Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.6 CrAccepted-AOC 20 SC BOSE COLONY GALL NO 2 DEFENCE LAB ROAD RATNADA JODHPUR 342001 | JODHPUR | JODHPUR | RAJASTHAN | 342001 | ₹4.6 Cr Quoted ₹4.7 Cr | L1 | Accepted-AOC Being lowest bidder |
| 2 | L2₹4.7 Cr+₹6.1 L (1.30%)Rejected-Finance 205 PARSHAV VIHAR PLOT NO 50 1 P EXTN PATPARGANJ DELHI 110092 | DELHI | EAST DELHI | DELHI | 110092 | ₹4.7 Cr+₹6.1 L (1.30%) | L2 | Rejected-Finance Other than lowest bidder |
| 3 | L3₹5.3 Cr+₹67.5 L (14.5%)Rejected-Finance C 101 ADG P CHENNAI | ₹5.3 Cr+₹67.5 L (14.5%) | L3 | Rejected-Finance Other than lowest bidder |
| 4 | L4₹5.6 Cr+₹92.7 L (19.9%)Rejected-Finance 13 29 3RD FLOOR EAST PATEL NAGAR NEW DELHI 110 008 | WEST | DELHI | 110008 | ₹5.6 Cr+₹92.7 L (19.9%) | L4 | Rejected-Finance Other than lowest bidder |
| 5 | L5₹5.8 Cr+₹1.1 Cr (23.7%)Rejected-Finance | ₹5.8 Cr+₹1.1 Cr (23.7%) | L5 | Rejected-Finance Other than lowest bidder |
Tender Value
Refer Docs
EMD Value
₹6.7 L
Closing Date
20 Jan 2021, 6:00 pmClosed
CE Jodhpur Zone
HQ CE Jodhpur Zone
AUGMENTATION AND IMPROVEMENT OF STATION ELECTRICITY SUPPORT STRUCTURE, IMPROVEMENT OF ELECTRIFICAITON AND INSTALLATION OF PREPAID ELECTRIC METER AND AMR AT MIL STN JAISALMER
2020_MES_394273_1
800516/JSLR/2020-21/E8
Open Tender
Electrical and Maintenance Works
Item Rate
365 days
Jaisalmer
Please refer Tender documents.
9 documents required · 9 mandatory
₹3,000
GE (A) Jaisalmer
₹6.7 L
Yes
Jodhpur
12 Feb 2021
10 Nov 2020
22 Jan 2021
10 Nov 2020
20 Jan 2021
6 Jan 2021
22 Nov 2020
Amount
Taking down old existing unsv HT Cable of any size complete all as specified and directed.
Taking down old existing stone patti of any size complete all as specified and directed.
Relaying of Old retrieved HT U/G cable of any type any dia complete all as specified and directed.
Relaying of Old retrived Stone Patti of any type any dia complete all as specified and directed.
Supply, laying & testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty)with stranded aluminium conductor, 11000 volts grade (Earthed), of size 3 core 185 Sqmm complete all as specified and directed.
All as per item No 5 here in before but 150 Sqmm 3 Core.
All as per item No 5 here in before but 120 Sqmm 3 Core.
All as per item No 5 here in before but 95 Sqmm 3 Core.
Supply and fix cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination, heat shrink, joint complete with jointing material and accessories suitable for 3 core 95/120 sqmm cable.
All as per item No 9 here-in-before but size 150/185 Sqmm.
Supply and fix cable jointing kit for 11 KV (Earthed) grade cable for straight through, heat shrink, joint complete with jointing material and accessories suitable for 3 core 95 sqmm cable.
All as per item No 11 here-in-before but size 120 to 185 Sqmm.
Surface excavation not exceeding 15 cm deep and getting out in soft/loose soil complete all as specified and directed by Engineer-In-Charge.
Surface excavation not exceeding 15 cm deep and getting out in hard/dense soil complete all as specified and directed by Engineer-In-Charge.
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation, laying of cable/pipe etc not exceeding 10 sqm on plan and getting out in Soft/disintegrated (any type of soil) complete all as specified & directed by Engineer-in-Charge.
Returning, filling in, including, spreading, levelling, watering and well ramming excavated Soft/disintegrated (any type of soil) in layers all as specified & directed at site.
Removing excavated Soft/Disintegrated (any type of soil) to distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point all as directed by Engineer-in-charge.
M&L for sand cushioning to underground XLPE cable with tibba sand and punning to provide required cover complete all as directed by Engineer-in-charge. (Note :- For the purpose of payment only punned thickness shall be measured).
Supplying and laying Jodhpur stone quarry faced stone slab cover 25 to 30 cm in width, 50 to 60 cm long and 40 to 50 mm thick, laid dry and abutting each other with gap between adjacent slab not exceeding 10 mm over under ground cables for protection complete all as specified & directed by Engineer-in-charge.
Supply, installation, testing and commissioning of 11 KV, 3 Phase, 50 HZ totally enclosed metal clad SF6 type VCB having rupturing capacity up to 800 Amps, RMU, STC 21kA for 01 sec, IAC 21 kA for 1 sec, Copper bus bar, type 2 ways motor operated, outdoor, non-extensible, RL comprising of 01 LBS & 1 VCBs in a single unit (LBS & VCB to be motorised) rated power frequency voltage 28 KV, rated impluse withstand voltage 75 KV, rated current for ring main feeder 630 Amp, rated current for VCB 630A, short time current 21 kA for 3 Sec, rated short making current 50 KV, rated current for ring main feeder -630 Amp, rated current for VCB 630A, short time current (ik)-21KA for 3 sec, rated short making current 50 KV, ambient temperature (-5 degree to +50 degree celsius), designing ambient temprature (40 degree C), with IP 54.
Boring (horizontal) of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine including HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure all as specified and directed.
M&L for bore earthing not less than 250mm dia 16 feet deep filled with black soil upto 7 feet from bottom complete with galvanised iron pipe 40mm bore medium grade 3m long tapers at bottom & provided 12mm holes (staggered) at 75mm centre to centre upto 2.5m of length from bottom, burried directly in ground filled with 45cm alternate layer of magnesium sulphate, charcol & salt up to ground level & connected to galvanised iron strip 32x6mm above ground level as earthing lead by means of bolt and nut, check nuts and washers of galvanised iron or steel including brazing work upto equipment and 40mm dia light grade GI pipe for earth lead protection, earthing chamber, test point terminal complete and testing on completion and including taking out old earthing complete all as specified & directed by Engineer-in-charge.
Supply and Fixing Feeder Piller Box outdoor type single door front openable in two half not less than 1.20Mx1.20Mx1.00M made out of 3.15 mm thick CRCA sheet powder coated supported on angle iron frame 50x50x6MM having legs 1.2 Mtr long grouted in the PCC upto 60CM, aluminium bus bar 03 Nos rated capacity 200A(HT) duly insulated 11000 Volt grade for phases supported on HT porcelain insulator, PCC foundation 1:2:4 and with barberd wire fancing and gate as per approval of GE/Engr-in-Charge to avoid unwanted entry complete all as specified & directed by Engineer-in-Charge
Opening the binding wire from 33 KV over head line pin/disc insulators, J hooks from PCC pole 11 meter for re-stretching the ACSR conductor and earth wire, after re-stretching without kinks & bends, testing of all insulator with suitable rating meggers, binding the existing serviceable/new (If U/S) pin / disc insulator with appropriate size of aluminium binding wire, check the distance between conductor to conductor (should be as per IE rule), if not found suficient than extend the existing cross arms, V-cross with the help of welding, testing the complete approx 7 KM line all as specified & directed by Engineer-in- Charge.
NOTE FOR ITEM NO 24.00:- (i) The above work includes clearing/ prooning of tree branches falling around the conductors. (ii) Cost of binding and jumper wire deemed to be included in the quoted rate, No extra amount will be paid. (iii) Pin/Disc insulators, cross arms etc measured and paid separetly. (iv) Restoration/charging of 33 KV line will be responsibility of the contractor. (v) Any item missed out but technically required for restoration of line is deemed to included in unit quoted rates.
Supply & fix insulator, disc type, porcelain, vitreous,white, brown or green of suitable size socket type, disc assembly for tension clamp for conductor working pressure 33 KV complete all as specified and directed.
Supply & fix insulator, pin type, porcelain, vitreous,white, brown or green of suitable size with clamp for conductor working pressure 33 KV complete all as specified and directed.
Supply & fix BIS (as per IS 13779) certified and IEC 62053-21, IS-12063, IS-11731 complying LT Three phase four wire CT operated static energy meter digital type(ASIC/micro controller) of accuracy class 1.0 with Backlit LCD display of rating -/5 A (measures and displays KWH ,V, Current I, KW, PF , MD in KW) with special features like TOD, optical communication port (RS232/RL-11/RJ-45) complete all as specified and directed.
NOTE FOR ITEM NO 27.00:- (a)The meter shall have provision in such a way that service cable of consumer shall be directly passed through the meter for measurement.Piercing screws shall be used in the meter for connection. The meter shall be suitable to accommodate aluminium cable of existing size at ground. Otherwise alternate arrangement to be done for terminals/terminal blocks to be done by the contractor without any extra cost to the department. (b) Proper sealing arrangement shall be provided on the meter to make it temper proof. All the seal shall be provided on front side only. (c) One HHU/MRI to be provided free of cost for taking reading of the meters. (d) The terminal block shall be made from high quality non-hygroscopic, fire retardant, reinforced polycarbonate/non bakelite material which shall form an extension of the meter case along with terminal cover made out of same material if required. The terminal cover shall be transparent.
Supply and fix ISI marked/IS 2705 (part I to IV) complying cast resin LT Current transformer 5VA rated burden at 0.8 PF lag ,square/Ring type of Capacity 500/5 Amp (basic insulation level:3KV rms) complete with suitable size/core of wire,mounting arrangement (base plate with legs) with testing/connecting of meters etc all as specified and directed. Note:- Type Test reports as per IS 2705 from NABL accredited laboratories shall be submitted.
Supply and fix ISI marked/IS 2705(part I to IV) complying cast resin LT Current transformer 5VA rated burden at 0.8 PF lag ,square/Ring type of Capacity 300/5 Amp(basic insulation level:3KV rms) complete with suitable size/core of wire,mounting arrangement(base plate with legs) with testing/connecting of meters etc all as specified and directed. Note: Type Test reports as per IS 2705 from NABL accredited laboratories to be submitted
Supply and fix ISI marked/IS 2705(part I to IV) complying cast resin LT Current transformer 5VA rated burden at 0.8 PF lag ,square/Ring type of Capacity 200/5 Amp(basic insulation level:3KV rms) complete with suitable size/core of wire,mounting arrangement(base plate with legs) with testing/connecting of meters etc all as specified and directed. Note: Type Test reports as per IS 2705 from NABL accredited laboratories to be submitted.
S&F 35 Sqmm HRFR PVC insulated industrial copper cable single core unsheathed flexible cable 1100 Volt confirming to IS 694 complete with copper lugs and connecting to terminal block complete all as specified and directed by Engr-In-Charge.
S&F 50 Sqmm HRFR PVC insulated industrial copper cable single core unsheathed flexible cable 1100 Volt confirming to IS 694 complete with copper lugs and connecting to terminal block complete all as specified and directed by Engr-In-Charge.
Supply, installation, commissioning and testing of IP55 complying LT Meter box, made of MS sheet minimum 2mm , out door type Clamp/stand mounted single door side opening with locking arrangement, with toughened/triplex glass with suitable frame on centre for view of reading without opening the gate , factory assembled canopy on top/roof tatapering down, 7tank process powder coated, Earthing bolt 25X8mm fitted with box from inside and complete with proper clearance on all sides & to accommodate Meters with required size of terminals(LT) duly insulated including cutting the existing cable and lugging including fixing on pole/ground with the help angle iron frame of suitable size, clamps,nuts,bolts washers etc completely sealed, jointing to existing earthing with the help of 4 Sqmm copper cable from existing earthing to meter box, lugs etc all as directed.
M & L for submain wiring as per colour code (Red,black & green for three phase) circuit with four single core PVC insulated cable with multistranded copper conductor of nominal cross sectional area of 2.5 Sqmm Sqmm (FRLS) in PVC Conduit/Flexible conduit one run of PVC insulated multistranded copper conductor nominal cross sectinal area of 2.5 Sqmm (FRLS) of continous earth wire green in colour complete all as specified and directed by Engr-In-Charge. (Note:- Four runs of 2.5 Sqmm cable & one run of 2.5 Sqmm cable one run of PVC Conduit/Flexible conduit shall be paid as one unit length).
M & L for cross arms, bracing supports, clamps and back plates fabricated from structural steel section including nut, bolt, washers welding, bending cold or hot, drilling holes for bolt in any shape or size as indicated or directed and inclusive of one primer coat one under coat and one finishing coat of aluminium paint.
M&L for danger notice plate of 1.6 mm thick mild steel sheet , vitreous enamelled white, with letters , figures and conventional skull and bones in signal red colour and fixed with M S clamps , bolts and nuts of approved size ,for HT 33 KV, 25x 20 mm size complete all as directed by Engineer-in-Charge.
M&L for danger notice plate of 1.6 mm thick mild steel sheet , vitreous enamelled white, with letters , figures and conventional skull and bones in signal red colour and fixed with M S clamps , bolts and nuts of approved size ,for HT 11 KV, 25x 20 mm size complete all as directed by Engineer-in-Charge.
S&F GI tubing “light grade” of 100mm dia in trenches/ on pole for protection of cables complete all as specified & directed by Engineer-in-charge.
Supply, and fixing 11 KV HT cable route indicator/marker made of MS plate 15cm dia and 10mm thick and 60 cm long, 45cm grouted in the PCC and 15 cm above th GL of MS angle of 50 x 50 x 6mm with the logo at the centre "HT CABLE GE (A) JSLR" complete with PCC as required qty all as specified and directed
Taking down energy meter fixed in panels of any capacity/any type after carefully disconnecting electrical connections all as specified and as directed by Engr-in-Charge. Note:- Quoted rate shall deemed to be inclusive of following parameters:- (a) Meter reading record shall be submitted before and after replacement duly signed by the contractor rep and MES rep. (b) Old meters should be handed over to MES store. (c) Any rejoining of wires /cables shall be done using suitable ferrule /cable connectors after removal of meter. (d) The cost of making good disturbed surfaces & matching to the existing surface is deemed to be included in the unit quoted rates.
Supply, install, testing & commissioning of Microprocessor based single phase tamper proof electronic prepaid energy meter with provision of conversion into post paid at the time of emergency,surface mount type and of rating 240 Volts, 50 HZ, of range 10-60 Amps, confirming to IS 16444 & IS 15884 with LED display and parameters like Voltage, Current, Frequency, Power, Powerfactor,KWh/KVA, default inbuilt single source,suitable range RF Communication suitable for outdoor suitable Range data accumulator and also compatible for Prepaid online energy monitoring / billing system, through remote software / data export to ERP complete all as specified and as directed by Engr-in-Charge.
Supply, install, testing & commissioning of Microprocessor based Three phase tamper proof electronic prepaid energy meter with provision of conversion into post paid at the time of emergency ,surface mount type and of rating 415 Volts, 50 HZ, of range 10-60 Amps, confirming to IS16444 & IS15884 with LED display and parameters like Voltage, Current, Frequency, Power, Powerfactor,KWh/KVA,default in built single source, suitable long range RF Communication suitable for outdoor suitable Range data accumulator and also compatible for Prepaid online energy monitoring / billing system, through remote software / data export to ERP complete all as specified and as directed by Engr-in-Charge.
Note for item No 41.00 & 42.00:- Payment for fully functional meters only with complete prepayment system will be made to the contractor/bidder.The complete work of installation, testing, commissioning & software linking should be as per the requirement of GE/Engr-in-Charge to be got executed by the OEM/Authorized representative of OEM.
Supply, install, commissioning & testing of Outdoor suitable Range accumulate Protocal and the data transfer to the existing installed Software complete all as specified and as directed by Engr-in-Charge. Note:- (a)The cost of pole /fixing /mounting arrangement on which the accumulator to be installed and SMPS power supply is deemed to be included in the unit quoted rates. (b) Above referred date accumulator/DCUS/Gate ways must have internal memory to store data of minimum 300 single/three phase RF meters data should have inbuilt battery backup of minimum six hours.
Supply and Installation of Network Server, MQTT based intelligent network server for bridging between gateway and end application. Eliminate duplicate packets, schedule acknowledgement, and adapts data rates
Supplying, Fixing, Commissioning and testing of configuration of server Hosted multi user web based software with following modules: (i) Meter Data Management Module: The meter data management module would be responsible for collecting the data from the data concentrator and make the data available to the billing system. The system would support offline meter data entry. The meter data management system would capture and provide the follwing data:
(a) 30min instantaneous data from all the meters for seven parameters- Cumulative Energy,Power, Current, Voltage, Power factor and Frequency. (b) Monthly and quarterly billing survey data for cumulative energy and max demand (ii) Billing Module: The billing module would collect the data from the meter data management module, calculate billing determinant and make energy data/ billing data available to admin and end users. (iii) Occupation and vacation Module: The System would support occupation/ vacation based on the unit categories. The system would support automatic data capture on occupation and vacation events. (iv) Customer portal: The system would include a customer portal for the resident/ occupant to log in and view their own energy / billing data. (v) Energy Accounting Module: The system would include features of energy accounting. the system would be able to account for total energy block wise, facility wise and would also allow calculations of unaccounted energy in case total energy meter is also available. (vi) Communication module: The system should provide conmmunication of energy data and bills via print, email and sms methods (vii) Meter Master Data : The system would support meter data repository. The system should support meter replacment process. (viii) Excel Export : The system would support export of metering and billing data in excel format Make : Elmeasure,L&T ,Secure ,HPL
NOTE FOR ITEM NO 45.00:- (a) Bidder/OEM shall make arrangement (available a stand by on site) for disaster management server make available a standby at site (secondary server) in case of breakdown of parent server without any extra cost to the department for complete period of 10 years. (b) Bidder/OEM will arrange static IP and will provide internet infrastructure at GE/BSO office for servers having minimum speed of 10-20 MBPS without any extra cost to the department for the period of 10 years. (c) Contractor will be fully responsible for server connectivity and also functioning of complete system comprising of server for data base, App, web, standby data base, monitoring/management including desktop for monitoring/manangement primary and secondary firewall, switch duly installed and suitable size computer table, Chair and racks as per requirement.No extra paymet will be provided for the infrastructure.
M&L for Hosting, GPRS charges for 10 years warranty from the date of completion. Note: Bidder /OEM will provide necessary sim card/infrastructure for communication and will maintain recurring charges for 10 years.
S & F desktop computer with the following specifications complete all as specified and directed by Engr-in-Charge :- Software Parameters:- (a)8GB RAM, DDR4 RAM with Genuine Windows 10 Operating system or higher version (b) Intel Processer with 8th Gen core i5 processor with min speed of 2.3GHz (c) Hardware storage of min 1TB Hardware Parameters:- (a) Screen size of min 19.5 inches of black in color with full HD display (1920 x 1080), LED antiglare backlit display (b) Minimum of 3 USB ports. (c) With optical drive of tray load DVD Drive. (d) With one Qwerty keyboard & wireless mouse. Make : Dell, Model No : Optiplex 5060MT commercially equivalent in HP/Apple.
Supply and installation of Dell power edge T440 or equivelent servers with the following specifications:-
Cont… - Intel Xeon bronze 3106, 8C/8T, 9.6GT/s, 11M cache No TurboNo HT (85W) DDR4-2133 - Chassis with upto 16, 2.5" hot plug hard drivers, Tower confrguration - 2666MT/s RDIMMs - iDRAC9, Enterprises - 2 1TB 7.2K RPM SATA 6 Gbps 512n 2.5in Hot-plug hard drive - PERC H730P+Raid controller, 2 GB NV cache, Adapter, Full height. - Standard heat sink for less = 150W - DVD +/- RW, SATA, Internal - Dual, Hot-Plug, Redundant power supply (1+1), 1100W - Jumper cord, 10A, 4MC13/C14 (india BIS) - Deskside power cord, G type, 230V, 2M (Nepal, Shri Lanka, India) - Trusted platform module 2.0 - Duel-port 1Gb E on board L OM - Casters, T440 - Raid 1 - Performance BIOS setting Make: - Dell, IBM, HP - Complete all other associated accessories for satisfactory performance. Note:- The setup shall include ten years on site administration support post DLP. The OEM shall install licensed windows 10 and above with anti virus duly approved by GE.
S & F Inverter along with tubular batteries having following specifications complete all as specified and directed by Engr-in-Charge:- (a) Capacity of 2KVA of inverter 1680 W, sine wave output. (b) Battery of 12 Volts, 150Ah tubular plates technology-2 Nos (c) High durability with sealed plastic housing (d) Comprehensive protection against short-circuit, reverse polarity, battery over charge, deep discharge etc. (e) Battery warranty of atleast 60 months (f) Intuitive display to easily understand staus of mains availability, battery status, etc. Make :Luminous , Model No : Cruze 2KVA, Battery-ILTT 18048N 150AH or techno-commercially equivalent in Livguard/Microtek
S & F laser jet printer with single function black & white with USB connection with printing speed of min 40 pages per minute with 512MB RAM complete all as specified and directed by Engr-in-Charge. Make :Kyocera kyom 2040Dn 1102S32Us0 equivalent in Canon /Epson. Note:- Bidder/OEM should maintain the stationery and cartridges for printer throughout the warranty period without any extra cost to the department. Note:- (a) Any item missed in the specification of prepaid metering system above (item 40.00 to 49.00) but technically required for satisfactory working of the prepaid metering system is deemed to be included in the unit quoted rates. (b) OEM/Bidder will be responsible for manning (by employing 01X Trained skilled IT personel and 01 x trained semi skilled personal in shift 9 AM to 5 PM (Except on sunday & holidays) complete prepaid metering system for two years from the date of completion without any extra cost to the department. However, OEM/Bidder will have to address any complaints received in odd hours 24x7 till completion of Phase III. Contractor/OEM will be responsible for arraging his own means of transport for installation and fault rectification through out the phase I, phase II and phase III fo the contract, No transportation will be provided by the department.
M & L for submain wiring as per colour code(Red,black & green for single phase) circuit with two single core PVC insulated cable with multistranded copper conductor of nominal cross sectional area of 4.00 Sqmm (FRLS) in PVC Conduit/Flexible conduit one run of PVC insulated multistranded copper conductor nominal cross sectinal area of 4.00 Sqmm (FRLS) of continuous earth wire green in colour complete all as specified and directed by Engr-In-Charge. (Note:- Two runsof 4.00 Sqmm cable & one run of 4.00 Sqmm cable one run of PVC Conduit/Flexible conduit shall be paid as one unit length.
All as per item No 51 here-in-before but 4 x 6 Sqmm cable and 2 x 6 sqmm Sqmm copper cable (Note:- Four runs of 6.00 Sqmm cable & two run of 6.00 Sqmm cable one run of PVC Conduit/Flexible conduit shall be paid as one unit length).
S & F for MCB DB TPN 4 way with provision for MCB TPN as incommer and SP&TP MCBs as out going double door IP 43 complete prewired including Bus Bar etc suitable for operation on 415 volt 50 Hz AC supply including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and as directed .
S & F for MCB four pole rated capacity 63 Amps, 415 volts breaking capacity 10 KA complete all as specified and as directed.
S & F for MCB Single pole rated capacity 6 to 32 amps, 240 V breaking capacity 10 KA complete all as specified and as directed.
Outsourcing of services for operation, manning and operation maintenance to pre-paid meters at military station Jaisalmer and all related equipments as mentioned below including the keeping equipments in healthy condition by employing 01X Trained skilled IT personel and 01 x trained semi skilled personal in shift 9 AM to 5 PM (Except on sunday & holidays) having knowledge of operation of prepaid meter including carrying out all daily maintenance and reports all as directed by GE/Engineer-in-charge and as per Indian electricity rule / engineering practices & maintaining properly the protective instruments complete in good condition and all maintenance records, break down records, by providing with adequate details comprising of following items & equipments and comprising the pre-paid meters at military station Jaisalmer all as specified to the entire satisfaction of GE/Engr-In-Charge.
(Manning & operation will be applicable after two years of defect liability period (DLP) from the date of completion of work) (a) Single phase prepaid meters . (b) Three phase prepaid meters. (c) Bulk Meters (c) Network server and data management connectivity (d) Server Computer and UPS Installed at BSO/GE (Army) Jaisalmer (e) Printer and associate Items. (f) GPRS/Internet connection with static IP/Gateway Charges/any other charges related to prepaid metering system complete period of M&O to be borne by contractor/Bidder Note : All type of repairs/maint including materials such as Ink, paper, cartidage, wire, arrangement of vehicles etc to be provided by the contractor without any extra cost to the department for five years. Note:- (i) MOU will be made between OEM & Contractor /Bidder and department copy of which to be made available with uploaded tender documents. (ii) Bidder will be responsible for hosting. GPRS charges of data accumulators and providing internet for server with minimum speed of 10-20 Mbps without any extra cost to the department for entire duration of outsourcing of services for M & O of prepaid meter system.
M & L for fabrication, installation and connection of LED display board showing HT (33 & 11 KV) over head line and UG cables throughout spreaded in Jaisalmer Mil Cantt in different colour code made out of 20mm thick pre laminated/acrylic sheet with boxed in suitable size of aluminium box structure complete of size minimum 3.5 mtrx3.5Mtr or above alongwith fixing hooks, LED connection and with complete layout diagram, legends etc which is to be commected from Engr-in-charge all as specified and directed.
SANJEEV ENTERPRISES
ACE PROMOTERS
Leo Air and Power Solution pvt Ltd.
M/s Prem Associates
WELTRONENGINEERINGSERVICES
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .