Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.4 CrAccepted-AOC NO 15 B 2ND FLOOR 4TH CROSS T ASHWATHNARAYANA ROAD THIMMAIAH NAGARA YELAHANKA BANGALORE 560 064 | BANGALORE | BANGALORE | KARNATAKA | 560064 | ₹2.4 Cr | L1 | Accepted-AOC L1 |
| 2 | L2₹2.7 Cr+₹34.4 L (14.4%)Rejected-Finance | ₹2.7 Cr+₹34.4 L (14.4%) | L2 | Rejected-Finance Other than L1 |
| 3 | L3₹2.8 Cr+₹38.0 L (15.9%)Rejected-Finance | ₹2.8 Cr+₹38.0 L (15.9%) | L3 | Rejected-Finance Other than L1 |
| 4 | L4₹3.2 Cr+₹78.4 L (32.8%)Rejected-Finance | ₹3.2 Cr+₹78.4 L (32.8%) | L4 | Rejected-Finance Other than L1 |
| 5 | L5₹3.5 Cr+₹1.1 Cr (46.4%)Rejected-Finance | ₹3.5 Cr+₹1.1 Cr (46.4%) | L5 | Rejected-Finance Other than L1 |
Tender Value
₹3.5 Cr
EMD Value
₹4.2 L
Closing Date
9 Dec 2019, 6:00 pmClosed
CE R AND D SECUNDERABAD
CE R AND D SECUNDERABAD
CONSTRUCTION OF ADDITIONAL FLOOR AT SCENARIO SIMULATION CENTRE FOR TECHNICAL DISPLAY FACILITY AT LRDE BENGALURU
2019_MES_272277_1
CERD/BAN/TOKEN/02 OF 2019-2020
Open Tender
Civil Works
Lump-sum
365 days
GE I R AND D WEST BENGALURU
CLASS A
CATEGORY a i
and REFER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹2,000
GE I R AND D WEST BENGALURU
₹4.2 L
Yes
5 Feb 2020
2 Aug 2019
12 Dec 2019
2 Aug 2019
9 Dec 2019
22 Nov 2019
3 Aug 2019 - 9 Aug 2019
Amount
Schedule 'A' Part - I (BUILDINGS AND STRUCTURES) This Schedule (contains under mentioned Sl. item No. 1.01) is not prepriced by MES and the prepriced rate indicated in Col - 5 as `0.00 indicates this fact only.The tenderer is required to quote their rates in Column 6.
Lumpsum price worked out by the contractor for Construction of additional floor on existing ground floor building at Scenario simulation centre, including provision of staircase No. 2 at left side from ground floor to first floor and provision of extension of existing staircase No. 1 upto mumty level (over first floor roof slab) including provision of mumty, complete all as shown on drawings and as specified.
Lump sum price worked out by the Contractor for "DISMANTLING / DEMOLITION” as listed in Schedule ‘A’ Part - II representing _______ % ________________ percent Above / Below the lumpsum price of `37,905.63 inserted by the MES in Schedule ‘A’ Part - II
Lump sum price worked out by the Contractor for “EXCAVATION, EARTHWORK AND SITE CLEARANCE” as listed in Schedule ‘A’ Part - III representing _______ % ______________ percent Above / Below the lump sum price of `14,002.80 inserted by the MES in Schedule ‘A’ Part - III
Lump sum price worked out by the Contractor for “EXTERNAL ELECTRIFICATION” as listed in Schedule ‘A’ Part - IV representing __________ % ____________ percent Above / Below the lump sum price of `1,91,150.67 inserted by the MES in Schedule ‘A’ Part - IV
Lump sum price worked out by the Contractor for "EXTERNAL WATER SUPPLY” as listed in Schedule ‘A’ Part - V representing _______ % __________________ percent Above / Below the lump sum price of `33,955.70 inserted by the MES in Schedule ‘A’ Part - V
Lump sum price worked out by the Contractor for “INTERNAL WATER SUPPLY” as listed in Schedule ‘A’ Part - VI representing _______ % _________________ percent Above / Below the lump sum price of `7,914.20 inserted by the MES in Schedule ‘A’ Part - VI
Lump sum price worked out by the Contractor for “INTERNAL ELECTRIFICATION” as listed in Schedule ‘A’ Part - VII representing _______ % _________________ percent Above / Below the lump sum price of `77,035.90 inserted by the MES in Schedule ‘A’ Part - VII
Schedule 'A' Part - VIII This Schedule is not prepriced by MES and the prepriced rate indicated in Col - 5 as `0.00 indicates this fact only.The tenderer is required to quote their rates in Column 6. This Schedule constitutes Sl. Item No. 8.01 to 8.62
Sl. Item No. 8.01 to 8.10 here-in-after shall constitute for "EXTERNAL ELECTRIFICATION" Supply and install, testing and commissioning of distribution Transformer, of 160 KVA capacity, step down, outdoor, floor mounted type, double copper wound, core type, 3 phase,50 Hz, AC, Oil immersed with "ONAN" type coolong with external cooling tubes / radiators having no load voltage ratio 11 / 0.433 KV ( Corresponding to principal tapping) delta connected on primary side (HV incoming) and star connected on secondary side (secondary out goint) in accordance with vector group symbol (Dyn-II conforming to IS 1180-2014) with bushings on primary side & cable terminal box on secondary side and having off load tap changer in the steps of 2.5% on HV side to take care of voltage from (+) 7.5 %, (+) 5%, (+) 2.5%, (0), (-)2.5%, (-)5%, (-) 7.5% to give out put on 433 V secondary side and with standard fittings such as dial type temperature gauge for reading maximum temperature, conservator, oil level indicator, drain out valve, silica gel breather, explosion vent diaphragm all as per IS:2026, including initial filling of transformer oil, having dielectric strength not less than 50 KV (rms) with gap of 2.5 mm, conforming to IS:335-1993, complete all as specified and directed. MAKE:- ABB / AREVA / GE ALSTHOM / VOLTAMP / ESENNAR / CROMPTON GREAVES / ITE GURGAON
SL. ITEM NO. 8.02 CONTD... INCOMING: (a) MCCB 4 pole 250 Amps, 50 Hz, 415V, 36KA rupturing capacity, adjustable over load 70-100% with thermal magnetic release Ics = 100% Icu - 01 No (b) On load change over switch 250Amp, FP - 01 No (c) Digital type multi-functional A, V, Z, kW, PF meter - 01 No (d) LED indicator set of 3 - 01 No OUTGOING: (a) MCCB 4 pole 100 Amps, 50 Hz, 415V, 16KA rupturing capacity, adjustable over load 70-100% with thermal magnetic release Ics = 100% Icu - 02 Nos (b) MCCB 4 pole 63 Amps, 50 Hz, 415V, 16KA rupturing capacity, adjustable over load 70-100% with thermal magnetic release Ics = 100% Icu - 01 No (c) Digital type multi-functional ammeter - 03 Nos (d) LED indicator set of 3 - 03 Nos MAKE (for LT Panel & Switchgears):- ABB / SIEMENS / SCHNEIDER
Earthing complete with GI earth plate electrode 600mm x 600mm x 6.3mm thick buried directly in ground vertically to a depth of not less than 2.25m deep below ground level with the top edge of earth plate at a depth of not less than 1.5m below ground level connected to GI earth strip 32mm x 6mm by means of bolts, nuts, washers of galvanised iron or steel, GI earth wire shall be protected by 40mm dia GI pipe 'medium grade', watering pipe 20mm dia GI pipe 'light grade', GI wire meshed funnel, alternate layer of charcoal and salt on all side to earth plate upto a thickness of 150mm, filling of black cotton soil in earth pit upto GL and connected to earth plate including necessary excavation & earthwork, PCC (1:3:6) type C-1 earth chamber, 40mm thick RCC cover (1:2:4) mix with 6mm dia nominal reinforcement @ 150mm c/c both ways etc complete all as shown in electrical plate No.3 connected to earthing test point, including testing on completion, complete all as speciifed and as directed. NOTE:- Earthing strip and GI protection pipe light grade both beyond 7.50metre shall be measured and paid separately under respective items of this Schedule.
HT 11KV under ground XLPE insulated, armoured heavy duty, screened, PVC bedded, galvanised steel strip / wire armoured, electric cable with aluminium conductor, 11000 volts grade, earthed, ISI marked as per IS-7098 (Part 2) - 1985, cross-sectional area 95 sq.mm 3-core, laid in trenches / on poles / walls including provision of suitable hardware accessories, connecting up, testing on completion and commissioning, complete all as specified and directed.
XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, heavy duty electric cable with stranded aluminium conductor, LT 1100 volts grade, ISI mark as per IS-7098 (Part -1) -1985, cross-sectional area 240 sq.mm 3.5core, laid in trenches / on poles / walls including provision of suitable hardware accessories, connecting up, testing on completion and commissioning, complete all as specified and directed.
XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, heavy duty electric cable with stranded aluminium conductor, LT 1100 volts grade, ISI mark as per IS-7098 (Part -1) -1985, cross-sectional area 120 sq.mm 3.5core, laid in trenches / on poles / walls including provision of suitable hardware accessories, connecting up, testing on completion and commissioning, complete all as specified and directed.
Designm, fabricate, supply, install, testing and commissioining of indoor type Automatic Power Factor Correction (APFC) Panel, 100 KVAR capacity, with double door shutters; Panel made out of 2mm thick MS sheet, weather proof, to accommodate MCBs & capacitors etc., as mentioned below, with and including necessary provision / space for future expasion / additions of capacitor 20KVAR - 01 No., including contactors, consisting with and including provision of the following, complete all as specified and directed. MAKE:- Cat No. QHKTCB5100X0 of Havells or techno-commercially equivalent model in Schneider / L&T (a) MCCB FP 415Volt, 200Amp, 50Hz with thermal magnetic release and Ics = 100%Icu with rupturing capacity 35KA, adjustable overload minimum 70-100% - 01 No (b) Capacitors 100KVAR, microprocessor based 440Volt, 50-60Hz, designed for medium to large load networks / unbalanced load apart from balanced load, connected on 3 bphase 415Volt rated all as directed. Capacitor bank shall be suitable for 8 stage (1 x 5KVAR, 2 x 10KVAR, 1 x 15KVAR, 3 x 20KVAR) and there shall be provision for 8th stage for future expansion including heavy duty contactor and wiring suitable for 20KVAR capacitor - 01 No, including neceesary copper cable connection termination of suitable capacity from any bus bar to MCB, to contactor and capacitor.
SL.NO. 8.08 CONTD... (f) Axial flow / centrifulgal fan-controlled through thermostat (g) High electrolytic grade aluminium busbar of capacity 300Amp TPN (h) Structure finish : RAL 7035 powder coated (i) The controlling of capacitors shall be through MCBs (suitable for capacitve load) NOTE:- The quoted rate shall deemed to be included the cost of twin core armoured underground cable with copper conductor of suitable size from LT panel / transformer to APFC panel for sensing as required, etc., complete for satisfactory completion of work, complete all as specifeid and directed.
"EXTERNAL WATER SUPPLY" Cutting of existing GI Pipe line 50 mm dia in site and inserting new tee 50mm x 50mm x 25mm dia complete with threading for making new branch connection of 50mm dia including necessary fittings, complete all as specified and directed.
Sl. Item No. 8.12 to 8.17 here-in-after shall constitute for "DG SUPPLY" Supply, install, connect, test and commission of Diesel Engine driven Generator Set of capacity 160 KVA / 128 KW with diesel engine directly coupled through holset type coupling or close coupling in order to form a very compact arrangements and both units will be mounted on a rigid fabricated base plate along with standard automated AMF control panel, shall comprise of the following items (with and incluidng provision of) :- (A) ENGINE Diesel Oil Engine (243 BHP) direct injection, 4 stroke vertical in line cylinders, liquid cooled with specified shaft output after reduction of power for engine Auxiliaries and when operating at a governed speed of 1500 RPM at NTP condition. The engine is suitable for continuous duty and conforms to IS 10000 (except for HA 694 and turbo charged engines which confirm to BS 5514). The engine must be complete with all standard accessories and fittings as detailed below:- 1. Flywheel and flywheel housing 2. 24 V DC electric start arrangement 3. Exhaust Silencer – Residential Type Silencer 4. Fuel Filter (Pre and Micro) 5. Lube oil filter “Spin-on” type 6.Radiator (For liquid cooled DG set only)
SL. ITEM NO. 8.12 CONTD... 7.Dry Type Air Cleaner 8.Battery charging Alternator 9.Fuel hoses 10.Maintenance manual and spare parts catalogue 11.Radiator fan (For liquid cooled DG set only) 12.Fuel injection pump with mechanical / electronic (128 KW & 160 KVA) governor and fuel feed pump 13. Engine safety protection for High Liquid Temperature and Low Lube Oil Pressure 14. Governor Electronic type(Microprocessor controlled) 15. Closed Coupled Engine with inbuilt Anti Vibration Mounting Pads 16. First Fill of Lube Oil 17. First Fill of Coolant (Life is 3000 running hours or 2 years) 18. Genset Controller consists of Engine parameters like R.P.M., Liquid Temperature, Oil Pressure, Fuel level indication, Engine Hours run & Alternator parameters like Voltage, Frequency, Amps, KW, KVAR, PF etc. 19. Genset Controller also have protection for High Liquid Temperature, Low Lube Oil Pressure, Under speed & Over speed MAKES OF DIESEL ENGINE :- KIRLOSKAR GREEN / CUMMINS / GREAVES COTTON
SL. ITEM NO. 8.12 CONTD... (B) ALTERNATOR Self – excited, self – regulated, screen protected, drip proof alternator with static excitation system, capable of developing rated output at 415V, 0.8 p.f. 50 Hz when running at 1500 RPM at NTP conditions and conforms to the IS 4722 standards. MAKES OF ALTERNATOR :- KIRLOSKAR GREEN / STAMFORD / GREAVES COTTON (C) AUTO MAIN FAILURE (AMF) PANEL AMF panel made out of 2mm CRCA sheet, powder coated, conforming to IS 8623 totally enclosed dust and vermin proof with front and rear openings of 415Volts, 3 phase, 4 wire, AC 50Hz having amuminium busbar capacity required to carry current at 110% load of 160KVA DG set with three phase and neutral colour coded, pre-wired with copper flexible cable, complete all as specified and directed, with and including provision of the following accessories and provision of control cable from Gen set to AMF panel :- (a) MCCB FP 250Amp, Icu = 36KA, Ics = 100%Icu with microprocessor release and adjustable overload setting (minimum 70% to 100%) and fixed magnetic setting - 02 Nos (for both switches)
SL. ITEM NO. 8.12 CONTD... (b) CTs 200/5A for both the supplies (c) Push buttons (d) Indication lamps (e) 2 over load + earth leakage relay (f) multifunctional digital meter for KWH, KVA, KW, Amp, Volt, frequency, power factoretc., (g) SMPS battery charger 12V, with trickle & boost charging (h) On / Off switch (i) Automatic / manual switch (j) Hooter (k) Voltage sensing relay (l) Six window annunciator for fault indications (m) Electro magnetic relays (n) Four pole power contactor conforming to IS / IEC 60947-4-1 with AC1 rating 325Amp with auxiliary contacts 2NO + 2NC with standard coil voltage 415Volt, 50 Hz - 02 Nos MAKE;- (for contactors) : L&T type MCX41 Cat No. CS97023 or techno-commercially equivalent model in BCH / ABB / SIEMENS (D) ACOUSTIC ENCLOSURE NOISE LEVEL :-75 DB at 1 metre from the enclosure surface under free field conditions as per CPCB Norms. CONSTRUCTION :- Acoustic Enclosure shall be powder coated and fabricated out of 16 SWG CRCA MS sheet. The silent canopy shall be of nut bolt type
SL. ITEM NO. 8.12 CONTD... construction. Powder coating is done after seven-tank surface preparation process of sheet metal. Canopy panel and doors shall have inside lining of FIRE-RETARDANT foam as acoustic material. Four hinged doors shall be provided to canopy, one door shall have glass window for control panel. (E) BASE FRAME:- Base frame is fabricated in sheet metal. The base frame is rugged in construction and designed for mounting engineand alternator close coupled, with cross members mounted on AVM. The base frame shall have provision for mounting of acoustic enclosure. The base frame is having provision of lifting hook for convenient lifting of complete set, i.e., along with canopy, engine and alternator. (F) FUEL TANK :- Removable fuel tank with 8 hours full load running capacity fabricated out of CRCA MS sheet and is part of base frame. It is duly painted and fitted with inlet and outlet connections. Fuel tank can be easily removed for cleaning or any maintenance. (G) ACCESSORIES:- 1) 2 Nos. Dry 120AH 12V Battery 2). 1 set Battery leads 3)1 No. Exhaust Expansion Bellow
Earthing complete with GI earth plate electrode 600mm x 600mm x 6.3mm thick buried directly in ground vertically to a depth of not less than 2.25m deep below ground level with the top edge of earth plate at a depth of not less than 1.5m below ground level connected to GI earth strip 25mm x 4mm by means of bolts, nuts, washers of galvanised iron or steel, GI earth wire shall be protected by 40mm dia GI pipe 'medium grade', watering pipe 20mm dia GI pipe 'light grade', GI wire meshed funnel, alternate layer of charcoal and salt on all side to earth plate upto a thickness of 150mm, filling of black cotton soil in earth pit upto GL and connected to earth plate including necessary excavation & earthwork, PCC (1:3:6) type C-1 earth chamber, 40mm thick RCC cover (1:2:4) mix with 6mm dia nominal reinforcement @ 150mm c/c both ways etc complete all as shown in electrical plate No.3 connected to earthing test point, including testing on completion, complete all as speciifed and as directed.
Sl. Item No. 8.18 to 8.20 here-in-after shall constitute for "AIRCONDITIONING" Supply and install Cassette type units, 4.0 TR capacity, with indoor / outdoor unit run on R410A refrigerant, complete with cordless remote control unit, rotary compressor, three phase 415V, 50 Hz, complete all as specified and directed. MAKE:- DAIKIN / VOLTAS / BLUESTAR
Copper tube for refrigerant of size 15.875mm (5/8 inches) - 9.525mm (3/8 inches) with PU insulation run on walls / ceiling duly fixed with clamps including making necessary hole for drawing out the pipes and connecting, complete all as specified and directed.
Sub main wiring complete with 4 runs of 6 sq.mm PVC insulated and unsheathed 1100V grade multistranded FRLS grade copper conductor cable drawn through and including provision of concealed non-metallic rigid PVC conduit 25mm dia and its accessories and connecting terminal ends to DB's including providing 2 runs of 6sq.mm PVC insulated unsheathed multistranded FR grade copper cable as earth continuity conductor and connecting to common earth dolly, complete all as specified and directed. NOTE:- (i) Four runs of 6 sq.mm copper conductor, two runs of 6 sq.mm copper earth continuity conductor and one run of PVC conduit shall be measured as one unit length. (ii) Extra length of cable / wire required for connection to MCBs shall not be measured and the rate quoted per unit shall deemed to be inclusive of the same accordingly.
Sl. Item No. 8.21 to 8.29 here-in-after shall constitute for "FIRE ALARM SYSTEM" Supply and installation of intelligent addressable 1 loop fire alarm control panel and shall be able to connect 254 devices (detector or module) per loop and approved EN54, complete all as specified and directed.
Supply and installation of intelligent addressable smoke detector sensor with base, complete all as specified and directed.
Supply and installation of intelligent addressable manual call point in breakglass unit, complete all as specified and directed.
Supply and installation of intelligent addressable notification appliances sounder with strobe, complete all as specified and directed.
Supply and installation of addressable fault isolator, complete all as specified and directed.
Supply and installation of response indicator, complete all as specified and directed.
Supply and installation of monitor module intelligent addressable supervised class B monitoring module, monitoring of normally open dry contacts, complete all as specified and directed.
Supply and installation of relay module intelligent addressable signle adressable control relay module form 'C' contact type for AHU tripping, ACS, FA / PA integration, sliding door etc., complete all as specified and directed. MAKE;- (for Sl. No. 8.21 to 8.28 here-in-before which constitute fire alarm system) SIEMENS / SIMPLEX / EDWADS / HONEYWELL / NOTIFIER
PVC sheathed round copper conductor flexible cable 3 core 1.5sq.mm, passing through and including provision of 20mm dia heavy duty rigid PVC conduit, complete all as specified and directed.
Sl. Item No. 8.30 to 8.34 here-in-after shall constitute for "WALL PANELLING & FALSE CEILING" Solid PVC wall lining consisting of 5mm thick, plain colour PVC sheet, inclusive of solvent cement and fixing at site on PVC frame, complete all as specified and directed.
5mm thick PVC sheet fillet of width 35mm for wall paneling inclusive of fixing on to wall to make PVC Frame, complete all as specified and directed.
Gl frame work for seamless ceiling comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre / intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approximately 900 mm centre-to-centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exceeding 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre-to-centre, in ceiling fixed with screw suspended with hangers of 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 mm x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long (for Gypsum board periphery section made of GI angle fixed with dash fastner at 450mm centre-to-centre), complete all as specified and directed.
Exposed metal frame ceiling, any type and any colour, with 12mm thick calcium silicate board of siliceous and calcareous material reinforced with cellulose fibre for fixing in 600 mm x 600mm grid (Frame work for ceiling shall be measured and paid separately under respective items of this Schedule), complete all as specified and directed.
Providing and fixing Gypsum Board 12mm thick, any colour, in ceiling fixed with screws 4.5mm from under side @230mm centre-to-centre by drilling machine, joint of board shall be finished flush with filters, finish to give a seamless finish, with and including preparation of ceiling surfaces and applying two coat of plastic emulsion paint over a coat of primer, complete all as per manufacturers instructions, including cutting slots for lighting, complete all as specified and directed.
Sl. Item No. 8.35 to 8.40 here-in-after shall constitute for "EXTERNAL WALL CLADDING AND WALL FINISHES TO EXISTING FLOOR PORTION" Heat absorbing / tinted reflective glass, 6mm thick, providede in panel size exceeding 0.50sq.m each with and including provision of rubber beading of silicon material, complete all as specified and directed.
Fixing only 6mm thick heat absorbing glass in panels of size exceeding 0.50sq.m each with and including provision of rubber beading of silicon material, complete all as specified and directed.
Rolled mild steel sections conforming to Fe-410-W (Grade E-250) quality - B, as in framing for cladding, glazing and the like fixed with angle cleats and connecting plates, etc., complete all as specified and directed.
Powder coated aluminium (thickness of powder coating shall not be less than 50microns) frame for doors, windows, ventilators, partitions, glazing, cladding etc., with one or more rebates including joining cleat for fixing etc, complete all as specified and directed.
Complete removal of existing treatment from surfaces of walls, ceilings incuding pilasters, cornices etc., by scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots with wire brushes and removing existing loose particles etc., and applying two coats of weather-proof antifungal exterior emulsion paint over a self coat of primer, over two coats of external grade wall care putty (viz., 1.5mm thick in first coat and 1.0mm thick in second coat; however, the total thickness shall not be less than 2.50mm), finished even and smooth, complete all as specified and directed.
Taking out old serviceable glass of any description, from old wooden or metal frames, or stone, concrete or brick surrounds, any thickness or size; hacking out old putty or removing beads etc,, including making good breakages in taking out and handling removing to store or stacking for reuse, complete all as specified and directed.
Sl. Item No. 8.41 to 8.62 here-in-after shall constitute for "INTERNAL ELECTRIFICATION" Point wiring complete with 1.5 sq.mm PVC insulated unsheathed multi-stranded FRLS copper conductor 1100 Volts grade, ISI marked, drawn through and including provision of 20mm dia rigid PVC conduit medium grade ISI marked and conduit accessories, concealed in stone / brick masonry walls, roofs, floors etc, by means of saddles and clips etc, including provision of modular metal flush boxes (metal switch board of any type and size with GI metal box) with modular metal frame plate and white cover for housing switches, sockets, regulators etc., including 1.5sq.mm PVC insulated unsheathed multi-stranded FRLS copper conductor cable as earth continuity conductor and connecting to common earth dolly, complete all as specified and directed for one light / fan point controlled by one 6 amps one way modular switch, complete all as specified and directed. NOTE: (i) The quoted rate shall deemed to include the cost of metal flush boxes, modular white cover plate, provision of blank plates as per requirement etc. (ii) Quoted rate shall deemed to be include cost of making necessary chases in walls / ceilings / floors for inserting metal boxes and making good the disturbed surfaces to match with existing
All as per Sl. Item No. 8.41 here-in-before but for air circulator / fan point controlled one number one-way switch
All as per Sl. Item No. 8.41 here-in-before but for one 3-pin 6 Amps socket outlet point controlled by one one-way switch on independent board
All as per Sl. Item No. 8.41 here-in-before but for one 3-pin 6 Amps socket outlet point controlled by one one-way switch on same board
Point wiring complete with 2.5 sq.mm PVC insulated unsheathed multi-stranded FRLS copper conductor 1100 Volts grade, ISI marked, drawn through and including provision of 20mm dia rigid PVC conduit medium grade ISI marked and conduit accessories, concealed in stone / brick masonry walls, roofs, floors etc, by means of saddles and clips etc, including provision of modular metal flush boxes (metal switch board of any type and size with GI metal box) with modular metal frame plate and white cover for housing switches, sockets, regulators etc., including 2.5sq.mm PVC insulated unsheathed multi-stranded FRLS copper conductor cable as earth continuity conductor and connecting to common earth dolly, complete all as specified and directed for 3/6 pin 15Amp socket outlet on indiependent board, complete all as specified and directed. NOTE: (i) The quoted rate shall deemed to include the cost of metal flush boxes, modular white cover plate, provision of blank plates as per requirement etc. (ii) Quoted rate shall deemed to be include cost of making necessary chases in walls for inserting metal boxes and making good the disturbed surfaces to match with existing
LED, 20Watt, high efficient, batten surface / wall mounted with specially designed extruded aluminium housing, high optically efficient poly-carbonate diffuser, in-built electronic driver duly wired upto terminal block, power consumption less than or equal to 20W, luminaire lumen greater than or equal to 2000lm, system efficiency greater than or equal to 100lm/w, led MAKE : Nichia / Cree / Everlite / Eclison / Osram / Lumiled with LED binning as per ANSI Bin C78.377A, photo biological safety report as per IEC62471 & electrical insulation class 1, ingress protection IP 20, colour rendering index CRI > 80%, temperature range 0-50 degree centigrade, driver efficieny > 85% power factor > 0.90, THD < 20% as per IEC 61000-3-2, colour temp - 6500K, surge protection 2.5KV, 50000 burning hours (minium) as per L70 criteria, multi-stage isolated constant current operated driver with range 110-270V AC and safety extra low voltage safe level < 60V DC as per IEC Standard with LM70 & LM80 certification, complete all as specified and directed. MAKE:- Cat No. LL20-281-XXX-65AL1 of Wipro / Cat No. ENDURALINEARNEOBS20WLED865SPCWH of Havells or techno-commercially equivlent model in Philips / Bajaj
LED, 10Watt, high efficient, batten surface / wall mounted with specially designed extruded aluminium housing, high optically efficient poly-carbonate diffuser, in-built electronic driver duly pre-wired upto terminal block, power consumption less than or equal to 10W, luminaire lumen greater than or equal to 1000lm, system efficiency greater than or equal to 100lm/w, LED Make :- Nichia / Cree / Osram / Everlite / Eclison / Lumiled, with LED binning as per ANSI Bin C78.377A, photo biological safety report as per IEC62471 & electrical insulation class 1, ingress protection IP 20, colour rendering index CRI > 80%, temperature range 0-50 degree centigrade, driver efficieny > 85% power factor > 0.90, THD < 20% as per IEC 61000-3-2, colour temp - 6500K, surge protection 2.5KV, 50000 burning hours (minium) as per L70 criteria, multi-stage isolated constant current operated driver with range 110-270V AC and safety extra low voltage safe level < 60V DC as per IEC Standard with LM70 & LM80 certification, complete all as specified and directed. MAKE:- Cat No. LL20-111-XXX-65NE of Wipro / Cat No. ENDURALINEARNEOBS10WLED865SPCWH of Havells or techno-commercially equivlent model in Philips / Bajaj
Security light, IP 66 LED light fitting of capacity 20Watt 240Volt single phase 50Hz consisting of aluminium pressure die-cast housing with high purity PC fresnel diffuser with glass silicon gaskets complete assembly with LED and accessories toughened prewired upto terminal block conforming to IS 10322 Part 5 / Sec 1 : 1967 with in-built integrated electronic LED driver voltage surge protection not less than 3KV, 2/3 stage isolated driver, the LED lumen output colour temperature consistency compliant to LM 6600K standard system lumens of LED luminaire high lumen output minimum 100lm/Watt, with and includig provision of galvanised tubing 40mm dia medium grade not less than 1.50metre length bent to shape including provision of suitable fixing arrangements, complete all as specified and directed. MAKE:- CAT No. LR02-261-XXX-57-XX of Wipro or Cat No. ENDURAPEARLSL20WLED757SASYTOPC of Havells or Techno-commercially equivalent model in PHILIPS / Bajaj
Recessed mounted LED downlighter, 2feet x 2feet size, with housing made up of die-cast aluminium for better thermal management, high transmitivity non yellowing PMMA diffuser for better light output and uniform light distribution without glare, power consumption <= 36W, luminaire lumen > = 3000lm, electronic driver duly wired upto terminal block, CRI > 70, LED Make :- Nichia / Nationstar / Osram / Overlite / Lumiled, with LED binning as per ANSI Bin C78-377A, photo biological safety report as per IEC62471 & electrical insulation class 1, LED life with L70 criteria, colour temperature 6500K, IP 20, 37000 burning hours as per L70 criteria, Ambient temperature-0 to 45 degree Centigrade, THD<10% as per IEC 61000-3-2, driver efficiency > 85%, power factor>0.95, surge protection in CM-2.5KV, two stage isolated constant current operated driver with range 150-270V AC and safety extra low voltage safe level < 60V DC as per IEC Standard with LM 79 & LM 80 certification, complete all as specified and directed. MAKE:- Cat No. CRCO10R038HP57GL1 of Wipro or PLUTONEO2X2PLR34WLED857S of Havells or techno-commercially equivlent model in Philips / Bajaj
Recessed mounted LED downlighter, circular type, with housing made up of die-cast aluminium for better thermal management, high transmitivity non yellowing PMMA diffuser for better light output and uniform light distribution without glare, power consumption <= 15W, luminaire lumen > = 1500lm, LED efficiency > 80lm/W, electronic driver duly wired upto terminal block, CRI > 70, LED Make :- Nichia / Nationstar / Osram / Overlite / Lumiled, with LED binning as per ANSI Bin C78-377A, photo biological safety report as per IEC62471 & electrical insulation class 1, LED life with L70 criteria, colour temperature 6500K, IP 20, 37000 burning hours as per L70 criteria, Ambient temperature-0 to 45 degree Centigrade, THD<10% as per IEC 61000-3-2, driver efficiency > 85%, power factor>0.95, surge protection in CM-2.5KV, two stage isolated constant current operated driver with range 150-270V AC and safety extra low voltage safe level < 60V DC as per IEC Standard with LM 79 & LM 80 certification, complete all as specified and directed. MAKE:- Cat No. LD71-161-SML-65-XX of Wipro or ENDURANEODLR15WLED857MOD of Havells or techno-commercially equivlent model in Philips / Bajaj
Recessed mounted adjustable LED downlighter, circular type, with housing made up of die-cast aluminium for better thermal management, high transmitivity non yellowing PMMA diffuser for better light output and uniform light distribution without glare, power consumption <= 20W, luminaire lumen > = 2000lm, LED effieciency > 100lm/W, electronic driver duly wired upto terminal block, CRI > 70, LED Make :- Nichia / Nationstar / Osram / Overlite / Lumiled, with LED binning as per ANSI Bin C78-377A, photo biological safety report as per IEC62471 & electrical insulation class 1, LED life with L70 criteria, colour temperature 5700K, IP 20, 50000 burning hours as per L70 criteria, Ambient temperature-0 to 50 degree Centigrade, THD<10% as per IEC 61000-3-2, driver efficiency > 85%, power factor>0.95, surge protection in CM-2.5KV, two stage isolated constant current operated driver with range 150-270V AC and safety extra low voltage safe level < 60V DC as per IEC Standard with LM 79 & LM 80 certification, complete all as specified and directed. MAKE:- Cat No. LD56-251-060-40-XX* of Wipro or SPARKLEPROADJDLR20W857MOD40D & LEDDRIVER20WS of Havells or techno-commercially equivlent model in Philips / Bajaj
Fresh air fan 230Volt, 50Hz, single phase AC supply, 200mm sweep with PVC louvers complete with PVC body and PVC blades, with and including provision of 3 core 1.5 Sq.mm flexible cable from ceiling rose to fresh air fan including writing MES number on fresh air fan motor using synthetic enamel paint of approved tint, complete all as specified and directed. MAKE:- USHA / BAJAJ / KHAITAN / HAVELLS
MCCB 4P, 63A, 50Hz with thermal magnetic release Icu = 16KA at 415Volts, Ics = 100% Icu and with adjustable over load (minimum 70% to 100%), complete all as specified and directed.
MCB TPN 32 Amp, 'C' series, 240V, 10KA breaking capacity, complete all as specified and directed.
MCB SP 16 Amp, 'C' series, 230V, 10KA breaking capacity, complete all as specified and directed.
MCB SP 6 Amp, 'C' series, 230V, 10KA breaking capacity, complete all as specified and directed.
MCB SP 3 Amp, 'C' series, 230V, 10KA breaking capacity, complete all as specified and directed.
Sub main wiring complete with 4 runs of 16 sq.mm PVC insulated and unsheathed 1100V grade multistranded FRLS grade copper conductor cable drawn through and including provision of concealed non-metallic rigid PVC conduit 50mm dia and its accessories and connecting terminal ends to DB's including providing 2 runs of 16 sq.mm PVC insulated unsheathed multistranded HRFR grade copper cable as earth continuity conductor and connecting to common earth dolly, complete all as specified and directed. NOTE:- (i) Four runs of 16 sq.mm copper conductor, two runs of 16 sq.mm copper earth continuity conductor and one run of PVC conduit shall be measured as one unit length. (ii) Extra length of cable / wire required for connection to MCBs shall not be measured and the rate quoted per unit shall deemed to be inclusive of the same accordingly.
LAN socket outlet RJ45 with shutter including modur white cover plate with frame, complete all as specified and directed.
Modular metal flush mounting boxes, concealed for mounting of LAN socket up to thre module etc., complete all as specified and directed.
LAN category-6 multi core cable (4-pair unshielded twisted pair cable) with high density polyethylene insulation, paired, fire retardant as IS / IEC 11801, complete all as specified and directed.
Earthing provided in replacement complete with GI earth plate electrode 600mm x 600mm x 6.3mm thick buried directly in ground vertically to a depth of not less than 2.25m deep below ground level with the top edge of earth plate at a depth of not less than 1.5m below ground level connected to GI earth wire of 4mm dia by means of bolts, nuts, washers of galvanised iron or steel, GI earth wire shall be protected by 20mm dia GI pipe 'medium grade', watering pipe 20mm dia GI pipe 'light grade', GI wire meshed funnel, alternate layer of charcoal and salt on all side to earth plate upto a thickness of 150mm, filling of black cotton soil in earth pit upto GL, and connected to earth plate including necessary excavation & earthwork, PCC (1:3:6) type C-1 earth chamber, 50mm thick RCC cover (1:2:4) type B1 mix with 8mm dia nominal reinforcement @ 75mm c/c both ways etc complete all as shown in electrical plate No.3 connected to earthing test point, including testing on completion, complete all as speciified and as directed. NOTE:- (a) Rate quoted shall deemed to include cost of excavation in any type of strata, RFR and removal upto 50metre, PCC pit, funnel and RCC cover plate. (b) Earth continuity conductor beyond 7.5metre shall be measured and paid under respective item of this Schedule.
M/s SRINIVASA CONSTRUCTION COMPANY
M/SLAXMI VENKATEHWARA CONSTRRUCTION
SRI BALAJI INFRA PROJECTS
Raghavendra constructions
Krishna Construction Company
RNR CONSTRUCTIONS
Sai Ram Builders
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .