| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹24.4 LAccepted-AOC | 1 | Accepted-AOC Lowest bidder | |
| 2 | 2₹26.9 L+₹2.0 L (8.19%)Rejected-Finance 64 SHAHEED UDHAM SINGH MARKET NEAR OLD BUS STAND BATHINDA 151001 PB | BATHINDA | BATHINDA | PUNJAB | 151001 | 2 | Rejected-Finance Not lowest bidder | |
| 3 | 3₹27.4 L+₹2.6 L (10.3%)Rejected-Finance H NO 17036 9 STREET NO 5 A AGGARWAL COLONY BATHINDA PB 151001 | BATHINDA | BATHINDA | PUNJAB | 151001 | 3 | Rejected-Finance Not lowest bidder | |
| 4 | 4₹27.5 L+₹2.6 L (10.4%)Rejected-Finance | 4 | Rejected-Finance Not lowest bidder | |
| 5 | 5₹27.6 L+₹2.8 L (11.2%)Rejected-Finance 18969 A 1 SHRI GURU TEG BAHADUR NAGAR BIBIWALA ROAD STREET NO 15 BATHINDA 151001 | BATHINDA | BATHINDA | PUNJAB | 151001 | 5 | Rejected-Finance Not lowest bidder |
Tender Value
Refer Docs
EMD Value
₹58,600
Closing Date
23 Dec 2020, 6:00 pmClosed
CWE Bathinda
HQ CWE BATHINDA BATHINDA MIL STATION 151004
SPECIAL REPAIRS TO BLDG NO P-251 OR LIVING OF GARH RIF UNDER GE (SOUTH) BATHINDA AT BATHINDA MIL STN
2020_MES_386299_2
CA NO CWE BTD 60 2020 21
Open Tender
Civil Works
Item Rate
180 days
Bathinda Mil Station
AS PER NIT
7 documents required · 7 mandatory
₹500
GE South Bathinda
₹58,600
Yes
4 Jan 2021
25 Nov 2020
25 Dec 2020
25 Nov 2020
23 Dec 2020
4 Dec 2020
Amount
Taking down chowkats or frames with shutters (without taking off shutters from the frames) area not exc 1.5 Sqm each and removing from site including cutting holes for removal of hold fast complete.
Taking down chowkats or frames with shutters (without taking off shutters from the frames) area not exc 1.5 Sqm each and re-fixing the same opening.
S&F in repairs factory made solid FRP door frame of size 100mm x 60 mm with inner core of treated and seasoned rubber wood and outer core of average 2mm thick FRP with gel coat finish and with average weight of 4 Kg per RM all as directed.
S&F factory made FRP door shutter 30mm thick are to be made with 3mm FRP unsaturated polyester resin moulded to 3mm FRP laminate for forming hollow rails and styles suitably rebated and seasoned rubber wood are to be filled inside at required places for fixing of fitting cast monolithically with 5mm thick FRP laminate for panels with gel coat finish and with average weight of 8 Kg per Sqm all as per IS-14856-2000.
S&F stainless steel butt hinges, medium grade, size of hinge100mm.
S & F 150 mm long aluminium anodised, barrel tower bolts of extruded section.
S & F 125 mm aluminium handles, cast type, anodised.
Taking down chowkats or frames with shutters (without taking off shutters from the frame) exc 1.5 sqm but not exc 4 Sqm each and removing from site including cutting holes for removal of hold fast complete.
S & F factory made pressed steel frames for door with one or more rebates including necessary fixing lugs, lock strike plate, hinges etc, complete, all as specified of frame size 125 mm x 60mm & thickness of MS sheet shall not be less than 1.25 mm including making holes for fixing hold fast etc and making good the wall with plaster in cement mortar (1:6) complete.
All as per item No. 9 above but frame size 105 x 60 mm
All as per item No. 9 above but frame size 75 x 60 mm
M & L for PCC (1:3:6) type C-0 using 12.5 mm graded stone aggregate in filling in chowkats/ door frame or bed block of hold fast and the like including weathering, slightly rounded or chamfered angles and throating, as directed complete.
Taking down shutters of any description exceeding 1 Sqm and not exceeding 2 Sqm each and re-fixing in the same opening including easing and adjusting including renewal of unserviceable screws etc complete.
S & F 35mm thick factory made panelled shutter (two panel) plain framed with lock rail and panel of 12mm thick veneered particle board with commercial veneering on both faces conforming to IS-3097 exterior grade kiln seasoned and chemically pressure treated of second class hard wood rails and styles and the size of rail and style as per IS-1003 (Part I).
S & F factory made glazed and skeleton shutters 35mm thick using second class hard wood open rebated and prepared to receive glass, gauge etc (without sash bars), edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass etc; sizes of members of shutters as specified in SSR Part I, Section 8, Clause 8.24(a); all as specified complete.
S&F stainless steel wire cloth, 0.36 mm nominal dia of wire & average width of aperture 1.40mm and fixed with stainless steel wire staples complete.
S&F in repairs, stainless steel wire cloth, 0.36 mm nominal dia of wire & average width of aperture 1.40mm and fixed with stainless steel wire staples complete.
S & F 300 mm long MS ordinary rat tail rod pattern springs for doors including roller and roller plate complete.
All as per item No 18 above but fixed in repairs.
S&F mild steel sliding door bolts, plate type, stove enamelled black, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate and fixed, length of bolt 300 mm.
S&F mild steel barrel tower bolts, stove enamelled black, with bright bolt and fixed, length of bolt 200mm.
S & F 150 mm mild steel pressed handles, oval type, stove enamelled black.
S&F factory made steel windows with side hung shutters including box type hinges with steel handle, and steel peg stay, complete without glazing bars, dovetailed or welded including one shop coat painting all as directed.
S & F factory made steel windows with side hung shutters including box type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded including one shop coat painting including dismantling of old existing window as directed.
S&F aluminium powder coated ventilator including necessary rubber gasket for fixing glass panes etc complete all as shown on drawing No CEBT/SK-936 sheet No.1/1. (Note- Glass panes and wire mesh shall be measured and paid for separately).
S & F sheet glass, 4 mm thick ordinary quality and glazing with oil putty in square not exceeding 0.5 Sqm in each pane fixed with oil putty or wooden beads including Provn of glazing pins/spring clips wherever necessary complete.
S & F 5 mm thick figured glass, pin head type and glazing with oil putty in aluminium ventilator complete.
Hacking out old broken glass (any thickness, size, quality or description) from metal frame including punching or drilling out old glazing pins / spring clips size not exceeding 1.5 Sqm each pane complete.
S&F factory made 25 mm thick flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides including teak wood beading.
M & L for painting to new steel and iron surfaces of any description, over 10 cm in width or girth, not otherwise described with two coats of synthetic enamel paint over a coat of red oxide primer including preparation of surfaces.
M & L for painting to new wood and wood based surfaces of any description, over 10 cm in width or girth, not otherwise described with two coats of synthetic enamel paint over a coat of pink primer including preparation of surfaces.
Demolition of cement concrete (un-reinforced) of any description and in any position not otherwise specifically provided for.
Water proffing treatment to sunken slab and adjoining vertical surfaces as specified under:- (a) M&L Rendring 10MM thick in cement plaster (1:3) using coarse sand mixed with integral water proofing compount as per manufacturer instruction trowel even and smooth with steel trowel on sunken surfaces. (b) Applying first coat of chemical pidifin 2K (DR Fixit) on clered RCC Surfaces @ 0.86 KG/SQM (Minimum) as Recommended by Manufacturer. (c) Provide a layer of Glass fibre mesh of size 2.25MM X 2.25 (45GSM) over first coat of chemical pidifin 2K as per manufacturer Recommendation. (d) Applying second coat of chemical pidifin 2KB(DR Fixit) @ 0.86 KG/SQM (Minimum) over layer of glass fibre mesh of size 2.25MM x 2.25MM (45 GSM) as recommended by manufacturers.
Supply only liquid water proofing material, ISI marked.
M&L for PCC (1:5:10) type E2 using 40 mm graded stone aggregate as in filling of sunken floor including demolition of existing PCC.
M & L for 25 mm thick PCC (1:2:4) type B0 using 12.50 mm graded stone aggregate as in sunken floor all as specified.
M & L for 40 mm bore GI pipe, medium grade, ISI marked, as in spout pipe including removal of existing one.
Demolition of brick tiles or terracing tiles, single layer on roofs including removing the demolished material exceeding 1 km and not exceeding 2 km away from site and disposal off in low lying area as directed.
Demolition of mud in roof, any thickness including plastering and leaping (where full thickness recovered or only a part there of) including removing the demolished material not exceeding 200 m away from site and disposal off in low lying area complete.
M&L for water proofing treatment over RCC slab by applying oil bound bituminous primer @ 0.30 kg/Sqm and providing and laying 3 mm thick APP modified water proofing memberane weighing not less than 3.50 kg/sqm, reinforced with non woven polyester reinforcement matt weighing not less than 160 gm/Sqm polyester core, having soften point not less than 150°C, longitudinal tensile strength not less than 650 N/ 5 cm, tearing strength of 180 N, torch application, side overlap 75 mm and end overlap 100 mm and tucked into the chases including ponding test all as specified and directed.
M&L for wire brushing and cleaning top surfaces of roof slabs etc, including washing the roof surface with water and making the surface free from mud and previous treatment, making surface good to receive further treatment etc complete all as specified.
M&L for 15 mm thick screed bed or bedding layer in cement mortar (1:3) on roof surfaces parapet or vertical beam surface (horizental or vertical) finishing the surfaces even and fair complete all as specified. (Note :- Course sand (Toka sand) shall only be used in screed bed/plastering.)
M&L for Lime concrete in lime mortar ratio (1:3) using 40 mm graded brick aggregate, laid to slope as directed by Engineer in charge over RCC roofs as padding complete alll as specified. Note: Minimum thickness of lime concrete at lower end shall not be less than 50mm.
M&L for 20- 22 mm thick factory made PCC tiles of size 250mm x 250mm with grey cement and no pigment , bedded in cement mortar (1:4) 15 mm thick and joints grouted flush in CM (1:3) mixed with @ 5% of crude oil by weight of cement complete all as specified.
M&L for PCC (1:2:4) type B-0 using 12.5 mm graded stone aggregate mixed with liquid water proofing material as in benching, kerbs, mud stops, along side walls adjoining to roofs and similar items complete. (Water proofing material shall be measured and paid for separately).
M&L for cutting grooves in brick wall, 75mm wide and 65mm deep and shaping horizontal face of groove with cement mortar (1:3).
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish to a distance exceeding 1 km but not exceeding 2 km.
M & L for non skid coloured ceramic tiles of size minimum 400mm x 400mm, 7 to 8 mm thick (square/rectangular), in floors etc. set and jointed in neat cement slurry with the joint of min width 3 mm, filled with epoxy in full depth of tiles as per manufacturer's instructions and pointed in white or coloured cement to match the shade of tile with including 15 mm thick Screed bed or bedding layer in CM (1:6) complete all as specified. Note: Only course sand shall be used in screed bed.
S&F glazed ceramic coloured tiles 450 x 350mm, 7 to 8mm thick in verticle surfaces such as dado / skirting, set and jointed in neat cement slurry and pointed in white or coloured cement pigmented to the match the shade of tiles laid over and including 10 mm thick rendering in cement mortar (1:4) as backing coat and finish the surface rough to receive the tile.
M & L for machine cut kota stone slab flooring minimum size 450 mm x 450 mm, 18 to 20 mm thick laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing laid over and including 20 mm thick Screed bed or bedding layer in CM (1:6).
All as per item No 50 above but in vertical surfaces such as steps , riser , skirting, dado and pillars as directed at site including 10 mm thick rendering as backing coat in cement mortar (1:4).
M&L for roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc.
M&L for marble work (udaipur green) 18 to 20 mm thick (table rubbed and polished) in steps, jambs, pillars, window cills, platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of marble and roundening to the edge of stone slabs on edges including M&L for 15 mm thick Screed bed or bedding layer in CM (1:6).
S & F pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of any colour as approved, having tensile strength of 550 Mpa as in crumple sheet / cladding to columns or fixed to wall with the help of plastic plugs and black screws with one washer each @ 200 c/c staggered at both sides, one side of sheet shall have oval type holes including taking down old crumple sheet complete all as specified.
Supply only 15mm bore chromium plated, fancy type, quarter turn Pillar cock screwed down high pressure, with or without lettered Hot ot Cold with long screwed shanks and fly nuts screwed for iron pipe complete all as specified.
S & F in repairs, PVC connections 15 mm bore, 450 mm length, heavy duty, with PTMT nuts.
S & F in repairs brass chromium plated shower rose 125 mm size with or without swivel joints fix to steel pipe or union complete all as specified and as directed.
S&F in repairs, brass chromium plated tubular towel rail, 20 mm dia, D type, 600 mm long between flanges fixed with CP screws and wooden cleats.
S & F in repairs, stainless steel chromium plated soap tray of size 100 x 100 x 60mm and fixed on wall with chromium plated brass screws complete.
S&F in repairs stop valves, chromium plated, angular type, quarter turn, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions for 15 mm bore dia of pipe.
S&F in repairs stop valves, cast copper alloy, fancy type, quarter turn, chromium plated with long shank and cup (concealed type) screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions for 15 mm bore dia of pipe.
S&F in repairs, 15 mm bore chromium plated, fancy type, quarter turn, bib taps cast copper alloy with crutch or butterfly handle, screwed for iron pipe, or for brass ferrule complete all as specified and as directed.
S & F grating doom 125mm dia with waste hole of PTMT (minimum weight 40 gm).
S&F in repairs drapery rod (conduit) of dia not less than 25mm duly powder coated of shade as decided by Engr-in-Charge including ABS plastic finials of approved shade and including standard MS poder powder coated brackets fixed to walls with rawl plugs and steel screws complete.
M & L for 15 mm bore GI pipe, medium grade, ISI marked, with all fittings and fixed complete to walls and ceilings or laid in floors including taking up or down 15 mm bore existing steel tubing and connections complete.
M & L for 20 mm bore GI pipe, medium grade, ISI marked, with all fittings and fixed complete to walls and ceilings or laid in floors including taking up or down 20 mm bore existing steel tubing and connections complete.
M & L for 25 mm bore GI pipe, medium grade, ISI marked, with all fittings and fixed complete to walls and ceilings or laid in floors including taking up or down 25 mm bore existing steel tubing and connections complete.
M & L for 40 mm bore GI pipe, medium grade, ISI marked, with all fittings and fixed complete to walls and ceilings or laid in floors including taking up or down 40 mm bore existing steel tubing and connections complete.
M & L for 40 mm bore GI pipe, medium grade, ISI marked, with all fittings and fixed complete to walls and ceilings or laid in floors.
S&F PVC (SWR) 110mm bore pipes single socketed, ISI marked, in any length with rubber ring joints, fixed to walls with and including 40 mm x 3mm GI flat clamp including taking down old pipes and fittings.
S&F PVC (SWR) 110mm bore bends / shoes of any radius.
S&F in repairs vitreous china squatting pan, 'Orissa' pattern, size 580mm x 440mm, white, with integral foot rests including connection to trap, and to flushing pipe, anti-syphonage pipe, etc. including making good to floor and excluding flushing cistern, flush pipe and waste pipe.
S & F in repairs PVC valveless, syphonic action type, flushing cistern, 10 litres capacity, low level, white, with inlet, ball valve, float and handle including brackets and PVC flushing pipe 32mm dia 900 mm long including S&F long P trap. complete.
S & F in repairs vitreous china wash hand basin, white, of size 550mm x 400mm , excluding waste, chain and plug and porcelain stopper but including 32 mm dia waste coupling fancy type chromium plated, and PVC waste pipe of 32 mm dia and fixed all as directed complete, .
M&L for urinal partition of green marble slab of size 1000 mm x 450 mm, 20 to 25mm thick, fixed to wall with cement mortar (1:2) in minimum depth of 50 mm with round edge, exposed corner with round shape in min radius 100 mm, pre polished on both sides complete.
Taking down carefully and re-fixing of vitreous china urinal, any type, including and providing and fixing plugs, bedding urinal against wall in CM (1:2) securing urinal to plugs with and including 60 mm long brass screws, pointing around urinal back in cement, S&F automatic flushing cistern with brackets and spreader, flush pipe, grating and union for discharge pipe complete.
Cutting into existing manholes, sump for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section ) in cement concrete (1:2:4) type B-1 smooth finished, and reforming benching as required for 150mm dia pipe complete all as specified and as directed.
Dismantling of 100mm /75mm / internal dia cast iron or reinforced concrete PVC drain pipes, jointed in cement mortar and taking out of trenches, fixed to wall including all fittings.
S & F 75 mm bore cast iron (spun) soil, waste and vent pipes, ISI marked in any length with or without ears, with cement joints, fixed to walls with and including suitable size clamps / laid in trenches
S & F 100 mm bore cast iron (spun) soil, waste and vent pipes, ISI marked in any length with or without ears, with cement joints, fixed to walls with and including suitable size clamps / laid in trenches.
S & F 100 mm bore cast iron bends (any radius), diminishing pieces or tapers (large bore measured) with oval access door.
S & F 75 mm bore cast iron bends (any radius), diminishing pieces or tapers (large bore measured) with oval access door.
Extra for joints over cast iron pipe of 100/75 mm bore pipes, bend joints etc provided Epoxy joints in lieu of cement joints complete.
S&F 75 mm dia stainless steel floor trap with grating incluing jointing to waste pipe fixed in cement concrete (1:2:4) type B-1, complete all as specified.
S & F 100 mm dia cast iron branch pieces, single (equal or un-equal), ordinary or inverted (spigot or socket type) or with parallel branches with oval access door complete.
S & F 75 mm dia cast iron branch pieces, single (equal or un-equal), ordinary or inverted (spigot or socket type) or with parallel branches with oval access door complete.
S & F 100mm dia cast iron branch pieces, double (equal or un-equal), ordinary or inverted (spigot or socket type) or with parallel branches/ cross/Y junction etc.
S & F 100mm dia cast iron bends (any radius) with duck's foot or heel rest.
S&F 100 mm cast iron Cowls.
S&F 1000 litres capacity Rotational moulded polyethylene in white colour, three layered, water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position including dismantling of old water tank of any size and any type and removing rubbish to a distance exceeding 1 km but not exceeding 2 km etc all as directed.
S&F ball valves high pressure of PTMT with epoxy coated Aluminium rod and high density plastic ball screwed for iron pipe of size 20 mm bore (minimum weight 210 gram).
S & F in repairs Gun metal globe or Gate valve , with iron wheel , screwed both ends for iron pipe or for unions for 20 mm bore dia of pipe.
Taking down old cement plaster including raking out joints hacking for key scrubbing down with water etc and removing rubbish to a distance exceeding 1 km but not exceeding 2 km etc complete all as specified.
M&L for rendering 15 mm thick in cement mortar (1:6) on internal wall surfaces of brick work or concrete surfaces and finishing the surface even & smooth without using extra cement complete all as specified.
M&L for rendering 15 mm thick in cement mortar (1:4) on external wall surfaces of brick work or concrete surfaces even and fair without using extra cement mixed with liquid water proofing material as per manufacturer's instruction complete all as specified. (Liquid water proofing material shall be measured and paid for separately.)
M&L for rendering 5 mm thick in cement mortar in (1:3) finishing the surfaces even and smooth on ceiling complete all as specified.
Demolition of brick work masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stone work and pre cast concrete articles in foul condition.
M & L for Brick work using old size bricks, straight or curved on plan exceeding 6 metre mean radius built in cement mortar (1:6).
M & L for Brick work using old size bricks, straight or curved on plan exceeding 6 metre mean radius built in cement mortar (1:4).
M&L for brick work using sub class ‘B’ old size bricks, straight or curved on plan to any radius in half brick thick walls, built in CM (1:4).
M&L for 75 mm thick PCC (1:3:6) type C-1 using 20mm graded stone aggregate as in plinth protection finishing the surface even and smooth without using extra cement.
M & L for preparation of newly plastered surfaces of internal walls and applying the following:- (i) Applying wall care putty in two coats on wall surfaces & smoothening the surface with sand papers/ mechanized sanding etc (preparatory to paint as directed) complete all as specified. (ii) Two coats of 100% acrylic emulsion paint by using airless spray/ roller over and including a coat of acylic internal primer. Note :- Contractor may use manual tools for surface preparation with prior approval of Engr- in- charge in writing in case use of mechanical equipments are not possible.
Complete removal of existing treatment on wall (any number of layears) by scrapping with steel wire brushes or any other means, including filling depressions of scrapped surfaces and M & L for preparation of old plastered surfaces of internal walls and applying the following:- (i) Applying wall care putty in two coats on wall surfaces & smoothening the surface with sand papers/ mechanized sanding etc (preparatory to paint as directed) complete all as specified. (ii) Two coats of 100% acrylic emulsion paint by using airless spray/ roller over and including a coat of acylic internal primer. Note :- Contractor may use manual tools for surface preparation with prior approval of Engr- in- charge in writing in case use of mechanical equipments are not possible.
M & L for preparation of newly plastered surfaces of external walls and apply two coats of Cement base paint over a coat of alkali resistant primer all as specified.
M&L for preparation of newly plastered or unplastered surface and applying three coats of white wash on ceilings.
M&L for preparation of old plastered or previously treated surface and applying two coats of white wash on walls.
M&L for preparation of old plastered or previously treated surface and applying two coats of white wash on ceilings.
Complete removal of existing treatment of external walls by scrapping with steel wire brush or any other means including filling depressions of scrapped surfaces and M & L for two coats of Cement base paint over a coat of alkali resistant primer of any shade.
M & L for painting to old steel and iron surfaces of any description, over 10 cm in width or girth, not otherwise described with one coat of synthetic enamel paint including preparation of old painted surfaces.
M & L for painting to old wood and wood based surfaces of any description, over 10 cm in width or girth, not otherwise described with one coat of synthetic enamel paint including preparation of old painted surfaces.
Demolition of RCC of any description and in any position not otherwise specifically provided for, (reinforcement cut as required to facilitate demolition).
M & L for M-25 design mix concrete using 20 mm graded stone aggregate in columns (jacketing) and the like, finished exposed surface fair and even. (Reinforcement and form work shall be measured and paid separately)
M & L for M-25 design mix concrete using 20 mm graded stone aggregate in chajjas / beams and slabs and the like, finished exposed surface fair and even. (Reinforcement and form work shall be measured and paid separately)
Use and waste of formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (horizontal or sloping) for flat rough surfaces of concrete.
Use and waste of formwork to sides of pillars, posts, struts, piers, columns and stanchions having square, rectangular or polygonal shape with rough finished surface of concrete.
M & L for TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips.
M & L for TMT bars 5mm dia and over upto and including 10mm dia, in stirrups, spacers and binders.
Demolition of existing RCC Jallies of any thickness.
Taking down shutters of any description exceeding 1 Sqm and not exceeding 2 Sqm each and removal from site.
M&L for precast cement concrete type B-0 (1:2:4) as in louvers and jallies 40 mm thick (measured solid) including all moulding but excluding frame set in CM (1:4).
Chipping of old decorated concrete as in beam, column, ceiling, chajja etc to open reinforcement including all scaffolding, shuttering, props etc upto double storey building all as directed.
M&L for applying rust remover with brush for complete wetting rusted metal surface and allowed to react it for 16 to 24 hrs. After 24 hrs, white layer will appear which will protect further corrosion of metal/steel for about 5 to 7 days incl surface preparation and erection of steel props, before applying protective coating, the surface should be wire brushed and thoroughly cleaned for dust with dry cloth, complete all as specified and directed. (Make : Sika/ Fosrock/ Master Builders)
Providing and application of passivator/anti corrosion coating to the steel reinforcement shall be applied. The material shall be two components, cement based polymer modified tow components coating for corrosion protection. The material shall be pre-packed and ready to use. It shall be fully compatible with the reinstatement methods adopted completer all as specified and directed this shall include surface preparation and errection of steel props as required for the application (Make : Sika/ Fosrock/ Master Builder).
M&L for polymer modified mortar (pre-packed ready to use) for the beam, column, ceiling, chajja to rectangular/ square/flush to shape complete all as specified and direceted. (Make : Sika/ Fosrock/ Master Builder).
M&L carbon fiber laminate for strengthening of RCC members such as columns, beams and slab over coat of primer and saturants (one or two coats as per manufactures specification) complete all as pr specified and directed. (Make : Sika/ Fosrock/ Master Builder).
M&L for applying one coat of Dr Fixit Pidecrete URP in chajjas, staircase etc by using 2 Sqm per Kg URP + cement in the proportion (1:1.5) and making pidecrete solution and applying by brush etc all as directed.
Internal Electrification
Taking down carefully existing unserviceable copper / aluminum point wiring (light, fan, socket) complete including removal of unserviceable fittings such as switches, switch-sockets, ceiling roses, light fittings etc including concealed conduit and sunken boxes and removing the retrieved materials from site including making good the disturbed surface of walls, floors, ceilings etc to match with the adjoining work complete all as specified and directed.
M & L for point wiring with multi stranded copper conductor FRLSH cable, 1100 volts grade PVC insulated and unsheathed of size 1.5 Sqmm single core in and including PVC concealed conduit not less than 20mm dia ( medium duty ISI marked) and conduit fittings with and including 3 mm thick bakelite laminated sheet top cover for one fan / light controlled by one switch including provision of 1.5 Sqmm PVC insulated & unsheathed with single core, multi stranded copper conductor FRLSH cable as earth wire to common earth & connecting to earth dolly all as specified and directed.
All as per item No 130 here in before but for socket outlet 5 pin, 6 Amp on same board complete all as specified.
All as per item No 130 here in before but for socket outlet 5 pin, 6 Amp on independent board but not below the switch board complete all as specified .
All as per item No 130 here in before but for one socket outlet 6 pin, 6/16 Amp multipurpose 2 in 1 on independent board with cable of 2.5 Sq mm, multi stranded copper conductor FRLSH cable including provision of 2.5 Sq mm PVC insulated solid copper conductor FRLSH cable continuos as earth wire connected to earth dolly, conductor etc.
All as per item No 130 above but for one light point controlled by two, two way switches .
S & F Switch, flush type, single pole, one way, 5/6 Amp .
S & F Switch, flush type, single pole, two way, 5/6 Amp .
S & F Switch, flush type, single pole, one way, 15/ 16 Amp .
S & F socket, multipurpose, 2 in 1, 5 Pin, 6 Amp, flush type. (Note: Switch and socket shall be of same make.)
S & F socket outlet universal, multipurpose, 2 in 1, 3 Pin 6 Amp and 6 pin 16 Amp, flush type. (Note: Switch and socket shall be of same make.)
S&F, fan regulator electronic step type (1-5), socket type 230-240 Volt, AC supply, complete all as specified and directed.
S & F ceiling rose, 3 plate, surface bakelite type, Polycorbonate body, 6 Amps, 250 Volts AC, 65 x 50 mm, three terminal (ISI marked) complete all as specified.
S & F 18/20 watt Retro LED tube light fitting, wall/surface mounted, IP 20 protection, conforming to IS 16106/IS 16107, minimum 6000K batten decorative type 4 feet long polycarbonate body, white, in built LED driver, power factor>0.95 , Make all as per Crompton Cat Part No. DMLN1LT8-16 (for batten) and Cat part No. LT8-20-865-2 (for tube light) including 18/20 watt tube rod or equivalent model of any make given in Appx 'B' connecting to electric point by using PVC insulated twin core copper conductor cable of suitable size including taking down old existing light fitting all as directed.
S & F LED mirror light fitting of 12/14 watt, 6000K, linear & compact with decorative grey end caps, polycarbonate body and ribbed opal diffuser complete including 12/14 watt tube rod all as model No LCL-14-CDL of Crompton with 14 watt rod or equivalent model of approved make from list of make attached in tender documents including connecting to electric point by using PVC insulated twin core copper conductor cable of suitable size including taking down old existing light fitting.
S & F in repair, Lamp holder of PVC/Polycarbonate type with back plate suitable for batten fitting including 9 watt LED bulb.
S & F energy efficient LED street light fitting of 45 Watt maintainable type with IP 66 degree of protection, PF > 0.95 with voltage range 140 to 270 Volt, fitting should be provided with inbuilt 5 KV minimum surge protection, short circuit and over voltage protection facility for Driver and fitting including 45 watt LED lamp with GI brackrt - 01 No, MS clamp-02 Nos suitable for walls/ columns and making electrical connection with providing of 1.50 metre long twin core round copper conductor cable of suitable size and testing complete all as per SYSKA cat part No. SSK-SLR-45W or equivalent model of any make given in Appx 'B', Cat Part No. as approved by GE complete all as specified including taking down old unserviceable existing street light fitting of any type and capacity from pole along with accessories.
S & F surface mounted, decorative round plastic bulk head luminaire comprising of high brightness LED lamp 10/12 watt, 6000K polycarbonate including all other accessories and fitting arrangement including electric connection connecting with using flexible copper wire twin core upto ceiling rose/connector. Make:-Crompton cat part No LBHE-10-CDL or equivalent model of approved make from list of make attached in tender documents including taking down old existing light fitting.
S & F sheet metal enclosures double door made out of CRCA mild steel sheet, concealed, surface mounting, acrylic door, IP-43 protection, 8 way, DB SPN 230 Volts, with 200 Amp rated bus bar, dust and vermin proof suitable for fixing MCB's and Isolators etc including taking down old unserviceable DB.
S & F sheet metal enclosures double door made out of CRCA mild steel sheet, flush mounted, acrylic door, IP-43 protection, 4 way, DB TPN 415 Volts, with 200 Amp rated bus bar, dust and vermin proof suitable for fixing MCB's and Isolators etc including taking down old unserviceable DB.
S&F blanking plate.
S & F MCB, SP, 6 to 32 Amps, 'C' curve, 230 Volts, breaking capacity not less than 10 KA with over load and short circuit protection including taking down old unserviceable MCB complete all as specified.
S & F MCB, SPN, 40 Amps, 'C' curve , 230 Volts, 50 Hz, breaking capacity not less than 10 KA with over load and short circuit protection and including taking down old unserviceable MCB complete all as specified.
S & F MCB, TPN, 63 Amps, 'C' curve , 415 Volts, 50 Hz, breaking capacity not less than 10 KA with over load and short circuit protection and including taking down old unserviceable MCB complete all as specified.
M & L for sub main wiring with 2 single core cable PVC insulated unsheathed of copper multi strandard conductor FRLSH cable of size 6 sqmm, 1100 votls grade drawing through in and including PVC concealed conduit 20 mm dia medium duty including acessories such as Tee, bend, Elbow etc, ISI marked with and including PVC insulated 6 sqmm unsheathed multistranded FRLSH copper conductor cable for earth continuity and connected to common earth dolly including cutting chasing of wall, if required and making good disturbed surface in CM (1:3) and finishig the surface to match with existing surface etc including taking down old unserviceable wiring 6 Sqmm complete all as specified. Note:- Two runs of cable, one run of earth wire and one run of PVC conduit shall be measured as one unit. (Note: If at site any nos of geyser, ceiling fan, exhaust fan, electric meter is found before starting the work, the contractor shall hand over these items to Unit Rep in writing to avoid the last minute complicacies and refixing of electric meter is the sole responsibility of the contractor before handing over the site to user.)
M & L in replacement of earthing complete with galvanised steel earth plate electrode 600 x 600 x 6 mm thick burried directly in ground to depth of pit not less than 2.25 m below normal ground level with top edge of the plate not less than 1.5 m below normal ground level surrounded from all sides by 15 cm thick packed layer of charcoal / coal dust and common salt filling in alternate layers and connected to galvanised earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers of GI or steel including GI protection pipe 15mm dia light grade upto the extent of 7.5 metre and connecting to earthing test point, main switch board including GI pipe 20 mm dia light grade for watering, MS funnel and bringing out the watering pipe upto 30 cm above the normal ground level plugged at top including all fitting including PCC earth pit with PCC 1:2:4 type B-1 using 20mm graded stone aggregate and RCC pit cover including necessary earthwork and excavation in any type of soil complete all as specified as shown in electrical plate No 3 of SSR Part-I and testing on completion. Note :- (a) PCC chamber shall be constructed at least 1.5 m away from earth pit. Pipe for watering shall be provided in slanting manner. (b) 4mm dia GI wire and 15mm dia light grade GI protection pipe upto 7.5 metre shall deemed to be included in quoted rate.
M/s PANKAJ KUMAR
M/s MITTAL CONSTRUCTIONS
BANSAL BUILDERS
SHARDA ENTERPRIES
M/s Nuway Constructors India Pvt. Ltd.
M/s Balvinder Singh Engineer and Contractors
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .