| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.3 LAccepted-AOC | L1 | Accepted-AOC Accept | |
| 2 | L2₹5.4 L+₹8,166.55 (1.55%)Rejected-AOC | L2 | Rejected-AOC Reject | |
| 3 | L3₹5.5 L+₹19,991.76 (3.79%)Rejected-AOC VPO GUDHA DISTT M GARH | M GARH | L3 | Rejected-AOC Reject |
Tender Value
₹4.7 L
EMD Value
₹9,440
Closing Date
8 Dec 2022, 12:00 pmClosed
Executive Engineer, M/Garh Canal W/S Division, NNL
Executive Engineer, M/Garh Canal W/S Division, NNL
Laying RCC pipe line 300mm i/d for Recharging Purpose in Village pond Chindalia from Extension of Dhuna Mandir Pond pipeline near School from Km 10.931/Tail of Dochana Disty. (Re-invited)
2022_HRY_248145_1
20222B84F63B E254 4E51 B1D0 E343846F5311159IRR
Open Tender
Civil Works
Works
120 days
CHINDALIA
Laying RCC pipe line 300mm i/d for Recharging Purpose in Village pond Chindalia
4 documents required · 4 mandatory
₹500
₹9,440
Yes
27 Mar 2023
1 Dec 2022
8 Dec 2022
1 Dec 2022
8 Dec 2022
1 Dec 2022
Amount
[HSR 11.5.3]12 mm cement plaster of mix : 1:4 (1 cement: 4 fine sand) Through Rate
[HSR 20.62.3]Providing, lowering, laying, cutting (cut surface to be uniformly finished), jointing with rubber rings marked with IS : 5382 and testing of SPIGOT AND SOCKETTED RCC, NP2 MARKED WITH IS : 458-1988 and specials into trenches for all depths including carriage, loading, unloading, stacking, handling, re-handling etc. complete is all respects to the satisfaction to the Engineer - in -charge. 3. 300 mm i/d Through Rate
[HSR 4.12.1]Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead up to 50 m and lift up to 1.5 m, as directed by Engineer-in-charge. 1. All kinds of soil Through Rate
[HSR 4.16.1.2]Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m : 1.2. Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia Through Rate
[HSR 4.17]Extra for excavating trenches for pipes, cables etc. in all kinds of soil for depth exceeding 1.5 m, but not exceeding 3 m. (Rate is over corresponding basic item for depth up to 1.5 metre). Through Rate
[HSR 6.1.2]Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work below plinth level and up to Floor IV level: 2. 1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size) Through Rate
[HSR 6.1.6]Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work below plinth level and up to Floor IV level: 6. 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size) Through Rate
[HSR 6.33.3]Steel reinforcement for R.C.C. work, where not included in the complete rate of RCC, including straightening, cutting, bending, placing in position, binding, wastage, overlaps, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire etc. complete in all respect below plinth level 3. Cold twisted bars Through Rate
[HSR 6.44]Providing, hoisting and fixing up to floor four level precast reinforced cement concrete in small lintels not exceeding 1.5m clear span up to floor four level, including the cost of required centering, shuttering but , excluding the cost of reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). Through Rate
[HSR 7.21.1]Brick work with common burnt clay non-modular bricks of class designation 10.5 in foundation and plinth in: 1. Cement mortar 1:4 (1 cement : 4 coarse sand) Through Rate
[HSR 9.57.2]Providing and fixing on wall face Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 2. 110 mm diameter Through Rate
SHIVAY BUILDCON
DHARAMBIR S/O BUDH RAM
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .