| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.0 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹13.9 L+₹93,658 (7.20%)Rejected-Finance | L2 | Rejected-Finance Higher Bidder | |
| 3 | L3₹14.4 L+₹1.4 L (10.9%)Rejected-Finance G 2 BIDHAN NAGAR P O MIDNAPUR P S KOTWALI DIST PASCHIM MEDINIPUR PIN 721101 | MIDNAPUR | PASCHIM MEDINIPUR | WEST BENGAL | 721101 | L3 | Rejected-Finance Higher Bidder |
| Sl No | Description | Qty | Unit | M S KAMAL SHAW L2 | ELCON ENGINEERS L1 | M/S JOGMAYA ENTERPRISE L3 |
|---|---|---|---|---|---|---|
| 1.00 | Supply & fixing of Over Current, Short Circuit & Earth Fault Relay in place of damaged one in HT gear with proper EI connection by skilled person of MMC Substation as per direction of EIC. (Make-C&S electric Limited- IRI-PRO-3I-EI) | 1 | Each | 16,000 ₹16,000 | 15,000 ₹15,000 Lowest | 17,000 ₹17,000 |
| 2.00 | Modification of Existing Sub Station Panel:
Making necessary arrangement for existing two panel combind for catter load of all out going by introducing bus coupler and interlocking arrangement (Both Electrical & mechanical), changing existing buscoupler, ACB position, making link between two part bus bar of one panel etc. as directed by the EIC. Necessary Bus link of two separate panel in suitable size MS enclosure to be provided. (N.B.-Bidder shall quote rate after site visit and consultation with EIC. Existing two panel bus bar alignment are different.) | 1 | Job | 2,10,200 ₹2,10,200 | 1,90,000 ₹1,90,000 Lowest | 2,20,000 ₹2,20,000 |
| 3.00 | S & D of Fire extinguisher with an ABC rating of 6 kg each for fire sefty purpose at MMC Sub Station as per direction of EIC. | 8 | Each | 4,800 ₹38,400 | 4,280 ₹34,240 Lowest | 5,000 ₹40,000 |
| 4.00Charges for Shifting the followings running cables from one panel to other panel with his own tools and trackles as per direction of EIC. | ||||||
| 4.01 | (i) 4 core 185 sqmm | 4 | Each | 550 ₹2,200 | 500 ₹2,000 Lowest | 600 ₹2,400 |
| 4.02 | (ii) 4 core 150 sqmm | 4 | Each | 550 ₹2,200 | 500 ₹2,000 Lowest | 550 ₹2,200 |
| 5.00Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC existing armoured cables as below : | ||||||
| 5.01 | a) 4 core 300 sqmm | 2 | Each | 586 ₹1,172 | 531 ₹1,062 Lowest | 586 ₹1,172 |
| 5.02 | b) 4 core 185 sqmm | 4 | Each | 463 ₹1,852 | 403 ₹1,612 Lowest | 463 ₹1,852 |
| 5.03 | c) 4 core 150 sqmm | 4 | Each | 422 ₹1,688 | 366 ₹1,464 Lowest | 580 ₹2,320 |
Tender Value
Refer Docs
EMD Value
₹26,860
Closing Date
13 Mar 2024, 1:00 pmClosed
Executive Engineer Paschim Med. Elecl. Div. PWDte.
Office of the Executive Engineer, Paschim Medinipur Electrical Division, P.W.Dte., Midnapore, Paschim Medinipur.
Strengthening of Electrical Distribution capacity of Electrical Sub Station of MMC, Paschim Medinipur.
2024_WBPWD_670958_1
WBPWD/EE/PMED/NIQ-34/e-Q /2023-2024
Open Tender
ELECTRICAL WORKS ORG
Item Rate
30 days
Midnapore Medical College and Hospital.
Please refer Tender documents.
3 documents required · 3 mandatory
₹26,860
Off. of the EE, Pas. Mid. Elec. Divn. PWDte.
12 Sept 2025
20 Feb 2024
15 Mar 2024
20 Feb 2024
13 Mar 2024
28 Feb 2024
27 Feb 2024
Amount
Supply & fixing of Over Current, Short Circuit & Earth Fault Relay in place of damaged one in HT gear with proper EI connection by skilled person of MMC Substation as per direction of EIC. (Make-C&S electric Limited- IRI-PRO-3I-EI)
Modification of Existing Sub Station Panel: Making necessary arrangement for existing two panel combind for catter load of all out going by introducing bus coupler and interlocking arrangement (Both Electrical & mechanical), changing existing buscoupler, ACB position, making link between two part bus bar of one panel etc. as directed by the EIC. Necessary Bus link of two separate panel in suitable size MS enclosure to be provided. (N.B.-Bidder shall quote rate after site visit and consultation with EIC. Existing two panel bus bar alignment are different.)
S & D of Fire extinguisher with an ABC rating of 6 kg each for fire sefty purpose at MMC Sub Station as per direction of EIC.
Charges for Shifting the followings running cables from one panel to other panel with his own tools and trackles as per direction of EIC.
(i) 4 core 185 sqmm
(ii) 4 core 150 sqmm
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC existing armoured cables as below :
a) 4 core 300 sqmm
b) 4 core 185 sqmm
c) 4 core 150 sqmm
Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials :
a) 4 core 300 sqmm
b) 4 core 185 sqmm
c) 4 core 150 sqmm
Supply & delivery of 4 core 300 sqmm 1.1 KV grade, XLPE insulated as per IS 7098 (part-1) 1988 armoured sheathed Aluminium conductor cable as mentioned below. (Make- Polycab/ Havells/ Gloster/ RR Kabel)
Laying of one No. cable above 185 sqmm in underground trench 460mm wide x 760mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per Mtr. including filling the space between the bricks and cable and also the trenchwith shifted soil, leveling up and restoring surface duly rammed
Laying of one cable above 150 sqmm and upto 300 sqmm through existing covered masonry trench incl. taking out RC covers, setting them in order, mending good the damages filling the trench with fine dry sand incl. supplying sand
Laying only Cable above 50 sqmm but not exceeding 400sqmm through existing RCC/ Hume/GI Pipe/open masonary trench for single, 2, 3, 3½ and 4 core
Laying of above 50 sqmm but not exceeding 400sqmm through/on existing Cable Tray/ Angle iron frame and binding with suitable size GI wire.
Charges for cuttings of Pitch road & PCC road as per GS with Co. Own equipment for fixing of GI protection pipe for cable crossing and mending good damages to original finish as per direction of EIC.
Supplying & fixing 100mm dia medium gauge GI Pipe ( ISI-Medium) Protection with necessary fittings and jointing metarials as required
Charges for connecting the I/C & O/G to the Busbar with Supplying the suitable size copper cable ( approved Make) & suitable copper socket, for 400A-1 no, 200A-3 nos, 160A-1 no M/S with B/B of feeder piller no. #9 and for 400A-1 no, 200A-2 nos with B/B of feeder piller no. #8.
S & Providing on hire basis 01 nos. 415 V. 500 KVA 50 Hz silent DG Set with DG Operator round the clock, without diesel
S & Providing of Diesel oil (500 KVA @45 ltr. Per hours ( 26 hour x 45 ltr)
M S KAMAL SHAW
M/S JOGMAYA ENTERPRISE
stage.html
html • 0.05 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .