Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.7 LAccepted-AOC | L1 | Accepted-AOC lowest bidder | |
| 2 | L2₹26.0 L+₹1.2 L (5.00%)Rejected-AOC | L2 | Rejected-AOC other than lowest bidder | |
| 3 | L3₹28.4 L+₹3.6 L (14.6%)Rejected-AOC | L3 | Rejected-AOC other than lowest bidder | |
| 4 | L4₹30.2 L+₹5.4 L (21.9%)Rejected-AOC MAIN BAZAR SURANKOTE DISTT POONCH 185121 J K | SURANKOTE | POONCH | J K | 185121 | L4 | Rejected-AOC other than lowest bidder | |
| 5 | Rejected-Technical | - | Rejected-Technical Not enlisted in required category |
Tender Value
₹28 L
EMD Value
₹56,000
Closing Date
9 May 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE
HQ CWE Rajouri PIN-900129 C/o 56 APO
PROVN OF EXTERNAL ELECTRIC SUPPLY AT KDL-490 AT HAMIRPUR UNDER GE 881 EWS
2022_MES_517569_1
CANO-CWE/PNH-03/2022-23
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Hamirpur AOR of GE 881 EWS
Class D Category b(ii)
9 documents required · 9 mandatory
₹500
GE 881 EWS
₹56,000
Yes
15 Jun 2022
11 Apr 2022
16 May 2022
11 Apr 2022
9 May 2022
25 Apr 2022
60 days
Amount
Supply, installation commissioning and testing of 25 KVA transformer, step-down 11/0.433 KVA, outdoor type,powder coated, copper wound, 3 phase, 4 wire 50 cycles per second, oil immersed naturally cooled with external cooling tubes, core type delta connected on primary (HT Side) and star connected on secondary (LT Side) having tapping +0%,2.5%,5%,7.5%,10% to be changed by means of hand including first filling of oil of dielectric strength not less than 40 KV,all standard operating complete with standard fittings and accessories such as breather unit , drain out valve,roller,conservator oil tank of suitable capacity with level indicator , exhaust vent ,temperature gauge,pressure gauge etc and mounting complete all as specified in IS 1180 (Part-I) level-II and minimum 4 star rating BEE Specification capacity of 25 KVA all as specified and directed.
M&L for Construction of platform suitable for 25 KVA Transformer / Voltage stabilizer of size 2.0m x 2.0m x 0.6 m (Plateform shall be made out of brick masonary One feet below ground level and one feet above ground level hollow space and to filled by PCC 1:3:6 type C-2 , watered and well rammed with 100 mm thick cement concrete 1:2:4 type B-2 as in floor of platform, 15mm thick plastering in CM 1:4, complete all as specified and directed.
Supply and fix Voltage stabilizer outdoor type for automatic operation, three phase for unbalanced load naturally oil cooled, outdoor type & designed for input variation between 210 V to 480 V with output voltage stabilized at 415 with accuracy ± 2.5% and speed of correction 8 Volts per second and of capacity 25 KVAcomplete all as specified and directed. Note:- Voltage stabilizer shall be copper wounded.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 95 sq mm 3.5 core all as specified and directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50 sq mm 3.5 core all as specified and directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sq mm 4 core all as specified and directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sq mm 2 core all as specified and directed.
Switch air break gang operated triple pole mechanically operated from ground level mounted on 12 insulators, outdoor type suitable for vertical installation single break provided with locking arrangement for operating handle including seven levers “Navtal” lock consisting of mid steel channel 75 mm, HT post Top insulator copper alloy high pressure assembly with drop out expulsion fuses for phases, operating rod of 20mm dia medium grade GI pipe complete conforming to IS-1018 of 1972 with continuous current rating 400 Amp, 11000 volts grade complete all as specified and as directed.
Lightning arresters expulsion type complete with all fittings, transmission class, dies-charge capacity 65 kilo amp for working pressure 11000 Volts all as specified and directed.
Cross arms, bracings, supports, clamps (including stay clamps, clamps for fixing GI tubes for passing through of cables) and back plates fabricated out of standard steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts in any shape or size as directed and inclusive of providing two coats of aluminium paint over a coat of primer after preparation of steel surfaces complete.
Steel tubular swaged pole complete with MS base plate 6mm thick of size 300mm x 300mm, finial taper plug, bolts, nuts and washers and screws, type 410-SP 55 (11 m long) including drilling of holes of required size of nuts for fixing of cross arms, painting with a coat of red oxide zinc chrome primer and two coats of aluminium paint of exposed surfaces and two coats of black bituminous paint for portion embedded in concrete, painting five black/ white bands at lower portion of pole each of 300mm height at 300mm spacing, complete all as specified and as directed.
M&L for disc type insulator, porcelain, vitreous 145mm high and 225mm dia ball and socket type, white, brown or green, single disc assembly for tension with tension clamps for conductors, working pressure 11000 volts, complete all as specified and as directed.
Supply and fixing in pin type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut 150mm height, 150mm dia for working pressure 11000 Volts grade of HT line complete all as specified and directed.
M& L for stay assembly complete with accessories i.e stay plate 300mm x 300mm x 6mm, galvanized thimbles,bow stay rode of 20mm dia, G.I. loop type insulators, vitreous porcelain, white brown or green of large size with overall dimensions 90mm x 140mm, clearance of hole 25.5mm, etc and all other accessories as shown in electrical plate No.1 on Ser Page No.19-47 of MES Schedule Part-I complete. Note : Stay clamp, stay wire, excavation and earth work and concrete for stay pit shall be measured and paid for separately.
Stay wire stranded 7/3.15mm including stay clamp and fixing arrangement complete all as specified
Supply, stringing, streaching and binding with insulator, ACSR conductor (Weasel /ferret/Mink or any type as approved by GE) on HT/LT Poles including providing of necessary jumpers, binding wire etc, connecting all existing incoming and out going connections all as specified & directed.
Supplying laying, commissioning and testing XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 11000 volts grade (earthed) of cross sectional area 95 sq mm 3 core complete all as specified and as directed.
Cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination Heat Shrinkable joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 Sqmm to 95 Sqmm all as specified and directed.
Supply and laying GI tubes light grade ISI marked , galvanized, 80mm bore laid in trenches or under floor or fixed with poles/walls for protection of electric cable, complete all as specified & directed .
Anti climbing devices comprising 2.24mm dia galvanised steel 2-strand barbed wire with 2.00mm dia barbs wrapped spirally round poles, to a length of 0.5 to 1.0 metre clamped and properly secured or as ordered (clamps measured separately) and inclusive of providing two coats of aluminium paint over a coat of primer after preparation of steel surfaces complete all as specified & directed .
Cradles, hexagonal/rectangular, fabricated with galvanised steel wire 3.15 or 4mm dia complete all as specified and directed .
Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for HT, 25x20cm size Complete all as specified and directed.
Earthing for poles and other machinery/eqpt in repair using copper strip as earth lead and copper earth plate electrode 60x60 cm x3.15 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate is not less than 1.5 mtr below normal ground level connected to copper strip 20x3mm with GI pipe, nuts, bolts and washers complete upto and including test point made out of 40x3mm GI flat, PCC pit of required size in PCC 1:2:4 type B1 and RCC cover with frame, charcoal, common salt 15cm at round the earth plate watering pipe 20mm med grade/galvanized and 40mm dia GI pipe light grade for GI strip protectetion, funnel with wire mesh including testing on completion, complete all as specified and directed as shown in electrical plate No 3 of SSR Part-I 2009. (Note: The unit rate includes earth strip and protection pipe upto (maximum 7.5 metre from earth plate) earth point/test point.
Earthing for poles and other machinery/eqpt in repair using GI strip as earth lead and MS galvanized steel earth plate electrode 600x600x 6.3mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate is not less than 1.5 mtr below normal ground level connected to galvanized iron strips 32x6mm with GI pipe, nuts, bolts and washers complete upto and including test point made out of 40x3mm GI flat, PCC pit of required size in PCC 1:2:4 type B1 and RCC cover with frame, charcoal, common salt 15cm at round the earth plate watering pipe 20mm med grade/galvanized and 40mm dia GI pipe light grade for GI strip protectetion, funnel with wire mesh including testing on completion, complete all as specified and directed as shown in electrical plate No 3 of SSR Part-I 2009. (Note: The unit rate includes earth strip and protection pipe upto (maximum 7.5 metre from earth plate) earth point/test point.
Exc in trenches not exc. 1.5 m wide and not exc. 1.5 in depth for cable laying, foundation of poles, stay assy etc. and getting out in hard / dense soil /PCC/Road cutting complete all as specified and directed
Excavation in trenches not exc. 1.5 m wide and exc. 1.5 in depth for foundation of poles, stay assy etc. and getting out in any type of soil complete all as specified and directed
Returning filling in including spreading levelling watering and well ramming in layers not exc. 25 cm thick each complete all as specified and directed
Removing excavated material to a distance not exc. 50 mtr and depositing where directed at a level not exc. 1.5 mtr above the starting point of any type of soil complete all as specified and directed
Dry sand cushioning to UG cable 8 cm thick before laying and 15cm thick after laying complete all as specified and directed. Note:- 1.Dry fine sand of best available quality shall be used. 2.Punned thickness shall be made and paid.
Brick covering with width equal to length of brick as the mechanical protction to cable with well burned sub class 'B' laid in trenches flat complete all as specified and directed.
Plain cement concrete (PCC) type C2 1:3:6 using 40mm graded crushed stone aggregate for making foundation of Pole/stay assembly ,filling and mass concrete, complete all as specified and directed.
Plain cement concrete (PCC) type B- 1:2:4 using 20mm graded crushed stone aggregate for making copings of Poles etc. With & including necessary form work, complete all as specified and directed.
Supply, installation, commisioning and testing out door type LT Panel of suitable size, made out of mild steel CRCA sheet of 3.15 mm thick with angle iron frame of size 50mm x 50mm x 6mm with canopy top, two side ventilators, front openable hinged, double door shutters with locking arrangement, weather & vermin proof suitable for working on 440 volts AC supply including bus bar chamber and aluminium bus bar of suitable size 4 Nos mounted on hygroscopic insulators fixed in separate bus bar chamber and seperate compartment for incomming and outgoing feeder, all pre wired with suitable size of copper conductor cable including painted with two coats of powder coated paint over a coat of red oxide zinc chrome primer on out side surface and two coats of synthetic enamel paint over a coat of red oxide zinc chromate primer on internal surfaces including provision of lugs and cable gland for housing with the following fitment accessories as mentioned below:- Note-Panel shall be approved by CPRI . .....contd to item No-33.01 to 33.08
a) Aluminium bus bar capacity 200 Amps for Phase-R-Y-B-3 Nos & 100 Amps for neutral -1 No
b) Incomming MCCB 4 pole 25 KA 100 Amps - 1 No With ICS=ICU=100%.
c) On Load Changeover Switch 415 Volts, 100 Amp 4 pole -01 No
d) Outgoing MCCB TPN 25 KA 63 Amps - 2 Nos With ICS=ICU=100%. (Spare)
e) MCB SPN 10 KA 32 Amps - 2 Nos
h) One set indicator lamp for R,Y & B for each phase
M/S NARAYAN CONSTRUCTION
M/S PARSHOTAM KUMAR GUPTA
M/S KIRAN CONSTRUCTIONS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .