Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.8 LAccepted-AOC 315 INDUSTRIAL AREA II PANCHKULA 134113 | PANCHKULA | HARYANA | 134113 | L1 | Accepted-AOC accepted | |
| 2 | L2₹16.4 L+₹57,986 (3.67%)Rejected-AOC 1128 SECTOR 22 B NEAR AROMA PETROL PUMP CHANDIGARH UT 160022 | CHANDIGARH | CHANDIGARH | 160022 | L2 | Rejected-AOC rejected |
Tender Value
₹18.3 L
EMD Value
₹36,680
Closing Date
5 Jul 2021, 5:00 pmClosed
Executive Engineer
Electrical Division PWD BnR Rohtak
Construction of Teaching Block at Regional Center Kharal (Jind) at BPSMV, Khanpur Kalan (Pdg. Fire Alarm System only)
2021_HRY_175807_1
PWD/Electrical/94697
Open Tender
Electrical Works
Item-rate/Agreement basic
60 days
Jind
Please refer to tender documents as per DNIT conditions.
3 documents required · 3 mandatory
₹1,000
₹36,680
Yes
5 Oct 2021
15 Jun 2021
6 Jul 2021
15 Jun 2021
5 Jul 2021
15 Jun 2021
Amount
SITC of Micro processor based 2 wire fault tolerant, networkable type Fire Alarm / Detection Control Panel (having nos. of loops to suit minimum 20% extra over the nos. of fire detectors. The panel shall be able to give location of all fire / fault conditions of addressable units via the address codes. Further, the panel must be able to automatically switch ON/OFF respective control module when ever any alarm is triggered. The panel shall have rectifier, loop cards, minimum 160 characters LCD unit/ 5.7’’TFT to indicate Fire / Fault Signal with address and analog output, external/inbuilt printer to log all fire or fault events complete in all respects. The Panel Shall be sheet Steel power coated, sealed to IP30. The Panel shall have 20 Zones with individual LED Indicators, expandable to 80 LED Indicators. The Panel shall have 3 Serial Ports. The pane\l shall have a built in power supply and battery charger along with maintenance free 24 AH,2 x 12 volt SMF lead acid batteries capable of running for a minimum of 24 hours with battery charger complete as required. And conforming to BS5839 standards and Duly Approved by EN 54/UL/VDS/ as per specifications complete in all respect up to the entire satisfaction of Engineer-in –charge of work. Make: Bosch FPA 1000 / Cerberus by siements/ Edwards EST3/Honeywell Morley Zxe series
SITC of 6 watt ceiling / wall mounted speaker complete in all respect. Make:-Bosch / Honeywell / Ahuja / Aties
SITC of Analog Addressable type Active Repeater fire alarm panel with Backlit LCD Display, having controls for reset, mute, Accept, Silence alarms and self test conforming to BS5839 standards and Duly approved by EN54/UN54/VDS with all labour and material required to complete the job in all respect up to the entire satisfaction of Engineer – in Charge of work.Make :- Bosch / Siemens Cerberus / Honeywell / Edward
SITC of addressable multi sensor detector with a combination of optical and thermal including base, auto addressing features as required. Detectors should have 2 as per NFPA 72 style 7 wiring requirements (one for incoming and one for outgoing line) for maintaining operational availability of all elemnets in the loop in the event of a short circuit and to meet style 7 requirements. High resistance to electromagnetic effects in accordance wiht EFSG agreement EFSG/F/97/005. EMC safety for detector shall be 50 V/m. shall be EN54/VDS/UL certification. ((Detectors without inbuilt isolators may be considered with an additional isolator module after 20 devices) Make: Bosch FAP-440+T+FAA-440, Siemens Cerberus OH921+DB-11, Honeywell Morley HM-PTSE+B501, Edwards SIGA PHD+SIGA
SITC of addressable Heat Detector wht fixed and rate of raise feature including mounting base with LED etc complete as required. Each detector should have 2 as per NFPA 72 style 7 wiring requirement (one for incoming and one for outgoing line) for maintaining operational availability of all elements in the loop in the event of a short circuit and to meet style 7 requirements. High resistance to eletrmagnetic effects in accordance with EFSG agreement EFSG/F/97/005. Detector should monitor electromagnetic interfarence and report to the panel-current and average values, EMC safety for detector shall be 50 V/m. shall be EN54/VDS/U: certification. (Detectors without inbuilt isoaltors may be considered with an additional isolator module per detector. Make: Bosch FAH-440+FAA-440, Siemensr Cerberus HI921+DB-11, Honeywell Morley MI-RHSE+B501, Edwards SIGA DHI+SIGA
SITC of UL/EN54/LPCB listed and FM approved line isloating for isolation the section of circuit in case of short in the addressable loop wiring complete in all respect. (Make: Bosch / Siemens Cerberus/ Morley / Edwards)
SITC of intelligent analog addressable type Manual Call point having surface or flush mounting option fully compliant to EN54 having rotary decade switches for addressing with back box for mounting as required conforming to BS5839 standards and duly approved by EN54/UL/VDS required to complete the job in all respect upto the entire satisfaction of Engineer-in-Chage of the work.Make Siemens cerberus/ Morely/ Edwards
SITC of addressable Loop powered hooter with strobe complete with mounting base as required conforming to BS5839 standards and duly approved by EN54/UL/VDS required complete the ob in all respect upto the entire satisfaction of Engineer - in - charge of work. Make Bosch/ Morley/ Siemens/ Cerberus/ Edward
SITC of Glow Type EXIT Sign Board photo luminescent of size 300 mm x 250 mm x 1.5 mm rigid sheet signage containing Zink sulphate as bare chemical class 1 material PSPA fixed on 3mm acrylic sheet on both side showing marking (running man, Arrow and Exit) and hanged with the ceiling with chain and fastener incluing all accessories upto the entire satisfaction of Engineer-in-Charge of the work. Make:- GLOLITE / PEARL / DEVI
SITC of Addressable Control Relay Module with flexible network structures with a maximun switching current of 1A @ 30V DC. Shall be EN54/UL/VDS Certification Makes :Bosch /Siemens Cerberus / Morley / Edwards
SITC of Intelligent Analog Addressable Type Monitor Modules having option of RAIL or Surface Mounting with Tri Color LED status indicator with Built in Short Circuit Isolators having Visible Rotary Decade Address Switch from 01-99 dully approved to GEA GEW1-082 conforming to BS5839 Standards and Duly approved by EN54/LPCB/VDS with all labour and material required to complete the job in all respect up to the entire satisfaction of Engineer-in-Charge of work. Makes: Bosch- FLM - 325 - 214, Siemens cerberus HTRI-M,Morley MI-DMMI, Edwards EST3
SITC of minimum 1000 Mtr. Range Kheraj / National make SIRON generator provided at the roof of the building with separate Power SITC, relay complete in all respect. Make National / Kheraj
Supply and Erection of Fire Extenguishers duly hang on wall with necessary hook complete in all respect. Make: Safex / Minimax / Cease Fire)
ABC dry Powder extinguisher 6 Kg Cap
Water CO2 9Ltr Cap
CO2 type 4.5kg cap
Supply and erection of PVC unsheathed copper conductor cable two core 1100 volts grade in pipe of suitable size excluding cost and erection of pipe (based on HSR). Make :- Havells /Polycab/Finolex
Size 1.5 sq.mm
SITC of PVC conduit pipe ISI marked (medium) recessed in wall/ ceiling etc. including cost of PVC bends, inspection box and all other material required to complete the job in all respect to the entire satisfaction of Engineer -in-charge of the work ( Based on HSR) Make: BEC, AKG, Kalinga / Di plast
25 mm Dia
SITC of 2x1.5sqmm Twin twisted speaker Cable complete in all respect. Make:- Polycab / Fenolex / Kalinga
SITC of 2KVA online UPS with external SMF batteries 12V fo suitable AH battery for minimum 2 hour backup Make:- Microtek / EMERJON / APC / Libert
Tele Net Marketing Pvt Ltd
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .