Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.4 LAccepted-AOC 403 GH MANSADEVI COMPLEX PANCHKULA 134109 HARYANA | PANCHKULA | HARYANA | 134109 | L1 | Accepted-AOC Being L1 bidder | |
| 2 | L2₹46.4 L+₹15.0 L (47.8%)Rejected-Finance HOUSE NO 251 E BLOCK ADARSH NAGAR BALLABHGARH FARIDABAD 121004 HARYANA | FARIDABAD | FARIDABAD | HARYANA | 121004 | L2 | Rejected-Finance NOT LOWEST | |
| 3 | L3₹47.7 L+₹16.3 L (51.8%)Rejected-Finance HOUSE NO 102 LANE NO 4 C ANAND NAGAR BOHRI JAMMU 180002 J K | JAMMU | JAMMU AND KASHMIR | 180002 | L3 | Rejected-Finance NOT LOWEST | |
| 4 | L4₹50.0 L+₹18.6 L (59.1%)Rejected-Finance H NO 89 BEHIND DD LEH UT LADAKH | LEH | LEH | LADAKH | 194101 | L4 | Rejected-Finance NOT LOWEST | |
| 5 | L5₹51.7 L+₹20.3 L (64.6%)Rejected-Finance AIRPORT ROAD SKALZANGLING LEH LADAKH 194101 | LEH LADAKH | LADAKH | 194101 | L5 | Rejected-Finance NOT LOWEST |
Tender Value
₹46.3 L
EMD Value
₹92,600
Closing Date
14 Oct 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Cdr, HQ 138 WE
HQ 138 Works Engineers PIN-914138 C/O 56 APO
REPAIR REPLACEMENT AND MAINT OF HAMAM STANDALONE CHS AND HEATING DEVICES AT SECTOR A AND SECTOR B UNDER AGE EM II OF GE 865 EWS AT LEH
2023_MES_620381_1
138WE/L-66/2023-24
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE 865 EWS
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE 865 EWS
₹92,600
Yes
11 Jan 2024
23 Sept 2023
21 Oct 2023
23 Sept 2023
14 Oct 2023
7 Oct 2023
Amount
Attending the complaints of Hot Water Plants/Stand alone CHS Plants for checking the burner Assy , Fuel pumps , injectors Starter etc and checking continous electric supply including checking and rectification of electrical fault of Hot Water Boilers/Stand alone CHS Plants installed at various unit locations at Leh area under AGE E/M -II Sub divn making the plants functional incl minor repairs where ever required as per site requirement, complete all as specified and directed by Engr-in-Charge. Note : - The major spare parts for replacement shall be measured and paid separately under respective items of schedule
Supply and Laying XLPE insulated, armoured, haeavy duty electric cables (heavy duty) with stranded aluminium conductor rating 1100 volts grade of size 16 Sqmm 2 core laid in trences or passing through pipes.ducts or fixed to walls/poles (Earth work, cable protection and sand cushioning shall be measured and paid for separately), complete all as specified and directed by Engr-in-Charge.
Supply and laying in replacement XLPE insulated, armoured, haeavy duty electric cables (heavy duty) with stranded aluminium conductor rating 1100 volts grade of size 35 Sqmm 3.5 core laid in trences or passing through pipes.ducts or fixed to walls/poles (Earth work, cable protection and sand cushioning shall be measured and paid for separately), complete all as specified and directed by Engr-in-Charge.
Excavation in trenches in hard/dense soil, n.exc 1.5 m wide and n. exc 1.5m in depth, for foundation, laying of cable ,etc or for shafts, wells, cesspits, manholes pier holes etc nexc 10 sqm on plan and n exc 1.5 m in depth and getting out, complete all as specified and directed by Engr-in-Charge.
Removing of surplus excavated material to a distance n. exceeding 50 mtr & depositing where directed at a level n. exceeding 1.5 mtr above the starting point , complete all as specified and directed by Engr-in-Charge.
Returning filling in including spreading, leveling, watering & well ramming in layers n. exceeding 25 cm thick, complete all as specified and directed by Engr-in-Charge.
Sand cushioning to underground cables 8 cm below the cable before laying & 15 cm above the cable after laying, in clause 19.75 of SSR Par-I, complete all as specified and directed by Engr-in-Charge.
Replacement of factory made, machine pressed, unreinforced, pre-cast concrete cable cover class LV type-I flate size 250 x 150x40mm, complete all as specified and directed by Engr-in-Charge.
M&L for replacement of photocell suitable for 0.5/1.0/1.5 Lakh Kilo/Cal/hr burner complete all as specified and as directed by Engr-in-Charge.
M&L for replacement of Ignition Transformer electronicl type suitable for 0.5/1.0/1.5 Lakh Kilo/Cal/hr burner rod assy , complete all as specified and directed by Engr-in-Charge.
M&L for replacement of diesel filter as per existing complete all as specified and directed by Engr-in-Charge.
S&F in replacement of High pressure fuel pipe 1.5 mtr as per existing, complete all as specified and directed by Engr-in-Charge.
M&L for replacement of Push botton type ON/OFF switches as per existing complete all as specified and directed by Engr-in-Charge.
S&F in replacement of Electrode suitable for burner of capacity 0.5/1.0/1.5 lakh K/Cal/Hr complete all as specified and directed by Engr-in-Charge.
S&F in replacement of Rotary type switch as per existing model & type,complete all as specified and directed by Engr-in-Charge.
M&L for replacement of Indicating lamps RYB as per existing complete all as specified and directed by Engr-in-Charge.
M&L for replacement of Digital type volt meter complete with touch control switch 0-500 volts complete all as specified and directed by Engr-in-Charge.
M&L for replacement of Digital type Amp meter complete with touch control switch and suitable CTs 0-300 Amps complete all as specified and directed by Engr-in-Charge.
S&F in replacement of oil pressure pump suitable for burner of capacity 0.5/1.0/1.5 lakh K/Cal/Hr AS47A, complete all as specified and directed by Engr-in-Charge.
M&L for sequence controller suitable for 0.5/1.0/1.5 lakh Kilo/Cal/hr burner rod assembly complete with all electric connection complete all as specified and directed by Engr-in-Charge.
M&L for replacement of thermostat assembly tail type as per existing suitable for 50-300 degree centigrade temperature complete all as specified and directed by Engr-in-Charge.
S&F temp controller digital type DTC 503 with sensor suitable for 0.5/1.5 lakh kilo/Cal/hr LAL 2.25 burner rod assembly, complete all as specified and directed by Engr-in-Charge.
S&F in replacement of burner nozzle suitable for 0.5/1.0/1.5 lakh K/Cal/Hr complete all as specified and directed by Engr-in-Charge.
M&L for replacement of over load relay 10 to 18 amp complete all as specified and directed by Engr-in-Charge.
S&F in replacement of PVC flexible copper multistrand wire 3 core of 6 sqmm as per existing, complete all as specified and directed by Engr-in-Charge.
S&F in replacement of PVC flexible copper multistrand wire 2 core of 6 sqmm as per existing, complete all as specified and directed by Engr-in-Charge.
Supply and fixing 50mm dia Gun-metal globe or gate valve, with iron wheel head, screwed both ends for iron/GI pipeand fixed complete all as specified and directed by Engr-in-Charge.
Supply and fixing 40mm dia Gun-metal globe or gate valve, with iron wheel head, screwed both ends for iron/GI pipeand fixed complete all as specified and directed by Engr-in-Charge.
Supply and fixing 25 mm dia Gun-metal globe or gate valve, with iron wheel head, screwed both ends for iron/GI pipeand fixed complete all as specified and directed by Engr-in-Charge.
M&L for replacement of MK I Starter as per existing complete all as specified and directed by Engr-in-Charge.
Supply and laying 40mm bore dia 3 layer PPR Polypropylene random copolymer) pipes SDR 7.4 & SDR 11 UV stablised and antimicrobial fusion welded having thermal stability for hot & cold water supply all PPR plain & brass threaded polypropylene random fittings laid in trenches, complete all as specified and directed by Engr-in-Charge.
All as per item ser No 31 but of size 50mm bore dia, , complete all as specified and directed by Engr-in-Charge.
All as per item ser no 31 but of size 25mm bore dia, complete all as specified and directed by Engr-in-Charge.
All as per item ser No 31 but of size 20mm bore dia , complete all as specified and directed by Engr-in-Charge.
M & L for lagging for 25mm bore dia pipes to be used in water supply all round with 40 mm thick bonded mineral wool preformed ‘SNAP ON’ pipe sections of density 144 kgs / Cum conforming to IS 9842 and providing chicken mess wire netting 25 guage 20 mm mesh and covered with aluminum foil 0.01 mm, complete all as specified and directed by Engr-in-Charge.
All as per item ser No 35 but for size 40mm dia bore pipes, complete all as specified and directed by Engr-in-Charge.
All as per item ser No 35 but for size 50mm dia bore pipes, complete all as specified and directed by Engr-in-Charge.
All as per item ser No 35 but for size 20mm dia bore pipes, complete all as specified and directed by Engr-in-Charge.
Material and labour for rewinding of electric motor 3 phase 415 volts of capacity 3/5 HP with superior quality super enameled copper winding wire of appropriate size and gauge as existing including varnishing , cotton tape, PVC sleeves etc, complete all as specified and directed by Engr-in-Charge.
M&L for dismantling of burner assembly and removing of side cover of boiler capacity 1.0/1.5 Kilo/Cal/hr and complete serviceing the boiler by using coil shine chemical and removing the complete carbon/oil deposites including repair to coil assembly if there is any leakage found or any other repair required at site and reassembling/testing the same complete all as specified and directed by Engr-in-Charge
M&L for dismantling of burner assembly of stand alone CHS and removing of side cover of boiler capacity 0.5/0.35 Kilo/Cal/hr and complete servicing the boiler by using coil shine chemical and removing the complete carbon/oil deposites including repair to coil assembly if there is any leakage found or any other repair required at site and reassembling/testing the same complete all as specified and directed by Engr-in-Charge
S&F in replacement of Burner Assembly including fixing the assembly in the existing Hot water Boiler incl making necessary arrangments with all required fixing materials and made functional the Hot water Boiler of Capacity upto 1.0 LKCal/Hr and testing after completetion complete all as directed by the Engr-in-charge.
S&F in replacement of Burner Assembly including fixing the assembly in the existing Hot water Boiler/stand alone CHS incl making necessary arrangments with all required fixing materials and made functional the Hot water Boiler/Stand Alone CHS of Capacity 0.5/0.35 LKCal/Hr and testing after completetion complete all as directed by the Engr-in-charge.
Supply and fixing of PVC heavy duty vertical type fuel storage tank of 50 Ltrs capacity with necessary connection at bottom for fuel pipe of suitable size, complete all as specified and directed by Engr-in-Charge.
M&L for under deck insulation with PUF slab including application of cold bitumen on PUF slab, steel wire of size 46 gauge fixed , for fastening of 60mm PUF slab, suitable for steel sheet duct of any size, complete all as specified and directed by Engr-in-Charge.
national engineering
SUMEET TRADING CORPORATION
M/S HIGHLAND ENGINEERING
M/S NANCY ENTERPRISES
M/S MALIK CHAND SIRI RAM
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .