| 1 | L1₹11.7 LAccepted-AOC | L1 | Accepted-AOC Quoted lowest rate | |
| 2 | L2₹12.4 L+₹12,449 (1.02%)Rejected-Finance | L2 | Rejected-Finance Quoted other than lowest rate | |
| 3 | L3₹13.2 L+₹99,390 (8.13%)Rejected-Finance | L3 | Rejected-Finance Quoted other than lowest rate | |
| 4 | L4₹13.6 L+₹1.4 L (11.4%)Rejected-Finance H NO 18 SHEET NO 5 A KATIA COLONY NAMDEV MARG BATHINDA 151001 PB | BATHINDA | BATHINDA | PUNJAB | 151001 | L4 | Rejected-Finance Quoted other than lowest rate | |
| 5 | L5₹13.8 L+₹1.5 L (12.5%)Rejected-Finance 64 SHAHEED UDHAM SINGH MARKET NEAR OLD BUS STAND BATHINDA 151001 PB | BATHINDA | BATHINDA | PUNJAB | 151001 | L5 | Rejected-Finance Quoted other than lowest rate |
Tender Value
Refer Docs
EMD Value
₹50,000
Closing Date
6 Nov 2020, 6:00 pmClosed
Shri Sachin H Chavan IDSE
GE North Bathinda Mil Stn
REPAIRS TO SUNKEN FLOOR, PLUMBING, SANITARY WORK AND TANK CLEANING WORK IN MD ACCN OF HIMGIRI ENCLAVE AND BIBIWALA COLONY UNDER AGE B/R V OF GE NORTH BATHINDA AT BATHINDA MIL STN
2020_MES_387254_1
8935/NIT-30/20-21
Open Tender
Civil Works - Water Works
Item Rate
244 days
Bathinda Mil Stn
Class E
9 documents required · 9 mandatory
₹500
GE(N) Bathinda
₹50,000
Yes
26 Nov 2020
17 Oct 2020
9 Nov 2020
17 Oct 2020
6 Nov 2020
31 Oct 2020
17 Oct 2020 - 23 Oct 2020
Amount
Demolition of cement concrete (unreinforced) in WC floor area (tile and sub base) not exceeding 5cm thickness of any description and in any position including removing rubbish material from building and thrown in low lying empty area (as per direcction of AGE/JE) at any distance upto 500 metres from the site complete all as specified and as directed by Engr-in-Charge
Demolition and Digging out sunken floor filling including taking out unserviceable WC and removing rubbish material from building and thrown in low lying empty area (as per direcction of AGE/JE) at any distance upto 500 metres from the site, complete all as specified and as directed by Engineer-in- charge.
Material and labour for sunken treatment to sunken floor, cleaning the surface by wire brush, rendering to floor and sides with 10mm thick in cement mortar (1:4) including mixing of liquid WPC in cement mortar @ 200ml per bag of cement of 50kg, finished even and smooth without using extra cement, after that material and labour Providing for applying two coats of two component (1 part Liquid: 2 part Powder) ready to use cementitious waterproof coating on properly prepared surface by brush having elongation of >50% for the applying water proofing treatment, immediately after 1st coat laying glasses fiber mess of 2x2mm as per following steps on horizontal and verticle surfaces of sunken floor complete all as per manufacture instructions and as directed by the Engineer-in-Charge. (i) Applying 1st coat of two components modified polymer coating . (ii) Provn of glasses fiber mess of 2x2mm immediately on alone coating. (iii) Applying 2nd coat of two components modified polymer coating after 72hrs on horizontal and verticle surfaces. Make : Dr Fixit/Fosroc/BASF/STP NOTE:- (i) Complete treatment to be carried out by authorised applicator. (ii) Before, as work proceed and after completion of each process of treatment take colour photograph and keep in safe custody of Engineer-in-Charge. (iii) Liquid WPC for mixing in CM shall be measured & paid separately as Supply only
Material & Labour for PCC (1:7:12) type F2 using 40mm graded stone aggregate as loose filling of sunken floors complete all as specified and as directed by Engineer-in-charge.
Material and labour for 30mm thick cement concrete (1:2:4), type B-0 using 12.5 mm graded stone aggregate as in sub base of floor for leveling course, surface finished rough to recieved tile/PCC floor work, including mixing of liquid WPC in mortar @ 200ml per bag of cement of 50kg, complete all as specified and as directed by the Engineer-in-Charge. (Note :- (i) WPC shall be measured & paid separately as Supply only. (ii) Tile/Kota stone/PCC floor work etc shall be measured and paid separately under appropriate item of this schedule.
Demolition of cement concrete (unreinforced) in first floor, ground floor and paving not exceeding 15cm thickness below or above ground level of any description and in any position including removing rubbish material from the site to a distance not exceeding 100 metre and deposited as directed complete all as directed by Engr-in-Charge
Material and labour for 50 mm thick PCC (1:3:6) type C-2 using 40mm graded stone aggregate as in flooring, hard standing, plinth protection/path etc. finished even and smooth without using extra cement complete all as specified and as directed by the Engineer-in-Charge.
Demolition of floor hearth or wall tilling including cement mortar bedding but not backing including removing rubbish material from the site to a distance not exceeding 100 metre and deposited as directed complete all as directed by Engr-in-Charge
Material and labour for Glazed ceramic coloured tiles of size 350mmx 250mm / 450mmX 350mm, 7mm thick, as in vertical surface set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile including necessary cutting as per site requirement, tiles laid over and including 10 mm thick (Av thickness) bedding layer (rendering) in cement mortar (1:4) complete all as specified and as directed by Engineer-in-Charge.
Material and labour for Non Skid ceramic coloured tiles 7 to 8 mm thick square or rectangular area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, as in floor set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile including necessary cutting as per site requirement, tiles laid over and including 15 mm thick bedding layer (screed) in cement mortar (1:6) complete all as specified and directed by Engineer-in-Charge.
Material and labour for vitrified ceramic coloured tiles (light shade) 10 mm thick square or rectangular area of each tile not exceeding 0.36 sqm, as in floor, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile including necessary cutting as per site requirement, tiles laid over and including 15 mm thick bedding layer (screed) in cement mortar (1:6) complete all as specified and directed by Engineer-in-Charge.
Material and labour for vitrified ceramic coloured tiles (light shade) 10mm thick square or rectangular (same as floor tile, as per above item ), as in skirting, dado etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile including necessary cutting as per site requirement, tiles laid over and including 10 mm thick bedding layer (screed) in cement mortar (1:4) complete all as specified and directed by Engineer-in-Charge.
Demolition of brick work or stone / boulder masonry, built in cement mortar or cement lime mortar in any description including cleaning and stacking serviceable brick for re use and balance removing rubbish from the site complete all as specified and as directed by Engineer-in-charge.
Material and labour for brick work with sub class ‘B’ old size burnt clay bricks, straight or curved on plan exc. 6 metre mean radius built in cement mortar (1:6) complete all as specified and as directed by Engineer-in-charge.
Material and labour for brick work with sub class ‘B’ old size bricks (old serviceable bricks obtained from demolition/dismantled item shall be reused ) straight or curved on plan exc. 6 metre mean radius built in cement mortar (1:6) complete all as specified and as directed by Engineer-in-charge.
Material and labour for rendering/plastering 15mm thick in cement mortar (1:4) on any face of Brick walls or concrete surfaces (external surface), including mixing of liquid WPC in mortar @ 200ml per bag of cement of 50kg, finished even and smooth without using extra cement complete all as specified and as directed by the Engineer-in-Charge. (Note :- Water proofing compound shall be measured & paid separately as Supply only)
Material and labour for rendering/plastering appx 15mm thick (matching with existing plaster thickness) in cement mortar (1:6) on old brick or concrete surfaces of walls/pillars /cornices in patches matching with existing, finished even and smooth without using extra cement including old rusted plaster taking down, raking out joints, hacking for key and scrubbing down with water complete all as specified and as directed by the Engineer-in-Charge.
Supply only liquid water proofing compound complete all as specified and as directed by the Engineer-in-Charge. Make : Dr Fixit/Fosroc/BASF/STP
Supply & fixing in replacement vitreous china wash down water closet pan (pedestal pattern, EWC) white clour (excluding flushing cistern and flush pipe) including connection to drain etc., including plastic water closet seat with cover (white clour) closed pattern with flat bottom and mild steel chromium plated or aluminised hinging device including stainless steel chromium plated jet spray with 01 mtr long PVC pipe with CP connector and necessary nut bolts and with necessary CP screws and plug for fixing WC complete all as specified and as directed by Engineer-in- charge.
Supply & fixing in replacement plastic water closet seat with cover (white colour) closed pattern with flat bottom/recessed bottom and mild steel chromium plated or aluminised hinging device complete all as specified and as directed by Engineer-in- charge.
Supply and fixing in replacement CP jet spray, including pipe 1 mtr long with CP connecctor, fixing in WC and to angle valve for water connection complete, all as specified and as directed by Engineer-in-charge.
Supply and fixing hand shower (health faucet) ABS body including 1 meter long 8mm dia flexible tube and including wall hook including taking down old any type shower complete all as specified and as directed by Engineer-in-charge. Make :- Cat Part ALD-CHR-593N of Jaquar or equivalent (Equivalency approved by GE) in make mentioned in Appx A to PSS-II
Supply and fixing in replacement 10 litres capacity PVC valveless syphonic action type low level flushing cistern (white colour) with inlet, ball valve, float, handle including fixing/hanging accessories and 32mm dia PVC flush pipe, PVC Connection 450 mm long with PTMT nuts suitable for 15mm bore pipe complete all as specified and directed by Engineer-in-Charge.
Supply & fixing in replacement 32mm bore Brass chromium plated bottle traps for wash basins with inlet and outlet screwed for pipe or connections including necessary packing, union and union and cleaning cap and fixed complete all as specified and as directed by Engineer-in-Charge.
Supply & fixing in replacement 32mm bore Waste fittings/Waste coupling, brass, chromium plated for sinks, basins, etc. with long screwed shanks and fly-nuts, flange end bedded in red lead cement and other end fixed complete all as specified and as directed by Engineer-in-Charge.
Supply & fixing in replacement 40mm bore Waste fittings/Waste coupling, brass, chromium plated for sinks, basins, etc. with long screwed shanks and fly-nuts, flange end bedded in red lead cement and other end fixed complete all as specified and as directed by Engineer-in-Charge.
Supply & fixing in replacement spring type PVC waste pipe not less than 700mm longh suitable for 32mm bore waste coupling of sinks, basins, etc. complete all as specified and as directed by Engineer-in-Charge.
Supply & fixing in replacement spring type PVC waste pipe not less than 700mm longh suitable for 40mm bore waste coupling of sinks, basins, etc. complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing in replacement PVC Bathroom mirror cabinet of appx size 432mm X 311mm X 140mm (Compact Mirror Cabinet, Concealed shelves) complete all as specified and as directed by Engineer-in-charge. Make:- Prayag / Commander/Wintex or equivalent (Equivalency approved by GE) approved make from list of make attached in tender documents.
Supply & fixing in replacement vitreous china wash basin, white, flat back of size 550mm x 400mm, including 32mm chromium plated waste coupling and PVC waste pipe including bracket and cutting for and pinning in end of bracket or erecting including fixing only pillar tap (new or serviceable old pillar tap as per site condition ) complete all as specified and as directed by Engineer-in-Charge. (Note :- Pillar tap if required in replacement, shall be measured & paid separately as Supply only under appropriate item of BOQ.)
Supply only pillar tap cast copper alloy with capstan head, chromium plated, fancy type, high pressure with or without letter 'Hot' or 'Cold' with long shank and fly nuts screwed for iron pipe or for brass ferrule 15mm bore complete, all as specified & directed by Engineer-in-charge. Note :- The minimum weight of tap shall be as given in SSR or in relevant IS
Supply & fixing in replacement stainless steel sink made out of 1.00mm thick sheet, overall size 495mm x 420mm with bowl size 410mm x 330mm x 160mm, kitchen or laboratory with plugs, washers, waste pipe including bedding in cement mortar, fixing in existing space or fixing with cast iron cantilever brackets and connecting union to waste pipe, including taking down old unserviceable sink complete all as specified and directed by Engineer-in-Charge.
Supply & fixing in replacement HDPE Lid (cover) for PVC water tank of capacity upto 1000 Ltr complete all as specified and as directed by Engineer-in-charge.
Cleaning and removing all scale and dirt, etc, from existing serviceable PVC tanks (OHT) of capacity upto 500 litrs without disconnecting or lowering, taking out mud from tank after proper drain out the water (manualy or mechanically ) including from mouths of circulating pipes etc. after cleaning checking all inlet and out let connections and tightening the same as required, Lid of tank refix properly complete all as specified and as directed by Engineer-in-charge.
Cleaning and removing all scale and dirt, etc, from existing serviceable PVC tanks (OHT) of capacity exceeding 500 litre but not exceeding 1000ltrs, without disconnecting or lowering, taking out mud from tank after proper drain out the water (manualy or mechanically ) including from mouths of circulating pipes etc. after cleaning checking all inlet and out let connections and tightening the same as required, Lid of tank refix properly complete all as specified and as directed by Engineer-in-charge.
Disconnecting existing serviceable PVC tanks (OHT) of any capacity upto 1000 litre, and keep in safe custudy. After repair of tank stage re-fixing the water tank in original position including all making inlet and outlet water connection (as per existing) and Lid of tank refix properly complete all as specified and as directed by Engineer-in-charge. Note :- Removing all scale and dirt from tanks and from mouths of circulating pipes upto entire satisfacation of Engineer-in-charge/JE before refixing the water tank in original position, and cost of same shall be included in the unit rate nothing shall be paid extra on this account.
Supply & fixing rotational moulded polyethylene water storage tank white colour of capacity 500 litres (cylindrical vertical, triple layered with closed top), hoisted and fixed in position including making inlet and out let connection and fixing ball valve and gate valve including dismantling/taking down of existing unserviceable PVC water storage tanks of any description complete all as specified and as directed by Engineer-in-charge. (Note :- Float valve and gate valve shall be measured & paid separately as Supply only under appropriate item of BOQ.)
Supply & fixing rotational moulded polyethylene water storage tank white colour of capacity 1000 litres (cylindrical vertical, triple layered with closed top), hoisted and fixed in position including making inlet and out let connection and fixing ball valve and gate valve including dismantling/taking down of existing unserviceable PVC water storage tanks of any description complete all as specified and as directed by Engineer-in-charge. (Note :- Float valve and gate valve shall be measured & paid separately as Supply only under appropriate item of BOQ.)
Taking up or down existing galvanised steel water tubing (GI pipe) 15mm bore including fitting/connection from wall/ceiling/floor/concealed etc. including removing from site/keeping aside for reuse (serviceable as good condition as directed) complete all as specified and as directed by Engineer-in-charge.
Taking up or down existing galvanised steel water tubing (GI pipe) 20mm bore including fitting/connection from wall/ceiling/floor/concealed etc. including removing from site/keeping aside for reuse (serviceable as good condition as directed) complete all as specified and as directed by Engineer-in-charge.
Re-fixing old serviceable 15mm bore galvanised steel water tubing (GI pipe) including all fittings like elbow, tee, union, socket, reducer etc. in new or old portion/position to walls, ceiling and laid in floor/concealed in walls etc and making good disturbed surfaces of walls complete all as specified and as directed by Engineer-in-charge. (Note :- Old serviceable pipe and fittings obtained from taking up or down (here-in-before) item of this BOQ shall be reused after necessary cleaning internally.
Re-fixing old serviceable 20mm bore galvanised steel water tubing (GI pipe) including all fittings like elbow, tee, union, socket, reducer etc. in new or old portion/position to walls, ceiling and laid in floor/concealed in walls etc and making good disturbed surfaces of walls complete all as specified and as directed by Engineer-in-charge. (Note :- Old serviceable pipe and fittings obtained from taking up or down (here-in-before) item of this BOQ shall be reused after necessary cleaning internally.
Supply and fixing galvanized steel tubing (GI pipe) medium grade 15mm bore ISI marked with all new fittings like elbow, tee, union, socket, reducer etc. and fixed complete to walls, ceiling and laid in floor or concealed in walls including cutting chases in wall (as required) and making good disturbed surfaces of walls including cutting and threading of existing pipe any dia for insertaion of tee branch including hole in wall to pass the pipe out side for connection as per site requirment complete all as specified and as directed by Engineer-in- charge.
Supply and fixing galvanized steel tubing (GI pipe) medium grade 20mm bore ISI marked with all new fittings like elbow, tee, union, socket, reducer etc. and fixed complete to walls, ceiling and laid in floor or concealed in walls including cutting chases in wall (as required) and making good disturbed surfaces of walls including cutting and threading of existing pipe any dia for insertaion of tee branch including hole in wall to pass the pipe out side for connection as per site requirment complete all as specified and as directed by Engineer-in- charge.
Supply & fixing in replacement 450 mm long PVC connection 15mm size with PTMT nuts complete all as specified and as directed by Engineer-in-charge.
Supply and fixing in replacement corner Glass shelf with bracket, fixed on wall with chromium plated brass screws and PVC plug including taking down old any type shelf complete all as specified and as directed by Engineer-in-charge. Make :- Cat Part ACN-1173 of Jaquar or equivalent (Equivalency approved by GE) in make mentioned in Appx A to PSS-II
Supply and fixing in replacement brass bib tap, with crutch or butterfly handle with capstan head, screwed down, screwed for iron pipe or for brass ferrule 15mm bore complete all as specified & directed by Engineer-in-charge. Note :- The minimum weight shall be as given in SSR or in relevant IS.
Supply and fixing in replacement bib tap cast copper alloy, chromium plated fancy type, long body with crutch or butterfly handle with capstan head, screwed down, screwed for iron pipe or for brass ferrule 15mm bore complete all as specified & directed by Engineer-in-charge. Note :- The minimum weight shall be as given in SSR or in relevant IS.
Supply and fixing in replacement stop valve/angle valve cast copper alloy, screwed down high pressure with crutch or butterfly handle, screwed one end or both ends suitable for 15mm bore iron pipe complete, all as specified & directed by Engineer-in-charge. Note :- The minimum weight of stop valve/stop cock/angle valve shall be as given in SSR or in relevant IS.
Supply and fixing in replacement stop valve/angle valve cast copper alloy, chromium plated fancy type screwed down high pressure with crutch or butterfly handle, screwed one end or both ends suitable for 15mm bore iron pipe complete, all as specified & directed by Engineer-in-charge. Note :- The minimum weight of stop valve/stop cock/angle valve shall be as given in SSR or in relevant IS.
Supply and fixing in replacement two way angle valve cast copper alloy, chromium plated fancy type screwed down high pressure with handle, screwed ends suitable for 15mm bore iron pipe complete, all as specified & directed by Engineer-in-charge. Note :- The minimum weight of valve shall be as given in SSR or in relevant IS.
Supply & fixing in replacement Maze hand shower round/square shape single flow (Face plate stainless steel and ABS Body in chrome finish ) with rubit cleaning system including wall hook complete, all as specified and as directed by Engineer-in-charge.
Supply & fixing in replacement brass cromium plated shower rose 125mm size, with or without swivel joints, any size, including fixing to steel pipe or union complete all as specified and as directed by Engineer-in-charge.
Supply & fixing in replacement pillar tap cast copper alloy with capstan head, chromium plated, high pressure with or without letter 'Hot' or 'Cold' with long shank and fly nuts screwed for iron pipe or for brass ferrule 15mm bore complete, all as specified & directed by Engineer-in-charge. Note :- The minimum weight of tap shall be as given in SSR or in relevant IS
Supply & fixing in replacement pillar tap cast copper alloy with capstan head, chromium plated, fancy type, high pressure with or without letter 'Hot' or 'Cold' with long shank and fly nuts screwed for iron pipe or for brass ferrule 15mm bore complete, all as specified & directed by Engineer-in-charge. Note :- The minimum weight of tap shall be as given in SSR or in relevant IS
Supply and fixing in replacement mixer valve 15mm bore, brass (cast copper alloy) chromium plated, mixer for mixing hot & cold water, suitable for any type of WHB or fixed to wall or fixed on counter, screwed down for iron pipe 15mm bore complete all as specified and as directed by Engineer-in-charge. Note :- The minimum weight of mixer valve shall be as given in SSR or in relevant IS.
Supply only ball brass valves, high pressure with brass rod and high density plastic ball (polythene float) complete, screwed suitable for 20mm bore iron pipe complete all specified and as directed by Engineer-in-charge. Note :- The minimum weight of ball valve shall be as given in SSR or in relevant IS.
Supply and fixing in replacement ball brass valves, high pressure with brass rod and high density plastic ball (polythene float) complete, screwed suitable for 20mm bore iron pipe complete all specified and as directed by Engineer-in-charge. Note :- The minimum weight of ball valve shall be as given in SSR or in relevant IS.
Supply and fixing in replacement gun metal, globe or gate valve (ISI marked), with iron wheel head, screwed both ends suitable for 15mm bore iron pipes complete all as specified and as directed by Engineer-in-charge. Note :- The minimum weight of gate valve shall be as given in SSR or in relevant IS.
Supply and fixing in replacement gun metal, globe or gate valve (ISI marked), with iron wheel head, screwed both ends suitable for 20mm bore iron pipes complete all as specified and as directed by Engineer-in-charge. Note :- The minimum weight of gate valve shall be as given in SSR or in relevant IS.
Supply & fixing in replacement brass chromium plated tubular towel rail 20mm dia 'D' type, 600mm long between flanges fixed to plug , brass CP bracket with screws complete all as specified and as directed by Engineer-in-Charge.
Material & Labour for 100 mm bore cast iron soil waste and vent pipe (sand cast pipe ) in any length with or without ears, fixed to wall with stack clamps (interval of 1m) made out of FI 50x5mm and 16mm dia round iron stay and jointing with cement mortar including dismantling/taking down/out old pipe complete all as specified and as directed by Engineer-in- charge.
Material & Labour for 75 mm bore cast iron soil waste and vent pipe (sand cast pipe ) in any length with or without ears, laid in trenches or in floor and jointing with cement mortar including dismantling/taking out old pipe complete all as specified and as directed by Engineer-in- charge.
Material & Labour for 100 mm dia cast iron floor trap with CP grating including jointing to waste pipe with solvent fixed in cement concrete (1:2:4) type B-1 using 20 mm graded stone aggregate including taking out old complete all as specified and directed by Engineer-in-Charge.
Supply & fixing in replacement 100mm bore cast iron bends (any radius)/elbo, diminishing pieces or tapers (larger bore measured) without oval access door fixed with cement joints complete all as specified and as directed by Engineer-in- charge.
Supply & fixing in replacement 100mm bore cast iron bends (any radius)/elbo, diminishing pieces or tapers (larger bore measured) with oval access door fixed with cement joints complete all as specified and as directed by Engineer-in- charge.
Supply & fixing in replacement 110mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints for drain or rain water fixed along walls with stack clamps made out of FI 50x5mm and 16mm dia round iron stay (interval of 1m) including PCC work, including dismantling/taking down old pipe complete all as specified and as directed by Engineer-in- charge.
Supply & fixing PVC (SWR) bends without access door (any radius) suitable for 110mm bore pipe fixed to walls or laid in floor complete all as specified and as directed by Engineer-in- charge.
Supply & fixing in repair PTMT Grating doom 125 mm dia with waste hole (Minimum weight 40gms) complete all as specified and as directed by Engineer-in-charge.
Material and labour for preparation of new plastered surfaces of walls/pillars /cornices by brooming down with using broom/sand papering or by any other mean, preparing the surfaces smooth and after preparing the surfaces applying three coats of lime white wash with using paint brush complete all as specified and as directed by Engineer-in-Charge.
Material and labour for preparation of new plastered surface and newly plaster in patch works on surface of walls/pillars /cornices by brooming down with using broom/sand papering or by any other mean, washing down with water and applying two coats of cement base paint as per approved tint/colour with using paint brush complete all as specified and as directed by Engineer-in-Charge.
Material and labour for preparation of new plastered surface and newly plaster in patch works on surface of walls/pillars /cornices by brooming down with using broom/sand papering or by any other mean, preparing the surfaces smooth by applying one coat of chalk whitening as priming coat and after preparing surfaces smooth applying two coats of oil bound distemper (washable) as per approved tint/colour with using paint roller brush complete all as specified and as directed by Engineer-in-Charge.
Note:- The contract sum shall be calculated by deducting the amount shown in Credit Schedule attached to this tender, from total amount of Schedule 'A'/BOQ
BALAJI CONSTRUCTIONS
SAPNA BUILDERS
V K CONTRACTOR
M/s PANKAJ KUMAR
M/s DHEERAJ JAIN CONSTRUCTION COMPANY
M/s Kamal Builders
G N CONSTRUCTIONS
KARTIK BUILDERS
M/s MITTAL CONSTRUCTIONS
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .