Loading…
Loading…
Tender Value
₹89.3 L
EMD Value
₹1.8 L
Closing Date
21 Jan 2026, 3:00 pmClosed
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
Above/Below/Par
SIG WORKS
14 conditions · 3 needing a document upload
The tenderer must have minimum average annual contractual turnover of V/N or V whichever is less, where: V= Advertised value of the tender in crores of Rupees N=Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of 'total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure VIB, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet As per Clause No. 10.2 of Tender Form (second Sheet) of Annex. I of Part-I of GCC- 2022,with up to date correction slip.
The tenderer must have successfully completed or substantially completed any of the following categories of work(s) during last 07 (seven) years, ending last day of month previous to the one in which tender is invited: (i) Three similar works each costing not less than the amount equal to 30% of advertised value of the tender, or (ii) Two similar works each costing not less than the amount equal to 40% of the advertised value of the tender, or (iii) One similar work each costing not less than the amount equal to 60% of the advertised value of the tender Work experience certificate from private individual shall not be considered. However, in addition to work experience certificates issued by any Govt. Organisation, work experience certificate issued by Public listed company having average annual turnover of Rs 500 crore and above in last 3 financial years excluding the current financial year, listed on National Stock Exchange or Bombay Stock Exchange, incorporated/registered at least 5 years prior to the date of closing of tender,shall also be considered provided the work experience certificate has been issued by a person authorized by the Public listed company to issue such certificates. In case tenderer submits work experience certificate issued by public listed company, the tenderer shall also submit along with work experience certificate, the relevant copy of work order, bill of quantities, bill wise details of payment received duly certified by Chartered Accountant, TDS certificates for all payments received and copy of final/last bill paid by company in support of above work experience certificate. As per Clause No. 10.1 of Tender Form second Sheet of Annex. I of Part-I of GCC 2022, with up-to-date correction slip.
Definition of similar work: "Any RRI/PI/EI/MACLS Supply, Installation Testing, Commissioning Signalling work OR Any RRI/PI/EI/MACLS Alterations Signalling work OR Any CTC/TMS Work ".
62 conditions · 5 needing a document upload
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Tenderer should note that tender will be dealt as per GCC 2022 and latest amendments to it.
Rates in the schedule items of work are inclusive of all taxes as per clause 37 of GCC-2022
Wherever there is any ambiguity in SOR Item Description, that particular item description in latest RDSO Specification to be considered as FINAL.
Telecom Circular No. 09/2023 (copy attached) shall be religiously followed for undertaking digging work in the vicinity of Signalling, Electrical and Telecommunication Cables. Zonal Railways issued local instructions/JPO for protection of cables while undertaking works in the vicinity of Railway Tracks in line with Telecom Circular 09/2023.
Signalling work in Connection with Upgradation / augmentation of Satellite Track Machine Depot at Bandikui Station in Jaipur division.
SNT-JP-28-2025-26~NWR
SNT-JP-28-2025-26
Open
Works - General
12 Months
Jaipur, Rajasthan
₹0
₹1.8 L
21 Jan 2026
29 Dec 2025
7 Jan 2026
94 items across 2 schedules
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 12,06,517.49 | ||
| — | 1.00 | — | — | ||
| Translation of Station Working Rules from english to hindi and framing out in DIGLOT form (or similar software )as per extant Rly practice. The required SWR in english will be provided by the contractor and has been covered separately in item no. 1.21 of Chapter 1 of this SOR. Inspection: Consignee Inspection charges: None Payment terms:100% after execution. | — | — | — | 4,478.18 | |
| — | 6.00 | — | — | ||
| Making photocopies & binding of the SWR literature in English/hindi/Diglot form as per Railway practice. Inspection: Consignee Inspection charges: None Payment terms:100% after execution. | — | — | — | 1,071.12 | |
| — | 1.00 | — | — | ||
| Designing and Plotting of Signaling Interlocking Plan(SIP) in AUTOCAD. Two copies of prints with soft copy will be submitted to Railway for checking. If alterations are suggested/proposed by Railways then again two copies of prints will be submitted for advance approval after carrying out all the alterations as suggested/proposed by the Railways. Tracings will be submitted for all the diagrams mentioned above for the purpose of approval by Railway prior to commissioning of station. Inspection: Consignee Inspection charges: None Payment terms:100% after execution.(Per Unit should be read as Per SIP) | — | — | — | 28,062 | |
| — | 100.00 | — | — | ||
| Preparation and supply of laminated one set of all the completion plans including circuit diagrams and indoor as well as outdoor completion documents on standard 75-micron polyester film for station in Auto CAD. 6 (Six) sets xerox copies will also be provided for each of the documents mentioned below: Cable Route Plan, Cable Core Chart, Location details plan for all the locations, Cable termination details, Signalling Plan, SWR Diagram, Wiring Diagrams, Selection table, Locking table, Contact analysis, Fuse and Tag Block analysis of Relay Rack, CT rack, Control cum Indication Panel/VDU Diagram, Power Panel Diagram, Track circuit plan, rack erection plan and Junction Box details etc. Inspection: Consignee Inspection charges: None Payment terms:100% after execution. | — | — | — | 16,107 | |
| — | 100.00 | — | — | ||
| Addition/alteration in existing relay room wiring. It includes supply of PVC insulated indoor Railway signalling cable @ 40<45@Core/40-Core) of (1/0.6) sqmm as per RDSO Spec.No.IRS/S-76/89 (Amnd.2 or latest) for wiring between relay room and SM's/Panel room & Relay room to DP in SM office for block working. This also includes supply of PVC insulated jumper wires of multi strand 16/.2 mm, tinned in all colours as per RDSO Specn.No.IRS-S-76/89(Amnd.2 or latest). This item will include bringing all the power supplies from power room to respective bus bars on relay racks by using 10/6 sqmm copper flexible wire as per instructions of engineer incharge. This will include wiring between control panel and relay room if required. All wiring will be done as per standard practice of North Western Railway with neat dressing & threading. The item includes supply & wiring of tag block, fuse with bases(G-Type and ND Type) and all other related material required for complete indoor wiring in relay room. Inspection: Consignee Inspection charges: None Payment terms:100% after commissioning. | — | — | — | 52,410 | |
| — | 5.00 | — | — | ||
| Supply of Q-Series LED ECR (Universal Type i.e.QECX-61), 4F/4B complete with plug board(base plate), connectors, retaining clips etc and conforming to BRS:941A STS/E/RELAYS/AC LIT LED SIGNAL/09-2002 ,Amdt.-1and RDSO Specn.No.IRS:S-34 & S-23 or latest.The interlocking code for this unit shall be ""ABDHK"". Inspection authority:- RDSO Inspection charges:- Borne by Railways Payment Terms:- 100% after supply. | — | — | — | 24,917.65 | |
| — | 10.00 | — | — | ||
| Supply of Q-Series Line Relay (QNA1 Type),AC immunized, 8F/8B, 24 V DC along with plug board (base plate), connectors, retaining clips etc and conforming to BRS-931A and RDSO Specn.No.IRS:S@ 45"44@ S-23 and S-60 or latest. The interlocking code for this unit shall be ""ABDGH"". Inspection authority:- RDSO Inspection charges:- Borne by Railways Payment Terms:- 100% after supply. | — | — | — | 39,136.7 | |
| — | 10.00 | — | — | ||
| Supply of Q-Series Line Relay (QNA1 Type), AC immunized, 12F/4B, 24 V DC along with plug board (base plate), connectors, retaining clips etc and conforming to BRS-931A and RDSO Specn.No.IRS:S@ 45"44@ S-23 and S-60 or latest. The interlocking code for this unit shall be ""ABDFH"". Inspection authority:- RDSO Inspection charges:- Borne by Railways Payment Terms:- 100% after supply. | — | — | — | 38,055 | |
| — | 10.00 | — | — | ||
| Supply of Q-Series Track Relay (QTA2 Type), AC immunized, 9 Ohms, 2F/1B along with plug board (base plate), connectors, retaining clips etc and conforming to BRS:939A & 966(Appendix F2) or latest.The interlocking code for this unit shall be ""FGHKX"". Inspection authority:- RDSO Inspection charges:- Borne by Railways Payment Terms:- 100% after supply. | — | — | — | 37,347 | |
| — | 10.00 | — | — | ||
| Supply of Q-Series Neutral Line Relay (QN1 Type ), 12F/4B, 24V DC complete with plug board(base plate), connectors and retaining clips etc and conforming to BRS- 930 and RDSO Specn.No.IRS:S-34 & S-23 or latest. The interlocking code for this unit shall be ""ABCDE"". Inspection authority:- RDSO Inspection charges:- Bornee by Railways Payment Terms:- 100% after supply. | — | — | — | 39,435.6 | |
| — | 10.00 | — | — | ||
| Supply of Q-Series Neutral Line Relay (QN1 Type ), 8F/8B, 24V DC complete with plug board(base plate), connectors and retaining clips etc and conforming to BRS- 930 and RDSO Specn.No.IRS:S-34 & S-23 or latest. The interlocking code for this unit shall be ""ABCDF"". Inspection authority:- RDSO Inspection charges:- Borne by Railways Payment Terms:- 100% after supply. | — | — | — | 37,893.7 | |
| — | 10.00 | — | — | ||
| Supply of Q-Series Twin Neutral Line Relay(QNN1 Type), 6F/2B, 24V DC complete with plug board(base plate), connectors and retaining clips etc and conforming to BRS-960 and RDSO Specn.No.IRS:S-34 & S-23 or latest. The interlocking code for this unit shall be ""ACDEK"". Inspection authority:- RDSO Inspection charges:- Borne by Railways Payment Terms:- 100% after supply. | — | — | — | 49,853.3 | |
| — | 10.00 | — | — | ||
| Supply of Q-Series Magnetically Latched Neutral Line Relay (QL1 Type), 11F/4B,24V D C complete with plug board(base plate), connectors and retaining clips and conforming to BRS- 935A and RDSO Specn.No.IRS:S-34 & S-23 or latest.The interlocking code for this unit shall be ""ABDEG"". Inspection authority:- RDSO Inspection charges:- Borne by Railways Payment Terms:- 100% after supply. | — | — | — | 57,014.5 | |
| — | 10.00 | — | — | ||
| Supply of Q-Series Neutral Line Relay(QSPA1 Type), 24V DC,8F/4B along with plug board (base plate), connectors, retaining clips etc and conforming to BRS-933A and RDSO Specn.No.IRS:S@ 45"44@ S-23 & S 60 or latest.The interlocking code for this unit shall be ""ABDEJ"". Inspection authority:- RDSO Inspection charges:- Borne by Railways Payment Terms:- 100% after supply. | — | — | — | 52,112.7 | |
| — | 10.00 | — | — | ||
| Supply of Contactor Unit (QBCA1 Type), 24 V DC, 2HF/4B complete with plug board(base plate), connectors, retaining clips etc and conforming to BRS- 943 and RDSO Specn.No.IRS:S-34 & S-23 or latest.The interlocking code for this unit shall be ""BCEJK"". Inspection authority:- RDSO Inspection charges:- Borne by Railways Payment Terms:- 100% after supply. | — | — | — | 70,800 | |
| — | 200.00 | — | — | ||
| Termination of Outdoor Cables (Main Cables /tail cables) at both ends in location boxes, cable termination rack in relay room, station building, generator room etc. The item includes dressing of cables and wires with dressing threads as per standard practice. All material required for this item will be supplied by contractor. The outdoor cable shall be terminated in Relay Room, DG Room, ASM Room etc under supervision and instructions issued by Engg. incharge of the work. Inspection: Consignee Inspection Charges: None Payment Terms: 100% after execution | — | — | — | 1,692 | |
| — | 30.00 | — | — | ||
| Supply of uncharged Low Maintenance Lead Acid (LMLA) secondary cell, shelf mounting type conforming to RDSO Specn.No.IRS:S-88/2004 or latest with inter cell connectors, nuts and bolts etc. Inspection: RDSO Inspection Charges: Borne by Railways Payment Terms: 100% after Supply. 2V, 80 AH | — | — | — | 62,037.9 | |
| — | 30.00 | — | — | ||
| Charging of Lead Acid Batteries with contractors own battery grade sulphuric acid and distilled water with minimum two charge - discharge cycles, installation of charged batteries in groups & their connection & wiring. The work shall be done as per extant practice of N.W.Rly & instruction of Engineer-in-charge. Detailed measurements of initial charging shall be recorded jointly by contractor & Rly's site-in-charge. Inspection: Consignee Inspection Charges: None Payment Terms: 100% after Execution. 2V 80AH | — | — | — | 11,130.6 | |
| — | 2.00 | — | — | ||
| Fixing, wiring, testing and commissioning of Electrical Point Machine on the extended sleepers at points as per std. practice and as per RDSO Drg No. SA 9151-52 or 9710 or 9161 or 10800 or 11000 as per section of rails used. Item includes fixing switch extension bracket, providing insulation for switch extension bracket, fixing ground connection, adjusting opening of the switches and adjusting the point machine with crank handle.The item also includes : (i)Complete material for installation like ground-connections, switch extension brackets, point insulation material, I pipes, wiring materials, various fixing nuts & bolts including castle nuts, spring washers (ii) All smithy & fitting works required at site for complete installation. (iii) Installation of gauge tie plate & providing insulation for gauge tie plate (Insulation in William Stretcher Bar will be Provide by Railways). (iv) Wiring inside the point machine, insertion and termination of tail cable in point machine and junction boxes / location box /cable hut as per extent practice on NWR and the instruction of Railway Engineer at site. (v) Supply and fixing of suitable size GI pipes with flange for taking cable into point machine. Note ; The ground connections shall be suitable to the Point Machines as specified by Engineer-in-charge and shall be suitable to the point lay out i.e. 60 Kg. / 52 Kg / 90R as per yard layout. Electrical Point Machine and M-6 / Screw less terminals will be supplied by Railways / covered in Schedule separately Inspection: Consignee Inspection Charges: None. Payment Terms: 100% after Commissioning. | — | — | — | 55,172.02 | |
| — | 5.00 | — | — | ||
| Supply of Track feed Battery Charger as per RDSO Specn. No.IRS: S-89/2013 Ver.1.0 or latest. Charging Capacity Rating 10 Amps for Charging 80 AH Battery. Inspection: RDSO Inspection Charges: Borne by Railways Payment Terms: 100% after Supply. | — | — | — | 22,525.6 | |
| — | 5.00 | — | — | ||
| Supply of Adjustable Track Feed Resistance 30 Ohms (Disc Type) as per RDSO Drg. No.SA-20161-66/M or latest. Inspection: Consignee Inspection Charges: None Payment Terms: 100% after Supply. | — | — | — | 7,195.85 | |
| — | 5.00 | — | — | ||
| Fixing and wiring of DC track circuit equipments i.e. track feed charger, resistance, track relay, battery, B type choke etc., in the Apparatus Case and battery box as per standard practice. Termination of tail cable on M 6 / Screw less terminals WAGO or FINOLEX or similar approved make teminals/ fuse blocks / HRC fuse. Item includes testing /commissioning of track circuit. Complete wiring material will be supplied by contractor. (Supply of Track feed battery charger, track feed battery, resistances & 'B' type choke & Track relays, ARA terminal/Modular terminals wago/phoenix contact type will be supplied by Railways / covered in Schedule separately). Inspection: Consignee Inspection Charges: None Payment Terms: 100% after execution. | — | — | — | 31,770.05 | |
| — | 5.00 | — | — | ||
| Installation of DC track circuits covering all types of Track circuts including points zones also.The item includes provision of doubled continuity GI wire bonds on rail joints after drilling bond-hole of 7.0/7.2mm dia, skimming of fish plate, insertion of insulated block joint( if required), fixing of TLJB (separate for positive & negative rails) with angle iron for track feed/jumper/track relay ends of track circuits and also for fixing jumper cables as per approved Track Circuit Plan, making rail connections through suitable insulated sleeves from TLJB at TF, jumper & TR end with GI wire, rail clips for fixing bond wire on the TLJB as per standard practice, termination of tail cables on TLJB terminals etc. TF/TR wiring shall be fixed on the suitable arrangement on PRC sleepers with the help of Hooks. In case Engineer at site desires that jumpering from TLJBs is to be done using signalling cable 2 coreX 2.5 sqmm , contractor shall provide the jumpering cable using 2 X 2.5 sqmm signalling cable.The signalling cable will be supplied by Railways. Hooks shall be provided on PRC sleepers with the help of suitable steel bracket. This item also includes fixing & supply of channel pins, Hooks etc. The item does not include includes supply of TLJB as per RDSO Drg.No.RST-11509 or latest as per technical specs Installation of of Track Lead Junction Box(TLJB) as per Drg.No.RST-11509 or latest made from FRP material including brass bolts and hylam board sheet with terminals etc. (a) Installation and commisssioning of TLJB complete with cover to be in black/red having approximate weight of 4.0 Kg with L-262mm W-212mm and H 90 mm and all the holes required for mounting on FRP stump (verticall two for each FRP angle) HDPE pipe , cable etc. (b) Installation and commisssioning of Each TLJB having two bakellite terminal block fitted horizontally : each bakellite terminal block shall have two nickel chrome plate M10 brass terminal, 50mm long.Alongwith each TLJB , nickel chrome plated brass links(two nos.0f adequate strength for vertical linking of the terminals to be wired and fixed properly. (c) Installation of HDPE pipe of size 32/35mm , 380 mm long alongwith two nuts for fixing on the TLJB hole . (d) Installation of the FRP stump for mounting the TLJB to be made of one meter long 30mm X30mmX 4mm angle(2 nos.) and 300mm long 30mm X30mmX 4mm angle(1 no.) fixed at 50 mm from the bottom using galvanised nuts and bolts.The TLJB and the angles for stump should be fixed in given holes on them for fixing using galvanised nuts and bolts . Inspection: Consignee Inspection Charges: None Payment Terms: 100% after execution. | — | — | — | 39,764.5 | |
| — | 30.00 | — | — | ||
| Supply of Track Lead Junction Box(TLJB) as per Drg.No.RST-11509 or latest made from FRP material including brass bolts and hylam board sheet with terminals etc. The technical specifications are as follows: (a) TLJB complete with cover to be in black/red having approximate weight of 4.0 Kg with L-262mm W-212mm and H 90 mm and all the holes required for mounting on FRP stump (verticall two for each FRP angle) HDPE pipe , cable etc. (b) Each TLJB shall have two bakellite terminal block fitted horizontally : each bakellite terminal block shall have two nickel chrome plate M10 brass terminal, 50mm long.Alongwith each TLJB , nickel chrome plated brass links(two nos.0f adequate strength for vertical linking of the terminals to be supplied. (c) HDPE pipe of size 32/35mm , 380 mm long alongwith two nuts for fixing on the TLJB hole . (d) The FRP stump for mounting the TLJB to be made of one meter long 30mm X30mmX 4mm angle(2 nos.) and 300mm long 30mm X30mmX 4mm angle(1 no.) fixed at 50 mm from the bottom using galvanised nuts and bolts.The TLJB and the agles for stump should come alongwith holes on them for fixing using galvanised nuts and bolts of adequate strength to be supplied alongwith TLJB drawing no. 11509. Inspection: (i) RITES if value of item in work more than 5 lakhs (ii) Consignee subject to procurement from RDSO approved vendors if value of whole item in work less than 5 lakhs as per extant instructions by Railway Board. Inspection Charges: (i)Borne by Railways (ii) None Payment Terms: 100% on Supply | — | — | — | 53,352 | |
| — | 10.00 | — | — | ||
| Supply of B Type Choke as per RDSO Specn.No.IRS:S-65/83 (Amnd. 1) or latest. Inspection: RDSO Inspection Charges: Borne by Railways. Payment Terms: 100% after supply. | — | — | — | 40,989.4 | |
| — | 100.00 | — | — | ||
| Supply of Channel Pins MS (Galvanized) single groove, 7 mm suitable for 4mm dia bonding wire as per spec No IRS S 17 & RDSO Drg No. S-69/M. Inspection: Consignee Inspection Charges: None Payment Terms: 100% after Supply. | — | — | — | 569 | |
| — | 2.00 | — | — | ||
| Supply of Position Light Shunt Signal Unit Complete with Post(made of GI Pipe of 80 mm Diameter Medium Class IS Spec. No. IS: 1239 Pt. 1/1990, Base, Hood, Cover etc as per Drg. No. SA-23840 suitable for LED Signal Lighting Unit.(Supply of LED Unit is not covered in this item) Inspection: (i)RDSO/RITES if value of item in work more than 5 lakhs (ii) Consignee subject to procurement from RDSO approved vendors if value of whole item in work less than 5 lakhs as per extant instructions by Railway Board. Inspection Charges: (i)Borne by Railways (ii) None Payment Terms: 100% on Supply | — | — | — | 8,594.94 | |
| — | 2.00 | — | — | ||
| Erection of Position Light Shunt signal with Base, Post, Signal unit and fixing of Number Plates. The work shall be done as per instructions of Rly engineer at site. Inspection: Consignee Inspection Charges: None. Payment Terms: 100% after Commissioning. | — | — | — | 3,559.98 | |
| — | 2.00 | — | — | ||
| Casting of C.C. Foundation for Position Light Shunt Signal/ Indicator/SPI as per Drg.No.CSTE/NWR/SOR/ 22 in ratio 1:3:6 by using standard size of galvanized holding down/foundation bolts. Item includes excavation, ramming of CC using vibrator, curing and plastering with 1:4 cement sand mixture. Aggregate cement, sand and holding down bolts, will be supplied by contractor. Any machines and tools, if required for execution of this item, will be arranged/provided by contractor. Note: As per available site conditions, if sizes of foundations are required to be decreased/ increased and same has been approved/agreed by engineer incharge then variation in CC work will be calculated on volumetric basis as per rates of these items. Inspection: Consignee Inspection Charges: None. Payment Terms: 100% after installation. ." | — | — | — | 12,620.52 | |
| — | 2.00 | — | — | ||
| Installation of Apparatus Cases Single(Large) with 'E' type lock on CC foundation. This includes filling of location foundations with river bed sand and plastering on top of the sand. Supply of 'E' Type lock has been covered in supply of Apparatus case separately. It covers fixing of lamp holder , switch and lamp etc. in Apparatus Case. Inspection: Consignee Inspection Charges: None Payment Terms: 100% after installation. | — | — | — | 2,078.18 | |
| — | 1.00 | — | — | ||
| Installation of Apparatus Cases Half (Medium) with 'E' type lock on CC foundation. This includes filling of location foundations with river bed sand and plastering on top of the sand. Supply of 'E' Type lock has been covered in supply of Apparatus case separately. It covers fixing of Location lamp holder , switch and lamp etc. Inspection: Consignee Inspection Charges: None Payment Terms: 100% after installation. | — | — | — | 632.78 | |
| — | 2.00 | — | — | ||
| Excavation and Casting of Apparatus Case foundation in ratio 1:3:6 with contractor's own materials including cement and galvanized anchor bolts of standard size. The required scaffolding Ferma etc for Casting of foundation will have to be brought by the contractor at his own cost.The item also includes additional masonry work as well as earthwork if required on bank where there will be possibilities of foundation sinked, fallen or tilted. Inspection: Consignee Inspection Charges: None Payment Terms: 100% after installation. Single (Large) Case Apparatus case / SS location box as per Drg No. CSTE/5074 | — | — | — | 13,777.84 | |
| — | 1.00 | — | — | ||
| Excavation and Casting of Apparatus Case foundation in ratio 1:3:6 with contractor's own materials including cement and galvanized anchor bolts of standard size. The required scaffolding Ferma etc for Casting of foundation will have to be brought by the contractor at his own cost.The item also includes additional masonry work as well as earthwork if required on bank where there will be possibilities of foundation sinked, fallen or tilted. Inspection: Consignee Inspection Charges: None Payment Terms: 100% after installation. Half (Medium) Case Apparatus case / SS location box as per Drg No CSTE/5074 | — | — | — | 5,259.16 | |
| — | 2.00 | — | — | ||
| Fabrication and fixing of phenolic laminated sheet of size 10/12/20 mm thick in location box by providing all fixtures as per Railway Drawing including fixing of PVC coated string rods at the back side for cable support with contractor's own materials. The work shall be done as per instructions of Rly engineer at site. Inspection: Consignee Inspection Charges: None Payment Terms: 100% after installation. Single Case (Large Case) | — | — | — | 4,688.98 | |
| — | 1.00 | — | — | ||
| Fabrication and fixing of phenolic laminated sheet of size 10/12/20 mm thick in location box by providing all fixtures as per Railway Drawing including fixing of PVC coated string rods at the back side for cable support with contractor's own materials. The work shall be done as per instructions of Rly engineer at site. Inspection: Consignee Inspection Charges: None Payment Terms: 100% after installation. Half Case (Medium Case) | — | — | — | 684 | |
| — | 200.00 | — | — | ||
| Supply of ARA Terminal Block (M-6) made of PBT/Poly Carbonate as per RDSO Specn.No.IRS:S-75/2006 (Rev.2) or latest and RDSO Drg.No. SA-23741A(Alt. 4) or latest. Inspection: RDSO. Inspection Charges: Borne by Railways. Payment Terms: 100% on supply. | — | — | — | 17,482 | |
| — | 200.00 | — | — | ||
| Fixing of ARA(M-6) Terminals /Screw less connectors / modular disconnect terminal blocks and fuse blocks on phenolic laminated sheets and fixing by stainless steel/brass nuts & bolts. This includes provision of two additional holes on the board on either side for cable conductor entry. (Supply of all above terminals have been covered separately in Chapter 4 of SOR) Inspection: Consignee Inspection Charges: None Payment Terms: 100% after installation. | — | — | — | 2,504 | |
| — | 1.00 | — | — | ||
| Fixing of KLCR relays in field in half location boxes if Gate lodge is not provided or at any other location as decided by engineer in charge. Item includes supply and fixing of MS sheet and wiring of KLCR relays, push buttons and LEDs for KLCR circuit. The KLCR relays, push buttons, LEDs will be fixed on a MS sheet of min. 3mm in the half location box. The MS sheet will cover full length and breadth of the half location box and divided in two pieces of approx. 48cm x 46cm and 80cm x 46cm. The first piece to be fitted on top and will contain the KLCR relays, LEDs and push buttons. The second piece to be fitted below the first piece. (Supply of KLCR relays covered in separate item of SOR). Inspection: Consignee Inspection Charges: None Payment Terms: 100% after installation. | — | — | — | 2,193.2 | |
| — | 1000.00 | — | — | ||
| — | — | — | 31,870 | ||
| — | 200.00 | — | — | ||
| — | — | — | 24,548 | ||
| — | 500.00 | — | — | ||
| — | — | — | 1,37,140 | ||
| — | 6000.00 | — | — | ||
| — | — | — | 54,600 | ||
| — | 1.00 | — | — | ||
| Providing brick masonry in ratio 1:6 cement and mortar including plastering with 1:4 cement and sand mixture both sides, 20 mm thick each with contractor's owned class II bricks, including excavation, curing, grouting, bolting etc. wherever required. Bricks sand and cement to be supplied by the contractor. Inspection: Consignee Inspection Charges: None. Payment Terms: 100% after Execution(Unit is cubic meter) | — | — | — | 1,990.54 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .