Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.6 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹35.7 L+₹5.8 L (19.4%)Rejected-AOC H NO 279 SHAHEED NAGAR AGRA | AGRA | L2 | Rejected-AOC L2 | |
| 3 | L3₹37.9 L+₹8.0 L (26.7%)Rejected-AOC | L3 | Rejected-AOC L3 | |
| 4 | L4₹45.7 L+₹15.8 L (52.9%)Rejected-AOC | L4 | Rejected-AOC L4 |
Tender Value
₹49 L
EMD Value
₹98,000
Closing Date
5 Aug 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Bharatpur
GE Bharatpur, Kanjoli line Bharatpur-321026
Repair to certain B/R works at parade ground under GE Bharatpur
2023_MES_603017_1
8264/E8
Open Tender
Civil Works
Item Rate
180 days
Bharatpur
As per NIT
6 documents required · 6 mandatory
₹500
GE Bharatpur
₹98,000
Yes
14 Sept 2023
13 Jun 2023
7 Aug 2023
13 Jun 2023
5 Aug 2023
22 Jul 2023
14 Jun 2023 - 25 Jun 2023
Amount
Taking down cement plaster or cement lime plaster on PCC/stone surface/brick surfaces including raking out joints hacking for key scrubbing down with water etc complete all as specified and directed.
M & L rendering 15 mm thick in CM (1:4) on fair faces of brick work or concrete surfaces finished even & smooth without using extra cement, complete all as specified and directed.
All as per item No. 2 above but in CM (1:6) finished even and smooth without using extra cement complete all as specified and directed.
M&L for rendering 10mm thick in cement mortar 1:4 on concrete surfaces including finished even & smooth without using extra cement on ceiling complete all as specified and directed.
M&L for two coat of Apex exteriar paint on treated surfaces of walls, white or tinted including preparation of surfaces complete all as specified and directed.
M & L Preparation of new decorated plastered surfaces of wall including cornices, pilasters etc by brooming down and applying two coats of cement base paint of approved shade on walls with hand roller complete all as specified and as directed by Engr-in-Charge
M & L Preparation of new decorated plastered unplastered surfaces surface of wall including cornices, pilasters etc by brooming down and applying Three coats of white wash on walls complete all as specified and directed.
M & L Preparation of new decorated plastered unplastered surfaces surface of wall including cornices, pilasters etc by brooming down and applying two coats of oil bound distemper over 1.5mm wall care putty (inTwo Coat) of approved shade on walls by roller complete all as specified & directed by Engineer-in-Charge.
M&L for three coats of white wash on new plastered or unplastered surfaces of Ceilings including prepration of surfaces complete all as specified and directed.
Razing off/ taking down old existing unserviceable cement plaster, loose / unsound weaken cement concrete of any description and in any position from existing external / internal surfaces of RCC roof / slab / beams / columns / RCC facias, or any surface average depth 25mm (Approx height 15.0 m from natural ground level) with power driven of pneumatic chisel and and removal up to the approval municipal dumping grounds specified by the local bodies outside MOD land including cutting of all edges, making square shoulders of the cavities, roughening the smooth surfaces, scrapping out / removing corrosion all loose / scale / rust etc from the visible unplastered surface and applying one coat of styrene butadiene polymerized cement mortar Modifier TM-BOND® SBR or AR. Make of -Thermax/chemco system/webac chemicals. for B/P the surface before application of rheoplastic cementious based repair conforming to BS 6319. Ensuring no porosity in new surface complete all as specified and directed by Engr-in-charge. Note—this item shall be undertaken by the authorized rep of manufacturer.
M&L for drilling hole in RCC/Bricks structures using drilling machine up to a depth of 50 mm and 15 mm dia, with the gap of 600mm removing dust, etc by vacuum cleaner and blowers, providing and fixing of heavy grade GI pipe nipple 15 mm dia, 50 mm long, @ 1.0 mtr c/c in both direction and injection cement slurry mixed with liquid integral waterproofing additive WAREP 1000L for concrete conforming to EN 934-2 T9 confirms to IS 2645-2003. Make of -Thermax/chemco system/webac chemicals. having specific gravity 1.1-1.2 gms/cc, chloride content: Nil as per IS 2645-2003 in combination with expanding powered or dual shrinkage compensating non shrink free flow plasticized grouts conforming to the requirements of BS EN 1504-3 class R4. And directed by GE, complete all as specified and directed by Engr-in-charge. Note—this item shall be undertaken by the authorized rep of manufacturer.
M&L for providing 25 mm thick one COMPONENT BS 5F chloride free thixotropic fibre reinforced polymer modified repair mortar 5F complies with ASTM C 109 with flexural strength ASTM C 348 @ 7 days meeting 7N/mm2 and tensile strength @ 7 days (ASTM C 307) >3 N/mm2 at the outer or inner Brick or stone walls in cement mortar in the ratio 1:4 mixed with styrene butydiene polymerized cement mortar Modifier TM-BOND® SBR or AR for bonding with cementious mortar specially adhered to BS 6319 having specific gravity of 1.025 to 1.04, minimum 43% solid contents) not less than 2% by weight of cement and as per manufacturer,s instructions. for external or internal surface of RCC /slab /beam /columns/facias/any brick or stone wall surface etc. Make of -Thermax/chemco system/webac chemicals top surfaces of the plaster shall be finished even and smooth with using extra cement including taking down of old cement plaster and dispose of to a distance to 50 mtr. etc complete all as specified and directed. Note—This item shall be undertaken by the authorized rep of manufacturer.
M&L for providing and applying Rheoplastic non shrink, corrosion resistant, High strength compound BS 66 MuCis on external or internal surface of RCC roof/floors/ceilings/chhazas /slab/balconies /beam /columns/facias/any brick or stone iner or outer wall surface etc, BS 66 having compressive strength as Bs 4551-80 thickness of40- 50mm with 1:4 cement mortar and strength (ASTM C 109)-80 Mpa @ 28 days, Tensile strength 2.0N/mm2 @ 28 days (ASTM C 348)- 4 Mpa @ 28 days, Flextural strength 10N/mm2 (ASTM C 348)-11 Mpa @ 28 days, Young's modulus -27 KN/sqmm (ASTM D469), Expansion charactristics (ASTM C 827-1987) Unrestrained expansion upto 4% pressure to restrain plastic Expansion -Approx. 0.004 N/sqmm make of- thermax/chemco system/webac chemicals., before pouring micro concrete it is recommended to apply granolithic E-Resin based solvent free concrete bonding agent/EP in accurate proportion with complete homogenesity. make of Thermax / Chemco system / Webac Chemicals having mix density of 1.45 to 1.5 kg/litre, Compressive strength (BS 6319 pt.2)-40 Mpa at 7 days, Flextural strength (BS 6319 pt.3)- 25 Mpa at 7 days, Tensile strength (BS 6319 pt.7)- 15 Mpa at 7 days, Bond strength (ASTM C 881)- 11 N/sqmm at 7 days, having an over lay time of 03 hrs at 30 C. pouring of micro concrete into the formwork using suitable arrangement or required using pumping device for uniform flow of micro concrete. The side shuttering can be removed after 3 days, and the bottom shuttering after 7 days, ensuring proper bond between the micro concrete and existing concrete substrate etc. complete including all tools and tackles as directed by Engr-in-Charge. Note: - Rate quoted shall include for necessary formwork required in the item. Note- this item shall be undertaken by the authorized rep of manufacturer.
M&L for providing and fixing welded MS wire mesh weighing not less than 1.5 kg/sqm and applying - Mucis protezioz ferro mono primer (single component cementitous corrosion inhibiting primer) of make Thermax Ltd or equivalent of webac chemicals /chemco system on exposed steel reinforcement and wire mesh having Mixed density of 2.01 to 2.05 Adhesive bond strength - 1N/mm2 touch drying time of 10-15 minutes at 35 degree celcius and recoable time 30 minutes and applying 25 mm thick COMPONENT BS 5F chloride free thixotropic fibre reinforced polymer modified with guniting machine/shotgun pressure not less than 5kg per sqr in the ratio of 1:4 mixed with liquied water proofing admixture (warep of make Thermax Ltd or equivalent ) complete all as specified and directed.
M &L for curing of the surface using Maxcure CC 75 curing efficiency; Make of -Thermax/chemco system/webac chemicals. Maxcure CC 75 complies with the internationally recognized ASTM C309-90 standards incuding all tools and tackles, complete all as specified and directed by Engr-in-charge. Note—this item shall be undertaken by the authorized rep of manufacturer.
Note : for item No. 10,11,12,13,14 & 15 (i) MEMORUNDUM OF UNDER STANDING The tenderer shall submit the memorundum of under standing (MOU) from the manufacturer to execute the item with trained persons for application within 15 days from the date of commencement of the work as per date mentioned in work order No. 1, if he fails to submit MOU with in 15 days he will not be allowed to commence the work. No extension of time will be granted for the period of lapse in submission of MOU.
Demolition of brick work or stone/boulder masonry built in cement mortar including all quoin jambs pillars etc, complete all as specified and directed.
M&L Brick work with sub class 'B' old size bricks straight or curved on plan exceeding 6 m mean radius built in cement mortar 1:6 complete all as specified and directed.
Ditto but except bricks
Demolition of PCC in ground floors and pavings not exc 15cm thickness ( below or above ground level ) complete all as specified and directed.
Demolition of RCC (reinforcement cut as required to facilitate demolition) in ground floors and pavings not exc 15cm thickness ( below or above ground level ) complete all as specified and directed.
S&F Precast reinforced (SFRC) Man holes covers with frames(medium duty) of any size as per requirement all as directed by Engineer-in-charge complete all as specified and directed.
M&L for PCC 1:3:6 type C1 (using 20mm graded stone aggregate) as in plinth protection, 75mm thick finished even and smooth without using extra cement complete all as specified and directed.
M&L for PCC 1:2:4 type B1 using 20mm graded stone aggregate as in flooring, 40mm thick, finished even and smooth with using extra cement complete all as specified and directed.
M&L 100 mm thick PCC 1:4:8 type D-2 (using 40mm graded aggregate) in sub base /sub floor complete all as specified and directed.
M&L Sand cusion under floor ,spreading and levelling in layers 25 mm thick complete all as specified and directed.
M&L for 80mm thick & M-40 factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould/rubber molded, laid in required colour & pattern over 25mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand, complete all as specified and directed of Engineer-in-Charge. Note : Sand for cushion shall be measured & paid under respective item of BOQ.
M&L for factory made kerb stone of plain cement concrete (1:2:4) type B-1(using 20 mm graded stone aggregate) , of size depth 450mm , thickness 150 mm and length n.exc. 500 mm set and jointed in cement mortar (1:4) incl painting work complete all as specified and direted.
Dismantling floor, hearth or wall tiling including cement mortar bedding ( but not backing ), removing serviceable tiling to store and rubbish off the premises Complete all as specified and directed.
M&L for non-skid coloured Glazed ceramic tiles in vertical surface 350x 250x 7 mm/ 450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match laid over and including 10 mm thick plaster in CM (1:4) complete all as specfied and directed.
M&L for coloured Non Skid Ceramic tiles 7 to 8mm thick (square/rectangular) area of each tiles exceeding 0.11 sqm but not exceeding 0.18 sqm , over and including 15 mm thick screed bed in CM 1:6 in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match all as directed by Engineer-in-charge complete all as specified and directed.
M&L for Vitrified Light Shade ceramic tiles 10 mm thick (Square/rectangular) area of each tile not exceeding 0.36 sqm , over and including 15 mm thick screed bed in CM 1:6 in floors etc, set and jointed in neat cement slurry and pointed in coloured cement to match complete all as specified and directed.
Dismantling of stone slab and tiles of any description or thickness in floors, etc laid beded and pointed in any mortar complete all as specified and directed.
M&L for 20 mm thick Granite (of any type) tiles/slab in skirting/dados over and including baking coat 15 mm thick in cement mortar 1:4, laid and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including rubbing and polishing complete all as specified and directed.
M & L for 20 mm thick, Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including point?ing in white cement (1:2) us?ing marble dust with admix?ture of pigment to match with shade of granite complete all as specified and directed.
M&L for 18-20 mm thick machine cut kota stone slab flooring over and including cement screed 20 mm thick in cement mortar 1:6, laid and jointed with gray cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed.
M&L for Machine cut kota stone slab 18-20 mm thick in riser of steps, skirting, dedo and pillar laid over cement screed 15 mm thick in cement mortar 1:4, laid and jointed with gray cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed.
S &F in repair of triple layered (White Colour) rotational moulded polyethylene water storage tanks 500 Ltr (cylinderical vertical with closed top) with 20mm dia ball brass valves,high pressure , with polythene float and flynut including dismantling of existing water tank of capacity exc 250 Ltr & n exc 500 Ltr, complete all as specified and directed.
S & F in repairs for single piece-WC with UF soft close slim seat cover, fixing accessories, accessories set and cistern fitting, size 365x 655x 760mm strap 220mm complete all as specified and directed. Make - Jaguar or equivalent specified in Appx 'B'
Taking down chowkats or frames exc. 1.5 sqm but not exc. 4 sqm each (without taking off shutters from frames) Complete all as specified and directed.
Providing and fixing in repair12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & double action hydraulic floor spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, complete all as specified and directed . Note :- Rate of door handle, lock and stopper etc deemed to included in quoted rate.
Dismantling wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation, boards/slabs/blankets, any thickness, including cover fillets and frame work complete all as specified and directed.
S&F PVC wall panelling in repair with panel of 300 mm x 6 mm Hollow section of Sintex pattern SPUF- 146 or equivalent , fixed with PVC plug and screw and inserted to next panel groove, edges and corners of all door/ window/openings etc to be covered with PVC angle fixed with solvent cement complete all as specified as manufacturer's Instructions
M&L for providing and fixing Gypsum Board 12 mm thick in ceiling fixed with screws as per manufacturers instructions complete all as specified and directed.
S&F anodised aluminium snap grid frame work of size 605x605mm for false ceiling complete all as specified and directed.
S&F hangers 6mm dia. G.I. (up to 1200 mm length ) adjusting level fixed to roof slab by means of ceiling cleats made out of GI flat 40x3mm size 60 mm long and hold fasterners 12.5mm dia 40mm long, complete all as specified and directed.
Dismantling of Stone Jali & Stone Pillar of any description , any thickness complete all as specified and directed.
M&L for 40 mm thick Sikandra stone jali decorative design of approved pattern by Eng-in-charge including all carving and moulding of corners fixed in cement mortar 1:4 to grooves of stone pillars application with colouring to match with colour of jali including fixing of stone jali for all corners & lift complete all as specified and directed of Engineer in-charge.
S&F stone pillars(post) of size 100x100 mm including engraving decorative design of approved pattern on two face and dome shape approved by GE , height of each post as per sikandra jali, ,making groove on two face of size 43x5 mm for fixing of sikandra Jali in CM 1:4 complete all as specified and directed by Engineer in-charge.
abhinav and company
M/S MAMTA CONSTRUCTIONS
M/s Ranaji Construction Co
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .