Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.1 CrAccepted-AOC C O GUPTA EMPORIUM AR BAZAR HAPPY VALLEY SHILLONG 793 004 | EAST KHASI HILLS | MEGHALAYA | 793004 | ₹4.1 Cr Quoted ₹4.2 Cr | L1 | Accepted-AOC Lowest Bidder M/S UTTAM SAHA |
| 2 | L2₹4.4 Cr+₹22.1 L (5.30%)Rejected-Finance 7TH MILE UPPER SHILLONG P O NONGLYER SHILLONG MEGHALAYA | EAST KHASI HILLS | MEGHALAYA | 793009 | ₹4.4 Cr+₹22.1 L (5.30%) | L2 | Rejected-Finance Other than Lowest Bidder |
| 3 | L3₹4.5 Cr+₹29.3 L (7.02%)Rejected-Finance | ₹4.5 Cr+₹29.3 L (7.02%) | L3 | Rejected-Finance Other than Lowest Bidder |
| 4 | L4₹4.9 Cr+₹75.2 L (18.0%)Rejected-Finance H M APARTMENT FLAT NO 5C SJ ROAD ATHGAON GUWAHATI 781001 ASSAM | KAMRUP METRO | ASSAM | 781001 | ₹4.9 Cr+₹75.2 L (18.0%) | L4 | Rejected-Finance Other than Lowest Bidder |
Tender Value
₹4.6 Cr
EMD Value
₹5.4 L
Closing Date
12 Sept 2024, 6:00 pmClosed
Cheif Engineer Shillong
HQ Cheif Engineer Shillong zone Spread Eagle falls-793011
ADDITION/ ALTERATION TO JCO/OR MD ACCOMMODATION AT UMROI UNDER GE UMROI
2024_MES_660748_1
CESZ/UMR/ of 2024-2025
Open Tender
Civil Works
Item Rate
450 days
GE Umroi
As per NIT
2 documents required · 2 mandatory
₹2,000
GE Umroi
₹5.4 L
Yes
27 Sept 2024
19 Jun 2024
14 Sept 2024
19 Jun 2024
12 Sept 2024
26 Jul 2024
Amount
Dismantling of floor hearth or wall tiling including cement mortar bedding ( but not backing) and removing debris and rubbish off the premises complete all as specified and directed.
Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust and brushing neat cement slurry with 3kg of cement per sqm complete all as specified and directed.
M&L for Non - skid coloured Ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15 mm thick screed bed or bedding layer in CM (1:6) complete all as specified and directed.
M&L for Non - skid coloured Ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, as in skirting etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 10 mm thick rendering in CM (1:4) complete all as specified and directed.
M&L for colured Glazed ceramic tiles in vertical surface 375 x 250 x 7 mm / 450 x 300X 7mm thick set and jointed in neat cement slurry and pointed in colour cement to match over and including 10 mm thick rendering in CM (1:4) complete all as specified and directed.
M&L for machine cut kota stone slab flooring 20-25mm thick over and including 20 mm thick cement screed base in CM (1:6) laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing, polishing and treating the surface with beeswax polish complete all as specified and directed.
M&L for machine cut kota stone slab 20-25 mm thick in riser of steps, skirting, dado and pillar over and including 20 mm thick rendering in CM (1:4) laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing, polishing and treating the surface with beeswax polish complete all as specified and directed.
M&L for 20 mm thick Granite (of any type) work ( table rubbed and polished) in steps, jambs, pillars,window cills, cooking platforms and like, over and including in 15 mm thick bedding layer of cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed.
Taking down chowkats or frames exceeding 1.5 SQM but not exceeding 4 SQM in each (without taking off shutters from the frame) complete all as directed.
Taking down chowkats or frame with shutters (without taking off shutters from frame) each not exceeding 1.50 Sqm complete all as directed.
Taking down shutter of any description exc 1 sqm but nexc 2 sqm each complete all as directed.
Refixing shutters of any description exc 1 sqm and n exc 2 sqm each in same opening complete all as directed.
S&F PVC door frame of size 50mmx47mm made out of 5mm wood grain printed single side pre laminated PVC sheet used reinforced with MS square tube complete all as specified and directed.
S&F factory made pre-painted wood grain powder coated 105 x 60 x 1.25 mm pressed steel frame for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc complete all as specified and as directed. Note: PCC for filling the hollow portion of frame shall be measured and paid separately under respective item.
S&F factory made pre-painted wood grain powder coated 125 x 60 x 1.25 mm pressed steel frame for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc complete all as specified and as directed. Note: PCC for filling the hollow portion of frame shall be measured and paid separately under respective item.
S&F cold rolled mild steel butt hinges 100 mm long medium weight complete all as specified and as directed.
S&F cold rolled mild steel butt hinges 75 mm long medium weight complete all as specified and as directed.
S&F continuous (Piano) hinges, mild steel, bright finished or electro galvanized of width of flaps 30 mm (When open) complete all as specified and as directed.
M&L for plain cement concrete (1:2:4) type B0 using 12.5 mm graded crushed stone aggregate as in hold fast block / bed block/ filling in pressed steel door frame etc complete all as specified and as directed.
M&L for MS bands, straps, supports or stays for pintle hinge, hand made sliding bolts, hold fast etc conforming to Fe-290 Gde-E-165 complete all as specified and as directed.
S&F 35 mm thick factory made 2nd class hard wood plain framed panelled shutters (02 number of panels) with lock rails and panels of 12 mm veneered particle board with commercial veneering on both faces complete all as specified and as directed. Note: The size of rail and stile shall be as per IS 1003 (Part I), and the same shall be kiln seasoned and chemically pressure treated.
S&F 35 mm thick factory made 2nd class hard wood glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc, (with sash bars), edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass,etc, sizes of members of shutters as specified in SSR Part -I. section 8, clause 8.24(a) complete all as specified and as directed.
M&L for preparation of new or previously untreated surfaces of wood and wood based surfaces of any description, not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed.
M&L for preparation of old painted wooden surfaces of any description over 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed
M&L for Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; but wire gauzed i.e panel will be of wire gauze in lieu of single side prelam PVC sheet panel. The wire gauze shall be wrapped on an additional square 8 mm MS solid tube and this tube shall be welded to MS tube. The wire gauge shall be stretched to tighten firmly complete all as per specification & drawing No. 08093 of SSR Part II Page No. 179. Note: The cost of builders hardwares required for this item are included in the quoted rate of this item.
M&L for 18mm thick WPC (wood plastic composite) material including 1.5mm thick acrylic laminated colour and pattern as approved fixed with adhesive as per manufacturer’s instruction complete all as specified and as directed. Note: (i) Rate is inclusive of fixing of approved builder hardware as per standered engineering practice (ii) Colour and texture shall be approved by GE.
S&F wood grain walnut colour power coated Aluminium (Minumium thickness of powder coating 50 micron) work for doors, windows, ventilators and partitions (Fixed portions) for structural glazing with extruded builtup standard tubular sections / appropriate Z sections and other sections of approved make conforming to IS 733 and IS 1285 , fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions i.e at top, bottom and sides with required EPDM rubber / neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, metered and jointed mechanically wherever required including cleat angle, aluminium snap beading for glazing/ panelling , CP brass/ stainless steel screws complete all as specified and as directed.
S&F wood grain walnut colour, powder coated of any colour Aluminium window and ventilator shutter sliding type, aluminium sections weighing 0.55kg including necessary jointing cleats, glazing clips, rubber packing, aluminium anodised snap beading screws, aluminium anodised fittings such as peg stays 150 mm long 01 No, 150 mm long hinges 02 Nos B-21 type and 01 No handle of required size complete all as specified and as directed.
M&L for aluminium anodised grill (Anodised transparent or dyed to required shade according to IS 1868) with minimum anodic coating of grade AC 15 of approved design / pattern with approved standard section and fixed to the existing window frame with CP brass / stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening complete all as specified and as directed.
S&F 4 mm thick tinted glass, of superior quality and glazing with oil putty or aluminium beads in square/ rectangle exceeding 0.50sqm in each pane complete all as specified and as directed.
S&F 4 mm thick figured glass, pin headed type and glazing with oil putty or aluminium beads in square/ rectangle not exceeding 0.50sqm in each pane complete all as specified and as directed.
S&F stain less steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with tinned tacks or aluminum wire staples complete all as specified and as directed.
S&F 150 mm in size aluminium alloy handles, fabricated type, anodisedcomplete all as specified and as directed.
S&F 150 mm in size aluminium anodised barrel tower bolt complete all as specified and as directed.
S&F 200 mm in size aluminium anodised barrel tower bolt of extruded section complete all as specified and as directed.
S&F aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolt of extruded section or cast aluminium alloy and fixed 300 mm long complete all as specified and as directed.
S&F 100 mm aluminium anodized hasp and staple, safety type with mild steel hinge pin including bolt to hinge plate and fixed with screws complete all as specified and as directed.
S&F mild steel helical door spring of size 300 mm including roller and roller plate complete all as specified and as directed.
Dismantling of wall and ceiling boards (fibre, pulp, insulation etc) or insulation boards/slabs of any thickness including cover fillets complete all as specified and as directed.
M&L for aluminium anodised snap grid frame work for false ceiling including hangers 6 mm dia GI wire up to 1200 mm length , adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40 x 3 mm size 60 mm long and expansion hold fasteners 12.5 mm dia 40 mm long complete all as specified and as directed.
S&F decorative PVC ceiling board of superior quality of size 600mm x 600mm x 5mm thick fixed in aluminium snap grid frame work including fixing accessories complete all as specified and as directed. Note: (I) Frame work shall be measured and paid separately under respective item. (II) Colour and design PVC ceiling board shall be approved by GE.
S&F in repair 20 mm dia decorative type tubular curtain rod brass chromium plated complete all as specified and as directed.
S&F in repair decorative brackets for tubular curtain rod complete all as specified and as directed.
Taking up or down 15mm bore GI tubing and connections including cleaning for re-fixing or removal to store complete all as specified and as directed.
All as per serial item No. 44 above but for 20 mm bore pipe
All as per serial item No. 44 above but for 25 mm bore pipe
S&F CPVC pipe 16mm outer dia of SDR, fixed to walls and ceilings or floors etc (concealed pipe work) upto 4 storey high building complete all as specified and as directed. Note: Rate is included for cutting chases in wall / ceiling / floor etc and their making good.
S&F CPVC pipe 20 mm outer dia of SDR 11 plain CPVC SDR 11 fittings as in wall, ceiling, floor etc up to 4 storey height of building complete all as specified and as directed.
All as per serial item No. 48 above but for 25 mm outer dia of pipe
S&F 1000 ltrs capacity rotational moulded polyethylene water storage tanks (Cylindrical verticle with closed top) hoisted and fixed in position all as specified in SSR Part I complete all as specified and as directed.
S&F in repair PVC ball valve 20 mm high pressure of PTM with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe complete all as specified and as directed.
S&F in repair kitchen sink made out of 1mm thick sheet of overall size 495 mm x 420 mm bowl size 410 mm x 330 mm x 160 mm with plug washer, brackets, connecting union, 40 mm dia waste pipe and 40 mm waste coupling complete all as specified and as directed.
S&F in repair PVC valve less syphonic action flushing cistern 10 ltrs capacity with inlet, ball valve, float and handle including bracket, PVC connection and flush pipe 32 mm dia , white colour complete all as specified and as directed.
Up rooting of tree from walls of bldgs up to extended root and spraying of acid of required quantity complete from any location of Bldg up to 4 storied and making good disturbed surfaces with cement mortar (1:4) or cement concrete (1:3:6) type C1 using 20 mm graded crushed stone aggregate for tree of girth up to 10 CM , area exc 1 Sqm but n exc 2 Sqm complete all as specified and as directed. Note : Cost of necessary scaffolding included in quoted rate.
S&F in repair vitreous china squatting pan of Orissa pattern size 580 mmx440 mm white with P or S trap front or back inlet and integral foot rest ( Excluding flushing cistern and flush pipe) complete all as specified and as directed.
S&F in repair wash hand basin, white flat back of size 550 x 400 mm excluding piller taps but including waste coupling, PVC connection, waste pipe and bracket complete all as specified and as directed.
S & F brass chromium plated wall mixer for mixing of hot and cold water screwed down for CPVC SDR-11 pipe of outer dia 20mm complete all as specified and as directed.
S&F in repair 15 mm dia fancy type pillar tap cast copper alloy, chromium plated, screwed down high pressure with or without lettered Hot or Cold with long screwed shanks and fly nuts, screwed for iron pipe complete all as specified and as directed.
S&F in repair stop valve 15 mm dia CP fancy type, with long shank and cup (concealed type) cast copper alloy, screwed both ends for iron pipe or for unions complete all as specified and as directed.
S&F in repairs of stop valve/Angle cock 15 mm dia CP fancy type, with long shank and cup cast copper alloy, screwed both ends for iron pipe or for unions complete all as specified and as directed.
S&F in repair Shower Rose 125 mm size Chromium plated with swivel joints, any size, including fixing to steel pipe or union complete all as specified and as directed.
S&F in repair Bib tap 15 mm bore long/short body,chromium plated with crutch or butterfly handle, screwed for iron pipe or for brass ferrule complete all as specified and as directed.
S&F in repair utensil rack/kitchen rack stainless steel size 850 mm x 800 mm x270 mm and fixed to wall complete all as specified and as directed.
Dismantling plain or corrugated steel sheeting any gauge , thickness, including Nainital or similar pattern coverings complete all as specified and as directed.
Fixing only plain or corrugated steel sheet of any guage or thickness as obtained from dismantling item and shall be fixed with new 'L' or 'J' type hooks or cranked hook bolts in roof complete all as specified and as directed.
S&F coloured roof sheet Pre- painted galvalume aluminum zinc coating PPGL based corrugated/Trapezoidal steel sheet 0.50 mm thick of any colour having tensile strength 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws, complete all as specified and as directed.
S&F Pre- painted galvalume aluminum zinc coating PPGL based plain steel sheet 0.60 mm thick of any colour having tensile strength 550 Mpa as in roof covering/cladding to wall, eave board, fixed with self tapping screws, complete all as specified and as directed.
S&F half round colour coated UPVC gutter/runner drop for rain water drain in bldgs of size not exceeding 150 mm with firmly attached downpout of suitable size discharging storm water into PVC SWR pipe of 110 mm dia and similar works etc complete all as specified and as directed. Note: the rate shall be inclusive of downpouts, drop outlet, Elbow, End cap, Straight connecter, brackets, downspout couple, splash block, out site corner, clamps as required at site as per standard Engineering practice.
M&L for Preparation of old steel and iron surface of any description over 10 cm wide or girth and applying one coat of synthetic enamel paint complete all as specified and as directed.
Demolition of Concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) using concrete cutter complete all as specified and as directed.
M&L for taking down of existing roof treatment from roof and terrace, by roughening surface of old concrete roof picking, sweeping clean and washing down with water to remove dust, etc and applying roof treatment with the following steps and specifications:- a) Applying crack seal compound of same manufacturer of water proof to fill all cracks observed on the roof. b) Applying cement slurry over concrete surfaces @3kg/sqm. c) Rendering 15 mm thick in cement mortar (1:4) mixed with water proofing compound as per manufactures’ instruction(not less than 3% by weight of cement) on cleaned concrete surface of roof and finishing the surface fair and even including curing the plastered surface for 7 days by ponding of water over the roof, (leveling course). d) Applying evenly one coat of primer coating (diluted with water in the ratio specified by Manufacturers) (min @100-110sq Ft per liter (diluted quantity)) on the cleaned plastered surfaces. The surface shall be left for air dry for minimum period of 2-3 Hrs. e) Applying evenly one coat of elastomeric water proof coat in one direction (as specified by Manufacturers)(min@ 0.9-1.0 sqm per ltrs) and allow to air dry for 4-6 hrs before applying second coat in other direction perpendicular to the first one (as specified by Manufacturers) (min @0.9-1.0 Sqm per ltrs. The total thickness of two coats shall be 0.5 to 0.6 mm. f) The whole system shall be left to air for curing for min Seven days (without any movement). Note : - (i) The waterproofing shall be carried out in the last stage of execution to avoid any damages during the execution. (ii) Payment against this item shall not be allowed till completion of all the stages of work for any slab. (iii) The work shall be executed through Authorized well-trained applicators as per manufacturer’s instructions after obtaining written approval from the GE
Demolition of brick work built in CM including all quoins,arches,pillars etc complete all as directed.
M&L for brick work with subclass 'B' bricks straight or curved on plan exc. 6 m mean radius built in CM (1:6) complete all as specified and as directed.
M&L for Brickwork with sub-class `B’ bricks, straight or curved on plan to any radius in half brick thick walls built in CM (1:4) .(upto 04 storey High of building) complete all as specified and as directed.
M&L for 15 mm thick rendering in CM (1:4) in two layers mixed with liquid water proofing compound as per manufacture instruction in top layer 5 mm thick finishing the surfaces with fair and even without using extra cement complete all as specified and as directed. Note: Liquid water proofing compound shall be measured and paid separately under respective item.
M&L for 15 mm thick rendering in CM (1:4) in two layers mixed with liquid water proofing compound as per manufacture instruction in top layer 5 mm thick finishing the surfaces with fair and even without using extra cement including Taking down of cement plaster of any description including racking out joints for key scrubing with watercomplete all as specified and as directed. Note: Liquid water proofing compound shall be measured and paid separately under respective item as supply only.
Supply only liquid WPC ( Integral waterproofing liquid admixture for cement mortar) and application as per manufacture instruction complete all as specified and as directed.
M&L for rendering 15 mm thick in cement mortar (1:6) internal surfaces other than fair faces of brick work or concrete surfaces making finished even and smooth without extra cement complete all as specified and as directed.
M&L for rendering 15 mm thick in cement mortar (1:6) internal surfaces on other than fair faces of brick work or concrete surfaces,making finished even and smooth without extra cement including Taking down of cement plaster complete all as specified and as directed.
M&L for 5 mm thick rendering in cement mortar (1:3) on fair faces of exposed/non exposed concrete surfaces such as soffits of slabs, chajja, fasia and simillar work in patches n exc 1 Sqm including mixing & application integral water proofing compound as per manufacture instruction. Finishing the surfaces fair and even including Taking down of cement plaster of any description including racking out joints for key scrubing with water complete all as specified and as directed.
M&L for preparing new plastered surfaces of wall and applying two coats of oil bound distember white or tinted over a coat of white primer complete all as specified and directed.
M&L for preparing surfaces of newly plastered surface of walls and finishing wall surface with acrylic smooth exterior paint of required shade : New Work ( Two or more paint layer to be applied @1.67 ltr/10 Sqm over and including priming coat.) complete all as specified and as directed.
M&L for three coats of white wash on newly plastered surfaces of ceiling including preparation of new plastered surface complete all as specified and as directed.
M&L for two coats of white wash on old surfaces of wall including preparation of old plastered surfaces complete all as specified and as directed.
M&L for complete removal of existing treatment and applying two coats of oil bound distember on wall over a coat of primer complete all as specified and as directed.
M&L for complete removal of existing treatment on wall and finishing walls with acrylic smooth exterior paint of required shade : New Work ( Two or more paint layer to be applied @1.67 ltr/10 Sqm over and including priming coat.) complete all as specified and as directed.
M&L for complete removal of existing treatment and applying three coats of white wash on the surfaces of ceiling complete all as specified and as directed.
M&L for complete/Partial removal of loose/ cracked RCC including cutting of reinforcement from RCC roof projection, chajja, fins, facia etc complete all as specified and as directed. Note:- (i)The rate shall be inclusive of Scaffolding if required up four storey.
M&L for RCC (1:1.5:3) type A0 (using 12.5 mm graded crushed stone aggregate) and applying bonding agent as per manufacture instruction and making good to match with the undisturbed portion in any position finished the surface even and smooth with out using extra cement including necesary welding/binding of reinforcement if required, complete all as specified and as directed.
Use and waste of form work to chullah hoods, chajjas, troughs and similar items including edges for smooth finishes complete all as specified and directed.
M&L for Mild steel TMT bars 5 mm to 10 mm dia., cut to length, bent to shape required, in stirrups, spacers and binders and binding with mild steel wire (annealed) not less than 0.9 mm dia., or securing with clips complete all as specified and as directed.
M&L for welded steel wire febric not exceeding. 4 Kg/Sqm supplied and fixed to RCC member including necessary welding and binding with mild steel wire (annealed) not less than 0.9 mm dia, or securing with clips , over Guniting/plastering in CM 1:4 average 20 mm thick incl water proofing admixtures compound as per manufacturer instructions, finishied even and smooth using extra cement to level the surface etc of over head tanks/UG Sumps where required complete all as specified and as directed. Note: (i)The Cost of Scaffolding included in quoted Rate.
Demolition of plain cement concrete of any description and in any position not otherwise specifically provided for complete all as specified and as directed.
M&L for treatment of sunken floor of Toilet/Bathroom in following steps: (i) Top of RCC slab in sunken portion including peripheral beams shall be plastered with 15 mm thick in cement mortar (1 : 3) using approved water proofing compound @ 3% by weight of cement finished even and smooth using extra cement, curved at the junctions. (ii) Apply two coats of epoxy resin/polymer modified cementations coating like brush bond of FOSROK/SIKA/Pedilite or equivalent in list of make both on floor & beams. (iii) Sunken slabs to be given 1:20 slope outward to 25 mm GI pipe spout with 300 mm projection beyond outer surface of wall shall be provided. (iv) Water tightness of sunken portion to be tested by ponding with water for 72 hours. In case of even a slight mark of seepage, the portion to be treated and ponding test shall be carried out again to confirm the water tightness of sunken slab. Note : No cutting in roof slab/beam shall be allowed for passing of CI pipes & fittings.The stage of water proofing to sunken slab shall be passed by GE.
Removing demolished material upto a distance exceeding 250 m but not exceeding 500 m complete all as specified and as directed.
M&L for PCC (1:5:10) Type E2 (using 40mm graded crushed stone aggregate) as in filling sunken floor complete all as specified and as directed.
Taking down soil pipe/ rainwater pipes (any size or pattern ) , including all fittings, heads, shoes, bends, swan-necks,etc. including cleaning or refixing (measured overall as fixed along the centre line over fitting and accessories) complete all as specified and as directed.
S&F 110 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to wall including scafolding etc complete all as specified and as directed.
S&F 75 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to wall including scafolding etc complete all as specified and as directed.
S&F 110 mm dia PVC bend with access door fixed with rubber ring complete all as specified and as directed.
S&F 75 mm dia PVC bend with access door fixed with rubber ring complete all as specified and as directed.
S&F 110 mm dia PVC 'T' with access door fixed with rubber ring complete all as specified and as directed.
S&F 75 mm dia PVC 'T' with access door fixed with rubber ring complete all as specified and as directed.
S&F 75 mm dia PVC(SWR) floor trap with grating including jointing with solvent complete all as specified and as directed.
S&F 110 mm dia PVC(SWR) pipe single socketed in any length with rubber ring joints, laid in trench or on floors including stack and clamp complete all as specified and as directed.
S&F in repairs Brass chromium plated tubular towel rail, 20 mm dia, D type, 60 cm long between flanges complete all as specified and as directed.
Cutting chases, pinning in, making good to facings where required and pointing in cement mortar (1:3) to ends or edges of landings, steps, cills, sunshades, shelves, lintels etc., and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exceeding 20 cm girth in brick walls complete all as specified and as directed.
M&L for 25 mm thick PCC (1:2:4) Type B-1 ( using 20 mm graded crushed stone aggregate) as in floor complete all as specified and as directed.
M&L for 75 mm thick cement concrete (1:3:6) type C2 using 40 mm graded crushed stone aggregate as in plinth protection finished fair and even with using extra cement complete all as specified and as directed.
M&L for cement concrete (1:3:6) type C2 using 40 mm graded crushed stone aggregate as in surface channels and drains, complete all as specified and as directed.
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement including forms, moulds, mitred/stopped ends etc, complete all as specified and as directed.
M&L to repair by rendering 10 mm thick in CM (1 : 3) on chajjas, facia, roof projection, column sides, beam bottom and sides including throating after removing cracked plaster and concrete including cleaning of visible reinforcement and treating with cement slurry also necessary repair to cracked concrete if any with cement concrete (1:2:4) Type B-0 using 12.5 mm graded crushed stone aggregate including necessary scafolding for double/single storey bldgs complete all as specified and as directed.
Demolition of reinforced cement concrete (water tank, RCC jallies or similar item ) using concrete cutter machine of any description and in any position not otherwise specifically provided, separating and staking old reinforcement bar and removal of spoils/ demolished materials not exceeding 50m and depositing and making site clean complete all as specified and as directed.
M & L for 2nd class hardwood, weather boarding, clean sawn, plain, 25 mm thick and 225mm wide (V joint to give 20mm laps) including taking down old decoyed boarding complete all as specified and as directed. Note: (I) Rate inclusive of two coat of synthetic enamel paint over a coat of pink primer. (ii) The rate inclusive of scaffolding work upto 14 metre height.
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit and making good disturbed surfaces of walls, floors, complete all as specified and as directed.
M&L for concealed point wiring with PVC insulated unsheathed multistranded FRLS copper conductor in PVC conduit with cable 1.5 Sqmm size 1100 volts grade conforming to IS:694 and terminate to flush box of required size suitable mounting modular switches and sockets including single core multi stranded FRLS copper conductor 1.5 Sqmm PVC insulated cable as earth wire connected to earth and common earth dolly drawn in same concealed conduit for one light point controlled by one No, one way 6 Amp switch complete all as specified and as directed.
All as per serial item No. 117 above but for one fan/exhaust point controlled by one No, one way 6 Amp switch.
All as per serial item No. 117 above but for one light point controlled by two way 5 Amp switches1
All as per serial item No. 117 above but for one bell/buzzer point controlled by one bell push.
All as per serial item No. 117 above but for one three pin 5 Amp socket outlet point controlled by one No, one way switch on same board.
All as per serial item No. 117 above but for one three pin 5 Amp socket outlet point controlled by one No, one way switch on independent board.
M&L for concealed point wiring with PVC insulated unsheathed multistranded FRLS copper conductor in PVC conduit with cable 2.5 Sqmm size 1100 volts grade conforming to IS:694 in new metal flush box of 1.6 mm thick including one coat of syenthetic enamelled black paint with new modular white cover plate with frame of suitable size of required colour fixed with brass screws and cup washers including single core multi stranded FRLS copper conductor 2.5 Sqmm PVC insulated cable as earth wire to common earth and connected to earth dolly and earth terminal box drawn in same concealed conduit for One 3 Pin socket 15A Indepentent board complete all as specified and as directed.
M&L for concealed point wiring with PVC insulated unsheathed multistranded FRLS copper conductor in PVC conduit with cable 4.0 Sqmm size 1100 volts grade conforming to IS:694 in new metal flush box of 1.6 mm thick including one coat of syenthetic enamelled black paint with new modular white cover plate with frame of suitable size of required colour fixed with brass screws and cup washers including single core multi stranded FRLS copper conductor 4.0 Sqmm PVC insulated cable as earth wire to common earth and connected to earth dolly and earth terminal box drawn in same concealed conduit for Modular AC Box Metal box, power socket Indepentent board complete all as specified and as directed. Note for serial item No. 117 to 124: (i) The cost of cutting chases for concealed conduit wiring and making good in cement mortar is deemed to be included in unit quoted rate for these item. (ii) The cost of flush box is not included in these item and the same shall be measrued and paid under respective item.
S&F Modular switch 1 way 6A, 1 module with red indication, single pole one way, ISI marked complete all as specified and as directed.
S&F bell push, modular type,1 Module 5 amps complete all as specified and as directed.
S&F switch 6 Amps modular type, 1 Module with red indication,single pole, two way 5/6 amps complete all as specified and as directed.
S&F modular socket 6 Amps, 5 pin combined modular type 2 Module, shuttered type, ISI marked complete all as specified and as directed.
S&F modular socket 6/16 Amps 6 pin combined modular type 2 Module, shuttered type , ISI markedcomplete all as specified and as directed.
S&F switch 16 Amp rating Modular type, 1 Module, one way switch complete all as specified and as directed.
S&F Modular cover plate with frame & flush box of 8 modules, complete all as specified and as directed.
S&F Modular cover plate with frame & flush box of 6 modules, complete all as specified and as directed.
S&F Modular cover plate with frame & flush box of 4 modules, complete all as specified and as directed.
S&F Modular cover plate with frame& flush box of 3 modules, complete all as specified and as directed.
S&F Modular cover plate with frame & flush box of 2 modules, complete all as specified and as directed.
S&F Modular cover plate with frame & flush box of 1 module, complete all as specified and as directed.
S&F ceiling rose 3 terminal / PVC insulated body ISI Marked complete all as specified and as directed.
S&F call bell ding dong, AC, 230 V, Single pole ISI marked complete all as specified and as directed.
supply installation, testing & comissioning in repairs intregral LED 4ft luminaire of CRCA / extruded aluminium housing and PC diffuser (Diffuser-Non yellowing type). The luminaire should have a 20 Watt LED with colour consistency SDCM< 5,CRI> 80 and colour temperature - 4000 to 6500K, Luminaire shall be designed to emit at least 2000 nominal lumens at a system efficacy of at-least 120 lumen/watt, power consumption should not be more than 18W (+5%). the life of fixture (including Driver): 50000 burning Hrs.@ L70B50 Lumen maintenance @ design ambient temp 50 deg C. The electronic driver used shall have a power factor >0.95 and THD < 10% suitable for an operating voltage range of 150-270V AC current Ripple<5% internal surge protection should be minimum 2.5KV, electrical insulation class should be Class I &driver should be of class B serviceability. The luminaire should be at least IP20 & IK02 rated. The luminaire driver shall be of the same make/manufacturer as that of LED luminaires. Luminaire manufacturer must have in house NABL accredited lab conduct LM79, type test as per IS10322 & "FAT" before dispatch as per IS 10322. The contractor must submit the NABL accreditation certificate for luminaire manufacturer along with sample approval. The LED Luminaire & It's driver both should be BIS registered. Contractor shall submit the following reports before supply of material for approvals LM79 issued by NABL accredited lab, LM80 issued by LED manufacturer type test certificate for luminaire as issued by NABL accredited lab, RoHS compliance issued by LED luminaire manufacturer, BIS certificate for LED Luminaire & Driver complete all as specified and as directed.
S&F in repair lamp holder, PVC/polycarbonate type with back plate straight or angular suitable for batten fittings complete all as specified and as directed.
S&F LED Bulb of 9 watt Oval diffuser to give glare free light, IP50 of lumen output should be greater than 1100 lumen, CCT 4000-5700, CRI>=70, THD must be less than 10%, Power factor more than 0.9, working voltage 140-270V, life time should not be less than 25KHr complete all as specified and as directed.
Supply Installation, testing & comissioning in repair Integral / batten LED 2ft, 10 watt 220 V, luminaire made of CRCA/extruded aluminium housing and PC diffuser (Diffuser-Non yellowing type). The luminaire should have a LEDs with colour consistency SDCM ≤ 5, CRI ≥ 80 and CCT of 6500K. Luminaire shall be designed to emit at least minimum 2000 system lumens at a system efficacy of at-least 120 lumen/watt. Power consumption should not be more than 10W (± 5%). The Life of fixture (Including Driver):50000 burning Hrs. @ L70B50 Lumen maintenance @ design ambient temp 45 deg C. The electronic driver used shall have a power factor 0.95 and THD ≤10%, suitable for an operating voltage range of 140-270V AC, Current Ripple ≤ 5%, Internal surge protection should be minimum 4KV, electrical insulation class should be Class I & driver should be of Class B serviceability. The luminaire shall be IP20 & IK02 compliant.The luminaire driver shall be of the same make/manufacturer as that of LED luminaires. Luminaire manufacturer must have In-house NABL accredited lab to conduct LM79, Type test as per IS10322 & "FAT" before dispatch as per IS 10322. The contractor must submit the NABL accreditation certificate for Luminaire manufacturer along with sample approval. The LED Luminaire & it's driver both should be BIS registered. Contractor shall submit the following reports before supply of sample approvals LM79 issued by NABL accrediated lab, LM80 issued by LED manufacturer, Type Test Certificate for luminaire as issued by NABL accrediate lab, RoHS compliance issued by LED luminaire manufacturer, BIS certificate for LED Luminaire & Driver complete all as specified and as directed.
S&F LED type wall mounted light fitting suitable for LED lamp 20w, housing glass, frosted type, metalic frame complete all as specified and as directed. Make : Philips Cat No 31453, 20watt wall light or equivalent make specified in make list.
S&F in repair Hot water storage (Geyser) 25 Ltrs capacity,BEE 5 star rated,vertical type,digital temperature display with suitable size of fastner and including provision and connecting up of SS braided pipe with adopter for inlet and outlet water connection, copper element corrosion resistance antiscaling magnesium anode, having adjustable knob for temperature control and inner tank material of superior glassline coating / percelain Enamel Coating / Titanium Enamel Coating / Nano Blue Diamond Glass Coating / Coating with Single Weld line tank and outer body material ABS with high pressure with standing capacity upto 8 bar pressure, Multiple safety systems for protection against dry heating, overheating and over pressure,IPX4 waterproof technology for longer product life having heating element 2 KW and minimum two year warranty on product, minimum 3 years warranty on heating element and 5 years on tank complete all as specified and as directed.
M&L for cutting of circular hole in any type of wall suitable size for fixing exhaust fan of size 300 mm sweep, grouting 04 Nos 100 mm long 12 mm dia stud bolt including, making good the disturbed surface of wall to match the existing complete all as specified and as directed.
M&L for cutting of square hole in any type of wall suitable size for fixing exhaust fan of size 250 mm sweep, grouting 04 Nos 100 mm long 12 mm dia stud bolt including, making good the disturbed surface of wall to match the existing complete all as specified and as directed.
S&F exhaust fan AC single phase 230/240 Volt of size 250 mm sweep fiber body with louvers complete all as specified and as directed.
S&F Exhaust fan 300 mm sweep, copper winding,metal body, four metal blades BEE approved/ISI marked, air delivery shall not be less than 1600 CMH at 1400 RPM, mounted in suitable opening arrangement with louvers shutters, suitable for operation on 240 volt, single phase, 50 cycle per second, AC supply and connecting up using flexible cord wire 3 core using PVC flexible conduit from ceiling rose or connector to fan to cover PVC cable fixed in position as recommended by manufacturer complete all as specified and as directed.
S&F 32 mm dia GI tubing light grade bracket all over 1.2 mtr length with cutting as required and bend to shape with flat iron clamp of size 32 mm x 5 mm , 2 Nos with suitable size of nuts, bolts and washers including two coats of synthetic enamel paint over a coat of red oxide primer on the suface of MS clamp for street / Bldg security light fittings after taking down old existing unserviceable brackets and light fitting complete all as specified and as directed.
S&F LED street light fitting 35 Watt, including LED lamp complete with body robust, corrosion resistant, superior finish and without any cracks or through holes, made in a single piece, high pressure die cast aluminium alloy, monolithic construction totally enclosed, dust and water proof with minimum IP65 protection as per IS-10322-1982(Part-I) with latest amendments and input voltage range 140-300 VAC, frequency 50-60Hz, P.F should be more than 0.9 with THD(I) less than 10%, cool white color and. Fitting should be provided with min 4 KV surge protection, constant current constant voltage driver, high voltage withstanding capacity upto 300 VAC and also have double phase protection, no load, open circuit and short circuit protection, Light fitting suitable for ambient temperature from minus 10 degree Centigrade to 50 degree Centigrade and humidity level 10% to 90% RH. Covers should be polycarbonate/toughened glass to ensure minimum IP65 degree protection. The lumen output shall not be less than be 110 lumens per watt, life should not less than 40Khr, color index 6000K and must be certified by the relevant test report Fitting should fixed on pole using and including 1.2 m long 40 mm dia GI pipe light grade bend to shape and fixed using two Nos clamps fabricated by MS Flat iron 40x5mm including necessary nut bolts and washers and two coats of synthetic enamel paint over a coat of red oxide primer on the surface of clamp and making electrical connection using 1.5 Sqmm, 3 core multi-stranded copper conductor PVC insulated and over all PVC sheathed cable form light fitting to junction box complete all as specified and directed .
S&F in repair MCB DB 4 way TPN, sheet metal enclosure suitable for fixing MCB of appropriate capacity as incomer and SP for outgoing ,415 volts, 50 Hz, with IP-43 protection, double door with 100 Amps standard bus bar of suitable size and common neutral link all enclosed in standard sheet flush mounting including complete all as specified and directed. Note : (i) MCBs shall be measured and paid separately under appropriate items. (ii) Copper thimble shall be used for connection of cable and the cost of the same shall be included in the quoted rate of this item .
S&F in repair MCB Distribution board, 240 volts single pole and neutral,double door, sheet steel, enclosure powder coated with 100 Amps rated busbar with neutral link, 12 ways, fixed on wall duly grouted in solid block wall or on wooden board with electrical connection complete all as specified and directed.
S&F MCB 4 pole, 40 Amps, 16KA breaking capacity 415 Volts complete all as specified and directed
S&F RCBO with earth leakage, over load and short circuit proptection, DP, 240 Volts, 32 Amps, 30 mA senstivity, 4 Module complete all as specified and directed.
S&F MCB, single pole 240 volts 6 to 32 Amps capacity fixed complete all as specified and as directed.
M&L for submain wiring with PVC insulated unsheathed copper conductor multi stranded FRLS type 1100V, grade 2 x 6 Sqmm drawn in and including new PVC concealed conduit of suitable size and its accessories along with 1x 6 sqmm PVC insulated unsheathed copper conductor multi stranded FRLS type cable for continuous earth wire and duly connected to common earth dolly including taking down old existing unserviceable sub main wiring complete all as specified and directed Note :- (i) Three runs of 6 Sqmm cable and one run of PVC conduit shall be measured as one unit length. (ii) The cost of cutting chases for concealed conduit wiring and making good in cement mortar is deemed to be included in unit quoted rate for these item.
Taking down existing energy meter and refixing the same on the original location after completion of all work complete all as directed.
M&L for earthing complete with galvanised steel earth plate electrode 60cmx60cmx6mm buried directly in ground vertically to depth not less than 2.25m below normal ground level with top edge of the earth plate at a depth not less than 1.5m below ground level connected to and including GI wire of dia 4mm by means of nuts, bolts, check nuts and washer etc, made of GI and connected to test point and earth dully all as shown in electrical plate No. 3 SSR Part-I 2009 and specified or indicated including excavation and earthwork in Any type of Soil PCC (1:3:6) Type C1 in chamber, precast RCC 50 mm thick in cement concrete (1:2:4) type B1, reinforced with welded steel wire fabric or XPM (Weight not less than 4.00 Kg/Square metre) with PCC frame, funnel with wire mesh, 20mm bore medium grade GI watering pipe, lugs, 15mm bore medium grade GI protection pipe, test point after demolishing the existing one complete all as specified and directed.
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for laying of cable/erection of pole and getting out in soft/loose all complete as specified and directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc. 25 cm in soft / loose soil complete all as specified and as directed.
Removal of excavated soil to a distance not exc 50 m and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as directed.
Supply and fixing/laying 40 mm bore, steel tubings, galvanised, light grade with all fitting laid across road , in trenches or across PCC drain or along electric pole or floor/wall etc for protection of cable complete all as specified and as directed.
M&L sand cushioning using clean Fine River sand for underground cable 8 cm before laying cable and 15 cm after laying and punned to 18 cm after laying of cable complete all as specified and directed. ( Note:- Punned thickness shall be considered for payment purpose)
Supply and laying Best quality, locally available, sub class ‘B’ clay bricks (Old Size) for cable protection cover, laid flat and dry in trenches over the cable , perpendicular to the direction of cable complete all as specified and directed.
Taking out old unservicable under ground LT XLPE / PVC cable of any size from trenches / wall / roof / road / pipe / pole / DB including taking out of brick layer of cable protection complete all as directed.
Supply and laying or fixing or laid in trenches / ducts / through pipes / in floors / under roads / hard standing /along poles and testing XLPE, LT Cable, with PVC outer sheath Type-I as per IS - 5831, insulated stranded aluminium conductor as Per Class-2 of IS - 8130 served with and inner sheathining of PVC tape- ST-I as per IS-5831 color Red, Yellow, Blue & Black ,armoured with Galvanised steel strip and over all PVC sheathed stranded conductor conforming to IS-1554 (Part-I & II) with latest amendments of Size cross sectional area 25 Sqmm 4 core ,1100 volts grade heavy duty complete all as specified and as directed.
Supply, Installation, testing and commissioning of 1200 mm sweep BEE 5 star rated, Ceiling fan with Brush Less Direct Current (BLDC) Motor, Class of insulation : B, power factor not less than 0.9, service value (CMM/W) minimum 6.85, Air delivery not less than 230 CMM,350 RPM (tolerance as per IS:374-2019), THD less than 10%,including remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nuts bolts, washers, temperature rise =75 degree C (maximum), insulation resistance more than 2 mega Ohm, suitable for 230V, 50 Hz, single phase AC supply complete including taking down old ceiling fan and deposited the same to MES store yard complete all as specified and as directed.
S&F surge protection device (SPD) single phase, 230V, 50Hz, T-2 limb, Imax 20KA per pole fixed in distribution board and making connection complete all as specified and as directed. Note : For Srl No 1 to 167 Rate Quoted against each item is inclusive of cost of scaffolding if required at site.
MAHINDER ELECTRICALS (BID ID -3087170)
N.V.ENGINEERING (BID ID -3094177)
M/s JK Jangid and Company (BID ID -3094123)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .