Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹7.0 LAccepted-AOC VILL PO BUNGWAN KALAN TALBEHAT LALITPUR UTTAR PRADESH 284136 | TALBEHAT | LALITPUR | UTTAR PRADESH | 284136 | 1 | Accepted-AOC LOWEST BIDDER | |
| 2 | 2₹7.7 L+₹45,551 (6.26%)Rejected-Finance VILLAGE TAPARIYAN BABINA CANTT BABINA JHANSI UP 284401 | BABINA | JHANSI | UP | 284401 | 2 | Rejected-Finance NOT LOWEST BIDDER | |
| 3 | 3₹8.3 L+₹1.1 L (14.7%)Rejected-Finance 1442 1 NANADANPURA BABINA CANTT TEHSIL DISTT JHANSI UP | BABINA | JHANSI | UP | 3 | Rejected-Finance NOT LOWEST BIDDER | |
| 4 | 4₹8.4 L+₹1.2 L (15.9%)Rejected-Finance HOUSE NO 164 SHASTRI NAGAR NEAR JAL NIGAM BABINA CANTT DISTT JHANSI UP | BABINA CANTT | JHANSI | UTTAR PRADESH | 4 | Rejected-Finance NOT LOWEST BIDDER | |
| 5 | 5₹8.6 L+₹1.3 L (17.8%)Rejected-Finance CIVIL LINE MATATILA ROAD TALBEHAT DISTT LALITPUR U P | TALBEHAT | LALITPUR | U P | 5 | Rejected-Finance NOT LOWEST BIDDER |
Tender Value
₹10.0 L
EMD Value
₹19,972
Closing Date
12 Feb 2024, 6:00 pmClosed
AJAY KUMAR SINGH
LAKEVIEW CAMP MIL STN TALBEHAT 284125
REPAIR OF U/S LT CABLE, LT ELECT PANELS, SWITCH GEARS AND ALLIED WORKS IN VARIOUS ZONES AT MIL STN TALBEHAT
2024_MES_637514_1
AGE(I)/TBT/TOK-74/2023-24
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
TALBEHAT MIL STN
8 documents required · 8 mandatory
₹500
Yes
AGE I TALBEHAT
₹19,972
15 Mar 2024
15 Jan 2024
14 Feb 2024
22 Jan 2024
12 Feb 2024
29 Jan 2024
Amount
Taking down old damage LT pole including stay assembly of any size and type.
Taking down old ACSR conductor of any size and type.
Taking down old unserviceable GI tubes light grade up to 80mm dia, on place of rusted GI pipe in support of cables.
Taking down old unserviceable stay assembly complete with accessories complete
M&L for Steel tubular swaged poles of 9.0 mtr long, type 410-SP-31 complete with cast iron base plate, finial taper plug, bolts, nuts, painted with two coat of aluminium paint over one coat of red oxide primer on all exposed portion including painted with two coat of sinthetic enamel paint of two different colour of 30 cm wide strip up to 1.5 mtr height from top of PCC coping and numbering of poles with black synthetic enamel paint of size as decided by EIC complete all as spfd and directed by EIC. NOTE:-Excavation, earth work, PCC foundation & PCC coping shall be measured & paid under respective items.
M&L for stay assembly complete with accessories as shown in electrical plate No. 01, dia of stay rod is 20 mm. NOTE:- Earth work and PCC measured and paid seperately under respective items.
M&L for Cement concrete 1:4:8 type D-2 using 40 mm graded stone aggregate for foundations of poles, struts & stay assembly etc all as specified and directed.
M&L for Cement concrete 1:3:6 type C-1 using 20 mm graded stone aggregate as in couping of poles etc including fair finishing the exposed surface even and smooth with out using extra cement and necessary form work all as specified and directed
Excavation in in trenches not exceeding 1.5 mtrs wide & not exceeding 1.5 mtr in depth in soft or loose soil & getting out complete all as spfd & directed.
Removing excavated materialn not exceeding 50mtr &deposited where direceted at a level not exceeding 1.5mtrabove the ground level.
Returning , filling in spreading, levelling, watering & well Ramming in layers not exc 25cm thick complete all as spfd & directed.
Demolition of hard standing/road as per the authorized width as directed including making good the disturbed surfaces and cut to match with the existing surface with PCC 1:2:4, type B-2(using 40mm graded crushed stone aggregate) including removing demolished materials complete all as specified and directed.
Supply & Laying un reinforced precast concrete cable cover, Class HVP type-2 flat size 250 mm x 150 mm x 40 mm for cable protection laid length wise perpendicular to the adzes of cable complete all as specified and directed.
Supply and laying m-sand for cushioning to underground cable in layers of 23 cm (8 cm deep before laying of cable and 15cm deep over the cable) after laying the cable in trenches including punning thickness up to 18 cm , complete all as specified and directed.
M&L in replacement of cable XLPE insulated heavy duty electric cables with Stranded alluminium conductor, 1100 volts grade, passing through trenches/ducts/pipes and climbing on poles/walls including fixing with proper size of alluminium lugs. For the following sizes. NOTE:- 1. Excavation and earth work to be measured and paid separately.
25 Sq mm 3.5 Core.
120 Sq mm 3.5 Core.
150 Sq mm 3.5 Core.
400 Sq mm 3.5 Core.
Supply and laying or fixing in replacement GI tubes light grade 40 mm dia, on place of rusted GI pipe in support of cables, on pole/wall/laid in floor/in trenches incl cutting of road, PCC etc.
Supply and laying or fixing in replacement GI tubes light grade 80 mm dia, on place of rusted GI pipe in support of cables, on pole/wall/laid in floor/in trenches incl cutting of road, PCC etc.
Taking down old unserviceable light fitting of any type and wattage.
Labour only for attending of street/security light complaints taking down from pol and refixing same after repair and repair other misc E/M wks, checking of existing electrical circuits i.e. LT OH and UG cable, nature switches & other accessories, P/B, MCCB incomer/out going etc. for continuous electrical supply, detection of nature of fault/defect carrying out minor repairs etc. as required to make the items functional and incl tightening of loose connections, taking down lights and refixing the same after necessary repairs, replacing defective items provided under relevant items of issue only from MES store. The item rate included for repairs items/materials i.e. fuse, thimbles, small wires of any size and description upto 0.5 mtr, screw washer etc., along with all items for complaint, suitable T & P, safety equipment & other necessary device, every day excl Sunday and Holiday complete all as specified and directed.
Supply, fixing and testing high prformance LED Street Light fittings of 72 Watts, energy saving and environment friendly long life pressure die -cast aluminium hosing high power LED as lighting source and lens embedded PC cover having TOP OPENING separate driver compartment with IP-66 Protection and impact resistance of IK07 with 10KV Built-in-Surge Protection Device suitable for pole dia 54 mm complete all as specified and directed ,MAKE : Havells/Philips/Surya/Crompton
Repair/Maintenance/Servicing of gang operated device 11 KV fix on four pole/Two pole by replacement of fix and moving contact, flexible copper jumper etc as required for make serviceable for proper on/off operation complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in repair MCCB, 415 volt, adjustable type, 36KA, 4 pole, capacity 200 Amp including taking out old unserviceable MCCB from Elect panel complete.
Supply and fixing in repair MCCB, 415 volt, adjustable type, 36KA, 4 pole, capacity 250 Amp including taking out old unserviceable MCCB from Elect panel complete.
Supply and fixing in repair MCCB, 415 volt, adjustable type, 36KA, 4 pole, capacity 400 Amp including taking out old unserviceable MCCB from Elect panel complete.
Note :- Debris obtained from all items should be removed in low lying areas as directed by Engr-in-charge out of MOD Land. (Rates quoted for items are deemed to be included for this, where removal of debris in the items is not considered.)
M/S Kharya Associates
M/S SHIVA TRADERS
m/s bobby enterprises
HARNAM SINGH ANIL SINGH
A S ENTERPRISES
stage.html
html • 0.06 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .