| 1 | L1₹32.1 LAccepted-AOC | L1 | Accepted-AOC ACCEPTED BEING L1 | |
| 2 | L2₹42.1 L+₹10.0 L (31.1%)Rejected-AOC | L2 | Rejected-AOC REJECTED DUE TO NOT BEING L1 | |
| 3 | L3₹46.5 L+₹14.4 L (44.9%)Rejected-AOC OLD NO 2C NEW NO 7 1 THANGAVELU VAITHIYAR STREET CORPORATION MIDDLE SCHOOL TRIPLICANE CHENNAI 600005 | CHENNAI | TAMIL NADU | 600005 | L3 | Rejected-AOC REJECTED DUE TO NOT BEING L1 | |
| 4 | L4₹48.7 L+₹16.6 L (51.6%)Rejected-AOC | L4 | Rejected-AOC REJECTED DUE TO NOT BEING L1 | |
| 5 | L5₹49.8 L+₹17.7 L (55.2%)Rejected-AOC NO 235 PSK ILLAM SANKARAN NAGAR CHINNAMMAN KOIL STREET AVADI CHENNAI 600 054 | CHENNAI | THIRUVALLUR | TAMIL NADU | 600054 | L5 | Rejected-AOC REJECTED DUE TO NOT BEING L1 |
Tender Value
₹48.5 L
EMD Value
₹97,000
Closing Date
16 May 2024, 6:00 pmClosed
Garrison Engineer M NAS Arakkonam
Garrison Engineer M NAS Arakkonam 631006
SPECIAL REPAIR TO REPLACEMENT OF UNSERVICEABLE LT UG CABLE AND CONNECTED ITEMS FROM SUB STN H NORA TO STP A AND STP BUS BAR BOX TO T35 AND T36 TO T37 AND FROM T09 TO T11 AND T15 TO T17 AT INS RAJALI ARAKKONAM
2024_MES_650318_1
8347E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Garrison Engineer M NAS Arakkonam
AS PER NIT
7 documents required · 7 mandatory
₹500
Garrison Engineer M NAS Arakkonam
₹97,000
Yes
30 May 2024
18 Apr 2024
18 May 2024
18 Apr 2024
16 May 2024
2 May 2024
Amount
Excavation in trenches, n. exc 1.5 m wide and n. exc 1.5 m in depth for taking up / laying cable etc and getting out for soft/loose soil complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25cm for soft/loose soil complete all as directed.
Removing excavated material n.exc 50m and depositing where directed at a level n.exc 1.5 m above the starting point complete all as directed.
Spreading riddled earth for low thermal resistivity UG cable cushioning complete all as specified and directed
Supply and lay standard size common burnt clay building bricks sub class 'B' for cable protection, laid dry complete all as specified and directed.
Relaying of serviceable bricks here-in-before complete all as specified and as directed.
M&L for tubes light grade galvanised iron pipes of 40 mm sizes with all fittings and fixed under road / culvert/cable protection ,complete all as specified and directed.
Supply and lay pipe galvanised iron tubing light grade of 50 mm dia in trenches/under road or floor/on wall / near pole/panel etc all as per site requirement complete all as specified and directed.
Taking down undert ground XLPE cable of size 16 sqmm 4 core to 120 sqmm 3.5 core from existing cable trench including disconnecting existing cable connections carefully and kee[ it in safe custody for relaying of serviceable portion of cable , complete all as specified and directed.
Supply,laying XLPE insulated, screen, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor of size 16 sqmm 4 core, connecting with proper size Aluminium lugs, glands whereever necessary as per site requiremen , testing complete all as specified and directed. Make:- havells, Polycab, KEI,Gloster
Supply,laying XLPE insulated, screen, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor of size 120 sqmm 3.5 core, connecting with proper size Aluminium lugs, glands whereever necessary as per site requirement, testing complete all as specified and directed. Make:- havells, Polycab, KEI,Gloster
Supply,laying PVC insulated 2.5 Sqmm 3 cpre copper round cable, connecting with proper size Aluminium lugs, glands whereever necessary near all as per site requirement , testing incl taking down complete all as specified and directed. Make:- havells, Polycab, KEI,Gloster
Relaying of serviceable cable of size 16 sqmm 4 core to 25 sqmm 4 core as obtained from site complete all as specified and as directed.
Relaying of serviceable cable of size 120 sqmm 3.5 core as obtained from site complete all as specified and as directed.
Supply and fix cable jointing kit for LT under ground cable for straight through joint complete with Jointing material heat Shrink type and accessories suitable for 4 core XLPE, armoured, Al conductor cable of size 16 sqmm, Indoor/Outdoor type Make:- 3M, Denson, Raychem.
Supply and fix cable jointing kit for LT under ground cable for straight through joint complete with Jointing material heat Shrink type and accessories suitable for 3 ½ core XLPE, armoured, Al conductor cable of size 120 sqmm, Indoor/Outdoor type Make:- 3M, Denson, Raychem.
Supply and fix cable jointing kit for LT under ground cable for end joint complete with Jointing material heat Shrink type and accessories suitable for 3 ½ core XLPE, armoured, Al conductor cable of size 120 sqmm, Indoor/Outdoor type Make:- 3M, Denson, Raychem.
Demolition of cement concrete (unreinforced) of any description and in any position complete all as specified and directed.
PCC for foundation for pole/post where ever necessary 1:4:8 type D-2 (40 mm graded aggregate) complete all as specified and directed.
PCC for coping for Light pole, road cutting etc whereever necessary 1:3:6 type C-1 (20 mm graded aggregate) complete all as specified and directed.
Dismantling steel poles type 410 SP-44 (10.0 metres long), cross-arms of M.S. channel or angle sections etc. including disconnecting existing cable connections carefully keep the good conditional poles in safe custody for refixing the pole a new location with in distance not more than 50 mtr complete all as specified and directed.
Refixing only steel tubular swaged poles type 410 SP-44 (10.0 metres long) complete with cast iron base plate, finial taper plug, bolts, nuts & screws after fixing cross arms MS channels or angle section etc complete all as specified and directed.
M&L Steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-44 (10.0 metres long planting depth 1.8 Mtr and weight not less than 168Kgs) complete all as specified and directed.
M&L Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint complete all as specified and directed.
Taking down old unservicaebl street light pole junction box etc from existing street light poles / wall from existing positions including disconnecting existing cable connections carefully and MS clamps etc complete all as specified and directed.
Refix serviceable street light pole junction box with existing street light poles / wall from existing positions including disconnecting existing cable connections carefully and MS clamps etc complete all as specified and directed.
Supply, Fixing and Testing Powder coated Outdoor street light control box of size not less than 300 x 200 x 80 mm CRCA 3 mm thick IP 65 fabricated by CPRI certified panel manufacturer including suitable terminal TPN 10 KA SMC Connector ( for 3 Phase Cable Line IN & OUT) and provision of dimrail for mounting 3 Nos MCB SP including S&F 01 No MCB 10 A SP C curve , canopy weather proof, hinged door with allen key locking arrangement for fixing on PCC / Steel Poles in and including necessary MS Clamps - 02 Nos of size 300mmx25mmx5mm shape and size with nut, bolts and washers as per site requirement for cemented/steel pole complete all as specified and directed by Engineer-in-charge. Note - (1) The cost deemed to be included in the quoted rate for reconnecting Old existing cables to boxes carefully using a suitable glands and also taking up loop from the under ground and making good in all respect where ever required as per site requirement.
Supply, fabricate, install and testing outdoor type LT bus bar chamber box of size 800x600x400mm from CPRI certified panel manufacturers including provision of dimrail for mounting 1 No of MCCB (MCCB will supply separetely), hinged door with allen key locking arrangement made out of 3mm thick CRCA sheet steel powder coated with front and rear opening slanting cannopy on roof and mild steel channels base frame angles of 50x50x5mm in and including TPN aluminium bus bar of 200A capacity for looping and branch connection, the bus bar placed on suitable capacity insulators including danger notice plate on both side, neoprene rubber gasket to make it completely dust and vermin proof the same will be fixed in ground with necessary PCC foundation made by (1:2:4) type B1 complete all as specified and directed by Engr-in-charge. Note - (1) The cost deemed to be included in the quoted rate for reconnecting Old existing cables to boxes carefully using a suitable glands and also taking up loop from the under ground and making good in all respect where ever required as per site requirement.
Supply and fixing MCCB Adjustable Thermal & Fixed Magnetic setting 415V, 4 Pole of rating 160 Amps, ICS=100%ICU, Breaking capacity 36 KA including additions / altertions to existing MCCB mounting place in the panel for properly fixing and reconnecting In / Out going bus bar or cable connections including s&f extended teriminals as per site requirements and making good distrubed panel surfaces all as specified and directed. Make - Schneider / ABB / Legrand / Siemens
All as per item No- 29 here-in-before but for MCCB of rating 100 Amps, ICS=100%ICU,3 pole, Breaking capacity 16 KA all as specified and directed.
Material and labour for cutting of bituminous road / floor for laying of U/G cables/water line not exceeding 1.5 meter wide and not exceeding 1.5 meter deep including refilling / with material and , watering well ramming / compacting and making good with PCC 1:3:6, type M-10 100mm thick complete all as specified and directed by Eing-in-charge. Note :- PCC shall be measured separately.
PCC (1:3:6) type M-10 using 20 mm graded aggregrate for making good the disturbed surface all as specified and directed by Engineer - in - charge.
Taking down unsereviceable Street light/Flood light from pole/ tower complete disconnecting of electric connection gland not bolt complete and keep in safe custody for repair and reuse wherever necessary complete all as directed by Engr in charge.
Supply and fixing LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal anagement in multiple optics complete with IP 65/66 protection complete all as specified.
Supply and fixing LED flood light 120 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp complete all as specified.
Refixing removed street light/flood light from pole /tower including providing connector,not bolt, tape roll logs etc. complete all as directed by Engr in charge.
Supply and fixing Crompton LED Street light driver of 35-75 wattage complete all as specified.
Supply and fixing Crompton LED Flood light driver of 100-150 wattage complete all as specified.
M&L Earthing complete with GI earth plate electrode of size 600mm x 600mm x 6mm thick buried directly underground vertically (earth pit not less than 2.25m deep below normal ground level) with top edge of the plate at a depth not less than 1.5m below ground level connected with and incl GI Earth wire 4 mm dia , alternate 5 layers of charcoal (250 Kg) & salt crystal (200Kg )and top two inches layers with Back filling compound (100 Kg), in 15 mm dia GI pipe light grade by means of nuts bolts, washers and necessary earth work in any type of soil PCC (1:3:6) type C1 chamber and RCC(1:2:4)type B-1cover and watering pipe 20mm dia medium grade with funnel complete with mesh,refiling with black cotton soil all as specified. Note: (i) Quoted rate deemend to include necessary earth work PCC chamber, RCC cover, renforcement removal of surplus soil , site clearance etc. (ii) GI Earth wire 4mm dia , GI tubing light grade 15 mm dia upto 7.5m deemed to be included the rate quoted by the contractor.(iii) Beyond 7.5 M the GI Earth wire mm dia & GI pipe light grade 15 mm dia shall be measured under the respective item of the schedule..Earthing pit display boards made out of 3 mm thick MS sheet of size 30 x 35 cm welded to 75 cm long 25 x 25 x 5 mm thick MS angle iron grouted in PCC 1 : 3 : 6 (using 20 mm graded stone aggregate) to a depth of 20 cm below GL and including applying two coats of synthetic enamel paint of approved colour over a coat of red oxide primer on all exposed steel surfaces and writing the letters on plate for showing the details :- EARTHING PIT NO : DATE OF MEASUREMENT : NEXT DUE DATE : STANDARD VALUE : VALUE OBTANED : on testing after completion from test point the desired earth resistance shall be not less than 5 ohm .If the desired result is not obtained the earthing will be re done no extra cost.
SREE BALAJI ENTERPRISES
NAVEEN ENTERPRIESES
SHRI S SANTHAKUMAR
PSK Enterprises
Green Ray Technologies
RD ENTERPRISES
lakshmibuilders
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .