| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.8 LAccepted-AOC 17 1 ABHOY HALDER LANE KOLKATA | KOLKATA | L1 | Accepted-AOC LOWEST RATE | |
| 2 | L2₹24.2 L+₹42,385 (1.78%)Rejected-Finance 6 KRIPANATH DUTTA ROAD KOLKATA 700 002 | KOLKATA | KOLKATA | WEST BENGAL | 700002 | L2 | Rejected-Finance HIGH RATE | |
| 3 | L3₹24.3 L+₹53,859 (2.27%)Rejected-Finance | L3 | Rejected-Finance HIGH RATE | |
| 4 | Rejected-Technical LAKE ROAD LAKE TOWN WEST SILIGURI 734007 | SILIGURI | DARJEELING | WEST BENGAL | 734007 | - | Rejected-Technical INSUFFICIENT TENDER DUCUMENTS |
Tender Value
Refer Docs
EMD Value
₹47,600
Closing Date
23 Sept 2022, 4:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer
P-16, India Exchange Place Extn CIT Annexe Bdg.Kol 73
Supply and installation of Safety fire Equipment at Naihati Hospital under Eastern Mechanical Division, P.H.E. Dte.
2022_PHED_399770_6
WBPHED/EE/EMD/NIET/12/2022-23
Open Tender
Miscellaneous Works
Item Rate
30 days
P-16, India Exchange Place Extn CIT Annexe Bdg.Kol
Please refer Tender documents.
6 documents required · 6 mandatory
₹47,600
19 Nov 2022
5 Sept 2022
26 Sept 2022
5 Sept 2022
23 Sept 2022
6 Sept 2022
Amount
Supply & delivery of following portable fire extinguisher:
a) ABC Powder Type Fire Extinguishers (Stored Pressure) Capacity – 4 Kgs.
b) Co2 Type Fire Extinguishers (Capacity – 3 Kgs.)
Supply, delivery Installation, Testing & Commissioning of Microprocessor based 4 Loop fire alarm control panel (VDS & FN 54 approved) fully networkable with each loop capable of taking 125 devices display character alpha- numeric liquid crystal display the panel shall be soft addressable type. The panel shall be able to give pin point location of all fire/fault conditions. Further, the panel must be able to automatically switch off respective control switches when ever any alarm is triggered. The panel shall have in built rectifier, provision for external & internal printer (if required), Loop cards, LCD unit to indicate Fire/Fault Signal with address and analog output, complete in all respects, having 200 event memory, integral SMF lead acid batteries with sealed cells of 24Vcapable of running for a minimum of 8 hours with integral battery charger complete as required and as per specification.
Supply, delivery, installation testing and commissioning of PA CONSOLE complete with amplifier (capacity 300 watts) microphone, 6 Hours battery backup and battery charger MS battery box & support as per direction of the Engineer-in-charge.
Supply, delivery, Installation, testing & Commissioning of Analog Addressable intelligent multisensory detector (VDS & EN 54 approved) as well as additional heat detector sensor with decentralize intelligence, soft addressable Photo thermal type as per NFPA style 7 wiring complete with base as required.
Supply, delivery, installation, Testing & Commissioning of Analogue Addressable Intelligent heat Detector (VDS & EN 54 approved) with fixed & rate of rise temperature function with decentralize intelligence, soft addressable type as per NFPA style 7 wiring complete with base as required.
Supply, delivery, Installation, Testing & Commissioning of Addressable Manual Call Point (VDS & EN 54 approved) soft addressable type as per NFPA style 7 wiring complete as required.
Supply, Installation, Testing & Commissioning of addressable Hooter (sound output of minimum 90 db) cum strobe (VDS & EN 54 approved) (Strength of light 10 cd) complete with base and as required.
Supply, Installation, testing and commissioning of SPEAKER (6w) complete with base, mounting box, gland, lugs, etc. as required completing in all respect.
Supply, Installation, Testing & Commissioning of Analogue addressable intelligent Response Indicator will all accessories complete of approved band and complete with base as required.
Supply, Installation, Testing & Commissioning of 1KVA offline UPS, pure sine wave out put on UPS (inverter) mode with 15 min battery backup back up at rated load.
Supply, delivery and laying of 20 mm PVC conduit.on wall for smoke detector wiring
Supply, erection, testing & commissioning of 2C x 1.5 mm2 Cu Control Cable.
Add: GST @ 18%
Add: LW Cess @ 1%
B T PROJECTS PRIVATE LIMITED
T N BANERJEE
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .