (trench size 0.60 x 0.60)
GI pipe 50mm dia (trench size 0.60 x 0.50)
GI pipe 40mm dia (trench size 0.50 x 0.40)
GI pipe 15mm dia (trench size 0.30 x 0.30)
Interconnection of Rising Main and Distribution Systen incl. fabrication works and valve pits
Providing/Installation of household connections
Supply , installation. testing and commissioning of Flow Metering System (ISI Marked with reputed branded for make to be approved by Engineer -in -Incharge)
Storage Tanks (Cap 10000 Gallons): Design , Drawing , construction and comissioning of RCC 10,000 Glns capacity Sump Tank/GSR/ collection Tank spherical shape (ht. 3.50 mtr excl. free board) with dome shaped roof covering , provision & fixing of manhole covering, Steel Stairs, measuring gauge including inlet ,outlet, overflow and wash out G.I. pipes (80 mm dia) embeded in cement concrete along with allied works complete in all respects with M-25 concrete mix
Storage Tanks (Cap 5000 Gallons) Design , Drawing , construction and comissioning of RCC 5000 Glns capacity Sump Tank/GSR/ collection Tank spherical shape (ht. 3.00 mtr excl. free board) with dome shaped roof covering with provision & fixing of manhole covering, Steel Stairs, measuring gauge including inlet / outlet G.I. pipes embeded in cement concrete complete in all respects with M-25 concrete mix
Mechanical Works:
Providing, Installation, testing and commissioning of 02 Nos. HC pumps of parameters 5000 GPH x 200 mtr head (of any make as per Bureau of Indian Standard) preferbly low speed prime movers with automatic control panel and provision of manual starter , 01 No. voltage stablizer 100 KVA (of any make as per BIS) alongwith and creation/erection 100 KVA (Level 2) eletcric sub-staion from existing HT source to proposed site , 02 No. submersibler pump set of parameters 3000 GPH x 80 mtr head ( 01 No. working + 01 No. standby) with automatic control panel and provision of standby manual starter at existing dug-well Sarna .The pipes used for suction/ delivery and column pipes should be of MS pipes of standard make of suitable dia , electric cables / items should be of of any make as per BIS.Complete job with allied works at proposed site of Filtration Plant Sarna.
Providing, Installation, testing and commissioning of submersibler pump set of parameters 3000 GPH x 150 mtr head ( 01No. working + 01 No. standby) (of any make as per Bureau of Indian Standard) with automatic control panel and provision of standby manual starter at proposed tube- well site, 01 No. voltage stablizer 100 KVA (ISI Marked make) alongwith and creation/erection 100 KVA (Level 2) eletcric sub-staion from existing HT source to proposed site The column pipes should be of MS pipes of standard make of suitable dia with proper flanging to 10 feet lengths , electric cables / items should be of any make as per Bureau of Indian Standard .Complete job with allied works at proposed site of Filtration Plant site
Chain Link Fencing:Design, drawing, providing and construction of Chain link fencing all around the Civil Structures (av. Area 85.00 sqm).
Compound Wall: Design, drawing, providing and construction of Compound wall (covering seismic effects) around the pheriphery of the station (avg. covering area 600 sqm), Development of Pumping station inclusive drainage of overflowing water & catchment, outer Illumination by Halogen Lights (minium 4 to 6 Nos), erection of sign board & levelling of ground / land scaping and plantings with provision of Rain Water Conservation depending on site conditions at Spots.
Provision for ropeway crossing
(c) RETROFITTING OF EXISTING WATER SUPPLY SCHEME TUND SARAIN UNDER JJM
RAPID SAND FILTERATION PLANT (Capacity 5000 GPH) Design, drawing,fabrication,construction, instalation and commissioning of 5000 GPH capacity Rapid Sand Gravity Filter Plant under (Turn Key bases) using stainless steel grade SS 304 all welded wedge wire screen pipe as per IS 8110 internal part of screen pipe lateral should be duly assembled with HDPE/PVC base pipe duly perforated covered & screen should not have any circumferential or longitudinal joints in screen section. The screen opening should be 200 to 300 microns to faclitate the direct retention of filter media and must be designed to suit filtrate rate upto 4.8m^3/hr/m^2 of bed area. The under-drain system should be equipped separate air back wash system for each lateral. The filter bed should have central and side channel in RCC/MS for smooth traveling of backwash water/The Water Treatment Plant consisting of static mixture, Flocculation of tank, chemical dosing system for PAC/Alum, multi-grade gravity filter with best quality filter charging materials including all fittings like valve and other special fittings, filter feed pump, Mcc, cabling, cost of providing and applying epoxy paint on the exposed equipment , including necessary testing and commissioning and trial run for (one) year.
Design, Drawing, Construction and commissioning of treated RCC clear water storage tank of 10000 Gallons capcity in M-25 concrete mix (Spherical Shape) Incl all type of carriages with leads and lifts (Clear storage Ht. 3.50 Mtr.) & provision for manhole covering, Steel stairs, possible measuring gauge, inlet, outlet , overflow and wash out pipes (100 mm dia) complete Job have to be executed as CPHEEO norms/BIS Specifications on turn key basis.
Bore-Well (Discharge 3500 GPH)Deep Drilling of 200 mm dia bore-well by using ODEX/ Drilling Method having minimum safe discharge of 3500 GPH upto required depth (minimum 130 BGL mtr and further technically feasible depth) for acquiring desired discharge including lowering of 200 mm dia MS casing pipes and providing / fixing of casing drive shoe including cost of 200 mm dia ERW M.S. casing pipes. Development of bore by air compressor of adequate capacity till the clear portable water free from sand and other impurities along with clearance of site by way of bush cutting, making approach road , shiting of machinery, tools and tackle and all material prepration of site ,Stablization and testing of bore-well by way of pumping for maximum four days using verticl turbine pump / submersible pump set till the clear portable drinking water is achived including the yield test .Fabrication, Providing and fitting of steel supporting clamps.
Pump Room Building (Size 7.95 x 3.70 x 3.65 M) Design, drawing and construction of Pump Room Building covering design for permissible seismic effects (size 7.95 m x 3.70 m , height 3.65 mtr) with mass concrete in foundation, brick walls and RCC roofings along with insulated floor mating, painting & writings, electric fittings, steel girders, drainage, Plumbing, sanitation and water supply
Storage Tanks (Capacity 10000 Gallons) Design , Drawing , construction and comissioning of RCC 10,000 Glns capacity Sump Tank/GSR/ collection Tank spherical shape (ht. 3.50 mtr excl. free board) with dome shaped roof covering , provision & fixing of manhole covering, Steel Stairs, measuring gauge including inlet ,outlet, overflow and wash out G.I. pipes (80 mm dia) embeded in cement concrete along with allied works complete in all respects with M-25 concrete mix
Pipe works :Providing, Laying & fitting of G.I pipes( of any make as per Bureau of Indian Standard) for Rising main and Distribution system including clearance of site, earth work in excavation as per perscribed trenches and available classfiications of soil complete with cost & fixing of all required fittings / specials/ Gate Valves/Sluivce Valves/ Check Valves (ISI marked branded make) along with allied accessories, mainfolds, , fabrication /welding of joints weherever required, cutting/ crossing of roads / berm surfaces, lanes and drains including restoration of same after laying of pipes .Refilling of earth back in trenches including disposal of surplus earth/mulba to designated place and carriages of all sorts complete with testing & commissioning (complete Job/rm).
GI pipe 80mm dia (Medium) (trench size 0.80 x 0.60)
GI pipe 65mm dia (trench size 0.60 x 0.60)
GI pipe 40mm dia (trench size 0.45 x 0.45)
Interconnection of Rising Main and Distribution Systen incl. fabrication works and valve pits
Providing/Installation of household connections
Supply , installation. testing and commissioning of Flow Metering System (ISI Marked with reputed branded for make to be approved by Engineer -in -Incharge )
Mechanical Works:Providing, Installation, testing and commissioning of 01 No. HC pumps of parameter 3000 GPH x 150 mtr head (of any make as per Bureau of Indian Standard) preferbly low speed prime movers with automatic control panel for 02 Nos. HC Sets (01 No. New and 01 No. Existing) and with provision of standby manual starter , the delivery and suction should be of MS pipe of standard make 02 Nos. mono submersible pump sets ( 01 No. to be connected with new HC pump set and 01 No. with existing HC pump set ) of parameters 3000 GPH x 16 mtr head with control panels and with provision of standby manual starter suitable dia , 02 Nos. submersible pump sets ( 01 No. working + 01 No. standby) of parameters 3000 GPH x 150 mtr head with fully automatic control panel with provision of standby manual starter. The column pipes of suitable dia will be MS pipes of standard make with proper flanging at 10 feet ,01 No. voltage stablizer 150 KVA (of any make as per Bureau of Indian Standard) alongwith and creation/erection 100 KVA (Level 2) eletcric sub-staion from existing HT source to proposed site , the electric cables/ items should be of any make as per Bureau of Indian Standard complete with allied works at proposed site .
Chain Link Fencing: Design, drawing, providing and construction of Chain link fencing all around the Civil Structures (av. Area 85.00 sqm).
Compound Wall: Design, drawing, providing and construction of Compound wall (covering seismic effects) around the pheriphery of the station (covering area 600 sqm), Development of Pumping station inclusive drainage of overflowing water & catchment, outer Illumination by Halogen Lights (minium 4 to 6 Nos), erection of sign board & levelling of ground / land scaping and plantings with provision of Rain Water Conservation depending on site conditions at Spots.
MARUTHI ENGINEERING CONTRACTORS
SAHARA INFRASTRUCTURES
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.85 MB
BOQ_228337.xls
BOQ • 0.31 MB
SBDBhupnergarh.pdf
Tender Documents • 2.59 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .