Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.0 LAccepted-AOC | L1 | Accepted-AOC Awarded | |
| 2 | L2₹27.6 L+₹59,937.40 (2.22%)Rejected-Finance | L2 | Rejected-Finance Other Than L1 | |
| 3 | L3₹29.5 L+₹2.5 L (9.30%)Rejected-Finance | L3 | Rejected-Finance Other Than L1 | |
| 4 | L4₹29.5 L+₹2.5 L (9.34%)Rejected-Finance | L4 | Rejected-Finance Other Than L1 | |
| 5 | L5₹29.7 L+₹2.7 L (10.2%)Rejected-Finance | L5 | Rejected-Finance Other Than L1 |
Tender Value
₹36.0 L
EMD Value
₹71,900
Closing Date
25 Nov 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE I KANPUR
GE I KANPUR Cariappa Road Kanpur 208004
SPECIAL REPAIR TO BLDG NO P 11 ASC SUPPLY DEPOT KANPUR
2021_MES_484072_1
GE(I)/KAN/T-49 OF 2021-22
Open Tender
Civil Works
Item Rate
180 days
Kanpur Cantt
Class D category a i
7 documents required · 7 mandatory
₹500
GE I KANPUR
₹71,900
Yes
29 Dec 2021
27 Oct 2021
2 Dec 2021
27 Oct 2021
25 Nov 2021
19 Nov 2021
60 days
Amount
Taking down cement plaster on bricks including raking out joints hacking for key scrubbing down with water etc.complete all as specified.
Demolition of unreinforcement cement concrete of any description and in position not otherwise specifically provided for complete all as specified and directed
Demolition of plain cement concrete in ground floor and pavings not exc 15cm thickness below or above ground level complete all as specified and directed
Demolition of brick work of any description and in any position built in cement mortar including quoins arches and pillars complete all as specified.
M&L for brick work with fly ash old size bricks, straight or curved on plan exc 6m mean radius built in cement mortar 1:4 for manholes, drains, septic tanks, soak wells etc. complete all as specified and directed.
M&L for PCC 1:2:4 type B-0 using 12.5mm graded stone aggregate as in copings, filling for fixing of hold fast etc including necessary formwork etc.
M & L 15mm thick rendering in cement mortar 1:6 on brick or concrete surfaces of wall finished fair and even complete all as specified.
M & L 15mm thick rendering in cement mortar 1:4 on brick or concrete surfaces, mixed with water proofing compound as per manufacturer's instructions, surfaces finished fair and even complete all as specified and directed by Engineer-In-Charge. Note:- WPC measured and paid separately.
Supply only integral water proofing compound. ISI Marked.
M&L 75 mm thick Cement concrete type D 2, 1:4:8 (using 40 mm graded crushed stone aggregate) as in sub base complete all as specified and as directed.
M&L 75 mm thick PCC (1:3:6) type C1(using 20 mm graded stone aggregate) as in plinth protection and paving laid in alternate bays finished finish even and smooth wihtout using extra cement complete all as specified and as directed
Dismantling floor hearth or wall tiling including cement mortar bedding (but not backing) complete all as specified.
M&L for glazed ceramic tiles coloured, joint free in vertical surface 300X 450X 7mm thick mm thick as on walls over and incl 10mm thick rendering in cement mortar (1:4) and jointing in neet slurry and pointing in coloured cement to match the inside of tiles all complete as specified and directed.
Demolition of stone slabs and tiles of any description or thickness in floors, approns etc laid, bedded and pointed in any mortar. (Note : Debris obtained from demolition will be dispossed off as directed)
M&L Machine cut kota stone slab flooring 18-20mm thick over cement screed base laid 15 mm thick screed bed in CM 1:6 and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified.
M&L Machine cut kota stone slab 18-20mm thick in riser of steps,skirting ,dado and pillar laid over 10mm thick rendering of cement mortar 1:4 and jointed with grey cement slurry mixed with pigment to match the shade of the slab complete all as specified.
M&L for machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60mm thickness , M-35 grade, set, jointed over 25 mm thick sand cushoning all as directed by Engineer-in-Charge.
M&L hardcore of broken stone or boulder of gauge n exc 63 mm , deposited spreaded , levelled in layers n exc 15 cm thick watered and rammed to true surface all as specified.
M & L Providing precast cement concrete 1:2:4, Type B1 (Using 20mm graded stone aggregate) as in kerb stone etc set in CM (1:4) complete all as specified.
Dismantling of CGI & PGI sheet in roof covering complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and as directed.
M&L Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc conforming to Fe 410 W (Gde-E-250) quality A complete all as specified and as directed.
S&F Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes with riveted, bolted or welded attachment etc incl mild steel screw bolts (machine made) with hexagonal or square heads at one end & washers as reqd conforming to Fe 410W .Gde-E-250, quality-A.
S & F regular modified Polyester colour coated galvanized steel rib profile sheet (TCT) 0.50mm thick E42 (inclusive of protective coating ) overall width 1060mm and total mass coating of 120 gms/sqm on both sides as per IS-14246:95 (JIS:3312 polyester coating 30-40 micron) as in roof etc fixed etc fixed to iron /wooden members with self drilling zinkallum coated metal screws having cap with rubber washers more than 3.00sqm patches as required in shapes complete all as specified and directed. Make: (a) Lloyd Insulation (b) Tata bluescope steel building solutions Ltd. (c) Prestar Infrastructure Project Ltd (d) Colour Roof India Ltd.(CRIL) (e) M/s Matco Roof PvtLltd. (f) Ispat Industries Ltd (JSW) (g) Everest Industries
S & F plain regular modified Polyester colour coated galvanized steel plain sheet (TCT) 0.50mm thick having tensile strength of 550 Mpa as in ridge, valley gurtter, drip and straight flashing fixed with self tapping screws of reqd size and dia with head having matching colour PVC cap / painted as of sheet total mass coating 150 gms/sqm (both side) in roofing complete all as specified and directed. Make: (a) Lloyd Insulation (b) Tata bluescope steel building solutions Ltd. (c) Prestar Infrastructure Project Ltd (d) Colour Roof India Ltd.(CRIL) (e) M/s Matco Roof PvtLltd. (f) Ispat Industries Ltd(JSW) (g) Everest Industries
S&F wind ties for roof including securing bolts as directed, including all necessary drilling, bolting or riveting, etc. and similar work conforming to Fe-290 Gde E-165 complete all as specified and as directed.
M&L for PCC type B0 (1:2:4 using 12.5mm graded stone aggregate) as in roof kerb, benching/ padding over roof surface including chamfered on eges etc complete all as directed.
Taking down chowkats without taking off shutter from chowkats area n.exc 1.5 Sqm each complete all as specified.
Taking down chowkhat or frame with shutter (without taking off shutter from the frame) area exc 1.5 Sqm and not exc 4 Sqm each complete all as specified.
M&L 2nd class HW as in plain , solid, straight chowkhats and frames , wrought , framed , rebated on the solid, rounded or chamfered, put together with glue pinned joints complete all as specified
Dismantling of unframed work timber scantlings 40 sq. cm and over in section, in any position
M&L Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging also fastening and fixing, conforming to Fe 410 W (Gde-E-250) quality A complete all as specified and as directed.
S & F hold fast of flat iron 25 x 3 mm.
S & F 35 mm thick factory made panelled shutter (two panel) with lock rail and panel of 9 mm B.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated complete all as specified.
S&F Joist, channel, angle, or tee sections fixed independentaly, without connecting plates, etc. (cut to ordinary lengths i.e. within 20mm of the length indicated) conf to Fe-410-w or E -250 quality A complete all as specified and directed.
S & F expanded metal of wt n exc 4 kg per Sqm, cut to length, bent to shape required and tying with and including annealed mild steel wire not less than 0.9mm dia or fixing with galvanised steel staples supplied and fixed complete to wood or steel members. complete all as specified and directed.
S&F factory made steel tubular window with side hung shutters including box type hinges with steel handle and steel peg stay complete with glazing bars dovetailed or welded etc complete all as specifed and as per HQ CELZ Lucknow Drg no LZ/C-TD/130 sheet 1/4 to 4/4 and as directed by Engineer in Charge. Note : 3mm plain sheet glass panes shall be deemed to be included in this item.
S&F factory made steel tubular ventilator with side hung shutter including hinges steel peg stay, complete complete all as specifed as per HQ CELZ Lucknow Drg no LZ/C-TD/130 sheet 1/4 to 4/4 and as directed by Engineer in Charge. Note: 3mm frosted / pin headed sheet glass panes shall be deemed to be included in this item.
M&L for framed work such as grills, gratings etc, with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars, cooler stands etc conforming to Fe-290 Gde-E-165 complete all as specified..
S & F 100mm size mild steel, butt hinges, medium weight, cold rolled and fixed with mild steel screws as specified.
S&F 200mm long barrel tower bolt of aluminium extruded section complete all as specified and directed.
S&F 150mm long handle of aluminium extruded section fabricated anodized type complete all as specified directed.
S&F 300mm long aluminium alloy, anodized sliding door bolt with hasp staple (bolt type) and fixing clips of sheet cast or extruded section & fixing bolts and sliding bolts of extruded section complete all as specified and directed.
M&L for preparation of new plastered surfaces and applying three coats of white wash as on wall surfaces complete all as specified and directed
M&L for preparation of old plastered surfaces and applying two coat of white wash as on wall including removing/ brooming down or scraping down loose dirt by steel wire brushes etc complete all as specified.
M&L for preparation of new plastered surfaces and applying two coat of cement based paint of approved shade on plastered surfaces of wall complete all as specified and directed.
M&L for complete removal of existing treatment from surface of walls and preparation of old plastered surfaces and applying two coat of cement based paint of approved shade on plastered surfaces of wall complete all as specified and directed.
M&L for preparation of new steel surfaces and applying two coats of synthetic enamel paint over a coat of red oxide & over 10cm width or girth complete all as specified.
M&L for preparation of new steel surfaces and applying two coats of synthetic enamel paint over a coat of red oxide n.exc 10cm width or girth complete all as specified.
M&L for preparation of new wooden surfaces width or girth exc 10 cm and applying two coat of synthetic enamel paint over a coat of pink primer complete all as specified .
M & L preparation of old steel surfaces of any description over 10 cm width or girth and apply two coats of synthetic enamel paint complete over truss purlin etc all as specified and directed.
S & F 3 mm thick Polycobonate sheet corrugated sheet with corrugation same as profile sheet as in roof covering/cladding to wall, fixed with self tapping screws as specified
S & F 3mm thick Polycobonate sheet corrugated sheet with corrugation same as profile sheet and fixing arrangement of sifdriven air ventilator in middle portion as in roof covering/cladding to wall, fixed with self tapping screws as specified
Taking down of old unserviceable rolling shutter of area exc 7.0 Sqm but not 10.0 Sqm each complete all as directed.
S&F steel rolling shutters 1.25mm thick, with out ball bearing, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer; erected in position as indicated, push pull or manual type complete all as specified and directed
S&F steel rolling shutters Safety lever locks mild stee lwith 4 levers for rolling shutters
S&F Ball bearing for rolling shutters
EnM Schedule
Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting, bell, bell push etc and making good disturbed surfaces of walls, floor to match with existing specification complete and all as specified and directed.
M&L for point wiring for one light / fan / bell point controlled by one switch with PVC (FRLS) insulated and unsheathed cable 1.5 Sqmm (Nominal area) multi-stranded copper conductor single core with proper colour coding including PVC conduit medium grade of 20mm dia concealed in walls and surface on ceiling with and including pressed steel concealed terminal boxes of appropriate size and top cover 3 mm thick of plastic laminated sheet ISI marked of desired colour of make : Hylam, painting terminal boxes inside and outside with a coat red oxidé primer complete with all accessories with and including 1.5 Sqmm PVC insulated and unsheathed green colour multi-stranded copper conductor cable to common earth and connected to earth dolly complete all as specified and directed. Note: Cutting chases in walls required for concealed conduit wiring shall be finished with cement mortar 1:4 and, surface shall be matched with existing surface by using putty, plaster of paris etc. and applying finishing coat of existing treatment shall be deemed to be included in the unit rate quoted by the contractor.
One light / fan / bell / exhaust fan point controlled by one switch.
One 3 Pin socket outlet 5 Amps on Independent board.
One 3 Pin socket outlet 5 Amps on same board.
All as per item No 60 here in before but for point wiring with 2.5 Sqmm (Nominal area) FRLS, PVC insulated and unsheathed copper conductor multi-stranded single core cable including green colour earth wire of size 1.50 Sqmm FRLS, PVC insulated and unsheathed copper conductor multi stranded single core cable for one 3 pin, 15 Amps socket outlet independent point complete all as specified and directed.
S&F switch piano flush type 5/6 Amps single pole one way complete all as specified and directed.
S&F switch piano flush type 15/16 Amps 240 Volts single pole one way complete all as specified and directed.
S&F socket outlet flush type, 5 pin 6 Amps, 240 Volts complete all as specified and directed.
S&F socket outlet 2 in 1, 6 pin 5 & 15 Amps, 240 Volts complete all as specified and directed.
S&F ceiling rose surface bakelite of three terminals 240 Volts complete all as specified and directed.
M&L for submain wiring with two single core 4 Sqmm copper conductor PVC insulated and unsheathed multi-stranded cable (FRLS) including PVC conduit medium grade of 25 mm dia, concealed in walls for sub main connection and 4 Sqmm PVC insulated and unsheathed multi-stranded green colour copper conductor cable (FRLS) as an earth wire to common earth and connected to earth dolly and including PVC conduit medium grade of 25mm dia concealed in walls and surface on ceiling complete all as specified and directed. Note: Cutting chases in walls required for concealed conduit wiring shall be finished with cement mortar 1:4 and, surface shall be matched with existing surface by using putty, plaster of paris etc. and applying finishing coat of existing treatment shall be deemed to be included in the unit rate quoted by the contractor.
S&F in replacement of old light fitting with LED tube light fitting high efficiency extruded aluminium housing linear batten 20/22 watt (6500K) fixed on wall/ceiling complete with all accessories along with LED tube rod 20/22 watt and provision of flexible 1.50 Sqmm copper conductor cable from ceiling rose to light fitting and other fixing arrangement as required at site complete all as specified and directed. Make : Wipro / Havells / Phillips / Bajaj Note : Contractor will submit guarantee/warranty certificate from manufacturer.
S&F in replacement of LED wall security light 25 watt, pressure die- cost aluminium IP-66 road way luminaries with high power LED as light source with acrylic cover with suitable size bracket fixed with clamps, nut bolt, washer and provision of three core flexible of 1.50 Sqmm copper conductor cable from ceiling rose to light fitting complete all as directed Make: Havells cat part no SL25WLED 757SASYTOPCMP/ WIPRO cat part no LR02-291-xxx-57-xx/ C&S cat part no INDUS-E/25W LTESSE25WLED/Bajaj cat part no BCLST25WLEDIV2 or equivalent in Philips/CG. Note : Contractor will submit guarantee/warranty certificate from manufacturer.
S&F sheet metal enclosure double door factory made MCB distribution board Single pole and neutral 240 Volts, 8 way with neutral and earth bus bar having IP-43, IK-09 protection and double door metal concealed/flush to wall surface including making connections with thimbles as required complete all as specified and directed. Make : Schneider / L & T / Legrand/C&S/ Indo Asian/Havells
M&L for MCB single pole, 240 volts 6 to 32 amps, with rupturing capacity 10 KA using thimbles of required size. Make : Schneider / L & T / Legrand/Indo Asian/C&S/Havells/ABB
M&L MCB SPN, 240 volts 32 to 63 amps,with rupturing capacity 10 KA using thimbles of required size. Make : Schneider / L & T / Legrand/Indo Asian/C&S/Havells/ABB
M & L for earthing with galvanised steel earth plate electrode 600 x 600 x 6mm thick buried directly in the ground (earth pit not less than 2.25 metre deep below normal ground level) with top edge of plate not less than 1.5 metre below the ground level, connected to galvanised earth lead wire 4 mm dia by means of nuts, bolts, check nuts and washers of galvanised or steel all as specified or shown in electrical plate of SSR (Part-l) including necessary excavation, earth work, GI pipe 15 mm dia light grade for protection of galvanised iron earthing wire, GI pipe 20 mm dia light grade watering pipe etc. including concrete chamber of PCC 1:2:4 type B-2 (using 40mm graded stone aggregate), copping in PCC 1:3:6 type C-1 (using 20mm graded stone aggregate), internal surface of concrete chamber shall be plastered with 12 mm thick cement mortar 1:4 and 50 mm thick RCC cover in pre-cast cement concrete 1:2:4 type B-1 (using 20mm graded stone aggregate) duly reinforced with 8 mm dia TMT bar @ 80 mm c/c both ways and charcoal dust, common salt etc. including testing after completion complete all as specified and directed.
Disconnecting electrically and taking out old unseviceable LT Under Ground Cable any type and size completion complete all as specified and directed.
Supply and laying XLPE insulated heavy duty electric cable with aluminium conductor 1100 volts grade, cross sectional area 10 Sqmm, 2 core in trenches or fixing to wall/pole or passing through pipe including making good disturbed wall surfaces/ flooring/tilling to match with existing specification complete all as specified and directed.
Excavation in trenches in soft/loose soil not exc 1.5 mtr in width and not exc 1.5 mtr in depth and getting out for laying of cables and for rerouting of cables etc complete all as specified and directed.
Returning, filling in including spreading, levelling, watering and well ramming in layers not exc 25cm each complete all as specified and directed.
Removing excavated material to a distance not exceeding 50 meters and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and directed.
M&L for sand filling and cushioning to underground cables, 8 cm thick before laying the cable and 15 cm thick after laying, stretching and testing the cable and for under floor complete all as specified and directed. Note : Only punned thickness shall be measurement and paid.
Supply and laying sub class 'B' bricks old size 230mm x 115mm 75mm complete all as specified and directed.
murty construction company
M/s DKS Engineering Works
M/s S K ARORA
ARORA BROTHERS
Allied Builders And Engineers
M/s R.V. Constructions
JOG CONSTRUCTION
RAJAT TRADERS
M/S SDS Construction Co.
Talson Builders
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .