Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹90.8 LAccepted-AOC MHN 284 DRIVER HILL VASCO DA GAMA GOA 403 802 | SOUTH GOA | GOA | 403802 | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹97.5 L+₹6.1 L (6.73%)Rejected-Finance FLAT NO 4 VIRGINIA CO OP HOUSING SOCIETY AIR PORT ROAD CHICALIM VASCO DA GAMA GOA 403 711 | SOUTH GOA | GOA | 403711 | L2 | Rejected-Finance HIGHER BIDDER | |
| 3 | L3₹1.0 Cr+₹9.8 L (10.7%)Rejected-Finance | L3 | Rejected-Finance HIGHER BIDDER | |
| 4 | L4₹1.0 Cr+₹11.3 L (12.3%)Rejected-Finance C2 PAIXOMONTIRO APTS BEHIND NSD ALTO DABOLIM VASCO DA GAMA GOA 403 801 | SOUTH GOA | GOA | 403801 | L4 | Rejected-Finance HIGHER BIDDER | |
| 5 | L5₹1.1 Cr+₹13.9 L (15.2%)Rejected-Finance | L5 | Rejected-Finance HIGHER BIDDER |
Tender Value
₹1.1 Cr
EMD Value
₹1.9 L
Closing Date
15 Jun 2020, 6:00 pmClosed
SH M V SANKAR SE CWE
CWE NAVY VASCO VASCO DA GAMA GOA 403802
SPECIAL REPAIRS TO STS HANGAR ASSOCIATED ROOM AND OFFICES BUILDING NO P 419 AT NAY GOA UNDER GE NW VASCO
2020_MES_343554_1
85257/E8
Open Tender
Civil Works
Item Rate
270 days
CWE NAVY VASCO
AS PER TENDER DOCUMENTS
9 documents required · 9 mandatory
₹1,000
Yes
GE NW VASCO
₹1.9 L
Yes
30 Sept 2020
8 May 2020
18 Jun 2020
8 May 2020
15 Jun 2020
1 Jun 2020
Amount
Schedule 'A' -Part I ( B&R Works)
M&L for chipping , removing carefullly the concrete work by low impact hammer ,breakar without damaging the structure & cleaning and disposal of debries out side the premises etc complete all as specified and as directed. Note: Hard concrete shall not be removed by force.
M&L for cleaning existing reinforcement with wire/rotary wire brush, making the surfaces free from loose material dirt etc complete and applying two coats of alkaline rust converting primer FEOVERT of Krishna conchem or Dr. Fixit equivalent conforming to ASTM-B-117, on the rebars, including cleaning the reinforcement, wire brushing to remove loose rust spalls, with time interval of 6 hour between the coats and applying protective coating IPNET-RB all as specified and as directed.
M & L for carrying out Bi-polar migratory corrosion inhibitor EPCO-KP-100 or equivalent on concrete surface. This inhibitor shall have migratory kind of property which permits the material to migrate to a vertical extent of 100mm , through pores of concrete, inhibiting the corrosion and de-passivating the electro-chemical reaction , it should have property to attract anode as well as cathode , which is purely alkaline in nature(Ph-9.5) so it has no carcinogen activity with concrete all as specified and as directed.
M&L for providing and applying structural grade EPIBOND-21-LP prior to application of any type of mortar plaster conforming to ASTM-C-882-91 (Arizona Slant Shear Test) to ensure bond between old concrete and new concrete all as specified and as directed.
M&L for building up the profile of structural members by using latex additives(MONOBOND) modified air cured mortar system (Polymer modified mortar) (1:5:15 = 1 monobond-5 Cement-15 sand) -in damaged areas in 30mm thickness including leveling profiling etc all as specified and as directed.
M&L for drilling and fixing Rohibb Teflon nozzles in RCC members, including drilling holes of 12mm dia, 50 to 100mm deep holes in structural members at the intervals of 500 mm center to center in staggered manner or as directed in RCC structural element. Work shall be carried out as under :- (i) Cleaning of holes. Clean the holes by air blower prior to fixing nozzles. (ii) Fixing of nozzles. Insert 12mm dia. Rohibb Teflon nozzles in cleaned holes. External end of nozzles to be machine to receive outlet of grouting gun. Fix it inside the holes by applying thixotropic epoxy putty to ensure complete sealing. Cure the system for minimum of about 12 hrs. (iii) Cutting of nozzles. Cut the nozzles by chisel after completion of grouting without damaging structural elements.
M&L for Injecting of site cement slurry grout, in the ratio 1:2 (1- Cement, 2-water) including super plasticizer (Supercom-100) 250 ml/50 Kgs of cement mixing shall be done by mechanical mixer continuously stirring mechanically to keep cement particles in suspension. Injection of approved/ specified grout by means of pump at a pressure of 0.5 Kg/cm2 etc complete till the grout mix flows out from the nozzle indicating complete filling of grout in the holes drilled for repair to wall & slab all as specified and as directed.
M&L for injecting low viscosity MONOPOL (3-5cps) high molecular weight monomer by pressure and using mechanized injector gun with accessories till nozzles refuses to accept the grout, including, mixing of materials :mixing of material components(part a&b) in the required quantities as per manufacturer's instruction by weigh batching .Grouting maintain the pressure at exit 0.5 to 1.0 kg/cm2 by monitoring pressure guage at exit. Grout the material through prefixed nozzles in the structural elements at the rate of 100ml per nozzle. Repeat the process for all the nozzles in beam and columns all as specified and as directed.
M&L for providing and applying jacketing around columns with micro concrete (Molith-MC) M40 including all lifts, shuttering, drilling holes and fixing shear anchor as per specifications complete. Notes: (i) Reinforcement shall be measured and paid separately. (ii) Quoted rates shall include for jacketing, formwork and micro concrete.
M&L for replacement of steel reinforcement with TMT CRS bars of appropriate size where 20% of cross section is reduced including dismantling of rusted steel including application of rust converter FEOVERT and applying protective coating IPNET-RB all as specified and as directed.
S&F hard drawn steel wire fabric cut to length bent to shape required and tying with and including mild steel wire (annealed) not less than 0.9 mm dia not exceeding 4 Kg/sqm all as specified and as directed.
Dismantling plain or corrugated steel sheeting of any gauge, thickness, including Naintal or similar pattern roof coverings all as specified and as directed.
S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws all as specified and as directed.
Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to store (measured overall as fixed along the centre line over fittings and accessories) all as specified and as directed.
S & F 110 mm bore PVC (SWR) Soil, waste and vent pipes single socketed in any length with rubber ring joints fixed to walls all as specified and as directed.
S & F 75 mm bore PVC (SWR) soil, waste and vent pipes single socketed in any length with rubber ring joints fixed to walls all as specified all as specified and as directed.
Dismantling mild steel work of any description not otherwise provided for all as specified and as directed.
S & F Mild steel roof trusses (framed), trusses, purlins, crane gantries, rails and framings and heavy bracket framing (Beam, tee, angle, channel or flat sections) confirming to Fe 410-W including cleats, distance pieces etc all as specified and as directed.
Dismantling wall and ceiling boards (fibre, pulp, insulation etc.) any thickness, including cover fillets all as specified and as directed.
Providing & Fixing of Armstrong Mineral Fibre Acoustical Suspended Ceiling System with ANF (Board) edge tiles with Armstrong 24mm exposed grid. The tiles should have Humidity Resistance (RH) of 90%, NRC 0.5, Light Reflectance ≥85%, Thermal Conductivity k = 0.052 - 0.057 w/m K, Colour White, Fire Performance UK Class 0 / Class 1 (BS 476 pt - 6 &7) in module size of 600 x 600 x 15mm , suitable for Green Building application, with Recycled content of 34%.The tile shall be laid on Armstrong Prelude38 with 24 mm wide T - section flanges colour white having rotary stitching on all T sections i.e. the Main Runner, 1200 mm & 600 mm Cross Tees with a web height of 38mm and a load carrying capacity of 15.34Kgs/M2 & pull out strength of 100Kgs. The T Sections have a Galvanizing of 90 grams per M2 and need to be installed with Suspension system of Armstrong make or equivalent as approved by GE all as specified and as directed.
Taking down Chowkats or frames not exceeding 1.5 sq m each Without taking off shutters from the frames all as specified and as directed.
Taking down chowkat or frames exceeding 1.5 sq m but not exceeding 4 sq m each without taking of shutters from the frame and removing to store all as specified and directed.
S&F Powder coated aluminium window/ventilators shutter including frame, any type sliding or openable with frame, & other similar work etc. fabricated by using the JINDAL/HINDAL CO standard section including necessary arrangements to receive 4mm thick glass or wire mesh with aluminium channel beading & stainless steel screws including the cost of rubber gasket/rubber beading etc. complete including necessary handles, roller wheels, hinges etc complete all as specified and as directed. Note :- Weight of aluminium section shall be measured exclusive of all fittings fixtures, hinges, handle, bolts, rubber gasket/rubber beading and locking arrangements.
S&F Powder coated aluminium grill of design DG-104 pattern, made out of 10mm dia rod fixed with and including stranded aluminium frame of 'F' section of size 23.4x15.3x1.4 mm thick all as per manufacturer's instructions complete all as specified and as directed
M&L for forming jambs etc to openings including cuttings toothings and bondings into old work including facing and pointing to match existing work complete in cement mortar 1:4 all as specified and as directed
S&F Solid PVC Door frame of size 50 mm x 47 mm made out of 5 mm prelam colour PVC sheet reinforced with MS square tube all as specified and as directed.
S&F Factory made solid panel prelam PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded PVC ‘C’ channel having single side PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and both face prelam PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; panelling of prelam PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement all as specified and as directed.
S & F Soild PVC double Door frame of size 50 mm x 95 mm made out of 5 mm single side prelem PVC sheet reinforced with MS square tube all as specified and as directed.
S&F Factory made solid PVC moulded door designer shutter 30 mm thick comprising of 25 mm thick solid particle board core in centre core, with 2,4 or 6 raised panel design with 2 mm thick moulded prelam PVC sheet on both face all as specified and as directed
Dismantling old particle boards/plywood as in shelves boarding, any description, fixed in any position with nails all as specified and as directed.
S & F 18 mm thick single side prelaminated wood grain solid PVC sheet suitably fixed in shelves; Partitions and shelves of built-in cupboards, almirahs, book cases, toilet boxes, racks, pelmets and similar work with all fittings all as specified and as directed.
S & F 150 mm long aluminium, anodised, barrel tower bolts of extruded section all as specified and as directed.
S&F Stainless steel butt hinges medium weight of 100 mm size all as specified and as directed.
S & F 150 mm long extruded aluminium alloy handles, fabricated type, anodized all as specified and as directed.
S&F Aluminium alloy, anodised, sliding door bolt 250mm with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy all as specified and as directed.
S & F Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor with overall length of cover plate 140 mm all as specified and as directed.
S & F Aluminium alloy wire mesh, 0.45 mm dia of wire and average width of aperture 1.40 mm and fixed with stainless wire staples all as specified and as directed.
S & F in repairs 20 mm dia aluminium alloy anodised curtain rails with brackets all as specified and as directed.
S&F 4mm thick sheet glass ordinary quality exceeding 0.5 sqm each pane all as specified and as directed.
S&F in repairs aluminium (extruded section) body door closer hydraulically regulated designation No 3, universal type suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg complete all as specified and as directed.
Dismantling/Taking out existing hessain base felt of any other existing water proofing treatment from roof including cement plaster and exposing the top surface of RCC slab including removing dust, dirt and washing the roof and removing the dismantled debris to a distance exceeding 200 m but not exceeding 3000m spread and levelled all as specified and as directed.
M&L for preparation of surface with wire brush and remove loose particle & laitance, wash with clean water, damaged or hollow portion, sharp edges etc. must be cut and removed till the mother slab. Filling the cracks and damaged portion with polymer mortar and allow it to cure for 24 hrs. Apply two coats of acrylic polymer based flexible cementitious elastomeric (Dr Fixit new coat / Conipur M-800 of BASF / equivalent of Sika / Cico/ mc- bauchemie) membrane of about 1 to 1.5 mm dry film thickness over a coat of primer as per manufacturer's instructions over roof slab etc and as per manufacturer's specifications Note: Water proofing treatment shall be carried out through authorized applicator of manufacturer
M&L for providing 10mm thick plaster in cement mortar 1:4 mixed with 3% integral water proofing compound over roof top surface finished to even & smooth without using extra cement all as specified and as directed. Note :- Integral water proofing compound shall be measured and paid separately
Roughening surfaces of old concrete floor or concrete surfaces by picking, sweeping clean and washing down with water to remove dust, etc all as specified and as directed.
M&L for machine cut kota stone slab flooring 20-25 mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing laid over & including 20 mm thick screed bed in cement mortar 1:4 complete all as specified and directed.
M&L for kota stone slab 20-25 mm thick in riser of steps, skirting, dado and pillar laid over cement screed and jointed with grey cement slurry and pointed with white/coloured cement with admixture of pigment to match the shade of granite store including cutting, moulding and polishing etc complete but over 10 mm thick rendering over cement mortar 1:4 complete all as specified and as directed .
M&L for coloured heavy duty paving, chequered finish, cement concrete endura industrial tiles 12 to 15 mm thick (square /rectangular) textured series area of each tile exceeding 0.07 sq m not exceeding 0.18 sq m as in floors, treads and risers of steps fixed with grey cement and pigment laid over complete all as per manufacturer instructions and of design all as specified and as directed.
M&L for screed bed or bedding layer of mortar 15 mm thick cement plaster 1:4 for laying floor finished to receive floor tiles all as specified and as directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding but not backing, removing serviceable tiles to store and rubbish off the premises all as specified and as directed.
M & L for non - skid ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.11 sq m but not exceeding 0.18 sq m, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over & including 20 mm thick screed bed in cement mortar 1:4 complete all as specified and as directed.
M&L for coloured glazed ceramic tiles in vertical surfaces 350 x 250 x7 mm/ 450 x 300 x7 mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match over & including 10 mm thick backing coat in cement mortar 1:4 all as specified and as directed.
M&L for vitrified ceramic tiles designer and digital 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sq m, in floors laid over & including 15 mm thick screed in cement mortar 1:6, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of floor all as specified and as directed.
All as per Item No.52 here in before but as in skirting/dado but over 10 mm thick rendering over cement mortar 1:4 all as specified and as directed.
M&L for coloured & digital non skid ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exe 0.38 sq m, in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including screed bed or bedding layer of mortar 15mm thick in cement mortar 1:6 complete all as specified and as directed
All as per Item No.54 here in before but as in skirting/dado but over 10 mm thick rendering over cement mortar 1:4 all as specified and as directed.
Demolition of un-reinforced cement concrete of any description and in any position not otherwise specifically provided for all as specified and as directed.
M&L for 75 mm thick cement concrete type C2, 1:3:6 using 40 mm graded stone aggregate in plinth protections, finished even and smooth without using extra cement all as specified and as directed.
Dismantling water tanks of capacity exceeding 500 ltr but not exceeding 1000 ltrs and removing to store all as specified and as directed.
S&F 1000 ltrs Rotational moulded polyethylene water storage tanks (cylinderical, vertical with closed top) hoisted and fixed in position including 20mm bore PVC float valve all as specified and as directed
Taking up or down steel water tubing of 15 mm dia and connections including cleaning for refixing or removing to store as specified and as directed
Taking up or down steel water tubing of 20 mm dia and connections including cleaning for refixing or removing to store as specified and as directed
Taking up or down steel water tubing of 25 mm dia and connections including cleaning for refixing or removing to store as specified and as directed
Supplying and laying of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified of dia 20 mm as specified and as directed
Supplying and laying of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified of dia 25 mm as specified and as directed
Supplying and laying of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified of dia 32 mm as specified and as directed
S&F in repairs fancy type chromium plated 15 mm bore stop valve/angle cock cast copper alloy, screwed down high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions complete all as specified and as directed.
S&F in repairs wash basins 550x400mm vitreous china (flat back type) any size incl cutting for and pinning in end of brackets for erecting stand but exclusive of fixing of supply and waste pipe but including waste fittings all as specified and as directed.
S&F in repairs PVC valveless, syphonic action type flushing cistern, low level , white, with inlet ball valve, float and handle including brackets 10 litres capacity all as specified and as directed.
S&F in repairs vitreous china squatting pan , 'Orissa pattern, size 580x440 mm white, with integral foot rest excluding flushing cistern and flush pipe including connection to trap, to flushing pipe, anti-syphonage pipe, etc complete including making good to floor all as specified and as directed.
S&F in repairs vitreous china wash down water closet pan (Pedestal pattern) white complete including seat and cover, flush pipe including all joints complete all as specified and as directed.
S&F in repairs vitreous china half stall urinals, white complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, magnum urinal spreader, pointing around urinal back in cement; flush pipe, grating and Union for discharge pipe all as specified and as directed.
S&F PVC Connections 15mm size with PTMT nuts of length 600 mm all as specified and as directed.
S&F in PVC (SWR) floor trap 75 mm, plain with CP grating including joining and solvent cement all as specified and as directed.
S&F Bottle trap of PTMT having minimum water seal of 25mm .(Minimum weight 32mm-260gms) 32mm bore all as specified and as directed.
S&F in repairs 15mm bore, chromium plated bib taps cast copper alloy with crutch or butterfly handle screwed down for iron/PVC pipe complete all as specified and as directed.
S&F in repairs fancy type pillar taps, 15 mm dia, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe all as specified and as directed.
S&F in repairs tubular towel rail brass chromium plated , 20mm dia, 60cm long between flanges all as specified and as directed.
S&F in repairs brass chromium plated shower roses with or without swivel joints, any size, including fixing to steel pipe or union along with arm 225mm and flange all as specified and as directed.
S & F Glass shelf with Sheet Glass shelf assembly consisting of 5.5 mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60 cm long all as specified and as directed.
S&F in repairs Soap dish, vitreous china white/CP, approximate size 160x 160x90mm all as specified and as directed.
S & F 50 mm bore Low density polyethylene pipes (LDPE) of pressure rating 6 Kgf/ Sq. Cm., fixed complete to walls, ceilings or in floors etc all as specified and as directed.
Demolition of stone /boulder masonry, built in cement mortar including all quoins, arches, pillars, etc., but excluding ashlar facings, dressed stonework and precast concrete articles all as specified and as directed.
M&L for precast cement concrete 1:3:6 type C-1, using 20mm graded stone aggregate block masonry with solid blocks built in cement mortar 1:6 all as specified and as directed.
Taking down cement plastering at any description on brick or stone wall etc including raking out joints hacking for key scrubbing down with water etc and removal of debris and depositing where directed.
M&L for preparation of new plastered surfaces of ceiling and applying 3 mm thick wall care putty on ceiling and two coats of oil bound distemper over chalk whiting, preparatory to distempering all as specified and as directed. .
M&L for complete removal of existing treatment on ceiling and applying 3 mm thick wall care putty and two coats of oil bound distemper complete all as specified and as directed.
M&L for rendering 15 mm thick cement plaster on concrete solid block walls in two coats first coat of 10 mm in cement mortar 1:4 & 2nd coat of 5mm in cement mortar 1:4 mixed with integral water proofing compound finished to even & smooth without using extra cement all as specified and as directed. Note :- Integral water proofing compound shall be measured and paid separately.
Supply only water proofing compound all as specified and as directed.
M&L for preparation of old/new surface of wall and applying two coats of water proofing treatment by using araldite builder barrier coat or equivalent @ 5 Sqm per Ltr for first coat and 6 Sqm per Ltr for second coat (alongwith suitable pigments for colour as directed by Engr-in-Charge all as specified in manufacturer's instructions and to be applied through applicator of authorised manufaturer with 5 Years guarantee.
M&L for rendering 15 mm thick in cement mortar 1:6 on concrete solid block wall internal surface finished even and smooth without using extra cement all as specified and as directed.
M&L for preparation of new plastered or un-plastered surfaces and walls including cornices, pilasters etc and applying two coats of oil bound distemper over 3mm thick wall care putty complete all as specified and as directed.
M&L for complete removal of existing treatment on walls and applying two coats of oil bound distamper on walls over 3mm thick wall care putty all as specified and as directed
Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for all as specified and as directed.
M&L for mild steel deformed bars or TMT bars CRS 6mm to 8mm dia, cut to length, bent to shape required including cranking bending spirally & binding with and in including mild steel wire (annealed) not less than 0.9mm dia complete all as specified and as directed.
M&L for reinforced cement concrete Type A1, 1:1.5:3 using 20 mm graded stone aggregate for slabs suspended on walls, beams and columns, in floors, roofs, landings and in shelves and the like including necessary form work all as specified and as directed.
M&L for preparation of new steel surface and applying one coat of red oxide zinc chrome primer and two coats of Epoxy anticorrosive paint over 10 cm width or girth all as specified and as directed.
Schedule 'A' -Part II ( Internal Electrification Works)
Taking down unserviceable high bay luminaires/Flood light fitting from hanger up to 18 m height all as specified and as directed.
Taking down old unserviceable/perishable sub main wiring of any size/core/type from the ceiling of hanger complete with PVC /steel conduit/PVC casing capping including earth continuity conductor, junction boxes etc and making good the disturbed surfaces all as specified and as directed.
S&F LED High bay 200 W suitable for hangers / industrial application, integral industrial SMD LED with pressure die-cast aluminium housing, anodised aluminium reflector, complete with all accessories ,lumen efficiency > 120 lm/w , CRI > 85% ,THD < 15% UL certified. The luminaire should have 5 KV surge protection, PF > 0.95. The manufactures LOGO must be embossed/Engraved in the housing of the luminaire. Manufactures to provide LM80 from source manufacturer and should have adequate testing facilities approved by ministry of science (Govt of India) to provide LM 79 report complete all as specified and as directed Make- Cat Part No . BGHBM 200W LED XE of Bajaj or equivalent as per appendix 'B'
S&F LED Flood Light 200W suitable for Hangers / industrial application, with secondary optics with pressure die-cast aluminium housing, and heat sink in aluminium , complete with all accessories ,lumen efficiency > 120 lm/w , CRI > 85% ,THD < 15% UL certified. The luminaire should have 5 KV surge protection, PF > 0.95. The manufactures LOGO must be embossed/Engraved in the housing of the luminaire. Manufactures to provide LM80 from source manufacturer and should have adequate testing facilities approved by ministry of science (Govt of India) to provide LM 79 report complete all as specified and directed . Make- Cat Part No . BJFL 200W LED I of Bajaj or equivalent as per appendix 'B'
M & L for point wiring with 1.5 Sq mm (nominal area) FRLS PVC insulated unsheathed multi stranded copper conductor cable in and including PVC surface conduit 20 mm dia medium grade ISI marked including fittings and accessories with continues PVC insulated copper cable with copper conductor of same size as in phase/neutral/earth cable connecting to common earth dolly including (PVC / Wooden box of suitable size with laminated sheet cover of 3 mm thick for mounting swiches ,socket, regulator) for one light , fan point controlled by one way switch all as specified and directed .
All as per item No 102 here in before, but for 5 Amp socket point on the same board complete all as specified and as directed
All as per item No 102 here in before, but for 5 Amp socket point on the independent board complete all as specified and as directed
S & F in repairs modular switch single pole one way 6 A, 240 V complete all as specified and as directed
S&F in repairs ceiling rose 3 terminal 230 volts, PVC polycarbonate, isolated body completed all as specified and as directed.
S & F in repairs modular sockets 6A - 2/3 pin combined 2 module all as specified and as directed
M&L for point FRLS/LS wiring with cable size 2.5 Sq mm nominal area PVC insulated and unsheathed cable single core multi stranded, copper conductor in steel conduit for one 3 pin, 15 Amps socket out let on independent board and multi strand insulated copper earth continuity conductor of size 2.5 sq mm all as specified and as directed
S & F in repairs modular sockets 6A / 16A - 2/3 pin combined 2 module all as specified and as directed
Taking down Ceiling /Exhaust fan, ceiling cable end, dismantling blades and removing fan and blades to store all as specified and as directed.
M&L for painting of ceiling/exhaust fans complete, in situ with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust etc all as specified and as directed.
S & F in repairs LED panel 2' X 2' recess mounting luminaire suitable for armstrong/grid/ Pop ceiling complete with separate electronic driver & high brighteness SMD Leds complete all as specified and as directed. Make: Cat part No BZRSQL 24W XE NW of Bajaj or equivalent as per a\Appendix ‘B’.
S & F MCB TPN, 63 Amps, 415 volts all as specified and as directed
S & F MCB SP 6 to 32 Amps, 240 Volts all as specified and as directed
S & F MCB SPN 6 to 32 Amps, 240 Volts all as specified and as directed
S & F RCCB 4 Pole 30 mA 63 Amps all as specified and as directed
S & F Vertical MCB DBs VTPN 4 Way sheet steel, phospetised, powder coated with 200 Amps rated bas bar double door, 415 Volt all as specified and as directed. Make- Cat part No CSDBTPNVDD04 of C&S or equivalent as per Appendix ‘B’.
S & F MCB DB SPN 8 ways sheet steel enclosure, phospetised, powder coated with double door, 415 Volt all as specified and as directed. Make- Cat part No CSDBSPNFDD08 of C&S or equivalent as per Appendix ‘B’.
S&F in repair hanger obstruction light fitting Aviation yellow painted die-cast aluminium alloy housing, red coloured polycarbonate dome and accessories LED type suitable to 230 V AC protection weather proof IP66as per IS2147 sealed against water and dusts all as specified and as directed Make- Cat No BGAV 302 LED of Bajaj or equivalent as per Appendix ‘B’.
M & L for sub main wiring with 2 runs of FRLS PVC insulated & unsheathed multi stranded copper conductor of nominal cross sectional area 2.5 sq mm along with one run of FRLS PVC insulated & unsheathed copper conductor of nominal cross sectional area 2.5 sq mm as earth continuity conductor drawn through steel conduit as required size confirming to IS: 9537(Part-3), including accessories fixed on wall/ceiling all as directed including making good of disturbed surfaces area all as specified and as directed Note :- Three runs of cable and one run of PVC casing capping/conduit shall be measured as one unit
M & L for sub main wiring with 2 runs of FRLS PVC insulated & unsheathed multi stranded copper conductor of nominal cross sectional area 4.0 sq mm along with one run of FRLS PVC insulated & unsheathed copper conductor of nominal cross sectional area 4.0 sq mm as earth continuity conductor drawn through steel conduit as required size confirming to IS: 9537(Part-3), including accessories fixed on wall/ceiling all as directed including making good of disturbed surfaces area all as specified and as directed Note :- Three runs of cable and one run of PVC casing capping/conduit shall be measured as one unit
M & L for earthing complete with galvanized steel earth plate electrode of size 60cm x 60cm x 6mm thick, buried directly in ground vertically earth pit not less than 2.25 m deep below the ground level with top to edge of the plate n. less than 1.5 m below ground level connected to galvanized iron wire 4 mm as earthing lead by means of blots, nuts, check nut and washer of galvanized steel, including necessary earth work and excavation in any strata and PCC 1:3:6 type C2 chamber and RCC cover and light grade GI pipe 40 mm dia pipe of required length for protection of GI wire and water funnel and wire mesh with GI pipe medium grade 20mm dia etc complete all as per electrical plate No 3 of SSR part - I and all directed including connections and testing on completion all as specified and as directed
S & F DB mounted MCB type indicating lamp single phase Red/Yellow/Blue all as specified and as directed
S & F DB mounted MCB type indicating lamp Three phase Red+Yellow+Blue all as specified and as directed
S & F LED MS batten with decorative end cap complete with retrofit T8 glass tube light 20 W 230 V all as specified and as directed
S & F in repairs air Circulator heavy duty of 600 mm Sweep and having 1440 RPM all as specified and as directed
Schedule 'A' -Part III ( External Electrification Works)
Supply and lay cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 16 sq mm 4 core all as specified and as directed
Supply and lay cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 95 sq mm 3 1/2 core all as specified and as directed Notes for Item Nos 127 & 128 : Excavation, PCC cable cover and Sand for cushioning shall be measured and paid separately
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m deep in hard/dense soil getting out and levelling of bottom surface to required level for laying of UG cable erection of poles all as specified and as directed
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m deep in soft/disintegrated rock getting out and levelling of bottom surface to required level for laying of UG cable/ erection of poles all as specified and as directed
Excavation in trenches by cutting of road/ concrete/ bituminous/PCC hard standing getting out and levelling of bottom surface to required level for laying of pipe/cable including making good the existing surface with same finish to match the original finish all as specified and as directed
Returning filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25cm thick all as specified and as directed
Removing excavated material of soils from site to a distance not exceeding 50 m away and depositing where directed not exceeding 1.5 m from the starting point.
Supplying and filling in trenches clear M-sand for cushioning under ground cable 8 cm below and 15 cm above complete in level all as specified and as directed Note:Punned thickness of sand shall be measured and paid
Supplying & Laying precast concrete cable cover, class LV, type 1, flat, size 250mm x 150mm x 40 mm in trenches to protect under ground cable complete all as specified and as directed.
M & L for earthing complete with galvanized steel earth plate electrode of size 60cm x 60cm x 6mm thick, buried directly in ground vertically earth pit not less than 2.25 mtr deep below the ground level with top to edge of the plate n. less than 1.5 mtr below ground level connected to galvanized iron strip 25 x 4mm as earthing lead by means of blots, nuts, check nut and washer of galvanized steel, including necessary earth work and excavation in any strata and PCC 1:3:6 type C2 chamber and RCC cover and light grade GI pipe 40 mm dia pipe of required length for protection of GI wire and water funnel and wire mesh with GI pipe medium grade 20mm dia etc complete all as per electrical plate No 3 of SSR part - I and all directed including connections and testing on completion all as specified and as directed.
Supply install, test and commission cubicle type CPRI approved LT feeder pillar box mounted on pedestal factory made, totally enclosed, dust & vermin proof (protection class IP 54), (front opening) with proper locking arrangement made of MS angle iron frame size of 40mmx40mmx6mm and CRCA sheet of 3.15 mm thick duly painted with two coats of synthetic enamel paint over a coat of red oxide primer. The panel shall be suitable for 415 volts, 50 Hz 3 phase 4 wire system and shall be complete with 600 Amps capacity copper bus bar with suitable size of PVC insulated copper conductor for internal wiring, thimbles glands and shall be complete all as specified as directed with the following accessories. The cost of the PCC pedestal is deemed to be included in the quoted rate of above item. The panel will comprise of the following :-
M/S jvsr constructions
M/S G.N.POWAR
M/S P S BABU
M/s. R.S. LAWANDE
M/s J.D. DESAI
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .