Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.4 LAccepted-AOC | L1 | Accepted-AOC Accepted | |
| 2 | L2₹19.1 L+₹1.7 L (10.1%)Rejected-Finance WARD NO 40 REGRON KA MOHALLA NEAR RAVI DASS JI MANDIR SHIV BARI BIKANER RAJSTHAN 334001 | BIKANER | RAJASTHAN | 334001 | L2 | Rejected-Finance Not Lowest Bidder | |
| 3 | L3₹19.4 L+₹2.1 L (12.0%)Rejected-Finance | L3 | Rejected-Finance Not Lowest Bidder | |
| 4 | L4₹19.5 L+₹2.1 L (12.3%)Rejected-Finance C O SHRI AMRENDER KUMAR YADAV IACHHIPUR SANTOSH NAGAR GORAKHNATH GORAKHPUR UTTAR PRADESH PIN 273015 | GORAKHPUR | UTTAR PRADESH | 273015 | L4 | Rejected-Finance Not Lowest Bidder | |
| 5 | L5₹20.8 L+₹3.4 L (19.7%)Rejected-Finance | L5 | Rejected-Finance Not Lowest Bidder |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
27 Oct 2022, 6:00 pmClosed
GE ARMY SURATGARH
SURATGARH MIL STN
Repair / maintenance of street light fittings and connected items in ILP / KLP area under GE (Army) Suratgarh at Suratgarh Mil Stn
2022_MES_555315_1
GE (A) SOG - 58/22-23
Open Tender
Electrical and Maintenance Works
Item Rate
240 days
SURATGARH
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE ARMY SURATGARH
₹60,000
Yes
7 Nov 2022
30 Sept 2022
29 Oct 2022
30 Sept 2022
27 Oct 2022
14 Oct 2022
Amount
Taking down complete high mast light fitting including 150-200 watt flood light for finding out faults and refixing the same in existing position after carrying out necessary repair and wiring with 4 sqmm 3 core copper PVC cable, tightning of loose connection and cleaning of glass complete all as specified and directed by Engineer-in-Charge. Notes :- (i) Ladder wheel shall be arranged by the Contractor. (iii) Detection and rectification of fault in over head/under ground line shall be done by the contractor.
Inspection/Checking of street light fitting 30/45/60/72/90 watt LED light fittings etc for tighting the connection with replacement of twin core multi stranded 1.5 sqmm aluminium wire complete all as specified and directed by Engineer-in-Charge. Notes :- (i) Ladder wheel shall be arranged by the Contractor. (ii) The cost of wire replaced will not be paid seprately in over head conductors.
Taking down street light fitting upto 30/45/60/72/90 watt LED light fittings etc for finding faults including cleaning glass with castic soda solution and refixing the same in existing position after carrying out necessary repair / replacement of unserviceable parts complete all as specified and directed by Engineer-in-Charge. Notes :- (i) The accessories / spare parts which are required to be replaced shall be measured and paid for separately as “Supply only” under srl item No 4 to 9 of BOQ here-in-after. (ii) Ladder wheel shall be arranged by the Contractor. (iii) Detection and rectification of fault in over head/under ground line shall be done by the contractor.
Supply only in replacement electronic driver 220/240 volts suitable for existing LED Street light fitting 45 watts complete all as specified and directed by Engineer-in-Charge. Make :- Wipro / Philips / Syska / Crompton / Surya or equivalent in makes mentioned in Appendix 'A' here-in-after.
Supply only in replacement electronic driver 220/240 volts suitable for existing LED Street light fitting 60 watts complete all as specified and directed by Engineer-in-Charge. Make :- Wipro / Philips / Syska / Crompton / Surya or equivalent in makes mentioned in Appendix 'A' here-in-after.
Supply only in replacement electronic driver 220/240 volts suitable for existing LED Street light fitting 72 watts complete all as specified and directed by Engineer-in-Charge. Make :- Wipro / Philips / Syska / Crompton / Surya or equivalent in makes mentioned in Appendix 'A' here-in-after.
Supply only in replacement electronic driver 220/240 volts suitable for existing LED Street light fitting 90 watts complete all as specified and directed by Engineer-in-Charge. Make :- Wipro / Philips / Syska / Crompton / Surya or equivalent in makes mentioned in Appendix 'A' here-in-after.
Supply only in replacement 10 KV surge protector suitable for LED fittings 45 / 60 / 72 / 90 watts complete all as specified and directed by Engineer-in-Charge. Make :- Crompton Cat part No SRPSQ-10KV/5KA-440 or equivalent in makes mentioned in Appendix 'A' here-in-after.
Supply only in replacement weather proof PVC insulated, sheathed three core stranded aluminium conductor cable of size 2.5 Sqmm, 1100 Volts grade conforming to IS:9968 (Part-I) 1988 or IS:694-1990 complete all as specified and directed by Engineer-in-Charge.
S&F in replacement street light bracket made out of 32mm dia GI pipe light grade 1.2m long , bent to shape at 120 degree angle from vertical fixed along pole with and including required number of clamp made out of Flat iron 25mm x 6mm with nuts, bolts ,washers etc. duly painted with two coats of aluminium paint over a coat of red oxide primer complete all as specified and as directed by Engineer-in-charge.
Supply and fixing in replacement energy efficient LED street light fitting of 45W pressure die cast aluminium housing/body, heat resistant clear toughened glass, better optics for uniform distribution street/Roadway luminaire, with driver, including electric connection, complete fitting with all accessories and following specifications and all as directed by Engr-in-Charge :- (a) Lumen system efficacy of luminaire should be minimum 110 Lumen per watt. (b) Input Voltage range : 140 to 270 volts (c) Temp operating range : Minus 10°C to Plus 50°C (d) Power factor : Minimum 0.95 (e) THD : Max10%. (f) CRI : Morethan 80 and CCT : 5700 K. (g) IP rating : IP66. (h) IK rating : Minimum IK07 (j) Built in potted LED Driver of the make as of the luminaire. (k) LED driver should be complete with all protections viz open/short circuit protection, over voltage protection, all as per standard design of manufacturer. (l) Surge protection 10 kV (inbuilt + extended) (m) Lens - High Efficiency wide angle lens. (n) BIS Approved fixtures and driver (o) Rated life time : 50000 burning hrs (Average 10 to 12 hrs daily) Make :- Havells / Crompton / Wipro or equivalent in makes mentioned in Appendix 'A' here-in-after.
All as per Srl item No 11 above but LED street / security light of 60 watt Notes for srl Item No 11 & 12 :- (a) Tenderer shall submit test report of LED street light fitting from Government accredited test laboratory for LM - 79 and LM - 80 . (b) Contractor has to furnish a replacement warranty of 05 years for LED light fittings complete including lamps from the date of completion of CA. Contractor shall obtain warranty from the manufacturer of product on their letter head and submit the same to deparment alonwith his letter head. The product will be replaced free of cost in the following case :- (i) Manfacturing defects (ii) Failure due to mechanical and electrical impact. (iii) Drop in lumen (or lux at 1 m) below 90% of clamied values of lumen(or lux at 1 m) of the LED /Luminaries. (c) All LED light/luminare must meet the provision laid down in IS - 16101 , 16102 Part -I/II ,16103 Part -I , 16104 ,16105 ,16106 , 16108/2012 and 15885 Part -II / Section 13. (d) Scope of work shall include supply and fixing street light fittings on street light bracket fixed on poles, If street light fitting requires to fixed on existing street light bracket and any addition alterration required in bracket for fixing street light, In that case cost of additional / alteration is included in the unit rate of this item, which also includes needful T & P and required accessories such as 1.5 sqmm, 3 core PVC insulated stranded copper conductor cable for connection from pole box to light fitting etc complete including making connection, testing etc complete .No extra payment is admissible on this account. (e) Light fittings shall be provided with 10 KV surge protection as mentioned in description of item. If 10 KV surge protection is not provided in light fitting for which cat part is mentioned in BOQ. Contractor has to provide light fitting with 10 KV surge protection without any extra cost to department. (f) Contractor shall write CA No on street light fitting with synthetic enamel paint which should be visible from ground level. Cost of the same is included in the unit rate of this item nothing shall be extra paid on this account.
S&F in replacement LED flood light of 160 watt with high pressure die cast housing with lens with lument output 6000K complete (including LED, drive and internally prewired) with on board 5 KV surge protection with 10 KV external SPD. The luminaries shall be monolithic construction totally enclosed dust and water proof with minimum IP 65 protection as per IS 10322-1982 (part-I) with latest amanedments and input voltage range 140-300V AC, frequency 50-60 Hz, P.F should be more than 0.9. The efficiency of LED luminaries system shall be more than 100 lumens per watt and FRLSH cable PVC insulated stranded copper conductor, 1100 volts grade, 2.5 sqmm x 3 core of ISI marked for light to ceiling rose complete including arrangement of mounting for street light as required at site complete all as specified and directed by Engineer-in-charge. Make :- Bajaj Cat part No BARFEG 160W LED / Wipro / Philips / Havells or equivalent in makes mentioned in Appendix 'A' here-in-after.
S&F in replacement LED post top 35 watt decorative circular design energy saving, IP 65 protection environmental freindly, long life aesthetically designed with symmetrical light distribution, cast aluminium body landscape luminaire with high power LEDs with polycarbonate type diffuser including two coat of black painting on existing post and cement work in base stand (spigot housing with decorative opal acrylic diffusser and IP 65 protection with all accessories complete all as specified and as directed by Engineer-in-charge. Make :- Havells cat part No RUBYPT35WLED830 PSYMTOPC / Crompton or equivalent in makes mentioned in Appendix 'A' here-in-after.
S&F in replacement three phase automatic street light switch suitable for 5 KW load complete with Infrared sensor based NATURE SWITCH for automatic switching of street / security lights with three number two pole power contractors 40 Amps (Type - MU40-2P, Cs90119) with coil voltage 220 / 240 V and incoming MCBs single pole - 03 Nos, outgoing MCBs single pole - 03 Nos of rating 32 Amps & circuit wiring with single core multi stranded of size 10 Sqmm. Lighting switch operation should be based on natural light lux level. Required illuminance level for switching ON is < 30 Lux and for switching OFF > 10 Lux. The sensor should also have part night operation facility for 4,5,6,........11 & 12 hours. The sensor along with suitable power contactor (S), Incoming -outgoing MCB's should be enclosed in a Rust proof, electric shock proof, termite proof and FR grade thermoplastic polycarbonate enclosure with hinged lid confirming to IP66 protection class 2. The circuit should also have provision for manual operation (i.e. sensor By-pass option). The enclosure should be pole / wall mounted complete all as specified and directed by Engineer in charge. Make :- KAKATIYA ENERGY SYSTEM PVT LTD (Swadeep 02EC3KW1P) or equivalent in makes mentioned in Appendix 'A' here-in-after
S&F in replacement Single phase automatic street light switch suitable for 3 KW load complete with Infrared sensor based NATURE SWITCH for automatic switching of street / security lights with one number two pole power contactor 40 Amps (Type - MU40-2P, Cs90119) with coil voltage 220 / 240 V and incoming MCBs single pole - 01 No, outgoing MCBs single pole - 01 No of rating 32 Amps & circuit wiring with single core multi stranded of size 10 Sqmm. Lighting switch operation should be based on natural light lux level. Required illuminance level for switching ON is < 30 Lux and for switching OFF > 10 Lux. The sensor also have part night operation facility for 4,5,6,........11 & 12 hours. The sensor along with suitable power contactor (S), Incoming -outgoing MCB's should be enclosed in Rust proof, Electric shock proof, termite proof and FR grade thermoplastic polycarbonate enclosure with hinged lid confirming to IP66 protection class 2. The circuit should also have provision for manual operation (i.e. sensor By-pass option). The enclosure should be pole / wall mounted complete all as specified and directed by Engineer in charge. Make :- KAKATIYA ENERGY SYSTEM PVT LTD (Swadeep 02EC3KW1P) or equivalent in makes mentioned in Appendix 'A' here-in-after
S&F in replacement street light pole box of size not less then 300x200x105mm, made of high quality thermo plastic polystyrene, weather proof, dust, jet water proof, chemical, acid corrosion, impact, insulated & shock proof IP 65 for outdoor Installation with internallly embedded gasket (PUR) including MCB SP 6 Amps 01 No along with left side hinge door (notch arrangement not acceptable) & premoulded knockout all sides including back of the base must. The box fitted with 10 sqmm stud type terminal - 04 Nos including Elimex stud type TB 4 Nos. Note :- (i) Cost of flat iron clamp is deemed to included in unit rate of this items. Nothing extra shall be paid on this account. (ii) Size of junction box for different mafufacturer may slightly varried from size mentioned in description of item. Contractor has to provide junction box as per cat No mentioned against make of junction box. where cat No is not mentioned against any make, in that case junction box of size mentioned in description has to provide, if exact size of junction box is not available, then next higher size junction box has to be provided. Nothing extra shall be paid on this account.
S&F in replacement power contactor two pole of capacity 40 Amps, suitable for MU40-2P with 220/240V, wide band coil complete all as specified and directed by Engineer-in-Charge.
Inspection/checking of APFC panel 3 phase, 440 voltage 50 Hz AC supply system to improve power factor 0.80 to 0.98 automatic step wise switched capacitor panel to make it serviceable with the help of connecting relays, capacitors, contactors, MCB's, CT's etc and rectifying the defects, replacement of unserviceable part as required at site and cleaning of AMF panel as detecting during inspection or pointed out by users/department and carry out maintenance complete all as specified as directed by Engineer-in-charge. Note:- Spare parts required shall be measured and paid for separately under respective items of BOQ as supply only..
Supply only in replacement of AIPFC micro processor based relay 4 Stage PFC CONTROLLER-BR-4904-04 ST RELAY 230V complete all as specified and as directed by Engineer in charge.. Make - L & T /GE / EPCOS / Siemens / Crompton or equivalent in makes mentioned in Appendix 'A' here-in-after.
Supply only in replacement of AIPFC micro processor based relay 8 Stage PFC CONTROLLER-BR-4000-08 ST RELAY 230V complete all as specified and as directed by Engineer in charge.. Make - L & T /GE / EPCOS / Siemens / Crompton or equivalent in makes mentioned in Appendix 'A' here-in-after.
Supply only in replacement of AIPFC micro processor based relay 12 Stage BR6000 SERIES 12 STP RELAY 230V complete all as specified and as directed by Engineer in charge.. Make - L & T /GE / EPCOS / Siemens / Crompton or equivalent in makes mentioned in Appendix 'A' here-in-after.
Supply only in replacement of Heavy duty Capacitor 3 Phase, 415Volt (AC), 50 HZ of cap 1 KVAR complete all as specified and as directed by Engineer in charge. Make - Epcos Cat part- B32447A4012B 40 / GE/L& T / Siemens / Crompton or equivalent in makes mentioned in Appendix 'A' here-in-after.
Supply only in replacement of Heavy duty Capacitor 3 Phase, 415Volt (AC), 50 HZ of cap 2 KVAR complete all as specified and as directed by Engineer in charge.. Make - Epcos Cat part- B32447A4022B 40 / GE / L& T / Siemens / Crompton or equivalent in makes mentioned in Appendix 'A' here-in-after.
Supply only in replacement of Heavy duty Capacitor 3 Phase, 415Volt (AC), 50 HZ of cap 3 KVAR complete all as specified and as directed by Engineer in charge.. Make - Epcos Cat part- B32448A4032B 40 / GE/L& T / Siemens /Crompton or equivalent in makes mentioned in Appendix 'A' here-in-after.
Supply only in replacement of Heavy duty Capacitor 3 Phase, 415Volt (AC), 50 HZ of cap 4 KVAR complete all as specified and as directed by Engineer in charge. Make - Epcos Cat part- B32448A4042B 40 / GE / L& T / Siemens /Crompton or equivalent in makes mentioned in Appendix 'A' here-in-after.
Supply only in replacement of Heavy duty Capacitor 3 Phase, 415Volt (AC), 50 HZ of cap 5 KVAR complete all as specified and as directed by Engineer in charge. Make - Epcos Cat part- B32448A4052B 40 / GE / L& T / Siemens /Crompton or equivalent in makes mentioned in Appendix 'A' here-in-after.
Supply only in replacement of Heavy duty Capacitor 3 Phase, 415Volt (AC), 50 HZ of cap 10 KVAR complete all as specified and as directed by Engineer in charge. Make - Epcos Cat part- B32448A4102B 40 / GE / L& T / Siemens / Crompton or equivalent in makes mentioned in Appendix 'A' here-in-after.
Supply only in replacement of Heavy duty Capacitor 3 Phase, 415Volt (AC), 50 HZ of cap 12.5 KVAR complete all as specified and as directed by Engineer in charge.. Make - Epcos Cat part-B32448A4122B540 / GE / L& T / Siemens / Crompton or equivalent in makes mentioned in Appendix 'A' here-in-after.
Supply only in replacement of Heavy duty Capacitor 3 Phase, 415Volt (AC), 50 HZ of cap 15 KVAR complete all as specified and as directed by Engineer in charge.. Make - Epcos Cat part- B32448A4122B540 / GE / L& T / Siemens /Crompton or equivalent in makes mentioned in Appendix 'A' here-in-after.
S&F in repair of Heavy duty Capacitor 3 Phase, 415Volt (AC), 50 HZ of cap 25 KVAR complete all as specified and as directed by Engineer in charge.. Make - Epcos Cat part- B32448A4252B 40 / GE / L& T / Siemens /Crompton / Epcos or equivalent in makes mentioned in Appendix 'A' here-in-after.
Supply only in replacement of Capacitor duty contactors 3 Phase suitable up to 10 KVAR cap Duty cont 1 NO1NC240V complete all as specified and as directed by Engineer in charge.. Make - EPCOS Cat Part No B44066S1011C240N 1 or equivalent in makes mentioned in Appendix 'A' here-in-after.
Supply only in replacement of Capacitor duty contactors 3 Phase suitable up to 16 KVAR cap Duty cont 1 NO1NC240V complete all as specified and as directed by Engineer in charge. Make - EPCOS Cat Part No B44066S1611C240N 1 or equivalent in makes mentioned in Appendix 'A' here-in-after.
Supply only in replacement of Capacitor duty contactors 3 Phase suitable up to 25 KVAR cap Duty cont 1 NO1NC240V complete all as specified and as directed by Engineer in charge.. Make - EPCOS Cat Part No B44066S2511C240N 1 or equivalent in makes mentioned in Appendix 'A' here-in-after.
S&F in replacement MCB 6 to 32 Amps, Single Pole 240 Volts, 10 KA, ‘C’ Curve, complete all as specified and directed by Engineer-in-charge. Make :- Legrand Cat Part No 408587 to 408595 or equivalent in makes mentioned in Appendix 'A' here-in-after.
S&F in replacement MCB 32 Amps, 3 pole, C curve, 10 KA complete all as specified and as directed by Engineer in charge.. Make: - Legrand Cat Part No: - 408658 or equivalent in makes mentioned in Appendix 'A' here-in-after.
S&F in replacement MCB 40 Amps, 3 pole, C curve, 10 KA complete all as specified and as directed by Engineer in charge.. Make: - Legrand Cat Part No: - 408659 or equivalent in makes mentioned in Appendix 'A' here-in-after.
Supply only in replacement of current transformer of ratio 100/5, 5 VA with accuracy class 1.0 including connection with 2.5 sqmm twin core PVC cable complete all as specified and as directed by Engineer in charge.
Supply only in replacement of current transformer of ratio 200/5, 10 VA with accuracy class 1.0 including connection with 2.5 sqmm twin core PVC cable complete all as specified and as directed by Engineer in charge.
M&L for painting on steel tubular poles 9 metre long including attachments (cross arms, clamps GI pipes etc) complete with one coat of aluminium paint after preparation of steel surfaces and black & yellow strips 30cm each upto 1.5 metre height from top of PCC foundation block or PCC coping including numbering of poles with synthetic enamel paint (Black) in 80mm high letters over 150mmx230mm yellow base complete all as specified and directed by Engineer-in-charge.
M&L for preparation of old painted surfaces of PCC pole and applying two coats of synthetic enamel paint in black and yellow colour in alternate strips of 30 cm each upto 1.50 metre height from top of PCC coping and applying two coat of aluminum paint over cross arms, brackets, bracings, clamps, hooks etc. and marking pole number with white synthetic enamel paint in 80mm high letters, over black synthetic enamel paint base of size 20cm x 20cm including applying two coats of white wash to coping of poles all as specified and directed by Engineer-in-Charge. Note :- Pole number shall be marked with white enamel paint over a base of size 20cm x 20cm prepared with two coats of black enamel paint on pole surfaces.
M & L for PCC (1:2:4) type B-1 using 20 mm graded stone aggregate as in coping of poles etc including weathering, slightly rounded or chamfered angle and throating, necessary form work and fair finishing all exposed faces of concrete without using extra cement complete all as specified and directed by Engineer-in-charge
Supplying, laying, jointing, comissioning of PVC insulated, armoured, heavy duty electric cable with aluminium conductor, 1100 volts grade, cross sectional area 25 sqmm 4 core confirming to IS : 1554 (Part-I 1988) laid in tenches along polesthrough pipe etc including taking down old unserviceable cable complete all as specified & as directed by Engineer –in-charge. Notes :- (i) Excavation, earth work, sand cushioning, cable protection and GI pipe shall be measured & paid for separately under respective items of BOQ (ii) Road cutting / floor cutting /cutting holes etc in walls required for laying/fixing of cable etc shall be made good as per existing. Nothing extra shall be admissible on this account. Quoted rates shall deemed to be inclusive of the above provisions.
All as per item No 43 above but cable of cross sectional area 16 sq mm 4 core
All as per item No 43 above but cable of cross sectional area 16 sq mm 2 core
Cutting/ trimming of tree branches not exc 10cm girth touching/approaching the LT / HT overhead lines upto 3 metre width on each side with hacksaw/axe to clear the LT / HT line including disposal of trimmed branches 100 Metre away inside the cantonment area & clearing site complete all as specified and directed by Engineer-in-Charge. (Approximate length of span 40 to 50 metre) Note:-The contractor shall be responsible to maintain this item of work till the date of completion work. Nothing shall extra be paid on this account.
Taking out old unserviceable underground LT Cable with standad aluminium conductor 1100 volts grade cross sectional area upto 95 Sqmm form trenches / floor / road / pipe / along poles and relaying in the same location after repair complete all as specified and directed by Engineer-in-Charge. Note : Excavation & earthwork shall be measured and paid seperately under respective items of BOQ.
Excavation in trenches, not exc 1.5 m wide and n. exc 1.5 m depth, or n exc 10 Sqm on plan and n exc 1.5 m in depth for foundations of poles, struts, stays etc. or laying underground cable and water supply / sewage pipe line etc. in soft / loose soil & getting out including taking out old brick or precast cable cover complete all as specified and directed by Engineer-in-Charge.
Returning, filling in, including spreading, leveling watering and well ramming in layers n.exc 25 cm in soft/loose soil complete all as specified and directed by Engineer-in-charge.
Removal of excavated soil/ material to a distance not exc 50 metre and depositing where directed at a level not exc 1.50 metre above the starting point complete all as specified and directed by Engineer-in-charge.
M&L for dry sand (Tibba sand) and punning for cushioning to underground cable complete all as specified and directed by Engineer-in-charge Note: - For payment purpose thickness after punning shall be measured.
M & L for brick protection with old size sub class 'B' bricks laid flat, length of bricks across the route of underground cable all as specified and directed by Engineer-in-Charge.
S&F in replacement Galvanized iron tubing, 50mm bore light grade, ISI marked, including all fittings and laid in trenches / under road / drains, fixed to poles / walls with required numbers of clamps made out of 25x3mm flat iron, bolts, nuts and washers for protection of LT electric cable complete all as specified and as directed by Engineer-in-charge. Notes :- (i) Excavation & earthwork shall be measured & paid for separately under respective items of BOQ (ii) Cost of flat iron clamp if required is included in the unit rate of this item. Nothing extra shall be paid on this account.
All as per item No 53 above but 40mm bore tubing ----------------------------------------------------------------------------- Note :- A sum of Rs. 154066/- will be deducted on account of credit for dismantled/ demolished / taken down material. Please refer details on Srl Page No. 28 & 29 (Schedule of Credit) of Tender documents.
B.K. ROY & SONS
DASHMESH ENTERPRISES
SHIVA BUILDERS
Gupta Suppliers
08AASFJ0437G1Z8
M/s Rohit Construction Co.
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .