Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.8 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹21.6 L+₹85,356 (4.11%)Rejected-Finance B 12 BASEMENT PLOT NO 19 RETAIL BUSINESS CENTRE ADITYA COMPLEX NANGAL RAYA SOUTH WEST NEW DELHI 110046 | NEW DELHI | DELHI | 110046 | L2 | Rejected-Finance Being not L1 | |
| 3 | L3₹26.0 L+₹5.2 L (25.0%)Rejected-Finance PLOT NO 59 60 WAZIDPUR JAIMAU KANPUR 208010 | KANPUR NAGAR | UTTAR PRADESH | 208010 | L3 | Rejected-Finance Being not L1 |
Tender Value
₹25.0 L
EMD Value
₹49,960
Closing Date
18 Mar 2022, 3:30 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Niteen M Waghmare
AGE(I)(U) B/R DELHI CANTT-10
REPAIRS TO BRICK WORK, CEILING PLASTER AND OTHER MISC WORK OF MES INSTALLATIONS AREA UNDER AGE(I)(U) B/R DELHI CANTT-10
2022_MES_504514_3
9085/E8
Open Tender
Civil Works
Item Rate
120 days
AGE(I)(U) B/R DELHI CANTT-10
As per tender documents
7 documents required · 7 mandatory
₹500
AGE(I)(U) B/R DELHI CANTT-10
₹49,960
25 Mar 2022
25 Feb 2022
19 Mar 2022
25 Feb 2022
18 Mar 2022
4 Mar 2022
60 days
Amount
Dismantled of brick masonry work built in Cement mortar or cement lime mortar complete all as specified and directed by Engr-in-Charge.
M&L for brick work with sub class "B" bricks (old size) straight or curved on plan exc 6 m mean radius, built in CM 1:6 complete all as specified and directed.
M&L for brick work with sub class except "B" bricks (old size) straight or curved on plan exc 6 m mean radius, built in CM 1:6 complete all as specified and directed.
Removing mortar from and cleaning bricks, stacking for measurement including all extra handling and removal and disposing of rubbish complete all as specified and directed.
Taking down cement or cement lime plaster , any description on brick or stone walls, etc including racking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed.(Complete removal surface to be verified by Enginr-in-Chrage before apply next treatment)
M&L for 12mm thick ready mix plaster (Make: Ultratech readiplast / Birla Aerocon RMP / ACC Suraksha RMP) on brickwork or concrete surface of wall (Internal Surfaces) finished even smooth complete all as specified and directed by Engr-in-charge.
M&L for 15mm thick ready mix plaster (Make: Ultratech readiplast / Birla Aerocon RMP / ACC Suraksha RMP) on brickwork or concrete surface of wall (External surfaces) using WPC finished even smooth complete all as specified and directed by Engr-in-charge(Note: WPC shall be paid seperately).
M&L for 5 mm thick ready mix plaster (Make: Ultratech readiplast / Birla Aerocon RMP / ACC Suraksha RMP) on ceiling surface finished even smooth complete all as specified and directed by Engr-in-charge.
M&L for preparation of new plastered surface of walls & apply two coat of cement base paint complete all as specified and as directed.
M&L for preparation of newly plastered surfaces of ceilings & apply three coats of white wash complete all as specified.
M&L for preparation of newly plastered surfaces of wall & apply two coats of dry distemper, white or tinted over 1mm thick wall care putty complete all as specified and directed. Make-Asian/Berger/Nicholson
Demolition of cement concrete (reinforced) in roofs, floor (other than ground floors), beams staicase, landing chajjas and similar suspended work complete all as specified and as directed.
Excavation in trenches , not exc 1.5 m wide and n exc 1.50 m in depth for foundation etc or for shafts, wells, cesspits, manholes, pier holes etc not exc 10 sqm on plan and not exc 1.5 m in depth and getting out in soft/loose soil complete all as specified and directed.
Returning, filling in, spreading, levelling, watering and well ramming in layers not exceeding 25cm thick each complete all as specified and directed
Removal of excavated soil to a distance exceeding 250m and not exceeding 500m depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed
M&L for cement concrete 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) as in foundation filling and mass concrete complete all as specified & directed.
M&L for Brick work with sub class’B’ well burnt bricks (best quality), having compressive strength of 100 kg/Sq cm straight or curved on plan exc 6m mean radius built in cement mortar 1:6 & pointed flush in the same mortar as the work proceeds incl demolition of old bricks, complete all as specified & directed.
M&L for brick work with sub class’B’ bricks having compressive strength of 100 kg/Sq cm straight or curved on plan to any radious in half brick thick walls built in cm 1:4 and pointed flush in same mortar incl demolition of old bricks complete all as specified & directed.
M&L for cement concrete 1:2:4 type B-1(using 20mm graded crushed stone aggregate) in benching, coping etc including weathering slightly rounded or chamfered angles including necessary form work, complete all as specified and directed.
Supply only integral water proofing compound. Make: Dr. Fixit or equivalent
S&F factory made 75mm thick SFRC (Steel fibre reinforcement concrete ) manhole cover medium duty M-25 grade with SFRC frame of clear size exc. 0.35 Sqm but n.exc 0.90 Sqm, provided with provision of two lifting hooks welded at appropriate location, complete all as specified & directed.
Cutting in existing manholes (150mm to 300mm dia) for connecting new drains ,making good to pipe and rendering cutting out existing benching for and forming branch channel,and reforming benchingas required.
M&L for 200mm nominal size double wall corrugated HDPE pipes stiffness class SN 8 high density, polyethylene pipe resistent to chemicals, easy and light weighted, long living, low friction, flexible, sun resistant pipe and laid in trenches incl demolition of old pipes complete all as specified and directed. Make: Supreme "Ultra plus" or equivalent.
M&L RCC M-25 (Nominal Mix) type B-1 1:2:4 as in foundation, incl raft, footings foundation beams, plinth beams, bases for columns etc using 20mm graded stone aggregates complete all as specified & directed.
M&L RCC M-25 (Nominal Mix) as in columns etc using 20mm graded stone aggregates complete all as specified and directed.
M&L RCC M-25 (Nominal Mix) as in beams, cantilevers, bressummers, lintels over 1.50m span using 20mm graded stone aggregates complete all as specified and directed.
M&L RCC M-25 (Nominal Mix) as in slabs supported on walls,beams and columns in floors,roofs,landings,balconies,canopies,deck slabs and in shelves and the like complete all as specified & directed.
M&L RCC M-25 (Nominal Mix) as in chajjas complete all as specified & directed.
M&L for form work to sides of concrete foundations, footings, bases of cols, raft and raft beams, side and soffits (if any) of foundation and plinth beams and similar works rough finished surfaces of concrete complete all as specified & directed.
M&L for form work to sides of pillars, posts, struts, piers & columns rough finished surfaces of concrete for sqaures or rectangular and similar rough finished surfaces of concrete flat complete all as specified & directed.
M&L for form work to sides and soffits of floor/roof beams rough finished surfaces of concrete complete all as specified & directed.
M&L for use and waste of formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work, for rough finished surfaces of concrete complete all as specified and directed.
M&L for mild steel reinforcement TMT bars, 10mm dia and over cut to length, bent to shape required including cranking, bending, spirally for hooping for columns, hooking ends and binding with and including MS wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified & directed.
All as per srl item No.33 above but size 6mm dia to 8 mm dia.
Dismantling floor, hearth or wall including cement mortar bedding (but not backing), removing servicable complete all as specified and directed.
M&L for coloured non skid ceramic tiles 7 to 8 mm thick (Square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over 15mm thick avg screed bed in CM 1:6 complete all as specified and directed.
M&Lfor coloured/printed glazed ceramic tiles 350x250x7mm /450x350x 7mm thick, on vertical surfaces such as skirting, dados and risers to steps etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match. Over 10 mm thick rendering in CM 1:4 complete all as specified and directed.
S&F CPVC pipe 20mm external dia with all fittings and fixed complete to walls ceilings or laid in floors of medium grade including dismantling old GI pipes complete all as specified and directed.
S&F in repairs vitreous china squatting pan 'Orrisa' pattern size 580x440mm white with integral foot rest, incl. CI floor trap( long nose) 'P' or 'S' trap, 100mm bore complete all as specified.
S&F in repair 10 Ltrs capacity PVC valveless symphonic action type flushing cistern white low level with inlet, ball valve float handle including bracket and Supply only Flush pipe of polyethylene of low or high density or PVC,32mm bore as per existing for low level cistern complete all as specified and directed.
S&F in repair rotational moulded polythene, two layers, water storage tank 500 Ltrs capacity, closed top, cylindrical, hoisted and fixed in position including , 20mm bore ball valves high pressure of PTMT with epoxy coated Aluminium rod & high-density plastic ball screwed for iron pipe and fixed complete all as specified and directed.(Minimum weight 20mm-210 gms.).
S&F in repair PVC connection 15mm size with PTMT nuts of length 450mm.
S&F in repair 15mm bore stop valves, cast copper alloy, screwed down ,high pressure, with crutch or butterfly handles,screwed both ends for iron pipe or for unions and fixed complete all as specified and directed.
S&F in repair 15 mm bib taps, cast copper alloy with chromium plated, crutch or butterfly handle screwed down, screwed for iron pipe and fixed complete.
S&F in repair 15mm bore angle stop valve ,cast copper alloy with chromium plated, , high pressure screwed for iron pipe or for unions and fixed.
Taking down PVC pipe of any size of any description with fittings complete all as specifed and directed.
S&F for 110mm bore PVC (SWR) pipes single socketed Pressure rating @4Kg/Sq cm length "medium grade" with rubber ring joint, fixed to walls with dash ture nut and bolt at every 2 mtrs length complete all as specified and directed by Engineer-in-charge.
All as per ser item No. 47 above but laid in trench or in floor.
S&F for 110mm bore PVC (SWR) Gully Trap setting / jointed with solvent cement complete all as specified and directed.
S&F for 110mm bore PVC bends/junction any radius complete all as specified and directed.
S&F in repair for 75mm bore PVC pipes single socketed with rubber ring joint, fixed to walls with dash ture nut and bolt at every 2 mtrs length complete all as specified and directed.
All as per ser item No. 51 above but laid in trench or in floor.
S&F in repair for 75mm bore PVC bends/junction any radius complete all as specified and directed.
S&F in repair PVC (SWR) floor trap,plain with grating 75mm bore including jointing in PCC 1:2:4 type B-1 (using 20mm graded stone aggregate) complete all as specified and directed.
S&F of LLDPE septic tank with upflow filter including media designed to carry sewage and sullage water,excavation in any type of soil, PCC 1:4:8 below foundation,Vent shaft,connection etc complete for 10 users complete all as specified and directed by Engr-in-Chrage.
M&L for soakage wells excavation,in any type of soil,foundation in PCC 1:3:6,walls of honey combed masonry with top ring of M25 concrete including intercepting chamber and screen chamber made of Brick masonary in CM,RCC cover slab in M25/SFRC cover,interconnecting pipes of RCC/DWC complete filled with brick bats of of size 1.2 M dia x 1.50M effective depth, complete all as specified and directed by Engg-in-Chrage.
Dismantling structural steel work including doors, gates but excluding framed truss etc complete all as specified and as directed.
M&L for framed work as in door or gates of angle or other section complete drilled for fixing sheeting with all fitting and fixture complete all as specified and directed.(Fe-410-W(Gde-E-250 quality-A) (used for window also)
Taking down chowkat with shutter n. exc 1.5 sqm each and removing from site as directed.
S&F for steel window with double shutters for gauged and glazed side hung shutter including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars dovetailed or welded complete all as specified and as directed.
S&F for steel window with side hung shutter including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars dovetailed or welded complete all as specified and as directed.
Cutting holes exc one brick but n.exc two brick walls built in cement mortar or cement lime mortar and stone walls built in lime mortar for inserting holdfast and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 type B-1 as required complete all as specified and as directed.
S&F as in repair stainless steel wire cloth 0.36mm normal dia of wire and average with a apparture 1.40mm and fixed with tinned tacksor stainless steel wire staples as specified and directed.
Hacking out old broken glass (any thickness, size, quality or description) from wooden/steel frames, glazed with oil putty or fixed with beads.
S&F Sheet glass, 3mm thick ordinary quality, and glazing with oil putty in squares, not exceeding 0.50 sqm in each pane complete all as specified and directed.
M&L for preparation of new steel surafces & apply one coat of synthetic enamel paint, complete all as directed.
Scrapping of old tarfelt for roof treatment over concrete surface of roof incl finishes or junction or parapet and cleaning the surface ( buy mechanical means like grinder etc ) complete all as specified and directed.
M&L for cement concrete 1:2:4 type B-1 (Using 20mm graded stone aggregate) on roof padding with water proofing compound surface finished even and smooth without using extra cement complete all as specified and directed (Rate of WPC shall be included in this unit rate).
M&L for water proofing treatment in following stages:- 1. Rendering in CM 1:3 with waterproofing liquid as per manufacturer's instruction over concrete surface finished even and smooth without using extra cement. 2. First coat of bitumen primer confirming to IS-3384@ 0.40 Kg/Sqm over plastered surface.(Bitumen primer shall be TANK MASTIC of M/S STP Ltd or ‘EMW FLATE’ of M/S Texas India Ltd). 3. Second coat of binding material using blown type bitumen confirming to IS-702 Gde 85/25 @ 1.2 Kg/Sqm applied over bitumen primer. 4. Third layer of APP polymeric water proofing membrane, minimum 3mm thick and weighing not less than 3.0 Kg/Sqm with a centre core of 90 micron high density polyethylene film protected on both sides with a high quality polymeric asphaltic mix, the polymeric asphaltic mix will be protected on both sides with thermo fusable HMHDPE film of make super thermolay manufactured by STP Ltd or ‘Hyper Plas’ (Polyster) manufactured by M/S IWL Ltd or ‘Shaliplas’ (polyester) manufactured by M/S Capital Steels and chemicals Pvt Ltd as approved by GE, black finish reinforced with non-woven polyester matt, with a thermo fusable finish.torching overlaps with a propane or a butane gas torch, with a overlap of 75mm at the sides and 100mm at the ends complete all as specified and as directed. 5. Final coat of binding material using blown type bitumen confirming to IS-702 Gde 85/25 @ 1.2 Kg/Sqm applied over APP membrane. Over this layer stone dust @ 0.50 Kg/Sqm shall be applied uniformly.
M&L for providing cement concrete 1:2:4 type B-1 (20mm graded stone aggregate) in roof ,kerb,mud slope rounder or chamfered on edges coping kerb water tough and like incl weathering ,slightly roundered or chamfered angles and thtroating directed incl necessary formwork complete all as specified and directed.
S&F of LED recessed mounting square slim LED down lighter 34 Watt for AS/GB/POP ceiling 2'x2' size complete with internally prewired and connecting up with twin core flexible copper conductor cable of suitable size complete all as specified and directed by Engr-in-Charge.
S&F of decorative ultra slim square profile LED lighting 20 W LED 6500 K fixture with extruded polycarbonate, environmental Catpart of Havells LHEXACP7UN1W020 or equivalent.
S D Constructions
B. S BUILDERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .